You are on page 1of 22

DATA SHEET

GLOBAL S
2 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com
GLOBAL S
The Coordinate Measuring Machine that Pushes Productivity Further

The GLOBAL S coordinate measuring machine (CMM) series from with three performance levels: Green, Blue and Chrome, to suit the
Hexagon Manufacturing Intelligence combines smart technologies requirements of any application. EPS machines offer customers
delivering superior measurement performance and enhanced the option to select their main productivity driver and configure the
productivity for the unique needs of any production environment. CMM for throughput, precision, flexibility or shop floor capability. The
Designed by Pininfarina and powered by Hexagon’s Enhanced CMM range also supports fully-customised setups to ensure that
Productivity Series (EPS) concept, GLOBAL S brings together GLOBAL S is universally applicable and drives continuous productivity
enhanced technologies to form an optimal measurement solution improvements.

GLOBAL S– HOW TO CHOOSE THE RIGHT SYSTEM

PERFORMANCE

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 3


GLOBAL S 05.YY.05: OVERALL DIMENSIONS

Y LX 1)

LZ
678 2)
Z

130

PH
108 PY 160 61 X 70

LY 908

HP-S-X3C HH-AS6-T5° HH-A-T2.5°

65 65 65

CMM Ram
77.6
101

120
151
34.6
58.6

Measuring Range Overall Dimensions Surface Plate


Max. Part CMM
mm (in) mm (in) mm (in)
Weight Weight
Models
approx.
X Y Z LX 1) LY LZ PH PY kg (lb) kg (lb)

500 500 500 1024 1255 2540 800 990 230 510
05.05.05
(19.69) (19.69) (19.69) (40.31) (49.41) (100) (31.50) (38.98) (507.06) (1124.36)

500 700 500 1024 1455 2540 800 1190 230 625
05.07.05
(19.69) (27.56) (19.69) (40.31) (57.28) (100) (31.50) (46.85) (507.06) (1377.89)

1)
With Shop Floor bellows: LX + 21 mm (.83 in)
2)
With Shop Floor bellows: 649 mm (25.55)

4 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com


GLOBAL S 07.10.07: OVERALL DIMENSIONS

Y LX 1)

LZ
839 2)
Z

140

PH
90 PY 168 66 X 60

LY 1135

HP-S-X3C HH-AS8-T5° HH-A-T5° HH-AS8-T2.5°

80 80 80 80
15.2

CMM Ram
56.4
75.4

74.5

96.2
98.5
101

117
32.4

65.2

Measuring Range Overall Dimensions Surface Plate


Max. Part CMM
mm (in) mm (in) mm (in)
Weight Weight
Models
approx.
X Y Z LX 1) LY LZ PH PY kg (lb) kg (lb)

700 1000 660 1277 1908 2777 700 1650 900 1265
07.10.07
(27.56) (39.37) (25.98) (50.28) (75.12) (109.33) (27.55) (64.96) (1984.16) (2788.85)

1)
With Shop Floor bellows: LX + 12 mm (.47 in)
2)
With Shop Floor bellows: 796 mm (31.34 in)

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 5


GLOBAL S 09.YY.08: OVERALL DIMENSIONS
Y LX 1)

LZ
936 2) 4)
946 3) 5)
Z

117

PH
90 2) PY 165 2) 66 2) X 60 2)
213 3) 213 3) 70 3) 69 3)
LY 1359 2)
1457 3)

HH-AS8-T5° HH-AS8-T2.5° HH-AS8-H2.5°

802)/883) 802)/883)
80 /88
2) 3)
32.4

15.2
65.2
15.2

50
CMM Ram

31
56.4
75.4

96.2

70.5

HP-S-X3C HP-S-X5/X5 HD 3) 90.5

802)/883) 883)
CMM Ram
101

168.5

191.5

Overall
Measuring Range Surface Plate
Dimensions Max. Part CMM
mm (in) mm (in)
mm (in) Weight Weight
Models
approx.
X Y Z6) LX 1) LY LZ PH PY kg (lb) kg (lb)

1477 2165 3027 1910 1700


900 1200 800 (58.15) 2) (85.24) 2) (119.17) 2) 700 (75.20) 2) 1300 (3747.86) 2)
09.12.08
(35.43) (47.24) (31.50) 1598 2455 3150 (27.56) 2030 (2866) 2350
(62.91) 3) (96.65) 3) (124.02) 3) (79.92) 3) (5180.86) 3)
1477 2465 3027 2210 1900
900 1500 800 (58.15) 2) (97.05) 2) (119.17) 2) 700 (87.01) 2) 1500 (4188.78) 2)
09.15.08
(35.43) (59.06) (31.50) 1598 2755 3150 (27.56) 2330 (3306.93) 2650
(62.91) 3) (108.46) 3) (124.02) 3) (91.73) 3) (5842.25) 3)
1477 2965 3027 700 2710 2300
900 2000 800 (58.15) 2) (116.73) 2) (119.17) 2) (27.56) 2) (106.69) 2) 1800 (5070.63) 2)
09.20.08
(35.43) (78.74) (31.50) 1598 3255 3175 725 2830 (3968.32) 3350
(62.91) 3) (128.15) 3) (125) 3) (28.54) 3) (111.42) 3) (7385.49) 3)
1)
With Shop Floor bellows: LX + 16 mm (.63 in); 4)
With Shop Floor bellows: 906 mm (35.67 in)
2)
GLOBAL S Green 5)
With Shop Floor bellows: 922 mm (36.30 in)
3)
GLOBAL S Blue and Chrome 6)
With HP-S-X5/X5 HD probe heads, Z travel = 730 mm (28.74 in)

6 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com


GLOBAL S 12.YY.10: OVERALL DIMENSIONS

Y LX 1)

LZ
1170 2)
Z

150

PH
213 PY 213 70 X 69

LY 1757

HH-AS8-T5° HH-A-T5° HH-AS8-T2.5° HH-AS8-H2.5° HP-S-X5/X5 HD 3)

88 88 88 88
88
32.4

15.2

15.2

50
CMM Ram
56.4
75.4

96.2
74.5
98.5
117

168.5
65.2

191.5
31

70.5

90.5

Overall
Measuring Range Surface Plate
Dimensions Max. Part CMM
mm (in) mm (in)
mm (in) Weight Weight
Models
approx.
X Y Z 4) LX 1) LY LZ PH PY kg (lb) kg (lb)

1200 1500 1000 1898 2905 3513 625 2480 1800 3850
12.15.10
(47.24) (59.06) (39.37) (74.72) (114.37) (138.31) (24.61) (97.64) (3968.32) (8487.80)

