You are on page 1of 149

COWELL®

Implant Solution
Help your daily practice superior
Ver.28
SINCE
1994

THE OLDEST
IMPLANT CASE IN KOREA

Help your daily practice superior

BioPlant™ Atlas™ IINNO Implant™

#35: BIOPLANT™, 1st generation of the COWELL® Implant, Korea’s first dental implant developed in 1994.
#25, 36 & 37: ATLAS Implant System™, 2nd generation of the COWELL® Implant, Korea’s first ASD treated Implant.
#32, 33 & 47: INNO Implant System™, 3rd generation of the COWELL® Implant, Nano/CaP soaking technology applied.

 
  




  004

    


  006

®

• Introduction
Process Flow Chart 008
COWELL® Warranty 010
Package System 011
SLA-SH® Surface Treatment 016
COWELL® CLASS 1000 021

• INNO SLA-SH® Implant System


INNO-Fixture Design 024
®#
    • MFS Kit 210

Abutment Prosthetic Protocol 026 • Sinus Lift Kit 218


INNO Submerged Implant 028 • MFR Kit 224
INNO Submerged Short Implant 033 • InnoGenic™ GBR Kit 228
INNO Submerged Narrow Implant 060 • InnoGenic™ Autobone Harvester 238
INNO Internal Implant 076 • COWELL® BMP Trephine Kit 243
INNO External Implant 096
• Atraumatic Extraction Kit 246
Surgical Kit 110
• Direct Surgical Guide Kit 253
• Mini Plus® Implant System • AO4 Surgical Stent 262
Mini Plus® Implant 127 • Volume-up™ Guide System 264
Surgical Kit 132

®! " • Digital Guided Surgery Kit ®!  $  • COWELL® BMP Series 270
InnoFit® Lodestar Plus Kit 136 • INNO-CaP 278
InnoFit® Lodestar Kit 150 • INNO OSS™ Allo 280
• Digital Prosthesis • DiaBone 281
SFIT Ti-Base System • MEGA DERM™ Plus 282
· Sub. SFIT Ti-Base System 160 • Diaderm® M 284
· Sub. SFIT Absolute Ti-Base System 166 • BOSS® System 285
· Sub. Multi SFIT Ti-Base System 172 • InnoGenic™ Non-resorbable Membranes 288
· Int. SFIT Ti-Base System 180

InnoFit® Hybrid Ti-Base System


· Sub. Hybrid Ti-Base System 184
· Sub. Multi Hybrid Ti-Base System 190
· Sub. Lock Hybrid Ti-Base System 194
· Sub-N. Hybrid Ti-Base System 198
· Sub-N. Multi Hybrid Ti-Base System 202
· Int. Hybrid Ti-Base System 206
COWELLMEDI HISTORY
REID
COWELLMEDI

COWELL® IMPLANT SYSTEM


HISTORY
For the first time in Korea,
Beginning with Korea’s First Dental Implant, the COWELLMEDI has been leading the way to the future biomedical
industry with the fusion technology to its E.rhBMP-2 developed for the first time in the world.

COWELL® DIGITAL PRODUCTS


1994 • Developed Korea’s First Dental Implant, the BIOPLANT™ and localized it for the first time in Korea. 2010 • Obtained MFDS manufacturing & sales approval for the COWELL® BMP and held Korea’s First BMP Symposium in Seoul, Korea.

1998 • Founded Asrahi Medical. 2011 • Obtained US patent for E.rhBMP-2 Coated Implant.

1999 • Established R&D corporation with PNU’s Oral and Biotechnology Research Center. 2012 • Obtained MFDS Approval for E.rhBMP-2 Spinal Fusion Clinical Test Plan and launched the INNO SLA Implant System™.

2000 • Converted to COWELLMEDI corporation (Cowellmedi Co., Ltd.) and obtained ISO9001 certificate. 2013 • Obtained US FDA approval for the INNO SLA Implant System™.

COWELL® EXPERT INSTRUMENTS


2002 • Developed ASD surface treatment technology for dental implant and applied for the first time in Korea. 2014 • Established a R&D and Education Organization, REID (Research & Education in Implant Dentistry).

2003 • Obtained US-FDA approval for the BIOPLANT™ Implant System. 2015 • Applied SLA-SH® surface treatment on the INNO SLA Implant System™ ˧ INNO SLA-SH® Implant System.

(*SLA-SH® Surface Treatment : the world's first superhydrophilic surface made by dry process
2004 • Medaled for contribution of developing Korea's first dental implant, the BIOPLANT™, from Korea Government. using Nano/CaP soaking technology. For the details, refer to the pages 16 to 21).

2005 • Obtained GMP, ISO13485 certificate, US FDA approval for the ATLAS Implant System™ and CE (EC) certificate. 2016 • Established a subsidiary in China (COWELLMEDI China) and a training course, ACID(Advance Course in Implant Dentistry)
with MMS (Miami Medical Seminars).

2006 • Established subsidiaries in USA (COWELLMEDI USA) & Taiwan (COWELL Biotech) and 2017 • Developed Collagen based bone graft materials and launched Sonator™ 80’s System.
COWELLMEDI Tissue Engineering Institute for Growth Factors.
2007 • Obtained a patent for E.rhBMP-2 coated dental implant in Korea. 2018 • Launched the InnoGenic™ Wifi-Mesh and InnoGenic™ PTFE-Mesh.

REGENERATIVE SOLUTION
2008 • Established COWELL Training Center in L.A, USA. 2019 • Launched the InnoFit Lodestar Plus Kit, InnoGenic Autobone Harvester Kit, InnoGenic Bone Carrier.

COWELL®
2009 • Obtained MFDS approval for clinical test of E.rhBMP-2, the COWELL® BMP. 2020 • Launched the InnoGenic™ GBR Kit and Spread Fit™ SFIT Ti-Base System.




 



COWELLMEDI HISTORY
REID
Research and

COWELL® IMPLANT SYSTEM


Education in
Implant Dentistry.

COWELL® DIGITAL PRODUCTS


The REID is a global institute, standing for Research and Education in Implant Dentistry. MISSION VISION

COWELL® EXPERT INSTRUMENTS


The REID has been dedicated to researching technology and knowledge from the past to the
future, to creating more predictable concepts of treatment, and to developing cutting edge
products in implant dentistry and related fields as its first objective of the establishment.
To improve how the world dental community ̰
Constructing the future of implant dentistry
and related fields.
As its second objective of the establishment, the REID also has been committed to training dental treats implant dentistry by providing dental
̰
The world-class education provider and research
professionals with world-class clinicians, lecturers and education curricula. professionals with internationally multidisciplinary institute.
education service and state of the art treatment ̰
Sharing more know-hows to have better ideas
concepts as well as comprehensive quality by expending worldwide network of members.
̰
Providing training system accessible to any

REGENERATIVE SOLUTION
research for the benefits of patients.
dental professional across the globe.

COWELL®
006 REID REID 007
COWELLMEDI HISTORY
Process Flow Chart
CNC Machining Cleansing

REID
Precise machining process using state of the art computer numerical control system Cleansing process by ultrasonic wave using the 3rd stilled distilled, vacuum dry and heating dry sterilization enable
fused to the COWELL® Class 1000, operated by world-class technical unit. ultimately sterilized products and no residues are left on products.

COWELL® IMPLANT SYSTEM


Surface Treatment Packing / Sterilization

COWELL® DIGITAL PRODUCTS


The SLA-SH® Surface treatment with biologically active materials to achieve the ideal Osseointegration. Sanitarily packed products at Class 10,000 clean room are sterilized by gamma-ray using radiation isotope.

Inspection Shipping Warehouse

COWELL® EXPERT INSTRUMENTS


REGENERATIVE SOLUTION
Absolutely accurate test and quality control system with cutting edge equipment such as optical profiling measurer, Finished products are sorted and stored in warehouse for immediate delivery.
stereoscopic microscope, micrometer scope and other specialized devices for dental implant manufacturing.

COWELL®
008 Process Flow Chart Process Flow Chart 009
COWELLMEDI HISTORY
COWELL® Warranty Package System
* For more details, visit our website at www.cowellmedi.com
1. Color classification (Coding) by fixture type and external label marking
A. Color classification by fixture type
Submerged Submerged Internal External Submerged Mini Cement Mini Ball
Fixture type (Sub.) Short (Sub.) (Int.) (Ext.) Narrow (Sub-N.) (1P-C.) (1P-B.)

1. Guarantee beneficiary and scope

Products Period Conditions Remarks

REID
The period Package
Implant Lifetime Replacement with equivalent Implant shall begin
from the sale date

2. Scope of Warranty SUB. INT. EXT. SUB-N.


HEXAGON OCTAGON HEXAGON HEXAGON
1) Quality benefits Connection SYSTEM SYSTEM SYSTEM SYSTEM
> In case the product material or the manufacture process is flawed.

COWELL® IMPLANT SYSTEM


Blue Orange Green Emerald Pink
2) Surgical benefits
> In case implants fail to be grafted to the bone.
B. External label marking and color coding by fixture diameter & fixture type
>G Color coding by diameter on the external label.
3. Claim Procedure >G Reuse is prohibited after opening as the product is sterilized.
1) In case certain faults occur after transplanting implants (procedure), the staff in charge shall be contacted
>G After the ampule is opened, care should be taken from dropping which may cause by incomplete fastening.
within 30 days thereafter.
>G Care should be taken from infection after the product is opened and store at room temperature and in a dry place.
2) When such contact is made, the Customer Complaint Report shall be written out, and shall be submitted
together with the concerned product. >G Discard expired products.

COWELL® DIGITAL PRODUCTS


20A060040A0004
4. Exclusions from Warranty Service ST4010SM
1) In case implants are transplanted onto patients with diabetics and alcohol addiction.
Ø4X10mm
Sterilized
INNO Sub. Fixture Caution Using Irradiation
2) In case implants are transplanted onto patients for whom surgical procedures are difficult to perform due to the
history of systematic disease.
Diameter Ø2.5 Ø3.0 Ø3.1 Ø3.3 Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø5.5 Ø6.0
3) In case implants are transplanted onto patients who depend on habitual medications.
INNO Fixture Fixture
4) In case the procedure is not conducted according to the protocol of the COWELLMEDI. (No-Mount) Type(abbr.) Bisque Green Burgundy Orange Yellow Emerald Red Pink Violet Gray

5) In case the procedure is not performed in compliance with biological indication : PRODUCT NAME  COWELL® INNO Implant System
CATALOG No.  ST4010SM Submerged (Sub.) - - - - -
(E.g. distance between buccal wall and implant should be at least 2mm). SIZE  Ø4.0X10mm(Sub.Hex.Taper)
6) In case the procedure is conducted using contaminated surgical devices. LOT NO.  20A060040A Submerged - - - - -
7) In case implants are transplanted onto patients who sustain or are infected with cell issue contamination. DATE OF  2020-01-06 Short (Sub.)

