Professional Documents
Culture Documents
Implant Solution
Help your daily practice superior
Ver.28
SINCE
1994
THE OLDEST
IMPLANT CASE IN KOREA
#35: BIOPLANT™, 1st generation of the COWELL® Implant, Korea’s first dental implant developed in 1994.
#25, 36 & 37: ATLAS Implant System™, 2nd generation of the COWELL® Implant, Korea’s first ASD treated Implant.
#32, 33 & 47: INNO Implant System™, 3rd generation of the COWELL® Implant, Nano/CaP soaking technology applied.
®
• Introduction
Process Flow Chart 008
COWELL® Warranty 010
Package System 011
SLA-SH® Surface Treatment 016
COWELL® CLASS 1000 021
®!" • Digital Guided Surgery Kit ®!
$
• COWELL® BMP Series 270
InnoFit® Lodestar Plus Kit 136 • INNO-CaP 278
InnoFit® Lodestar Kit 150 • INNO OSS™ Allo 280
• Digital Prosthesis • DiaBone 281
SFIT Ti-Base System • MEGA DERM™ Plus 282
· Sub. SFIT Ti-Base System 160 • Diaderm® M 284
· Sub. SFIT Absolute Ti-Base System 166 • BOSS® System 285
· Sub. Multi SFIT Ti-Base System 172 • InnoGenic™ Non-resorbable Membranes 288
· Int. SFIT Ti-Base System 180
1998 • Founded Asrahi Medical. 2011 • Obtained US patent for E.rhBMP-2 Coated Implant.
1999 • Established R&D corporation with PNU’s Oral and Biotechnology Research Center. 2012 • Obtained MFDS Approval for E.rhBMP-2 Spinal Fusion Clinical Test Plan and launched the INNO SLA Implant System™.
2000 • Converted to COWELLMEDI corporation (Cowellmedi Co., Ltd.) and obtained ISO9001 certificate. 2013 • Obtained US FDA approval for the INNO SLA Implant System™.
2003 • Obtained US-FDA approval for the BIOPLANT™ Implant System. 2015 • Applied SLA-SH® surface treatment on the INNO SLA Implant System™ ˧ INNO SLA-SH® Implant System.
(*SLA-SH® Surface Treatment : the world's first superhydrophilic surface made by dry process
2004 • Medaled for contribution of developing Korea's first dental implant, the BIOPLANT™, from Korea Government. using Nano/CaP soaking technology. For the details, refer to the pages 16 to 21).
2005 • Obtained GMP, ISO13485 certificate, US FDA approval for the ATLAS Implant System™ and CE (EC) certificate. 2016 • Established a subsidiary in China (COWELLMEDI China) and a training course, ACID(Advance Course in Implant Dentistry)
with MMS (Miami Medical Seminars).
2006 • Established subsidiaries in USA (COWELLMEDI USA) & Taiwan (COWELL Biotech) and 2017 • Developed Collagen based bone graft materials and launched Sonator™ 80’s System.
COWELLMEDI Tissue Engineering Institute for Growth Factors.
2007 • Obtained a patent for E.rhBMP-2 coated dental implant in Korea. 2018 • Launched the InnoGenic™ Wifi-Mesh and InnoGenic™ PTFE-Mesh.
REGENERATIVE SOLUTION
2008 • Established COWELL Training Center in L.A, USA. 2019 • Launched the InnoFit Lodestar Plus Kit, InnoGenic Autobone Harvester Kit, InnoGenic Bone Carrier.
COWELL®
2009 • Obtained MFDS approval for clinical test of E.rhBMP-2, the COWELL® BMP. 2020 • Launched the InnoGenic™ GBR Kit and Spread Fit™ SFIT Ti-Base System.
COWELLMEDI HISTORY
REID
Research and
REGENERATIVE SOLUTION
research for the benefits of patients.
dental professional across the globe.
COWELL®
006 REID REID 007
COWELLMEDI HISTORY
Process Flow Chart
CNC Machining Cleansing
REID
Precise machining process using state of the art computer numerical control system Cleansing process by ultrasonic wave using the 3rd stilled distilled, vacuum dry and heating dry sterilization enable
fused to the COWELL® Class 1000, operated by world-class technical unit. ultimately sterilized products and no residues are left on products.
COWELL®
008 Process Flow Chart Process Flow Chart 009
COWELLMEDI HISTORY
COWELL® Warranty Package System
* For more details, visit our website at www.cowellmedi.com
1. Color classification (Coding) by fixture type and external label marking
A. Color classification by fixture type
Submerged Submerged Internal External Submerged Mini Cement Mini Ball
Fixture type (Sub.) Short (Sub.) (Int.) (Ext.) Narrow (Sub-N.) (1P-C.) (1P-B.)
REID
The period Package
Implant Lifetime Replacement with equivalent Implant shall begin
from the sale date
5) In case the procedure is not performed in compliance with biological indication : PRODUCT NAME COWELL® INNO Implant System
CATALOG No. ST4010SM Submerged (Sub.) - - - - -
(E.g. distance between buccal wall and implant should be at least 2mm). SIZE Ø4.0X10mm(Sub.Hex.Taper)
6) In case the procedure is conducted using contaminated surgical devices. LOT NO. 20A060040A Submerged - - - - -
7) In case implants are transplanted onto patients who sustain or are infected with cell issue contamination. DATE OF 2020-01-06 Short (Sub.)
REGENERATIVE SOLUTION
Rx Only
MEDICAL DEVICE CWM-L-004 (Ver.3)
COWELL®
Ex.) INNO SLA-SH® Sub. Fixture (No-Mount)
Dimension : Ø4.0X10mm
1. Device Description status, and adequacy of bone. Lateral cephalometric radiographs, CT scans and
The COWELLMEDI implant system includes a variety of precision-machined tomograms may also be beneficial. Adequate radiographs, direct palpation and $PWFS4DSFX $PWFS4DSFX
fixtures manufactured from titanium. These implants are surgically inserted into a visual inspection of the fixture site are necessary prior to treatment, planning and
Middle Middle
mandible (the lower jawbone) or a maxillary bone (the upper jawbone) and serve as use of the COWELLMEDI fixtures.
a replacement for patient's tooth root providing a stable foundation for restoration.
7. Adverse Effects
2. Intended for use Some of the complications (loss of fixture anchorage, prosthesis etc.) are possible
To support dental prosthesis as a dental device, which is implanted into alveolar occurrences after surgery. Lack of quantity or poor quality of remaining bone, .PVOU'JYUVSF
bone to recover masticatory function and give better esthetics in patients with infections, poor patient oral hygiene or cooperation, patient discomfort, fixture 'JYUVSF
partially or full edentulous jaws. mobility, local soft tissue degeneration, and unfavorable fixture placement or
alignment are some potential causes for loss of anchorage.
No-Mount Pre-Mount
3. Directions for use
REID
1) Surgery - The first stage 8. Surgical complications
Lower Lower
a. According to the patient's condition, appropriate dental cleaning operations may The implant procedure has risk, including localized swelling, dehiscence,
be performed and preventive antibiotics may be administered prior to implant tenderness of short duration, edema, hematoma or bleeding. Numbness of the
operation. lower lip and chin region following lower jaw surgery, and of the tissue beside the
b. Clean and disinfect the operative site, administer local anesthesia in the area nose following upper jaw surgery, is a possible side-effect of the surgery. Though it
and expose the alveolar bone by making appropriate incisions and reflecting the would most probably be of a temporary nature, in very rare cases, the numbness
gingival tissues along the alveolar crest in the area from where teeth were has been permanent. Gingival-mucosal (gum tissue) ulceration, tissue reaction or
extracted. infection may occur, but generally responds to local care.
c. Drill into the gum in order to implant a fixture into the planned place with
various dental operation tools. The speed of revolution of the drill should be 9. How to manage after implanting the Product
adjusted by the condition of the bone and the kinds of operation tools. Saline a. The upper jaw requires a healing period of 6~8 months depending on the bone
solution should be poured onto the area so that necrosis doesn't occur by heating quality and the lower jaw requires a healing period of 3~5 months depending on Taking out the ampule
of the bone (The speed for all drilling should be less than 1,200 rpm). the bone quality. If pressures such as mastication would be applied to the fixture
1 2
driver to connect to the Cover Screw with torque 5 N.cm to prevent the intrusion a. Store at room temperature and in a dry place.
of a foreign substance in the fixture. b. The fixture, fixture mount and cover screw have been cleaned and sterilized
To open, press the upper dotted area Remove the moisture-resistant paper on the
2) Surgery - The second stage by radiation (gamma irradiation) and are ready to use. and take out the sterilized blister. back of the blister, and drop the ampule
a. Incise gingival of upper part of fixture subsequent to bone fusion and remove c. Product packages should be opened just before their use during operation lightly on the palm of a practitioner or
Cover Screw, tighten up Healing Abutment and start gingival curing for prosthesis. and any product beyond the expiration date should not be used.
b. In general, surgery is done by a method that makes prosthesis. d. Only appropriate sterilized surgical tools made specifically for dental implants surgical clothes.
should be used during the operation.
1 2
training be undertaken since the surgical techniques required to place dental under any circumstances if is open. Hold the ampule with both hands, twist Fasten in two ways.
implants are highly specialized and complex procedures. Improper patient b. Every product is disposable. It should not be reused.
selection and technique can contribute to fixture failure and/or loss of supporting it 45°, and separate the middle part. 1) No Mount -> Fasten the Fixture Driver. Y
REGENERATIVE SOLUTION
Separate the upper part of the ampule.
completely. Care must be taken to prevent
patient from swallowing the Cover Screw at
COWELL®
the time of placing.
Hybrid S Ti-Base
PRODUCT NAME Dental Implnat
CATALOG No. 2SLH524
SIZE Ø5X3.75mm C:2(Sub.Hex)
LOT NO. 20A090004A
DATE OF 2020-01-09
REID
MANUFACTURE
USE BY Not Applicable (N/A)
PACKING UNIT 1SET
STORAGE CONDITION Store at room temperature and in a dry place.
Consult 30˚C
Do Not Caution Instructions
Reuse for Use 1˚C
(01) 08800016104301
(11) 200109
(10) 20A090004A
(21) 0001
Rx Only
MEDICAL DEVICE CWM-L-006 (Rev.4)
REGENERATIVE SOLUTION
COWELL®
014 PACKAGE SYSTEM
COWELLMEDI HISTORY
SLA-SH® Surface Treatment
by Nano/CaP soaking technology
SLA-SH®:
Sandblasted, Large-grit, Acid-etched and Super-Hydrophilised
> Hydrophilicity by activation with neutralization solution & Nano/CaP soaking technology.
Experience the > Sandblasted with biocompatible grits unlike majority of other implants in market are done with Alumina.
> Macro-pore & micro-pore of Ti-oxide layer mimicking the etched enamel rod of tooth.
REID
superiority of SLA-SH ®
> Even distribution of roughness through the whole portion of implant surface.
> No destruction or alternation of the surface are caused even with torque force of 120 N.cm.
> Acceleration of osseointegration and maximization of BIC.
made by "Nano/CaP soaking technology" > The SLA-SH® is applied for all types of the COWELL® Implant Systems.
" #
REGENERATIVE SOLUTION
Aspiring for 100% perfection with SLA-SH® > Sand-blasted surface conditions were observed in the product A, B and C due to insufficient acid etching patterns in deep parts
as the SLA-SH® is sandblasted with biocompatible grits with even particle size unlike others are done with alumina.
COWELL®
by Nano/CaP soaking technology > The entire surface of the SLA-SH® treated implant showed uniform acid etching patterns. This implies that the
acid etching of the SLA-SH® surface is perfect.
SLA-SH® 017
SLA-SH®
COWELLMEDI HISTORY
2. Evaluation using SSEM (Stereo Scanning Electron Microscope) 3D images 3. The surface activity increased due to the great surface wetness
A. SLA-SH® Surface A. Contact angle measurement evaluation result for the saline solution
Measurement Info
REID
Magnification : 19.93
Measurement Mode : VSI
Sampling : 496.74 nm
After hydrophilicity After superhydrophilicity
Array Size : 640 X 480 After SLA treatment (133.06°)
activation treatment (36.33°) activation treatment (9°)
After neutralization process and Nano/CaP soaking treatment, the sample became extremely hydrophilic
Surface Stats and the surface energy increased, which facilitated expedition of osteoblast activation to be fused to the bone faster.
Ra : 1.95 ༁
Measurement Info
Capillarity in the actual clinical setting, which accelerated the penetration of blood.
Magnification : 19.93 Quoted from the website of Cowellmedi Clinical Research Group (www.e-cowellmedi.com)
Measurement Mode : VSI
Sampling : 496.74 nm
Array Size : 640 X 480 Blood Friendly
A B C SLA-SH®
After SLA treatment (Ra: 1.78༁) After super-hydrophilicity activation treatment (Ra: 1.90༁)
> There was almost no difference of surface roughness and micro-geometry, and the difference of surface wetness took place
in the same physicochemical properties as surface energy increased by hydrophilicity activation treatment.
> Surface wetness was improved by increased surface energy of C1s, O1s and Ti2p after hydrophilicity activation treatment.
REGENERATIVE SOLUTION
> To maintain and even to enhance surface wetness, superhydrophilicy activation treatment was carried out and contamination
by carbon in the atmosphere is prevented during packing and sterilization.
COWELL®
018 SLA-SH® SLA-SH® 019
COWELLMEDI HISTORY
4. Its safety has been proven through perfect cleaning with an automated system COWELL® CLASS 1000
A. Comparison of surface element tests through X-ray diffraction A SUBTLE DIFFERENCE MAKES THE DENTAL IMPLANT OR NOT
" # $ SLA-SH®
1. Fixture manufacturing tolerance evaluation
A1
a. The specimen was fixed in Jig.
REID
Method b. Each dimensional difference of 3 inner hexagonal connection sides
> Cutting-edge automated system that produces the 3rd distilled water. (Hex-1, Hex-2, Hex-3) of 5 specimens was measured.
C4
C2
C1 Used Equipment Measuring Microscope and Jig
A2
B3
C3
Each dimensional difference of 3 inner hexagonal sides should be
Criteria
B. Comparison of surface element tests (X-ray Photo-electron Spectroscopy, XPS) no more than ±0.001mm (1.000༁) from 2.500mm.
Unit : % INNO SLA-SH® Submerged Fixture (5 Pieces of ST4510S)
Specimen
Sample C1s O1s Ti2p Si2p N1s #1 #2 #3 #4 #5
B2
B1
A4
A3
$ 32.19 47.58 17.58 2.65 N.D Hex-3 2.500 2.500 2.500 2.501 2.499
SLA-SH® 27.19 50.81 17.61 N.D N.D Average 2.500 2.500 2.500 2.500 2.500
Total Average 2.500
Result (Pass/Fail) Pass
> Quantitative analysis of each surface element found 30% carbon, 47% oxygen, 16% titanium and 4% silicon in all products.
Manufacturing No more than
> For the SLA-SH®, they only consisted of carbons(C1s), oxygen(O1s) and titanium(Ti2p). Tolerance ±0.001mm (1.000༁)
B4
> Sodium hydroxide, the main element of the alkali washing solution, combined with silicon(Si) to form water-soluble
Na2SiO2(OH)2·4H2O(water glass), which removed the other elements.
A1
Unit : ppm Method b. Each dimensional difference of 3 outer hexagonal connection
Sample F- Cl- NO2- SO42- Br- NO3- PO43- sides (Hex-1, Hex-2, Hex-3) of 5 specimens was measured.
" N.D 0.024 0.027 0.002 N.D 0.031 N.D Used Equipment Micro-Measuring Instrument
# N.D 0.027 0.019 0.002 N.D 0.030 N.D C
Each dimensional difference of 3 outer hexagonal connection sides should be
C3
Criteria C2
$ C2
no more than ±0.001mm (1.000༁) from 2.490mm.
A2
N.D 0.071 0.020 N.D N.D 0.023 N.D C1
B3
C3
A2
INNO SLA-SH® Sub. Cemented Abutment (5 Pieces of 2SCH4515)
Specimen
A3
> Similar ions were detected in all the products, but they are not harmful to human because their elements and quantities #1 #2 #3 #4 #5
A4
Hex-1 2.489 2.490 2.490 2.490 2.490
B2
do not affect the human body and those have been proven in many studies.
B1
Hex-2 2.490 2.490 2.490 2.490 2.490
> For the SLA-SH®, no other elements except for NO3- were detected. Alkali washing completely removed the SO42- and
B1
Hex-3 2.490 2.490 2.490 2.490 2.491
B2 B4
Cl- ions of sulfuric acid and hydrochloric acid, which are used for heated acid etching because they form water-soluble salts
A3
Average 2.490 2.490 2.490 2.490 2.490
of Na2SO4 and NaCl.
Total Average 2.490
> No elements that interfere with osteo anagenesis were found from both the surface and elution elements, which showing Pass
Result (Pass/Fail)
that the cleansing process was perfectly carried out.
C1
Manufacturing No more than
REGENERATIVE SOLUTION
C2
Tolerance ±0.001mm (1.000༁)
COWELL®
B4
020 SLA-SH® SLA-SH® 021
COWELL® IMPLANT SYSTEM COWELL®
IMPLANT
Volume-up™ Healing Abutment
Help your daily practice superior Devised for preventing food penetration
SYSTEM
and forming aesthetical cervical area by restoring
contracted buccal alveolar bone & gingiva to the
original shape and width.
Milling Abutment
Block abutment to customize contouring.
Fixture type Submerged (Sub.) Submerged Short (Sub.) Internal (Int.) External (Ext.) Submerged Narrow (Sub-N.)
11°
REID
Fixture Design
REGENERATIVE SOLUTION
Depth 5.0mm 26.2 N.cm 29.2 N.cm 26.8 N.cm 28.4 N.cm
Depth 5.5mm 44.0 N.cm 38.0 N.cm 34.4 N.cm 38.5 N.cm
COWELL®
024 INNO-Fixture Design INNO-Fixture Design 025
COWELLMEDI HISTORY
2. Abutment Level Impression - Prosthesis Fabrication
Abutment Prosthetic Protocol * Two / One Piece Screw Retained Abutment
> For digital procedure, refer to the COWELL® Digital Products.
Submerged & Submerged Short : Multi S | Multi A | Lock | SFIT Absolute
Submerged Narrow : Multi S | Multi A
1. Fixture Level Impression - Prosthesis Fabrication
* Two Piece Screw Retained Abutment * One Piece Cemented Retained Abutment
Submerged & Submerged Short : Absolute | Straight (Direct)
Submerged & Submerged Short : Temporary | Easy Temporary | SFIT S | SFIT A Submerged Narrow : Straight
Internal : SFIT S | SFIT A Internal : Solid | Shoulder
External : Temporary External : Shoulder
REID
* Two / One Piece Attachment Retained Abutment
Submerged & Submerged Short : Cemented | Angulated | Beauty-up™ | Milling | Meta G UCLA | Plastic UCLA Submerged & Submerged Short : Sonator S | Sonator A | Ball
Hybrid S | Hybrid L | Hybrid A | Ti-Block Internal : Sonator S | Ball
Submerged Narrow : Cemented | Angulated | Temporary | Meta G UCLA | Hybrid S | Hybrid L | Hybrid A External : Ball
Internal : Cemented | Angulated | Meta G UCLA | Hybrid S | Hybrid L
External : Cemented | Angulated | Temporary | Meta G UCLA | Plastic Sleeve Indirect Impression Technique
(No Abutment Modification Applied) Multi Pick-up Sonator Impression
Ø4.5 Abutment Ø5.5 Abutment Ø6.5 Abutment Impression Coping Multi Transfer Post Coping
(with Open Tray)
Pick up (Open Tray)
Remove the Connect the abutment Wax build-up Complete final Try-in final
Healing Abutment. with replica in the cast model. on the abutment. prosthesis. prosthesis
Direct Impression Technique (Abutment Modification Applied)
with the fixture.
Connect the Transfer Post & Guide Pin and Connect the Replica Interlock the Transfer Post
REGENERATIVE SOLUTION
take the impression with closed tray. with the Transfer Post into the impression tray,
removed from form the gum and pour stone
Single Crown : Hex / Octa Type the impression tray. into the tray for working cast.
Bridge: Non-Hex / Non-Octa Type
Complete final Try-in final prosthesis
COWELL®
The working cast Wax build-up
with the gum. on the abutment. prosthesis. with the fixture.
036p 036p 037p 037p 037p 038p 038p 038p 039p 040p 040p 040p
Fixture Level
Procedure I
Impression
Prosthetic
REID
Cemented Angulated Beauty-up™ Milling Easy Temporary Temporary Meta G UCLA Plastic UCLA Replica Bite Impression Pick-up Impression Transfer Post
Coping Coping
042p 042p 043p 043p 043p 044p 044p 044p 045p 045p
Procedure II
Prosthetic
Multi S Multi A Multi Multi Impression Multi Multi Multi Meta G Multi Plastic Multi Titanium Multi Polishing
Hex 2.5
Length
7 / 8 / 10 Lock
12 / 14 Lock Lock Pick-up Lock Lock Meta G Lock Titanium
16 / 18mm Protection Cap Impression Coping Lab Analog UCLA Cylinder Cylinder
Abutment Level
053p
Procedure V
Impression
Prosthetic
Direct
Impression
059p 059p
Procedure VII
REGENERATIVE SOLUTION
Prosthetic
COWELL®
Ball Ball Analog
Diameter
Ø3.5
Length
Submerged Fixture 7 -
SUB.