1200 2200 1000 1898 3605 3488 600 3180 2250 5750
12.22.10
(47.24) (86.61) (39.37) (74.72) (141.93) (137.32) (23.62) (125.20) (4960.40) (12676.58)

1200 3000 1000 1898 4405 3513 625 3980 2250 7650
12.30.10
(47.24) (118.11) (39.37) (74.72) (173.43) (138.31) (24.61) (156.69) (4960.40) (16865.36)

1)
With Shop Floor bellows: LX + 17 mm (.67 in)
2)
With Shop Floor bellows: 1162 mm (45.75 in)
3)
GLOBAL S Blue and Chrome
4)
With HP-S-X5/X5HD probe head, Z travel = 970 mm (38.19 in)

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 7


GLOBAL S 15.YY.10: OVERALL DIMENSIONS

Y LX 1)

LZ
1170 2)
Z

150

PH
213 PY 213 70 X 69

LY 2057

HH-AS8-T5° HH-A-T5° HH-AS8-T2.5° HH-AS8-H2.5° HP-S-X5/X5 HD 3)

88 88 88 88 88
32.4

15.2

15.2

CMM Ram 50
56.4
75.4

96.2
74.5
98.5
117

168.5
65.2

191.5
31

70.5

90.5

Overall
Measuring Range Surface Plate
Dimensions Max. Part CMM
mm (in) mm (in)
mm (in) Weight Weight
Models
approx.
X Y Z 4) LX 1) LY LZ PH PY kg (lb) kg (lb)

1500 2200 1000 2198 3605 3488 600 3180 2250 6700
15.22.10
(59.06) (86.61) (39.37) (86.54) (141.93) (137.32) (23.62) (125.20) (4960.40) (14770.97)

1500 3000 1000 2198 4405 3513 625 3980 2250 8930
15.30.10
(59.06) (118.11) (39.37) (86.54) (173.43) (138.31) (24.61) (156.70) (4960.40) (19687.28)

1)
With Shop Floor bellows: LX + 17 mm (.67 in)
2)
With Shop Floor bellows: 1162 mm (45.75 in)
3)
GLOBAL S Blue and Chrome
4)
With HP-S-X5/X5 HD probe heads, Z travel = 970 mm (38.19 in)

8 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com


GLOBAL S: MINIMUM DOOR OPENING REQUIREMENTS

Machine maximum overall dimensions


Width Height 1)
Standard Size Frames
mm (in) mm (in)

5.5.5 - 5.7.5 1095 (43.11) 1490 (58.66)

7.10.7 1340 (52.75) 1655 (65.15)

9.12.8 - 9.15.8 - 9.20.8 1540 (60.62) 2) / 1665 (65.55) 3) 2020 (79.52 2)/ 2065 (81.29) 3)

12.15.10 - 12.22.10 - 12.30.10 1965 (77.36) 2305 (90.74)


15.22.10 - 15.30.10 2265 (89.17) 2305 (90.74)

1)
Minimum Height is listed w/o the CMM stand for Global 05.YY.05 and 07.YY.07 series and w/o pedestals for the Global 09.YY.08 thru15.YY.10 series
Dimensions shown are from the highest point at the top of the CMM to the lowest point on the CMM as in shipped condition
Dimensions shown do not include lifting equipment
Dimensions shown are with 1 inch minimum clearance all around
2)
For GLOBAL S Green
3)
For GLOBAL S Blue and Chrome

GLOBAL S: TECHNICAL CHARACTERISTICS

X: Micromachined anodized light alloy extrusion


Mechanical Frame Y: Integral dovetail guideways, machined into the table
Z: Micromachined anodized light alloy extrusion
Material: Granite
Y
Flatness: according to DIN 876/III = =

Part Locking: threaded inserts M8 x 1.25

=
Diagonally staggered hole pattern:

X
GLOBAL S 05.YY.05: X = 350 mm (13.78 in);

=
Surface Plate
Y= 150 mm (5.90 in)
GLOBAL S 07.YY.07: X = 300 mm (11.81 in);
Y= 300 mm (11.81 in)
GLOBAL S from 09.YY.08: X = 350 mm (13.78 in);
Y= 350 mm (13.78 in)

Sliding System Air bearings on all axes

Measuring System METALLUR® linear scales. System Resolution: 0.005 μm

Extended temperature 16 - 26 °C: Multi-sensor technology


Temperature Compensation
Shop floor temperature 15 - 30°C: Structural multi-sensor technology

Ram Counterbalance Pneumatic, adjustable

DC800, DC800, DC 241,


Controller
IP54 IP54 IP54

Supply Requirements Power 100/120/220/240 V ± 10% - 50/60 Hz - 1.6 KVA

Air 0.5 MPa minimum - Class 4 according to ISO 8573/1

Consumption Power 0.5 KVAh 0.5 KVAh 0.35 KVAh

Air 70 Nl/min (for 05.YY.05); 90 Nl/min (for all other models)

Ambient temperature: 10 °C - 40 °C / 50 - 104 °F


Operating Specifications
Relative humidity: 20% - 90 % non-condensing

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 9


GLOBAL S: ISO SPECIFICATIONS

Scanning probe heads HP-S-X1C, HP-S-X5/X3 05.YY.05 07.YY.07 09.YY.08 12.YY.10 15.YY.10
Articulating head with HP-S-X1 scanning probe

MPE(E0/E150) 1) - (18 °C - 22 °C / 64 °F - 71 °F) 1.4 + L/333 1.3 + L/333 1.3 + L/333 2.0 + L/333 2.1 + L/333

MPE(E0/E150) 1) - (16 °C - 26 °C / 61 °F - 79 °) 1.6 + L/222 1.5 + L/250 1.6 + L/250 2.4 + L/200 2.5 + L/200

MPL(R0) 1.2 1.2 1.2 1.7 1.7

MPE(PFTU) 1.4 1.4 1.3 1.7 1.8

MPE(THP)/MPT(t) - High accuracy 2) 2.1/30 2.0/30 2.0/35 2.5/35 2.9/35

MPE(THP)/MPT(t) - High throughput 2) 2.1/30 2.0/30 2.3/25 3.5/25 3.5/25

MPE(THN)/MPT(t) - Non-predefined path 2) 2.1/50 2.0/50 2.0/50 2.0/50 2.9/50

RONt (MZCI) 3) 1.4 1.4 1.4 1.7 1.8

MPE(E0/E150) 1) - (18 °C - 22 °C / 64 °F - 71 °F) 1.4 + L/333 1.4 + L/333 1.4 + L/333 2.1 + L/333 2.2+L/333

MPE(E0/E150) - (16 °C - 26 °C / 61 °F - 79 °F)