COWELL® EXPERT INSTRUMENTS


MANUFACTURE
USE BY  2025-01-05
8) In case other materials from other companies are mix used with Implants, prosthetic parts and instruments
PACKING UNIT  1EA Internal (Int.) - - - - -
of the COWELLMEDI. STORAGE CONDITION  Store at room temperature and in a dry place.
9) In case the result of investigation by COWELL R&D Institute, Div. of QA and QC shows the issue is not related to the Do Not
Reuse Caution
30˚C
1˚C External (Ext.) - - - - -
products manufactured and provided by the COWELLMEDI. Sterilized
Using
Consult
Instructions
Irradiation for Use
10) In case the information hereby requested, especially, product Lot no., Serial no. or X-ray photos, is missing. Submerged
Manufacturer Cowellmedi Co.,Ltd. - - - - - - - -
11) In case that the concerned products are not returned. Narrow (Sub-N.)
48, Hakgam-daero 221beon-gil, Sasang-gu, Busan,
46986, Republic of Korea TEL.: +82-51-312-2027~8
12) In case the product is damaged due to negligence of handling. Website: http://www.cowellmedi.com
D/T : 218 Trianon LN Villanova PA 19085-1442 USA Mini Cement (1P-C.) - - - - - - - -
13) In case the product is opened and fails to remain sterilized. EC-Representative EC REP : Certification Experts B.V.
Amerlandseweg 7, 3621 ZC Breukelen, The Netherlands
14) In case that the expiry date of the concerned product (not opened products only) is not longer than 1/4.
(01) 08800016106725 Mini Ball (1P-B.) - - - - - - - -
(11) 200106
(10) 20A060040A
(21) 0004

REGENERATIVE SOLUTION
Rx Only
MEDICAL DEVICE CWM-L-004 (Ver.3)

COWELL®
Ex.) INNO SLA-SH® Sub. Fixture (No-Mount)
Dimension : Ø4.0X10mm

010 COWELL® Warranty Package System 011


COWELLMEDI HISTORY
2. Fixture user guide (Embedded in the packaging) 3. Fixture packaging opening and the sequence of the product extraction

COWELL® IMPLANT SYSTEM Instructions for Use Upper Upper

1. Device Description status, and adequacy of bone. Lateral cephalometric radiographs, CT scans and
The COWELLMEDI implant system includes a variety of precision-machined tomograms may also be beneficial. Adequate radiographs, direct palpation and $PWFS4DSFX $PWFS4DSFX
fixtures manufactured from titanium. These implants are surgically inserted into a visual inspection of the fixture site are necessary prior to treatment, planning and
Middle Middle
mandible (the lower jawbone) or a maxillary bone (the upper jawbone) and serve as use of the COWELLMEDI fixtures.
a replacement for patient's tooth root providing a stable foundation for restoration.
7. Adverse Effects
2. Intended for use Some of the complications (loss of fixture anchorage, prosthesis etc.) are possible
To support dental prosthesis as a dental device, which is implanted into alveolar occurrences after surgery. Lack of quantity or poor quality of remaining bone, .PVOU'JYUVSF
bone to recover masticatory function and give better esthetics in patients with infections, poor patient oral hygiene or cooperation, patient discomfort, fixture 'JYUVSF

partially or full edentulous jaws. mobility, local soft tissue degeneration, and unfavorable fixture placement or
alignment are some potential causes for loss of anchorage.
No-Mount Pre-Mount
3. Directions for use

REID
1) Surgery - The first stage 8. Surgical complications
Lower Lower
a. According to the patient's condition, appropriate dental cleaning operations may The implant procedure has risk, including localized swelling, dehiscence,
be performed and preventive antibiotics may be administered prior to implant tenderness of short duration, edema, hematoma or bleeding. Numbness of the
operation. lower lip and chin region following lower jaw surgery, and of the tissue beside the
b. Clean and disinfect the operative site, administer local anesthesia in the area nose following upper jaw surgery, is a possible side-effect of the surgery. Though it
and expose the alveolar bone by making appropriate incisions and reflecting the would most probably be of a temporary nature, in very rare cases, the numbness
gingival tissues along the alveolar crest in the area from where teeth were has been permanent. Gingival-mucosal (gum tissue) ulceration, tissue reaction or
extracted. infection may occur, but generally responds to local care.
c. Drill into the gum in order to implant a fixture into the planned place with
various dental operation tools. The speed of revolution of the drill should be 9. How to manage after implanting the Product
adjusted by the condition of the bone and the kinds of operation tools. Saline a. The upper jaw requires a healing period of 6~8 months depending on the bone
solution should be poured onto the area so that necrosis doesn't occur by heating quality and the lower jaw requires a healing period of 3~5 months depending on Taking out the ampule
of the bone (The speed for all drilling should be less than 1,200 rpm). the bone quality. If pressures such as mastication would be applied to the fixture

COWELL® IMPLANT SYSTEM


d. Remove the external sterile package cover sheet : open the cap of the ampule: during the healing period, early fixation may not be obtained or osseointegration
affix the Fixture Driver (in case of No-mount Fixture) or the Mount Driver (in case may not occur for the fixture within the healing period.
of Pre-mount Fixture) to the Hand-piece and connect it to the fixture : move the b. Once the operator clinically determines that sufficient osseointegration has been
assembled piece to the osteotomy site for the implant using care to prevent the achieved, he/she should begin the stages to produce the dental prosthesis.
assembled piece from being separated or contaminated with foreign materials. c. The Lot number identification tag should be attached to a patient's chart and
e. A fixture is implanted into the bone as planned depth by turning (25~30 rpm) a X-ray film in order to pursue the product when needs be.
hand-piece clockwise with 15~50 N.cm torque. In event that it is hard to insert, d. The operator should determine the osseointegration status of the implant
extend width of bone by Tap Drill or Countersink (less than 1,200 rpm) in order to through X-ray and clinical methods such as percussion and/or reverse torquing.
facilitate better implantation.
f. After finishing implantation, the treated part should be sutured by using a hex 10. Storage / Sterilization and Handling

1 2
driver to connect to the Cover Screw with torque 5 N.cm to prevent the intrusion a. Store at room temperature and in a dry place.
of a foreign substance in the fixture. b. The fixture, fixture mount and cover screw have been cleaned and sterilized
To open, press the upper dotted area Remove the moisture-resistant paper on the
2) Surgery - The second stage by radiation (gamma irradiation) and are ready to use. and take out the sterilized blister. back of the blister, and drop the ampule
a. Incise gingival of upper part of fixture subsequent to bone fusion and remove c. Product packages should be opened just before their use during operation lightly on the palm of a practitioner or
Cover Screw, tighten up Healing Abutment and start gingival curing for prosthesis. and any product beyond the expiration date should not be used.
b. In general, surgery is done by a method that makes prosthesis. d. Only appropriate sterilized surgical tools made specifically for dental implants surgical clothes.
should be used during the operation.

COWELL® DIGITAL PRODUCTS


4. Contraindication
The operation should be reconsidered when the patient has any of the following 11. Expiration date
Fixture separation
conditions. Expiration date of the product is 5 years from manufacturing.
a. Patient with oral infection or inflammation.
b. In the case of low quality bone which will result in an unstable implant. 12. Cleaning & Sterilization
c. Patients who have a drinking problem or mental disease or substance or Cleaning of surgical instruments supplied non-sterile should be performed
medicine abuse. according to current dental standard practices. Select a suitable method of
d. Internal disease such as hematodyscrasia or diabetes and undernourishment. cleaning that removes all visible contamination from the product in sterilized and
e. Any patient who is not suitable for operation. distilled water. After cleaning, package the product appropriately and then
sterilized by autoclave at the minimum condition of 250°F (121°C/15 mins).
5. Warnings
Implant surgery and restoration involves complex dental procedures. For safe and 13. Caution
effective use of the COWELLMEDI fixtures, it is strongly suggested that specialized a. As this product is sterilized by Gamma radiation, should not be used

1 2
training be undertaken since the surgical techniques required to place dental under any circumstances if is open. Hold the ampule with both hands, twist Fasten in two ways.
implants are highly specialized and complex procedures. Improper patient b. Every product is disposable. It should not be reused.
selection and technique can contribute to fixture failure and/or loss of supporting it 45°, and separate the middle part. 1) No Mount -> Fasten the Fixture Driver. Y

COWELL® EXPERT INSTRUMENTS


bone. the COWELLMEDI fixtures are intended for use only in the indicated Care should be taken so that the fixture 2) Pre Mount -> Fasten the Mount Driver.
applications. Dental fixtures must not be altered in any way. The use of electro-sur-
COWELLMEDI Co., Ltd. will not fall.
gical instruments or lasers around metallic fixtures and their abutments is not
recommended due to the risk of electric shock and/or burns. Fixture mobility, bone 48, Hakgam-daero 221beon-gil, Sasang-gu, Busan, 617-801, Republic of Korea
loss, or chronic infection may indicate fixture failure. The treatment should be done Tel. +82-51-312-2027~8 Fax. +82-51-316-2628
in an aseptic condition by an operator who wears an aseptic costume. If the fixture https://www.cowellmedi.com Cover Screw separation
becomes contaminated by the patient's body fluids in any way, the fixture cannot be D/T
used in any other patient.
COWELLMEDI USA INC. 218 Trianon LN Villanova PA 19085-1442 USA
Tel. +1-623-939-1344 Fax. +1-623-939-1472
6. Precautions
The surgical techniques required to place endosseous dental fixtures require EC-REPRESENTATIVE
specialized and complex procedures. Formal training for placement of fixtures is Certification Experts B.V. Amerlandseweg 7, 3621 ZC Breukelen, The Netherlands
recommended.
Important : Determine local anatomy and suitability of the available bone for fixture
placement. Thorough screening of prospective fixture candidates must be
performed. Visual inspection as well as panoramic and periapical radiographs are
essential to determine anatomical landmarks, occlusal conditions, periodontal
2020. 01. 30 / CWM-I-007 (Ver.3)

1 2 Fasten the Hex Driver to the Cover Screw

REGENERATIVE SOLUTION
Separate the upper part of the ampule.
completely. Care must be taken to prevent
patient from swallowing the Cover Screw at

COWELL®
the time of placing.

012 PACKAGE SYSTEM PACKAGE SYSTEM 013


COWELLMEDI HISTORY
4. Abutment packaging and external label marking

Hybrid S Ti-Base
PRODUCT NAME  Dental Implnat
CATALOG No.  2SLH524
SIZE  Ø5X3.75mm C:2(Sub.Hex)
LOT NO.  20A090004A
DATE OF  2020-01-09

REID
MANUFACTURE
USE BY  Not Applicable (N/A)
PACKING UNIT  1SET
STORAGE CONDITION  Store at room temperature and in a dry place.

Consult 30˚C
Do Not Caution Instructions
Reuse for Use 1˚C

Manufacturer Cowellmedi Co.,Ltd.


48, Hakgam-daero 221beon-gil, Sasang-gu, Busan,
46986, Republic of Korea TEL.: +82-51-312-2027~8
Website: http://www.cowellmedi.com
D/T : 218 Trianon LN Villanova PA 19085-1442 USA
EC-Representative EC REP : Certification Experts B.V.

COWELL® IMPLANT SYSTEM


Amerlandseweg 7, 3621 ZC Breukelen, The Netherlands

(01) 08800016104301
(11) 200109
(10) 20A090004A
(21) 0001

The Pioneers in Dental Implant & E.rhBMP-2 Rx Only


MEDICAL DEVICE CWM-L-005(Ver.5)

5. Surgical Kit packaging and external label marking

COWELL® DIGITAL PRODUCTS


INNO Sub. Full Kit
PRODUCT NAME  Reusable Surgical Instrument
CATALOG No.  KCA010F
SIZE  INNO (Full / Sub.)
LOT NO.  20A090004A
DATE OF
MANUFACTURE
 2020-01-09
USE BY  Not Applicable (N/A)
PACKING UNIT  1SET
STORAGE CONDITION  Store at room temperature and in a dry place.

COWELL® EXPERT INSTRUMENTS


Consult 30˚C
Caution Instructions
for Use 1˚C

Manufacturer Cowellmedi Co.,Ltd.


48, Hakgam-daero 221beon-gil, Sasang-gu, Busan,
46986, Republic of Korea TEL.: +82-51-312-2027~8
Website: http://www.cowellmedi.com
D/T : 218 Trianon LN Villanova PA 19085-1442 USA
EC-Representative EC REP : Certification Experts B.V.
Amerlandseweg 7, 3621 ZC Breukelen, The Netherlands
When INNOVATION meets Dental Implant.
(01) 08800016103113
(11) 20109
(10) 20A090004A
(21) 0001

Rx Only
MEDICAL DEVICE CWM-L-006 (Rev.4)

REGENERATIVE SOLUTION
COWELL®
014 PACKAGE SYSTEM
COWELLMEDI HISTORY
SLA-SH® Surface Treatment
by Nano/CaP soaking technology

SLA-SH®:
Sandblasted, Large-grit, Acid-etched and Super-Hydrophilised
> Hydrophilicity by activation with neutralization solution & Nano/CaP soaking technology.

Experience the > Sandblasted with biocompatible grits unlike majority of other implants in market are done with Alumina.
> Macro-pore & micro-pore of Ti-oxide layer mimicking the etched enamel rod of tooth.

REID
superiority of SLA-SH ®
> Even distribution of roughness through the whole portion of implant surface.
> No destruction or alternation of the surface are caused even with torque force of 120 N.cm.
> Acceleration of osseointegration and maximization of BIC.

made by "Nano/CaP soaking technology" > The SLA-SH® is applied for all types of the COWELL® Implant Systems.

1. Evaluation using SEM (Scanning Electron Microscope) Images


A. SLA-SH® Surface magnified X300, 1,000 and 3,000

COWELL® IMPLANT SYSTEM


X300 X1,000 X3,000

COWELL® DIGITAL PRODUCTS


B. Comparison to other SLA treated implants currently sold in the market

" #

COWELL® EXPERT INSTRUMENTS


$ SLA-SH®

Superhydrophilicity, Uniform micro-surface geometry,


> Surface treatment patterns were observed on electron microscope photographs of 5,000 magnifications for top parts of the
Maximized BIC and Acceleration of ossteointegration implants.

