Air Conditioning

Technical Data

FCAG-B

> FCAG35BVEB
> FCAG50BVEB
> FCAG60BVEB
> FCAG71BVEB
> FCAG100BVEB
> FCAG125BVEB
> FCAG140BVEB
• Indoor Unit • FCAG-B

TABLE OF CONTENTS
FCAG-B

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Safety device settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Dimensional Drawings with Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Dimensional Drawings with Fresh Air Intake . . . . . . . . . . . . . . . . . . . . . . . . 10
6 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
7 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

8 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Sound Pressure Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

10 Air flow patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18


Air Flow Pattern - Cooling / Heating . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . 18

• Split - Sky Air • FCAG-B 1


• Indoor Unit • FCAG-B

1 Features

c yt kwi Son Ul - f rB tod- oinG dluA nCpo 360°


FSIR air discharge for optimum efficiency and comfort
• Unified indoor unit can be combined with R-32 and R-410A outdoor • Lowest installation height in the market: 214mm for class 20-63
units, symplifying stock • Widest choice ever in decoration panels: designer panels in white
• Combining with R-32 Bluevolution technology, reduces (RAL9010) and black (RAL9005) and standard panels in white
environmental impact with 68% compared to R-410A, leads directly (RAL9010) with grey louvers or full white
to lower energy consumption thanks to its high energy efficiency and • Bigger flaps and unique swing pattern improve equal air distribution
1 has up to lower 16% refrigerant charge
• 5 different fan speeds available for maximum comfort
• Optional automatic filter cleaning panel results in higher efficiency &
comfort and lower maintenance costs. 2 filters available: standard • Optional fresh air intake
filter and finer mesh filter • Branch duct discharge allows to optimize air distribution in irregular
• Two optional intelligent sensors improve energy efficiency and shaped rooms or to supply air to small adjacent rooms
comfort • Standard drain pump with 675mm lift increases flexibility and
• Individual flap control: flexibility to suit every room layout without installation speed
changing the location of the unit!

Infrastructure Presence & Home leave Fan only Auto-cleaning Draught Auto cooling- Whisper quiet Ceiling soiling
cooling floor sensor operation filter prevention heating prevention
changeover

Individual flap Vertical auto Fan speed Dry programme Air filter Weekly timer Infrared remote Wired remote Centralised
control swing steps control control control

Online Auto-restart Self diagnosis Drain pump kit Twin/triple/ Multi model
controller via double twin application
app application

2 • Split - Sky Air • FCAG-B


• Indoor Unit • FCAG-B

2 Specifications

2-1 Technical Specifications


Casing Material
FCAG35B FCAG50B FCAG60B FCAG71B FCAG100B
Galvanised steel plate
FCAG125B FCAG140B 3
Dimensions Unit Height/Width/ mm 204/840/840 246/840/840
Depth
Packed unit Height/Width/ mm 220/882/882 260/882/882
Depth
Weight Unit kg 18 19 21 23
2
Packed unit kg 20 21 23 26
Decoration panel Model BYCQ140E2W1 / BYCQ140E2W1W / BYCQ140E2W1B
Dimensions HeightxWidthxDe mm 65x950x950
pth
Weight kg 5.5
Decoration panel 2 Model BYCQ140E2GFW1 / BYCQ140E2GFW1B
Dimensions HeightxWidthxDe mm 148x950x950
pth
Weight kg 10.3
Decoration panel 3 Model BYCQ140E2P / BYCQ140E2PB
Dimensions HeightxWidthxDe mm 106x950x950
pth
Weight kg 6.5
Heat exchanger Inside length mm 2,134 2,090
Outside length mm 2,181 2,184
Rows Quantity 2 3
Fin pitch mm 1.20
Passes Quantity 4 6 12 14
Face area m² 0.278 0.366 0.371 0.464 0.464 0.464
Stages Quantity 9 12 15
Empty tubeplate Quantity 0
hole
Tube type Ø5 HI-XA
Fin Type Cross fin coil (multi slit fins and hi-XA tubes)
Air filter Type Resin net
Fan Type Turbo fan
Quantity 1
Air flow rate Cooling High m³/min 12.9 14.6 14.9 15.1 22.7 27.2
cfm 446 516 526 533 802 961
Mediu m³/min 10.6 11.8 12.2 13.0 17.8 20.4
m cfm 374 417 431 456 629 720
Low m³/min 8.8 9.4 9.6 10.8 13.0 13.1
cfm 311 332 339 381 459 463
Heating High m³/min 14.1 14.6 14.9 15.1 23.0 27.0
cfm 498 516 526 533 812 954
Mediu m³/min 11.6 11.8 12.2 12.9 18.1 20.2
m cfm 410 417 431 456 639 713
Low m³/min 9.4 9.6 10.8 13.2 13.0
cfm 332 339 381 466 459
Fan motor Quantity 1
Model DFB05A2VB DFB11A2VB
Speed Steps 5
Output High W 48 106
Sound power level Cooling dBA 49.0 51.0 54.0 58.0
Heating dBA 49.0 51.0 54.0 58.0
Sound pressure level Cooling High/Medium/ dBA 31.0/29.0/27.0 33.0/31.0/ 35.0/31.0/ 37.0/33.0/ 41.0/35.0/29.0
Low 28.0 28.0 29.0
Heating High/Medium/ dBA 31.0/29.0/27.0 33.0/31.0/28.0 37.0/33.0/ 41.0/35.0/29.0
Low 29.0
Control systems Infrared remote control BRC7FA532F / BRC7FB532F / BRC7FA532FB / BRC7FB532FB
Wired remote control BRC1D528 / BRC1E53A7 / BRC1E53B7 / BRC1E53C7 / BRC1H81W/S / BRC1H51(9W/S/K7 /
BRC2E52C7 / BRC3E52C7
Refrigerant Type R-32 / R-410A

• Split - Sky Air • FCAG-B 3


• Indoor Unit • FCAG-B

2 Specifications

2-1 Technical Specifications FCAG35B FCAG50B FCAG60B FCAG71B FCAG100B FCAG125B FCAG140B
Piping connections Sound absorbing insulation Foamed polyurethane
Liquid Type/OD mm Flare connection/6,35 Flare connection/9,52
Gas Type/OD mm Flare Flare connection/12.70 Flare connection/15.90
connection/
9.52
2 Drain VP25 (O.D. 32 / I.D. 25)
Heat insulation Foamed polystyrene / Foamed polyethylene
Safety devices Item 01/02 PC board fuse/Fan motor overcurrent protector -/Fan motor overcurrent protector
Standard Accessories : Operation manual; Quantity : 1;
Standard Accessories : Installation manual; Quantity : 1;
Standard Accessories : Drain hose; Quantity : 1;
Standard Accessories : Clamp for drain hose; Quantity : 1;
Standard Accessories : Washer for hanger bracket; Quantity : 8;
Standard Accessories : Screws; Quantity : 4;
Standard Accessories : Installation guide; Quantity : 1;
Standard Accessories : Insulation for fitting; Quantity : 2;
Standard Accessories : Sealing pads; Quantity : 1;
Standard Accessories : Wire clamp material; Quantity : 7;
Standard Accessories : Clamps; Quantity : 1;

2-2 Electrical Specifications FCAG35B FCAG50B FCAG60B FCAG71B FCAG100B FCAG125B FCAG140B
Power supply Phase 1~
Frequency Hz 50/60
Voltage V 220-240/220
Notes

The sound power level is an absolute value indicating the power which a sound source generates.
The BYCQ140E2W1W has white insulations. Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the
BYCQ140E2W1W decoration panel in enviroments exposed to concentrations of dirt.
BYCQ140E2W1: pure white standard panel with grey louvers; BYCQ140E2W1W: pure white standard panel with white louvers; BYCQ140E2W1B: black standard panel with black
louvers.

4 • Split - Sky Air • FCAG-B


• Indoor Unit • FCAG-B

3 Safety device settings


3-1 Safety Device Settings

&'Ͳ 3

^ĂĨĞƚLJĚĞǀŝĐĞƐ &'ϯϱͲϳϭs &'ϭϬϬͲϭϰϬs


WĨƵƐĞ ϮϱϬs͕ϯ͘ϭϱ ͲͲͲ
&ĂŶŵŽƚŽƌŽǀĞƌĐƵƌƌĞŶƚƉƌŽƚĞĐƚŝŽŶ EŽŵŝŶĂů Ϭ͕ϵϮ ϭ͕ϰϵ
&ĂŶŵŽƚŽƌƚŚĞƌŵĂůƉƌŽƚĞĐƚŽƌ DĂdžŝŵƵŵ ͲͲͲ ͲͲͲ
ƌĂŝŶƉƵŵƉĨƵƐĞ ͲͲͲ ͲͲͲ

^ĂĨĞƚLJĚĞǀŝĐĞƐ &,'ϳϭͲϭϰϬ,s
WĨƵƐĞ ͲͲͲ
&ĂŶŵŽƚŽƌŽǀĞƌĐƵƌƌĞŶƚƉƌŽƚĞĐƚŝŽŶ EŽŵŝŶĂů ϭ͕ϰϵ
&ĂŶŵŽƚŽƌƚŚĞƌŵĂůƉƌŽƚĞĐƚŽƌ DĂdžŝŵƵŵ ͲͲͲ
ƌĂŝŶƉƵŵƉĨƵƐĞ ͲͲͲ