HEXAGON Surface Treatment : SLA-SH® 8 ST3508SM
Hex
8 10 12 14
SYSTEM > Interchangeable with hexagonal morse tapered fixture 10 ST3510SM L
> Internal hex connection (Taper 11°/ Hex 2.5)
12 ST3512SM
REID
14 ST3514SM D
7 ST4007SM
8 ST4008SM
7 8 10 12 14 16 18
10 ST4010SM
18 ST4018SM
Diameter
Ø4.5
L Length
7 ST4507SM
Diameter
INNO Fixture Code Length
Ø5.0
12 ST5012SM
S T 40 10 S Ex.) 14 ST5014SM
D
Type body Diameter Length Surface Treatment Mount SLA Pre-Mount ST4010S
Submerged Taper Ø4.0 10mm SLA Pre-Mount
Diameter
Ø6.0
Length
7 ST6007SM
7 8 10 12
REGENERATIVE SOLUTION
8 ST6008SM
L
10 ST6010SM
12 ST6012SM
COWELL®
D
14 -
Diameter
> Packing unit : 1 Fixture + 1 Cover Screw + 1 Mount.
INNO Submerged Short Implant
Ø3.5
Length
8 10 12 14
7 - Submerged Short Fixture
8 ST3508S Hex SUB.
HEXAGON Surface Treatment : SLA-SH®
10 ST3510S L
SYSTEM > Interchangeable with Hexagonal Morse Tapered Fixture.
12 ST3512S > Internal hex connection (Taper 11°/ Hex 2.5).
14 ST3514S D
REID
Diameter
Ø4.0
Hex 2.5
Length
7 ST4007S 7 8 10 12 14 16 18
8 ST4008S
10 ST4010S
12 ST4012S L
Diameter
Ø4.5
L(SLA)
Length
7 8 10 12 14 16 18
7 ST4507S
8 ST4508S
D
10 ST4510S
D
Diameter D
Ø6.0
Length
7 8 10 12
7 ST6007S Diameter 4
Ø5.0
Length
8 ST6008S
L 1
10 ST6010S 2
REGENERATIVE SOLUTION
4 2ST5004S
12 ST6012S L
14 - D
COWELL®
D
Abutment Screw
Cover Screw
REID
D Diameter
Length Ø3.35 Ø3.75 Ø4.15
(15°) (25°) (15° 5mm) (25° 5mm)
L 2SCS000
3
4.2 2SCS001
5.2 2SCS002
> Packing unit : 1 Cover Screw. *Extra Product (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)
> To seal the conical interface of fixture.
Cemented Angulated Beauty-up™ Milling
> The longer Cover Screw for deeply inserted fixture. Abutment Abutment Abutment Abutment
> Tightened with the 1.2 Hex Driver.
Healing Abutment
D
Diameter Ø4.5 Ø5.5 Ø6.5 (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)
L
C Length
Cuff 1 2 1 2 1 2 Easy Temporary Temporary Meta G UCLA Plastic UCLA
Abutment Abutment Abutment Abutment
1 2HS4511 2HS5511 2HS6511
2 2HS4522 2HS5522 2HS6522
3 2HS4532 2HS5532 2HS6532
4 2HS4542 2HS5542 2HS6542
5 2HS4552 2HS5552 2HS6552
L
Diameter Ø6.5 Ø7.5 Ø8.5
Length
H C Cuff 2 2 2
7.9
3 VUHN6532 VUHN7532 VUHN8532
> Packing unit : 1 Abutment(Inbuilt Abutment Screw).
> Used for an implant procedure to form the gingival tissue and alveolar bone in the form 1mm
of natural teeth and gums by prevention or minimizing the food penetration. off-centered
> Extremely effective when used with the COWELL® BMP.
> Recommended to use with the Volume-up™ Guide System.
> Select according to gingival height and abutment type.
REGENERATIVE SOLUTION
> Tightened with the 1.2 Hex Driver.
> Tightening torque force : 25~35 N.cm.
Healing
COWELL®
Fixture Cover Screw Abutment
REID
Type N-Hex allows more esthetic prosthesis. > Fixture level impression.
Diameter Ø4.5 Ø5.5 Ø6.5 > Oval design allows lower incisal application
(Mesiodistal diameter : 3.8mm).
Length
Cuff 4 5.5 7 4 5.5 7 4 5.5 7
1 2SCN4514 2SCN4515 2SCN4517 2SCN5514 2SCN5515 2SCN5517 2SCN6514 2SCN6515 2SCN6517 * Angulated Screw Ratchet Driver
Type Ratchet
2 2SCN4524 2SCN4525 2SCN4527 2SCN5524 2SCN5525 2SCN5527 2SCN6524 2SCN6525 2SCN6527 Height
24(Short) KRBUD15
3 2SCN4534 2SCN4535 2SCN4537 2SCN5534 2SCN5535 2SCN5537 2SCN6534 2SCN6535 2SCN6537
29(Long) KRBUD20
4 2SCN4544 2SCN4545 2SCN4547 2SCN5544 2SCN5545 2SCN5547 2SCN6544 2SCN6545 2SCN6547 H
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and
5 2SCN4554 2SCN4555 2SCN4557 2SCN5554 2SCN5555 2SCN5557 2SCN6554 2SCN6555 2SCN6557
REGENERATIVE SOLUTION
> Select Hex-A or Hex-B according to case. > Fixture level impression.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
COWELL®
> Fixture level impression.
REID
> Fixture level impression.
REGENERATIVE SOLUTION
COWELL®
038 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 039
COWELLMEDI HISTORY
Bite Impression Coping
D Type Hex(Short) Hex(Long) Hex(X-Long)
Prosthetic Procedure II
Diameter Ø4.5 Ø4.5 Ø4.5 Component Selection Guide for Multi S&A Abutment
L
Cuff
Length 2 4 6
C 4.0 2SBIC45S 2SBIC45L 2SBIC45X
REID
Hex Multi Cylinder Screw
C
16 (Long) / 4 2SIH45L 2SIH55L 2SIH65L 2SIN45L 2SIN55L 2SIN65L
> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (2SISR001SS / 2SISR001SL).
Lab Analog
> For open tray impression.
(Short) (Short) (Long) (Short) (Short) (Long)
> Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
2 Pieces
Multi Pick-up
Impression Coping Multi Transfer Post
Transfer Post
D
Type Hex N-Hex
Diameter Multi Protection Cap
Hex N-Hex
REGENERATIVE SOLUTION
COWELL®
Healing
Fixture Cover Screw Abutment
REID
> Gold color for more translucent restoration.
> Integrated with screw and abutment.
> Library available for EXOCAD®, 3Shape® & Others.
> Use the S Holder for more stable position.
> Tightened with the S Machine & S Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.
Abutment Screw > Packing unit: 1 Multi Transfer Post + 1 Guide Pin (2SMTHS100).
1.2 Hex. Height > For closed tray impression.
Diameter 7.5 6.5 > Connected with the Guide Pin.
Hex N-Hex
D
2.15 2SSHR300 2SSHR400 > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.
> Packing unit: 1 Abutment Screw.
H > To connect the Multi A Abutment.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
REGENERATIVE SOLUTION
COWELL®
042 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 043
COWELLMEDI HISTORY
Multi Lab Analog Multi Titanium Cylinder Type Hex N-Hex
D Multi S & A Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
L 1.2 Hex.
Diameter Ø4.5 Ø5.5
Length Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
L Length
2 2SMA45 2SMA55 2.25 Cuff 8.5 8.5 8.5 8.5
> Packing unit : 1 Multi Lab Analog. 0.5 2STCH45 2STCH55 2STCN45 2STCN55
C
> Replacement of abutment shape in working cast. D
> Choose by abutment size. > Packing unit : 1 Multi Titanium Cylinder + 1 Cylinder Screw.
> For Screw, Cement or Screw-Cement Retained Prosthesis.
> Connected with the Cylinder Screw.
Hex N-Hex > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
REID
COWELL® IMPLANT SYSTEM
Multi Meta G UCLA Cylinder Type Hex N-Hex Multi Cylinder Screw
Diameter
Multi S & A
Ø4.5 Ø5.5 Ø4.5 Ø5.5 Height Ø2.25
Abutment Diameter
1.2 Hex. 1.2 Hex.
Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5 5 2SMCS100
L Length
2.25 Cuff 10.9 10.9 10.9 10.9 D > Packing unit : 1 Multi Cylinder Screw.
0.5 2SCCH45 2SCCH55 2SCCN45 2SCCN55 > Connected with the Meta G UCLA, Plastic UCLA and Titanium Cylinder.
H > Tightened with the 1.2 Hex Driver and Torque Wrench.
C
D > Packing unit : 1 Multi Meta G UCLA Cylinder + 1 Multi Cylinder Screw. > Tightening torque force : 30 N.cm.
> For Screw, Cement or Screw-Cement Retained Prosthesis.
> Modification to various types of abutments.
> CCM alloy core for precise connection.
Hex N-Hex
> Cast with non-precious metal or gold alloy.
Multi Plastic UCLA Cylinder Type Hex N-Hex Multi Polishing Protector Type Hex
REGENERATIVE SOLUTION
COWELL®
044 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 045
COWELLMEDI HISTORY
Multi Holder Prosthetic Procedure III
H
Component Selection Guide for Lock Abutment
Type
Height Hand
20 KMHS01
S Holder > Packing unit : 1 Holder.
> To position the Multi S Abutment more stably.
H
Type
Height Hand
Lock Cylinder Screw
REID
20 KMHA01
A Holder
> Packing unit : 1 Holder.
> To position the Multi A Abutment more stably.
1.2 Hex Driver
REGENERATIVE SOLUTION
Healing
Fixture Cover Screw Abutment
COWELL®
046 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 047
COWELLMEDI HISTORY
Lock Abutment Diameter Ø4.5 Lock Lab Analog
Diameter
D Length
2.15 D Length Ø4.5
Cuff
L
L 0.5 2SLA400 2.15 2SLA45
C
1 2SLA410 > Packing unit : 1 Lock Lab Analog.
2 2SLA420
> Replacement of abutment shape in working cast.
> Connected with the Guide Pin.
3 2SLA430 > Tightened with the 1.2 Hex Driver and Torque Wrench.
4 2SLA440
REID
> Integrated with screw and abutment.
> Tightened with the Lock Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.
REGENERATIVE SOLUTION
COWELL®
048 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 049
COWELLMEDI HISTORY
Lock Cylinder Screw
1.2 Hex. Height
Diameter
Ø2.3
Prosthetic Procedure IV
4.8 2SLCS200 Component Selection Guide for Absolute Abutment
D
> Packing unit : 1 Cylinder Screw.
H > Connected with the CCM Cylinder or Titanium Cylinder.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
(Crown) (Bridge)
REID
Absolute Plastic Coping
H
28.5 KRLRD28
> Packing unit : 1 Lock Ratchet Driver. Absolute Impression Cap
> To install the Lock Abutment by hand.
Healing
Fixture Cover Screw Abutment
REGENERATIVE SOLUTION
COWELL®
050 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 051
COWELLMEDI HISTORY
Absolute Abutment
Diameter Ø4.5 Ø5.5 Prosthetic Procedure V
D Length
Cuff 4 5.5 7 4 5.5 7
Component Selection Guide for Straight Abutment
L
1 2SAC4514 2SAC4515 2SAC4517 2SAC5514 2SAC5515 2SAC5517
2 2SAC4524 2SAC4525 2SAC4527 2SAC5524 2SAC5525 2SAC5527
C
3 2SAC4534 2SAC4535 2SAC4537 2SAC5534 2SAC5535 2SAC5537
1.2 Hex Driver
4 2SAC4544 2SAC4545 2SAC4547 2SAC5544 2SAC5545 2SAC5547
5 2SAC4554 2SAC4555 2SAC4557 2SAC5554 2SAC5555 2SAC5557
Diameter Ø6.5
> Packing unit : 1 Absolute Abutment + 1 Production Cap.
Length
> For Cement Retained Prosthesis.
REID
Cuff 4 5.5 7 > Cutting surface for anti-rotation of prosthesis.
1 2SAC6514 2SAC6515 2SAC6517 > Integrated with the Screw and Abutment. Straight Abutment
> Tightened with the 1.2 Hex Driver and Torque Wrench.
2 2SAC6524 2SAC6525 2SAC6527 > Tightening torque force : 30 N.cm.
3 2SAC6534 2SAC6535 2SAC6537 > Abutment level impression.
4 2SAC6544 2SAC6545 2SAC6547
5 2SAC6554 2SAC6555 2SAC6557
H Diameter
Absolute Plastic Coping (Burn Out Cylinder) Height Ø4.5
D 19 KRR19L
Type Crown Bridge
> Packing unit : 1 Driver.
H H Abut. Diameter Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5 > To install the Straight Abutment.
Diameter
Ø5.1 Ø6.1 Ø7.1 Ø5.1 Ø6.1 Ø7.1
REGENERATIVE SOLUTION
Height
D
10 2SHBC45 2SHBC55 2SHBC65 2SHBB45 2SHBB55 2SHBB65
COWELL®
Crown Bridge > Connected with the Lab Analog.
> Burn out and casting for metal framework.
Ø5.4
Bule : 10N Pink :15N White : 22N
Black Carrier
Block-out Processing
Outer Cap Spacer Male
Diameter Ø4.0
Cuff
REID
Length 1 2 3 4 5 6
1.5 SONS401 SONS402 SONS403 SONS404 SONS405 SONS406
> Packing unit : Sonator S Abutment + Carrier + 3 H-Type Inner Caps + Outer Cap + Block-out Spacer + Black Processing Male.
> For Implant Supported Over-denture Prosthesis.
D Ratchet Driver
> Stable with low vertical height.
L > 6 kinds of the Inner Caps give various holding force (Both, H and NH-Type Inner Caps are used for the Sonator S Abutment).
H-Type Inner Caps NH-Type Inner Caps > Path compensation up to 20° based on 2 implants.
C
> Carrier : Used for delivery of the abutment.
> Tightened with the Sonator S Ratchet Driver and Torque Wrench.
Sonator A Abutment
Black
Block-out Processing
Outer Cap Spacer Male NH-Type Inner Caps
2.25mm
Analog
Diameter Ø4.0
Carrier
Length 1.5 3.0
Impression Coping Cuff 3 3
Angle
15° SONA415 SONA430
> Packing unit : Sonator A Abutment + Abutment Screw + Carrier + 3 NH-Type Inner Caps + Outer Cap
D 1.2 Hex Driver + Block-out Spacer + Black Processing Male.
> For Implant Supported Over-denture Prosthesis.
Abutment Screw
1.2 Hex.
Healing
Fixture Cover Screw
REGENERATIVE SOLUTION
Abutment D
Diameter
Height Ø2.15
H 7.5 2SSHR300
COWELL®
054 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 055
COWELLMEDI HISTORY
Outer Cap Sonator Lab Analog
Diameter Diameter
D
Black Processing Male Height Ø5.4 Length Ø4
D
2.25 SONOC01 8.8 SONLA04
H
> Packing unit : 2 Outer Caps and 2 Black Processing Males. > Packing unit : 4 Lab Analogs.
> Black Processing Male: Inserted and removed with the I&R Driver. > Replacement of abutment shape in working cast.
L
REID
H-Type Inner Cap Code SONIC01
> Packing unit : 3 Block-out Spacers + 3 Inner Caps (1 Blue, 1 Pink and 1 White).
Block-out
> Path compensation up to 20° based on 2 implants.
Spacer Inner Cap > Mainly used for the Sonator S Abutment.
> Inner Caps: Inserted and removed with the I&R Driver.
Sonator Impression Coping > Used to insert and remove the Inner Caps and Block Processing Male.
Diameter
Length Ø4.8
D
Black Processing Male
3 SONIP04
L
> Packing unit : 4 Impression Copings and 4 Black Processing Males.
> Connected over the Sonator Abutment after placing the Block-out Spacer.
> For close tray impression.
REGENERATIVE SOLUTION
COWELL®
056 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 057
COWELLMEDI HISTORY
Prosthetic Procedure VII Ball Abutment
Outer Cap Block-out Spacer
Diameter
Length
Ø4.0
4
Cuff
Component Selection Guide for Ball Abutment 1 2SBAT414R
2.4mm
Ø3.4 2 2SBAT424R
3 2SBAT434R
4 2SBAT444R
5 2SBAT454R
Red : 10N Orange : 15N Green : 20N
Ball Inner Cap > Packing unit : 1 Ball Abutment + 3 Inner Caps (1 per each colour) + 1 Block-out Spacer + 1 Outer Cap.
D > For Implant Supported Over-denture Prosthesis.
> Tightened with the Ball Driver and Torque Wrench.
REID
L
> Tightening torque force : 30 N.cm.
Ball Outer Cap Block-out Spacer > Direct impression.
C
Ball Abutment
Ball Abutment
REGENERATIVE SOLUTION
For Removal For Insertion
COWELL®
> Packing unit : 1 I&R Driver.
> Used to insert and remove the Inner Caps into and out of the Outer Cap.
REID
065p 065p 065p 066p 066p 067p 067p
Fixture Level
Procedure I
Impression
Prosthetic
Hex 2.1
063p 063p 070p 070p 070p 071p 071p 071p 072p 072p
Length Multi Multi Impression Multi Multi Multi Meta G Multi Plastic Multi Titanium Multi Polishing
8 / 10 / 12 / 14mm Protection Cap Coping Transfer Post Lab Analog ULCA Cylinder UCLA Cylinder Cylinder Protector
Multi S Multi A
Diameter
Ø3.1 / 3.3
Abutment Level
Impression
Direct
Impression
Straight
REGENERATIVE SOLUTION
COWELL®
060 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 061
COWELLMEDI HISTORY
INNO Submerged Pre-Mount > Packing unit : 1 Fixture + 1 Cover Screw + 1 Mount.
8 SR3108NS
L
10 SR3110NS
Submerged Fixture 12 SR3112NS
SUB-N. Note
HEXAGON Surface Treatment : SLA-SH® 14 SR3114NS D
> The INNO Sub. Narrow System is not compatible with
SYSTEM > Interchangeable with hexagonal morse tapered fixture. the INNO Submerged System as hexagon size is different.
REID
> Internal hex connection (Taper 11°/ Hex 2.1).
Diameter
Ø3.3
Length 8 10 12 14
12 SR3312NS
14 SR3314NS
Fixture Mount
Length 5.4
L
RSM001
> Packing unit : 1 Mount + 1 Mount Screw.
L > Tightened with the 1.2 Hex Driver.
> Tightening torque force : 5~10 N.cm.
10 SR3310NSM L 5 HS4552N
REGENERATIVE SOLUTION
12 SR3312NSM 7 HS4572N
14 SR3314NSM D
> Packing unit : 1 Abutment.
> For remodeling gingival contour during soft tissue healing.
COWELL®
> Select according to gingival height and abutment type.
> Tightened with the 1.2 Hex Driver.
> Tightening torque force : 5~10 N.cm.
Components Selection Guide for Cemented and UCLA Abutment D Diameter Ø4.5 Ø4.5
2.25 Length
L Cuff 4 5.5 7 4 5.5 7
C
1 SCH4514N SCH4515N SCH4517N SCN4514N SCN4515N SCN4517N
2 SCH4524N SCH4525N SCH4527N SCN4524N SCN4525N SCN4527N
3 SCH4534N SCH4535N SCH4537N SCN4534N SCN4535N SCN4537N
4 SCH4544N SCH4545N SCH4547N SCN4544N SCN4545N SCN4547N
2.25 Hex N-Hex 5 SCH4554N SCH4555N SCH4557N SCN4554N SCN4555N SCN4557N
> Packing unit : 1 Cemented Abutment + 1 Abutment Screw.
> For Screw-Cement or Cement Retained Prosthesis.
REID
> Cutting surface for anti-rotation of prosthesis.
Abutment Screw > Gold color for more translucent restoration (Hex) and classification with N-Hex.
> Library available for EXOCAD®, 3Shape® & Others.
> Connected with the Abutment Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work.
> Fixture level impression.
(Hex) (N-Hex) (Hex) (Hex) (N-Hex) (Hex) (N-Hex)
Healing
REGENERATIVE SOLUTION
Fixture Cover Screw Abutment
COWELL®
064 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 065
COWELLMEDI HISTORY
Meta G UCLA Abutment Type Hex N-Hex Pick-up Impression Coping Type Hex N-Hex
D
Diameter Ø4.5 Ø4.5 Diameter
D 1.2 Hex. Length / Cuff Ø4.5 Ø4.5
Length
Cuff 12 12 14 (Short) / 2 SIH45SN SIN45SN
2.25 L
1 SGH45N SGN45N 16 (Long) / 4 SIH45LN SIN45LN
2 Pieces
L 2 SGH452N SGN452N
C
3
> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin.
SGH453N SGN453N
C > For open tray impression.
> Packing unit : 1 Abutment + 1 Abutment Screw. (Short) (Long) (Short) (Long)
> Connected with the Guide Pin (SIS001SN / SIS001LN).
