STANDARD
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION l MEXQYHAPOAHA5I OPI-AHM3ALUUI JIO CTAHLIAPTM3ALViM=ORGANISATION INTERNATIONALE DE NORMALISATION
Printed in Switzerland
e
This International Standard specifies a titrimetric method Dilute the test Portion (6.1) in about 100 ml of the water
for the determination of the alkalinity or acidity of (4.1).
glycerines for industrial use.
Add 3 drops of the phenolphthalein Solution (4.4), homo-
genize and note the colour obtained.
2 REFERENCES
Depending on the particular case, titrate the alkalinity with
ISO 1614, Glycerines for industrial use - Samples and test the Standard volumetric hydrochloric acid Solution (4.3)
methods - General. until the indicator is decolorized, or titrate the acidity with
the Standard volumetric sodium hydroxide Solution (4.2)
ISO 2096, Glycerines for industrial use - Methods of” until the first persistent pink colour appears.
sampling.
Use an ordinary burette, or, if the volume of the
Standard volumetric Solution is less than 2 ml, the micro-
3 PRINCIPLE iTeh STANDARD PREVIEW burette (5.1).
Titration
Solution of hydrochloric
(standards.iteh.ai)
of a test Portion with a Standard volumetric
acid or sodium hydroxide in the
presence of phenolphthalein as indicator.
ISO 1615:19767 EXPRESSION OF RESULTS
https://standards.iteh.ai/catalog/standards/sist/35db9bf0-5f56-4671-93f6-
4 REAGENTS 2c83d778d3ab/iso-1615-1976
The alkalinity or acidity, expressed conventionally in
milliequivalents per 100 g, is given by the formula
During the analysis, use only reagents of recognized analyti-
cal reagent grade.
1 100 V
VXEX -= IO-
4.1 Water free from carbon dioxide (see ISO 1614). m m
4.4 Phenolphthalein, 10 g/l ethanolic Solution. m is the mass, in grams, of the test Portion (6.1).
Dissolve 1 g of phenolphthalein in 95 % (V/V) ethanol and NOTE - If the concentration of the Standard volumetric solution
make up to 100 ml with the same ethanol. Add, drop by used is not exactly as specified in the list of reagents, an appropriate
correction should be made.
drop, approximately 0,02 N sodium hydroxide Solution
until the first appearance of a pink colour.
5 APPARATUS
8 TEST REPORT
Ordinary laboratory apparatus and
The test report shall include the following particulars :
5.1 Microburette, graduated in 0,Ol ml. a) the reference of the method used;
1
ISOl615=1976(E)
ANNEX