ϰϭϮϭϲϵϬ

• Split - Sky Air • FCAG-B 5


• Indoor Unit • FCAG-B

4 Options
4-1 Options

&'Ͳ ǀĂŝůĂďŝůŝƚLJ

&,'ϳϭͲ
ϭϰϬ,s
ϭϰϬs

ϭϮϱs
&'ϯϱͲ

&y&YϮϬͲ
KƉƚŝŽŶŬŝƚ WƌŽĚƵĐƚŶĂŵĞ

^ƚĂŶĚĂƌĚ zYϭϰϬϮtϭ ‫ض‬ ‫ض‬


ĞĐŽƌĂƚŝŽŶƉĂŶĞů tŚŝƚĞ zYϭϰϬϮtϭt䷶ ‫ض‬ ‫ض‬
4 ůĂĐŬ zYϭϰϬϮtϭ ‫ض‬ ‫ض‬
ĞƐŝŐŶĞƌĚĞĐŽƌĂƚŝŽŶƉĂŶĞů zYϭϰϬϮW ‫ض‬ ‫ض‬
ĞƐŝŐŶĞƌĚĞĐŽƌĂƚŝŽŶƉĂŶĞů ůĂĐŬ zYϭϰϬϮW ‫ض‬ ‫ض‬
^ĞůĨͲĐůĞĂŶŝŶŐĚĞĐŽƌĂƚŝŽŶƉĂŶĞů;ǁŝƚŚĨŝŶĞĨŝůƚĞƌͿ zYϭϰϬϮ'&tϭ䷷䷸䢢䢢䢢 ‫ض‬ ‫ض‬
^ĞůĨͲĐůĞĂŶŝŶŐĚĞĐŽƌĂƚŝŽŶƉĂŶĞů;ǁŝƚŚĨŝŶĞĨŝůƚĞƌͿ ůĂĐŬ zYϭϰϬϮ'&tϭ䷷䷸ ‫ض‬ ‫ض‬
>ŽŶŐͲůŝĨĞƌĞƉůĂĐĞŵĞŶƚĨŝůƚĞƌ <&Wϱϱϭ<ϭϲϬ ‫ض‬ ‫ض‬
ŚĂŵďĞƌ΀ƉĂƌƚŽĨĨƌĞƐŚĂŝƌŝŶƚĂŬĞŬŝƚ;ͼϮϬͼйĨƌĞƐŚĂŝƌͿ΁ <WϱϱϭϲϬͲϭ䷺䷻ ‫ض‬ ‫ض‬
ŝĨĨƵƐĞƌĨƌŽŵĐŚĂŵďĞƌƚŽĚƵĐƚ΀ƉĂƌƚŽĨĨƌĞƐŚĂŝƌŝŶƚĂŬĞŬŝƚ;ͼϮϬͼйĨƌĞƐŚĂŝƌͿ΁ <WϱϱϭϲϬͲϮ䷺䷻ ‫ض‬ ‫ض‬
ŝƌĚŝƐĐŚĂƌŐĞŽƵƚůĞƚƐĞĂůŝŶŐŵĞŵďĞƌ <,YϱϲϭϰϬ䷺ ‫ض‬ ‫ض‬
^ĞŶƐŽƌŬŝƚ ZzYϭϰϬϴ䷼ ‫ض‬ ‫ض‬
^ĞŶƐŽƌŬŝƚ ůĂĐŬ ZzYϭϰϬϴ䷽ ‫ض‬ ‫ض‬
^ĞŶƐŽƌŬŝƚ;ĨŽƌĚĞƐŝŐŶĞƌĚĞĐŽƌĂƚŝŽŶƉĂŶĞůͿ ZzYϭϰϬϴ兺 ‫ض‬ ‫ض‬
^ĞŶƐŽƌŬŝƚ;ĨŽƌĚĞƐŝŐŶĞƌĚĞĐŽƌĂƚŝŽŶƉĂŶĞůͿ ůĂĐŬ ZzYϭϰϬϴ养 ‫ض‬ ‫ض‬
džƚĞŶƐŝŽŶǁŝƌĞŚĂƌŶĞƐƐ t,Zϭ典 ‫ض‬
tŝƌĞůĞƐƐƌĞŵŽƚĞĐŽŶƚƌŽů Zϳ&ϱϯϮ&䷺䷾兼 ‫ض‬ ‫ض‬
tŝƌĞůĞƐƐƌĞŵŽƚĞĐŽŶƚƌŽů ůĂĐŬ Zϳ&ϱϯϮ&䷺䷿फ ‫ض‬ ‫ض‬
tŝƌĞůĞƐƐƌĞŵŽƚĞĐŽŶƚƌŽů;ĨŽƌĚĞƐŝŐŶĞƌĚĞĐŽƌĂƚŝŽŶƉĂŶĞůͿ Zϳ&ϱϯϮ&䷺兺फ ‫ض‬ ‫ض‬
tŝƌĞůĞƐƐƌĞŵŽƚĞĐŽŶƚƌŽů;ĨŽƌĚĞƐŝŐŶĞƌĚĞĐŽƌĂƚŝŽŶƉĂŶĞůͿ ůĂĐŬ Zϳ&ϱϯϮ&䷺养फ ‫ض‬ ‫ض‬
tŝƌĞĚƌĞŵŽƚĞĐŽŶƚƌŽů ZϭϱϮϴ一फ ‫ض‬ ‫ض‬
tŝƌĞĚƌĞŵŽƚĞĐŽŶƚƌŽů Zϭ,ϴϭtͬ^ϳ ‫ض‬