1) 1.6 + L/222 1.6 + L/250 1.7 + L/250 2.5 + L/200 2.5 + L/200

MPE(E0/E150) - (16 °C - 26 °C / 61 °F - 79 °F)


1) 4)
– 1.4 + L/294 1.4 + L/285 2.1 + L/277 –
MPE(E0/E150) 1) - (15 °C - 30 °C / 59 °F - 86 °F) 4)
– 1.4 + L/263 1.4 + L/256 2.1 + L/250 –
MPL(R0) 1.2 1.2 1.2 1.7 1.8

MPE(PFTU) 1.4 1.4 1.4 1.8 2.0

MPE(THP)/MPT(t) 2) 2.5/45 2.5/45 2.5/45 3.1/45 3.5/45

MPE(E0/E150) 1) - (18 °C - 22 °C / 64 °F - 71 °F) 1.5 + L/333 1.5 + L/333 1.8 + L/333 2.4 + L/333 –

MPE(E0/E150) - (16 °C - 26 °C / 61 °F - 79 °F)


1) 1.7 + L/222 1.7 + L/250 2.1 + L/250 2.8 + L/200 –
MPE(E0/E150) - (16 °C - 26 °C / 61 °F - 79 °F)
1) 4)
– 1.5 + L/294 – – –
MPE(E0/E150) 1) - (15 °C - 30 °C / 59 °F - 86 °F) 4) – 1.5 + L/263 – – –
MPL(R0) 1.4 1.4 1.7 1.9 –
MPE(PFTU) 1.6 1.6 1.8 2.4 –

MPE(THP)/MPT(t) 2) 2.9/45 2.9/45 2.9/45 4.0/45 –

Chrome Performance Level Blue Performance Level Green Performance Level

Max. Permissible Error MPE (μm) and Max. Permissible Limit MPL (μm) according to ISO 10360-2:2009:
- Volumetric length measuring error: MPE(E0/E150)
- Repeatability range: MPL(R0)
Max. Permissible Error MPE (μm) according to ISO 10360-5:2010:
- Single stylus form error: MPE(PFTU)
Max. Permissible Error MPE (μm) and Max. Permissible Time MPT (s) according to ISO 10360-4: 2000:
- Single stylus form error, scanning: MPE(THP)/MPT(t)
- Single stylus form error, scanning - Non-predefined path: MPE(THN)/MPT(t)
ISO 12181-1: 2011 (VDI/VDE 2617 part 2.2): Form measurement error (μm): RONt (MZCI)
Probe Configuration:
• HP-S-X5/3C: stylus length 60 mm (2.36 in), tip diameter 5 mm (.20 in)
• HP-S-X1/X1C: stylus length 50 mm (2 in), tip diameter 5 mm (.20 in)
1)
MPE(E0/E150) specifications are to be formally understood as MPE(E0/E150)* for the case where non-normal CTE material calibrated test lengths are used.
Length unit measure (L) in mm.
2)
MPE(THP/THN) and MPT(t): test sphere placed in the centre of measuring volume
3)
RONt test on Ø 50 mm (2 in) ring gauge. Ring axis parallel to machine vertical axis, gauge placed in the centre of measuring volume
4)
For Shop Floor packages only.

10 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com


GLOBAL S: ISO SPECIFICATIONS

Articulating head with HP-THD / TP200 05.YY.05 07.YY.07 09.YY.08 12.YY.10 15.YY.10
high precision trigger probe

MPE(E0/E150) 1) - (18 °C - 22 °C / 64 °F - 71 °F) – 1.7 + L/333 1.7 + L/333 2.4 +L /333 2.5 + L/333

MPE(E0/E150) 1) - (16 °C - 26 °C / 61 °F - 79 °F) – 1.9 + L/250 1.9 + L/250 2.7 + L/200 2.8 + L/200
MPL(R0) – 1.7 1.7 2.7 2.8

MPE(PFTU) – 1.7 1.7 2.2 2.2

MPE(E0/E150) 1) - (18 °C - 22 °C / 64 °F - 71 °F) 1.7 + L/333 1.7 + L/333 1.9 + L/333 2.5 + L/333 2.5 + L/333

MPE(E0/E150) 1) - (16 °C - 26 °C / 61 °F - 79 °F) 1.9 + L/222 1.9 + L/250 2.1 + L/250 2.8 + L/200 2.8 + L/200
MPE(E0/E150) 1) - (16 °C - 26 °C / 61 °F - 79 °F) 2) – 1.7 + L/294 1.9 + L/285 2.5 + L/277 –
MPE(E0/E150) - (15 °C - 30 °C / 59 °F - 86 °F)
1) 2)
– 1.7 + L/263 1.9 + L/256 2.5 + L/250 –
MPL(R0) 1.9 1.9 2.1 2.7 2.8
MPE(PFTU) 1.9 1.9 1.9 2.2 2.2

MPE(E0/E150) 1) - (18 °C - 22 °C / 64 °F - 71 °F) 1.7 + L/333 1.7 + L/333 1.9 + L/333 2.5 + L/333 –
MPE(E0/E150) - (16 °C - 26 °C / 61 °F - 79 °F)
1)
1.9 + L/222 1.9 + L/250 2.1 + L/250 2.8 + L/200 –
MPE(E0/E150) 1) - (16 °C - 26 °C / 61 °F - 79 °F) 2) – 1.7 + L/294 – – –
MPE(E0/E150) 1) - (15 °C - 30 °C / 59 °F - 86 °F) 2) – 1.7 + L/263 – – –
MPL(R0) 1.9 1.9 2.1 2.7 –
MPE(PFTU) 1.9 1.9 1.9 2.5 –

Articulating head with HP-TM trigger probe. 05.YY.05 07.YY.07 09.YY.08 12.YY.10 15.YY.10

MPE(E0/E150) 1) - (18 °C - 22 °C / 64 °F - 71 °F) 1.9 + L/333 1.9 + L/333 2.1 + L/333 2.7 + L/333 –
MPE(E0/E150) - (16 °C - 26 °C / 61 °F - 79 °F)
1)
2.2 + L/222 2.2 + L/250 2.4 + L/250 3.1 + L/200 –
MPE(E0/E150) - (16 °C - 26 °C / 61 °F - 79 °F)
1) 2)
– 1.9 + L/294 2.1 + L/285 2.7+ L/277 –
MPE(E0/E150) 1) - (15 °C - 30 °C / 59 °F - 86 °F) 2) – 1.9 + L/263 2.1 + L/256 2.7+ L/250 –
MPL(R0) 1.9 1.9 2.1 2.7 –
MPE(PFTU) 2.0 2.0 2.0 2.6 –

