Professional Documents
Culture Documents
Specifications
Capacity & Resolution
Model* Capacity x Resolution (normal/enhanced) Overload† Construction
EDx–1T (EDx-2.5K ) 2,500 lbf x 2/0.5 1,000 kgf x 1/0.2 10,000 N x 10/2
Aircraft-quality
EDx–2T (EDx-5K) 5,000 lbf x 5/1 2,000 kgf x 2/0.5 20,000 N x 20/5 700%
2024 aluminum
EDx–5T (EDx-10K) 10,000 lbf x 10/2 5,000 kgf x 5/1 50,000 N x 50/10
EDx–10T (EDx-25K) 25,000 lbf x 20/5 10,000 kgf x 10/2 100,000 N x 100/20
Aircraft-quality
EDx–25T (EDx-55K) 55,000 lbf x 50/10 25,000 kgf x 20/5 250,000 N x 200/50 500%
E4340 alloy steel
EDx–50T (EDx-100K) 100,000 lbf x 100/20 50,000 kgf x 50/10 500,000 N x 500/100
EDx–75T (EDx-160K) 160,000 lbf x 100/50 75,000 kgf x 50/20 —
EDx–100T (EDx-220K) 220,000 lbf x 200/50 100,000 kgf x 100/20 — Aircraft-quality
400%
EDx-150T (EDx-330K) 330,000 lbf x 200/100 150,000 kgf x 100/50 — E4340 alloy steel
EDx-250T (EDx-550K) 550,000 lbf x 500/200 250,000 kgf x 200/50 —
†
* Model number in parenthesis shows U.S. convention for describing capacities. Ultimate overload protection rating.
Model A B C D E F G H J Shackle
EDx–1T 10.6 (269) 5.0 (127) 7.8 (198) 1.06 (26) 0.75 (19) 15.3 (389) 13.4 (340) 1.36 (34) 1.69 (43) Dillon
EDx–2T 10.6 (269) 5.0 (127) 7.8 (198) 1.06 (26) 0.75 (19) 15.3 (389) 13.4 (340) 1.36 (34) 1.69 (43) Dillon
EDx–5T 11.4 (289) 5.3 (135) 8.1 (206) 1.46 (37) 1.00 (25) 17.5 (444) 15.7 (400) 2.17 (55) 2.28 (58) Green Pin*
EDx–10T 11.5 (291) 5.3 (133) 7.9 (201) 2.01 (51) 1.38 (35) 21.0 (534) 18.5 (470) 3.50 (89) 3.25 (83) Green Pin*
EDx–25T 13.7 (348) 6.0 (152) 9.0 (229) 2.91 (74) 1.97 (50) 28.7 (730) 25.2 (640) 5.70 (146) 4.96 (126) Green Pin*
EDx–50T 15.8 (400) 6.8 (172) 10.3 (262) 4.13 (105) 2.75 (70) 38.8 (986) 33.7 (856) 8.98 (228) 7.09 (180) Green Pin*
EDx–75T 16.5 (419) 7.8 (197) 10.3 (262) 4.13 (105) 2.75 (70) 39.3 (998) 33.7 (856) 8.58 (218) 7.09 (180) Green Pin*
EDx–100T 18.0 (457) 7.8 (197) 11.0 (280) 5.00 (127) 3.25 (83) 46.9 (1191) 40.4 (1025) 11.14 (283) 7.48 (190) Green Pin*
EDx–150T 21.0 (533) 8.8 (222) 12.6 (321) 5.25 (133) 3.75 (95) 53.9 (1368) 45.6 (1159) 12.3 (313) 9.0 (229) Crosby
EDx–250T 27.0 (686) 9.8 (248) 17.5 (445) 8.5 (216) 5.00 (127) 75.8 (1925) 62.8 (1595) 17.9 (454) 13.0 (330) Crosby
* Dimensions using Green Pin shackles. Crosby shackles available. Consult factory for dimensions. Dimensions shown are nominal and subject to tolerances.
(SHACKLE OPENING)
Dynamometer Specifications Included with Remote: Carry case and batteries
Accessories: Rubberized case protector sleeve.
Remote wall mount bracket. Serial and remote cable assemblies.
Enclosure: Designed to NEMA4X/IP55. Suitable for continuous outdoor use.