Zϭϱϯϳ丁͕Zϭϱϯϳ丂͕
tŝƌĞĚƌĞŵŽƚĞĐŽŶƚƌŽů ‫ض‬ ‫ض‬
Zϭϱϯϳ七丄͕Zϭ,ϱϭ;ϵͿtͬ<ͬ^ϳ

^ŝŵƉůŝĨŝĞĚƌĞŵŽƚĞĐŽŶƚƌŽů;ǁŝƚŚŽƉĞƌĂƚŝŽŶŵŽĚĞƐĞůĞĐƚŽƌďƵƚƚŽŶͿ ZϮϱϮϳ丄丅फ ‫ض‬ ‫ض‬


^ŝŵƉůŝĨŝĞĚƌĞŵŽƚĞĐŽŶƚƌŽů;ǁŝƚŚŽƵƚŽƉĞƌĂƚŝŽŶŵŽĚĞƐĞůĞĐƚŽƌďƵƚƚŽŶͿ ZϯϱϮϳ丄丅फ ‫ض‬ ‫ض‬
tŝƌŝŶŐĂĚĂƉƚŽƌĨŽƌĞůĞĐƚƌŝĐĂůĂƉƉĞŶĚŝĐĞƐͼϭͼ <ZWϭϱϴ䷺丆 ‫ض‬ ‫ض‬
tŝƌŝŶŐĂĚĂƉƚŽƌĨŽƌĞůĞĐƚƌŝĐĂůĂƉƉĞŶĚŝĐĞƐͼϮͼ <ZWϰϱϯ䷺丆万 ‫ض‬ ‫ض‬
tŝƌŝŶŐĂĚĂƉƚŽƌ;ŚŽƵƌŵĞƚĞƌͿ <ZWϭϭϮ䷺丆 ‫ض‬ ‫ض‬
ZĞŵŽƚĞƐĞŶƐŽƌ <Z^ϬϭͲϳ ‫ض‬ ‫ض‬
/ŶƐƚĂůůĂƚŝŽŶďŽdžĨŽƌĂĚĂƉƚŽƌW <ZWϭ,ϵϴ䷺ ‫ض‬ ‫ض‬
ĞŶƚƌĂůƌĞŵŽƚĞĐŽŶƚƌŽů ^ϯϬϮϱϭ ‫ض‬ ‫ض‬
hŶŝĨŝĞĚKEͬK&&ĐŽŶƚƌŽůůĞƌ ^ϯϬϭϱϭ ‫ض‬ ‫ض‬
ůĞĐƚƌŝĐĂůďŽdžǁŝƚŚĞĂƌƚŚƚĞƌŵŝŶĂů;ͼϮͼďůŽĐŬƐͿ <:ϮϭϮ ‫ض‬ ‫ض‬
ůĞĐƚƌŝĐĂůďŽdžǁŝƚŚĞĂƌƚŚƚĞƌŵŝŶĂů;ͼϯͼďůŽĐŬƐͿ <:ϯϭϭ ‫ض‬ ‫ض‬
^ĐŚĞĚƵůĞƚŝŵĞƌ ^dϯϬϭϱϭ ‫ض‬ ‫ض‬
WĨŽƌŵƵůƚŝͲƚĞŶĂŶƚŝŶĚŽŽƌƵŶŝƚƐ dϭϭϰϲϭ ‫ض‬
ŝdŽƵĐŚŽŶƚƌŽůůĞƌ ^ϲϬϭϱϭ ‫ض‬
ŝŐŝƚĂůŝŶƉƵƚĂĚĂƉƚŽƌ ZWϳϱϯ丈 ‫ض‬ ‫ض‬
tŝͲ&ŝĂĚĂƉƚŽƌĨŽƌƐŵĂƌƚƉŚŽŶĞƐ ZWϬϲϵϴϮ具典兹 ‫ض‬
/ŶƚĞůůŝŐĞŶƚdŽƵĐŚDĂŶĂŐĞƌ DϲϬϭϱϭ ‫ض‬ ‫ض‬
/ŶƚĞůůŝŐĞŶƚdĂďůĞƚŽŶƚƌŽůůĞƌ ϲϬϭϱϭ ‫ض‬ ‫ض‬
EŽƚĞƐ
䷵ ůůŽƉƚŝŽŶƐĂƌĞŬŝƚƐ
䷶ dŚŝƐŽƉƚŝŽŶŚĂƐǁŚŝƚĞŝŶƐƵůĂƚŝŽŶ͘
ĞĂǁĂƌĞƚŚĂƚĚŝƌƚĨŽƌŵĂƚŝŽŶŝƐŵŽƌĞĞĂƐŝůLJǀŝƐŝďůĞŽŶǁŚŝƚĞŝŶƐƵůĂƚŝŽŶ͘
/ƚŝƐƌĞĐŽŵŵĞŶĚĞĚŶŽƚƚŽŝŶƐƚĂůůƚŚŝƐŽƉƚŝŽŶŝŶĞŶǀŝƌŽŶŵĞŶƚƐǁŝƚŚĂŚŝŐŚĐŽŶĐĞŶƚƌĂƚŝŽŶŽĨĚŝƌƚ͘
䷷ dŽďĞĂďůĞƚŽĐŽŶƚƌŽůŽƉƚŝŽŶͼzYϭϰϬϮ'&tϭͬzYϭϰϬϮ'&tϭͼ͕ĐŽŶƚƌŽůůĞƌͼZϭͬZϭ,ͼŝƐƌĞƋƵŝƌĞĚ͘
䷸ KƉƚŝŽŶͼzYϭϰϬϮ'&tϭͬzYϭϰϬϮ'&tϭͼĐĂŶŶŽƚďĞƵƐĞĚǁŝƚŚͼsZs/sͲ^ͼ͕ŵƵůƚŝ͕ĂŶĚŶŽŶͲŝŶǀĞƌƚĞƌƐƉůŝƚŽƵƚĚŽŽƌƵŶŝƚƐ͘
䷹ Note not applicable anymore
͘
䷺ dŚŝƐŽƉƚŝŽŶĐĂŶŶŽƚďĞĐŽŵďŝŶĞĚǁŝƚŚͼzYϭϰϬϮ'&tϭͬzYϭϰϬϮ'&tϭͼ͘
䷻ ŽƚŚƉĂƌƚƐŽĨƚŚĞĨƌĞƐŚĂŝƌŝŶƚĂŬĞŬŝƚĂƌĞƌĞƋƵŝƌĞĚĨŽƌĞĂĐŚƵŶŝƚ͘
䷼ KŶůLJƉŽƐƐŝďůĞŝŶĐŽŵďŝŶĂƚŝŽŶǁŝƚŚͼzYϭϰϬϮtϭͬzYϭϰϬϮtϭtͬzYϭϰϬϮ'&tϭͼ
䷽ KŶůLJƉŽƐƐŝďůĞŝŶĐŽŵďŝŶĂƚŝŽŶǁŝƚŚͼzYϭϰϬϮtϭͬzYϭϰϬϮ'&tϭͼ
䷾ KŶůLJƉŽƐƐŝďůĞŝŶĐŽŵďŝŶĂƚŝŽŶǁŝƚŚͼzYϭϰϬϮtϭͬzYϭϰϬϮtϭtͼ
䷿ KŶůLJƉŽƐƐŝďůĞŝŶĐŽŵďŝŶĂƚŝŽŶǁŝƚŚͼzYϭϰϬϮtϭͼ
一 EŽƚƌĞĐŽŵŵĞŶĚĞĚďĞĐĂƵƐĞŽĨŝƚƐůŝŵŝƚĞĚĨƵŶĐƚŝŽŶĂůŝƚLJ͘
丁 /ŶĐůƵĚĞĚůĂŶŐƵĂŐĞƐĂƌĞ͗ŶŐůŝƐŚ͕'ĞƌŵĂŶ͕&ƌĞŶĐŚ͕/ƚĂůŝĂŶ͕^ƉĂŶŝƐŚ͕WŽƌƚƵŐƵĞƐĞ͕ĂŶĚƵƚĐŚ͘
丂 /ŶĐůƵĚĞĚůĂŶŐƵĂŐĞƐĂƌĞ͗ŶŐůŝƐŚ͕njĞĐŚ͕ƌŽĂƚŝĂŶ͕,ƵŶŐĂƌŝĂŶ͕^ůŽǀĞŶŝĂŶ͕ZŽŵĂŶŝĂŶ͕ĂŶĚƵůŐĂƌŝĂŶ͘
七 /ŶĐůƵĚĞĚůĂŶŐƵĂŐĞƐĂƌĞ͗ŶŐůŝƐŚ͕ZƵƐƐŝĂŶ͕'ƌĞĞŬ͕dƵƌŬŝƐŚ͕WŽůŝƐŚ͕ůďĂŶŝĂŶ͕ĂŶĚ^ůŽǀĂŬ͘
丄 >ĂŶŐƵĂŐĞƉĂĐŬͼϯͼŽĨĐŽŶƚƌŽůůĞƌͼZϭϱϯϳͼŝƐĚŝĨĨĞƌĞŶƚĨƌŽŵƚŚĂƚŽĨĐŽŶƚƌŽůůĞƌͼZϮͬϯϱϮϳͼ͘
丅 /ŶĐůƵĚĞĚůĂŶŐƵĂŐĞƐĂƌĞ͗
>ĂŶŐƵĂŐĞƉĂĐŬͼϭͼ͗ŶŐůŝƐŚ͕'ĞƌŵĂŶ͕&ƌĞŶĐŚ͕ƵƚĐŚ͕^ƉĂŶŝƐŚ͕/ƚĂůŝĂŶ͕ĂŶĚWŽƌƚƵŐƵĞƐĞ͘
tŝƚŚWĐĂďůĞͼ<WϯͼŝŶĐŽŵďŝŶĂƚŝŽŶǁŝƚŚƚŚĞhƉĚĂƚĞƌWƐŽĨƚǁĂƌĞ͕LJŽƵĐĂŶĂĚĚŝƚŝŽŶĂůůLJĐŚĂŶŐĞƚŚĞůĂŶŐƵĂŐĞƚŽ͗
>ĂŶŐƵĂŐĞƉĂĐŬͼϮͼ͗ŶŐůŝƐŚ͕ƵůŐĂƌŝĂŶ͕ƌŽĂƚŝĂŶ͕njĞĐŚ͕,ƵŶŐĂƌŝĂŶ͕ZŽŵĂŶŝĂŶ͕ĂŶĚ^ůŽǀĞŶŝĂŶ͘
>ĂŶŐƵĂŐĞƉĂĐŬͼϯͼ͗ŶŐůŝƐŚ͕'ƌĞĞŬ͕WŽůŝƐŚ͕ZƵƐƐŝĂŶ͕^ĞƌďŝĂŶ͕^ůŽǀĂŬ͕ĂŶĚdƵƌŬŝƐŚ͘
丆 ZĞƋƵŝƌĞƐŝŶƐƚĂůůĂƚŝŽŶďŽdžĨŽƌĂĚĂƉƚŽƌWͼ<ZWϭ,ϵϴͼ͘
万 dŚŝƐŽƉƚŝŽŶĐĂŶŶŽƚďĞĐŽŵďŝŶĞĚǁŝƚŚͼZWϬϲϵϴϮͼ͘
丈 KŶůLJƉŽƐƐŝďůĞŝŶĐŽŵďŝŶĂƚŝŽŶǁŝƚŚƌĞŵŽƚĞĐŽŶƚƌŽůͼZϮͬϯϱϮϳ͕Zϭϱϯͬͬϳ͕Zϭ,ϱϭ;ϵͿtͬ<ͬ^ϳ͕Zϭ,ϴϭtͬ^ϳͼ͘
具 KŶůLJƉŽƐƐŝďůĞŝŶĐŽŵďŝŶĂƚŝŽŶǁŝƚŚǁŝƌĞĚŽƌǁŝƌĞůĞƐƐƌĞŵŽƚĞĐŽŶƚƌŽů;Ğ͘Ő͘ͼZϭ͕Zϭ,͕Zϳ&ͼͿ
典 tŚĞŶĐŽŵďŝŶŝŶŐƚŚĞtŝͲ&ŝĂĚĂƉƚŽƌ;ͼZWϬϲϵϴϮͼͿǁŝƚŚĂƐĞůĨͲĐůĞĂŶŝŶŐĚĞĐŽƌĂƚŝŽŶƉĂŶĞů;ͼzYϭϰϬϮ'&tϭͬzYϭϰϬϮ'&tϭͼͿ͕ŽƉƚŝŽŶ
ͼt,ZϭͼŝƐƌĞƋƵŝƌĞĚ͘
兹 dŚŝƐŽƉƚŝŽŶĐĂŶŶŽƚďĞĐŽŵďŝŶĞĚǁŝƚŚͼ<ZWϰϱϯͼ͘
兺 KŶůLJƉŽƐƐŝďůĞŝŶĐŽŵďŝŶĂƚŝŽŶǁŝƚŚͼzYϭϰϬϮWͼ
养 KŶůLJƉŽƐƐŝďůĞŝŶĐŽŵďŝŶĂƚŝŽŶǁŝƚŚͼzYϭϰϬϮWͼ
兼 dŚĞĂĐƚŝǀĞĂŝƌĨůŽǁĐŝƌĐƵůĂƚŝŽŶĨƵŶĐƚŝŽŶŝƐŶŽƚĂǀĂŝůĂďůĞĨŽƌƚŚŝƐĐŽŶƚƌŽůůĞƌ͘ ϯϭϮϭϳϬϰ
6 • Split - Sky Air • FCAG-B
• Indoor Unit • FCAG-B

5 Dimensional drawings
5-1 Dimensional Drawings

&'Ͳ
Notes
3
 Location of nameplate
The unit nameplate is located on the control box cover.
The decoration panel nameplate is located on the piping-side panel frame, under the corner cover.
 When installing optional accessories, refer to their respective documentation.
 Make sure the distance between the ceiling and the cassette does not exceed ·35·mm.
The maximum ceiling opening is ·910·mm.
 When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam,
 thickness •·10·mm). When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit.
 When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller.
·300· or less

See note
㻌㻌㻌㻌㻌㻌㻌㻌㻌㻌㻌 ·5·. 㻢

5
㻠㻞㻜
Drain 㻌side
㻰㻱㼀㻭㻵㻸㻌㻌㻭 㻰㻱㼀㻭㻵㻸㻌㻭
·2· places ·2· places

See note ·3·.


Suspension position
Opposite side Opposite side
㻢㻣 㻥㻢㻚㻡
㻥 㻭 㻡㻠㻚㻡 㻡㻠㻚㻡 㻥㻢㻚㻡
㻡㻟

㻤㻜
㻤㻢㻜㻙㻥㻝㻜

㻤㻜
㻥㻡㻜
㻣㻤㻜

㻝㻜㻜
㻝㻜㻜
㻞㻡㻚㻠

㻞㻡㻚㻠
㻞㻝㻟
Ceiling opening

㻝㻞㻝㻚㻡

㻝㻞㻝㻚㻡
㻟㻡㻜

㻟㻡㻜
㻝㻜㻜

㻝㻜㻜
 㻣㻡

㻝㻜

㻤㻜

㻤㻜
㻥㻡
㻠㻞㻜 㻭㻮 Piping side

See
㻌㻌㻌 note ·6·. )&$*%9(%
㻣㻝㻜 㻥㻡㻜 )&$*%9(%
Suspension position
)&$+*+9(% );)4%9(%
㻤㻢㻜㻙㻥㻝㻜 㻤㻠㻜
);)4%9(%
Ceiling opening See note ·3·.
Adjustable

㻡㻡 㻤㻠㻜 㻡㻡
㻟㻠㻜
㻰㻱㼀㻭㻵㻸㻌㻌㻮 㻰㻱㼀㻭㻵㻸㻌㻮
㻠 㻝 㻞 ·2· places ·2· places
㻜㻙㻢㻣㻡


Opposite side Opposite side
Required installation space
㻝㻟㻜

㻟㻡㻜
㻟㻡㻜
㻯 㻝㻞㻝㻚㻡 㻝㻞㻝㻚㻡

㻭㻭
㻝㻣㻡

㻝㻡㻜
㻝㻜

㻝㻝㻜

㻥㻢㻚㻡 㻡㻠㻚㻡 㻡㻠㻚㻡

㻥㻡

㻡㻟
㻢㻣
·2700· or more

㻠㻜

㻟㻡 㻮 㻟㻡 㻞㻤㻜 㻤㻝 㻝㻜㻜 㻝㻜㻜 㻤㻡

㻥㻢㻚㻡
See note ·3·. 㻡 㻤㻝 㻝㻜㻜 㻝㻜㻜 㻤㻡
See note ·3·. OR
㻠㻌㻙㻌㻹㻤㻌㻌㻌㻌㻌㻌㻌㻌㻹㻝㻜 㻟㻟㻜
Suspension bolt
)&$*%9(% )&$*%9(%
㻭㻾㻾㻻㼃㻌㼂㻵㻱㼃㻌㻯 )&$+*+9(% );)4%9(%
);)4%9(%