> For Screw Retained Prosthesis. > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Modification to angulated abutment, customized abutment and telescopic abutment.
Hex N-Hex > CCM alloy core for precise connection.
Hex N-Hex
REID
> Cast with non-precious metal or gold alloy.
> Connected with the Abutment Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
> Fixture level impression.
2 Pieces 1 Piece
Replica D
REGENERATIVE SOLUTION
COWELL®
066 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 067
COWELLMEDI HISTORY
Prosthesis Procedure II Multi S Abutment Diameter Ø4.5
Length 2
Component Selection Guide for Multi S&A Abutment D Cuff
1 SMS451N
L
C 2 SMS452N
1 Piece 3 SMS453N
4 SMS454N
REID
Multi Cylinder Screw > Library available for EXOCAD®, 3Shape® & Others.
> Use the S Holder for more stable position.
> Tightened with the S Machine & S Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.
C 3 SMAH45153BN SMAH45303BN
4 SMAH45154BN SMAH45304BN
Abutment Screw
1.2 Hex. Height
Multi S Abutment Multi A Abutment Diameter 8.7 9.3
Ø1.95 SSHR200N SSHR300N
D
REGENERATIVE SOLUTION
COWELL®
Healing
Fixture Cover Screw Abutment
> Packing unit : 1 Multi Protection Cap. > Packing unit : 1 Multi Lab Analog.
> Protection from cheek and tongue for gingival healing period. > Replacement of abutment shape in working cast.
> Gingival retraction for prosthodontic margin of abutment.
> Alternative usage for sub-structure of temporary prosthesis.
REID
COWELL® IMPLANT SYSTEM
Multi Pick-up Impression Coping Multi Meta G UCLA Cylinder
D Type Hex N-Hex
Type Hex N-Hex
1.2 Hex. Multi S & A
Multi S & A Abutment Diameter Ø4.5 Ø4.5
Abutment Diameter Ø4.5 Ø4.5
L Diameter Ø4.5 Ø4.5
Diameter
Length Ø4.65 Ø4.65 2.25
L Length
Cuff 10.9 10.9
14.8 2SMIH45 2SMIN45
C 0.5 2SCCH45 2SCCN45
> Packing unit: 1 Multi Pick-up Impression Coping + 1 Guide Pin (2SMGP012). D
> For open tray impression. > Packing unit : 1 Multi Meta G UCLA Cylinder + 1 Multi Cylinder Screw.
> Connected with the Guide Pin. > For Screw, Cement or Screw-Cement Retained Prosthesis.
> Tightened with the 1.2 Hex Driver and Torque Wrench. Hex N-Hex > Modification to various types of abutments.
Hex N-Hex > Tightening torque force: 12~15 N.cm. > CCM alloy core for precise connection.
> Packing unit: 1 Multi Transfer Post + 1 Guide Pin (2SMTHS100). 0.5 2SMPH45 2SMPN45
C
> For closed tray impression.
Hex N-Hex > Connected with the Guide Pin.
D > Packing unit : 1 Multi Plastic UCLA Cylinder + 1 Multi Cylinder Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench. > For Screw, Cement or Screw-Cement Retained Prosthesis.
> Tightening torque force: 12~15 N.cm. > Same purpose of use as the Meta G UCLA Cylinder but low accuracy of connection.
Hex N-Hex
> PMMA material.
> Connected with the Multi Cylinder Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
REGENERATIVE SOLUTION
COWELL®
070 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 071
COWELLMEDI HISTORY
Multi Titanium Cylinder Multi Holder
Type Hex N-Hex
1.2 Hex.
Multi S & A
Abutment Diameter Ø4.5 Ø4.5 H
L Diameter Ø4.5 Ø4.5 Type
2.25 Hand
Height
Length
Cuff 8.5 8.5
C 20 KMHS01
0.5 2STCH45 2STCN45
D S Holder > Packing unit : 1 Holder.
> Packing unit : 1 Multi Titanium Cylinder + 1 Cylinder Screw. > To position the Multi S Abutment more stably.
> For Screw, Cement or Screw-Cement Retained Prosthesis.
Hex N-Hex > Connected with the Cylinder Screw. H
> Tightened with the 1.2 Hex Driver and Torque Wrench. Type
> Tightening torque force : 30 N.cm. Height Hand
REID
20 KMHA01
A Holder
> Packing unit : 1 Holder.
> To position the Multi A Abutment more stably.
1.2 Hex Driver
REGENERATIVE SOLUTION
COWELL®
072 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 073
COWELLMEDI HISTORY
Prosthesis Procedure III
Component Selection Guide for Straight Abutment
REID
Straight Abutment
Straight Abutment
D
Diameter Ø3.5
7 5.5 L Length [Cuff] 8 [0.5] 8 [1] 8 [2] 8 [3] 8 [4]
REGENERATIVE SOLUTION
COWELL®
074 INNO-SUB. NARROW IMPLANT
COWELLMEDI HISTORY
INNO INTERNAL IMPLANT (Int.)
System Flow
REID
Fixture Level
083p 083p 083p 084p 084p 084p
Procedure I
Impression
Prosthetic
Platform
Ø4.8 / 5.9
Cuff
089p 089p 089p 089p 089p
Length Shoulder
7 / 8 / 10 / 12 / 14mm Shoulder Shoulder Shoulder
Positioning
Abutment Level
Shoulder Abutment Cap Impression Cap Lab Analog
Cylinder
Impression
Diameter
Ø3.5 / 4.0 / 4.5 / 5.0 / 6.0
091p 092p 092p
Procedure IV
Prosthetic
095p 095p
Procedure V
Prosthetic
Ball Analog
Ball
REGENERATIVE SOLUTION
COWELL®
076 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 077
COWELLMEDI HISTORY
INNO Internal Impant (Int.) No-Mount Cuff 1.8mm fixture > Packing unit : 1 Fixture + 1 Cover Screw.
* Diameter
Ø3.5
Length
Internal Fixture * Platform : Ø4.8
INT. Surface Treatment : SLA-SH® 7 - C
OCTAGON Platform 8 10 12 14
> Interchangeable with 1 staged internal fixture.
SYSTEM 8 IPT3508SM
> Internal Octa Connection (Taper 8°/ Octa 3.1). L
> No-Mount type. 10 IPT3510SM Fixture
Diameter
12 IPT3512SM
REID
14 IPT3514SM D
Octa 3.1
* Diameter
Ø4.0
Length
Platform * Platform : Ø4.8
7 IPT4007SM
C 7 8 10 12 14
8 IPT4008SM
* Diameter
Ø4.5
Length
L 7 IPT4507SM
* Platform : Ø4.8
C 7 8 10 12 14
8 IPT4508SM
L
10 IPT4510SM
* Diameter
Ø5.0
D Length
* Platform : Ø5.9
7 IPT5007SM C 7 8 10 12 14
8 IPT5008SM
INNO Fixture Code L
10 IPT5010SM
P
* Diameter
Ø6.0
I T 40 10 S M Ex.)
SLA Cuff 2.4 No-Mount IT4010SM
Length
* Platform : Ø5.9
Type Cuff 2.4 body Diameter Length Surface Treatment Mount C 7 8 10 12
7 IPT6007SM
Internal Taper Ø4.0 10mm SLA No-Mount
8 IPT6008SM L
10 IPT6010SM
12 IPT6012SM
D
14 -
REGENERATIVE SOLUTION
COWELL®
078 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 079
COWELLMEDI HISTORY
No-Mount Cuff 2.4mm fixture > Packing unit : 1 Fixture + 1 Cover Screw. Cover Screw
D
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Diameter
Length Ø5.0 Ø6.0
L
* Diameter
Ø3.5 6.5 ICVR002 ICVW002
Length
* Platform : Ø4.8 > Packing unit : 1 Cover Screw.
> To seal the conical interface of fixture.
7 - C
Platform 8 10 12 14 > Tightened with the 1.2 Hex Driver.
8 IT3508SM > Tightening torque force : 5~10 N.cm.
L
10 IT3510SM Fixture
Diameter
12 IT3512SM
REID
14 IT3514SM D
* Diameter
Ø4.0
Length Headless Screw Diameter
Length Ø3.5
D
* Platform : Ø4.8 6 ICVR001
7 IT4007SM
C 7 8 10 12 14
8 IT4008SM L > Packing unit : 1 Headless Screw.
> For narrow mesio-distal distance.
* Diameter
Ø4.5
Length
* Platform : Ø4.8
7 IT4507SM C 7 8 10 12 14
8 IT4508SM
Healing Abutment
L
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
10 IT4510SM Diameter
D Height Ø5.5 Ø6.6
* Diameter
Ø6.0
Length
* Platform : Ø5.9
C 7 8 10 12
7 IT6007SM
8 IT6008SM L
10 IT6010SM
12 IT6012SM
D
14 -
REGENERATIVE SOLUTION
COWELL®
080 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 081
COWELLMEDI HISTORY
Cemented Extension Abutment
Prosthetic Procedure I D
1.2 Hex.
2.5
Type
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5]
Octa
Ø5.9 [Ø5.0 / Ø6.0]
L6 Diameter
Component Selection Guide for Cemented & UCLA Abutment Cuff Ø4.8 Ø5.8 Ø5.9 Ø6.9
C 0.5 IECR406 IECW506
1 IECR416 IECW516
2 IECR426 IECW526
Octa N-Octa 3 IECR436 IECW536
Type N-Octa
REID
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Diameter
Coping Screw Cuff Ø4.8 Ø5.8 Ø5.9 Ø6.9
0.5 IENR406 IENW506
1 IENR416 IENW516
2 IENR426 IENW526
(15°) (25°) 3 IENR436 IENW536
Angulated Abutment
15° Type Octa
1.2 Hex. Platform [Fixture Dia.] Ø4.8 & Ø5.9 [Ø3.5 / Ø4.0 / Ø4.5 / Ø5.0 / Ø6.0]
(Octa) (N-Octa)
REGENERATIVE SOLUTION
Octa N-Octa
> Cast with non-precious metal or gold alloy.
> Connected with the Abutment Screw (ISHR120).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
COWELL®
> Tightening torque force : 35 N.cm.
> Fixture level impression.
Prosthetic Procedure II
Height
1.2 Hex. 1.2 Hex. 1.2 Hex.
6.3 ISHR100
7.8 ISHR120
D D D
9.2 ISHR110 Component Selection Guide for Solid Abutment
H
> Packing unit : 1 Abutment Screw.
> ISHR110 : Cemented Abutment.
> ISHR100 : Angulated Abutment.
> ISHR120 : Meta G Abutment.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
(Crown) (Bridge)
REID
Solid Plastic Coping
Replica
D Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Diameter
Height Ø4.8 Ø5.9
H 12 IROR001 IROW001
> Packing unit : 1 Replica.
> Mimicking of conical interface of fixture.
Transfer Post
REGENERATIVE SOLUTION
Healing
Fixture Cover Screw Headless Screw Abutment
COWELL®
084 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 085
COWELLMEDI HISTORY
Solid Abutment Solid Positioning Cylinder
D Platform [Fixture Dia.] Ø4.8 & Ø5.9 [Ø3.5 / Ø4.0 / Ø4.5 / Ø5.0 / Ø6.0]
D
Diameter Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5]
L Ø3.5
Diameter
Length 3 4 5.5 7 Height Ø5.7
H 10.2 IPCR001
IASR030 IASR040 IASR055 IASR070
> Packing unit : 1 Solid Abutment + 1 Abutment Cap. > Packing unit : 1 Positioning Cylinder.
> For Cement Retained Prosthesis. > Inner cutting surface for anti-rotation on abutment.
> Cutting surface for anti-rotation of prosthesis. > Insert into the Impression Cap.
> Integrated with screw and abutment.
> Tightened with the Shoulder Driver.
> Tightening torque force : 35 N.cm.
REID
> Abutment level impression :
Impression cap in platform Ø4.1 fixture and direct impression in platform Ø5.8 fixture.
4IPVMEFSⰝ KRR19L
REGENERATIVE SOLUTION
COWELL®
086 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 087
COWELLMEDI HISTORY
Shoulder Abutment Type Crown Bridge
D
REID
> Tightening torque force : 35 N.cm.
> Abutment level impression.
(Crown) (Bridge)
4IPVMEFSⰝ KRR19L 4IPVMEFSⰝ KRW19L
Shoulder Lab Analog
Shoulder Abutment Cap Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Shoulder Positioning Cylinder Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
(Crown) (Bridge) D
Diameter
Shoulder Abutment 5.7 6.8
REGENERATIVE SOLUTION
5.5 SLCR055 SLCW055 SLBR055 SLBW055
7 SLCR070 SLCW070 SLBR070 SLBW070
COWELL®
> Packing unit : 1 Lab Analog.
> Replacement of abutment shape in working cast.
Crown Bridge > Choose according to width and length of abutment.
2.25mm
Ø5.4
Black Bule : 10N Pink : 15N White : 22N
Block-out Processing
Outer Cap Spacer Male
Carrier
Diameter Ø4.0
REID
Cuff 0.6 2 3 4
Length
1.5 IONS401 IONS402 IONS403 IONS404
> Packing unit : 1 Sonator S Abutment + Carrier + 3 H-Type Inner Caps + Outer Cap + Block-out Spacer
+ Black Processing Male.
> For Implant Supported Over-denture Prosthesis.
> Stable with low vertical height.
> 6 kinds of the Inner Caps give various holding force (Both, H and NH-Type Inner Caps are used for Sonator S Abutment).
H-Type Inner Caps NH-Type Inner Caps > Path compensation up to 20° based on 2 implants.
Ratchet Driver
D > Carrier : Used for delivery of the abutment.
REGENERATIVE SOLUTION
Healing
Fixture Cover Screw Headless Screw Abutment
COWELL®
090 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 091
COWELLMEDI HISTORY
NH-Type Inner Cap Code SONIC02 Sonator S Ratchet Driver
H Type
> Packing unit : 3 Block-out Spacers + 3 Inner Caps (1 Red, 1 Orange and 1 Green). Height Ratchet
Block-out > Path compensation up to 40° based on 2 implants. 18 SONRD19L
Spacer Inner Cap > Mainly used for the Sonator A Abutment.
> Inner Caps : Inserted and Removed with the I&R Driver. > Used to tighten and untighten the Sonator S Abutment.
REID
COWELL® IMPLANT SYSTEM
Sonator Impression Coping I & R Driver
Diameter Height 95.4
Length Ø4.8
D
Black Processing Male SONIR002
3 SONIP04
H
L
> Packing unit : 4 Impression Copings and 4 Black Processing Males.
> Abutment level pick-up impression.
> Connected over the Sonator Abutment after placing the Block-out Spacer. For Removal For Insertion
> For close tray impression.
> Used to insert and remove the Inner Caps and Block Processing Male.
REGENERATIVE SOLUTION
COWELL®
092 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 093
COWELLMEDI HISTORY
Ball Abutment
Outer Cap Block-out Spacer
REID
L
Ball Abutment
Ball Abutment
Healing
Fixture Cover Screw Headless Screw Abutment
REGENERATIVE SOLUTION
H
COWELL®
> Packing unit : 1 I&R Driver.
> Used to insert and remove the Inner Caps into and out of the Outer Cap.
REID
102p 102p
Fixture Level
Prosthetic
Impression
Platform
Ø4.1 / 5.1
7 / 8 / 10 / 12 / 14mm
Abutment Level
Impression
REGENERATIVE SOLUTION
COWELL®
096 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 097
COWELLMEDI HISTORY
INNO External Implant (Ext.)
Pre-Mount > Packing unit :1 Fixture + 1 Mount + 1 Mount Screw.
* Diameter
Ø3.5 * Hex 2.7
Length * Platform : Ø4.1
External Fixture
EXT.
Surface Treatment : SLA-SH® 7 -
HEXAGON
SYSTEM > Interchangeable with external hexagonal fixture. 8 ET3508S
>External hex connection (Hex 2.7 / 3.4). 10 ET3510S
12 ET3512S
REID
14 ET3514S
Platform 7
8
ET4007S
ET4008S
* Diameter
Ø4.5 * Hex 2.7
Length * Platform : Ø4.1
L 7 ET4507S
8 ET4508S
10 ET4510S
* Diameter
Ø5.0 * Hex 3.4
Length * Platform : Ø5.1
D
7 ET5007S
8 ET5008S
INNO Fixture Code 10 ET5010S
7 ET6007S
8 ET6008S
10 ET6010S
12 ET6012S
14 -
REGENERATIVE SOLUTION
COWELL®
098 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 099
COWELLMEDI HISTORY
Fixture Mount
D
REID
Abutment Screw
(15°) (25°)
D Hex Hex2.7 Hex3.4 Cemented Angulated Abutment Temporary Abutment Meta G UCLA Abutment Plastic Sleeve
1.1mm Abutment
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
L
Diameter
Length Ø4.3 Ø5.4
5.8 VNR001 VNW001
REGENERATIVE SOLUTION
> Tightened with the 1.2 Hex Driver.
> Tightening torque force : 5~10 N.cm.
COWELL®
100 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 101
COWELLMEDI HISTORY
Cemented Abutment Meta G UCLA Abutment
Type Hex
Hex Hex2.7 Hex3.4 1.2 Hex.
1.2 Hex. Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex
D D
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
L
Diameter Ø5.0 Ø6.0 Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
L L
Length Length
Cuff 6 8 6 8 13 13 13 13
Cuff
C
C C 1 CHR516 CHR518 CHW616 CHW618 1.2 GHR001N GHW001N GNR001N GNW001N
D
2 CHR526 CHR528 CHW626 CHW628 > Packing unit : 1 Abutment + 1 Abutment Screw.
3 CHR536 CHR538 CHW636 CHW638 > For Screw-Cement or Screw Retained Prosthesis.
Hex N-Hex Hex N-Hex > Modification to angulated abutment, customized abutment and telescopic abutment.
4 CHR546 CHR548 CHW646 CHW648
> CCM alloy core for precise connection.
REID
> Cast with non-precious metal or gold alloy.
Type N-Hex > Connected with the Abutment Screw.
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] > Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex > Tightening torque force : 35 N.cm.
Diameter Ø5.0 Ø6.0
Platform > Fixture level impression.
Length
Cuff 6 8 6 8
1 CNR516 CNR518 CNW616 CNW618
2 CNR526 CNR528 CNW626 CNW628
3 CNR536 CNR538 CNW636 CNW638
> Packing unit : 1 Abutment + 1 Abutment Screw. > Tightened with the 1.2 Hex Driver and Torque Wrench.
> For Cement Retained and Screw-Cement Retained Prosthesis. > Tightening torque force : 35 N.cm
> Cutting surface for anti-rotation of prosthesis. > Fixture level impression.
> Connected with the Abutment Screw.
REGENERATIVE SOLUTION
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 20 N.cm.
COWELL®
102 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 103
COWELLMEDI HISTORY
Replica
D Type[Hex]
Platform [Fixture Dia.]
Hex[2.7]
Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5]
Hex[3.4]
Ø5.1 [Ø5.0 / Ø6.0] Prosthetic Procedure II
Diameter
H Height Ø4.1 Ø5.1 Component Selection Guide for Shoulder Abutment
12 LHR001 LHW001
> Packing unit : 1 Replica.
> Mimicking of conical interface of fixture.
> Analog of fixture for working cast.
REID
(Crown) (Bridge)
Hex N-Hex
Healing
Fixture Cover Screw Abutment
REGENERATIVE SOLUTION
COWELL®
104 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 105
COWELLMEDI HISTORY
Shoulder Abutment Shoulder Impression Cap
D Type Crown Hex Hex2.7 Hex3.4
Diameter 8 9
Hex Hex2.7 Hex3.4 Height
2 Pieces L H
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] 8 IICR001 IICW001
Crown
3 SAC434 SAC435 SAC437 SAC534 SAC535 SAC537
Hex
REID
4 SAC444 SAC445 SAC447 SAC544 SAC545 SAC547
Platform
Type Bridge
Hex Hex2.7 Hex3.4
D
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
L Diameter Ø4.8 Ø5.9
2 Pieces
Length
C Cuff 4 5.5 7 4 5.5 7
REGENERATIVE SOLUTION
COWELL®
106 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 107
COWELLMEDI HISTORY
Ball Abutment
Outer Cap Block-out Spacer
Cuff
Length
Ø5.0
4
Ø6.0
4
Component Selection Guide for Ball Abutment 1 EBAT411R EBAT511R
2 EBAT412R EBAT512R
Red : 10N Orange : 15N Green : 20N 3 EBAT413R EBAT513R
Ball Inner Cap 4 EBAT414R EBAT514R
D > Packing unit : 1 Ball Abutment + 3 Inner Caps (1 per each color) + 1 Block-out Spacer + 1 Outer Cap.
> For Implant Supported Over-denture Prosthesis.
REID
L > Tightened with the Ball Driver and Torque Wrench.
C
> Tightening torque force : 30 N.cm.
> Direct impression.
Ball Outer Cap Block-out Spacer
Ball Abutment
Ball Analog
Ball Abutment
Healing
Fixture Cover Screw Abutment I&R Driver Height 100
KBIR01
REGENERATIVE SOLUTION
For Removal For Insertion
COWELL®
> Packing unit : 1 I&R Driver.
> Used to insert and remove the Inner Caps into and out of the Outer Cap.