REGENERATIVE SOLUTION
Aspiring for 100% perfection with SLA-SH® > Sand-blasted surface conditions were observed in the product A, B and C due to insufficient acid etching patterns in deep parts
as the SLA-SH® is sandblasted with biocompatible grits with even particle size unlike others are done with alumina.

COWELL®
by Nano/CaP soaking technology > The entire surface of the SLA-SH® treated implant showed uniform acid etching patterns. This implies that the
acid etching of the SLA-SH® surface is perfect.

SLA-SH® 017
SLA-SH®

COWELLMEDI HISTORY
2. Evaluation using SSEM (Stereo Scanning Electron Microscope) 3D images 3. The surface activity increased due to the great surface wetness
A. SLA-SH® Surface A. Contact angle measurement evaluation result for the saline solution

Surface Stats 133.06°


Ra : 1.80 ༁ 36.33°
Rq : 2.27 ༁
Rt : 18.49 ༁

Measurement Info

REID
Magnification : 19.93
Measurement Mode : VSI
Sampling : 496.74 nm
After hydrophilicity After superhydrophilicity
Array Size : 640 X 480 After SLA treatment (133.06°)
activation treatment (36.33°) activation treatment (9°)

After neutralization process and Nano/CaP soaking treatment, the sample became extremely hydrophilic
Surface Stats and the surface energy increased, which facilitated expedition of osteoblast activation to be fused to the bone faster.
Ra : 1.95 ༁

COWELL® IMPLANT SYSTEM


Rq : 2.52 ༁
Rt : 19.83 ༁

Measurement Info
Capillarity in the actual clinical setting, which accelerated the penetration of blood.
Magnification : 19.93 ୔ Quoted from the website of Cowellmedi Clinical Research Group (www.e-cowellmedi.com)
Measurement Mode : VSI
Sampling : 496.74 nm
Array Size : 640 X 480 Blood Friendly

B. Relation between surface wetness and roughness

COWELL® DIGITAL PRODUCTS


B. Comparison to other SLA treated implants currently sold in the market

A B C SLA-SH®
After SLA treatment (Ra: 1.78༁) After super-hydrophilicity activation treatment (Ra: 1.90༁)

> There was almost no difference of surface roughness and micro-geometry, and the difference of surface wetness took place
in the same physicochemical properties as surface energy increased by hydrophilicity activation treatment.

COWELL® EXPERT INSTRUMENTS


6QQFSRa : 2.47༁G 6QQFSRa : 1.07༁G 6QQFSRa : 2.65༁G 6QQFSRa : 1.80༁G
-PXFSRa : 3.11༁ -PXFSRa : 1.13༁ -PXFSRa : 2.09༁ -PXFSRa : 1.95༁
%FWJBUJPO༁ %FWJBUJPO༁ %FWJBUJPO༁ %FWJBUJPO༁ C. Physicochemical alternation of surface by hydrophilicity activation treatment

Name Start BE Peak BE End BE Name Start BE Peak BE End BE


> Uniform distribution of Macro-pore and micro-pore.
C1s 290 284.6 280.5 C1s 290.46 284.6 284.6
> Roughness of the SLA-SH® showed 1.90um while the others were 1.08~3.11um. O1s 535.3 530.42 525.6 O1s 538.8 533.73 529.3
Ti2p 468.1 458.78 450.4 Ti2p 468.2 456.76 453.4

After SLA treatment After hydrophilicity activation treatment

> Surface wetness was improved by increased surface energy of C1s, O1s and Ti2p after hydrophilicity activation treatment.

REGENERATIVE SOLUTION
> To maintain and even to enhance surface wetness, superhydrophilicy activation treatment was carried out and contamination
by carbon in the atmosphere is prevented during packing and sterilization.

COWELL®
018 SLA-SH® SLA-SH® 019
COWELLMEDI HISTORY
4. Its safety has been proven through perfect cleaning with an automated system COWELL® CLASS 1000
A. Comparison of surface element tests through X-ray diffraction A SUBTLE DIFFERENCE MAKES THE DENTAL IMPLANT OR NOT
" # $ SLA-SH®
1. Fixture manufacturing tolerance evaluation

Evaluation Item Manufacturing Tolerance

A1
a. The specimen was fixed in Jig.

REID
Method b. Each dimensional difference of 3 inner hexagonal connection sides
> Cutting-edge automated system that produces the 3rd distilled water. (Hex-1, Hex-2, Hex-3) of 5 specimens was measured.
C4
C2
C1 Used Equipment Measuring Microscope and Jig

A2

B3
C3
Each dimensional difference of 3 inner hexagonal sides should be
Criteria
B. Comparison of surface element tests (X-ray Photo-electron Spectroscopy, XPS) no more than ±0.001mm (1.000༁) from 2.500mm.
Unit : % INNO SLA-SH® Submerged Fixture (5 Pieces of ST4510S)
Specimen
Sample C1s O1s Ti2p Si2p N1s #1 #2 #3 #4 #5

B2

B1

COWELL® IMPLANT SYSTEM


" 34.12 45.05 15.11 5.24 0.47 Hex-1 2.499 2.500 2.500 2.500 2.500
# 31.84 46.49 15.22 4.87 1.57 Hex-2 2.499 2.500 2.501 2.500 2.500

A4

A3
$ 32.19 47.58 17.58 2.65 N.D Hex-3 2.500 2.500 2.500 2.501 2.499
SLA-SH® 27.19 50.81 17.61 N.D N.D Average 2.500 2.500 2.500 2.500 2.500
Total Average 2.500
Result (Pass/Fail) Pass
> Quantitative analysis of each surface element found 30% carbon, 47% oxygen, 16% titanium and 4% silicon in all products.
Manufacturing No more than
> For the SLA-SH®, they only consisted of carbons(C1s), oxygen(O1s) and titanium(Ti2p). Tolerance ±0.001mm (1.000༁)

B4
> Sodium hydroxide, the main element of the alkali washing solution, combined with silicon(Si) to form water-soluble
Na2SiO2(OH)2·4H2O(water glass), which removed the other elements.

COWELL® DIGITAL PRODUCTS


2. Prosthetic component manufacturing tolerance evaluation

Evaluation Item Manufacturing Tolerance


C. Comparison of elution tests using combustion ion chromatography
a. The specimen was fixed in Micro-Measuring Instrument.

A1
Unit : ppm Method b. Each dimensional difference of 3 outer hexagonal connection
Sample F- Cl- NO2- SO42- Br- NO3- PO43- sides (Hex-1, Hex-2, Hex-3) of 5 specimens was measured.

" N.D 0.024 0.027 0.002 N.D 0.031 N.D Used Equipment Micro-Measuring Instrument
# N.D 0.027 0.019 0.002 N.D 0.030 N.D C
Each dimensional difference of 3 outer hexagonal connection sides should be
C3
Criteria C2
$ C2
no more than ±0.001mm (1.000༁) from 2.490mm.

A2
N.D 0.071 0.020 N.D N.D 0.023 N.D C1

COWELL® EXPERT INSTRUMENTS


C1

SLA-SH® N.D N.D N.D N.D N.D 0.032 N.D

B3
C3

A2
INNO SLA-SH® Sub. Cemented Abutment (5 Pieces of 2SCH4515)
Specimen

A3
> Similar ions were detected in all the products, but they are not harmful to human because their elements and quantities #1 #2 #3 #4 #5

A4
Hex-1 2.489 2.490 2.490 2.490 2.490

B2
do not affect the human body and those have been proven in many studies.

B1
Hex-2 2.490 2.490 2.490 2.490 2.490
> For the SLA-SH®, no other elements except for NO3- were detected. Alkali washing completely removed the SO42- and

B1
Hex-3 2.490 2.490 2.490 2.490 2.491

B2 B4
Cl- ions of sulfuric acid and hydrochloric acid, which are used for heated acid etching because they form water-soluble salts

A3
Average 2.490 2.490 2.490 2.490 2.490
of Na2SO4 and NaCl.
Total Average 2.490
> No elements that interfere with osteo anagenesis were found from both the surface and elution elements, which showing Pass
Result (Pass/Fail)
that the cleansing process was perfectly carried out.

C1
Manufacturing No more than

REGENERATIVE SOLUTION
C2
Tolerance ±0.001mm (1.000༁)

COWELL®
B4
020 SLA-SH® SLA-SH® 021
COWELL® IMPLANT SYSTEM COWELL®
IMPLANT
Volume-up™ Healing Abutment
Help your daily practice superior Devised for preventing food penetration
SYSTEM
and forming aesthetical cervical area by restoring
contracted buccal alveolar bone & gingiva to the
original shape and width.

Meta G UCLA Abutment


Modification to angulated Easy Temporary Abutment
abutment, customized Temporary restoration for anterior esthetic zone.
abutment and telescopic For simpler and speedier chair-side process.
abutment.

INNO Submerged Narrow Fixture


Designed for anterior esthetic zone with narrow alveolar ridge. Angulated Abutment
Double tapered thread acquires higher primary stability Simple solution for anterior esthetic zone.
through a wedge action.

Milling Abutment
Block abutment to customize contouring.

INNO Submerged Short Fixture


Designed for severe bone resorption. Wide and
deep upper thread prevents the compressive
necrosis of the cortical bone.
Multi S&A and Lock Abutment
Designed for both edentulous and
partially edentulous arches.
A broad range of prosthetic
Miniplus® options allows to meet individual
For mandible anterior spaces requirements of your patients.
and edentulous arch.
Semi-permanent or
temporary solution for
anterior spaces with extremely
narrow ridge.

INNO External Fixture


Stable engraftment of periosteum
in the boundary surface of bone and implant. Ball Abutment
Sonator 80’s S&A Abutment Designed for use with removable
Allows you to treat your patients with overdentures or partial
INNO Submerged Fixture minimum standard of care of an implant supported dentures retained in whole or
INNO Internal Fixture
Designed for all clinical cases including Cemented Abutment overdenture at affordable cost with great satisfaction. in part by endosseous implants
immediate implant placement, immediate loading, One stage restoration with state
Cutting surface is in the maxilla and mandible.
implant depth adjustment, maxillary sinus and etc. of the art design. 4 spiral round cutting
designed for anti-rotation
Simply doing more for your implant treatment. edges maximize the efficiency of Beauty-up™ Abutment
of prosthesis.
self tapping with a sharp edge and
Specially designed to solve esthetical
accommodates bone chips as ideal
and functional challenges
cutting edge pocket space.
when SCRP with angulated screw
channel is required in the anterior portion.
COWELLMEDI HISTORY
INNO-Fixture Design An advantageous design for all clinical cases including immediate
implant placement & immediate loading, implant depth adjustment,
maxillary sinus and etc.

Fixture type Submerged (Sub.) Submerged Short (Sub.) Internal (Int.) External (Ext.) Submerged Narrow (Sub-N.)

11°

REID
Fixture Design

SEM Image, x47

11° Tapered and 2.5 Hex Connection


> Allows the ideal cold welding between the
SUB. INT. EXT. SUB-N.
fixture and the abutment. Connection HEXAGON OCTAGON HEXAGON HEXAGON
SYSTEM SYSTEM SYSTEM SYSTEM
> Prevents micro-sinking of the abutment.

COWELL® IMPLANT SYSTEM


> Excellent compatibility.

Platform Neck Simpler, Speedier and Safer Surgical Kit


> Stable engraftment of periosteum in the boundary
Wide and deep upper thread Sub. / Sub-N. / Int. / Ext. / provide different types of exclusive kits, respectively.
surface of bone and implant.
> Prevents the compressive necrosis of the > Prevents possible infections around the implant.
cortical bone.
> Minimizes the need for Countersink Drills. Sub. KCA010F Int. KCA010FI Ext. KCA010FE
> Reinforces mechanical strength by reinforcing
thickness. Open Thread
> Possible to place deeper even without additional
drilling.

COWELL® DIGITAL PRODUCTS


Double Tapered Thread
> Secures early fixation even for an alveolar socket
or parts with weak bone quality.
> Allows placement to be completed with only
2-4 rotation with half the length of the fixture
inserted in the drill hole. 4 spiral round cutting edges
> Acquires higher primary stability through a wedge > Maximize the efficiency of self tapping with
action even with an additional half turn. a sharp edge.
> Accommodate bone chips as ideal cutting edge Sub.Smart KSA002 Sub. KSI001 Sub-N. KNA001
pocket space.
> Allow soft placement but higher initial stability
(refer to the test table below).