Respect the distances shown on the figure. Item Name


·1500· or more 㻝 Liquid pipe connection port
Ceiling-mounted lighting Air fan ·200· or more 㻞 Gas pipe connection port
Other unit
㻟 Drain pipe connection
·1500· or more ·1500· or more
㻠 Power supply wiring intake
·200· or more 㻡 Transmission wiring intake hole
·1500· or more
·1500· or more 㻢 Air discharge outlet
·2000· or more
·4000· or more
Required installation space 㻣 Air suction grille
㻤 Corner decoration cover
If a discharge outlet is closed up with the "sealing member" option kit, then the required
installation space on that (closed up) side is ·500·mm instead of ·1500·mm. 㻥 Drain hose
㻝㻜 Knockout hole. ϮϭϮϭϲϱϱ
&'Ͳ
Notes
 Location of nameplate
The unit nameplate is located on the control box cover.
The decoration panel nameplate is located on the piping-side panel frame, under the corner cover.
 When installing optional accessories, refer to their respective documentation.
 Make sure the distance between the ceiling and the cassette does not exceed ·35·mm.
The maximum ceiling opening is ·910·mm.
 When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness •·10·mm).
 When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit.
·300· or less See
㻌 note ·5·. 㻣 㻢 㻤 Drain side
㻌㻌㻌㻌㻌㻌㻌
㻠㻞㻜
See note ·3·.

㻰㻱㼀㻭㻵㻸㻌㻌㻭 㻰㻱㼀㻭㻵㻸㻌㻭
Suspension position

㻥 ·2· places
㻭 ·2· places
Opposite side
Opposite side 㻢㻣 㻥㻢㻚㻡
㻤㻢㻜㻙㻥㻝㻜

㻡㻟
㻥㻡㻜
㻣㻤㻜

㻡㻠㻚㻡㻡㻠㻚㻡 㻥㻢㻚㻡
㻞㻝㻟
Ceiling opening

㻤㻜

㻤㻜
㻞㻡㻚㻠

㻝㻜㻜
㻝㻜㻜

㻞㻡㻚㻠

 㻣㻡
㻝㻞㻝㻚㻡

㻝㻞㻝㻚㻡
㻟㻡㻜

㻟㻡㻜

㻝㻜
㻝㻜㻜

㻝㻜㻜

㻠㻞㻜 㻭㻮
㻤㻜

㻤㻜

㻣㻝㻜 Piping side


Suspension position 㻥㻡㻜
㻥㻡
㻤㻢㻜㻙㻥㻝㻜
Adjustable

Ceiling opening See note ·3·. 㻤㻠㻜 㻰㻱㼀㻭㻵㻸㻌㻌㻮 )&$*%9(% )&$*%9(%


)&$+*+9(% );)4%9(%
㻜㻙㻢㻣㻡

㻡㻡 㻤㻠㻜 㻡㻡 㻟㻠㻜 㻝 ·2· places


㻠 㻞 );)4%9(%
㻟 Opposite side
㻞㻝㻜

㻟㻡㻜
Required installation space

㻝㻞㻝㻚㻡
㻭㻭
㻞㻡㻡

㻡㻠㻚㻡
㻞㻟㻜
㻝㻥㻜

㻥㻡
㻥㻢㻚㻡 㻡㻠㻚㻡


㻥㻜


·2700· or more

㻞㻤㻜 㻤㻝 㻝㻜㻜 㻝㻜㻜 㻤㻡


㻠㻜

㻟㻡 㻡 㻟㻡 㻠㻌㻙㻌㻹㻤㻌㻌㻌㻌㻌㻌
OR 㻌㻌㻌㻹㻝㻜
㻟㻟㻜
Suspension bolt
See note ·3·. See note ·3·.
㻭㻾㻾㻻㼃㻌㼂㻵㻱㼃㻌㻯 )&$*%9(%
·1500· or more )&$+*+9(%
);)4%9(%
·200· or more

·1500· or more ·1500· or more


Ceiling-mounted lighting
Air fan Other unit
·200· or more
㻰㻱㼀㻭㻵㻸㻌㻮
·1500· or more ·2· places Item Name
㻝 Liquid pipe connection port
㻔㻖㻞㻕 㻔㻖㻟㻕 㻔㻖㻝㻕 Required installation space Opposite side
If a discharge outlet is closed up with the "sealing member" option kit, then the required 㻞 Gas pipe connection port
㻞㻡㻢 㻟㻡㻜
installation space on that (closed up) side is ·500·mm instead of ·1500·mm. 㻝㻞㻝㻚㻡 㻟 Drain pipe connection
·1500· or more
㻠 Power supply wiring intake
Dust opening

·2000· or more
㻡 Transmission wiring intake
·4000· or more
㻡㻟
㻢㻣

㻢 hole Air discharge outlet


㻝㻜㼻㻝㻜㼻 㻤㻝 㻝㻜㻜 㻝㻜㻜 㻤㻡 㻣 Air suction grille
㻥㻢㻚㻡

Piping 㻤 Corner decoration cover


Piping 㻥 Drain hose
)&$*%9(%
(*1) Not applicable to recessed lighting. );)4%9(% 㻝㻜 Knockout hole.
(*2) Required space for entering with vacuum cleaner tube.
(*3) Make sure the decoration panel discharge outlet is not blocked. Air suction grille
Installation direction ϮϭϮϭϲϱϴ
• Split - Sky Air • FCAG-B 7
• Indoor Unit • FCAG-B

5 Dimensional drawings
5-1 Dimensional Drawings

&'Ͳ
Notes
 Location of nameplate
The unit nameplate is located on the control box cover.
The decoration panel nameplate is located on the piping-side panel frame, under the corner cover.
 When installing optional accessories, refer to their respective documentation.
 Make sure the distance between the ceiling and the cassette does not exceed ·35·mm.
The maximum ceiling opening is ·910·mm.
 When the conditions in the ceiling exceed 30°C ambient temperature and 80% relative humidity, or when fresh air is inducted into the ceiling, additional insulation is required (polyethylene foam, thickness •·10·mm).
 When installing a sensor kit, there will be a sensor on this location. For details, see the drawing of the sensor kit.
 When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller.

5 ·300· or less
㻠㻞㻜
See note
㻌㻌㻌㻌㻌㻌㻌㻌㻌㻌㻌 ·5·. 㻢

Drain 㻌side

㻰㻱㼀㻭㻵㻸㻌㻌㻭 㻰㻱㼀㻭㻵㻸㻌㻭
·2· places ·2· places

See note ·3·.


Opposite side

Suspension position
Opposite side 㻢㻣 㻥㻢㻚㻡
㻥 㻡㻟
㻭 㻡㻠㻚㻡㻡㻠㻚㻡 㻥㻢㻚㻡

㻤㻢㻜㻙㻥㻝㻜

㻤㻜

㻤㻜
㻥㻡㻜
㻣㻤㻜

㻞㻡㻚㻠

㻝㻜㻜
㻝㻜㻜

㻞㻡㻚㻠
㻞㻝㻟
Ceiling opening

㻝㻞㻝㻚㻡

㻝㻞㻝㻚㻡
㻟㻡㻜

㻟㻡㻜
㻝㻜㻜

㻝㻜㻜
 㻣㻡

㻤㻜
㻝㻜

㻤㻜
㻥㻡
㻠㻞㻜 㻭㻮
Piping side )&$*%9(%
㻣㻝㻜 See note ·6·. 㻥㻡㻜 )&$*%9(% );)4%9(%
Suspension position )&$+*+9(%
㻤㻢㻜㻙㻥㻝㻜 );)4%9(%
㻤㻠㻜
Adjustable

Ceiling opening See note ·3·.


㻡㻡 㻤㻠㻜 㻡㻡 㻟㻠㻜
㻰㻱㼀㻭㻵㻸㻌㻌㻮 㻰㻱㼀㻭㻵㻸㻌㻮
㻠 㻝 㻞 ·2· places ·2· places
㻜㻙㻢㻣㻡

㻮 㻟
Opposite side Opposite side
㻝㻣㻞
Required installation space

㻟㻡㻜
㻟㻡㻜
㻯 㻝㻞㻝㻚㻡 㻝㻞㻝㻚㻡

㻭㻭
㻡㻞
㻞㻝㻣

㻝㻡㻞
㻝㻥㻞

㻥㻢㻚㻡 㻡㻠㻚㻡㻡㻠㻚㻡

㻥㻡

㻡㻟
㻢㻣
·2700· or more

㻟㻡 㻟㻡 㻞㻤㻜 㻤㻝 㻝㻜㻜 㻝㻜㻜 㻤㻡


㻠㻡

㻥㻢㻚㻡
㻡 㻤㻝 㻝㻜㻜 㻝㻜㻜 㻤㻡
㻠㻌㻙㻌㻹㻤㻌㻌㻌㻌㻌㻌㻌㻌㻹㻝㻜
OR 㻟㻟㻜
See note ·3·. See note ·3·. Suspension bolt
)&$*%9(% )&$*%9(%
㻭㻾㻾㻻㼃㻌㼂㻵㻱㼃㻌㻯 )&$+*+9(% );)4%9(%
);)4%9(%

Item Name
Respect the distances shown on the figure. ·1500· or more 㻝 Liquid pipe connection port
Ceiling-mounted lighting ·200· or more 㻞
Gas pipe connection port
Air fan Other unit
㻟 Drain pipe connection
·1500· or more ·1500· or more 㻠 Power supply wiring intake
·200· or more
㻡 Transmission wiring intake
·1500· or more 㻢 hole Air discharge outlet
·1500· or more
·2000· or more 㻣 Flat grille assembly
·4000· or more Required installation space 㻤 Corner decoration cover
If a discharge outlet is closed up with the "sealing member" option kit, then the required
㻥 Drain hose
installation space on that (closed up) side is ·500·mm instead of ·1500·mm. 㻝㻜 Knockout hole.

