You are on page 1of 15
iS pean ORE eae peo She NCAR Eee elg 2020 ZAKF line filter Why use compressed air filter AGE ME WS Vi we AAMSHAAS, READE KMN BOHROS AR RAANNATD TAME, HARMS HBAS ES, RGMAMM MAA ARARGE TED, KER ‘OUR A] Ae RAT AN ae SN SER, ARLE HOw TAMRMEAS m, HFT RMR ME. Energy consumption AT RR HI RBSTAREAMS, USSORATE RARE HEOTEORDS —LUBRAMRERRAT, EA SEAM ALAR A ABET ALA ABO, i A barf) NESS FT- 10M EG RIS. ‘The atmosphere contains water vapour hydrocarbons and solid particles(about 140 million solid particles per cubic metre of airfound in the atmosphere), These impurities are inhaled into the air compressor and then entered tothe compressed air network together with residual lubricant, Failure to treat these contaminants in a timely manner will lead to corrosion of pipelines,endangering production equipment, harming too! sensitivity and lifespan, which will eventually afect the products quality For compressed air system, flter resistance is often the key {actor of air pressure drop. Under normal operating conditions, the energy consumption ofa filter contributes 80 % of the {otal operating cost, and the air pressure drop of 1 baris usually equal to 7 %-10 % of air compressor's energy loss. es — Ree Cost ofinstalation Maintenance 0% 10% as arRe Naser semnre Investment Energy The principle RBS Ti LR AOS UA RAM, RRM AMAA AEMAA TER TA, DASARI M NER RET SHENMEREMTA. QAO RARE MME SEA, ARLE Ae A I A A K, COG MAAMD TMA REAM, REE ME 3, BRAN, BRAS RON TT CMM ML > o> > > > Pa WR SRM ROHR MEAL Pm Freeze dryer Absorbent type dryer S TBRRERER, KORMNABTRAWAR, RANERES, —RTRRESROUSSME RAM FRKARAWR, HRA RMRSIMMEE, ID RAAENMAMRRRSAL EAR SONE. MATS HRI IE HO A wh AT HD AL RDA BORE, SOK ARAMA RODE MEER ALAM HOO REM SRA RAE NORM, ERB -2REM, SEHR MMALSM RBS TT, SASLAURISR. (AD-OLVR(E ATT: Aoki SR HUD TAMPMRNFOBARS, 5 OPRAH AT HARE.) a Pom abe inner automatic drain H RGSWMRRGR. ATSRRRLEMIS0-8573EHS% RAEI AD, Eh eS oh A HT HD I SI (RRA) MOR, WRK AEOMSURETOONI, RAMA, RECUR AFLKANRER BAROMETER. Shae HS lectcical timed drain _Filtors installed with a differential pressure gauge (OPC) can exactly indicate the pressure differences of element for limely replacement. When the pressure difference reach to ‘a certain value, that will increase energy consumption and hence eneray expense will exceed the value of element. Reliable and durable automatic drain from Europe is used with manual drain built-in function to ensure higher stability ‘and long life span Without auto drain, customer will need to incur additional manpower to drain condensate water manually. Otherwise, fltered oll and water will be enter to the downstream pipe and cause compressed air polluted again. (AD-01 Operation Guide: vertical anti-clockwise for manual . vertical clockwise for automatic .) 2 Sh I SR HS external mechanical automatic drain ‘Compressed air test laboratory: The ATS laboratory is designed with reference to the ISO-8573 compressed air standard totest ‘and analyze compressed air flter related indicators, such as filter accuracy (dust removal and oil removal) and filter pressure difference, The separation effect of water separator can be tested and analyzed, and the dew point can be tested. This is the enterprise has the research and development abllty and uarantees the product quality the important