REID
COWELL® IMPLANT SYSTEM
Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF
'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM
Parallel Pin Parallel Pin Ø2.2 X 8 Ø3.5 X 8 Ø4.0 X 8 Ø4.5 X 8 Ø5.0 X 8 Ø6.0 X 8 Parallel Pin Parallel Pin Ø2.2 X 8 Ø3.5 X 8 Ø4.0 X 8 Ø4.5 X 8 Ø5.0 X 8 Ø6.0 X 8
KPP002 KPP002 KPSD2208 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008 KPP002 KPP002 KPSD2208 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008
1.2 Hex Driver L 1.2 Hex Driver XL Ø2.2 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Ø6.0 X 10 1.2 Hex Driver L 1.2 Hex Driver XL Ø2.2 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Ø6.0 X 10
KHD1221 KHD1227 KPSD2210 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010 KHD1221 KHD1227 KPSD2210 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010
M. Fixture Driver. S R. Fixture Driver. L Ø2.2 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14 M. Fixture Driver. S R. Fixture Driver. S Ø2.2 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14
2KMMS01S 2KHDS01L KPSD2214 2KTD3714 2KTD4014 2KTD4514 2KTD5014 KMMI01S KHDI01S KPSD2214 2KTD3714 2KTD4014 2KTD4514 2KTD5014
M. Fixture Driver. L R. Fixture Driver. XL Drill Extension Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø6.0 Countersink M. Fixture Driver. L R. Fixture Driver. L Drill Extension Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø6.0 Countersink
2KMMS01L 2KHDS01X KDE002 4KCS35 4KCS40 4KCS45 4KCS50 4KCS60 KMMI01L KHDI01L KDE002 4KCS35 4KCS40 4KCS45 4KCS50 4KCS60
REGENERATIVE SOLUTION
COWELL®
Torque Wrench Depth Gauge Torque Wrench Depth Gauge
A common tool for A common tool for
KTW001 KDG004 Sub. / Int. / Ext. An exclusive tool by type KTW001 KDG001 Sub. / Int. / Ext. An exclusive tool by type
01
EXT. > For the selection and use guide of the components for the Sub. Int. & Ext. Full Surgical Kit, refer to pages 113 to 119. SUB. INT. EXT.
HEXAGON OCTAGON HEXAGON
HEXAGON > For the INNO External Implant System (Ext.). SYSTEM SYSTEM SYSTEM
SYSTEM > All components are for Sub. / Int. / Ext. except for the Fixture Drivers and the Multi Countersink used for Ext. exclusively.
Drill / Surgical Tool
REID
Point Drill
> Primarily used for marking the implant recipient site and to determine spacing.
> The point drill has a unique pointed tip, making this an excellent drill for starting the osteotomy
L
7 through the hard cortical plate.
31.8 3.5
Length 15
KPD01S
Length 8 9 11 13 15 17&19
1.2 Hex Driver L 1.2 Hex Driver XL Ø2.2 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Ø6.0 X 10 KPSD2207 KPSD2208 KPSD2210 KPSD2212 KPSD2214 KPSD2218
KHD1221 KHD1227 KPSD2210 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010 *Extra product
M. Mount Driver. L R. Mount Driver. L Ø2.2 X 12 Ø3.5 X 12 Ø4.0 X 12 Ø4.5 X 12 Ø5.0 X 12 Ø6.0 X 12
KMMD06L KRMD19L KPSD2212 2KTD3712 2KTD4012 2KTD4512 2KTD5012 2KTD6012
&YU'JYUVSF%SJWFS
%SJMM Stopper with irrigation groove.
%SJMM
M. Fixture Driver. S R. Fixture Driver. L Ø2.2 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14
4.9
KMME01S KHDE01L KPSD2214 2KTD3714 2KTD4014 2KTD4514 2KTD5014 Ø4.9 Crestal cutter – Flattening the slopped and sharp crestal ridge which
2.5 make crestal bone surround around the whole fixture platform.
3.3
1.5 2.8
Ø3.3/2.8 Pilot cutter – Stepped hole guiding the pathway of Ø3.5 / Ø4.0 /Ø4.5
fixture's final drill.
M. Fixture Driver. S R. Fixture Driver. L Drill Extension Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø6.0 Countersink
KMME02S KHDE02L KDE002 4KCS35 4KCS40 4KCS45 4KCS50 4KCS60
REGENERATIVE SOLUTION
Ø2.2 Path cutter – Determining the orientation of fixture installation.
COWELL®
Torque Wrench Depth Gauge
Multi Countersink the Final Drills. The Final Drill is inserted a
A common tool for half into the Initial Drill's hole without drilling.
4KCS01 KTW001 KDG001 Sub. / Int. / Ext. An exclusive tool by type
REID
15 2KTD3714 2KTD4014 2KTD4514 2KTD5014
18.5 4 2 17
17&19 2KTD3718 2KTD4018 2KTD4518
*Extra product
D
> Preventing compressive necrosis of dense cortical bone. Length 21 After Ø2.2 After Ø3.5
initial drilling. final drilling.
28.6 KPP002
Fixture Dia. Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø6.0
Diameter Ø3.7 Ø4.2 Ø4.6 Ø5.1 Ø6.0
4KCS35 4KCS40 4KCS45 4KCS50 4KCS60
1mm
1mm
REGENERATIVE SOLUTION
COWELL®
114 SURGICAL KIT SURGICAL KIT 115
COWELLMEDI HISTORY
Mount Driver > Used to install Pre-Mount type fixtures. Fixture Driver > Used to install No-Mount type fixtures.
Type Machine
Type Sub.
L Length Machine System
Length Sub. Int. Ext.(Hex 2.7) Ext.(Hex 3.4)
20.5(Short) KMMD06S
Int.
28.1 / 26.3 / 26.4 (Short) 2KMMS01S KMMI01S KMME01S KMME02S
26.3(Long) KMMD06L
33.3 / 30.5 / 31.4 (Long) 2KMMS01L KMMI01L KMME01L
32.3(X-Long) KMMD12X
Ext. 40.3 / 35.5 / 36.4 (X-Long) 2KMMS01X KMMI01X KMME01X
*Extra product
*Extra product
Type Ratchet
Sub. System
Length Sub. Int. Ext.(Hex 2.7) Ext.(Hex 3.4)
REID
L Type
Length Ratchet 20.7 / 19.5 / 19.9 (Short) 2KHDS01S KHDI01S KHDE01S
Int.
12(Short) KRMD12S 25.7 / 24.5 / 24.9 (Long) 2KHDS01L KHDI01L KHDE01L KHDE02L
19(Long) KRMD19L Ext. 30.7 / 29.5 / 29.9 (X-Long) 2KHDS01X KHDI01X KHDE01X
*Extra product *Extra product
4
3
2 4
1 3
2
1
H Type Ratchet
Hex
Length Hex 0.9 Hex 1.2
12(X-Short) - KHD1212
17(Short) KHD0915 KHD1215
23(Long) KHD0921 KHD1221
29(X-Long) KHD0927 KHD1227 Depth Gauge > Measuring the drill depth with scaled rod.
> Measuring the 5mm space between adjacent fixtures with flat end of the other side.
Code KDG001
> One side of the Depth Gauge measures the drilling depth and the other side
measures the gingival height from the top of the implant.
REGENERATIVE SOLUTION
Code KDG004 ⲼExclusive for Sub.
COWELL®
116 SURGICAL KIT SURGICAL KIT 117
COWELLMEDI HISTORY
02
Sloped edentulous ridge adjacent of tooth > Crestal cutter of the Initial Drill and Final Drill.
> Longer drills than fixture’s length.
> Minimal drill frequency with the Point Drill, Ø2.2 Initial Drill and Final Drills > Length Marking
(Ø3.5, Ø4.0 and Ø4.5 Fixtures).
Ø2.2 Initial Drill Final Drill 12mm Drill 10mm Fixture
Crestal flatting Longer Final Drill
REID
Wide extraction socket
> Absence of the cortical bone & spongy bone.
> Narrower diameter than the fixture’s diameter.
Ø4.5
> Ø5.0 fixture : a series of the Point Drill, Ø2.2 Initial Drill, Ø4.0 Final Drill and Ø5.0 Final Drill.
> Ø6.0 fixture : a series of the Point Drill, Ø2.2 Initial Drill, Ø4.0 Final Drill, Ø5.0 Final Drill and Ø6.0 Final Drill.
0.5mm deeper level.
Level Crestal level 0.5mm Deeper Level
Debriment with without with without
Ø4.5 Fixture 4.4 10.2 - 12.9
REGENERATIVE SOLUTION
Ø5.0 Fixture 11.6 19.9 14.1 24.5
Ø4.5 Drill Ø5.0 Fixture
COWELL®
ⲼThe Countersink and Tap Drill are used in hard bone quality.
*Extra product
REID
* While the 2.2 Initial Drill is used at 1,000 rpm with irrigation,
the Final Drills from the 3.5 to 5.0 should be used at 50 rpm without irrigation.
Drill
Ø3.5
Point Ø2.2 Ø3.5 Countersink
Point Drill Ø2.2 Initial Drill Ø3.5 Final Drill Ø4.0 Final Drill Ø4.5 Final Drill Ø5.0 Final Drill
KPD01S 2KTD22 2KTD35 2KTD40 2KTD45 2KTD50 Ø4.0
Point Ø2.2 Ø4.0 Countersink
Stopper Countersink
Normal Bone Hard Bone
Ø5.0
REGENERATIVE SOLUTION
Normal Bone Hard Bone
COWELL®
Torque Wrench
Drill Extension M. Fixture Driver L R. Fixture Driver L 1.2 Hex Driver L 1.2 Hex Driver XL
KDE002 2KMMS01L 2KHDS01L KHD1221 KHD1227 KTW001
REID
Drilling Sequence
Normal Bone Hard Bone
Ø4.0
Point Ø2.0 Ø4.0 Countersink
Drill
Ø4.5
Point Ø2.0 Ø4.0 Ø4.5 Countersink
Point Drill Ø2.0 Step Drill Ø4.0 Step Drill Ø4.5 Step Drill Ø5.0 Step Drill Ø5.5 Step Drill Ø6.0 Step Drill
Normal Bone Hard Bone
KPD01S KSSD2004 KSSD4004 KSSD4504 KSSD5004 KSSD5504 KSSD6004
Stopper Countersink
Ø5.0
Point Ø2.0 Ø4.0 Ø4.5 Ø5.0 Countersink
Torque Wrench
M. Mount Driver. L R. Mount Driver. L 1.2 Hex Driver L
REGENERATIVE SOLUTION
KMMD06L KRMD19L KHD1221 KTW001
Ø6.0 Point Ø2.0 Ø4.0 Ø4.5 Ø5.0 Ø5.5 Ø6.0 Countersink
COWELL®
A common tool for An exclusive tool for
the INNO Surgical Kits. the Short Implants.
2.8
Machine
arrow K I T Ratchet X-Long Machine X-Long
12
10
Fixture Driver
REID
Drill Ø 3.3
Stopper Fixture
Mount Driver
8
Ø 3.1
Fixture
Drill
Parallel Pin
21
Code KPP003
Stopper Countersink
Normal Bone
Drilling Sequence Hard Bone
Ø3.1
Extension & Driver Point Ø2.2 Ø2.6 Ø3.1 Ø3.1
Countersink Normal Bone
Hard Bone
Depth Gauge
KDG001
Torque Wrench
Fixture Driver(Ratchet) Fixture Driver(Machine) Parallel Pin 1.2 Hex Driver L
REGENERATIVE SOLUTION
KHDS01XN KMMS01XN KPP003 KHD1221 KTW001
Ø3.3
Point Ø2.2 Ø2.6 Ø3.3 Ø3.3
Countersink
COWELL®
124 SURGICAL KIT SURGICAL KIT 125
COWELL® PROSTHETIC KIT [KPA003]
SUB.
> For the INNO Submerged Implant System.
HEXAGON
SYSTEM > Try-in Kit for determining abutment specifications.
Surgical kit
Abutment Gauge > Measuring of the diameter, cuff length and angulation of abutment.
7
5.5
4
4
2 3
1
Cuff 2 Cuff 4 15° / Cuff 2 15° / Cuff 4 25° / Cuff 2 25° / Cuff 4
2SAG002 2SAG004 2SAG152 2SAG154 2SAG252 2SAG254
Abutment Driver > Used in the Shoulder, Solid, Absolute, and Straight Abutment placement.
Shoulder Ø4.0 Shoulder Ø5.0 Hex 1.2 Ratchet Hex 1.2 Machine Tissue Punch
KRR19L KRW19L KHD1221 KMD12L KTP001 2 Pieces
Trephine soft tissue over
the Cover Screw of fixture.
REID
2
Implant
Top Anti-Rotation Square
> Promotes firm attachment to prosthetics.
> Direct impression is recommended when
2
modified/altered.
Diameter Diameter
Ø2.5 Ø3.0
Cuff Cuff
Cutting Groove > Packing unit : 1 Fixture. > Packing unit : 1 Fixture.
> Two cutting grooves at 5mm, 7mm facilitates > Abutment level impression. > Abutment level impression.
alteration of height.
Cuff
Length
Lab Analog
Impression Coping Lab Analog
Diameter Diameter
Length Ø4.0
Length
7mm AMCC001
REGENERATIVE SOLUTION
9mm AMCC002
COWELL®
> Packing unit : 1 Protection Cap.
REID
Implant
Diameter Diameter
Ø2.5 Ø3.0
Cuff Cuff
4.2 Easy delivery using the ball type drivers Length
2.0mm 4.0mm Length
2.0mm 4.0mm
Length
Ball Inner Cap
Block-out Ball Inner Cap
Spacer BATC003I
> Packing unit : 2 Block-out Spacers + 6 Inner Caps (2 per each color).
> Retention force : Red 10N, Orange 15N & Green 20N.
Red : 10N Orange : 15N Green : 20N
Impression Coping
> Packing unit : 1 Impression Coping.
> Used for impression taking of the ball post.
Lab Analog
REGENERATIVE SOLUTION
Impression Coping Lab Analog
AMBI001 AMBL001 > Packing unit : 1 Lab Analog.
> Replacement of the ball post shape in working model.
COWELL®
130 Mini Plus® Implant Mini Plus® Implant 131
COWELLMEDI HISTORY
Tissue Punch
SURGICAL KIT [KMA003] KTP16
*Extra product
Ø2.35(Ø2.0 Implant)
REID
Point Drill
Multi Gauge *Extra product > Allows precise measurement of drilling depth and path.
36.8mm
KPD03L Length
30
20
10mm 8mm 5mm
(Ø3.0, Ø3.3 Implant) (Ø2.5 Implant) (Ø2.0 Implant) KDGP13 Ø1.3
Driver Ø3.0
Cement Type Ball Type
Point Drill Ø2.3 Twist Drill Ø3.0 Implant (12mm)
REGENERATIVE SOLUTION
Machine KMDC31L Machine KMDB27L
Soft Bone Soft Bone
D3 / D4 D3 / D4
COWELL®
Ratchet KRDC19L Ratchet KRDB19L
ⲼIn case of D4 bone quality, make proper adjustment in drilling. Due to narrow diameter,
the Mini Plus® Implants have self-tapping characteristic.
Exclusive for the INNO Submerged and Universal to any implant system.
Submerged Narrow Implant System.
COWELLMEDI HISTORY
InnoFit® Lodestar Plus Kit [KLSP001]
>G A total guided surgery solution applicable to various types of clinical cases.
>G Exclusive for the INNO Submerged and Submerged Narrow Implant System.
REID
Pilot Drill Pilot Drill Pilot Drill Pilot Drill Pilot Drill
(Ø3.1/3.3) (Ø3.5) (Ø4.0) (Ø4.5) (Ø5.0) Implant Adapter
KLPPD3307 KLPPD3308 KLPPD3310 KLPPD3312 KLPPD3314 KLPPD3507 KLPPD3508 KLPPD3510 KLPPD3512 KLPPD3514 KLPPD4007 KLPPD4008 KLPPD4010 KLPPD4012 KLPPD4014 KLPPD4507 KLPPD4508 KLPPD4510 KLPPD4512 KLPPD4514 KLPPD5007 KLPPD5008 KLPPD5010 KLPPD5012 KLPPD5014 KLPF01R KLPF02R KLPF01N KLPF02N
Torque Wrench
KTW001LP
12L
12L
08S
08S
REGENERATIVE SOLUTION
COWELL®
Hex Driver V Anchor Countersink Adapter Extension Abutment Profile
KLPHD1214 KLPHD1220 KLPVA00I KLPVA00B KLPCS31 KLPCS33 KLPCS35 KLPCS40 KLPCS45 KLPCS50 KLPRE08S KLPRE12L KLPME08S KLPME12L KLPAP10 KLPAP12 KLPAP14
136 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 137
COWELLMEDI HISTORY
Workflow Preparation before Operation
REID
Clinic
!
"#
$ %
Partially digital &
' (
procedure Model
Patient CT Scanning Scanning
+)%
%
(
%
%
, !
Dental
Lab -
(
+
%$
)
Fabrication - Abutment & Implant simulation &
.
(
)
(
3D Printing & CAD/CAM crown design surgical guide template $%
/
Dental
Clinic
REGENERATIVE SOLUTION
COWELL®
138 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 139
COWELLMEDI HISTORY
Comprehension and Usage of Offset Tissue Punch > Used for soft tissue elimination (the gingiva in the position where the implant is to be
placed can be incised in a circular shape).
> The basic length from the fixture platform to the top of the Sleeve is 9mm. > Hemostatic effect, small scar, fast wound healing affect is occurred after the operation due
> In case that gingival is thick or fixture needs to be placed deeper due to low bone density, use the Sleeve 2 or 4mm upright to the top. to small diameter of tissue punch.
> The higher offset value, the less accurate it will be, so use 9mm if possible. > Able to apply offset (9mm, 11mm, 13mm).
> 50 rpm without irrigation.
27.1
Double blade
The internal cutting edge of the Tissue Punch cuts the gingival into small pieces so that those
13 can be removed by suction without extra work.
REID
Ø3.5
Ø5.2
KLPTP01
* Caution The Tissue Punch must be kept clean. Otherwise, it may cause rust or blade damage due to
Pilot Drill Countersink Implant Adapter
residual gingival pieces or others in the Tissue Punch after the operation
Bone Flattening Drill > Flattens the bone level of operation site.
> Inclined bone level may glide the Drill and cannot drill as planned.
> Eliminate the soft tissue after using the Tissue Punch.
> The point in the middle of the Drill guides the position of the Drill and
helps to drill in an accurate site.
> Able to apply offset (9mm, 11mm, 13mm).
> 400 rpm without irrigation / 800 rpm with irrigation.
Initial Drill
Point
6 Creates the hole on the bone surface so that the axis
* Caution Selection of the Drill according to the Sleeve
REGENERATIVE SOLUTION
offset (In case of placing 8mm Fixture) of the next step Drill is not moved and it guides the Drill
Please be noted that actual depth of drilling is 1mm deeper
: In case of offset 13mm(4mm) – Select 12mm Drill. position by preventing slip even at the inclined bone level.
than marks of the Drill. Ø2.15
COWELL®
Ex) 4.0 X 8mm Drill - Drilling depth : 9mm. Ø2.8
KLPID06S
140 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 141
COWELLMEDI HISTORY
Pilot Drill > Low speed, 50 rpm without irrigation / 50 N.cm
H : 32 H : 33 H : 35 H : 37 H : 39
H : 32 H : 33 H : 35 H : 37 H : 39
REID
4
4
9
9
4.3
3.2
3.9
2.8 8
8 9
9 3.5 10
2.15 10 11
11 12
12 13
13 14
14 15
15
H : 32 H : 33 H : 35 H : 37 H : 39 H : 32 H : 33 H : 35 H : 37 H : 39
3.5 4.9
3.2 4.3
8 8
9 10 3.9 9 10
2.8
11 11
12 12
13 13
14 14
15 15
H : 32 H : 33 H : 35 H : 37 H : 39
4
9
3.9
3.5
REGENERATIVE SOLUTION
8
9 10
3.2
11
12
13
COWELL®
14
15
142 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 143
COWELLMEDI HISTORY
Countersink > Expand the cortical bone in D1/D2 bone to prevent excessive implantation of the fixture. Fixture Driver - Molar > Use in case the Implant Adapter can not be used due to small size of opened mouth or
> Able to apply offset (9mm, 11mm, 13mm). narrow gap between antagonist tooth.
> 50 rpm without irrigation. > After implanting 4~5mm, change to the Implant Adapter to complete placement.
13mm
11mm
REID
9mm 4~5
08S Adapter
Extension
Implant
Adapter
13mm
11mm
12L
12L
12 12 9mm
08S
08S
Implant Adapter
KLPAP10 KLPAP12 KLPAP14
> Move fixture to the Sleeve to implant safely. Before use After use
> Match the depth of laser marks of the Sleeve offset and Implant Adapter.
> When implanting the fixture, the direction of the Implant Adapter and directional identification Groove for Removal
O-ring Color
Regular - Red
Narrow - Yellow
13mm
11mm Hex-directional
9mm
identification
groove.