MPE(E0/E150) 1) - (18 °C - 22 °C / 64 °F - 71 °F) 1.9 + L/333 1.9 + L/333 2.1 + L/333 2.7 + L/333 –
MPE(E0/E150) - (16 °C - 26 °C / 61 °F - 79 °F)
1)
2.2 + L/222 2.2 + L/250 2.4 + L/250 3.1 + L/200 –
MPE(E0/E150) - (16 °C - 26 °C / 61 °F - 79 °F)
1) 2)
– 1.9 + L/294 – – –
MPE(E0/E150) 1) - (15 °C - 30 °C / 59 °F - 86 °F) 2) – 1.9 + L/263 – – –
MPL(R0) 1.9 1.9 2.1 2.7 –
MPE(PFTU) 2.0 2.0 2.0 2.7 –

Chrome Performance Level Blue Performance Level Green Performance Level

Max. Permissible Error MPE (μm) and Max. Permissible Limit MPL (μm) according to ISO 10360-2:2009:
- Volumetric length measuring error: MPE(E0/E150)
- Repeatability range: MPL(R0)
Max. Permissible Error MPE (μm) according to ISO 10360-5:2010:
- Single stylus form error: MPE(PFTU)
Probe Configuration:
• HP-THD: Standard force module, stylus length 10 mm (.39 in), tip diameter 4 mm (.16 in)
• TP200: Standard force module, stylus length 10 mm (.39 in), tip diameter 4 mm (.16 in)
• HP-TM: Standard Force Module, stylus length 10 mm (.39 in), tip diameter 4 mm (.16 in)
1)
MPE(E0/E150) specifications are to be formally understood as MPE(E0/E150)* for the case where non-normal CTE material calibrated test lengths are used.
Length unit measure (L) in mm.
2)
For Shop Floor packages only.

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 11


GLOBAL S: ASME B89 SPECIFICATIONS - 05.YY.05 - 09.YY.08

Scanning probe heads HP-S-X1C, HP-S-X5/X3 05.YY.05 07.10.07 09.12.08 09.15.08 09.20.08
Articulating head with HP-S-X1 scanning probe

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (3.0, 3.0, 2.5) (3.0, 3.0, 2.5) (3.0, 3.0, 2.5) (3.5, 3.5, 3.0) (3.5, 3.5, 3.0)

Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 5.0 [400] 6.0 [550] 6.4 [750] 6.4 [750] 6.4 [750]

LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (4.0, 4.3, 3.5) (4.3, 4.9, 3.8) (4.7, 5.3, 4.0) (5.2, 6.4, 4.0) (5.2, 7.3, 4.5)

Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 5.5 [400] 6.7 [550] 7.4 [750] 7.4 [750] 7.4 [750]

R 1.4 1.4 1.4 1.4 1.4

MPE(THP)/MPT(t) - High accuracy 1) 2.1/30 2.0/30 2.0/35 2.0/35 2.0/35

MPE(THP)/MPT(t) - High throughput 1) 2.1/30 2.0/30 2.3/25 2.3/25 2.3/25

MPE(THN)/MPT(t) - Non-predefined path 1) 2.1/50 2.0/50 2.0/50 2.0/50 2.0/50

RONt (MZCI) 2) 1.4 1.4 1.4 1.4 1.4

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (3.0, 3.0, 2.5) (3.0, 3.0, 2.5) (3.5, 3.5, 2.5) (3.5, 3.5, 3.0) (3.5, 3.5, 3.0)

Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 5.0 [400] 6.0 [550] 6.4 [750] 6.4 [750] 6.4 [750]

LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (4.0, 4.3, 3.5) (4.3, 4.9, 3.8) (4.7, 5.3, 4.0) (5.2, 6.4, 4.5) (5.2, 7.3, 4.5)

Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 5.5 [400] 6.7 [550] 7.4 [750] 7.4 [750] 7.4 [750]

LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 3) – (3.7, 4.0, 3.2) (4.1, 4.4, 3.3) (4.4, 5.0, 3.5) (4.4, 5.4, 3.8)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 3)
– 6.4 [550] 6.9 [750] 6.9 [750] 6.9 [750]

LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 3)


– (4.6, 5.0, 4.0) (5.4, 5.7, 4.2) (5.7, 6.4, 4.6) (5.7, 7.0, 4.9)

Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 3) – 6.8 [550] 7.5 [750] 7.5 [750] 7.5 [750]

R 1.4 1.4 1.4 1.4 1.4

MPE(THP)/MPT(t) 2.5/45 2.5/45 2.5/45 2.5/45 2.5/45

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (4.0, 4.0, 3.0) (4.0, 4.0, 3.0) (4.0, 4.0, 3.0) (4.0, 4.5, 3.0) (4.0, 4.5, 3.0)
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 7.0 [400] 8.0 [550] 9.0 [750] 9.0 [750] 9.0 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (5.0, 5.3, 4.0) (5.3, 5.9, 4.3) (5.7, 6.3, 4.5) (5.7, 7.4, 4.5) (5.7, 8.3, 4.5)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 7.5 [400] 8.7 [550] 10.0 [750] 10.0 [750] 10.0 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) SF 3)
– (4.0, 4.0, 3.0)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 3) – 8.4
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) SF 3)
– (5.1, 5.1, 3.8)
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 3)
– 8.8
R 1.7 1.7 1.7 1.7 1.7
MPE(THP)/MPT(t) 1) 2.9/45 2.9/45 2.9/45 2.9/45 2.9/45

Chrome Performance Level Blue Performance Level Green Performance Level

Accuracy performance specifications according to ASME B89.4.1 b-2001:


- Linear displacement accuracy in X, Y, and Z (µm): LDA
- Volumetric accuracy performance (µm), where L is ball bar length in mm: Av [L]
- Repeatability (µm)
Max. Permissible Error MPE (µm) and Max. Permissible Time MPT (s) according to ISO 10360-4: 2000:
- Single stylus form error, scanning: MPE(THP)/MPT(τ)
- Single stylus form error, scanning - Non-predefined path: MPE(THN)/MPT(τ)
ISO 12181-1: 2011 (VDI/VDE 2617 part 2.2): Form measurement error (µm): RONt (MZCI)
Probe Configuration:
• HP-S-X5/X3: stylus length 60 mm (2.36 in), tip diameter 5 mm (.20 in)
• HP-S-X1/X1C: stylus length 50 mm (2 in), tip diameter 5 mm (.20 in)
1)
MPE(THP/THN) and MPT(t): test sphere placed in the center of measuring volume
2)
RONt test on Ø 50 mm (2 in) ring gauge. Ring axis parallel to machine vertical axis, gauge placed in the center of measuring volume
3)
For Shop Floor packages only.