method. BORG UNER RAR MS HERA RINRATSH ARMM. — 00 SP RAMA, KORA AE. 1 leak test equipment = fi abig energy loss, many micro leakge Is not easy to detect. filters aro 100% strictly leak tested to ensure customer benefit. © BMTSR mB eM RARER, MF wA HARADA HR, He AMA; BK RRM BET, Hee — aR HS HI atbenE sss MERRNAAE MERA EkHeRee. a SOAR ER MERE, SARE AO SARL HS RAAREOLS, BAER RMR S ER, BIA si EL Ty MAME ASEM: 4 RMEMO BIAS, wT BHFORT, SARIN HEPES SMSSM, A eee FRM, SMHS TAONRS Zim RM GBR BETA MBE URNA ROM MER FAD HK BACAR AE mA ae by See MSMR OBE Design of angle inlet and top clamp of filter Inlet and Lvxincal High efficiency elements features 4.Filter paper: deep-pleated filter element has 3 times of filtration area than rapped type and higher space to hold the dustitalso has lower pressure drop and longer life span. . Rhombic shaped stainless steel mesh has larger effective filtration ‘area and smaller pressure drop ‘compare to round-hole type uses polyester wadding for the external coalescing layer, ‘compared to traditional foams, ithas high resistance to high temperature and corrosion Traditional foams is easily damaged after a period of time, ragged forms ‘can be blowed into down stream pipeline and possibly camange the production equipment. ‘No pull rod design to save installation space and easy todisassemble Elbow design between air iniot and element.less pressure drop ‘compared to vertical type. The housing is double treated with antioxidation and painting to resist corrosion Hai Dae tT Design of rectangular Separator BS Water separator Sk EEGSIEEMT ARERR AH ME TABI MRD K, EMD i A AOE. ATS ok 9} AO HOT A AR, SK ARARRES. CKPRE TREO RRORECTEGE FEB MAB. CIT Wa. Installing water separator before compressed air filter anddrying equipment can remove 95 % of liquid water, makingdownstream purification more efficient. The unique two-stage cyclone separation design makes it more effective than traditional type of water separalor. ‘The air and water separator can be installed in various position such as after the ale compressor, after the rear cooler or after the air receiver tank ASR: ‘Technical parameters: Lip: 0.7-1.6MPa ‘Working pressure: 0.7-1.6MPa fi: 100°C Max Operating temperature: 100°C Max Specification/ Flange water separation filter scale UKA ES W) EE AAKP BULB RMR TR us @oRt ait IER (nm) Model Conn. size Flow rate Interface Size inch m/min etm A 8 c Foo4sw 42" 13 45 95 207174 Foossw 31a" 13 45 95 207174 Fot00W aia" 28 100 95 267238 Fo1s0W ° 54 180 125301261 Fote1w 112" 51 180 125301261 Fos7ow 1-1/2" 10.5 370 125385345 Fo515W 2 146 518 170 504455 Fo74sW a 2a 748 17068434 Frosow = 2-1/2" 30 1060 200 820752 Fro61w EB 30 1060 © 2002 820752 F1650W x 467 1650 «= 2009815. FL2100W = DN125 63 222 8351274005 FL2600W -DN1S0 84 2065877, 14841175 FL3500W N50 105 «3707877, 18841275 FLaaasw N20 126 3448 65017851410 FL5189W N20 147-5189 = 65018851510 FLse30W N20 168 5930 650-1985 1610 FL6672W N20 189 6672650 « 20851710 FL7350W DN250 210 6672785 22851798 FLes42w —DN250 2428543785 23451896, FLt0096w —_0N300 286 = 100868752535 (2048 FLit6sow N30 33011649 90026352148 23 325 325 380 380 380 380 480 480 530 530 Diagram A A t ° oo. 2 1 cB D. Filter separator PALER RAOUL PRS MRATEHAEER, RATALKI, REATAAOKA. RAPSAPTABAMPOMSMARA MEME, HE BL-ORMRL, PHBL —MARPA WR. FRTLRRE RRO