-The performance and life of ACT shutter (*1) unit are not guaranteed for all card fishing fraud (*2).
-The performance and life of ACT shutter unit are not guaranteed when the other media such as non-ISO/IEC 7810
standard card, metal plate and so on are inserted.
*1:See section 0. 7 Shutter unit (page.4) for more information about ACT shutter.
*2:Regarding the applicable module for ACT, see Applicable Card Reader / Writer.
Table of Contents
I. Introduction I
II. Applicable Card Reader / Writer I
III. Reference Standards II
IV. Notice for IC card (ICC) II
1 General Specifications 1
2 Applicable IC card specifications 1
3 Applicable SAM chip 2
4 Applicable magnetic card 3
5 Applicable contactless card 3
6 CIM/MM unit 3
7 Shutter unit 4
8 Recovery process of "Power Shutdown" 4
9 Required power supply 5
10 Environmental conditions 5
11 EMI/EMS 5
12 General performance 6
13 Life and Reliability 6
14 Electronic interface 7
15 Software interface 8
16 Response to Regulated Chemical Substances 8
17 Correct usage for safety 8
18 Hardware Overview 9
19 Circuit block diagram 13
20 Appendix A 15
21 Appendix B 16
22 Appendix C 18
Notice
In case of fixing a screw on the bottom mounting bracket at the shutter solenoid for installing type1 V2XF
to the ATM plate, please notice that the length of screw striking into V2X from the outer surface does not
exceed 4 mm.
[7] Card position detection Photo sensor at 4 places. The state of all sensors can be retrieved by
a command from the Host.
[8] Retrieval A card can be retrieved by a command from the host when the card is
not pulled out within an interval time.
[9] Reject Box
(1)Installation The reject box can be mounted at the rear of V2X
The reject box is prepared by our customers.
(2)Rejected cards number Can be reported by a command from the Host.
Notice
The positioning sensor might be interfered by the light, which enters through the inlet if V2X is installed
with the inlet faced to the direction of the object, which emits the light. The luminous intensity at which the
light is thrown directly through the inlet should be at the inlet position within 10000 luxes.
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2(1/20)
(2) Synchronous card
1) Support IC cards In conformity to ISO7816-1/2/10, SLE4418/4428/4432/4442,
and AT24C01ASC/AT24C02SC/AT24C16SC/AT24C64SC
2) Vcc 5V
3) Vpp Not connected
*1 Answer To Reset
*2 Communication speed can be changed by PPS procedure.
[3] IC card Handling
(1) The contact mechanism is pulled down and IC contacts station is pushed down onto IC card when a
card is transported to the proper position.
(2) The state of the IC contact echo sensor can be checked by a command from the Host.
(3) The resistance between IC contact on card and one on Card Reader / Writer is 500 milliohm or less.
When it is hard to attach or detach a chip, it is recommendable the upper plate is detach.
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2(2/20)
4 Applicable magnetic card
[1] Magnetic card type In conformity to ISO/IEC 7811-1/2/6
[2] Magnetic card coercivity ISO/IEC 7811-2/6
LoCo Read/Write default supported
HiCo Read default supported
[3] Reading function Read specified tracks simultaneously.
[4] Magnetic recording method Two-Frequency Recording Method (F2F)
[5] Magnetic R/W head Structure: Single Gap Head
Material: Permeability alloy + Ceramic Block
Width of Tracks 3 mm (Writing)
1 mm (Reading)
[6] Recording
ISO Track 1 ISO Track 2 ISO Track 3
Density (bpi) 210 75 210
Capacity (char.) *1 Max. of 79 Max. of 40 Max. of 107
Length Variable Variable Variable
Character structure (bits/char.) 7 5 5
*1 Including SS, ES and LRC
6 CIM/MM unit
[1] Card transfer speed C/R can be worked at the transfer speed of 200 mm/s +/- 10%
[2] Optional Mounting parts Mounting Bracket and fixing screws for the optical sensor of CIM/MM is
provided as option. These parts can be purchased by customer's order.
See 0. 18 Hardware Overview and Upgrade Parts List.
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2(3/20)
7 Shutter unit
[1] Card detection function
(1) Card width detection switch (mechanical switch) is installed.
(2) Magnetic stripe detection head detects magnetic data on any track of three ISO tracks.
[2] Outer length of card
The card protrudes from 28mm to 34mm when the card is returned, and maximum 38mm when the card is
moved to rear side.
[3] Measures for antirust
The materials to withstand rust are used in shutter unit.
[4] Advanced Card Trap-proof function (ACT)
This function is supported only with -03* series (refer to the Applicable List of V2X).
Following shows main specifications (See Appendix C for detail). (*1)(*2)
(1) ACT shall work immediately by command from the host regardless of the card location. (*3)
(2) If the card is jammed in the designated zone, ACT shall work automatically without host command. (*4)
(3) Minimum force of card lock is 150N. (*5)
ACT can hold the card against 150N.
(4) Applicable card is the card conformed to ISO/IEC 7810/ID-1. (*6)
(5) ACT lock shall be released by hand (*7).
