You are on page 1of 18
Implant Report vate of bith 01/01/2000 Project: scanmarkers Patient Information Name’ medvedeva nina verh Date of birth: 01/01/2000 Clinician: Drug therapi General health status: Exam Information Exam Date’ Image 400 Slice thickness: 0.2 Oo Description: Frontal view Project name: scanmarkers Last modified: Planning Information implants type Number of implants: Immediate loading: Mucosa soft ts Type of guide’ Fixation pins Type of fixation: Yes Flapless surgery: No S Rane reneneratinn Na s|GUIDE ee eee FEN SYSTEN Ree Page 1/18 Planning scheme: Implants Patient: medvedeva nina verh Date of birth: 01/01/2000 Project: scanmarkers |Notes: Postion Manufectrer_ Model sue Aoimert Abutmentsze Steve Colson warnings aaenismm Regular Straight lemme RealUi 2 CortexDentsl DYNAMIKConis! SEATS" ult unt 3 cap 2018 IMPR-5300]_ [30M604CAD1-10] aes Reguler Angulted Jierne_RealGUI “ Cortecdentsl DYNAMIXConics 382 "8m™ unum “""Gepiata” CAD 20 IMPR-5218] [30M604CAD1-10)| 4x20mm —__Joevolaion 90,H35mM™ sognepeee_unac_Necolson ® JDertalcare JoPteygo «XO DEVouton | SU HAS mmM sSiGNEDH_UNAS ST Regular Straight 2iermpe_ Real 2 CortecDental OYNAMIKconiel 3347S lune 3 cab 2015 (wPRS300) [SOMéOACAD'-1) RealGUIDE SALOFENS STEM Page 2/18 Patient: medvedeva nina verh Date of birth: 01/01/2000 Project: scanmarkers Position Manufacturer Model sve ‘Abutment Abutment size Sleeve _Colision warnings OeteD Regular Angulted 2ierime_Rea ey Cortex Dental DYNAMIXConical fE'3™™ ut Unit Degia #2 ‘CAD 201 IMPR-5218) _[SDMé04CAD1-19] 4x20mm ——JDEvolution 17", H3.5 mm. ‘No collision Ey Dentalcare —_JDPteryg0 Prt coeceyaiton . TEYLSSmIP ssicneDee._uNnac, ARealGUIDE SS A, a feacu SxSTeM : Page 3/18 Patient: medvedeva nina verh Date of birth: 01/01/2000 Project: scanmarkers Planning scheme: Implants Implant number: 12 Implant number: 18 Manufacturer: JDentalCare Manufacturer: Cortex Dental Mod Model: DYNAMIX Conical JoPterygo ize. 4x 20mm. Size: 3.3x11.5mm Abutment: JDEvolution Conical Abutment Abutment: Multi Unit Implant number: 14 implant number: 22 Manufacturer: Cortex Dental Model: DYNAMIX Conical Model: DYNAMIX Conical 3.8x13mm Si 1.5mm. Abutment: Multi Unit ‘Abutment: Multi Unit s|GUIDE ee eee FEN SYSTEN Ree Page 4/18 Patient: medvedeva nina verh Date of birth: 01/01/2000 Project: scanmarkers Planning scheme: Implants Implant number: 24 Manufacturer: Co tex Model: DYNAMIX Conical Size: 3.8x13 mm Abutment: Multi Unit Implant number: 28 Manufacturer: JDentalCare Model: JDPterygo Size: 4 x20 mm Abutment: JDEvolution Conical Abutment Page 5/18 Patient: medvedeva nina verh Date of birth: 01/01/2000 Project: scanmarkers Planning scheme: Implants Implant number: 12 Implant number 18 Implant number 14 Implant number: 22 eae ae ae me Page 6/18 Patient: medvedeva nina verh Date of birth: 01/01/2000 Project: scanmarkers Planning scheme: Implants Implant number: 24 Implant number: 28 Page 7/18 Patient: medvedeva nina verh Date of birth: 01/01/2000 Project: scanmarkers Planning scheme: Pins Pin name’ Pin 7 Pinrname: Pin Pin name: Pin 5 