MOEA B, PHATRMM, CPRSRURK EMME. tunique separation itor is a combination of cyclone separation and filtration, with the advantages of saving installation space and reduce filter load. Cyclonic separation component can remove most ofthe liquid oil and water as well as large soli¢ particle as for filter element, itwill further remove dust. Separator filter element has two grades to choose from, mainly P(3.00 micron) of M(1.00 micron). Separator can be installed in ‘compact space inside a machine, before refrigerated dryer. after air compressor and ‘other applications. ASR: ‘Technical parameters: Tfpe 2): 0.7-1.6MPa ‘Working pressure: 0.7-1.6MPa fi: 100°C Max Operating temperature: 100 Max. PRBS PW MBRTR ronson | f= "4 a nr) Pressure correction factors KACERR Ite A (bar) Working pressure 9 2 19 18 IZBoE PLESI HM Ae7000,21 CRIA, WIEHMLALAFEE A 16bar, The above data are measured at 7 bar, 21°C , max. working pressures 16 bar. ‘8:12 Bf SA 1Om?/ min, TAFE ASbar. Example: You could choose the F0S1SPW when processing v=10/0. 75=13m?/minki i 338 #FOS1SPW. air rate is 10m?/min.working pressure § bar. Tube thread filter HARE RAR TR tovecees memes Coomaze roma Dsnnsens ce bch inn nA rows tat as? 203 cor 748 aca roves aust aos aor i748 onze roost AS Saar tH. aRUSE foo 4a ag 88 aor aT Ho atHSE oro 8S aa 288 148 —wOTOEY roo au 28 100s 287285 HTH ag er ee ee roveo 31190 125°«got 261 185——‘toe” rors 14a" Stats hae tas oreo F0265 142" 75 265 125 385 345 230 0265E" i room 44" 105 70 sass aro aa rors KG «SIS 7] stk a8 389 Fo745 a 244 745 170 684 634 570 O745E" =svene 0) FO780, 2 22.4 780 170 684 634 570 07806" ad rowoo 2m" 255600200 azo. 75279.—_—oBOOEY ee eee +1080 201050 20020752 ex0—_—ro0e" Frost 20 fost 200 azo 752 e3D—_—T0e” riaa0 963.1290 20082052700 eane* ris) «863 12802000). eso F487 4080 200 98k 1S 700 H880E* Pressure correction factors EAGER IE 5) 4) 5 6 7 8 Working pressure BERR 05 063 075 088 1 1.13 correction factors DLIESUBISEF7Dar 21 ORNS, MIR RAST AREA t6bar. SRE PL SEIBMS m/min, THERE Sar, MARIO. Otmg/m?. \V=9, 5/0. 75=4.7m!/ mine Bh BY i 38 SFO 1 BOM, (ERY ASA RA ‘ims HrOteoPsL AFOIOM. 4.25 wp 1 2 1 8 16 138 15 163. 1.75 ‘The above data are measured at 7 bar, 210 , max. working pressure is 16 bar. Example: You could choose the FO180H Ithairfiter then install FO180P or FO180M Filters primarily when processing air rate is 3.6m"/ min.working pressure 6 bar, residual oil 0.01mg/nv. Flange filter KEVBRMBRIR eoccvcce IRE External lange zee Diagram ORS om) MIRHES Com sie Flowate peace gosh uous tal Element Element A Som DN(mm) m/min cfm A BG DB mumber model FLO74S NGS 21.1745. «330684 «G34 5001S (0745 , FLog00 NEO 25.5 900364820752 5001800" cB FL1060 © DNEO «30-1060 «364-820-752 50011060" FL1260 ONO —«36.3.««*1280 «364820752 500112808" FLI650 DN100 «46.8. 1850364981815. 500 1——16SOE* waazaxD Sk238R Flange connection ele FL1400 DN100 «42,—«=«1400«525. 980782 500-2 —(OTABFE FL2100 DNI25 «63210025 1003-794 500 © 3—(O7ASFE A FL2e00 DN150 «84 ~—=«2800 «S77 1084 857 500 © (TAS FL3500 DN150 105-«3500 651 1123 862 500 5 (OTS 1 Fla4as N20 126-4448 «6511180 691 500-6 =A Fl5189 N20 147-5189 718 1246 944 500-7 ~—(OTASFE* FLs930 DN200 «168-5930 718 1246 944 500 «8S (TAS Fls672 DN200 1896872784 1262-936 500 «8 ~—(OTASFE FL7350 DN250 240-7350 «784 1317-964 500 ©—«10-——«(O7aSFE* seRERRD Fles42 DN250 2428542 «83414831122 50011. SSFE* FL10096 DN300 «286-1009. 