REGENERATIVE SOLUTION
Regular-Stop Regular-No Stop Narrow-Stop Narrow-No Stop
COWELL®
KLPF01R KLPF02R KLPF01N KLPF02N
144 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 145
COWELLMEDI HISTORY
V Anchor - Fix Fixture > Connect the 1.2 Hex Driver to implanted fixture to prevent the movement of the Torque Wrench(Square) > Use to implant the fixture (Connect to the Implant Adapter).
surgical guide template in cases as edentulous. > Use after connecting to the 1.2 Hex Driver.
> Use after connecting to the V Anchor (Fix Bone).
13mm
11mm
9mm Torque Wrench KTW001LP
REID
KLPVA00I KLPVA02I KLPVA04I
Extra Extra * Caution
- Connect by aligning to the Sleeve offset of connected fixture.
- Basic composition of the Sleeve offset 9mm (11, 13mm extra).
V Anchor - Fix Bone > Fix the V Anchor using the Torque Wrench in the hole made after initial drilling to Extra
3
13mm
11mm Ø5
9mm
Ratchet 1.2 Hex Driver > Use in case of connecting the Cover Screw or Healing Abutment.
14
KLPHD1214 KLPHD1220
REGENERATIVE SOLUTION
COWELL®
146 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 147
COWELLMEDI HISTORY
Drill Protocol
* Drilling method - Make sure with drilling in a desired direction without a change in path through the primary drill contact (A) with the hole created
by the previous drilling and the secondary contact (B) with the sleeve.
- Create the hole using the initial drill and insert the next drill into the hole made during the previous step and drill after achieving
REID
Drill Protocol (7~10mm) the drill and sleeve contact (A&B).
INNO Sub Fixture Ø5 x 10mm - If drilling only with the sleeve contact (B) without the drill contact (A), the path may not be correct.
Bone
Tissue Punch Flattening Initial Ø3.3 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Countersink Abutment
Drill Profile
A A
Hard Bone
A &TKNNEQPVCEV B 5NGGXGEQPVCEV
Bone
Tissue Punch Flattening Initial Ø3.3 X 10 Ø3.3 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14 Countersink Abutment
Drill Profile
REGENERATIVE SOLUTION
COWELL®
148 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 149
COWELLMEDI HISTORY
InnoFit® Lodestar Kit [KLS001]
>G A cost-effective guided surgery solution applicable to various types of clinical cases.
>G Universal to any implant system.
Ø2.0 X 7 Ø2.0 X 8 Ø2.0 X 10 Ø2.0 X 12 Ø2.0 X 14 Ø2.7 X 7 Ø2.7 X 8 Ø2.7 X 10 Ø2.7 X 12 Ø2.7 X 14 Ø3.4 X 7 Ø3.4 X 8 Ø3.4 X 10 Ø3.4 X 12 Ø3.4 X 14 Ø4.2 X 7 Ø4.2 X 8 Ø4.2 X 10 Ø4.2 X 12 Ø4.2 X 14
REID
Pilot Drill(Ø2.0) Pilot Drill(Ø2.7) Pilot Drill(Ø3.4) Pilot Drill(Ø4.2)
Initial Drill
KLSID18 KLSID18L
REGENERATIVE SOLUTION
COWELL®
Abut. Profile Drill Drill Extension
KLSPD10 KLSPD12S KLSPD14 KDE002
14.1
REID
10
10
12.1 10
10 10 23
19 21
16 17
9
6 7 11 13
Ø4
Ø4.45
The internal cutting edge of the Tissue Punch cuts the
Initial Drill > The Drill combined with Bone Flattening Drill and Point Drill which no separate Bone Flattening Drill is
10
10
10
10
10 25
23
21
17 19
15
11 13
14 12 10 Pilot Drill 17mm(7mm) Pilot Drill 19mm(9mm) Pilot Drill 21mm(11mm) Pilot Drill 23mm(13mm) Pilot Drill 25mm(15mm)
10
Bone Flattening
KLSPD2707 KLSPD2708 KLSPD2710 KLSPD2712 KLSPD2714
Flattens uneven
Point surface of alveolar crest.
6 6
KLSPD3407 KLSPD3408 KLSPD3410 KLSPD3412 KLSPD3414
Creates the hole on the bone surface
so that the axis of the next step Drill is KLSPD4207 KLSPD4208 KLSPD4210 KLSPD4212 KLSPD4214
not moved and it guides the Drill position
by preventing slip even at the inclined bone level.
KLSID18 KLSID18L
REGENERATIVE SOLUTION
COWELL®
152 InnoFit® Lodestar Kit InnoFit® Lodestar Kit 153
COWELLMEDI HISTORY
Abutment Profile > Used for elimination of the alveolar bone that interferes with * Offset length setting
the accurate connection of abutment.
- The basic length from the fixture platform to the top of the Sleeve is 10mm.
- In case that gingival is thick or fixture needs to be placed deeper due to low bone density,
use the Sleeve 2 or 4mm upright to the top.
- The higher offset value, the less accurate it will be, so use 10mm if possible.
REID
5.2
14mm
16
12mm
10mm
Ø4.5
5
15
* Remove residual bone by rotating
and drilling 360° along the inside
9.5 3.2
Ø4.3
Ø1.3
Anchor Drill Anchor Screw Anchor Driver Anchor Driver
REGENERATIVE SOLUTION
COWELL®
154 InnoFit® Lodestar Kit InnoFit® Lodestar Kit 155
COWELLMEDI HISTORY
Optional > These products are optional as extra ones which are not included in the kit. Sleeve Extra
5.3 5.3
Ø4.5 Ø4.5
1mm
Guide Reamer Extra
Ø4.3
4mm
Used for precise contact of Drill and Sleeve (Sleeve / Non Sleeve). 90˚
Use the 4.5mm Guide Reamer for Non Sleeve, and the 5.3 Guide Reamer for Sleeve (800 rpm without irrigation).
REID
Ø5.3 Ø5.3
Closed Sleeve Open Sleeve
Guide Reamer Guide Reamer
(Non Sleeve) (Sleeve) KLSS01 KLSS02
KLSRD45 KLSRD53
* Packing Unit : 5 Sleeves * Packing Unit : 5 Sleeves Hex-directional
15mm 15mm identification groove.
31mm 31mm
Ⱍ
19 19 19
Ⱍ 17 17
17
10mm 10mm
17mm 19mm
REGENERATIVE SOLUTION
COWELL®
16mm Fixture 18mm Fixture
Drilling Sequence
e.g.) 3.4 X 14mm Drilling Sequence
Final drill of Countersink Tap Drill Placement
*OJUJBM Ⱍ9 Ⱍ9 Ⱍ9 Ⱍ9 each system
Reamer
*OJUJBM Final drill of Countersink Tap Drill Placement
(Ø4.5) each system
REID
Offset
2
2
10
*Extra With the guided template mounted After removal of the guided template
B B
Offset
2
2 A A
10
*Extra
A &TKNN%QPVCEV B 5NGGXG%QPVCEV
REGENERATIVE SOLUTION
COWELL®
X
158 InnoFit® Lodestar Kit InnoFit® Lodestar Kit 159
COWELLMEDI HISTORY
Component selection guide for Intra-oral scanning Component selection guide for • Model-scanning
procedure • Handwork procedure
the Sub. SFIT Ti-Base System the Sub. SFIT Ti-Base System
SUB. SUB.
HEXAGON HEXAGON
SYSTEM SYSTEM
REID
Prosthesis
Prosthesis
Digital Analog
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short
REGENERATIVE SOLUTION
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short
COWELL®
160 SFIT Ti-Base System : Sub. SFIT Ti-Base SFIT Ti-Base System : Sub. SFIT Ti-Base 161
COWELLMEDI HISTORY
SFIT S Ti-Base 1.2 Hex SFIT S Ti-Base Screw SFIT Ti-Base Cuff 1 2 3 4
Height 10.6 11.6 12.6 13.6
D 2.3 1.2 Hex Diameter
Type Hex N-Hex
L Ø2.3 2SSFS10S35 2SSFS20S35 2SSFS30S35 2SSFS40S35
Diameter Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5 2.3
C
Length > Packing unit: 1 SFIT S Ti-Base Screw.
Cuff 3.6 3.6 3.6 3.6 3.6 3.6
> Used to connect the SFIT S Ti-Base.
1 2SSFH38135 2SSFH45135 2SSFH55135 2SSFN38135 2SSFN45135 2SSFN55135 H
Ø3.8 Ø4.5 Ø5.5 2SSFS10S35: SFIT S Ti-Base with Cuff 1, 2SSFS20S35: SFIT S Ti-Base with Cuff 2,
2 2SSFH38235 2SSFH45235 2SSFH55235 2SSFN38235 2SSFN45235 2SSFN55235 2SSFS30S35: SFIT S Ti-Base with Cuff 3, 2SSFS40S35: SFIT S Ti-Base with Cuff 4.
3 2SSFH38335 2SSFH45335 2SSFH55335 2SSFN38335 2SSFN45335 2SSFN55335 > Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
Hex 4 2SSFH38435 2SSFH45435 2SSFH55435 2SSFN38435 2SSFN45435 2SSFN55435
REID
L
> Packing unit: 1 SFIT S Ti-Base + 1 SFIT S Ti-Base Screw.
> For Screw Retained Prosthesis with straight screw channel.
C
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Connected with the SFIT S Ti-Base Screw.
Ø3.8 Ø4.5 Ø5.5
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
> Use the SFIT Scanbody for digital workflow.
N-Hex > Fixture level impression.
L
> Packing unit: 1 SFIT A Ti-Base + 1 SFIT A Ti-Base Screw.
> For Screw Retained Prosthesis with angulated screw channel.
C
> Gold color for more translucent restoration.
Angulated Screw > Library available for EXOCAD®, 3Shape® & others. Scanbody Type Hex
Ratchet Driver
> Connected with the SFIT A Ti-Base Screw. D
Ø3.8 Ø4.5 Ø5.5
REGENERATIVE SOLUTION
COWELL®
162 SFIT Ti-Base System : Sub. SFIT Ti-Base SFIT Ti-Base System : Sub. SFIT Ti-Base 163
COWELLMEDI HISTORY
Bite Impression Coping Digital Analog
Type Hex(Short) Hex(Long) Hex(X-Long)
D D Diameter
Diameter Ø4.5 Ø4.5 Ø4.5 Height Ø3.9
L Cuff 12 2SDR001
Length 2 4 6
H
4.0 2SBIC45S 2SBIC45L 2SBIC45X > Packing unit: 1 Digital Analog.
C
> Analog of fixture for working cast.
> Packing unit: 1 Bite Impression Coping + 1 Guide Guide Pin (inbuilt). > Used for both 3D printed model (RP) and stone model.
> Designed to simultaneously take bite and impression.
> For closed tray impression (bite impression).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
(Short) (Long) (X-Long)
> Tightening torque force: 12~15 N.cm.
REID
Hex
SFIT Ti-Base Setting Screw
Diameter
Height Ø1.95
1.2 Hex
8.2 2SSFSS100
1.95
> Packing unit: 5 SFIT Ti-Base Setting Screws.
> Used to screw the SFIT S or A Ti-Base into the Digital Analog or the Fixture when revising such prosthetic
Pick-up Impression Coping Type Hex N-Hex
H adaptions as shape, contact surface, occlusion and margin without giving a force to the head of the
SFIT Ti-Base S or A Ti-Base to spread and fit in the inner space of the prosthesis.
C > Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (2SISR001SS / 2SISR001SL).
> For open tray impression.
> Connected with the Guide Pin. SFIT Titanium Cylinder
(Short) (Short) (Long) (Short) (Short) (Long) > Tightened with the 1.2 Hex Driver and Torque Wrench. Type Crown Bridge
SFIT Ti-Base
2 Pieces Diameter Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5
H Diameter
Height Ø4.1 Ø4.8 Ø5.8 Ø4.1 Ø4.8 Ø5.8
Hex N-Hex
7 2SSFTC3835H 2SSFTC4535H 2SSFTC5535H 2SSFTC3835N 2SSFTC4535N 2SSFTC5535N
REGENERATIVE SOLUTION
> Tightening torque force: 30 N.cm.
Hex N-Hex
COWELL®
164 SFIT Ti-Base System : Sub. SFIT Ti-Base SFIT Ti-Base System : Sub. SFIT Ti-Base 165
COWELLMEDI HISTORY
Component selection guide for Intra-oral scanning Component selection guide for • Model-scanning
procedure • Handwork procedure
the Sub. SFIT Absolute Ti-Base System the Sub. SFIT Absolute Ti-Base System
SUB. SUB.
HEXAGON HEXAGON
SYSTEM SYSTEM
REID
Crown
Crown
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short
REGENERATIVE SOLUTION
COWELL®
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short
166 SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base 167
COWELLMEDI HISTORY
SFIT Absolute S Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5 SFIT Absolute S Ti-Base Screw Diameter
Height Ø2.3
D Length
1.2 Hex Cuff 3.6 3.6 3.6 1.2 Hex 4.1 2SSFS100S
L
1 2SSF38135 2SSF45135 2SSF55135
C 2.3
2.3 > Packing unit: 1 SFIT Absolute S Ti-Base Screw.
2 2SSF38235 2SSF45235 2SSF55235
H
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
3 2SSF38335 2SSF45335 2SSF55335
Ø3.8 Ø4.5 Ø5.5 4 2SSF38435 2SSF45435 2SSF55435
> Packing unit: 1 SFIT Absolute S Ti-Base + 1 SFIT Absolute S Ti-Base Screw.
> For Screw Retained Prosthesis with straight screw channel.
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
REID
> Integrated with the Screw and Ti-Base (solid screw).
> Tightened with the 1.2 Hex Ratchet Driver or Absolute Ratchet Driver and Torque Wrench.
> Prosthesis is connected to the SFIT Absolute S Ti-Base by the SFIT Absolute S Ti-Base Screw using
the 1.2 Hex Ratchet Driver.
> Tightening torque force: 30 N.cm.
> Use the SFIT Absolute Scanbody for digital flow.
> Abutment level impression.
Angulated Screw
Ratchet Driver > Packing unit: 1 SFIT Absolute A Ti-Base + 1 SFIT Absolute A Ti-Base Screw.
> For Screw Retained Prosthesis with angulated screw channel.
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Integrated with the Screw and Ti-Base (solid screw).
> Tightened with the 1.2 Hex Ratchet Driver or Absolute Ratchet Driver and Torque Wrench.
> Prosthesis is connected to the SFIT Absolute A Ti-Base by the SFIT Absolute A Ti-Base Screw using
the Angulated Screw Ratchet Driver.
> Tightening torque force: 30 N.cm.
SFIT Absolute Ratchet Driver
Type Crown
> Use the SFIT Absolute Scanbody for digital flow. H
Height
Type Ratchet 26 KSFR3819L KSFR4519L
24(Short) KRBUD15
29(Long) KRBUD20 > Packing unit: 1 SFIT Absolute Ratchet Driver.
H > Used to install and uninstall the SFIT Absolute S & A Ti-Base in case of internal slip.
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and
the dedicated Stargrip Abutment Screw. > KSFR3812S & KSFR3819L for the SFIT Absolute S & A Ti-Base with Ø3.8 and
> Tightening torque force : 30 N.cm (50 N.cm Max.). KSFR4512S & KSFR4519L for the SFIT Absolute S & A Ti-Base with Ø4.5 and Ø5.5.
REGENERATIVE SOLUTION
COWELL®
168 SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base 169
COWELLMEDI HISTORY
SFIT Absolute Scanbody SFIT Absolute Digital Analog SFIT Absolute
Type Crown Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5
D
SFIT Absolute Diameter
Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5 Length Ø3.8 Ø4.5 Ø5.5
L
Diameter
H Height Ø4.25 Ø4.95 Ø5.85 3.6 2SSFLA3835 2SSFLA4535 2SSFLA5535
4.1 2SSFSB3835H 2SSFSB4535H 2SSFSB5535H
D > Packing unit: 1 SFIT Absolute Digital Analog.
> Packing unit: 1 SFIT Absolute Scanbody. > Replacement of the SFIT Absolute S or A Ti-Base shape in working cast.
> For both intra-oral scanning and model-scanning. > Used for both 3D printed model (RP) and stone model.
Crown > Made of 100% titanium alloy with a special coating applied. > Select according to dimension of the SFIT Absolute S or A Ti-Base.
> No need to spray.
> For the connection to the SFIT Absolute S Ti-Base, use the SFIT Absolute S Ti-Base Screw with the
1.2 Hex Ratchet Driver and Torque Wrench.
> For the connection to the SFIT Absolute A Ti-Base, use the SFIT Absolute A Ti-Base Screw with the
REID
Angulated Screw Ratchet Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.
> Packing unit: 1 SFIT Absolute Transfer Post + 1 Guide Pin. D > Packing unit: 1 1 SFIT Meta G UCLA Cylinder.
> For closed tray impression. > Used over both SFIT S or A Ti-Base and SFIT Absolute S or A Ti-Base.
Crown Bridge > Also used as a scanbody for intra-oral scanning and model-scanning. > Modifiable to various types of abutments.
> Connected with the Guide Pin (2SSFT01SL). Crown Bridge > CCM alloy core for precise connection.
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench. > Cast with non-precious metal or gold alloy.
> Tightening torque force: 12~15 N.cm. > Connected with the SFIT S or A Ti-Base Screw and SFIT Absolute S or A Ti-Base Screw.
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
REGENERATIVE SOLUTION
COWELL®
170 SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base 171
COWELLMEDI HISTORY
Component selection guide for Intra-oral scanning Component selection guide for Model-scanning
procedure procedure
the Sub. Multi SFIT Ti-Base System the Sub. Multi SFIT Ti-Base System
SUB. SUB.
HEXAGON HEXAGON
SYSTEM SYSTEM
REID
Crown
Crown
Multi Polishing Protector
(Hex) (N-Hex)
Multi Scanbody
(Hex) (N-Hex)
Multi Scanbody
(Hex) (N-Hex)
(Hex) (N-Hex)
REGENERATIVE SOLUTION
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short
COWELL®
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short
172 SFIT Ti-Base System : Sub. Multi SFIT Ti-Base SFIT Ti-Base System : Sub. Multi SFIT Ti-Base 173
COWELLMEDI HISTORY
Multi S Abutment Diameter Ø4.5 Ø5.5 Abutment Screw Length
Length 2 2 Diameter
7.5 6.5
D Cuff 1.2 Hex.
2SMS451 2SMS551 2.15 2SSHR300 2SSHR400
L 1
D
C 2 2SMS452 2SMS552 > Packing unit: 1 Abutment Screw.
1 Piece 3 2SMS453 2SMS553 > To connect the Multi A Abutment.
L
> Tightened with the 1.2 Hex Driver and Torque Wrench.
4 2SMS454 2SMS554
5 2SMS455 2SMS555
REID
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Integrated with the screw and abutment (solid screw).
> Use the S Holder for more stable position.
> Tightened with the S Machine or S Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
> Use the Multi Scanbody for digital flow.
> Abutment level impression.
REGENERATIVE SOLUTION
COWELL®
174 SFIT Ti-Base System : Sub. Multi SFIT Ti-Base SFIT Ti-Base System : Sub. Multi SFIT Ti-Base 175
COWELLMEDI HISTORY
Multi Pick-up Impression Coping Multi SFIT S Ti-Base
D 1.2 Hex Type Hex N-Hex
Type Hex N-Hex 22..3
2.3
.3 Multi S & A
Abutment Diameter Ø4.5 Ø4.5 Ø5.5 Ø4.5 Ø4.5 Ø5.5
Multi S & A 2.3
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5 Length
L 3.5 3.5 3.5 3.5 3.5 3.5
Diameter
L Length Ø4.65 Ø5.65 Ø4.65 Ø5.65 Diameter
C Cuff Ø5 Ø5.3 Ø5.7 Ø5 Ø5.3 Ø5.7
9 2SMIH45 2SMIH55 2SMIN45 2SMIN55 D 0.5 2SMSFT45H 2SMSFT55H 2SMSFT45N 2SMSFT55N
Ø5 Ø5.3 Ø5.7
> Packing unit: 1 Multi Pick-up Impression Coping + 1 Guide Pin (2SMGP012). 1.5 2SMSFT40H 2SMSFT40N
> For open tray impression.
> Connected with the Guide Pin. > Packing unit: 1 Multi SFIT S Ti-Base + 1 Multi SFIT S Ti-Base Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench. Hex > Used over both Multi S or A Abutment.
Hex N-Hex > For Screw Retained prosthesis.
> Tightening torque force: 12~15 N.cm.
REID
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Connected with the Multi SFIT S Ti-Base Screw.
L > Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
C > Tightening torque force: 30 N.cm.
D
> Abutment level impression.
Ø5 Ø5.3 Ø5.7
> Packing unit: 1 Multi Transfer Post + 1 Guide Pin (2SMTHS100). Multi SFIT A Ti-Base
> For closed tray impression. Type Hex N-Hex
> Packing unit: 1 Multi SFIT A Ti-Base + 1 Multi SFIT A Ti-Base Screw.
Hex > Used over both Multi S or A Abutment.
> For Screw Retained prosthesis.
> Gold color for more translucent restoration.
Multi Digital Analog > Library available for EXOCAD®, 3Shape® & others.