Pin name: Pin 1 Page 8/18 Patient: medvedeva nina verh Date of birth: 01/01/2000 Project: scanmarkers Planning scheme: Pins Pin name: Pin2 Pinrname: Pin 6 Page 9/18 Patient: medvedeva nina verh 1 2 Date of birth: 01/01/2000 Project: scanmarkers Position Manufacturer Mode! sve Abutment Abutment size—=««Skeeve—_‘Sleeve top height aax1smm Regular Straight >lemme_RealGUIC 2 Cortex Dental DYNAMIKConial SRNLETIM Mut Unit 1 ‘CAD 2015, 900mm [MPR5200) [20M60ACADI-10] Bone density inside the implant ume Notes: > Anatomy collision Security zone collision Page 10/18 Date of birth: 01/01/2000 Project: scanmarkers 1 4 Patient: medvedeva nina verh Position Manufacturer Model size Abutment Abutment size Sleeve Sleeve top height aa Regular Angulated Dierme_RealGUIC 4 Cortex Dental DYNAMIX Conical Mutt Unit Degia 2 ‘CAD 2015, 9.00 mm Ico-1336), IMPR-SZ18]_[9DMé04CAD1-10) Bone sityinsdetheimplant volume Njoteg: > Anatomy collision Security zone collision Page 11/18 Patient: medvedeva nina verh 1 8 Date of birth: 01/01/2000 Project: scanmarkers Position Manufacturer Mode! sve Abutment Abutment size—=««Skeeve—_‘Sleeve top height 4x20mm JOE volution 30", H35mM ssignepeee_UNAS 18 WWentalcere JDPterygo «AZO DEvollon, | SU HSS SIGNED! UNAS 001 mm Bone density inside the implant volume Notes: Page 12/18 Patient: medvedeva nina verh 22 Date of birth: 01/01/2000 Project: scanmarkers Position Manufacturer Mode! sve Abutment Abutment size—=««Skeeve—_‘Sleeve top height aax1smm Regular Straight >lemme_RealGUIC 2 Cortex Dental DYNAMIKConial SRNLETIM Mut Unit 1 ‘CAD 2015, 900mm [MPR5200) [20M60ACADI-10] Bone density inside the implant ume Notes: > Anatomy collision Page 13/1 Patient: medvedeva nina verh 24 Date of bith 01/01/2000 Project: scanmarkers ell ace Notes: EE wr’ Security zone collision Page 14/18 Patient: medvedeva nina verh 28 Date of birth: 01/01/2000 Project: scanmarkers Position Manufacturer Mode! sve Abutment Abutment size—=««Skeeve—_‘Sleeve top height 4x20mm JOE volution 17, H35mM ssignepeee_UNAS Ey WWentalcere —vDPterygo «AZO DEvoltion, | TZLHSE MM SIGNED! UNAS 001 mm Bone density inside the implant Notes: Page 15/18 Pins Position Manufacturer Model Se Sleeve oM_ReslGUit Pin? SDlemme 1.520mm 1.520 mm Rea Position Manufacturer Model» Ste—=‘Skeeve OM_Reslouit PinS aDlemme 1.5x20mm 1.5x 20mm M—Rea Position Manufacturer Model Se =‘ Skeeve M_RealGult Pind aDlemme 1.5x20mm 1.x 20mm M—Resl Patient medvedeva ni verh Date of birth: 01/01/2000 Project: scanmarkers Page 16/18 Pins Position Manufacturer Model Se Sleeve oM_ReslGUit Pint 8Dlemme 1.520mm 1.520. mm ™Rea ston Manufacturer Model «Sze. Sleeve OM_Reslouit Pin2 aDlemme 1.5x20mm 1.5x 20mm ’M—Rea Position Manufacturer Model Se =‘ Skeeve M_RealGult Pind aDlemme 1.5x20mm 1.5% 20mm M—Resl Patient, medvedeva ni verh Date of birth: 01/01/2000 Project: scanmarkers Page 17/18 Patient: medvedeva nina verh Pins Date of birth: 01/01/2000 Project: scanmarkers Position Manufacturer Model Se Sleeve oM_ReslGUit Piné 3Dlemme 1.5x20mm 1.5x 20mm M—Real x ie Page 18/18

You might also like