876 1540 1132 500 13.—_—OTSSFE* FL11689 DN300—«330«11649 9981586 1146 500 15 ——O7SSFE* Pressure correction factors EABERM THEA) 9 4 5 6 7 8 8 wm 2 1 8 8 Working pressure BERR 05 063 075 088 1 113 125 138 16 163 1.75 188 2 219 Correction factors PLE WARE z7 Dar 21 CRIS, LAS HAA LIFE J) 16bar. 94 8 SEIBMGOM/ min, LAP AR AySbar, PRA EEO. O1mg/m?. 30/0. 75=40m?/ mink ie Wit He FLA GSOH, PIRI IE ALIA WRI BFL t6s0PR-AFLISSOM, ‘The above data are measured at 7 bar, 21°C , max. working pressures 16 bar. Example: You could choose the FL1650H Ithair filter then install FL1650P or FL1650M Filters primarily when processing air rate is 30m?/min.working pressure 5 bar, residual oi 0.01mg/mv. Stainless steel filter ASA BAM R Ye © eeeccevcccccce SNEGOTMRAOME, RRBRAAR MRM MA TEE. ASHATAALES, RAGA RAM ALE, RR MIOGI LABIAL, PUP SMM, MEM, RATES AN ERR, ARNG AE OR FeSLRE. RCRANOCRES, TUARTMTLORR, TAME ER OEM, RERETHSN RSS ILE RA. FRBFSAMIER OTL, Hi HREM. EIT. MERA BM I wi the quality of compressed airis high, the system should use stainless st pipes and stainless stee! filters. ATS provides stainless stee! filer with high precision manufacturing process, the housing is made of 304 or 316L stainless steel, the internal and external surface layer Is mirror polished, anti-corrosion, the structure conforms to the aerodynamic principle, to.ensure that the pressure drop of filter media is minimi The core is our highly efficient filter element, which can meet the needs of different Industries, can provide high filtration efficiency and very low pressure drop, and finaly and low operating costs. ty of industries with high gas requirements, such as semiconductor pharmaceutical and food processing tis wi ‘manufacturing, medical 38 stooet at 160 ase sore a ee 194 ‘810130 1112" 130 380 293 270 194 T0270 460 373 aoa a cia 250 322 T0520 2412" 148 520 8 o—l T1400 DN100 1483 525 880 782 77 g CEEEEEEI 872800 DN150 2965 TEP 064 ahh PP bE EE 89 sT44a8 DN200 126 4448 6511180 i bhbhepy m8 1286 75930 DN200 168 5930 o Stainless steel aseptic air filter(can pass through gas) ARH BR Ba 2S UB BS (FT VL RA) cccccecccccce FEO RAH, QFLIBTUH, AHSMMRARR CBRE ARS MH, LRLIERR, SABIFDA, CUPRA. ARRGREM UNS, ARANETA, VAERRH A HS, BM, ICM. RRM, ALERT, THI. u BERMBAD ROMA (PTFE) BBM, RAT, EFSR, MILER RBM RBAI~LDN, BRIO, $AN20-40C HAA AEMRM. Inthe industries of bio-pharmacy, food and beverage, electronics and chemical industry, compressed air filtration needs to be sterile or high-purity filtration to meet the process requirements and meet the standards of FDAand GMP, provides stainless steo! sterilizing filter, the housing is made of 304 or 316 sanitary grade stainless steel, the internal and external surface layer mirror polishing treatment, anti-corrosion, no dead corner, no residue, equipped with quick installation chuck, easy tomaintain. The filter element is made of polytetrattucroethylene (PTFE) sterilizing paper with super large filtration area. Quick-mounted structure, easy to install, according to the 7 actual situation once week or twice a month, 30 minutes each time, using 120°C-140'C Glean steam sterilzaton regulary. ia BRSR Technical parameters; - BEA FBB: 0. 05-1. OW, Pressure.ange: 0.05-1.0MPa MMMM. 0. o1un Filtration precision. 