(6) The lock will not be released automatically even though the power is shutdown while the ACT is
working.
NOTE
*1. There is a possibility that noise of around 90 dB is made in case of activating ACT.
(The C/R with ACT is shipped from factory in condition that ACT is activated.)
*2. Please release the ACT lock at first according to the ACT notice included in the carton box, when
unpack and install the C/R.
*3. Under conditions of Setting 0 as shown in 2) ACT operation type setting in Appendix C, ACT does not
work. Please refer to Appendix C for details.
*4. Under conditions of Setting 2 as shown in 2) ACT operation type setting in Appendix C, ACT does not
work automatically. Please refer to Appendix C for details.
*5. There is a possibility of card being damaged by ACT on the surface of card.
*6. Applicable card shall conform to ISO/IEC 7810/ID-1 and ACT unit must be inspected and maintained
along the ACT maintenance manual (Doc.No. 2749006-3).
*7. Please refer to Appendix C for the way to release the lock.
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2(4/20)
9 Required power supply
[1] Power supply voltage 24V DC + 10% / – 15%
[2] Ripple of power supply 500mVp-p or less
[3] Power consumption
In operation 1.0A or less when motor starts to revolve
In standby 200mA or less
In peak to start motor/solenoid 1.8A for 150ms/2.0A for 15ms
10 Environmental conditions
[1] Temperature
(1) In operation 5 to 50 degree (Celsius)
(2) In storage -25 to 55 degree (Celsius)
[2] Humidity
(1) In operation 5 to 85% RH, no condensation and absolute air humidity of 23 g/m3 or less
(2) In storage 5 to 90% RH, no condensation and absolute air humidity of 40 g/m3 or less
[3] Dust accumulation Total mass of floating dusts, which sizes are less than 10
micrometers, is less than 0.15 mg/m3.
[4] Corrosive gasses Not allowed
[5] Lighting Lower than 1,000 lx, no direct sunlight
[6] Installation No direct ingress of rain, No leakage of electricity, No intrusion of insects
11 EMI/EMS
[1] EMI EN50081-1, IEC801-3/4/5/6
Confirmed EN55022 Class B
Confirmed FCC part15 Class A
[2] EMS EN50082-1, IEC801-2, EN55024
(1) Electrostatic discharge Confirmed EN61000-4-2
Immunity inlet +/- 6kV contact discharge +/-8kV air discharge
others +/- 4kV contact discharge +/-4kV air discharge
Destruction inlet +/- 8kV contact discharge +/-15kV air discharge
others +/- 6kV contact discharge +/-8kV air discharge
(2) Radio-frequency electromagnetic field Confirmed EN61000-4-3
(3) Electrical transient/burst Confirmed EN61000-4-4
(4) Surge Confirmed EN61000-4-5
(5) Conducted disturbances, induced by radio-frequency fields Confirmed EN61000-4-6
(6) Limits of terminal interference voltage Confirmed EN61000-4-8
[3] R&TTE Directive (Only with Contactless unit)
(1) Radio EN 300 330-1 EN 300 330-2
(2) EMS EN 301 489-1,EN 301 489-3
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2(5/20)
12 General performance
[1] Vibration resistance
Test at 10-55 Hz and a single vibration width of 0.05 mm
[2] Shock resistance
Test at a peak acceleration of 200 m/s2 three times in six directions (up & down, right & left and back &
forth) respectively
[3] Dielectric strength
250V DC for 1 minute
[4] Insulation resistance
10 M ohm or more at normal temperature and 250V DC
NOTE
*1. In case of cleaning, cleaning should be done based on Periodic Maintenance Manual.
*2. “1 pass” means 2-way card transport for forward and backward.
*3. This performance is limited in the occasion that the locked card is the one specified in ISO/IEC 7810
and card pulled force is less than 150N.
*4. Refer to ACT maintenance manual (Doc.No.2749006-3) for the way to check lock force and treat if the
lock force is less than 150N.
*5. Refer to ACT maintenance manual (Doc.No.2749006-3) for the way to check scratches, deformation,
and cracks on the component parts.
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2(6/20)
14 Electronic interface
[1] Electronic interface
(1) RS232
1) Transmission speed 9600,19200,38400 bps (Automatic Recognition)
2) Synchronous method Asynchronous
3) Communication method Half-duplex
[2] Signal explanation and pin layout
(1) RS232 interface connector
9 pin D-Sub socket, DELC-J9SAF-20L9(JAE, Japan) or equivalent is used in PCB.
( Cable with connector between Host and C/R isn't attached to C/R )
Counter Connector
(connector on the side of cable)
XGND
Resister for charge up
120ohm
X24V
ExternalCapacitor
External
NOTE
The length of the cable between the power supply and C/R should be less than 3m.
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2(7/20)
(3) I/O connector
Connector type JST S14B-PHDSS is used in PCB.
