How To Size A Pump
How To Size A Pump
This is the case for all types of pumps: centrifugal or positive displacement.
Other key considerations for pump sizing are the net positive suction head available (NPSHa)
and the power required to drive the pump.
Flow Rate
Usually, the flow rate of liquid a pump needs to deliver is determined by the process in which
the pump is installed. This ultimately is defined by the mass and energy balance of the
process.
For instance the required flow rate of a pump feeding oil into a refinery distillation column
will be determined by how much product the column is required to produce. Another
example is the flow rate of a cooling water pump circulating water through a heat exchanger
is defined by the amount of heat transfer required.
The static head difference across the pump is the difference in head between the discharge
static head and the suction static head.
The discharge static head is sum of the gas pressure at the surface of the liquid in the
discharge vessel (expressed as head rather than pressure) and the difference in elevation
between the outlet of the discharge pipe, and the centre line of the pump.
Discharge static head = Discharge vessel gas pressure head + elevation of discharge pipe
outlet – elevation of pump centre line
The discharge pipe outlet may be above the surface of the liquid in the discharge vessel or it
may be submerged as shown in these 3 diagrams.
The suction static head is sum of the gas pressure at the surface of the liquid in the suction
vessel (expressed as head rather than pressure) and the difference in elevation between the
surface of the liquid in the suction vessel and the centre line of the pump.
Suction static head = Suction vessel gas pressure head + elevation of suction vessel
liquid surface – elevation of pump centre line
The total frictional head losses in a system are comprised of the frictional losses in the
suction piping system and the frictional losses in the discharge piping system.
Frictional head losses = frictional losses in suction piping system + frictional losses in
discharge piping system
The frictional losses in the suction and discharge piping systems are the sum of the frictional
losses due to the liquid flowing through the pipes, fittings and equipment. The frictional head
losses are usually calculated from the Darcy-Weisbach equation using friction factors and
fittings factors to calculate the pressure loss in pipes and fittings.
Darcy-Weisbach equation:
In order to calculate the frictional head losses you therefore need to know the lengths and
diameters of the piping in the system and the number and type of fittings such as bends,
valves and other equipment.
It is important because for the pump to operate properly, the pressure at the pump suction
must exceed the vapour pressure for the pumped fluid to remain liquid in the pump. If the
vapour pressure exceeds the pressure at the pump suction, vapour bubbles will form in the
liquid. This is known as cavitation and leads to a loss of pump efficiency and can result in
significant pump damage.
To ensure that the pump operates correctly the net positive suction head available (NPSHa)
must exceed the net positive suction head required (NPSHr) for that particular pump. The
NPSHr is given by the pump manufacturer and is often shown on the pump curve.
Net positive suction head available = absolute pressure head at the pump suction –
liquid vapour pressure head
Pump Power
Pumps are usually driven by electric motors, diesel engines or steam turbines. Determining
the power required is essential to sizing the pump driver.
Pump power = flow rate x total differential head x liquid density x acceleration due to
gravity ÷ pump efficiency
30000 kg/hr of water needs to be pumped from one vessel to another through the system
shown in the diagram below. The water is at 20C, has a density of 998 kg/m3 , a vapour
pressure of 0.023 bara and a viscosity of 1cP. We’ll assume that the pump efficiency is 70%.
Calculation