You are on page 1of 2

12/17/2019 Test Cell Results

E T [TXX02072] D 17, 2019


(TXX02072)-E (E9W00241)-M (DM300528)- For Help Desk Phone Numbers Click here
T
(/tmi/tmihome/TMIContactInfo.htm)

Sales Model: C13


TMI Load Date: 31Jan2018
Built Date: 22Jan2018 Tested Date: 31Jan2018
Shipped Date: 05Feb2018 Tested: HZ
Plant: Seguin Cell Number: 106

Show 50 entries Search:

Test Element Eng Updates Test Value Test Spec Value Measure

Spec Number 4150214 4150214

Arrangement Number 4220048 4220048

Corr Fl Power 370 R 370 HP

Speed 2,000 2,000 RPM

COR FL FUEL RATE 19.0 R 18.3 GAL/HR

CSFC 0.364 0.349 LB/HP-HR

Adj Boost 47.7 46.8 IN HG

Fuel Pressure 112 106 PSI

Oil Pressure 72 68 PSI

TQ COR FUEL RATE 15.4 R 14.8 GAL/HR

TQ CK CSFC 0.352 0.337 LB/HP-HR

TQ CK ADJ BST 46.8 43.7 IN HG

Torq Ck Speed 1,205 1,200 RPM

TQ CK COR TQ 1,355 R 1,355 LB.FT

Low Idle Speed 799 800 RPM

Low Idle Oil Pressure 34 33 PSI

High Idle Speed 2,147 2,150 RPM

FL Static Fuel Setting 0.151 0.151 IN

FT Static Fuel Setting 0.211 0.211 IN

Full Load Setting(FLS) Intercept -15 R -5

Full Torque Setting(FTS) Slope 31 R 14

Ataac Delta Pressure 0.13 PSI