0.01um HHBLE: 99.908 Filtration efficiency. 99.99% HARM: 5-000 Inlet temperature: 5-80°C SERIA: 2-60. Environment temperature: 2-60°C ; gnrt im RF om) - fines mace! Conn. size Flow rate Dimensions poem ae BSP-F om'/min cfm KBE B a as “ STOOZIAF si 06 21 tor 250383 1 @ STOOSSAF 31a" 15 53101250383 1 STOOTBAF , 22-78) 10125088 1 STO1OZAF * 29 102,101 250788 1 i STOIDAF 1-1/2" 49° 1901250738 1 STORUAF 1-412" 57 200-219 380488 3 Installation in series RRA This compact assembly design will meet most customers demand -Itis suitable for end of point usage and without installation of, .ded connector. ATRRESMORMER, RIV TRAM AA, EASHRULOMSM AAS, TUES, RRM RELE. 11. Medical vacuum decontamination filter EARS RRR ERASHEULSTEATERARRBORE RE. ERONSMIRRRDKLERGRORRRE. ME MIREAFAR MIN AAO MMAR, SH RRO ER, Raw mO EZ AT SH A 9 a HR AmM SR. RELA DNERTRLAMOMR SMSO ERASUBEARRAB ASHE, AARBIONE, i A Ek A LE AL eit. Medical vacuum sterilizing filter is mainly used in the negative pressure system of sterile hospital wards. ‘The vacuum suction systemis an essential eq hospitals. The vacuum suction system attracts bacteri ‘gases from the operating room and discharges them into the atmosphere, which pollutes the surrounding environment and ‘The vacuum sterilizing calch and collect bacter ‘The sterilizing filters also suitable for clean and sterile laboratory ané workshop. ‘The medical vacuum filter housing is made of aluminum alloy, the inner surface layers electrophoretic, and the corrosion resistance is strong. External surface powder spraying ‘treatment, coating quality, corrosion resistance, mechanical properties, FoozoMy 1/2" 95 Foo7oMy. 3/4" 95 iii vii row FT — = rozesMy 41 18 se 125 —_ —_ os 800 Fresoy ot 100 880200 Pressure correction factors AERA 18 207 174 160 -0020MV 235 160 0070MV ite o125Mv 100 385 oz6sMv 504455 ostsMv oBse same (aul 820 752 160 1060MV 981915 1650MVv LitEA ten, Wiorking press: 09 08 07 06 08 hb AO HEF te tbar.21CRT AE. ‘SB Hf: MEI MGOM/n, THF I0.6bar, \v=80/0. 6=133m?/hiVi8i8 Bid 28 EFOTASMV. 12. oa 03 02 04 008 | 092 The above data are measured at 1 bar, 21°C Example: You could choose the FO745MV when processing alrrate is 80m*/n.working pressure 0.6 bar. Depth Oil removal filters RIS Ui ith ik iB 8S ALAS R ot ae © Ce eeeecccccccs CORI A ait AMM Th — NER RIE TERR, ANKE Be, RABES, HameweA. PERENSRRERSOLAHS, a. MRT, AVERT. BT. meeTeLe. Thefilterelementof CP series deep degreasing filter consists of an activated carbon tube and a dust-removing filter element. Double function combination, with the advantages of saving space and cost. Itis widely used in applications requiring high oll content, such as spraying industry, laser cutting industry, pharmaceutical industry, precision electronics industry, etc. kom: Technical parameter Lit: 1.6MPa Mex Working prossure:1.6mpa Max. iH: 0.003ppm Filtration precision: 0,003ppm TfPeRm. 60°C Max Operating temperature: 60 Max. Pressure correction factors EABERM fet oer) 5 112 130 141816 Working pressure LLMIESEFETO0r21CH MB, MIRRMATAGIG A t6ber. The above data are measured a7 bar, 20°C, max. working pressure is 16 bar. sR |L-5L IB MIM/ min, THEE ASder, Peak BO. 003mg/m?, Example: You could choose the FO100CP when processing ane ; air rate is 2m?/min.working pressure 5 bar, residual oil \V=2/0. 75°2.7m?