Approval: CE
Accuracy: 0.1% of capacity up to EDx-50T.*
0.3% of capacity for EDx-75T and above.*
Repeatability: 0.1% of capacity up to EDx-50T.* Radio Specifications
0.3% of capacity for EDx-75T and above.*
* Normal resolution mode with Dillon provided shackles. FCC Certified: For unlicensed low power devices. No radio licensing or
Proof Load: 150% of capacity up to EDx-75T. permits required for normal operation.* (In the US and Canada.
110% of capcity Edx-100T and above. Check local ordinances in other countries.)
Ultimate Overload: See table on reverse. Frequency: ISM 2.4 GHz frequency band operates between 2.4 to 2.4835
GHz.
Safe Overload: 200% of capacity
Output Level: 10 mW (10 dBm)
Body Protection: Aluminum and alloy steel capacities are powder coated.
Display Update Rate: 1 time per second.
Bearings: Unmatched repeatability attained by needle bearings in
shackle pin holes up to EDx-5T. Shackle pin acts as inner race. Number of Links Remote Can Control: Up to 250 addresses.
Shackles: Forged industry standard anchor shackles. Models up to EDx-5T Configuration Address: Automatic and configurable.
use precision machined shackle pin. Higher capacities use bar stock pin. Antenna: Integral antenna.
Display: 128 x 64 dot-graphic LCD display shows up to 6 digits 1.0” (26 mm) Range: Open-air range up to 600 feet, line-of-sight. Indoor range
high plus annunciators and softkeys. Digits are .11 inches (3 mm) thick dependent upon environment with 300 feet common. Low power
for unmatched readability. radio systems are dependent upon interference levels from other
Display Update Rate: 2 times per second. radio systems and environmental conditions. Radio devices are not
suitable for all applications.
Peak Capture Rate: 10/100/1,000 Hz
Connector: Recessed sealed connector may be used for serial
communications or connection to a Communicator II remote. Weights
RS-232 Communication: Print or extract data easily. Continuous output
can drive a scoreboard. Configurable poll character. Weight
Calibration: Traceable to the National Institute of Standards and Unit with Unit Unit/Shackle
Technology. Certificate included with curve of readings. Passes only Weight Shackles Ship Weight Ship Dimension
Model lb (kg) lb (kg) lb (kg) in (mm)
with three consecutive confirming runs, with all points in specification.
Communicator 1.25 — 5 13 x 9 x 19
Battery Life: Stand alone EDXtreme with no radio and no backlight lasts
(.6) (2) (330 x 229 x 483)
up to 400+ hours. 150 hours continuous with Radio Link System. Use
with two C-Cell alkaline batteries. (When using backlight, battery life EDx–1T 4.3 8.6 18 16 x 7 x 19
will be reduced, depending on intensity.) (2.0) (3.9) (8) (406 x 178 x 483)
Specifications 16 x 7 x 19
(406 x 178 x 483)
15 x 8 x 26
(381 x 203 x 660)
EDx–50T 38 216 52 250
Enclosure: Designed to NEMA 3 / IP54 with optional sleeve. (17) (98) (24) (113)
Suitable for protected outdoor use. 16 x 7 x 19 17 x 9 x 23
Instrument Size: 9.5 x 5.0 x 2.5 inch (241 x 127 x 64 mm). (406 x 178 x 483) (432 x 229 x 483)
Accuracy: Not applicable. Only sends and receives digital information. EDx–75T 54 229 82 250
(25) (104) (37) (113)
Display: 128 x 64 dot-graphic LCD display can show full readings up to
5 instruments. 12 x 10 x 32 17 x 9 x 23
(305 x 254 x 813) (432 x 229 x 483)
Battery Life: Up to 80 hours continuous radio using (4) AA alkaline
EDx–100T* 70 395 480
batteries. (32) (179) (218)
Operating Temperature: -4° F to 158° F (-20° to 70° C) EDx–150T* 120 650 750
Connectors: Sealed connectors may be used for serial communications (54) (295) (340)
and wired connection to an EDXtreme dynamometer. EDx–250T* 250 1,490 1600
RS-232 Communication: Print or extract data easily. Continuous output (113) (675) (726)
can drive a scoreboard. Configurable poll character. *Ships on pallet