ϮϭϮϭϳϬϯ

8 • Split - Sky Air • FCAG-B


• Indoor Unit • FCAG-B

5 Dimensional drawings
5-2 Dimensional Drawings with Accessories

&'Ͳ 3
Installation methods
Remote control dimensions
Decoration panel Designer decoration panel
Transmitter
Receiver Receiver
ON/OFF
Drain side 5
Drain side
DOWN

UP

FAN
㻝㻡㻣

Decoration panel
Decoration Piping side
panel
Piping side
㻢㻞 㻝㻣㻚㻡

Self-cleaning decoration panel


Receiver
Remote control holder Drain side
Installation methods
Installation to wall surface

Wireless remote control Decoration


panel
Piping side
Remote control holder
Front panel Model name Option
Receiver detail Decoration panel
BYCQ140E2W1(W) BRC7FA532F
BYCQ140E2W1B BRC7FA532FB
Self-cleaning decoration BYCQ140E2GFW1 BRC7FA532F
panel BYCQ140E2GFW1B BRC7FA532FB
Designer decoration BYCQ140E2P BRC7FB532F
panel BYCQ140E2PB BRC7FB532FB

ϯϭϮϭϳϱϬ
&'Ͳ
Installation methods

Decoration panel Designer decoration panel


Sensor kit Sensor kit
Drain side
Drain side

Decoration panel Decoration panel


Piping side
Piping side

Self-cleaning decoration panel


Sensor kit Drain side

Decoration panel
Piping side

Front panel Model name Option


BYCQ140E2W1(W) BRYQ140B8
Decoration panel
BYCQ140E2W1B BRYQ140B8B
Self-cleaning decoration BYCQ140E2GFW1 BRYQ140B8
panel BYCQ140E2GFW1B BRYQ140B8B

Designer decoration BYCQ140E2P BRYQ140C8


panel BYCQ140E2PB BRYQ140C8B

ϯϭϮϭϳϱϱ
• Split - Sky Air • FCAG-B 9
• Indoor Unit • FCAG-B

5 Dimensional drawings
5-3 Dimensional Drawings with Fresh Air Intake

&'Ͳ AA AB Model name


FCAG35/50/60/71BVEB
264 306
FXFQ20/25/32/40/50/63BVEB
㻡㻡 㻤㻠㻜 㻡㻡 Duct FCAG100/125/140BVEB
306 348
Left side FXFQ80/100BVEB
Piping side FCAHG71/100/125/140HVEB
348 390
FXFQ125BVEB
See note ·3·.
5

㻠㻞㻣
㻟㻞㻤

Static pressure in chamber [Pa]





㻤㻠㻜




㻟㻞㻤


㻠㻞㻣


See note ·3·. 
Drain side 


㻠㻠㻤 Duct View ·A· 
Service access panel 㻔㻝㻜㻜㻜㻕 
㻡㻜㻤 Right side ·450 x 450 mm· or more
㻝㻠㻤

      
See note ·1·. Air flow rate [m³/min]
㻭㻭

㻞㻣㻡
㻝㻢㻡

Suction chamber 㻠㻡㻡 T-joint


Ceiling opening Field supply
Decoration panel 㻣㻞㻡

㻝㻠㻤
A Inlet
㻭㻮

㻟㻝㻣
㻞㻜㻣
Notes
1. When installing a fresh air intake kit, provide a service access panel. Suction chamber
2. Field construction 㻠㻡㻡
Designer decoration panel
3. This corner discharge outlet needs to be closed. Ceiling opening
4. When installing a duct fan, use a wiring adapter to link the duct fan to the fan of the indoor unit.
5. The intake air flow rate is recommended to be ”20% of the air flow rate at high fan speed.
If the intake air flow rate is too large, the operating sound may increase, and the detection of the indoor unit suction temperature may be affected.
6. This indicates the distance between the T-joint inlet and the indoor unit inlet when the T-tube is connected.
ϯϭϮϭϳϰϭ

10 • Split - Sky Air • FCAG-B


• Indoor Unit • FCAG-B

6 Centre of gravity
6-1 Centre of Gravity

&'Ͳ 3
㻤㻠㻜

6
㻤㻠㻜


Model A B C D
)&$*㹼%9(% 204 70 400 405
)&$*㹼%9(% 246 100 400 405
)&$+*㹼+9(% 288 135 400 405
);)4㹼%9(% 204 70 395 400
);)4㹼%9(% 246 100 395 400
);)4%9(% 288 135 395 400

ϰϭϮϭϲϱϵ
• Split - Sky Air • FCAG-B 11
• Indoor Unit • FCAG-B

7 Piping diagrams
7-1 Piping Diagrams

&'Ͳ Model A B
FCAG35BVEB 6.35 9.52
FCAG50BVEB 12.7
7 FCAG60BVEB
FCAG71BVEB 9.52 15.9
FCAG100BVEB
FCAG125BVEB
FCAG140BVEB
FCAHG71BVEB
Refrigerant flow FCAHG100BVEB
FCAHG125BVEB
Cooling FCAHG140BVEB
Heating

Heat exchanger

M Fan

㻌㻭

Liquid pipe connection


port

㻌㻮
Gas pipe connection
port
ϰϭϮϭϰϯϯ
12 • Split - Sky Air • FCAG-B
• Indoor Unit • FCAG-B

8 Wiring diagrams
8-1 Wiring Diagrams - Single Phase

&'Ͳ 3
WIRING DIAGRAM
Z2C R2T R3T S1L
N=1 RECEIVER / DISPLAY UNIT (OPTIONAL)
t° t° A5P X1A X1A H1P X1M

GRN
H2P BS1 T2

BLK
BLK
BLK
BLK

BLK
BLK
SS1 H3P INPUT FROM OUTSIDE
X2A T1
K2R H4P
1 X2M X27A NE V1R F2 CENTRAL REMOTE
X88A X15A H5P
2 + SS2
H6P F1 CONTROLLER (NOTE 4
1 BLK
3 F1U (NOTE 10) Z1F P2 P2
- DS1 A6P
OUTDOOR 2 WHT X24A R1T

8
(NOTE 3) EMG 1 NORM(NOTE 8) P1 P1

H05VV-U4G2.5 3 RED TC RC C105 2 BLK
BLK
(NOTE 7) + ON OFF BLK WIRED REMOTE
BLK
BLK CONTROLLER
X33A(NOTE 8) BLK
PS HAP (NOTE 6)
CONTROL BOX LAYOUT PE X50A X36A
X70A R1 X39A X30A MSW M4S
X36A R1T A2P (YELLOW) X35A
X16A (NOTE 8)
(WHITE) (WHITE) (WHITE) X1 + - A1P
X33A COMPRESSOR KCR
X30A (WHITE) X81A X39A X2A V2R X35A X70A
(WHITE) (WHITE) (BLACK) OPERATION X2
X16A (NOTE 8)(NOTE 8) X25A X81A(NOTE 8) MSW M3S
FAN X3 X901A
KFR
OPERATION

WHT

WHT
RED
BLU
X4

BLK
BLK
BLK
BLK
BLK
Z1C
TERMINAL FOR F1U N=4 MSW M2S
X1M

WHT
RED

BLK
OPERATION DISPLAY
A1P X1A F2U KHuR WHT
R1T
M1P MS
A3P A4P
YC t° MSW M1S
X2M Y2 M1F MS CN1 S1RH
X24A X88A X25A X15A A7P 3~ SENSOR KIT (OPTIONAL)
X23A X50A (BLUE) (WHITE) X901A %H2O
(BLACK) (BLUE) ADAPTOR FOR WIRING (OPTIONAL NOTE 9)
(BLUE) (WHITE) (WHITE) A2P INDOOR

NOTES: INDOOR UNIT H2P PILOT LAMP (TIMER: GREEN)


1. : TERMINAL BLOCK, : CONNECTOR, : FIELD WIRING A1P MAIN PCB H3P PILOT LAMP
2. IN CASE OF SIMULTANEOUS OPERATION INDOOR UNIT SYSTEM, SEE THE INDOOR UNIT WIRING ONLY. C105 CAPACITOR (FILTER SIGN: RED)
3. FOR DETAILS, SEE WIRING DIAGRAM ATTACHED TO THE OUTDOOR UNIT. DS1 DIP SWITCH ON PCB H4P PILOT LAMP
F1U FUSE (T, 3.15A 250V) (DEFROST: ORANGE)
4. IN CASE OF USING CENTRAL REMOTE CONTROLLER, CONNECT IT TO THE UNIT IN ACCORDANCE WITH HAP FLASHING LAMP H5P PILOT LAMP
THE ATTACHED INSTALLATION MANUAL. (SERVICE MONITOR: GREEN) (ELEMENT CLEANING: RED)
5. IN CASE OF SIMULTANEOUS OPERATION SYSTEM, CONNECTED QUANTITY OF THE INDOOR UNITS K2R MAGNETIC RELAY H6P PILOT LAMP (TIMER: GREEN)
VARIES ACCORDING TO THE CONNECTED OUTDOOR UNIT. M1P MOTOR (DRAIN PUMP) SS1 DIP SWITCH (MAIN / SUB)
M1F MOTOR (INDOOR FAN) SS2 DIP SWITCH
6. IN CASE OF MAIN/SUB CHANGEOVER, SEE INSTALLATION MANUAL ATTACHED TO THE REMOTE CONTROLLER. M1S-M4S MOTOR (SWING BLADE) (WIRELESS ADDRESS SET)
7. SHOWN ONLY IN CASE OF PROTECTION PIPING, USE H07RN-F IN CASE OF NO PROTECTION. R1 RESISTOR ADAPTOR FOR WIRING
8. X24A, X33A, X35A, X39A, X70A, X81A ARE CONNECTED WHEN OPTIONAL ACCESSORIES ARE BEING R1T THERMISTOR (AIR) A7P ADAPTER PCB
USED, SEE WIRING DIAGRAM OF THIS ACCESSORY. R2T, R3T THERMISTOR (COIL) F1U FUSE (5A, 250V)
9. CONNECT POWER OF ADAPTER FOR WIRING TO TERMINAL BLOCK (X2M) OF INDOOR UNIT DIRECTLY. S1L FLOAT SWITCH (DRAIN PUMP) F2U FUSE (5A, 250V)
V1R DIODE BRIDGE KHuR MAGNETIC RELAY
10. FUSE F1U ON MAIN PCB (A1P) IS PRESENT ONLY IN FOLLOWING UNITS: FCAG 35, 50, 60, 71. V2R IGBT POWER MODULE KCR MAGNETIC RELAY
X15-901A CONNECTOR KFR MAGNETIC RELAY
X1M TERMINAL BLOCK X1-2A CONNECTOR
(REMOTE CONTROLLER) CONNECTORS FOR OPTIONAL PARTS
X2M TERMINAL BLOCK X24A CONNECTOR
IN CASE OF SIMULTANEOUS OPERATION SYSTEM WIRE COLORS (POWER SUPPLY) (WIRELESS REMOTE CONTROLLER)
凚NOTE 5凛 BLK: BLACK RED: RED Z1C, Z2C FERRITE CORE X33A CONNECTOR
BLU: BLUE WHT: WHITE Z1F NOISE FILTER (ADAPTOR FOR WIRING)
PS POWER SUPPLY CIRCUIT X35A CONNECTOR
1 1 1 YLW: YELLOW GRN: GREEN
RC SIGNAL RECEIVER CIRCUIT X39A
BRN: BROWN PNK: PINK (AUTO CLEAN PANEL)
2 2 2 TC
NE
SIGNAL TRANSMISSION CIRCUIT
NOISELESS EARTH
X70A
X50A CONNECTOR (WI-FI ADAPTOR)
3 3 3 SENSOR KIT X81A CONNECTOR (SENSOR KIT)
A3P, A4P SENSOR KIT PCB WIRED REMOTE CONTROLLER
WIRELESS REMOTE CONTROLLER R1T THERMISTOR (AIR)
X2M X2M (RECEIVER / DISPLAY UNIT) HUMIDITY SENSOR
X2M A5P RECEIVER PCB A2P SENSOR PCB
REMOTE A6P DISPLAY PCB S1RH HUMIDITY SENSOR
CONTROLLER BS1 PUSH BUTTON (ON/OFF) CN1 CONNECTOR
X1-2A CONNECTOR
H1P PILOT LAMP (ON: RED)