REGENERATIVE SOLUTION
COWELL®
176 SFIT Ti-Base System : Sub. Multi SFIT Ti-Base SFIT Ti-Base System : Sub. Multi SFIT Ti-Base 177
COWELLMEDI HISTORY
Multi SFIT S Ti-Base Screw Height
Diameter
Ø2.3 Multi Holder
1.2 Hex 5.5 2SMCS100SF
H
2..3
22.3
.3
2.3
> Packing unit: 1 Multi SFIT S Ti-Base Screw. Type
> To connect the Multi SFIT S Ti-Base. Height Hand
H
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench. 20 KMHS01
S Holder
> Packing unit: 1 Multi S Holder.
> To position the Multi S Abutment more stably.
REID
H
Type
Height Hand
20 KMHA01
Diameter
Multi SFIT A Ti-Base Screw Height Ø2.3
A Holder > Packing unit: 1 Multi A Holder.
1.8 Stargrip 5.5 2SMCS100AF > To position the Multi A Abutment more stably.
1.2 Hex Driver
2.3
> Packing unit: 1 Multi SFIT A Ti-Base Screw.
> To connect the Multi SFIT A Ti-Base.
REGENERATIVE SOLUTION
COWELL®
178 SFIT Ti-Base System : Sub. Multi SFIT Ti-Base SFIT Ti-Base System : Sub. Multi SFIT Ti-Base 179
COWELLMEDI HISTORY
Component selection guide for • Intra-oral scanning
the Int. SFIT Ti-Base System • Model-scanning
SFIT S Ti-Base
1.2 Hex
3.5
Type Octa N-Octa
L
INT. Platform Ø4.8 Ø4.8 Ø5.9 Ø4.8 Ø4.8 Ø5.9
[Fixture Dia.] [Ø3.5 / Ø4.0 / Ø4.5] [Ø3.5 / Ø4.0 / Ø4.5] [Ø5.0 / Ø6.0] [Ø3.5 / Ø4.0 / Ø4.5] [Ø3.5 / Ø4.0 / Ø4.5] [Ø5.0 / Ø6.0]
OCTAGON C
SYSTEM Diameter Ø3.5 Ø5 Ø6.2 Ø3.5 Ø5 Ø6.2
D Length
Cuff 3.6 3.6 3.6 3.6 3.6 3.6
Ø3.5 Ø5 Ø6.2
0 ISFO35035 ISFN35035
1 ISFO50135 ISFO60135 ISFN50135 ISFN60135
REID
Crown Octa 2 ISFO50235 ISFO60235 ISFN50235 ISFN60235
3 ISFO50335 ISFO60335 ISFN50335 ISFN60335
Scanbody
1.8 Stargrip
SFIT A Ti-Base
3.5
REGENERATIVE SOLUTION
the dedicated Stargrip Abutment Screw.
> Tightening torque force : 30 N.cm (50 N.cm Max.).
Healing
Fixture Cover Screw Headless Screw Abutment
COWELL®
180 SFIT Ti-Base System : Int. SFIT Ti-Base SFIT Ti-Base System : Int. SFIT Ti-Base 181
COWELLMEDI HISTORY
SFIT S Ti-Base Screw Transfer Post
SFIT S Ti-Base Cuff 0 1 2 3 D
1.2 Hex Height
Diameter 9 10.6 11.6 12.6
Ø2.3 ISFS00S ISFS10S ISFS20S ISFS30S Type Octa N-Octa
D
Platform
> Packing unit: 1 SFIT S Ti-Base Screw. L [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
2 Pieces 1 Piece Fixture Dia.
H > Used to connect the SFIT S Ti-Base. Length Ø4.8 Ø5.9 Ø4.8 Ø5.9
ISFS00S: SFIT S Ti-Base with Cuff 0, ISFS10S: SFIT S Ti-Base with Cuff 1,
11.5 ITOR400 ITOW500 ITNR400 ITNW500
ISFS20S: SFIT S Ti-Base with Cuff 2, ISFS30S: SFIT S Ti-Base with Cuff 3.
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench. > Packing unit: Octa - 1 Transfer Post + 1 Guide Pin (Regular: ITOR400S / Wide: ITOW500S)
N-Octa - 1 Transfer Post (solid screw).
> For closed tray impression.
Octa N-Octa > Connected with the Guide Pin.
REID
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.
SFIT A Ti-Base Screw
SFIT S Ti-Base Cuff 0 1 2 3
1.8 Stargrip Height
Diameter 9 10.6 11.6 12.6
Ø2.3 ISFS00A ISFS10A ISFS20A ISFS30A
D
Diameter
SFIT Ti-Base Setting Screw Height Ø1.95
1.2 Hex 7.5 ISFSS100
REGENERATIVE SOLUTION
COWELL®
182 SFIT Ti-Base System : Int. SFIT Ti-Base SFIT Ti-Base System : Int. SFIT Ti-Base 183
COWELLMEDI HISTORY
Component selection guide for • Intra-oral scanning
• Model-scanning
the Sub. Hybrid Ti-Base System
Hybrid S Ti-Base
D
SUB. Type Hex N-Hex
HEXAGON L
1.2 Hex.
REID
Crown 3 2SLH434 2SLH534 2SLH634 2SLN434
Hex > Packing unit : 1 Hybrid S Ti-Base + 1 Abutment Screw.
> For Screw-Cement or Cement Retained Abutment.
D
> Titanium base for strength of CAD/CAM customized abutment or crown.
> Gold color for more translucent restoration.
L
> Lingual surface hole for more esthetic restoration (Ø4.0).
> Right angled (Ø4.0) and humped design (Ø5.0, Ø6.0) for anti-rotation of prosthesis.
C > Library available for EXOCAD®, 3Shape® & Others.
(Hex) (N-Hex) (Hex) (N-Hex) (Hex) (Hex) (N-Hex) > Connected with the Abutment Screw (2SSHR200).
Hybrid L Ti-Base
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short
REGENERATIVE SOLUTION
COWELL®
184 InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base 185
COWELLMEDI HISTORY
Hybrid A Ti-Base Bite Impression Coping
Max 25° Type Hex
D Type Hex(Short) Hex(Long) Hex(X-Long)
Ø1.8 Diameter Ø4.0
L Diameter Ø4.5 Ø4.5 Ø4.5
2.15 Length L
Cuff 3.75 Cuff
C Length 2 4 6
0.8 2SLH404A C 4.0 2SBIC45S 2SBIC45L 2SBIC45X
2 2SLH424A
D
3 2SLH434A > Packing unit : 1 Bite Impression Coping (Inbuilt Guide Pin).
> Designed to simultaneously take bite and impression.
> Packing unit : 1 Hybrid A Ti-Base + 1 Abutment Screw. > For Closed Tray Impression (Bite Impression).
Hex > For Screw-Cement or Cement Retained Abutment. (Short) (Long) (X-Long) > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Titanium base for strength of CAD/CAM customized abutment or crown.
> For Fabrication of Angulated Screw Channel up to 25°.
REID
> Library available for EXOCAD®, 3Shape® & Others.
Hex
> Connected with the Stargrip Abutment Screw (2SLAH100, 2SLAH200 & 2SLAH300).
> Tightened with the Angulated Screw Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work.
> Fixture level impression.
Hex N-Hex > Connected with the Abutment Screw (2SSHR100). > Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (2SISR001SS / 2SISR001SL).
> Tightened with the 1.2 Hex Driver and Torque Wrench. > For open tray impression.
(Short) (Short) (Long) (Short) (Short) (Long)
> Tightening torque force : 30 N.cm. > Connected with the Guide Pin.
> Use the Scanbody for 3D Work. > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Fixture level impression.
Hex N-Hex 2 Pieces
REGENERATIVE SOLUTION
> Tightening torque force : 15~20 N.cm.
COWELL®
186 InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base 187
COWELLMEDI HISTORY
Transfer Post Abutment Screw
D
Type Hex N-Hex
Diameter 1.2 Hex. 1.2 Hex. Diameter
Length / Cuff Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5 Height 2.45 2.15
L
9 (Short) / 2 2STH45S 2STH55S 2STH65S 2STN45S 2STN55S 2STN65S D D 8.5 2SSHR100 2SSHR200
11 (Long) / 4 2STH45L 2STH55L 2STH65L 2STN45L 2STN55L 2STN65L > Packing unit : 1 Abutment Screw.
C H > 2SSHR100 : Hybrid Block / Scanbody.
> Packing unit : 1 Transfer Post + 1 Guide Pin (Hex) / 1 Transfer Post (N-Hex, Solid Type). > 2SSHR200 : Hybrid S & L Ti-Base.
> For closed tray impression. > Tightened with the 1.2 Hex Driver and Torque Wrench.
(Short) (Long) (Short) (Long) > Connected with the Guide Pin (2STH001SS / 2STH001SL). 2SSHR100 2SSHR200
> Tightened with the 1.2 Hex Driver and Torque Wrench.
2 Pieces 1 Piece
REID
Hex N-Hex
Cuff
Length
Ø4.5
2
Ø5.5
2
• Model-scanning D
C 2 2SMS452 2SMS552
1 Piece 3 2SMS453 2SMS553
SUB. 4 2SMS454 2SMS554
HEXAGON
SYSTEM 5 2SMS455 2SMS555
Crown > Packing unit: 1 Multi S Abutment.
> For Screw-Retained Prosthesis.
> Titanium base for the Multi Hybrid Ti-Base.
> Gold color for more translucent restoration.
REID
> Library available for EXOCAD®, 3Shape® & others.
Multi Polishing Protector
> Integrated with the screw and abutment (solid screw).
> Use the S Holder for more stable position.
> Tightened with the S Machine or S Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
> Use the Multi Scanbody for digital flow.
> Abutment level impression.
(Hex) (N-Hex)
Abutment Screw
(Hex) (N-Hex)
Height
Multi S Abutment Multi A Abutment Multi Protection Cap 1.2 Hex. Diameter 7.5 6.5
2.15 2SSHR300 2SSHR400
D
> Packing unit: 1 Abutment Screw.
> To connect the Multi A Abutment.
H
> Tightened with the 1.2 Hex Driver and Torque Wrench.
REGENERATIVE SOLUTION
Healing
Fixture Fixture Cover Screw
COWELL®
Abutment
Submerged Short
190 InnoFit® Hybrid Ti-Base System : Sub. Multi Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Multi Hybrid Ti-Base 191
COWELLMEDI HISTORY
Multi Protection Cap Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Multi Transfer Post
Diameter
Type Hex N-Hex
D Height Ø5.2 Ø6.2 D
Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
5 2SMPC45 2SMPC55
Diameter
H L Length Ø4.5 Ø5.5 Ø4.5 Ø5.5
> Packing unit : 1 Multi Protection Cap.
7.5 2SMTH45 2SMTH55 2SMTN45 2SMTN55
> Protection from cheek and tongue for gingival healing period.
> Gingival retraction for prosthodontic margin of abutment.
> Alternative usage for sub-structure of temporary prosthesis. > Packing unit: 1 Multi Transfer Post + 1 Guide Pin (2SMTHS100).
> For closed tray impression.
Hex N-Hex > Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.
REID
Multi Digital Analog
Multi S & A
Abutment Diameter Ø4.5 Ø5.5
REGENERATIVE SOLUTION
D > Packing unit : 1 Multi Cylinder Screw.
> Connected with the Multi Scanbody, Multi Hybrid Ti-Base.
H > Tightened with the 1.2 Hex Driver and Torque Wrench.
COWELL®
> Tightening torque force : 30 N.cm.
192 InnoFit® Hybrid Ti-Base System : Sub. Multi Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Multi Hybrid Ti-Base 193
COWELLMEDI HISTORY
Lock Abutment
Component selection guide for • Intra-oral scanning D
Diameter
Cuff
Length
Ø4.5
2.15
• Model-scanning
the Sub. Lock Hybrid Ti-Base System L
C
0.5 2SLA400
1 2SLA410
2 2SLA420
SUB. 3 2SLA430
HEXAGON
SYSTEM 4 2SLA440
Crown > Packing unit : 1 Lock Abutment.
> For Screw-Retained Prosthesis.
> Titanium base for Lock Hybrid Ti-Base.
> Gold color for more translucent restoration.
REID
> Integrated with screw and abutment.
> Tightened with the Lock Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.
Lock Hybrid Ti-Base
Intra-oral Model
Scanning Scanning
Lock Scanbody
Diameter
Ø4.5
REGENERATIVE SOLUTION
Healing
Fixture Fixture Cover Screw
COWELL®
Abutment
Submerged Short
194 InnoFit® Hybrid Ti-Base System : Sub. Lock Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Lock Hybrid Ti-Base 195
COWELLMEDI HISTORY
Lock Pick-up Impression Coping
Length
Diameter
Ø4.5 Lock Cylinder Screw
Diameter
16 2SLIH45 1.2 Hex. Height Ø2.3
L 4.8 2SLCS200
> Packing unit : 1 Lock Pick-up Impression Coping + 1 Guide Pin (2SLIH45S).
> For open tray impression. 2.3
> Packing unit : 1 Cylinder Screw.
H > Connected with the Lock Scanbody, Lock Hybrid Ti-Base.
D
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
REID
COWELL® IMPLANT SYSTEM
Lock Digital Analog Lock Ratchet Driver
D Diameter
Length Ø3.5 H
L Type
2.2 2SLLA35 Height Ratchet
> Packing unit: 1 Lock Digital Analog. 14.2 KRLRD18
> Used for both 3D printed model (RP) and stone model.
H
28.5 KRLRD28
> Packing unit : 1 Lock Ratchet Driver.
> To install the Lock Abutment by hand.
REGENERATIVE SOLUTION
COWELL®
196 InnoFit® Hybrid Ti-Base System : Sub. Lock Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Lock Hybrid Ti-Base 197
COWELLMEDI HISTORY
Hybrid S Ti-Base
Component selection guide for • Intra-oral scanning D
• Model-scanning
the Sub-N. Hybrid Ti-Base System L
1.2 Hex.
Type Hex
2.25 Diameter Ø4.0
C Length
Cuff 3.75
SUB-N.
HEXAGON 0.8 SLH404N
SYSTEM 2 SLH424N
3 SLH434N
Crown Hex
> Packing unit : 1 Hybrid S Ti-Base + 1 Abutment Screw. > Library available for EXOCAD®, 3Shape® & Others.
> For Screw-Cement or Cement Retained Abutment. > Connected with the Abutment Screw (SSHR100N).
REID
> Titanium base for strength of CAD/CAM customized > Tightened with the 1.2 Hex Driver and Torque Wrench.
abutment or crown. > Tightening torque force : 30 N.cm.
> Gold color for more translucent restoration. > Use the Scanbody for 3D Work.
> Lingual surface hole for more esthetic restoration. > Fixture level impression.
> Right angled for anti-rotation of prosthesis.
(Hex) (Hex) (Hex)
Hybrid S Ti-Base Hybrid L Ti-Base Hybrid A Ti-Base Hybrid L Ti-Base
D
1.2 Hex.
Hybrid A Ti-Base
Max 25°
REGENERATIVE SOLUTION
Fixture Cover Screw Abutment 29(Long) KRBUD20
H
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and
the dedicated Stargrip Abutment Screw.
COWELL®
> Tightening torque force : 30 N.cm (50 N.cm Max.).
198 InnoFit® Hybrid Ti-Base System : Sub-N. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub-N. Hybrid Ti-Base 199
COWELLMEDI HISTORY
Scanbody Digital Analog
D D Diameter
1.2 Hex. Ø3.9
Diameter Ø4.3 Height
Length 12 SDR001N
2.25 Cuff 8
L
2 SSB4329N H
> Packing unit: 1 Digital Analog.
C
L
> Packing unit : 1 Scanbody + 1 Abutment Screw. > Analog of fixture for working cast.
> For both, model scanner and intra oral scanner. > Used for both 3D printed model (RP) and stone model.
> For the Hybrid S and L Ti-Base.
> Made of 100% titanium alloy with a special coating applied.
> No need to spray.
> Connected with the Abutment Screw (SSHR100N).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
REID
> Tightening torque force : 15~20 N.cm.
C
D > Packing unit : 1 Abutment Screw.
> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin. > Tightened with the 1.2 Hex Driver and Torque Wrench.
> For open tray impression. > Tightening torque force : 30 N.cm.
> Connected with the Guide Pin (SIS001SN / SIS001LN).
(Short) (Long) (Short) (Long)
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex N-Hex
REGENERATIVE SOLUTION
COWELL®
200 InnoFit® Hybrid Ti-Base System : Sub-N. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub-N. Hybrid Ti-Base 201
COWELLMEDI HISTORY
Component selection guide for • Intra-oral scanning
Multi S Abutment Diameter
Cuff
Length
Ø4.5
2
• Model-scanning
the Sub-N. Multi Hybrid Ti-Base System D
L
1 SMS451N
SMS452N
2
C
3 SMS453N
1 Piece
SUB-N. 4 SMS454N
HEXAGON
SYSTEM > Packing unit : 1 Multi S Abutment.
> For Screw-Retained Prosthesis.
Crown > Titanium base for the Multi Hybrid Ti-Base.
> Gold color for more translucent restoration.
> Integrated with screw and abutment.
REID
> Library available for EXOCAD®, 3Shape® & Others.
> Use the S Holder for more stable position.
Multi Polishing Protector > Tightened with the S Machine & S Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.
(Hex) (N-Hex)
C 3 SMAH45153BN SMAH45303BN
(Hex) (N-Hex) 4 SMAH45154BN SMAH45304BN
Multi Scanbody
Type N-Hex
Diameter(Angle)
Hex N-Hex 2 Pieces Cuff Ø4.5(15°) Ø4.5(30°)
2 SMAN45152NB
Abutment Screw
1.2 Hex. Height
Multi S Abutment Multi A Abutment Multi Protection Cap Diameter 8.7 9.3
D
1.95 SSHR200N SSHR300N
> Packing unit: 1 Abutment Screw.
H
> To connect the Multi A Abutment.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
REGENERATIVE SOLUTION
Healing
COWELL®
Fixture Cover Screw Abutment
202 InnoFit® Hybrid Ti-Base System : Sub-N. Multi Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub-N. Multi Hybrid Ti-Base 203
COWELLMEDI HISTORY
Multi Scanbody 1.2 Hex.
Multi Digital Analog
Type Hex N-Hex Multi S & A
Ø4.5 Ø5.5
Abutment Diameter
D
Diameter Ø4.5 Ø4.5 Diameter
2.25 L Length Ø4.5 Ø5.5
H 2SMB001H 2SMB001N 2 2SMLA45 2SMLA55
> Packing unit : 1 Multi Scanbody + 1 Cylinder Screw. > Packing unit: 1 Multi Digital Analog.
> For both, model scanner and intra oral scanner. > Replacement of the Multi S or A Abutment shape in working cast.
D
> For the Multi Hybrid Ti-Base. > Used for both 3D printed model (RP) and stone model.
> Made of 100% titanium alloy with a special coating applied. > Select according to dimension of the Multi S or A Abutment.
> No need to spray.
Hex N-Hex > Connected with the Cylinder Screw (2SMCS100).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
REID
> Tightening torque force : 15~20 N.cm.
REGENERATIVE SOLUTION
COWELL®
204 InnoFit® Hybrid Ti-Base System : Sub-N. Multi Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub-N. Multi Hybrid Ti-Base 205
COWELLMEDI HISTORY
Component selection guide for • Intra-oral scanning
• Model-scanning
the Int. Hybrid Ti-Base System
Hybrid S Ti-Base
INT. 1.2 Hex
OCTAGON Type Octa N-Octa
SYSTEM 2.3 Platform
[Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
L
Diameter Ø5.1 Ø6.2 Ø5.1 Ø6.2
C
Length
Cuff 4 4 4 4
REID
D 0.8 ILO4814 ILO5914 ILN4814 ILN5914
Ø5.1 Ø6.2
2 ILO4824 ILO5924 ILN4824 ILN5924
Crown
3 ILO4834 ILO5934 ILN4834 ILN5934
Octa
> Packing unit: 1 Hybrid S Ti-Base + 1 Abutment Screw.
L
> For Screw-Cement or Cement Retained Abutment.
> Gold color for more translucent restoration.
C > Library available for EXOCAD®, 3Shape® & others.
> Connected with the Abutment Screw (ILHS100).
(Octa) (N-Octa) (Octa) (N-Octa) D > Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
Scanbody
Hybrid L Ti-Base
N-Octa
REGENERATIVE SOLUTION
Healing
COWELL®
Fixture Cover Screw Headless Screw Abutment
206 InnoFit® Hybrid Ti-Base System : Int. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Int. Hybrid Ti-Base 207
COWELLMEDI HISTORY
Scanbody 1.2 Hex. Digital Analog
Type Octa Platform
Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
[Fixture Dia.]
D Platform D
[Fixture Dia.] Ø4.8 & Ø5.9 [Ø3.5 / Ø4.0 / Ø4.5, Ø5.0 / Ø6.0] Diameter
Ø4.8 Ø5.9
2.3 Height
Diameter
Length Ø4.5 13.5 IDR001R IDR001W
L
6 ISB406
H
10 ISB410
> Packing unit: 1 Digital Analog.
> Analog of fixture for working cast.
> Packing unit: 1 Scanbody + 1 Abutment Screw (ISHR110). > Used for both 3D printed model (RP) and stone model.