12 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com


GLOBAL S: ASME B89 SPECIFICATIONS - 12.YY.10 - 15.YY.10

Scanning probe heads HP-S-X1C, HP-S-X5/X3 12.15.10 12.22.10 12.30.10 15.22.10 15.30.10
Articulating head with HP-S-X1 scanning probe

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (3.0, 3.0, 3.0) (3.0, 4.0, 3.0) (3.0, 6.0, 3.0) (5.0, 5.0, 4.0) (5.0, 6.0, 4.0)

Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 7.9 [900] 7.9 [900] 7.9 [900] 10.0 [900] 10.0 [900]

LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (5.3, 5.9, 4.9) (5.3, 8.2, 4.9) (5.3, 11.7, 4.9) (7.9, 9.2, 5.9) (7.9, 11.7, 5.9)

Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 9.1 [900] 9.1 [900] 9.1 [900] 11.2 [900] 11.2 [900]

R 1.7 1.7 1.7 1.9 1.9

MPE(THP)/MPT(t) - High accuracy 1) 2.5/35 2.5/35 2.5/35 2.9/35 2.9/35

MPE(THP)/MPT(t) - High throughput 1) 3.5/25 3.5/25 3.5/25 3.5/25 3.5/25

MPE(THN)/MPT(t) - Non-predefined path 1) 2.0/50 2.0/50 2.0/50 2.9/50 2.9/50

RONt (MZCI) 2) 1.7 1.7 1.7 1.8 1.8

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (3.5, 3.5, 3.0) (3.5, 4.0, 3.0) (3.5, 6.0, 3.0) (5.0, 5.0, 4.0) (5.0, 6.0, 4.0)

Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 7.9 [900] 7.9 [900] 7.9 [900] 10.0 [900] 10.0 [900]

LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (5.3, 5.9, 4.9) (5.3, 8.2, 4.9) (5.3, 11.7, 4.9) (7.9, 9.2, 5.9) (7.9, 11.7, 5.9)

Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 9.1 [900] 9.1 [900] 9.1 [900] 11.2 [900] 11.2 [900]

LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 3) (4.4, 4.7, 4.0) (4.4, 6.1, 4.0) (4.4, 8.9, 4.0) – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 3) 8.5 [900] 8.5 [900] 8.5 [900] – –
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 3)
(5.9, 6.3, 5.3) (5.9, 8.1, 5.3) (5.9, 11.8, 5.3) – –
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 3) 9.2 [900] 9.2 [900] 9.2 [900] – –
R 1.7 1.7 1.7 1.9 1.9

MPE(THP)/MPT(t) 1) 3.1/45 3.1/45 3.1/45 3.5/45 3.5/45

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (4.0, 4.0, 3.0) (4.0, 5.0, 3.0) (4.0, 7.0, 3.0) – –
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 11.2 [900] 11.2 [900] 11.2 [900] – –
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (6.3, 6.9, 4.9) (6.3, 9.2, 4.9) 6.3, 12.7,4.9) – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 12.4 [900] 12.4 [900] 12.4 [900] – –
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) SF 3)
– – – – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 3) – – – – –
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) SF 3)
– – – – –
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 3)
– – – – –
R 1.9 1.9 1.9 – –
MPE(THP)/MPT(t) 1) 4.0/45 4.0/45 4.0/45 – –

Chrome Performance Level Blue Performance Level Green Performance Level

Accuracy performance specifications according to ASME B89.4.1 b-2001:


- Linear displacement accuracy in X, Y, and Z (µm): LDA
- Volumetric accuracy performance (µm), where L is ball bar length in mm: Av [L]
- Repeatability (µm)
Max. Permissible Error MPE (µm) and Max. Permissible Time MPT (s) according to ISO 10360-4: 2000:
- Single stylus form error, scanning: MPE(THP)/MPT(t)
- Single stylus form error, scanning - Non-predefined path: MPE(THN)/MPT(τ)
ISO 12181-1: 2011 (VDI/VDE 2617 part 2.2): Form measurement error (µm): RONt (MZCI)
Probe Configuration:
• HP-S-X5/X3: stylus length 60 mm (2.36 in), tip diameter 5 mm (.20 in)
•HP-S-X1/X1C: stylus length 50 mm (2 in), tip diameter 5 mm (.20 in)
1)
MPE(THP/THN) and MPT(t): test sphere placed in the center of measuring volume
2)
RONt test on Ø 50 mm (2 in) ring gauge. Ring axis parallel to machine vertical axis, gauge placed in the center of measuring volume
3)
For Shop Floor packages only

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 13


GLOBAL S: ASME B89 SPECIFICATIONS - 05.YY.05 - 09.YY.08

Articulating head with HP-THD / TP200 05.YY.05 07.10.07 09.12.08 09.15.08 09.20.08
high precision trigger probe

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) – (3.0, 3.0, 2.5) (3.0, 3.0, 2.5) (3.5, 3.5, 3.0) (3.5, 3.5, 3.0)
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) – 6.0 [550] 6.4 [750] 6.4 [750] 6.4 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) – (4.3, 4.9, 3.8) (4.7, 5.3, 4.0) (5.2, 6.4, 4.0) (5.2, 7.3, 4.5)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) – 6.7 [550] 7.4 [750] 7.4 [750] 7.4 [750]
R 1.4 1.4 1.4 1.4

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (3.0, 3.0, 2.5) (3.0, 3.0, 2.5) (3.5, 3.5, 2.5) (3.5, 3.5, 3.0) (3.5, 3.5, 3.0)
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 5.0 [400] 6.0 [550] 6.4 [750] 6.4 [750] 6.4 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (4.0, 4.3, 3.5) (4.3, 4.9, 3.8) (4.7, 5.3, 4.0) (5.2, 6.4, 4.5) (5.2, 7.3, 4.5)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 5.5 [400] 6.7 [550] 7.4 [750] 7.4 [750] 7.4 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 1) – (3.7, 4.0, 3.2) (4.1, 4.4, 3.3) (4.4, 5.0, 3.5) (4.4, 5.4, 3.8)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 1) – 6.4 [550] 6.9 [750] 6.9 [750] 6.9 [750]
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 1)
– (4.6, 5.0, 4.0) (5.4, 5.7, 4.2) (5.7, 6.4, 4.6) (5.7, 7.0, 4.9)
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 1)
– 6.8 [550] 7.5 [750] 7.5 [750] 7.5 [750]
R 1.4 1.4 1.4 1.4 1.4