ϯϭϭϲϴϭϮ

• Split - Sky Air • FCAG-B 13


• Indoor Unit • FCAG-B

9 Sound data
9-1 Sound Pressure Spectrum

&'ϯϱ
ŽŽůŝŶŐŵŽĚĞ ,ĞĂƚŝŶŐŵŽĚĞ
90 90 90 90
85 NR90 85 NR90

80 NR85 80 80 NR85 80
75 NR80 75 NR80

^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

70 NR75 70 70 NR75 70
65 NR70 65 NR70

9 60
55
NR65
NR60
60 60
55
NR65
NR60
60

50 NR55 50 50 NR55 50
45 NR50 45 NR50
40 NR45 40 40 NR45 40
35 NR40 35 NR40
30 NR35 30 30 NR35 30
25 NR30 25 NR30
20 NR25
20 20 20
NR0 NR25
15 NR0
NR5 NR10 NR15
NR20 15
NR5 NR10 NR15 NR20
10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA

KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁ KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁
>ĞŐĞŶĚ
ĚсͲǁĞŝŐŚƚĞĚƐŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů;ƐĐĂůĞĂĐĐŽƌĚŝŶŐƚŽ/Ϳ͘
 ^ĐĂůĞ &ĂŶƐƉĞĞĚ
,ŝŐŚ ŽŽůŝŶŐ dŽƚĂůĚ ,ĞĂƚŝŶŐ dŽƚĂůĚ

 DĞĚŝƵŵ
       
 >Žǁ
Ě ϯϭ͕Ϭ Ϯϵ͕Ϭ Ϯϳ͕Ϭ Ě ϯϭ͕Ϭ Ϯϵ͕Ϭ Ϯϳ͕Ϭ
>ŽĐĂƚŝŽŶŽĨŵŝĐƌŽƉŚŽŶĞ
EŽƚĞƐ
ϭ KƉĞƌĂƚŝŶŐĐŽŶĚŝƚŝŽŶƐ͗ƉŽǁĞƌƐŽƵƌĐĞϮϮϬͲϮϰϬsͬϮϮϬsϱϬͬϲϬ,nj͖:/^ƐƚĂŶĚĂƌĚ

Ϯ ĂĐŬŐƌŽƵŶĚŶŽŝƐĞĂůƌĞĂĚLJƚĂŬĞŶŝŶƚŽĂĐĐŽƵŶƚ͘

ϯ KƉĞƌĂƚŝŶŐŶŽŝƐĞǀĂƌŝĞƐĚĞƉĞŶĚŝŶŐŽŶŽƉĞƌĂƚŝŽŶĂŶĚĂŵďŝĞŶƚĐŽŶĚŝƚŝŽŶƐ͘

ϰ dŚĞŽƉĞƌĂƚŝŽŶŶŽŝƐĞŵĞĂƐƵƌŝŶŐŵĞƚŚŽĚŝƐŝŶĂĐĐŽƌĚĂŶĐĞǁŝƚŚ:/^ϵϲϭϮ͘

ϱ DĞĂƐƵƌŝŶŐůŽĐĂƚŝŽŶ͗ĂŶĞĐŚŽŝĐĐŚĂŵďĞƌ
ϯϭϮϭϲϲϬ
&'ϱϬ ŽŽůŝŶŐŵŽĚĞ ,ĞĂƚŝŶŐŵŽĚĞ
90 90 90 90
85 NR90 85 NR90

80 NR85 80 80 NR85 80
75 NR80 75 NR80
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

70 70 70 70
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

NR75 NR75
65 NR70 65 NR70
60 NR65 60 60 NR65 60
55 NR60 55 NR60
50 NR55 50 50 NR55 50
45 NR50 45 NR50
40 NR45 40 40 NR45 40
35 NR40 35 NR40
30 NR35 30 30 NR35 30
25 NR30 25 NR30
20 NR25
20 20 20
NR0 NR25
15 NR0
NR5 NR10 NR15
NR20 15
NR5 NR10 NR15 NR20
10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁ KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁
>ĞŐĞŶĚ
ĚсͲǁĞŝŐŚƚĞĚƐŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů;ƐĐĂůĞĂĐĐŽƌĚŝŶŐƚŽ/Ϳ͘
 ^ĐĂůĞ &ĂŶƐƉĞĞĚ

 ,ŝŐŚ ŽŽůŝŶŐ dŽƚĂůĚ ,ĞĂƚŝŶŐ dŽƚĂůĚ


 DĞĚŝƵŵ
       
 >Žǁ
Ě ϯϭ͕Ϭ Ϯϵ͕Ϭ Ϯϳ͕Ϭ Ě ϯϭ͕Ϭ Ϯϵ͕Ϭ Ϯϳ͕Ϭ
>ŽĐĂƚŝŽŶŽĨŵŝĐƌŽƉŚŽŶĞ
EŽƚĞƐ
ϭ KƉĞƌĂƚŝŶŐĐŽŶĚŝƚŝŽŶƐ͗ƉŽǁĞƌƐŽƵƌĐĞϮϮϬͲϮϰϬsͬϮϮϬsϱϬͬϲϬ,nj͖:/^ƐƚĂŶĚĂƌĚ

Ϯ ĂĐŬŐƌŽƵŶĚŶŽŝƐĞĂůƌĞĂĚLJƚĂŬĞŶŝŶƚŽĂĐĐŽƵŶƚ͘

ϯ KƉĞƌĂƚŝŶŐŶŽŝƐĞǀĂƌŝĞƐĚĞƉĞŶĚŝŶŐŽŶŽƉĞƌĂƚŝŽŶĂŶĚĂŵďŝĞŶƚĐŽŶĚŝƚŝŽŶƐ͘

ϰ dŚĞŽƉĞƌĂƚŝŽŶŶŽŝƐĞŵĞĂƐƵƌŝŶŐŵĞƚŚŽĚŝƐŝŶĂĐĐŽƌĚĂŶĐĞǁŝƚŚ:/^ϵϲϭϮ͘

ϱ DĞĂƐƵƌŝŶŐůŽĐĂƚŝŽŶ͗ĂŶĞĐŚŽŝĐĐŚĂŵďĞƌ
ϯϭϮϭϲϲϭ

14 • Split - Sky Air • FCAG-B


• Indoor Unit • FCAG-B

9 Sound data
9-1 Sound Pressure Spectrum

&'ϲϬ ŽŽůŝŶŐŵŽĚĞ ,ĞĂƚŝŶŐŵŽĚĞ 3


90 90 90 90
85 NR90 85 NR90

80 NR85 80 80 NR85 80
75 NR80 75 NR80
70 NR75 70 70 NR75 70

^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

65 NR70 65 NR70
60
55
NR65
NR60
60 60
55
NR65
NR60
60
9
50 NR55 50 50 NR55 50
45 NR50 45 NR50
40 NR45 40 40 NR45 40
35 NR40 35 NR40
30 NR35 30 30 NR35 30
25 NR30 25 NR30
20 NR25
20 20 20
NR0 NR25
15 NR0
NR5 NR10 NR15
NR20 15
NR5 NR10 NR15 NR20
10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁ KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁
>ĞŐĞŶĚ
ĚсͲǁĞŝŐŚƚĞĚƐŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů;ƐĐĂůĞĂĐĐŽƌĚŝŶŐƚŽ/Ϳ͘
 ^ĐĂůĞ &ĂŶƐƉĞĞĚ

 ,ŝŐŚ ŽŽůŝŶŐ dŽƚĂůĚ ,ĞĂƚŝŶŐ dŽƚĂůĚ


 DĞĚŝƵŵ
       
 >Žǁ
Ě ϯϯ͕Ϭ ϯϭ͕Ϭ Ϯϴ͕Ϭ Ě ϯϯ͕Ϭ ϯϭ͕Ϭ Ϯϴ͕Ϭ
>ŽĐĂƚŝŽŶŽĨŵŝĐƌŽƉŚŽŶĞ
EŽƚĞƐ
ϭ KƉĞƌĂƚŝŶŐĐŽŶĚŝƚŝŽŶƐ͗ƉŽǁĞƌƐŽƵƌĐĞϮϮϬͲϮϰϬsͬϮϮϬsϱϬͬϲϬ,nj͖:/^ƐƚĂŶĚĂƌĚ