> For both intra-oral scanning and model-scanning. > Select according to fixture platform.
> Made of 100% titanium alloy with a special coating applied.
Octa
> No need to spray.
> Connected with the Abutment Screw (ISHR110).
REID
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.
REGENERATIVE SOLUTION
COWELL®
208 InnoFit® Hybrid Ti-Base System : Int. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Int. Hybrid Ti-Base 209
COWELL® EXPERT INSTRUMENTS COWELL®
EXPERT
An Expert knows what makes the results INSTRUMENTS
REID
3
6
9
12
Aqua Syringe Connector
1mm 2mm 3mm 4mm 5mm 6mm 7mm 8mm 9mm 10mm 11mm 12mm
Ø2.2 X 13
Ø2.8 X 13
Ø3.3 X 13
Ø3.7 X 13
Ø4.2 X 13
Bone Carrier
Aqua Lifter Ø2.8 Ø3.3 Ø3.7 Ø4.2
Aqua Tube
0.5
3
CSE-02
0.5mm 1mm 1.5mm 2mm 2.5mm 3mm
REGENERATIVE SOLUTION
COWELL®
CSE-03
Ø6 Lateral Ø6 Round Ø4
REID
Code KPD01S Drilling Depth 1mm 2mm 3mm 4mm 5mm 6mm
KSDS01 KSDS02 KSDS03 KSDS04 KSDS05 KSDS06
0mm
2. 2.2 Twist Drill 800~1,000 rpm
Code KSTD22 12
9 Code KDG001S
6
3
0
Diameter band 12 11 10 9 8 7 6 5 4 3 2 1
Ø2.8 Aqua Syringe Connector
Ø3.3 It is convenient to measure depth by Flat floor edge minimize damage
REGENERATIVE SOLUTION
Ø3.7
standard as a 3, 6, 9, 12mm. to membrane. Code KSAL01SC
Ø4.2
COWELL®
Aqua Tube
Code KSALT030
Code KTW001
1. Ø3.3 Narrow Fixture
REID
8. Bone Carrier
Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill
> Insert bone graft material using the Bone Carrier.
Soft Bone Normal Bone
Ø3.9
2. Ø3.5 Fixture
Ø3.5
9. Bone Condenser Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill Ø3.3 Crestal Drill
> After connecting the stopper with the Bone Condenser, Soft Bone Normal Bone
elevate bone graft materials to inside of maxillary sinus. or
> Rotate bone graft material using the Bone Condenser to disperse bone
3. Ø4.0 Fixture
Ø1
Code KSBC1022
Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill Ø3.3 Crestal Drill Ø3.7 Crestal Drill
Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill Ø3.3 Crestal Drill Ø3.7 Crestal Drill Ø4.2 Crestal Drill
REGENERATIVE SOLUTION
> If the residual bone is less than 3mm, do not implant the implant, Ø5.0 Fixture Normal Bone : Drilling with the Final Drill before placing implants are required.
but bone graft only. Use a Drill that is one step shorter than the implant (E.g. 10mm implant, 8~9mm Drill).
COWELL®
214 MFS KIT MFS KIT 215
COWELLMEDI HISTORY
Lateral Approach - Components > CSE-02 : as stepwise, after using CSE-01, used for elevation of sinus membrane.
> Drill after fastening the stopper according to the height of the bone.
> Round shape to prevent membrane perforation.
> CSE-03 : as stepwise, after using CSE-02, used for elevation of sinus membrane.
REID
Code KSLD60
Code KSSE03
Code KSC60
Code KSLRD60
4. Sinus Elevator
> CSE-01 : Initial elevation of sinus membrane.
Code KSSE01
REGENERATIVE SOLUTION
8. Implant Placement
COWELL®
216 MFS KIT MFS KIT 217
COWELLMEDI HISTORY
Sinus Lift KIT [KSA001] Sinus Lift
Tap Drill (Ø3.6 ,Ø4.6)
>G Sinus Lift Kit is the world’s most innovating kit for performing maxillary sinus lift, ridge splits, and bone condensing cases. > The Tap Drill uses low speed and high torque to grind through the maxillary bone, and safely elevates sinus without membrane perforation.
> Must be used at 20 rpm / 40~45 N.cm.
This revolutionary kit uses US Patented modified Tap Drills and Spreaders in order to allow any dentists to easily lift, split, or > No irrigation is required.
condense surrounding bone with simple drilling. Dentists can expect more predictable results, and patients can enjoy less
traumatic surgeries with shorter chair time. Ø3.6S 2.7 2.85 D
Diameter Ø3.6 Ø4.6
KMTD36S KMTD46S
Ø4.6S 3.7 3.85 D
REID
Can be used with COWELLMEDI Torque Wrench using Ratchet Adapter.
10
8
35
30
6 25
10
Press the elastic handle with finger
Tip of the drill has U.S. Patented blade that crush through the
cortical bone, and separate sinus membrane without perforations.
Ø4.6S
Adapter need to
connect Machine Driver KMTD32S KMTD38S KMTD42S KMTD48S KMTD51S
with Torque Wrench Ø3.8S 2.5 D
Ø4.6S
Ø3.6S
Ø3.8S
Ø4.8S
Ø5.1S 3.8 D
cortical bone, and separate sinus membrane without perforations.
REGENERATIVE SOLUTION
4
COWELL®
Ø2.9 Drill Torque Wrench
KTWD29SL KTW001
REID
placing Ø4.2~Ø4.5 fixture
(Drilling under 30 rpm)
Drill Speed : 20~30 rpm
Ø3.6GDrill Torque : 45 N.cm
Recommend to lift under 3mm
Drill Speed : 800~2,000 rpm Drill Speed : 800~2,000 rpm Drill Speed : 20~30 rpm
Torque : 45 N.cm If excessive torque occurs
Bone Graft using
Osteotome etc. when using Ø3.8 Spreader,
ⲼOptional
replace to Ø3.6 Tap Drill then
1. Sinus Lift (Ø4.0 Fixture) bone graft
Drill Speed : 20~30 rpm
Torque : 45 N.cm
Immediate Implantation and Sinus Lift Technique with Tap Drill (Ø4.0 Fixture)
Ø3.6 Tap
Ø4.6 Tap
Bone
Point Drill Ø2.2 Drill Ø2.9 Drill Ø4.6GTap Graft Fixture Placement
Drill Speed : 800~2,000 rpm Drill Speed : 800~2,000 rpm Drill Speed : 800~2,000 rpm Drill Speed : 20~30 rpm
Torque : 45 N.cm Ø3.2 Ø3.8 Ø4.2 Ø4.8 Bone Fixture
Bone Graft using Point Drill Ø2.2 Drill Spreader Spreader Spreader Spreader Graft พ
REGENERATIVE SOLUTION
Osteotome etc.
ⲼOptional Drill Speed : 800~2,000 rpm Drill Speed : 20~30 rpm
Torque : 45 N.cm Bone Graft using
Osteotome etc.
COWELL®
ⲼOptional
>GAvoid to over press surrounding alveolar bone using Final Drill before fixture placement in D2.
REID
Bone
Point Drill Ø2.2 Drill Ø3.6GTap Graft Final drill Insertion of Fixture
Ø4.2S
Ø4.8S
Ø5.1S
ⲼOptional Spreader Spreader Spreader Spreader
S Spreader
S
REID
Abutment Removal Abutment Removal
KART01 / KART02 KART03
Tap Repair ⴛ
ⴘ
ⴜ
Tap Repair Driver ⴚ
KTR16 / KTR20 / KTR25
ⴙ
One-time use of the F/R Screw is recommended (bending or fracture may happen if more than 100 N.cm
and using twice may be possible if less than 100 N.cm).
Sufficient irrigation required for removing the fixture.
Fixture Removal System Screw Removal System When the maximum torque is exceeded, the fixture may be bent or fractured.
M1.6
Fixture Removal Screw
KFRS16
Fixture Removal Screw
KFRS20
Fixture Removal Screw
KFRS25
2. Screw Removal System
M1.6 M2.0 M2.5 Talon Drill
Fixture Remover FRS Driver ྙ Check the broken screw size inside the fixture.
M2.0
ྚ Connect the I Guide corresponding to the fixture
Ø3~Ø4
to the Guide Holder and fasten to the fixture.
Fixture Removal Fixture Removal(Sub. Narrow)
Talon Drill Reverse Guide Screw ྛ Insert the Talon Drill into the I Guide Hole.
KFR3515 / KFR3520 KFRSD13 / KFRSD18
ⴚ
Ø5~Ø6 Fixture Removal I Guide (Sub. 2.5 Hex) I Guide (Int. 3.1 Octa) ⴙ
KFR5015 / KFR5020 KSRIG25H KSRIG31O
Torque Wrench
KTW002 Silicon O-Ring KSRIGO01
REGENERATIVE SOLUTION
ⴘ
COWELL®
Guide Holder KSRGH01
If the I Guide and fixture could not be correctly connected, the path is not correct.
REID
Slot Driver
ྙ Used for the damaged solid abutment (1piece type), healing abutment and cover screw.
ྚ Form a slot on the surface of the damaged abutment using round bur.
ⴘ
ྛ Connect the Slot Driver to the formed slot and remove it (counterclockwise).
If the path of the I Guide and fixture did not match, it is difficult to remove the screw because the drill hole is away from
the center of the screw.
Reverse drilling requires removal of chips by irrigation & suction.
The fractured screw may be removed during reverse drill hole creation.
If necessary, fasten to the Machine Adapter and use the hand or Torque Wrench.
ⴚ
ⴙ
ⴘ
REGENERATIVE SOLUTION
COWELL®
226 MFR KIT MFR KIT 227
COWELLMEDI HISTORY
InnoGenic™ GBR Kit [KIGBR001]
>G An all-in-one solution for various types of GBR procedures.
3mm 7mm
KIGFS03 KIGTS07
KIGFS03 KIGTS07
1513 10 7 5 3 0
The length of the product can KIGFS03 KIGTS07
be measured with the scale
marked on the middle tray of KIGFS03 KIGTS07
the kit.
REID
KIGFS03 10mm
0 3 5 7 10 1315
KIGTS10
5mm
Fixing Screw Drill
KIGFS05 KIGTS10
KFSD10
Bone
Bone
KIGFS05 KIGTS10
Drill
Tenting Screw Drill
Tenting Screw
Fixing Screw
KIGFS05 KIGTS10
KTSD14
KIGFS05 13mm
KIGFS07 KIGTS13
5mm
KIGDS05
KIGFS07 KIGTS13
7mm Screw Kit
KIGICS001 KIGFS07 15mm
KIGDS07
KIGTS15
KIGFS07
KIGTS15
Machine KIGFS07
KFSMD24 KIGTS15
0.3mm
Machine KIGTC32
KTSMD24
Tenting Cap
T/Cap
0.3mm
Tenting KIGTC32
Handle
0.3mm
KTSHD70 KIGTC32
Driver Handle Round Bur Bone Trimmer Ø3.5 Drill Ø5.0 Drill 0.9 Hex 0.5mm 0.5mm 1.0mm 1.0mm 1.5mm 1.5mm 2.0mm 2.0mm Ø4.5 Ø4.5(3mm) Ø4.5(3mm) Ø4.5(4mm) Ø4.5(4mm)
KIGH KIGRB10 KIGBT50 KBH35 KBH50 KHD0921 KIGFC4505 KIGFC4505 KIGFC4510 KIGFC4510 KIGFC4515 KIGFC4515 KIGFC4520 KIGFC4520 KIGCC45 KIGHC453 KIGHC453 KIGHC454 KIGHC454
REGENERATIVE SOLUTION
Silicon Shield
COWELL®
KBHDSS01
1EA assembled with Drill.
5EA packed in the lower tray.
• Used without removing the Screw Kit from the • Used to fix the membrane to the bone.
inside of the kit tray (Remove to use if necessary • Place slowly using the Fixing Driver (Machine/Handle). L H
only). Double
• 3, 5 and 7mm length can be selected according to the bone quality. Thread
• Made of special material for autoclaving. In hard bone, use after forming a basic drill hole using the Fixing Screw Drill.
REID
Wedge-shaped
• The wedge-shaped design is advantageous for self-tapping, allowing it to be
* Rotate the upper lid to take out the selected product. design
Ø1.4
fixed without drilling in normal bone.
* • The double thread shortens the placement time.
Membrane
D(Ø,mm) C(mm) L(mm) H(mm) Code
Fixing Screw
Composition 3.0 3.6 KIGFS03 (5mm)
KIGTS07 4
Bone
KIGTS10 4
Bone
Tenting Screw
(Tenting)
KIGTS13 4 Tenting Screw (Tenting)
REGENERATIVE SOLUTION
15.0 17.5 KIGTS15
COWELL®
230 InnoGenic™ GBR Kit InnoGenic™ GBR Kit 231
COWELLMEDI HISTORY
D D
C C
Bone Fixture
L H L H
Tenting Cap (T/Cap) Cover Cap (C/Cap)
• Used to fix membrane on the Tenting Screw.
• Used to fix membrane over the Fix Connector.
• Tightened with the 0.9 Hex Driver.
REID
• For submerged surgery in case of sufficient soft tissue.
• Recommended tightening torque force : 5~8 N.cm. Tenting Cap (T/Cap) Cover Cap (C/Cap)
• Recommended tightened with the 0.9 Hex Driver.
• Recommended tightening torque force: 5~8 N.cm. Membrane
Membrane
Fix Connector (F/Connector)
D(Ø,mm) C(mm) L(mm) H(mm) Code Tenting Screw
3.2 0.3 2.8 3.1 KIGTC32 D(Ø,mm) C(mm) L(mm) H(mm) Code
• Used to fix the membrane along with the Cover Cap or Healing • Used to fix membrane over the Fix Connector. H
L H
Cap after connecting to the fixture. • For non-submerged surgery in case of insufficient soft tissue. L
• Tightened with the 0.9 Hex Driver. • Connect by using the 0.9 Hex Driver.
• Recommended tightening torque force: 12~15 N.cm. • Recommended tightening torque force: 5~8 N.cm.
• Available for the INNO Submerged, Submerged Short Fixtures
and other fixtures compatible with them only.
Healing Cap (H/Cap)
REGENERATIVE SOLUTION
COWELL®
232 InnoGenic™ GBR Kit InnoGenic™ GBR Kit 233
COWELLMEDI HISTORY
Fixing Screw Drill & Tenting Screw Drill Fixing Screw Driver & Tenting Screw Driver (Machine)
H
• Used to place the Fixing Screw / Tenting Screw mainly in hard bone. • Used to place the Fixing Screw / Tenting Screw using Contra-angle.
• Also used to perforate cortical bone when blood supply is required. • Color-banded for distinction (Red : Fixing Screw Driver, Blue : Tenting Screw Driver).
• For normal bone, drill only 3mm deep if necessary.
REID
• Drill before placing the Fixing Screw / Tenting Screw.
• Laser-marked at 3, 5 and 7mm long from the tip of the drill and the length can be Classification D(Ø,mm) L(mm) H(mm) Code Color band
D D
Fixing Driver (Handle)
H
H H
Classification D(Ø,mm) L(mm) H(mm) Code
Fixing Screw 1.6 KFSHD70
Driver
6.0 70.0
Tenting Screw 2.2 KTSHD70
Driver
Classification D(Ø,mm) H(mm) Code
• Used to install the Tenting Cap, Fix Connector, Cover Cap and Healing Cap.
D
H
D(Ø,mm) L(mm) H(mm) Code
L
8 15 *KHD0915
D
D(Ø,mm) L(mm) H(mm) Code Fixing Tenting
1.2 14 21 KHD0921
REGENERATIVE SOLUTION
Screw Driver Screw Driver
COWELL®
* Optional
REID
L • 6 Silicon Shields are included in the Kit (1 is assembled with the Ø3.5 Harvesting Drill and 5 are
packed in the lower tray).
D
• The maximum drilling depth of the Ø3.5 Harvesting Drill is 12mm, so it needs to be drilled slowly.
• Remove while rotating the drill.
• Recommended drilling speed : 300~500 rpm. H L H L
D(Ø,mm) L(mm) H(mm) Code
D
1.0 9.5 34.0 KIGRB10 D(Ø,mm) L(mm) H(mm) Code D
6 14.3 KBHD4550
• Used to perform osteoplasty on the outer wall of remaining bone all during * Refer to the Innogenic™ Autobone Harverst Kit Catalog for details.
GBR and to flat the bone surface for improving the fit of membrane.
• Used to remove remaining granulation tissue of bone defect part (use instead
of surgical curette).
114mm
0.4 cc
REGENERATIVE SOLUTION
COWELL®
236 InnoGenic™ GBR Kit InnoGenic™ GBR Kit 237
COWELLMEDI HISTORY
InnoGenic™ Autobone Harvester [KIAH001]
Key Concepts
>G Maximize Your Return On Minimal Investment, Guaranteed!
Maximize your return on minimal investment
The key concept of the Autobone Harvester Plus to harvest a large amount of the autogenous
bone chips from the implant site that can be wasted into the suction during implant drilling procedure.
REID
Features: Drill
Longer
Manufactured after numerous times and various types of test;
Use longer and more times, compared to other products in the market.
Easy to identify
The Color Painting helps choose the right Drill easy.
Ø3.5 Yellow Ø4.0 Orange Ø4.5 Green
Drilling
Depth :
5~7 mm
Simple
The Stopper Holder is fastened with the Stopper and moves
forward and backward when drilling, and it is simple to
control drilling depth up to 5 to 7mm.
Ø3.5 Dril Ø4.0 Dril Ø4.5 Dril Ø5.0 Dril Ø6.0 Dril
KBH35 KBH40 KBH45 KBH50 KBH60
REGENERATIVE SOLUTION
KBHD3540 KBHD4550 KBHD60 KBHDSS01
COWELL®
238 InnoGenic™ Autobone Harvester InnoGenic™ Autobone Harvester 239
COWELLMEDI HISTORY
Features: Stopper & Silicon Shield Harvesting sequence :
Implant Site using Ø3.5/4.0
For Ø3.5 & 4.0 Drill
Harvesting Drill with the Silicon Shield
Stopper
Used by fastening to the
REID
Stopper Holder of Ø3.5 & 4.0 Drill.
Drilling Depth
: 7mm
Drilling Depth
For 6.0 Drill : 5mm
Stopper
Used by fastening to the
Stopper Holder of Ø6.0 Drill.
REGENERATIVE SOLUTION
COWELL®
240 InnoGenic™ Autobone Harvester InnoGenic™ Autobone Harvester 241
COWELLMEDI HISTORY
Harvesting sequence :
COWELL® BMP TREPHINE KIT [KBT001]
Buccal Bone Harvesting
>G An easy-to-use kit with drills and instruments for block-type bone collection, failed fixture removal,
using Ø3.5/4.0/4.5/5.0/6.0 crestal & window approach sinus lift and bone chip extraction.
Harvesting Drill
REID
Select the drill according to its * For Ø3.5&4.0 Harvesting Drill,
using with the Silicon Shield is
diameter and clinical indications. highly recommended.
A Clinical Case using Ø3.5/4.0 Harvesting Drill Guide & Block Bone Trephine Drill
Trephine Drill II Trephine Drill III
Ø6 Ø7 Ø8
Drilling at 300 rpm with irrigation was carried out The Silicone Shield was brought into close contact The amount of bone taken was easily ascertained,
after marking implant and harvesting position. with various types of bone level and prevented through the transparent Silicone Shield.
bone chip loss. Ø4 Ø4.5 Ø5 Ø7
* 2 Step Harvesting : Drilling to 7mm is recommended after transferring bone chips to bowl since the Stopper & Silicon Shield are fully filled Ø 5.2 (Inner) KFRT50
with bone chips while 4mm drilling. Window Trephine Drill Ø 7.0 (Outer) KWTT60
REGENERATIVE SOLUTION
Ø 3.5 (Fixture) KTIS35
COWELL®
Implant Site Drill
Ø3.5 Ø4 Ø4.5 Ø5 Ø 4.5 (Fixture) KTIS45
REID
drill is projected 0.5mm
Ø6
Ø7
Ø8
Ø6
Ø7
7.5 Ø 7.0
7
5
3
0
Ø 6.0 Ø 7.0 Ø 8.0 Ø 6.0 Ø 7.0 Ø 8.0
Implant Site Drill Sinus Lift & Bone Chip Extraction Prior to Implant Placement
Diameter Ø 6.0 (Inner) Ø 7.0 (Inner) Ø 8.0 (Inner) Diameter Ø 6.0 (Inner) Ø 7.0 (Inner) Ø 8.0 (Inner)
KBGT60 KBGT70 KBGT80 KBT60 KBT70 KBT80 Diameter Ø 3.5 Ø 4.0 Ø 4.5 Ø 5.0
KTIS35 KTIS40 KTIS45 KTIS50
ⴙ ⴘ
> Used before the final drill is used (simplified drilling sequence).
> Advantageous for securing autogenous bone.
> Less rpm drilling leads to low bone heating.