NOTE
(1) I/O
Output port Transistor open collectorIOL max 50 mA
VCEO max 24V
Input port TC74HC240AF or equivalent (10k ohm pulled up)
VIL max:0.5V, VIH min:2.4V
15 Software interface
[1] Transmission protocols V2X Series Card Reader / Writer Data Transmission Specification
for RS232
Document No. :
GB-H-01047 : For V2XF-11JL-001S, 002S, 001, 021S, 031, 031S,
V2XF-11JL-008S
MTA-H-04016 : For V2XF-11JL-AP1
[2] Port to host Handling with a magnetic card and an IC card via single port
[3] Format A common APDU format is used for handling various IC cards,
such as memory card
[4] Downloadable All software are supported to be downloaded..
[5] Module Firmware is independently divided into every functional module
(e.g. IC card handling module, SAM handling module, etc.) and every
module can be independently downloaded respectively
(regardless of order of download)
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2(8/20)
18 Hardware Overview
[1] Outline Dimensions for Height 95 mm [Type1]
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (9/20)
[2] Outline Dimensions for Height 90 mm [Type 2]
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (10/20)
[3] Outline Dimensions for Height 95 mm [Type1, 5 SAM Model]
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (11/20)
[4] Parts location
SAM
SW4 SL2
SW3 S1 S2 S3 S4
M1
SW1
Head
SW2 Antenna
SL1
Abbreviation Notes
S1-S4 Positioning sensor
SW1 Pre-head sensor
SW2 Card width sensor
SW3 Sensor to detect the open/close of shutter blade
SW4 Sensor to detect IC contact completely down
SL1 Solenoid which opens the shutter blade
SL2 Solenoid which pulls IC contact down
M1 Motor
Head Read/write magnetic head
SAM Position to install the PCB for SAM
Antenna Position to install the antenna for contactless card
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (12/20)
19 Circuit block diagram
[1] With Normal Shutter Unit
PCB
Shutter Unit
CPU
RAM 2Mbit Shutter Solenoid
(256kBytes) Circuit For Shutter Open
Shutter Closed
Flash 8Mbit
Detect Switch
(1Mbytes)
Card Insertion
Detect Switch
Host RS232
Terminal Driver/Receiver Mag Stripe
Detect Head
SAM Unit
SAM Socket
SAM Control
Circuit
Contactless
Control Circuit
Antenna
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (13/20)
[2] With ACT Shutter Unit
PCB
ACT Shutter Unit
CPU
RAM 2Mbit Shutter Solenoid
(256kBytes) Circuit For Shutter Open
Shutter Closed
Flash (8Mbit) Detect Switch
(1Mbytes) ACT
Card Insertion Circuit
Host RS232 Detect Switch Solenoid
Terminal Driver/Receiver
For ACT
Mag Stripe
Detect Head ACT Echo
Sensor
Regulator 1.6V A/D Converter
Mag Read LoCo Mag Head
Regulator 3.3V
Stripe Detect ISO1/2/3
Regulator 3V
LoCo Mag Write
DC/DC 5V
External PLL(75bpi)
Encoder
Capacitor Motor Drive
Motor
Circuit
Photo Power
IC Contact Unit
Changeable Circuit
Position IC Contact
Sensor Move Detection
Switch
Solenoid Driver Solenoid
IC/Memory Card Driver for ICC Contact
& T=0 ErrorDetection IC Contact
SAM Unit
SAM Socket
SAM Control
Circuit
Contactless
Control Circuit
Antenna
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (14/20)
20 Appendix A
Abstract from ISO 7816-2: 1999 (E)
Dimensions in millimeters
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (15/20)
21 Appendix B
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (16/20)
Table 2: Combination of F and D for SAM
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (17/20)
22 Appendix C
Additional information for ACT version
1) Overview and parts location of ACT version
[1] Overview of ACT version
[Type: V2XF-11JI-031]
[Type: V2XF-11JI-031S]
NO SCALE
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (18/20)
[2] ACT Unit parts location
SLA-1 L1
B2
SA-1
B1
B3
[1] Setting 0
It makes ACT operation “invalid” ----- ACT does not work even if the host commands to work.
[2] Setting 1
It makes ACT auto-operation “invalid” ---- ACT works only when the host commands to work.
Concerning how to release the ACT, describe later.
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (19/20)
2) How to release ACT
Following procedures as below unlock the lever. (*1)
[1] Push and rotate the LEVER 1 to the stitch-lined position.(arrow <1>)
[2] Push down the LEVER 2 to the position shown in the drawing .(arrow <2>) (*2)
[3] This shows released ACT. Make sure the positions of LEVER 1 and LEVER 2.
[4] Execute initial reset command of card reader.(*3)
[1] [2]
<1> <2>
[3]
[NOTE]
*1: In case that the lever 2 is hard to be pushed, push the locked card a little into the card reader so that
the lever can be moved easier.
*2: As the LEVER 2 is pushed down, LEVER 1 also moves automatically.
*3: The ACT operation counter is not reset by initial reset and power-off of the card reader.
Refer to V2X Series Card Handling Device Data Transmission Specification (Doc.No. GB-H-01047) to
reset the ACT operation counter.
© Hitachi-Omron Terminal Solutions, Corp. 2002-2009 All Rights Reserved. GB-B-01007 G2 (20/20)