Ϯ ĂĐŬŐƌŽƵŶĚŶŽŝƐĞĂůƌĞĂĚLJƚĂŬĞŶŝŶƚŽĂĐĐŽƵŶƚ͘

ϯ KƉĞƌĂƚŝŶŐŶŽŝƐĞǀĂƌŝĞƐĚĞƉĞŶĚŝŶŐŽŶŽƉĞƌĂƚŝŽŶĂŶĚĂŵďŝĞŶƚĐŽŶĚŝƚŝŽŶƐ͘

ϰ dŚĞŽƉĞƌĂƚŝŽŶŶŽŝƐĞŵĞĂƐƵƌŝŶŐŵĞƚŚŽĚŝƐŝŶĂĐĐŽƌĚĂŶĐĞǁŝƚŚ:/^ϵϲϭϮ͘

ϱ DĞĂƐƵƌŝŶŐůŽĐĂƚŝŽŶ͗ĂŶĞĐŚŽŝĐĐŚĂŵďĞƌ
ϯϭϮϭϲϲϮ
&'ϳϭ ŽŽůŝŶŐŵŽĚĞ ,ĞĂƚŝŶŐŵŽĚĞ
90 90 90 90
85 NR90 85 NR90

80 NR85 80 80 NR85 80
75 NR80 75 NR80
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

70 70 70 70
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

NR75 NR75
65 NR70 65 NR70
60 NR65 60 60 NR65 60
55 NR60 55 NR60
50 NR55 50 50 NR55 50
45 NR50 45 NR50
40 NR45 40 40 NR45 40
35 NR40 35 NR40
30 NR35 30 30 NR35 30
25 NR30 25 NR30
20 NR25
20 20 20
NR0 NR25
15 NR0
NR5 NR10 NR15
NR20 15
NR5 NR10 NR15 NR20
10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁ KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁
>ĞŐĞŶĚ
ĚсͲǁĞŝŐŚƚĞĚƐŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů;ƐĐĂůĞĂĐĐŽƌĚŝŶŐƚŽ/Ϳ͘
 ^ĐĂůĞ &ĂŶƐƉĞĞĚ

 ,ŝŐŚ ŽŽůŝŶŐ dŽƚĂůĚ ,ĞĂƚŝŶŐ dŽƚĂůĚ


 DĞĚŝƵŵ
       
 >Žǁ
Ě ϯϱ͕Ϭ ϯϭ͕Ϭ Ϯϴ͕Ϭ Ě ϯϯ͕Ϭ ϯϭ͕Ϭ Ϯϴ͕Ϭ
>ŽĐĂƚŝŽŶŽĨŵŝĐƌŽƉŚŽŶĞ
EŽƚĞƐ
ϭ KƉĞƌĂƚŝŶŐĐŽŶĚŝƚŝŽŶƐ͗ƉŽǁĞƌƐŽƵƌĐĞϮϮϬͲϮϰϬsͬϮϮϬsϱϬͬϲϬ,nj͖:/^ƐƚĂŶĚĂƌĚ

Ϯ ĂĐŬŐƌŽƵŶĚŶŽŝƐĞĂůƌĞĂĚLJƚĂŬĞŶŝŶƚŽĂĐĐŽƵŶƚ͘

ϯ KƉĞƌĂƚŝŶŐŶŽŝƐĞǀĂƌŝĞƐĚĞƉĞŶĚŝŶŐŽŶŽƉĞƌĂƚŝŽŶĂŶĚĂŵďŝĞŶƚĐŽŶĚŝƚŝŽŶƐ͘

ϰ dŚĞŽƉĞƌĂƚŝŽŶŶŽŝƐĞŵĞĂƐƵƌŝŶŐŵĞƚŚŽĚŝƐŝŶĂĐĐŽƌĚĂŶĐĞǁŝƚŚ:/^ϵϲϭϮ͘

ϱ DĞĂƐƵƌŝŶŐůŽĐĂƚŝŽŶ͗ĂŶĞĐŚŽŝĐĐŚĂŵďĞƌ ϯϭϮϭϲϲϯ

• Split - Sky Air • FCAG-B 15


• Indoor Unit • FCAG-B

9 Sound data
9-1 Sound Pressure Spectrum

&'ϭϬϬ ŽŽůŝŶŐŵŽĚĞ ,ĞĂƚŝŶŐŵŽĚĞ


90 90 90 90
85 NR90 85 NR90

80 NR85 80 80 NR85 80
75 75

^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁
NR80 NR80
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

70 NR75 70 70 NR75 70
65 NR70 65 NR70

9 60
55
NR65 60 60 NR65 60
NR60 55 NR60
50 NR55 50 50 NR55 50
45 NR50 45 NR50
40 NR45 40 40 NR45 40
35 NR40 35 NR40
30 NR35 30 30 NR35 30
25 NR30 25 NR30
20 NR25
20 20 20
NR0 NR25
15 NR0
NR5 NR10 NR15
NR20 15
NR5 NR10 NR15 NR20
10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁ KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁
>ĞŐĞŶĚ
ĚсͲǁĞŝŐŚƚĞĚƐŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů;ƐĐĂůĞĂĐĐŽƌĚŝŶŐƚŽ/Ϳ͘
 ^ĐĂůĞ &ĂŶƐƉĞĞĚ

,ŝŐŚ ŽŽůŝŶŐ dŽƚĂůĚ ,ĞĂƚŝŶŐ dŽƚĂůĚ



 DĞĚŝƵŵ        
 >Žǁ
Ě ϯϳ͕Ϭ ϯϯ͕Ϭ Ϯϵ͕Ϭ Ě ϯϳ͕Ϭ ϯϯ͕Ϭ Ϯϵ͕Ϭ
>ŽĐĂƚŝŽŶŽĨŵŝĐƌŽƉŚŽŶĞ
EŽƚĞƐ
ϭ KƉĞƌĂƚŝŶŐĐŽŶĚŝƚŝŽŶƐ͗ƉŽǁĞƌƐŽƵƌĐĞϮϮϬͲϮϰϬsͬϮϮϬsϱϬͬϲϬ,nj͖:/^ƐƚĂŶĚĂƌĚ

Ϯ ĂĐŬŐƌŽƵŶĚŶŽŝƐĞĂůƌĞĂĚLJƚĂŬĞŶŝŶƚŽĂĐĐŽƵŶƚ͘

ϯ KƉĞƌĂƚŝŶŐŶŽŝƐĞǀĂƌŝĞƐĚĞƉĞŶĚŝŶŐŽŶŽƉĞƌĂƚŝŽŶĂŶĚĂŵďŝĞŶƚĐŽŶĚŝƚŝŽŶƐ͘

ϰ dŚĞŽƉĞƌĂƚŝŽŶŶŽŝƐĞŵĞĂƐƵƌŝŶŐŵĞƚŚŽĚŝƐŝŶĂĐĐŽƌĚĂŶĐĞǁŝƚŚ:/^ϵϲϭϮ͘

ϱ DĞĂƐƵƌŝŶŐůŽĐĂƚŝŽŶ͗ĂŶĞĐŚŽŝĐĐŚĂŵďĞƌ ϯϭϮϭϲϲϰ
&'ϭϮϱ ŽŽůŝŶŐŵŽĚĞ ,ĞĂƚŝŶŐŵŽĚĞ
90 90 90 90
85 NR90 85 NR90

80 NR85 80 80 NR85 80
75 NR80 75 NR80
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

70 70 70 70
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

NR75 NR75
65 NR70 65 NR70
60 NR65 60 60 NR65 60
55 NR60 55 NR60
50 NR55 50 50 NR55 50
45 NR50 45 NR50
40 NR45 40 40 NR45 40
35 NR40 35 NR40
30 NR35 30 30 NR35 30
25 NR30 25 NR30
20 NR25
20 20 20
NR0 NR25
15 NR0
NR5 NR10 NR15
NR20 15
NR5 NR10 NR15 NR20
10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁ KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁
>ĞŐĞŶĚ
ĚсͲǁĞŝŐŚƚĞĚƐŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů;ƐĐĂůĞĂĐĐŽƌĚŝŶŐƚŽ/Ϳ͘
 ^ĐĂůĞ &ĂŶƐƉĞĞĚ

 ,ŝŐŚ ŽŽůŝŶŐ dŽƚĂůĚ ,ĞĂƚŝŶŐ dŽƚĂůĚ


 DĞĚŝƵŵ        
 >Žǁ
Ě ϰϭ͕Ϭ ϯϱ͕Ϭ Ϯϵ͕Ϭ Ě ϰϭ͕Ϭ ϯϱ͕Ϭ Ϯϵ͕Ϭ
>ŽĐĂƚŝŽŶŽĨŵŝĐƌŽƉŚŽŶĞ
EŽƚĞƐ
ϭ KƉĞƌĂƚŝŶŐĐŽŶĚŝƚŝŽŶƐ͗ƉŽǁĞƌƐŽƵƌĐĞϮϮϬͲϮϰϬsͬϮϮϬsϱϬͬϲϬ,nj͖:/^ƐƚĂŶĚĂƌĚ

Ϯ ĂĐŬŐƌŽƵŶĚŶŽŝƐĞĂůƌĞĂĚLJƚĂŬĞŶŝŶƚŽĂĐĐŽƵŶƚ͘

ϯ KƉĞƌĂƚŝŶŐŶŽŝƐĞǀĂƌŝĞƐĚĞƉĞŶĚŝŶŐŽŶŽƉĞƌĂƚŝŽŶĂŶĚĂŵďŝĞŶƚĐŽŶĚŝƚŝŽŶƐ͘

ϰ dŚĞŽƉĞƌĂƚŝŽŶŶŽŝƐĞŵĞĂƐƵƌŝŶŐŵĞƚŚŽĚŝƐŝŶĂĐĐŽƌĚĂŶĐĞǁŝƚŚ:/^ϵϲϭϮ͘

ϱ DĞĂƐƵƌŝŶŐůŽĐĂƚŝŽŶ͗ĂŶĞĐŚŽŝĐĐŚĂŵďĞƌ ϯϭϮϭϲϲϱ

16 • Split - Sky Air • FCAG-B


• Indoor Unit • FCAG-B

9 Sound data
9-1 Sound Pressure Spectrum

&'ϭϰϬ ŽŽůŝŶŐŵŽĚĞ ,ĞĂƚŝŶŐŵŽĚĞ 3


90 90 90 90
85 NR90 85 NR90

80 NR85 80 80 NR85 80

^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁
^ŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů΀Ě΁