/mini FO100CP. i area 13. Energy efficiency of filters HE A BE EGS DRA TARA RARMANED AA, HARASS ZAM HOPE, SMO RDA RED LIFES WM, MOKED UE IRIE AY efit. RENT RASHEOR ITS AERA ASTOIAMOER AMT SPREAD, KE, EORTC TRAIN , RE, Bat CMM LRER RNS, seem w: ALERT. STiRAPRONCITREREiK , HeAMONRIRtRERESLL OF ERI EIRIEASAU NOE ORRBARMEASS eo RPMI TRAM CRP THRE @ OLENA REET AMMA FRASER © SAMAR TREK TON RSE EIRAA © ETA © ERRATA © ar7. SALIRRRNISIRn STR — 1 ROR LAF, FPTEMTERDA AFR F 2 RE I AS CRA CEPRAREET OEE © sername seme may THBRETRER MER LOHOTSERI DAHAER REMIT ? HFT POTTER LE MRO HASTE NMR RMS ASML THES SA, ORGASMS , AFL ERETA AERIMEHAMERTREERM , MOTARRNERA PERRIS AMRRELLS , ROE T LET, FOUKM-ANA THERES: ‘The pressure loss of compressed air filter consists of inherent pressure loss and increasing pressure loss, ‘The inherent pressure loss is caused by the filter housing structure and the interface between the housing and the filter core, The incremental pressure loss is caused by the clogging of the filter core. Providing the optimized ‘compressed air channels the key to reduce the system operating cost. Filter connection:The same filter has a variety of Interface sizes to choose from, and ean meet bath eystem and flowrate requirements, increasing customer selection opportunities, and reducing installation costs. Compact and light: advanced filter core design concept Makes filter smaller and more compact, which allow filters 10, be installed even in narrow spaces. Complete anticorrosion: filter housing are all electrophoretic, this excellent anticorrosion performance provides 10 years. of quality assurance. Benefits of timelelementsy replace of ‘*Ensure high quality compressed air «Protection of adsorption aryer’s adsorption bed «Protection of downstream equipment sduction in operating costs elmproving productivity and profitability What are the consequences of not replacing the filter Will cause damaging to the adsorption bed of adsorption dryer, resulting in unplanned replacement ofthe desiccant beads *Corrosion of gas storage tanks and pipes in transmission networks «Valves and air motors blocked and frozen «Discharges from valves and cylinders create an unhealthy working environment, potential staffing atrtion as well as financial compensation due to healthissue *Machine will be damaged Ineffective production processes *Low eligibility cate Increase manufacturing cost and downtime. The filter is equipped with a differential pressure gauge and the pointeri in the green area, but why do we still require to change the elements? Reason boing is that the filler fibers inthe filter loment become brittle over a period of time, even a small hole can cause the filter medium to break and thus the contaminants will enter the downstream of the compressed air system without filtering. If this happens, the pointer on the gauge will always be in the green area due to the small pressure difference between the front and back of the filter, the filter element will not be replaced in time until the user found contaminants downstream. Please note that even ifthe elementis replaced, contamination will still be remained in the downstream pipeline for a considerable period of time. also specializing in manufacturing compatible and custom-made filters and elements SHEERS WRECKS EH 14,

You might also like