COWELL® EXPERT INSTRUMENTS


Apex Thread with a sharp cutting edge
> Prevents schneiderian membrane from being ripped.
> Allows soft placement but higher initial stability
(refer to the test table below).
All in One Drill : Minimal drilling frequency with Initial and Final Drill
※ Placement torque force (Unit: for 4pcs of Ø4.5X10mm implants Chair time for implantation is shortened because the fixture can be implanted with just three drillings for general bone quality
Shortens the placement time with 5mm from 4 different manufacturers in 5.0 & 5.5mm depth hole of type (when implanting Ø3.5-Ø4.5 fixtures).
2 bone quality test block.
or more of already entered depth as well
as double thread. Classification INNO A B C

REGENERATIVE SOLUTION
Depth 5.0mm 26.2 N.cm 29.2 N.cm 26.8 N.cm 28.4 N.cm
Depth 5.5mm 44.0 N.cm 38.0 N.cm 34.4 N.cm 38.5 N.cm

COWELL®
024 INNO-Fixture Design INNO-Fixture Design 025
COWELLMEDI HISTORY
2. Abutment Level Impression - Prosthesis Fabrication
Abutment Prosthetic Protocol * Two / One Piece Screw Retained Abutment
> For digital procedure, refer to the COWELL® Digital Products.
Submerged & Submerged Short : Multi S | Multi A | Lock | SFIT Absolute
Submerged Narrow : Multi S | Multi A
1. Fixture Level Impression - Prosthesis Fabrication
* Two Piece Screw Retained Abutment * One Piece Cemented Retained Abutment
Submerged & Submerged Short : Absolute | Straight (Direct)
Submerged & Submerged Short : Temporary | Easy Temporary | SFIT S | SFIT A Submerged Narrow : Straight
Internal : SFIT S | SFIT A Internal : Solid | Shoulder
External : Temporary External : Shoulder

* Two Piece Screw-Cement Retained / Cement Retained Abutment

REID
* Two / One Piece Attachment Retained Abutment
Submerged & Submerged Short : Cemented | Angulated | Beauty-up™ | Milling | Meta G UCLA | Plastic UCLA Submerged & Submerged Short : Sonator S | Sonator A | Ball
Hybrid S | Hybrid L | Hybrid A | Ti-Block Internal : Sonator S | Ball
Submerged Narrow : Cemented | Angulated | Temporary | Meta G UCLA | Hybrid S | Hybrid L | Hybrid A External : Ball
Internal : Cemented | Angulated | Meta G UCLA | Hybrid S | Hybrid L
External : Cemented | Angulated | Temporary | Meta G UCLA | Plastic Sleeve Indirect Impression Technique
(No Abutment Modification Applied) Multi Pick-up Sonator Impression
Ø4.5 Abutment Ø5.5 Abutment Ø6.5 Abutment Impression Coping Multi Transfer Post Coping
(with Open Tray)
Pick up (Open Tray)

COWELL® IMPLANT SYSTEM


Remove the Connect the Fasten the Impression Cap Take impression Connect the Lab Analog
Healing Abutment. abutment with on the Abutment. with
t closed
c osed tray.
t ay. with the Impression
p Cap
Connect the Pick-up Impression Coping & Remove the Guide Pin. Connect the Replica with the the fixture. positioned in the imp
impression
ress
Guide Pin and take the impression Impression Coping positioned in tray.
with open tray. the impression tray, form the gum
and pour stone into the tray for
Single Crown : Hex / Octa Type working cast.
Bridge: Non-Hex / Non-Octa Type

COWELL® DIGITAL PRODUCTS


Form the gum and pour The working cast Fasten the Plastic Coping Wax build-up Complete final Try-in final prosthesis
stone into the tray for with the gum. on the Lab Analog on the abutment. prosthesis. with the fixture.
PS working cast. (Absolute).

Remove the Connect the abutment Wax build-up Complete final Try-in final
Healing Abutment. with replica in the cast model. on the abutment. prosthesis. prosthesis
Direct Impression Technique (Abutment Modification Applied)
with the fixture.

COWELL® EXPERT INSTRUMENTS


Transfer (Closed Tray)

Remove the Connect the Modify


M odify the abutment for
fo Take impression Pure stone into the
en
nt.
Healing Abutment. abutment with pathway and aesthetics.
p aestheticss. with closed tray. tray for working cast.
the fixture.

Connect the Transfer Post & Guide Pin and Connect the Replica Interlock the Transfer Post

REGENERATIVE SOLUTION
take the impression with closed tray. with the Transfer Post into the impression tray,
removed from form the gum and pour stone
Single Crown : Hex / Octa Type the impression tray. into the tray for working cast.
Bridge: Non-Hex / Non-Octa Type
Complete final Try-in final prosthesis

COWELL®
The working cast Wax build-up
with the gum. on the abutment. prosthesis. with the fixture.

026 Abutment Prosthetic Protocol Abutment Prosthetic Protocol 027


COWELLMEDI HISTORY
INNO SUBMERGED IMPLANT (Sub.)
System Flow

Fixture Abutment Impression

036p 036p 037p 037p 037p 038p 038p 038p 039p 040p 040p 040p

Fixture Level
Procedure I

Impression
Prosthetic

REID
Cemented Angulated Beauty-up™ Milling Easy Temporary Temporary Meta G UCLA Plastic UCLA Replica Bite Impression Pick-up Impression Transfer Post
Coping Coping

042p 042p 043p 043p 043p 044p 044p 044p 045p 045p
Procedure II
Prosthetic

Multi S Multi A Multi Multi Impression Multi Multi Multi Meta G Multi Plastic Multi Titanium Multi Polishing

COWELL® IMPLANT SYSTEM


Protection Cap Coping Transfer Post Lab Analog ULCA Cylinder UCLA Cylinder Cylinder Protector

Hex 2.5

048p 048p 048p 049p 049p 049p


Procedure III
Prosthetic

Length
7 / 8 / 10 Lock
12 / 14 Lock Lock Pick-up Lock Lock Meta G Lock Titanium
16 / 18mm Protection Cap Impression Coping Lab Analog UCLA Cylinder Cylinder

052p 052p 052p 052p 052p


Diameter
Procedure IV

COWELL® DIGITAL PRODUCTS


Ø3.5 / 4.0 / 4.5 / 5.0 / 6.0
Prosthetic

Absolute Absolute Absolute Absolute Absolute


Protection Cap Impression Cap Lab Analog Plastic Coping
Hex 2.5

Abutment Level
053p
Procedure V

Impression
Prosthetic

Direct
Impression

COWELL® EXPERT INSTRUMENTS


1
2 Straight
Length
4mm

Diameter 055p 055p 056p 057p


Procedure VI

Ø4.0 / 4.5 / 5.0 / 5.5 / 6.0


Prosthetic

Sonator Impression Sonator


Sonator S Sonator A Coping Analog

059p 059p
Procedure VII

REGENERATIVE SOLUTION
Prosthetic

COWELL®
Ball Ball Analog

028 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 029


COWELLMEDI HISTORY
INNO Submerged Implant
No-Mount > Packing unit : 1 Fixture + 1 Cover Screw.

Diameter
Ø3.5
Length

Submerged Fixture 7 -
SUB.
HEXAGON Surface Treatment : SLA-SH® 8 ST3508SM
Hex
8 10 12 14
SYSTEM > Interchangeable with hexagonal morse tapered fixture 10 ST3510SM L
> Internal hex connection (Taper 11°/ Hex 2.5)
12 ST3512SM

REID
14 ST3514SM D

Hex 2.5 Diameter


Ø4.0
Length

7 ST4007SM
8 ST4008SM
7 8 10 12 14 16 18
10 ST4010SM

COWELL® IMPLANT SYSTEM


L
12 ST4012SM
14 ST4014SM
16 ST4016SM D

18 ST4018SM

Diameter
Ø4.5
L Length

7 ST4507SM

COWELL® DIGITAL PRODUCTS


8 ST4508SM
7 8 10 12 14 16 18
10 ST4510SM L
12 ST4512SM
14 ST4514SM
D
16 ST4516SM
D 18 ST4518SM

Diameter
INNO Fixture Code Length
Ø5.0

COWELL® EXPERT INSTRUMENTS


S T 40 10 S M Ex.)
7 ST5007SM
Type body Diameter Length Surface Treatment Mount SLA No-Mount ST4010SM
Submerged Taper Ø4.0 10mm SLA No-Mount 8 ST5008SM 7 8 10 12 14
10 ST5010SM L

12 ST5012SM

S T 40 10 S Ex.) 14 ST5014SM
D
Type body Diameter Length Surface Treatment Mount SLA Pre-Mount ST4010S
Submerged Taper Ø4.0 10mm SLA Pre-Mount
Diameter
Ø6.0
Length

7 ST6007SM
7 8 10 12

REGENERATIVE SOLUTION
8 ST6008SM
L
10 ST6010SM
12 ST6012SM

COWELL®
D
14 -

030 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 031


COWELLMEDI HISTORY
Pre-Mount

Diameter
> Packing unit : 1 Fixture + 1 Cover Screw + 1 Mount.
INNO Submerged Short Implant
Ø3.5
Length
8 10 12 14
7 - Submerged Short Fixture
8 ST3508S Hex SUB.
HEXAGON Surface Treatment : SLA-SH®
10 ST3510S L
SYSTEM > Interchangeable with Hexagonal Morse Tapered Fixture.
12 ST3512S > Internal hex connection (Taper 11°/ Hex 2.5).
14 ST3514S D

REID
Diameter
Ø4.0
Hex 2.5
Length

7 ST4007S 7 8 10 12 14 16 18

8 ST4008S
10 ST4010S
12 ST4012S L

COWELL® IMPLANT SYSTEM


14 ST4014S 1(Machined Surface)
16 ST4016S
18 ST4018S
D
2(Sandblast)

Diameter
Ø4.5
L(SLA)
Length

7 8 10 12 14 16 18
7 ST4507S
8 ST4508S
D
10 ST4510S

COWELL® DIGITAL PRODUCTS


L
12 ST4512S
Pre-Mount > Packing Unit : 1 Fixture + 1 Cover Screw + 1 Mount.
14 ST4514S
16 ST4516S D
Diameter 4 Diameter
18 ST4518S Ø4.0 Ø5.5 4
Length Length
1 1
2 2
Diameter 4 2ST4004S 4 2ST5504S
Ø5.0
Length L L
7 8 10 12 14
D D
7 ST5007S
8 ST5008S

COWELL® EXPERT INSTRUMENTS


Diameter
10 ST5010S L
Ø4.5
Length 4 Diameter 4
12 ST5012S Ø6.0
Length
14 ST5014S 1
1
D 2
4 2ST4504S 2
L
4 2ST6004S
L

D
Diameter D
Ø6.0
Length
7 8 10 12

7 ST6007S Diameter 4
Ø5.0
Length
8 ST6008S
L 1
10 ST6010S 2

REGENERATIVE SOLUTION
4 2ST5004S
12 ST6012S L
14 - D

COWELL®
D

032 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 033


COWELLMEDI HISTORY
Fixture Mount
Prosthetic Procedure I
Length 5.4 Components Selection Guide for Cemented and UCLA Abutment
L
2SMHR001
> Packing unit : 1 Mount + 1 Mount Screw. 2.45 2.15

> Tightened with the 1.2 Hex Driver.


> Tightening torque force : 5~10 N.cm.

Abutment Screw

Cover Screw

REID
D Diameter
Length Ø3.35 Ø3.75 Ø4.15
(15°) (25°) (15° 5mm) (25° 5mm)
L 2SCS000
3
4.2 2SCS001
5.2 2SCS002
> Packing unit : 1 Cover Screw. *Extra Product (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)
> To seal the conical interface of fixture.
Cemented Angulated Beauty-up™ Milling
> The longer Cover Screw for deeply inserted fixture. Abutment Abutment Abutment Abutment
> Tightened with the 1.2 Hex Driver.

COWELL® IMPLANT SYSTEM


>Tightening torque force : 5~10 N.cm.