75 NR80 75 NR80
70 NR75 70 70 NR75 70
65 NR70 65 NR70
60
55
NR65
NR60
60 60
55
NR65
NR60
60
9
50 NR55 50 50 NR55 50
45 NR50 45 NR50
40 NR45 40 40 NR45 40
35 NR40 35 NR40
30 NR35 30 30 NR35 30
25 NR30 25 NR30
20 NR25
20 20 20
NR0 NR25
15 NR0
NR5 NR10 NR15
NR20 15
NR5 NR10 NR15 NR20
10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁ KĐƚĂǀĞďĂŶĚĐĞŶƚƌĞĨƌĞƋƵĞŶĐLJ΀,nj΁
>ĞŐĞŶĚ
ĚсͲǁĞŝŐŚƚĞĚƐŽƵŶĚƉƌĞƐƐƵƌĞůĞǀĞů;ƐĐĂůĞĂĐĐŽƌĚŝŶŐƚŽ/Ϳ͘
 ^ĐĂůĞ &ĂŶƐƉĞĞĚ
,ŝŐŚ ŽŽůŝŶŐ dŽƚĂůĚ ,ĞĂƚŝŶŐ dŽƚĂůĚ

 DĞĚŝƵŵ        
 >Žǁ
Ě ϰϭ͕Ϭ ϯϱ͕Ϭ Ϯϵ͕Ϭ Ě ϰϭ͕Ϭ ϯϱ͕Ϭ Ϯϵ͕Ϭ
>ŽĐĂƚŝŽŶŽĨŵŝĐƌŽƉŚŽŶĞ
EŽƚĞƐ
ϭ KƉĞƌĂƚŝŶŐĐŽŶĚŝƚŝŽŶƐ͗ƉŽǁĞƌƐŽƵƌĐĞϮϮϬͲϮϰϬsͬϮϮϬsϱϬͬϲϬ,nj͖:/^ƐƚĂŶĚĂƌĚ

Ϯ ĂĐŬŐƌŽƵŶĚŶŽŝƐĞĂůƌĞĂĚLJƚĂŬĞŶŝŶƚŽĂĐĐŽƵŶƚ͘

ϯ KƉĞƌĂƚŝŶŐŶŽŝƐĞǀĂƌŝĞƐĚĞƉĞŶĚŝŶŐŽŶŽƉĞƌĂƚŝŽŶĂŶĚĂŵďŝĞŶƚĐŽŶĚŝƚŝŽŶƐ͘

ϰ dŚĞŽƉĞƌĂƚŝŽŶŶŽŝƐĞŵĞĂƐƵƌŝŶŐŵĞƚŚŽĚŝƐŝŶĂĐĐŽƌĚĂŶĐĞǁŝƚŚ:/^ϵϲϭϮ͘

ϱ DĞĂƐƵƌŝŶŐůŽĐĂƚŝŽŶ͗ĂŶĞĐŚŽŝĐĐŚĂŵďĞƌ
ϯϭϮϭϲϲϲ

• Split - Sky Air • FCAG-B 17


• Indoor Unit • FCAG-B

10 Air flow patterns


10 - 1 Air Flow Pattern - Cooling / Heating

&'ϯϱ

Air velocity distribution (cooling) Air velocity distribution (heating)


Air flow direction: horizontal Air flow direction: vertical
10 Air discharge: all-round Air discharge: all-round
2.7 m 2.7 m
1.5-1.7 m/s
1.3-1.5 m/s 1.5-1.7 m/s
1.1-1.3 m/s 2m 2m
1.3-1.5 m/s
0.9-1.1 m/s
1.1-1.3 m/s
0.7-0.9 m/s 0.9-1.1 m/s
0.5-0.7 m/s 1m 0.7-0.9 m/s 1m
0.5-0.7 m/s
0.3-0.5 m/s
0.3-0.5 m/s
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Air temperature distribution (cooling) Air temperature distribution (heating)


Air flow direction: horizontal Air flow direction: vertical
Air discharge: all-round Air discharge: all-round
2.7 m 2.7 m
20-21 >C
21-22 >C 2m 27-26 >C 2m
22-23 >C 26-25 >C
23-24 >C 25-24 >C
24-25 >C 1m 24-23 >C 1m
23-22 >C
25-26 >C 22-21 >C

0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

ϯϭϮϭϲϭϴ
&'ϱϬ

Air velocity distribution (cooling) Air velocity distribution (heating)


Air flow direction: horizontal Air flow direction: vertical

Air discharge: all-round Air discharge: all-round


2.7 m 2.7 m
1.5-1.7 m/s
1.3-1.5 m/s 1.5-1.7 m/s
1.1-1.3 m/s
2m 2m
1.3-1.5 m/s
0.9-1.1 m/s 1.1-1.3 m/s
0.7-0.9 m/s 0.9-1.1 m/s
0.5-0.7 m/s 1m 0.7-0.9 m/s 1m
0.5-0.7 m/s
0.3-0.5 m/s
0.3-0.5 m/s
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Air temperature distribution (cooling) Air temperature distribution (heating)


Air flow direction: horizontal Air flow direction: vertical

Air discharge: all-round Air discharge: all-round


2.7 m 2.7 m
20-21 >C
21-22 >C 2m 27-26 >C 2m
22-23 >C 26-25 >C
23-24 >C 25-24 >C
24-25 >C 24-23 >C
1m 1m
23-22 >C
25-26 >C 22-21 >C

0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

ϯϭϮϭϲϭϵ

18 • Split - Sky Air • FCAG-B


• Indoor Unit • FCAG-B

10 Air flow patterns


10 - 1 Air Flow Pattern - Cooling / Heating

&'ϲϬ 3
Air velocity distribution (cooling) Air velocity distribution (heating)
Air flow direction: horizontal Air flow direction: vertical
Air discharge: all-round Air discharge: all-round
10
2.7 m 2.7 m
1.5-1.7 m/s
1.3-1.5 m/s 1.5-1.7 m/s
1.1-1.3 m/s 2m 2m
1.3-1.5 m/s
0.9-1.1 m/s
1.1-1.3 m/s
0.7-0.9 m/s 0.9-1.1 m/s
0.5-0.7 m/s 1m 0.7-0.9 m/s 1m
0.3-0.5 m/s 0.5-0.7 m/s
0.3-0.5 m/s
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Air temperature distribution (cooling) Air temperature distribution (heating)


Air flow direction: horizontal Air flow direction: vertical
Air discharge: all-round Air discharge: all-round
2.7 m 2.7 m
20-21 >C
21-22 >C 2m 27-26 >C 2m
22-23 >C
26-25 >C
23-24 >C
25-24 >C
24-25 >C 24-23 >C
1m 1m
25-26 >C 23-22 >C
22-21 >C

0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

ϯϭϮϭϲϮϬ
&'ϳϭ

Air velocity distribution (cooling) Air velocity distribution (heating)


Air flow direction: horizontal Air flow direction: vertical
Air discharge: all-round Air discharge: all-round
2.7 m 2.7 m
1.5-1.7 m/s
1.3-1.5 m/s 1.5-1.7 m/s
1.1-1.3 m/s
2m 2m
1.3-1.5 m/s
0.9-1.1 m/s
1.1-1.3 m/s
0.7-0.9 m/s 0.9-1.1 m/s
0.5-0.7 m/s 1m 0.7-0.9 m/s 1m
0.3-0.5 m/s 0.5-0.7 m/s
0.3-0.5 m/s
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Air temperature distribution (cooling) Air temperature distribution (heating)


Air flow direction: horizontal Air flow direction: vertical
Air discharge: all-round Air discharge: all-round
2.7 m 2.7 m
20-21 >C
21-22 >C 2m 27-26 >C 2m
22-23 >C
26-25 >C
23-24 >C
25-24 >C
24-25 >C
1m 24-23 >C 1m
25-26 >C 23-22 >C
22-21 >C

0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

ϯϭϮϭϲϮϭ

• Split - Sky Air • FCAG-B 19


• Indoor Unit • FCAG-B

10 Air flow patterns


10 - 1 Air Flow Pattern - Cooling / Heating

&'ϭϬϬ

Air velocity distribution (cooling) Air velocity distribution (heating)


Air flow direction: horizontal Air flow direction: vertical
Air discharge: all-round Air discharge: all-round
10
2.7 m 2.7 m
1.5-1.7 m/s
1.3-1.5 m/s
1.1-1.3 m/s
2m 1.5-1.7 m/s 2m
1.3-1.5 m/s
0.9-1.1 m/s
1.1-1.3 m/s
0.7-0.9 m/s 0.9-1.1 m/s
0.5-0.7 m/s 1m 0.7-0.9 m/s 1m
0.3-0.5 m/s 0.5-0.7 m/s
0.3-0.5 m/s
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m
Air temperature distribution (cooling) Air temperature distribution (heating)
Air flow direction: horizontal
Air flow direction: vertical
Air discharge: all-round Air discharge: all-round
2.7 m 2.7 m
20-21 >C
21-22 >C 2m 27-26 >C 2m
22-23 >C 26-25 >C
23-24 >C 25-24 >C
24-25 >C 24-23 >C
1m 23-22 >C
1m
25-26 >C
22-21 >C

0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

ϯϭϮϭϲϮϮ
&'ϭϮϱͲϭϰϬ

Air velocity distribution (cooling) Air velocity distribution (heating)


Air flow direction: horizontal Air flow direction: vertical

Air discharge: all-round Air discharge: all-round


2.7 m 2.7 m
1.5-1.7 m/s
1.3-1.5 m/s 2m 1.5-1.7 m/s 2m
1.1-1.3 m/s
1.3-1.5 m/s
0.9-1.1 m/s
0.7-0.9 m/s 1.1-1.3 m/s
1m 0.9-1.1 m/s 1m
0.5-0.7 m/s 0.7-0.9 m/s
0.3-0.5 m/s 0.5-0.7 m/s
0.3-0.5 m/s
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Air temperature distribution (cooling) Air temperature distribution (heating)


Air flow direction: horizontal Air flow direction: vertical

Air discharge: all-round Air discharge: all-round


2.7 m 2.7 m
20-21 >C
21-22 >C 2m 27-26 >C 2m
22-23 >C
23-24 >C 26-25 >C
24-25 >C 25-24 >C
25-26 >C
1m 24-23 >C 1m
23-22 >C
22-21 >C
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

ϯϭϮϭϲϮϯ
20 • Split - Sky Air • FCAG-B
Daikin Europe N.V. Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
Daikin Europe N.V. participates in the Eurovent Certified
Performance programme for Liquid Chilling Packages
and Hydronic Heat Pumps, Fan Coil Units and Variable
Refrigerant Flow systems. Check ongoing validity of cer-
tificate: www.eurovent-certification.com

EEDEN19 03/19
The present leaflet is drawn up by way of information only and does not constitute an offer binding
upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its
knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fit-
ness for particular purpose of its content and the products and services presented therein. Specifica-
tions are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for
any direct or indirect damage, in the broadest sense, arising from or related to the use and/or inter-
pretation of this leaflet. All content is copyrighted by Daikin Europe N.V.