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (4.0, 4.0, 3.0) (4.0, 4.0, 3.0) (4.0, 4.0, 3.0) (4.0, 4.5, 3.0) (4.0, 4.5, 3.0)
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 7.0 [400] 8.0 [550] 9.0 [750] 9.0 [750] 9.0 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (5.0, 5.3, 4.0) (5.3, 5.9, 4.3) (5.7, 6.3, 4.5) (5.7, 7.4, 4.5) (5.7, 8.3, 4.5)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 7.5 [400] 8.7 [550] 10.0 [750] 10.0 [750] 10.0 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 1)
– (4.0, 4.0, 3.0) – – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 1)
– 8.4 [550] – – –
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 1)
– (5.1, 5.1, 3.8) – – –
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 1) – 8.8 [550] – – –
R 1.7 1.7 1.7 1.7 1.7

Chrome Performance Level Blue Performance Level Green Performance Level

Accuracy performance specifications according to ASME B89.4.1 b-2001:


- Linear displacement accuracy in X, Y, and Z (µm): LDA
- Volumetric accuracy performance (µm), where L is ball bar length in mm: Av [L]
- Repeatability (µm)
Probe Configuration:
• HP-THD: Standard force module, stylus length 10 mm (.39 in), tip diameter 4 mm (.16 in)
• TP200: Standard force module, stylus length 10 mm (.39 in), tip diameter 4 mm (.16 in)
1)
For Shop Floor packages only.

14 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com


GLOBAL S: ASME B89 SPECIFICATIONS - 12.YY.10 - 15.YY.10

Articulating head with HP-THD / TP200 12.15.10 12.22.10 12.30.10 15.22.10 15.30.10
high precision trigger probe

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (3.0, 3.0, 3.0) (3.0, 4.0, 3.0) (3.0, 6.0, 3.0) (5.0, 5.0, 4.0) (5.0, 6.0, 4.0)
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 7.9 [900] 7.9 [900] 7.9 [900] 10.0 [900] 10.0 [900]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (5.3, 5.9, 4.9) (5.3, 8.2, 4.9) (5.3, 11.7, 4.9) (7.9, 9.2, 5.9) (7.9, 11.7, 5.9)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 9.1 [900] 9.1 [900] 9.1 [900] 11.2 [900] 11.2 [900]
R 1.7 1.7 1.7 1.9 1.9

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (3.5, 3.5, 3.0) (3.5, 4.0, 3.0) (3.5, 6.0, 3.0) (5.0, 5.0, 4.0) (5.0, 6.0, 4.0)
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 7.9 [900] 7.9 [900] 7.9 [900] 10.0 [900] 10.0 [900]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (5.3, 5.9, 4.9) (5.3, 8.2, 4.9) (5.3, 11.7, 4.9) (7.9, 9.2, 5.9) (7.9, 11.7, 5.9)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 9.1 [900] 9.1 [900] 9.1 [900] 11.2 [900] 11.2 [900]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 1) (4.4, 4.7, 4.0) (4.4, 6.1, 4.0) (4.4, 8.9, 4.0) – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 1) 8.5 [900] 8.5 [900] 8.5 [900] – –
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 1)
(5.9, 6.3, 5.3) (5.9, 8.1, 5.3) (5.9, 11.8, 5.3) – –
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 1)
9.2 [900] 9.2 [900] 9.2 [900] – –
R 1.7 1.7 1.7 1.9 1.9

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (4.0, 4.0, 3.0) (4.0, 5.0, 3.0) (4.0, 7.0, 3.0) – –
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 11.2 [900] 11.2 [900] 11.2 [900] – –
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (6.3, 6.9, 4.9) (6.3, 9.2, 4.9) (6.3, 12.7, 4.9) – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 12.4 [900] 12.4 [900] 12.4 [900] – –
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 1)
– – – – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 1)
– – – – –
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 1)
– – – – –
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 1) – – – – –
R 1.9 1.9 1.9 – –

Chrome Performance Level Blue Performance Level Green Performance Level

Accuracy performance specifications according to ASME B89.4.1 b-2001:


- Linear displacement accuracy in X, Y, and Z (µm): LDA
- Volumetric accuracy performance (µm), where L is ball bar length in mm: Av [L]
- Repeatability (µm)
Probe Configuration:
• HP-THD: Standard force module, stylus length 10 mm (.39 in), tip diameter 4 mm (.16 in)
• TP200: Standard force module, stylus length 10 mm (.39 in), tip diameter 4 mm (.16 in)
1)
For Shop Floor packages only.

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 15


GLOBAL S: ASME B89 SPECIFICATIONS - 05.YY.05 - 09.YY.08

Articulating head with HP-TM trigger probe 05.YY.05 07.10.07 09.12.08 09.15.08 09.20.08

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (3.0, 3.0, 2.5) (3.0, 3.0, 2.5) (3.5, 3.5, 2.5) (3.5, 3.5, 3.0) (3.5, 3.5, 3.0)
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 5.0 [400] 6.0 [550] 6.4 [750] 6.4 [750] 6.4 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (4.0, 4.3, 3.5) (4.3, 4.9, 3.8) (4.7, 5.3, 4.0) (5.2, 6.4, 4.5) (5.2, 7.3, 4.5)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 5.5 [400] 6.7 [550] 7.4 [750] 7.4 [750] 7.4 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 1)
– (3.7, 4.0, 3.2) (4.1, 4.4, 3.3) (4.4, 5.0, 3.5) (4.4, 5.4, 3.8)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 1)
– 6.4 [550] 6.9 [750} 6.9 [750] 6.9 [750]
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 1) – (4.6, 5.0, 4.0) (5.4, 5.7, 4.2) (5.7, 6.4, 4.6) (5.7, 7.0, 4.9)
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 1) – 6.8 [550] 7.5 [750] 7.5 [750] 7.5 [750]
R 1.7 1.7 1.7 1.7 1.7

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (4.0, 4.0, 3.0) (4.0, 4.0, 3.0) (4.0, 4.0, 3.0) (4.0, 4.5, 3.0) (4.0, 4.5, 3.0)
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 7.0 [400] 8.0 [550] 9.0 [750] 9.0 [750] 9.0 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (5.0, 5.3, 4.0) (5.3, 5.9, 4.3) (5.7, 6.3, 4.5) (5.7, 7.4, 4.5) (5.7, 8.3, 4.5)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 7.5 [400] 8.7 [550] 10.0 [750] 10.0 [750] 10.0 [750]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 1)
– (4.0, 4.0, 3.0) – – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 1) – 8.4 [550] – – –
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 1)
– (5.1, 5.1, 3.8) – – –
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 1)
– 8.8 [550] – – –
R 2.0 2.0 2.0 2.0 2.0

Chrome Performance Level Blue Performance Level Green Performance Level

Accuracy performance specifications according to ASME B89.4.1 b-2001:


- Linear displacement accuracy in X, Y, and Z (µm): LDA
- Volumetric accuracy performance (µm), where L is ball bar length in mm: Av [L]
- Repeatability (µm)
Probe Configuration:
• HP-TM: Standard Force Module, stylus length 10 mm (.39 in), tip diameter 4 mm (.16 in)
1)
For Shop Floor packages only.