Healing Abutment
D
Diameter Ø4.5 Ø5.5 Ø6.5 (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)
L
C Length
Cuff 1 2 1 2 1 2 Easy Temporary Temporary Meta G UCLA Plastic UCLA
Abutment Abutment Abutment Abutment
1 2HS4511 2HS5511 2HS6511
2 2HS4522 2HS5522 2HS6522
3 2HS4532 2HS5532 2HS6532
4 2HS4542 2HS5542 2HS6542
5 2HS4552 2HS5552 2HS6552

COWELL® DIGITAL PRODUCTS


7 2HS4572 2HS5572 2HS6572

Diameter Ø7.5 Ø8.5 Ø9.5 Replica


Length
Cuff 2 2 2
3 2HS7532 2HS8532 2HS9532

> Packing unit : 1 Abutment.


> For remodeling gingival contour during soft tissue healing.
> Recommended to use with the Volume-up™ Guide System.
> Select according to gingival height and abutment type.
> Tightened with the 1.2 Hex Driver.
> Tightening torque force : 5~10 N.cm.

COWELL® EXPERT INSTRUMENTS


(Short) (Long) (X-Long) (Hex) (N-Hex) (Hex) (N-Hex)
Bite Impression Coping Pick-up Impression Coping Transfer Post
Volume-up™ Healing Abutment
D

L
Diameter Ø6.5 Ø7.5 Ø8.5
Length
H C Cuff 2 2 2
7.9
3 VUHN6532 VUHN7532 VUHN8532
> Packing unit : 1 Abutment(Inbuilt Abutment Screw).
> Used for an implant procedure to form the gingival tissue and alveolar bone in the form 1mm
of natural teeth and gums by prevention or minimizing the food penetration. off-centered
> Extremely effective when used with the COWELL® BMP.
> Recommended to use with the Volume-up™ Guide System.
> Select according to gingival height and abutment type.

REGENERATIVE SOLUTION
> Tightened with the 1.2 Hex Driver.
> Tightening torque force : 25~35 N.cm.
Healing

COWELL®
Fixture Cover Screw Abutment

034 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 035


COWELLMEDI HISTORY
Cemented Abutment Type Hex
Beauty-up™ Abutment
Angle 15˚ 5mm 25˚ 5mm
1.2 Hex. Diameter Ø4.5 Ø5.5 Ø6.5 15° 5mm
D Type Hex N-Hex Hex N-Hex
Length
Cuff 4 5.5 7 4 5.5 7 4 5.5 7 L
2.15 Diameter Ø3.8 Ø3.8 Ø3.8 Ø3.8
L 1 2SCH4514 2SCH4515 2SCH4517 2SCH5514 2SCH5515 2SCH5517 2SCH6514 2SCH6515 2SCH6517 Length
C
Cuff 5 5 5 5
C 2 2SCH4524 2SCH4525 2SCH4527 2SCH5524 2SCH5525 2SCH5527 2SCH6524 2SCH6525 2SCH6527 Angulated Screw
Ratchet Drive 2 2SBH381525 2SBN381525 2SBH382525 2SBN382525
3 2SCH4534 2SCH4535 2SCH4537 2SCH5534 2SCH5535 2SCH5537 2SCH6534 2SCH6535 2SCH6537
4 2SCH4544 2SCH4545 2SCH4547 2SCH5544 2SCH5545 2SCH5547 2SCH6544 2SCH6545 2SCH6547
D > Packing unit : 1 Abutment (Inbuilt Abutment Screw). > Tightened with the Angulated Screw Ratchet Drive
> For Screw-Cement Retained Prosthesis and Torque Wrench.
Hex N-Hex 5 2SCH4554 2SCH4555 2SCH4557 2SCH5554 2SCH5555 2SCH5557 2SCH6554 2SCH6555 2SCH6557 with angulated screw channel. > Tightening torque force : 30 N.cm.
Hex N-Hex
> Solution for anterior esthetic zone. > Library available for EXOCAD®, 3Shape® & Others.
> The gingival line of the Beauty-up™ Abutment > Use the Scanbody for 3D Work.

REID
Type N-Hex allows more esthetic prosthesis. > Fixture level impression.
Diameter Ø4.5 Ø5.5 Ø6.5 > Oval design allows lower incisal application
(Mesiodistal diameter : 3.8mm).
Length
Cuff 4 5.5 7 4 5.5 7 4 5.5 7
1 2SCN4514 2SCN4515 2SCN4517 2SCN5514 2SCN5515 2SCN5517 2SCN6514 2SCN6515 2SCN6517 * Angulated Screw Ratchet Driver
Type Ratchet
2 2SCN4524 2SCN4525 2SCN4527 2SCN5524 2SCN5525 2SCN5527 2SCN6524 2SCN6525 2SCN6527 Height
24(Short) KRBUD15
3 2SCN4534 2SCN4535 2SCN4537 2SCN5534 2SCN5535 2SCN5537 2SCN6534 2SCN6535 2SCN6537
29(Long) KRBUD20
4 2SCN4544 2SCN4545 2SCN4547 2SCN5544 2SCN5545 2SCN5547 2SCN6544 2SCN6545 2SCN6547 H
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and
5 2SCN4554 2SCN4555 2SCN4557 2SCN5554 2SCN5555 2SCN5557 2SCN6554 2SCN6555 2SCN6557

COWELL® IMPLANT SYSTEM


the dedicated Stargrip Abutment Screw.
> Tightening torque force : 30 N.cm (50 N.cm Max.).
> Packing unit : 1 Abutment + 1 Abutment Screw.
> For Screw-Cement or Cement Retained Prosthesis. Milling Abutment
> Cutting surface for anti-rotation of prosthesis. 1.2 Hex. Type Hex N-Hex
> Gold color for more translucent restoration (Hex) and classification with N-Hex. D
Diameter Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5
> Library available for EXOCAD®, 3Shape® & Others. 2.45 Length
> Connected with the Abutment Screw (2SSHR200). L Cuff 7 7 7 7 7 7
> Tightened with the 1.2 Hex Driver and Torque Wrench. 2 2SMH4527 2SMH5527 2SMH6527 2SMN4527 2SMN5527 2SMN6527
C
> Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work. 4 2SMH4547 2SMH5547 2SMH6547 2SMN4547 2SMN5547 2SMN6547
> Fixture level impression.
> Packing unit : 1 Milling Abutment + 1 Abutment Screw.
> For Screw-Cement or Cement Retained Prosthesis.
Hex N-Hex > Block abutment for customized contouring.

COWELL® DIGITAL PRODUCTS


> Gold color for more translucent restoration (Hex) and classification with N-Hex.
> Connected with the Abutment Screw (2SSHR100).
Angulated Abutment Type Hex-A Hex-B > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
Diameter(Angle) Ø4.5(15°) Ø4.5(25°) Ø5.5(15°) Ø5.5(25°) Ø4.5(15°) Ø4.5(25°) Ø5.5(15°) Ø5.5(25°) > Fixture level impression.
15° / 25° 1.2 Hex.
Length
Cuff 8 8 8 8 8 8 8 8
2.45 1 2SAH45151 2SAH45251 2SAH55151 2SAH55251 2SAH45151B 2SAH45251B 2SAH55151B 2SAH55251B
L
2 2SAH45152 2SAH45252 2SAH55152 2SAH55252 2SAH45152B 2SAH45252B 2SAH55152B 2SAH55252B
C
3 2SAH45153 2SAH45253 2SAH55153 2SAH55253 2SAH45153B 2SAH45253B 2SAH55153B 2SAH55253B
D 4 2SAH45154 2SAH45254 2SAH55154 2SAH55254 2SAH45154B 2SAH45254B 2SAH55154B 2SAH55254B
Hex N-Hex
Easy Temporary Abutment

COWELL® EXPERT INSTRUMENTS


Type N-Hex Type Hex N-Hex
Hex-A D
Diameter(Angle) Ø4.5(15°) Ø4.5(25°) Ø5.5(15°) Ø5.5(25°) 1.2 Hex. Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
Length
Cuff 8 8 8 8 Length
10 10 10 10
L Cuff
Hex-B 2.15
1 2SAN45151 2SAN45251 2SAN55151 2SAN55251 2 2STHA45C 2STHA55C 2STNA45C 2STNA55C
2 2SAN45152 2SAN45252 2SAN55152 2SAN55252 C
> Packing unit : 1 Easy Temporary Abutment + 1 Abutment Screw.
3 2SAN45153 2SAN45253 2SAN55153 2SAN55253 > For Screw Retained Prosthesis.
4 2SAN45154 2SAN45254 2SAN55154 2SAN55254 > For simpler and speedier chair-side process.
> Vaneerable polymer material.
> Packing unit : 1 Abutment + 1 Abutment Screw. > Temporary restoration for anterior esthetic zone.
Hex N-Hex
> For Screw-Cement or Cement Retained Prosthesis. > Titanium core for strength.
> Solution for anterior esthetic zone. > Connected with the Abutment Screw (2SSHR200).
> Connected with the Abutment Screw (2SSHR100). > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Gold color for more translucent restoration (Hex) and classification with N-Hex. > Tightening torque force : 20 N.cm.

REGENERATIVE SOLUTION
> Select Hex-A or Hex-B according to case. > Fixture level impression.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

COWELL®
> Fixture level impression.

036 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 037


COWELLMEDI HISTORY
Temporary Abutment Abutment Screw
Diameter
D Height Ø2.45 Ø2.15
Type Hex N-Hex 1.2 Hex. 1.2 Hex.
1.2 Hex.
8.5 2SSHR100 2SSHR200
Diameter Ø4.5 Ø4.5
L 2.45 Length D D > Packing unit : 1 Abutment Screw.
Cuff 10 10
> 2SSHR100 : Hybrid Block / Scanbody / Angulated / Milling / Temporary / Meta G UCLA / Plastic UCLA Abutment.
C
1 2STHA45 2STNA45 H > 2SSHR200 : Hybrid S & L Ti-Base / Cemented / Easy Temporary Abutment.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Packing unit : 1 Temporary Abutment + 1 Abutment Screw.
> For Screw-Cement Retained Prosthesis.
> For provisional restoration.
> Connected with the Abutment Screw (2SSHR100).
Hex N-Hex > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 20 N.cm.

REID
> Fixture level impression.

COWELL® IMPLANT SYSTEM


Meta G UCLA Abutment Replica D
D Type Hex N-Hex Diameter
Height Ø4
1.2 Hex.
Diameter Ø4.5 Ø4.5 12 2SRHR001
H
Length
2.45 Cuff 12 12 > Packing unit : 1 Replica.
L
1 2SGH45N 2SGN45N > Mimicking of conical interface of fixture.
> Analog of fixture for working cast.
C 2 2SGH452N 2SGN452N
3 2SGH453N 2SGN453N

> Packing unit : 1 Meta G UCLA Abutment + 1 Abutment Screw.


> For Screw-Cement or Screw Retained Prosthesis.

COWELL® DIGITAL PRODUCTS


Hex N-Hex > Modification to angulated abutment, Customized abutment and telescopic abutment.
> CCM alloy core for precise connection.
> Cast with non-precious metal or gold alloy.
> Connected with the Abutment Screw (2SSHR100).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Fixture level impression.

Plastic UCLA Abutment

COWELL® EXPERT INSTRUMENTS


D
Type Hex N-Hex
1.2
Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
Length
2.45 Cuff 11 11 11 11
L
3 2SPHR001 2SPHW001 2SPNR001 2SPNW001
C
> Packing unit : 1 Plastic UCLA Abutment + 1 Abutment Screw.
> Same purpose of use as the Meta G UCLA Abutment but low accuracy of connection during lab procedure.
> PMMA material.
> Connected with the Abutment Screw (2SSHR100).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex N-Hex > Tightening torque force : Finger light force during wax pattern fabrication, 30 N.cm after casting.
> Fixture level impression.

REGENERATIVE SOLUTION
COWELL®
038 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 039
COWELLMEDI HISTORY
Bite Impression Coping
D Type Hex(Short) Hex(Long) Hex(X-Long)
Prosthetic Procedure II
Diameter Ø4.5 Ø4.5 Ø4.5 Component Selection Guide for Multi S&A Abutment
L
Cuff
Length 2 4 6
C 4.0 2SBIC45S 2SBIC45L 2SBIC45X

> Packing unit : 1 Bite Impression Coping (Inbuilt Guide Pin).


Multi Polishing Protector
> Designed to simultaneously take bite and impression.
> For Closed Tray Impression (Bite Impression).
(Short) (Long) (X-Long) > Tightened with the 1.2 Hex Driver and Torque Wrench.