Ø 3.5
Ø 4.5
Ø4
Ø5
0
Ø 3.5 Ø 4.0 Ø 4.5 Ø 5.0
Ø5
14.5
14 Bone graft and Implant Placement
Implant Site Drill Final Drill
12
Socket Lift elevation
10
8
REGENERATIVE SOLUTION
0
Ø 4.2 Ø 4.7 Ø 5.2
COWELL®
Ø 5.0 Ø 5.5 Ø 6.0
244 COWELL® BMP Trephine Kit COWELL® BMP Trephine Kit 245
COWELLMEDI HISTORY
Atraumatic Extraction Kit [KAE001] 1. Extraction Drill
>G The Extraction Drill is composed of three types of Drills (Ø1.3 / Ø1.7 / Ø2.1) that can be selected according to the case.
>G Used for the immediate and effortless extraction of the root of the tooth with simple procedures.
REID
Code KAAD13 Code KARD17
Ø2.1 Drill 32
12
Ø2.1
Code KAMD21
(3) Convenience
A very simple and convenient root extraction is possible, compared to the existing extraction method. Ø1.8 Screw
The procedure time is reduced due to the simple procedure. M2.5 Ø1.8
M2.5 Ø2.2
Length 10 15
* Extra product
M2.5 Ø2.6
REGENERATIVE SOLUTION
Elevator
Code KAMS25
COWELL®
246 Atraumatic Extraction Kit Atraumatic Extraction Kit 247
COWELLMEDI HISTORY
3. Post Driver 6. Elevator
>G After connecting the Post Driver to the Extraction Screw, turn the Torque Wrench in a clockwise direction in order to fix it to the >G The Elevator is used by connecting it with the Torque Head and extracting the root by applying force toward a distal or mesial
hole that was created by the Extraction Drill (recommended torque : 30 N.cm or more). direction.
20
13 169
Code KAPD13L
REID
* Connect to the Extraction Screw 5.5 Code KAE01
4. Rest Plate
37
Caution A
Rest Plate
5 KARP001B
Rest Plate Silicon Code
2. Extraction Screw
Connect the Extraction Screw to the Post Driver and fix it to the hole created by rotating it clockwise
(recommended torque: Min. 20 N.cm ~Max. 25 N.cm).
REGENERATIVE SOLUTION
Code KATH80
COWELL®
Connect Post Driver to the Extraction Screw.
CW
REID
Canal filling
5. Torque Wrench
Under Under Extract the tooth by rotating the Torque Head clockwise using the Torque Wrench.
20 N.cm 20 N.cm
CW
Caution C
- Fix the screw with a torque of 20~25 N.cm. If it is not applied, use a thicker Screw.
- The low torque force causes the Screw to fall out during the extraction, and the over torque force fractures tooth root.
Caution D
- Extraction using the Torque Wrench is possible in a root with mesiodistal root.
REGENERATIVE SOLUTION
COWELL®
Rest Plate
- If there are adjacent teeth with 2 or higher swaying degrees, upward pulling or downward pressing should be applied using Direct Surgical Guide Kit [KDSG002]
the Elevator so that the teeth will not receive force during extraction.
>G Used for a flapless surgery.
>G Served as a guide for positioning the drill while measuring the thickness of the buccal bone, thereby preventing bone resorption
and reducing the burden on the patient.
>G Stable Drill positions can be guided to various cases by combining different surgical instruments
(E.g., Position Guide, Linker and Width Guide).
REID
COWELL® IMPLANT SYSTEM
Caution F
(1) Safety
- If there is an adjacent tooth projected to the mesiodistal root, it must be extracted using the Elevator. Safe operation is possible by measuring the thickness of the buccal bone in order to prevent buccal bone resorption.
5.1mm
Sleeve
Post O-ring
6
8mm
Buccal Linker 2
REGENERATIVE SOLUTION
Depth Pin 1mm 2mm 3mm
COWELL®
Code KDBG01 Code KDBG02 Code KDBG03
Black O-Ring
REID
Under 7mm bone width,
under Ø4.0mm fixture
Ø 3.0
Ø 4.0
1mm 1.5mm
Red O-Ring
Bone Width 7~9mm,
Ø 4.0
Ø 4.0
5mm Ø4.0mm~Ø4.5mm fixture
2mm 2mm
Caution B In a defective buccal bone or a thin buccal bone due to tooth extraction, fix the depth pin of the
Buccal Position Guide to the surface 5mm below the gingival or the alveolar crest, from the Blue O-Ring
Ø 4.0
Ø 5.0
lingual or palatal side. Over 9mm Bone Width,
Ø5mm fixture
REGENERATIVE SOLUTION
COWELL®
254 Direct Surgical Guide Kit Direct Surgical Guide Kit 255
COWELLMEDI HISTORY
2. Width Guide
> Select the 7, 8, 9, or 10mm-width guide according to the implant crown diameter, mount it on the
How to use according to the mesiodistal dimension-2
Buccal Position Guide, and Drill the center of the implant (the size is distinguished by color). (Use of the combined Width Guides)
7mm
8mm
9mm
10mm
REID
Ø7 Ø8 Ø9 Ø10
PF
/CZKNNC .CV+PEKUQT UV 2TGOQNCT
2TGOQNCT
Mesiodistal 7.3 7.7 7.3
dimension
Width Guide
Sleeve
%GPVTCN .CVGTCN
/CPFKDNG KPEKUQT KPEKUQT
Mesiodistal
dimension 5.4 6.0
%GPVTCN UV PF
/CZKNNC %CPKPG /CPFKDNG UV /QNCT PF /QNCT
+PEKUQT /QNCT /QNCT
Mesiodistal Mesiodistal 11 10
REGENERATIVE SOLUTION
9.2 8.3 10.5 9.5 dimension
dimension
COWELL®
256 Direct Surgical Guide Kit Direct Surgical Guide Kit 257
COWELLMEDI HISTORY
3. Position Guide
> Guide the Drill position according to the distance between implant centerlines (7, 9, 11mm). Application of the 9mm Position Guide Application of the 11mm Position Guide
(when the mesiodistal distance between (when the mesiodistal distance between
The device consists of three gaps : 3mm, 5mm, and 7mm from the Ø4mm fixture interface.
the two missing teeth is at least 16mm) the two missing teeth is at least 18mm)
> In continuous implants, select the 7, 9, or 11mm Position Guide according to the crown size,
and mount it on the Buccal Position Guide to drill.
7
5 6
6
6 6
5
REID
Ø2.15
7
Maxilla Mandible Mandible
Maxilla
12
4. Linker
Ø 4.0
Ø 4.0
Ø 4.0
Ø2.15
guide and the Buccal Position Guide to drill.
9mm 11mm
7mm
Code K3PP07 Code K3PP09 Code K3PP11
Code K3L11
* The Position Guide must be used in combination with the Buccal Position Guide and linker. 11mm
It cannot guide the Drill position accurately when used alone.
11mm
2
3 3
4
5
4
Buccal Position Guide
Maxilla Mandible
ⴘ Position Guide + Linker ⴙ Position Guide + Linker + Buccal Position Guide
ⴘ The Linker is connected to the Position Guide by setting the linker sleeve in a downward position.
REGENERATIVE SOLUTION
ⴙ After connecting the Linker by setting the sleeve of the Buccal Position Guide in a downward position,
COWELL®
it can be used by adjusting it according to the mesiodistal distance.
258 Direct Surgical Guide Kit Direct Surgical Guide Kit 259
COWELLMEDI HISTORY
5. Point / Crestal Cutter Drill Buccal Position Guide Assembly
> A hole is created on the cortical bone in order to facilitate the Initial Drill.
> The gingiva residue is removed while flattening the uneven alveolar bone surface.
Buccal Position Guide
30.1
Ø2.2 Ø3.95
REID
Code K3CPD01 Guide Handle
Drill
* After connecting the guide handle to the
buccal position guide, fix it at the site where
the implant will be placed and insert the
Guide Drill into the hole inside the Sleeve.
Code KSRGH01
Crestal Cutter
1. Mesio-distal angle: parallel with adjacent tooth Guide Drill
2. Bucco-lingual angle
* The angle of the guide can be predicted according to the shape of the tooth. Fixture Installation Final Drill
* Form basic holes with a crystal cutter. Then, select a drilling sequence according to the implant diameter.
REGENERATIVE SOLUTION
COWELL®
260 Direct Surgical Guide Kit Direct Surgical Guide Kit 261
COWELLMEDI HISTORY
AO4 Surgical Stent [KDSS001]
> Guide the position of Implant and Drill.
Eligible for
> A toothless patient.
70mm > Patient who do not want long-period of surgery.
> Patients suffering from adult diseases such as hypertension and diabetes.
REID
> Patients who need precise implant treatment.
10mm
Instruction
T : 0.4mm
Place the
REGENERATIVE SOLUTION
COWELL®
262 AO4 Surgical Stent AO4 Surgical Stent 263
COWELLMEDI HISTORY
2. SPECIFICATION
Volume-up™ Guide System Volume-up™ Gauge
> Devised for preventing food penetration and forming natural cervical area by restoring contracted For the Ø6.5~Ø8.5mm
buccal alveolar bone & gingiva to the original shape and width. Healing Abutment
Ø10.5
REID
1. CONCEPT Ø9.5
For the Ø3.5~Ø5.5mm
Healing Abutment
• Peri-implant inflammations represent serious diseases after dental implant treatment, which affect both the Ø8.5
surr
surrounding
rounding hard and soft
rounding sof
sofft tissue.
t
Ø6.5 Line
Ø5.5 Line
Ø7.5 Line
Ø4.5 Line
Ø8.5 Line
Ø5
* Actual diameter is 2mm larger than the diameter marked on the Volume-Up™ Gauge
Code KHSG01
(E.g. Ø6.5 marked on the Gauge is actually Ø8.5). Ø6
Ø7
To achieve long term success of implant without complications like peri-implantitis, right position of fixture with
min. 2mm of buccal bone width for buccal gingival regeneration and alveolar bone regeneration at min. 3mm lower
> Used to guide the position of implant placement and to guide the election of the Healing Abutment dimensions in order
position to maintain gingival height is extremely essential.
to keep the cervical portion of the implant prosthesis at the natural tooth width.
> Used with the Volume-up™Parallel Pin for multiple units or bridge.
> Used with Point Drill (Ø2.1mm or less).
Breakaway Stopper
Prevents breakaway from intraoral cavity by connection silk.
Diameter Marking
Marked and Colored by diameter.
The Volume-up™ Guide System helps place implant in the right position according to 2 abovementioned clinical
factors and helps select right dimension of the Healing Abutment to be used as a scaffold while gingival forming. Gingival Height Marking
1~4mm of cuff marking.
1mm
1mm
1mm
REGENERATIVE SOLUTION
Ø6.5 Ø7.5 Ø8.5
1mm
Pin KVPP65 KVPP75 KVPP85
Inserted into the hole formed by the Point Drill.
COWELL®
264 Volume-up™ Guide System Volume-up™ Guide System 265
COWELLMEDI HISTORY
3. PROCEDURE 4. CLINICAL CASE
I. Single Implant
REID
Set the Volume-up™ Gauge on the Position the Point Drill in the drill
implant site according to the diameter insertion groove of the Volume-up™
line marked on the Volume Up™ Gauge. Gauge.
Preoperative view of the The Volume-up™ Gauge was The Ø8.5 Volume-up™ Parallel
REGENERATIVE SOLUTION
* For Healing Abutment selection, refer to the page 33.
COWELL®
266 Volume-up™ Guide System Volume-up™ Guide System 267
COWELL® REGENERATIVE SOLUTION COWELL®
REGENERATIVE
Inspire confidence through a comprehensive approach SOLUTION
REID
microtubule
microtubule C. Nuclear effectors
GTP GDP organizing center R-smad MAPK
2. Features of COWELL® BMP Rho-GDP Rho-GTP C nucleus
I-smad p38
LIMK1
•G Primary closure for soft tissue regeneration is not required. Cofilin
D adhesions D. Retraction
Intergrins FAK
• Regenerates adherent gingiva.
G
REGENERATIVE SOLUTION
COWELL®
270 COWELL® BMP COWELL® BMP 271
COWELLMEDI HISTORY
5. Product Type COWELL® BMP Plus (Two vials)
BMP Coated
BCP Particle
BMP + BCP
BMP Powder
REID
BMP BMP Powder
+ BMP Coated BCP Particle
•G Dose and particle size of the COWELL® BMP BMP 0.1mg BMP 0.25mg
Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size
Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size
REGENERATIVE SOLUTION
COWELL®
272 COWELL® BMP COWELL® BMP 273
COWELLMEDI HISTORY
INNO GF Kit (Two vials + Saline Solution + Syringe) 6. User Guide COWELL® BMP
A. Method*
BMP + BCP +
REID
•G Dose and particle size of the INNO
I GF Kit.
a. Transfer BCP graft material (Vial *). b. Inject distilled water into vial ** with lyophilized
BMP 0.1mg BMP 0.25mg rhBMP-2 power in it and mix with the powder.
Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size
BMP 0.5mg BMP 1mg c. Mix BMP solution with BCP or plus autogenic d. Cover the defect area using a barrier membrane or
/ allograft and apply into the recipient site. suture natural soft tissue without membrane.
Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size
BMP 2mg
REGENERATIVE SOLUTION
d. Mix rhBMP-2 with distilled water e. Aspirate the mixture using a syringe. f. Inject BMP solution through
COWELL®
(saline solution) and wait for soft tissue until needle
10 to 15 seconds before using. of syringe reaches bone.
At surgery
4 weeks
REID
after surgery
8 weeks
after surgery
a. Inject distilled water into vial **with lyophilized b. Aspirate the mixture using a syringe.
rhBMP-2 power in it and mix with the powder. Jung-Bo Huh, et al., Alveolar ridge augmentation using anodized implants coated with Escherichia coli-derived recombinant human bone
morphogenetic protein 2 (Beagle dog).
BMP Dose Distilled Water Dose BMP Dose Distilled Water Dose
8. Clinical Data of COWELL® BMP
•G Vertical height of surrounding bone was compared three months after grafting in extraction socket.
0.1mg 0.1ml 2mg 1.6ml •G The study was conducted at Seoul National University Bundang Hospital, Yonsei University Dental Hospital, and Korea University Guro Hospital.
0.25mg 0.2ml 5mg 4ml
Group Average SD 95%CI †P value
0.5mg 0.4ml 10mg 8ml
REGENERATIVE SOLUTION
Jung-Bo Huh, et al., Multicenter, randomized clinical trial on the efficacy and safety of Escherichia-coli-derived rhBMP-2
with β-Tricalcium phosphate and hydroxyapatite in human extraction sockets.
COWELL®
- J Adv Prosthodont 2011;4 -134.
REID
•G The characteristic biocompatibility and conductivity of the INNO-CaP represent the most safety.
IG1025 0.25g
IG1050 0.5g
0.4~1.0mm
IG1001 1g
IG1002 2g
IG1425 0.25g
IG1450 0.5g
1.0~1.4mm
REGENERATIVE SOLUTION
IG1401 1g
IG1402 2g
COWELL®
278 INNO-CaP INNO-CaP 279
COWELLMEDI HISTORY
INNO OSS™ Allo Allograft
FDBA, Cortical 50% Cancellous 50% DiaBONE Bovine Bone Substitute
REID
•G It is an ideal combination of 50% cortical powder and 50% •G Maximizes bone fusion.
cancellous powder for bone induction. •G Mutually connected porous structure.
• The 50% cortical powder maintains the space of the transplanted area during the new bone formation due to the delayed
G
•G Optimal cell attachment and blood absorption.
absorption rate. [OsteoConduction] •G Stimulates activity of osteoclast and osteoblast.
•G 50% cancellous powder is rich in minerals and collagen that promote cell adhesion, bone remodeling, and vascular re-formation.
[OsteoInduction]
Method of Use (New bone formation clearly observed around grafted bone site)
REGENERATIVE SOLUTION
Turn and pull G2100 0.25~1.0mm 1g G5100 1.0~2.0mm 1g
Remove the syringe’s Hydrate it in saline Graft it in the
out the syringe
rubber cap. solution. desired area.
COWELL®
G2200 0.25~1.0mm 2g G5200 1.0~2.0mm 2g
cap to remove it.
Product Features
•G This product can carry out the functional blocks of the membrane
ane
(soft tissue penetration protection) due to its long absorption period,
REID
and has excellent manipulability.
•G Unlike other imported complete products, this product is produced
uced
under the stringent standards of the FDA in Korea. LW
Y
⽅ LW
Y
⽅
•G The world's first E-Beam sterilization can induce safe and prompt
pt
engraftment. Normal skin 0(*$'(503/86 Other product
[Before
Application sterilization]
•G Mucogingival defect.
•G Soft tissue formation around the implant area.
REGENERATIVE SOLUTION
COWELL®
282 MEGA DERM™ PLUS MEGA DERM™ PLUS 283
COWELLMEDI HISTORY
Diaderm® M Biodegradable Atelocollagen Membrane BOSS® BMP bone graft and Open Sheet System
REID
• Easy to customize for the application of various cases.
•G Diaderm® made from high purity atelocollagen has high biocompatibility, mechanical strength, resistance to enzymatic degradation • Primary closure may be not required.
and flexibility. • The result may come out the best using osteoinductive material.
80
• When residual bone is not sufficient for implant placement, the BOSS® can induce both vertical and horizontal
67.9% augmentation upon implant placement.
60
• The BOSS® consists of abutment and guide for maintaining the space of regeneration of osseous and soft tissues.
20
0
G company Z company B company
REGENERATIVE SOLUTION
•G Store at 1-30°C
Product Code Size
•G Shelf Life : 3 years from the date of manufacture
AS-007020 15X30mm
COWELL®
284 DIA-DERM® M BOSS® 285
COWELLMEDI HISTORY
A. Structure of the product Type 2 (BOSS® Screw) : Placement of implant in cases other than the extraction socket
Diameter Ø2.0
Diameter Ø4.0 Diameter Ø4.0
0.8
Cuff 3
7.7
Length
REID
vertical fixation horizontal fixation
The body is connected to the fixture The interface between body and Before covering, the InnoGenic™ Wif i-Mesh /
Diameter Ø2.0
3 Diameter Ø3.2
27
3.2
Connect abutment body to Fix the InnoGenic™ Wif i-Mesh/ Suture the cover without additional incision
the guide and place the PTFE-Mesh / Ti-Mesh using the cover. (if the InnoGenic™ Wif i-Mesh is used, primary closer is
Instrument
REGENERATIVE SOLUTION
Product Code Size
InnoGenic™ Wif i-Mesh / required). The result shall be much more
PTFE-Mesh / Ti-Mesh. predictable and better if rhBMP-2 solution made by 0.9 Hex Driver KHD0915 15
COWELL®
KHD0921 21
the COWELL® BMP is injected via gingiva into osseous • For connecting the BOSS® Abutment and Cover. KHD0927 27
tissue in the bottom.
REID
100% PTFE, the polytetrafluoroethylene (teflon) sheet which is a biologically inactive and tissue compatible material and 3 months later
the InnoGenic™ Wif i-Mesh is reinforced with titanium frames (Titanium Gr II, ASTM F 67) embedded between two layers
of PTFE sheets.
• Removal of Wif i-Mesh • Dense periosteum layer has been
formed
InnoGenic™ Wifi-Mesh
> Packing unit : 1ea InnoGenic™ PTFE-Mesh
Features
BTP1424AA BTP1424AB BTP1525BB BTP1725CA
REGENERATIVE SOLUTION
BTP2030AB BTP2530AB BTP3040AB the InnoGenic™ PTFE-Mesh and remove.
COWELL®
288 InnoGenic™ Non-resorbable Membrane InnoGenic™ Non-resorbable Membrane 289
COWELLMEDI HISTORY
Comparison to other similar products sold in market
MEMO
Classification Product A Product B InnoGenic™ Wifi-Mesh & PTFE-Mesh
SEM Photograph
REID
Ultrastructure Fiber Filter Sheet
Bacterial infection Bacterial toxin penetration Bacterial toxin penetration No Bacterial toxin penetration
at exposure between filters at 50 μm intervals between filters at 2 μm intervals thanks to non porous structure
Action on Exposure Instant Removal Removal on week 3 to 4 Safe for more than 6 weeks
Shielding Function
against Fiber Cell High High Extremely High
Shape-keeping Capability
Large Deformation Shrinkable Deformation No Deformation
against External Force
• The InnoGenic™ Ti-Mesh is made of stamping titanium sheet, also Titanium Gr II, ASTMF 67, which is 100% commercially
pure titanium. The InnoGenic™ Ti-Mesh is non-resorbable surgical mesh to be applied over intraoral defects, especially, tooth
extraction and bone augmented sites.
TMP210 25 x 34 0.07
Features
• Easy to be Customized : Easy to modify the shape according to shape and dimension of the defect.
• Prevention of Displacement : Prevents displacement of the InnoGenic™ Ti-Mesh using the BOSS® Abutment and Screw
inserted and fixed into the 1mm hole of the Ti-Mesh Frame.
• No Memory : The problem of Majority of Titanium Meshes in the market is resilience of the products after certain time.
REGENERATIVE SOLUTION
Due to this problem, patients go through serious pain. The InnoGenic™ Ti-Mesh is, however, made after many times of stamping
process, the InnoGenic™ Ti-Mesh does not come back to the original shape after shape is formed.
COWELL®
290 InnoGenic™ Non-resorbable Membrane
Ver.28
Help your daily practice superior
CWM-Ver.28