16 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com


GLOBAL S: ASME B89 SPECIFICATIONS - 12.YY.10 - 15.YY.10

Articulating head with HP-TM trigger probe 12.15.10 12.22.10 12.30.10 15.22.10 15.30.10

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (3.5, 3.5, 3.0) (3.5, 4.0, 3.0) (3.5, 6.0, 3.0) (5.0, 5.0, 4.0) (5.0, 6.0, 4.0)
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 7.9 [900] 7.9 [900] 7.9 [900] 10.0 [900] 10.0 [900]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (5.3, 5.9, 4.9) (5.3, 8.2, 4.9) (5.3, 11.7, 4.9) (7.9, 9.2, 5.9) (7.9, 11.7, 5.9)
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 9.1 [900] 9.1 [900] 9.1 [900] 11.2 [900] 11.2 [900]
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 1)
(4.4, 4.7, 4.0) (4.4, 6.1, 4.0) (4.4, 8.9, 4.0) – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 1)
8.5 [900] 8.5 [900] 8.5 [900] – –
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 1) (5.9, 6.3, 5.3) (5.9, 8.1, 5.3) (5.9, 11.8, 5.3) – –
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 1) 9.2 [900] 9.2 [900] 9.2 [900] – –
R 2.0 2.0 2.0 2.2 2.2

LDA (x,y,z) - (18 °C - 22 °C / 64 °F - 71 °F) (4.0, 4.0, 3.0) (4.0, 5.0, 3.0) (4.0, 7.0, 3.0) – –
Av, [L] - (18 °C - 22 °C / 64 °F - 71 °F) 11.2 [900] 11.2 [900] 11.2 [900] – –
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) (6.3, 6.9, 4.9) (6.3, 9.2, 4.9) (6.3, 12.7, 4.9) – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 12.4 [900] 12.4 [900] 12.4 [900] – –
LDA (x,y,z) - (16 °C - 26 °C / 61 °F - 79 °F) 1)
– – – – –
Av, [L] - (16 °C - 26 °C / 61 °F - 79 °F) 1) – – – – –
LDA (x,y,z) - (15 °C - 30 °C / 59 °F - 86 °F) 1) – – – – –
Av, [L] - (15 °C - 30 °C / 59 °F - 86 °F) 1)
– – – – –
R 2.2 2.2 2.2 – –

Chrome Performance Level Blue Performance Level Green Performance Level

Accuracy performance specifications according to ASME B89.4.1 b-2001:


- Linear displacement accuracy in X, Y, and Z (µm): LDA
- Volumetric accuracy performance (µm), where L is ball bar length in mm: Av [L]
- Repeatability (µm)
Probe Configuration:
• HP-TM: Standard Force Module, stylus length 10 mm (.39 in), tip diameter 4 mm (.16 in)
1)
For Shop Floor packages only.

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 17


GLOBAL S: NON CONTACT SENSORS SPECIFICATIONS

HH-A/HP-L-5.8 1) HH-A/HP-L-10.6 2) HH-A/HP-L-20.8 2) HH-A/HP-C-Ve 5)

3)
Probing Form Error 22 µm 22 µm 25 µm –
Point Spacing 53 µm 30 - 60 µm 13 - 50 µm –
Lines per second (max.) 40 Hz 53 Hz 100 Hz –
4)
PF2D,MPE – – – 10 μm
4)
PFD2D,MPE – – – 6 μm
4)
EUV,MPE – – – 4 + 2L μm

Chrome Performance Level Blue Performance Level Green Performance Level


1)
Some restrictions to workpiece size and machine configuration may apply when used on GLOBAL S 05.YY.05
2)
From GLOBAL S 07.YY.07. Some restrictions to workpiece size and machine configuration may apply when used on GLOBAL S 07.YY.07
3)
Maximum Permissible Probing Form Error PForm.Sph.1x25:Tr:ODS,MPE according to ISO10360-8:2013. Values are including expanded measurement uncertainty according
ISO/TS 17865:2016. Measured using a manufacturer supplied sphere- and plane artefact, each calibrated by an independent accredited lab.
4)
According to ISO10360-7:2011
5)
Not available on GLOBAL S Chrome

GLOBAL S: THROUGHPUT AND DYNAMICS

Max. probing frequency Max. 3D Speed Max. 3D Acceleration


(with scanning probes) mm/s (in/s) mm/s2 (in/s2)

High Dynamics 5) 1000 point/s 860 (33.86) 4300 (169.29)

GLOBAL S 15.YY.10 1000 point/s 860 (33.85) 2590 (101.96)

Standard Dynamics

GLOBAL S 05.YY.05 to 09.YY.08 1000 point/s 510 (20.08) 1700 (66.93)

GLOBAL S 12.YY.10 1000 point/s 430 (16.93) 1000 (39.37)

Chrome Performance Level Blue Performance Level Green Performance Level

5)
Dynamics reduction may apply to meet specific customer and/or local safety requirements

GLOBAL S: TEMPERATURE SPECIFICATIONS

Lab Extended Shop Floor


Temperature Temperature Temperature

18 °C ÷ 22 °C 16 °C ÷ 26 °C 15 °C ÷ 30 °C
Ambient temperature
(64 °F ÷ 71 °F) (61 °F ÷ 79 °F) (59 °F ÷ 86 °F)

1 °C/h - 5 °C/24h
1 °C/h - 2 °C/24h 1 °C/h - 5 °C/24h (1.8 °F/h - 9 °F/24h)
Max. air temperature variation
(1.8 °F/h - 3.6 °F/24h) (1.8 °F/h - 9 °F/24h) 2 °C/h - 10 °C/24h
(3.6 °F/h - 18 °F/24h) 6)
1 °C/m 1 °C/m 1 °C/m
Max. gradient in space
(1.8 °F/m) (1.8 °F/m) (1.8 °F/m)

6)
Accuracy specifications for this temperature range are available on request.