REID
Hex Multi Cylinder Screw

(Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)


Pick-up Impression Coping

COWELL® IMPLANT SYSTEM


Multi Meta G Multi Plastic Multi Titanium
UCLA Cylinder UCLA Cylinder Cylinder
D Type Hex N-Hex
Diameter
Length / Cuff Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5
14 (Short) / 4 2SIH454S 2SIH554S 2SIH654S 2SIN454S 2SIN554S 2SIN654S
L
14 (Short) / 2 2SIH45S 2SIH55S 2SIH65S 2SIN45S 2SIN55S 2SIN65S

C
16 (Long) / 4 2SIH45L 2SIH55L 2SIH65L 2SIN45L 2SIN55L 2SIN65L

> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (2SISR001SS / 2SISR001SL).
Lab Analog
> For open tray impression.
(Short) (Short) (Long) (Short) (Short) (Long)
> Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
2 Pieces

COWELL® DIGITAL PRODUCTS


Hex N-Hex

Multi Pick-up
Impression Coping Multi Transfer Post

Transfer Post
D
Type Hex N-Hex
Diameter Multi Protection Cap

COWELL® EXPERT INSTRUMENTS


Length / Cuff Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5
L
9 (Short) / 2 2STH45S 2STH55S 2STH65S 2STN45S 2STN55S 2STN65S
11 (Long) / 4 2STH45L 2STH55L 2STH65L 2STN45L 2STN55L 2STN65L
C
> Packing unit : Hex - 1 Transfer Post + 1 Guide Pin (2STH001SS / 2STH001SL)
N-Hex - 1 Transfer Post (Solid Type).
(Short) (Long) (Short) (Long)
> For closed tray impression.
> Connected with the Guide Pin.
2 Pieces 1 Piece > Tightened with the 1.2 Hex Driver and Torque Wrench.
Multi S Abutment Multi A Abutment

Hex N-Hex

REGENERATIVE SOLUTION
COWELL®
Healing
Fixture Cover Screw Abutment

040 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 041


COWELLMEDI HISTORY
Multi S Abutment Diameter Ø4.5 Ø5.5
Multi Protection Cap
Multi S & A
Abutment Diameter Ø4.5 Ø5.5
Length 2 2 D
Cuff Diameter
D
Height Ø5.2 Ø6.2
1 2SMS451 2SMS551
L H
5 2SMPC45 2SMPC55
2 2SMS452 2SMS552
C
1 Piece 2SMS453 2SMS553 > Packing unit : 1 Multi Protection Cap.
3
> Protection from cheek and tongue for gingival healing period.
4 2SMS454 2SMS554 > Gingival retraction for prosthodontic margin of abutment.
5 2SMS455 2SMS555 > Alternative usage for sub-structure of temporary prosthesis.

> Packing unit : 1 Multi S Abutment.


> For Screw-Retained Prosthesis.
> Titanium base for the cylinders.

REID
> Gold color for more translucent restoration.
> Integrated with screw and abutment.
> Library available for EXOCAD®, 3Shape® & Others.
> Use the S Holder for more stable position.
> Tightened with the S Machine & S Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.

COWELL® IMPLANT SYSTEM


Multi A Abutment Type Hex
1.2 Hex.
Multi Pick-up Impression Coping
Diameter(Angle) Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°)
D
L Length D
A 2.15 Cuff 2 2 2 2 Type Hex N-Hex
C 2 Multi S & A
2SMAH45152 Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
3 2SMAH45303 2SMAH55153 2SMAH55303 Diameter
2SMAH45153 L Length Ø4.65 Ø5.65 Ø4.65 Ø5.65
4 2SMAH45154 2SMAH45304 2SMAH55154 2SMAH55304 14.8 2SMIH45 2SMIH55 2SMIN45 2SMIN55
5 2SMAH55155 2SMAH55305
2 Pieces > Packing unit: 1 Multi Pick-up Impression Coping + 1 Guide Pin (2SMGP012).
Hex N-Hex
Type N-Hex > For open tray impression.
> Connected with the Guide Pin.
Diameter(Angle) Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°) > Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex N-Hex

COWELL® DIGITAL PRODUCTS


Length > Tightening torque force: 12~15 N.cm.
Cuff 2 2 2 2
2 2SMAN45152
3 2SMAN45153 2SMAN45303 2SMAN55153 2SMAN55303
4 2SMAN45154 2SMAN45304 2SMAN55154 2SMAN55304
5 2SMAN55155 2SMAN55305
> Packing unit: 1 Multi A Abutment + 1 Abutment Screw.
> For Screw-Retained Prosthesis.
> Titanium base for the cylinders.
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Use the A Holder for more stable position. Multi Transfer Post

COWELL® EXPERT INSTRUMENTS


> Connected with the Abutment Screw (2SSHR300 : ★ / 2SSHR400 : ●). Type Hex N-Hex
> Tightened with the 1.2 Hex Driver and Torque Wrench. D
Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
> Tightening torque force: 30 N.cm.
Diameter
> Use the Multi Scanbody for digital flow. L Length Ø4.5 Ø5.5 Ø4.5 Ø5.5
> Abutment level impression. 8.5 2SMTH45 2SMTH55 2SMTN45 2SMTN55

Abutment Screw > Packing unit: 1 Multi Transfer Post + 1 Guide Pin (2SMTHS100).
1.2 Hex. Height > For closed tray impression.
Diameter 7.5 6.5 > Connected with the Guide Pin.
Hex N-Hex
D
2.15 2SSHR300 2SSHR400 > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.
> Packing unit: 1 Abutment Screw.
H > To connect the Multi A Abutment.
> Tightened with the 1.2 Hex Driver and Torque Wrench.

REGENERATIVE SOLUTION
COWELL®
042 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 043
COWELLMEDI HISTORY
Multi Lab Analog Multi Titanium Cylinder Type Hex N-Hex
D Multi S & A Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
L 1.2 Hex.
Diameter Ø4.5 Ø5.5
Length Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
L Length
2 2SMA45 2SMA55 2.25 Cuff 8.5 8.5 8.5 8.5
> Packing unit : 1 Multi Lab Analog. 0.5 2STCH45 2STCH55 2STCN45 2STCN55
C
> Replacement of abutment shape in working cast. D
> Choose by abutment size. > Packing unit : 1 Multi Titanium Cylinder + 1 Cylinder Screw.
> For Screw, Cement or Screw-Cement Retained Prosthesis.
> Connected with the Cylinder Screw.
Hex N-Hex > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

REID
COWELL® IMPLANT SYSTEM
Multi Meta G UCLA Cylinder Type Hex N-Hex Multi Cylinder Screw
Diameter
Multi S & A
Ø4.5 Ø5.5 Ø4.5 Ø5.5 Height Ø2.25
Abutment Diameter
1.2 Hex. 1.2 Hex.
Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5 5 2SMCS100
L Length
2.25 Cuff 10.9 10.9 10.9 10.9 D > Packing unit : 1 Multi Cylinder Screw.
0.5 2SCCH45 2SCCH55 2SCCN45 2SCCN55 > Connected with the Meta G UCLA, Plastic UCLA and Titanium Cylinder.
H > Tightened with the 1.2 Hex Driver and Torque Wrench.
C
D > Packing unit : 1 Multi Meta G UCLA Cylinder + 1 Multi Cylinder Screw. > Tightening torque force : 30 N.cm.
> For Screw, Cement or Screw-Cement Retained Prosthesis.
> Modification to various types of abutments.
> CCM alloy core for precise connection.
Hex N-Hex
> Cast with non-precious metal or gold alloy.

COWELL® DIGITAL PRODUCTS


> Connected with the Multi Cylinder Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

Multi Plastic UCLA Cylinder Type Hex N-Hex Multi Polishing Protector Type Hex

COWELL® EXPERT INSTRUMENTS


Multi S & A Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5 D Abutment Diameter Ø4.5 Ø5.5
Diameter
1.2 Hex.
Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5 L Length Ø4.5 Ø5.5
Length 2 2SMPP45 2SMPP55
Cuff 11.5 11.5 11.5 11.5
L
2.25 0.5 2SMPH45 2SMPH55 2SMPN45 2SMPN55
> Packing unit : 1 Protector.
> Packing unit : 1 Multi Plastic UCLA Cylinder + 1 Multi Cylinder Screw. > For polishing work during lab procedure.
C
> For Screw, Cement or Screw-Cement Retained Prosthesis.
D
> Same purpose of use as the Meta G UCLA Cylinder but low accuracy of connection.
> PMMA material.
> Connected with the Multi Cylinder Screw.
Hex N-Hex > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

REGENERATIVE SOLUTION
COWELL®
044 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 045
COWELLMEDI HISTORY
Multi Holder Prosthetic Procedure III
H
Component Selection Guide for Lock Abutment
Type
Height Hand
20 KMHS01
S Holder > Packing unit : 1 Holder.
> To position the Multi S Abutment more stably.

H
Type
Height Hand
Lock Cylinder Screw

REID
20 KMHA01
A Holder
> Packing unit : 1 Holder.
> To position the Multi A Abutment more stably.
1.2 Hex Driver

Lock Meta G UCLA Cylinder Lock Titanium Cylinder

COWELL® IMPLANT SYSTEM


Lock Lab Analog

COWELL® DIGITAL PRODUCTS


Multi S Machine Driver Type
Height Machine
H 27.5 KMMSD21L
Lock Pick-up Impression Coping
> Packing unit: 1 Multi S Machine Driver.
> To install the Multi S Abutment by machine.

Lock Protection Cap

Multi S Ratchet Driver

COWELL® EXPERT INSTRUMENTS


Type
Height Ratchet
H
22 KRMSD15L

> Packing unit: 1 Multi S Ratchet Driver.


> To install the Multi S Abutment by hand.
Lock Abutment

REGENERATIVE SOLUTION
Healing
Fixture Cover Screw Abutment

COWELL®
046 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 047
COWELLMEDI HISTORY
Lock Abutment Diameter Ø4.5 Lock Lab Analog
Diameter
D Length
2.15 D Length Ø4.5
Cuff
L
L 0.5 2SLA400 2.15 2SLA45
C
1 2SLA410 > Packing unit : 1 Lock Lab Analog.
2 2SLA420
> Replacement of abutment shape in working cast.
> Connected with the Guide Pin.
3 2SLA430 > Tightened with the 1.2 Hex Driver and Torque Wrench.
4 2SLA440

> Packing unit : 1 Lock Abutment.


> For Screw-Retained Prosthesis.
> Titanium base for cylinder.
> Gold color for more translucent restoration.

REID
> Integrated with screw and abutment.
> Tightened with the Lock Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.

COWELL® IMPLANT SYSTEM


Lock Meta G UCLA Cylinder Diameter
Lock Protection Cap Diameter
Ø4.5 Height Ø4.5
Height 1.2 Hex.
D
2SLP45 11.2 2SLCH45
4.3
H 2.3 > Packing unit : 1 Lock Meta G UCLA Cylinder + 1 Cylinder Screw.
H > Packing unit : 1 Lock Protection Cap.
> Protection from cheek and tongue for gingival healing period. > For Screw, Cement or Screw-Cement Retained Prosthesis.
> Gingival retraction for prosthodontic margin of abutment. > Modification to various types of abutments.
D > CCM alloy core for precise connection.
> Cast with non-precious metal or gold alloy.
> Connected with the Cylinder Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

COWELL® DIGITAL PRODUCTS


Lock Titanium Cylinder Diameter
Lock Pick-up Impression Coping Ø4.5

COWELL® EXPERT INSTRUMENTS


Height
1.2 Hex.
Diameter 10 2SLTH45
Length Ø4.5
16 2SLIH45
H 2.3 > Packing unit : 1 Lock Titanium Cylinder + 1 Cylinder Screw.
L > For Screw, Cement or Screw-Cement Retained Prosthesis.
> Packing unit : 1 Lock Pick-up Impression Coping + 1 Guide Pin (2SLIH45S). > Connected with the Cylinder Screw.
> For open tray impression. D > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
D

REGENERATIVE SOLUTION
COWELL®
048 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 049
COWELLMEDI HISTORY
Lock Cylinder Screw
1.2 Hex. Height
Diameter
Ø2.3
Prosthetic Procedure IV
4.8 2SLCS200 Component Selection Guide for Absolute Abutment
D
> Packing unit : 1 Cylinder Screw.
H > Connected with the CCM Cylinder or Titanium Cylinder.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

(Crown) (Bridge)

REID
Absolute Plastic Coping

COWELL® IMPLANT SYSTEM


Absolute Lab Analog
Lock Ratchet Driver
H
Type
Height Ratchet
14.2 KRLRD18

H
28.5 KRLRD28
> Packing unit : 1 Lock Ratchet Driver. Absolute Impression Cap
> To install the Lock Abutment by hand.

COWELL® DIGITAL PRODUCTS


Absolute Protection Cap

COWELL® EXPERT INSTRUMENTS


Absolute Abutment

Healing
Fixture Cover Screw Abutment

REGENERATIVE SOLUTION
COWELL®
050 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 051
COWELLMEDI HISTORY
Absolute Abutment
Diameter Ø4.5 Ø5.5 Prosthetic Procedure V
D Length
Cuff 4 5.5 7 4 5.5 7
Component Selection Guide for Straight Abutment
L
1 2SAC4514 2SAC4515 2SAC4517 2SAC5514 2SAC5515 2SAC5517
2 2SAC4524 2SAC4525 2SAC4527 2SAC5524 2SAC5525 2SAC5527
C
3 2SAC4534 2SAC4535 2SAC4537 2SAC5534 2SAC5535 2SAC5537
1.2 Hex Driver
4 2SAC4544 2SAC4545 2SAC4547 2SAC5544 2SAC5545 2SAC5547
5 2SAC4554 2SAC4555 2SAC4557 2SAC5554 2SAC5555 2SAC5557

Diameter Ø6.5
> Packing unit : 1 Absolute Abutment + 1 Production Cap.
Length
> For Cement Retained Prosthesis.

REID
Cuff 4 5.5 7 > Cutting surface for anti-rotation of prosthesis.
1 2SAC6514 2SAC6515 2SAC6517 > Integrated with the Screw and Abutment. Straight Abutment
> Tightened with the 1.2 Hex Driver and Torque Wrench.
2 2SAC6524 2SAC6525 2SAC6527 > Tightening torque force : 30 N.cm.
3 2SAC6534 2SAC6535 2SAC6537 > Abutment level impression.
4 2SAC6544 2SAC6545 2SAC6547
5 2SAC6554 2SAC6555 2SAC6557

COWELL® IMPLANT SYSTEM


Absolute Protection Cap Abut. Diameter Ø4.5 Ø5.5 Ø6.5
D
Diameter Ø5.0 Ø6.0 Ø7.0 Healing
Height Fixture Fixture Cover Screw Abutment
H 6 2SHPC454 2SHPC554 2SHPC654
7.5 2SHPC455 2SHPC555 2SHPC655
9 2SHPC457 2SHPC557 2SHPC657
> Packing unit : 1 Absolute Protection Cap .
> Protection from cheek and tongue for gingival healing period. Straight Abutment
> Gingival retraction for prosthodontic margin of abutment.
> Alternative usage for sub-structure of temporary prosthesis. D Diameter Ø3.5 Ø4.5
Length
Cuff 8 8

COWELL® DIGITAL PRODUCTS


Absolute Impression Cap 7 5.5
4
L 0.5 2SSCM308 2SSCR408
Abut. Diameter
Abut. Dia. Ø4.5 Ø5.5 Ø6.5
D 1 2SSCM318 2SSCR418
Diameter C
Height Ø5.5 Ø6.5 Ø7.5
2 2SSCM328 2SSCR428
H 10.3 2SIC45 2SIC55 2SIC65
3 2SSCM338 2SSCR438
> Packing unit : 1 Absolute Impression Cap. 4 2SSCM348 2SSCR448
> Confirm locking with abutment by rotation of clockwise and anti-clockwise direction.
> Packing unit : 1 Straight Abutment.
> For Cement Retained Prosthesis.
Absolute Lab Analog > Integrated with screw and abutment.
Abut. Diameter Ø4.5 Ø5.5 Ø6.5
> Tightened with the Shoulder Driver.
Diameter Ø4.5 Ø5.5 Ø6.5 > Tightening torque force : 30 N.cm.
D Length
> Direct impression.

COWELL® EXPERT INSTRUMENTS


L
4.1 2SHLA454 2SHLA554 2SHLA654
5.6 2SHLA455 2SHLA555 2SHLA655
7.1 2SHLA457 2SHLA557 2SHLA657

> Packing unit : 1 Absolute Lab Analog.


> Replacement of abutment shape in working cast.
> Choose according to width and length of abutment. Shoulder Driver

H Diameter
Absolute Plastic Coping (Burn Out Cylinder) Height Ø4.5
D 19 KRR19L
Type Crown Bridge
> Packing unit : 1 Driver.
H H Abut. Diameter Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5 > To install the Straight Abutment.
Diameter
Ø5.1 Ø6.1 Ø7.1 Ø5.1 Ø6.1 Ø7.1

REGENERATIVE SOLUTION
Height
D
10 2SHBC45 2SHBC55 2SHBC65 2SHBB45 2SHBB55 2SHBB65

> Packing unit : 1 Absolute Plastic Coping.

COWELL®
Crown Bridge > Connected with the Lab Analog.
> Burn out and casting for metal framework.

052 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 053


COWELLMEDI HISTORY
Prosthetic Procedure VI Sonator S Abutment
Block-out
Black
Processing
Outer Cap Spacer Male H-Type Inner Caps
Component Selection Guide for Sonator Abutment
2.25mm

Ø5.4
Bule : 10N Pink :15N White : 22N
Black Carrier
Block-out Processing
Outer Cap Spacer Male

Diameter Ø4.0
Cuff

REID
Length 1 2 3 4 5 6
1.5 SONS401 SONS402 SONS403 SONS404 SONS405 SONS406
> Packing unit : Sonator S Abutment + Carrier + 3 H-Type Inner Caps + Outer Cap + Block-out Spacer + Black Processing Male.
> For Implant Supported Over-denture Prosthesis.
D Ratchet Driver
> Stable with low vertical height.
L > 6 kinds of the Inner Caps give various holding force (Both, H and NH-Type Inner Caps are used for the Sonator S Abutment).
H-Type Inner Caps NH-Type Inner Caps > Path compensation up to 20° based on 2 implants.
C
> Carrier : Used for delivery of the abutment.
> Tightened with the Sonator S Ratchet Driver and Torque Wrench.

COWELL® IMPLANT SYSTEM


> Tightening torque force : 30 N.cm.
> Abutment level impression.

Sonator A Abutment
Black
Block-out Processing
Outer Cap Spacer Male NH-Type Inner Caps

2.25mm
Analog

COWELL® DIGITAL PRODUCTS


Ø5.4
Red : 10N Orange : 15N Green : 22N

Diameter Ø4.0
Carrier
Length 1.5 3.0
Impression Coping Cuff 3 3
Angle
15° SONA415 SONA430

> Packing unit : Sonator A Abutment + Abutment Screw + Carrier + 3 NH-Type Inner Caps + Outer Cap
D 1.2 Hex Driver + Block-out Spacer + Black Processing Male.
> For Implant Supported Over-denture Prosthesis.

COWELL® EXPERT INSTRUMENTS


A
> Stable with low vertical height.
1.2 Hex. > 6 kinds of Inner Caps give various holding force (Both, H and NH-Type Inner Caps are used for Sonator A Abutment).
L > Path compensation up to 40° based on 2 Implants.
C 2.15
> Connected with the Abutment Screw (2SSHR300).
Sonator S Abutment Sonator A Abutment
> Carrier : Used for delivery of the abutment.
> Tightened with the 1.2 Hex Driver and Torque wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.

Abutment Screw
1.2 Hex.

Healing
Fixture Cover Screw

REGENERATIVE SOLUTION
Abutment D
Diameter
Height Ø2.15
H 7.5 2SSHR300

COWELL®
054 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 055
COWELLMEDI HISTORY
Outer Cap Sonator Lab Analog
Diameter Diameter
D
Black Processing Male Height Ø5.4 Length Ø4
D
2.25 SONOC01 8.8 SONLA04
H
> Packing unit : 2 Outer Caps and 2 Black Processing Males. > Packing unit : 4 Lab Analogs.
> Black Processing Male: Inserted and removed with the I&R Driver. > Replacement of abutment shape in working cast.
L

REID
H-Type Inner Cap Code SONIC01
> Packing unit : 3 Block-out Spacers + 3 Inner Caps (1 Blue, 1 Pink and 1 White).
Block-out
> Path compensation up to 20° based on 2 implants.
Spacer Inner Cap > Mainly used for the Sonator S Abutment.
> Inner Caps: Inserted and removed with the I&R Driver.

COWELL® IMPLANT SYSTEM


Bule : Pink : White : Sonator S Ratchet Driver
Retention Force Retention Force Retention Force
About 10N About 15N About 22N H
Type
Height Ratchet
18 SONRD19L
> Used to tighten and untighten the Sonator S Abutment.

NH-Type Inner Cap Code

COWELL® DIGITAL PRODUCTS


SONIC02
> Packing unit : 3 Block-out Spacers + 3 Inner Caps (1 Red, 1 Orange and 1 Green).
> Non-humped design.
Block-out
Spacer Inner Cap > Path compensation up to 40° based on 2 implants.
> Mainly used for the Sonator A Abutment.
> Inner Caps : Inserted and removed with the I&R Driver.

Red : Orange : Green :


Retention Force Retention Force Retention Force
About 10N About 15N About 22N
I & R Driver
Height 95.4

COWELL® EXPERT INSTRUMENTS


SONIR002

For Removal For Insertion

Sonator Impression Coping > Used to insert and remove the Inner Caps and Block Processing Male.
Diameter
Length Ø4.8
D
Black Processing Male
3 SONIP04

L
> Packing unit : 4 Impression Copings and 4 Black Processing Males.
> Connected over the Sonator Abutment after placing the Block-out Spacer.
> For close tray impression.

REGENERATIVE SOLUTION
COWELL®
056 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 057
COWELLMEDI HISTORY
Prosthetic Procedure VII Ball Abutment
Outer Cap Block-out Spacer
Diameter
Length
Ø4.0
4
Cuff
Component Selection Guide for Ball Abutment 1 2SBAT414R
2.4mm

Ø3.4 2 2SBAT424R
3 2SBAT434R
4 2SBAT444R
5 2SBAT454R
Red : 10N Orange : 15N Green : 20N

Ball Inner Cap > Packing unit : 1 Ball Abutment + 3 Inner Caps (1 per each colour) + 1 Block-out Spacer + 1 Outer Cap.
D > For Implant Supported Over-denture Prosthesis.
> Tightened with the Ball Driver and Torque Wrench.

REID
L
> Tightening torque force : 30 N.cm.
Ball Outer Cap Block-out Spacer > Direct impression.
C

Ball Abutment

Red : 10N Orange : 15N Green : 20N

COWELL® IMPLANT SYSTEM


Ball Inner Cap Ball Outer Cap Diameter
D Length Ø3.4
2.4 BATC003C
L
> Packing unit : 2 Outer Caps.

Ball Inner Cap


Block-out Ball Inner Cap
Spacer BATC003I
> Packing unit: 2 Block-out Spacers + 6 Inner Caps (2 per each color).
Ball Analog > Retention force: Red 10N, Orange 15N & Green 20N.
Red : 10N Orange : 15N Green : 20N

COWELL® DIGITAL PRODUCTS


Ball Analog
D
Diameter
Length Ø4.0
L
4 SBAL400

> Packing unit : 4 Lab Analogs.


> Replacement of abutment shape in working cast.

Ball Abutment

COWELL® EXPERT INSTRUMENTS


Ball Driver
Type
H Height Ratchet
19 KRB19L
> Packing unit : 1 Ball Driver. *Extra Product
> Used with the Torque Wrench to tighten and untighten the Ball Abutment.
Healing
Fixture Cover Screw Abutment

I&R Driver Height 100


KBIR01

REGENERATIVE SOLUTION
For Removal For Insertion

COWELL®
> Packing unit : 1 I&R Driver.
> Used to insert and remove the Inner Caps into and out of the Outer Cap.