18 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com


PERFORMANCE VERIFICATION

MPE(E0) : maximum permissible MPL(R0): maximum permissible MPE(E150): maximum permissible


error of length measurement limit of the repeatability range error of length measurement

5 gauges have to be measured 3 times Extreme value of the repeatability 5 length gauges have to be measured
with one probing at each end, in 7 range of the length measurement 3 times in the YZ- or XZ plane with
different directions. All measuring error, calculated by three repeated opposite styli, mounted 150 mm off the
results must be within MPE(E0). measurements on each size for a total Z spindle axis. All measuring results
of 35 values. The 35 repeatability range must be within MPE(E150).
results must be within MPL(R0).

MPE(PFTU) : maximum permissible Maximum permissible scanning RONt (MZCI) maximum permissible
single stylus form error probing error form measurement error (2D)

A precision sphere has to be measured MPE(THP)/MPT(t) : A precision sphere A ring gauge is measured in scanning
with 25 probings. PFTU is the range of has to be scanned with 4 defined lines. mode, with high points density. The
all radii. THP is the range of all radii with the range of radial distances from two
The range of all radii must be within predefined path. concentric circles enclosing the
MPE(PFTU). MPE(THN)/MPT(t): A precision sphere roundness profile and having the least
has to be scanned with 4 defined lines. radial separation, is then evaluated.
THN is the range of all radii with the The range of radial distances must be
non-predefined path. within RONt.
The range of all radii and the scanning
time must be within MPE(THP/THN)
and MPT(t).

NOTE: ISO 10360-2 test with maximum part weight performed as an option upon request only.

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 19


PROBE HEADS AND SENSORS

Technical Characteristics HP-S-X1C HP-S-X3C HP-S-X5/X5 HD

Overtravel range ± 2 mm in all axes ± 1.25 mm in all axes ± 2 mm in all axes

Stylus joint M3 M5 M5

Max. stylus weight 33 g 150 g 500 g / 650 g

Vertical: up to 225 mm
Max. stylus length 360 mm 500 mm / 800 mm
Horizontal: up to 100 mm

HH-AS and HH-A-T5° HH-AS8 and HH-A-T2.5° HH-AS8-H2.5°


Technical Characteristics
Indexable Probe Head Indexable Probe Head Indexable Probe Head
A axis: +90° / -115° A axis: ±105° A axis: ±180°
Angular rotation
B axis: ±180° B axis: ±180° B axis: ±180°
Angular rotation step 5° 2.5° 2.5°

Max. applied torque 0.6 Nm 1.4 Nm 1.7 Nm

Max. extensions length 300 mm 450 mm 750 mm

Technical Characteristics HP-L-5.8 HP-L-10.6 HP-L-20.8

Laser Visible blue, class 2 Visible red, class 2 Visible red, class 2

Standoff and depth of FOV 140 ± 40 mm 170 ± 30 mm 180 ± 40 mm


24, 60, 124 mm 25, 51, 63, 130, 220 mm
Line-Width at mid-field of view 47 mm
user selectable user selectable
Ambient light immunity of the sensor 5 000 lx 40 000 lx 40 000 lx

Protection against dust and water All HP-L Sensors: IP64 (IEC 60529) (except for warm-up connection)

Sensor size L x W x H 116 x 62 x 86.5 mm 134 x 72 x 60 mm 137 x 76 x 85 mm

Technical Characteristics HP-C-VE

Nominal FOV size 6.5 mm x 5 mm

Nominal pixel size approx. 8.5 µm

Optical magnification x 0.73

Working distance 75 mm
2 rings, each with 4 sectors. 1 LED per sector on the inner ring, 2
Ring light configuration
LED per sector on the outer ring
Sensor size Ø x L max. Ø 75 mm x 137.5 mm (with TKJ mount)

20 HEXAGON MANUFACTURING INTELLIGENCE | HexagonMI.com


PROBE HEADS CONFIGURATIONS

05.YY.05 07.YY.07 09.YY.08 12.YY.10 15.YY.10

HP-S-X3C x ü • • •
HP-S-X5 x x ü ü •
HP-S-X5 HD x x • • ü
HH-A-T 5° • • x • •
HH-AS-T 5° ü • • • •
HH-A-T 2.5° • • • • •
HH-AS-T 2.5° x ü ü ü •
HH-AS-H 2.5° x x • • ü

HP-S-X1C • • • • •
HP-S-X3C ü ü • • •
HP-S-X5 x x ü ü ü
HP-S-X5 HD x x • • •
HH-A-T 5° • • x • •
HH-AS-T 5° ü • • • •
HH-A-T 2.5° • • • • •
HH-AS-T 2.5° x ü ü ü •
HH-AS-H 2.5° x x • • ü

HP-S-X1C • • • • x
HP-S-X3C ü ü ü ü x
HP-S-X5 x x x x x
HP-S-X5 HD x x x x x
HH-A-T 5° • • x • x
HH-AS-T 5° ü ü ü ü x
HH-A-T 2.5° • • • • x
HH-AS-T 2.5° x • • • x
HH-AS-H 2.5° x x • • x

Chrome Performance Level Blue Performance Level Green Performance Level

ü Recommended
• Available
x Unavailable

HexagonMI.com | HEXAGON MANUFACTURING INTELLIGENCE 21


Hexagon Manufacturing Intelligence helps industrial
COORDINATE MEASURING MACHINES
manufacturers develop the disruptive technologies of today
and the life-changing products of tomorrow. As a leading 3D LASER SCANNING

metrology and manufacturing solution specialist, our expertise


SENSORS
in sensing, thinking and acting – the collection, analysis and
active use of measurement data – gives our customers the PORTABLE MEASURING ARMS

confidence to increase production speed and accelerate


SERVICES
productivity while enhancing product quality.
LASER TRACKERS & STATIONS

Through a network of local service centres, production


MULTISENSOR & OPTICAL SYSTEMS
facilities and commercial operations across five continents,
we are shaping smart change in manufacturing to build a WHITE LIGHT SCANNERS

world where quality drives productivity. For more information, METROLOGY SOFTWARE SOLUTIONS
visit HexagonMI.com.
CAD / CAM

Hexagon Manufacturing Intelligence is part of Hexagon STATISTICAL PROCESS CONTROL


(Nasdaq Stockholm: HEXA B; hexagon.com), a leading
global provider of information technologies that drive AUTOMATED APPLICATIONS

quality and productivity across geospatial and industrial MICROMETERS, CALIPERS AND GAUGES
enterprise applications.
DESIGN AND COSTING SOFTWARE

© 2018-2019 Hexagon AB and / or its subsidiaries and affiliates. All rights reserved. This document is accurate as of its publication date.
Information is subject to change without notice.
Printed in USA, January 2019
Version 04
NA19004-01

You might also like