058 INNO-SUBMERGED IMPLANT INNO-SUBMERGED IMPLANT 059


COWELLMEDI HISTORY
INNO SUBMERGED NARROW IMPLANT (Sub-N.)
System Flow

Fixture Abutment Impression

REID
065p 065p 065p 066p 066p 067p 067p

Fixture Level
Procedure I

Impression
Prosthetic

Replica Pick-up Impression Coping Transfer Post

COWELL® IMPLANT SYSTEM


Cemented Angulated Temporary Meta G UCLA

Hex 2.1

063p 063p 070p 070p 070p 071p 071p 071p 072p 072p

COWELL® DIGITAL PRODUCTS


Procedure II
Prosthetic

Length Multi Multi Impression Multi Multi Multi Meta G Multi Plastic Multi Titanium Multi Polishing
8 / 10 / 12 / 14mm Protection Cap Coping Transfer Post Lab Analog ULCA Cylinder UCLA Cylinder Cylinder Protector
Multi S Multi A

Diameter
Ø3.1 / 3.3

Abutment Level
Impression

COWELL® EXPERT INSTRUMENTS


074p
Procedure III
Prosthetic

Direct
Impression

Straight

REGENERATIVE SOLUTION
COWELL®
060 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 061
COWELLMEDI HISTORY
INNO Submerged Pre-Mount > Packing unit : 1 Fixture + 1 Cover Screw + 1 Mount.

Narrow Implant (Sub-N.)


Diameter
Ø3.1
Length 8 10 12 14

8 SR3108NS
L
10 SR3110NS
Submerged Fixture 12 SR3112NS
SUB-N. ୔ Note
HEXAGON Surface Treatment : SLA-SH® 14 SR3114NS D
> The INNO Sub. Narrow System is not compatible with
SYSTEM > Interchangeable with hexagonal morse tapered fixture. the INNO Submerged System as hexagon size is different.

REID
> Internal hex connection (Taper 11°/ Hex 2.1).
Diameter
Ø3.3
Length 8 10 12 14

Hex 2.1 8 SR3308NS


10 SR3310NS L

12 SR3312NS
14 SR3314NS

COWELL® IMPLANT SYSTEM


D

Fixture Mount
Length 5.4
L
RSM001
> Packing unit : 1 Mount + 1 Mount Screw.
L > Tightened with the 1.2 Hex Driver.
> Tightening torque force : 5~10 N.cm.

COWELL® DIGITAL PRODUCTS


Cover Screw
D Diameter
Ø2.85 Ø3.25 Ø3.6
D Length
L 1.7 RCS000
2.7 RCS001
No-Mount > Packing unit : 1 Fixture + 1 Cover Screw.
3.7 RCS002

Diameter > Packing unit : 1 Cover Screw.


Ø3.1
Length > To seal the conical interface of fixture.
> The longer the Cover Screw for deeply inserted fixture.

COWELL® EXPERT INSTRUMENTS


> Tightened with the 1.2 Hex Driver.
8 SR3108NSM 8 10 12 14
> Tightening torque force : 5~10 N.cm.
L
10 SR3110NSM
12 SR3112NSM Healing Abutment Diameter Ø3.5 Ø4.5
14 SR3114NSM D Length
D Cuff 1 2 1 2
0.5 HR3501
L
C 1 HR3511 HS4511N
Diameter
Ø3.3 2 HR3522 HS4522N
Length
3 HR3532 HS4532N

8 SR3308NSM 8 10 12 14 4 HR3542 HS4542N

10 SR3310NSM L 5 HS4552N

REGENERATIVE SOLUTION
12 SR3312NSM 7 HS4572N

14 SR3314NSM D
> Packing unit : 1 Abutment.
> For remodeling gingival contour during soft tissue healing.

COWELL®
> Select according to gingival height and abutment type.
> Tightened with the 1.2 Hex Driver.
> Tightening torque force : 5~10 N.cm.

062 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 063


COWELLMEDI HISTORY
Prosthesis Procedure I Cemented Abutment
1.2 Hex.
Type Hex N-Hex

Components Selection Guide for Cemented and UCLA Abutment D Diameter Ø4.5 Ø4.5
2.25 Length
L Cuff 4 5.5 7 4 5.5 7

C
1 SCH4514N SCH4515N SCH4517N SCN4514N SCN4515N SCN4517N
2 SCH4524N SCH4525N SCH4527N SCN4524N SCN4525N SCN4527N
3 SCH4534N SCH4535N SCH4537N SCN4534N SCN4535N SCN4537N
4 SCH4544N SCH4545N SCH4547N SCN4544N SCN4545N SCN4547N
2.25 Hex N-Hex 5 SCH4554N SCH4555N SCH4557N SCN4554N SCN4555N SCN4557N
> Packing unit : 1 Cemented Abutment + 1 Abutment Screw.
> For Screw-Cement or Cement Retained Prosthesis.

REID
> Cutting surface for anti-rotation of prosthesis.
Abutment Screw > Gold color for more translucent restoration (Hex) and classification with N-Hex.
> Library available for EXOCAD®, 3Shape® & Others.
> Connected with the Abutment Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work.
> Fixture level impression.
(Hex) (N-Hex) (Hex) (Hex) (N-Hex) (Hex) (N-Hex)

COWELL® IMPLANT SYSTEM


Cemented Angulated Temporary Meta G UCLA
Abutment Abutment Abutment Abutment Angulated Abutment Type Hex

15° / 25° Diameter(Angle) Ø4.5(15°) Ø4.5(25°)


1.2 Hex. Length
Cuff 8 8
L
2.25
1 SAH45151NA SAH45251NA
2 SAH45152NA SAH45252NA
C
3 SAH45153NA SAH45253NA
D 4 SAH45154NA SAH45254NA

> Packing unit : 1 Abutment + 1 Abutment Screw.


> For Screw-Cement or Cement Retained Prosthesis.
Hex > Solution for anterior esthetic zone.
Replica

COWELL® DIGITAL PRODUCTS


> Gold color for esthetics.
> Connected with the Abutment Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Fixture level impression.

(Hex) (N-Hex) (Hex) (N-Hex)


Pick-up Impression Coping Transfer Post Temporary Abutment

COWELL® EXPERT INSTRUMENTS


D Type Hex N-Hex
1.2 Hex.
Diameter Ø4.5 Ø4.5
Length
Cuff 10 10
2.25
L 1 STHA45N STNA45N
Open or Closed Tray Impression C > Packing unit : 1 Abutment + 1 Abutment Screw.
> For Screw-Cement Retained Prosthesis.
> For provisional restoration.
> Connected with the Abutment Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex N-Hex > Tightening torque force : 20 N.cm.

Healing

REGENERATIVE SOLUTION
Fixture Cover Screw Abutment

COWELL®
064 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 065
COWELLMEDI HISTORY
Meta G UCLA Abutment Type Hex N-Hex Pick-up Impression Coping Type Hex N-Hex
D
Diameter Ø4.5 Ø4.5 Diameter
D 1.2 Hex. Length / Cuff Ø4.5 Ø4.5
Length
Cuff 12 12 14 (Short) / 2 SIH45SN SIN45SN
2.25 L
1 SGH45N SGN45N 16 (Long) / 4 SIH45LN SIN45LN
2 Pieces
L 2 SGH452N SGN452N
C
3
> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin.
SGH453N SGN453N
C > For open tray impression.
> Packing unit : 1 Abutment + 1 Abutment Screw. (Short) (Long) (Short) (Long)
> Connected with the Guide Pin (SIS001SN / SIS001LN).
> For Screw Retained Prosthesis. > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Modification to angulated abutment, customized abutment and telescopic abutment.
Hex N-Hex > CCM alloy core for precise connection.
Hex N-Hex

REID
> Cast with non-precious metal or gold alloy.
> Connected with the Abutment Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
> Fixture level impression.

COWELL® IMPLANT SYSTEM


Abutment Screw Transfer Post
D
1.2 Hex.
Diameter
Length 2.25
L Type Hex N-Hex
D 10.2 SSHR100N
Diameter
Length / Cuff Ø4.5 Ø4.5
> Packing unit : 1 Abutment Screw. C
L > Tightened with the 1.2 Hex Driver and Torque Wrench. 9 (Short) / 2 STH45SN STN45SN
> Tightening torque force : 30 N.cm. 11 (Long) / 4 STH45LN STN45LN
(Short) (Long) (Short) (Long)
> Packing unit : 1 Transfer Post + 1 Guide Pin (Hex) / 1 Transfer Post (N-Hex, Solid).
> For closed tray impression.
> Connected with the Guide Pin (STS001SN / STS001LN).
> Tightened with the 1.2 Hex Driver and Torque Wrench.

COWELL® DIGITAL PRODUCTS


Hex N-Hex

2 Pieces 1 Piece

Replica D

COWELL® EXPERT INSTRUMENTS


Diameter
Height Ø4
H 12.1 SRHR001N
> Packing unit : 1 Replica.
> Mimicking of conical interface of fixture.
> Analog of fixture for working cast.

REGENERATIVE SOLUTION
COWELL®
066 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 067
COWELLMEDI HISTORY
Prosthesis Procedure II Multi S Abutment Diameter Ø4.5
Length 2
Component Selection Guide for Multi S&A Abutment D Cuff
1 SMS451N
L

C 2 SMS452N
1 Piece 3 SMS453N

4 SMS454N

Multi Polishing Protector > Packing unit : 1 Multi S Abutment.


> For Screw-Retained Prosthesis.
> Titanium base for the cylinders.
> Gold color for more translucent restoration.
> Integrated with screw and abutment.

REID
Multi Cylinder Screw > Library available for EXOCAD®, 3Shape® & Others.
> Use the S Holder for more stable position.
> Tightened with the S Machine & S Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.

(Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)

COWELL® IMPLANT SYSTEM


Multi Meta G Multi Plastic Multi Titanium
UCLA Cylinder UCLA Cylinder Cylinder Multi A Abutment Type Hex
Diameter(Angle) Ø4.5(15°) Ø4.5(30°)
1.2 Hex.
Length 2 2
D Cuff
L
A 1.95 2 SMAH45152BN

C 3 SMAH45153BN SMAH45303BN
4 SMAH45154BN SMAH45304BN

Lab Analog Type N-Hex


Diameter(Angle) Ø4.5(15°) Ø4.5(30°)
Hex N-Hex 2 Pieces Length
Cuff
2 2

COWELL® DIGITAL PRODUCTS


2 SMAN45152NB
3 SMAN45153NB SMAN45303NB
4 SMAN45154NB SMAN45304NB

Multi Pick-up > Packing unit : 1 Multi A Abutment + 1 Abutment Screw.


Impression Coping Multi Transfer Post
> For Screw-Retained Prosthesis.
> Titanium base for the cylinders.
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & Others.
> Use the A Holder for more stable position.
> Connected with the Abutment Screw ( SSHR200N : ★ / SSHR300N : ● ).
Multi Protection Cap > Tightened with the 1.2 Hex Driver and Torque Wrench.

COWELL® EXPERT INSTRUMENTS


> Tightening torque force : 30 N.cm.
> Abutment level impression.

Abutment Screw
1.2 Hex. Height
Multi S Abutment Multi A Abutment Diameter 8.7 9.3
Ø1.95 SSHR200N SSHR300N
D

> Packing unit: 1 Abutment Screw.


H > To connect the Multi A Abutment.
> Tightened with the 1.2 Hex Driver and Torque Wrench.

REGENERATIVE SOLUTION
COWELL®
Healing
Fixture Cover Screw Abutment

068 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 069


COWELLMEDI HISTORY
Multi Protection Cap Multi Lab Analog Multi S & A
Multi S & A D Abutment Diameter Ø4.5
Abutment Diameter Ø4.5
D Diameter
Diameter L Length Ø4.5
Height Ø5.2
H 2 2SMA45
5 2SMPC45

> Packing unit : 1 Multi Protection Cap. > Packing unit : 1 Multi Lab Analog.
> Protection from cheek and tongue for gingival healing period. > Replacement of abutment shape in working cast.
> Gingival retraction for prosthodontic margin of abutment.
> Alternative usage for sub-structure of temporary prosthesis.

REID
COWELL® IMPLANT SYSTEM
Multi Pick-up Impression Coping Multi Meta G UCLA Cylinder
D Type Hex N-Hex
Type Hex N-Hex
1.2 Hex. Multi S & A
Multi S & A Abutment Diameter Ø4.5 Ø4.5
Abutment Diameter Ø4.5 Ø4.5
L Diameter Ø4.5 Ø4.5
Diameter
Length Ø4.65 Ø4.65 2.25
L Length
Cuff 10.9 10.9
14.8 2SMIH45 2SMIN45
C 0.5 2SCCH45 2SCCN45
> Packing unit: 1 Multi Pick-up Impression Coping + 1 Guide Pin (2SMGP012). D
> For open tray impression. > Packing unit : 1 Multi Meta G UCLA Cylinder + 1 Multi Cylinder Screw.
> Connected with the Guide Pin. > For Screw, Cement or Screw-Cement Retained Prosthesis.
> Tightened with the 1.2 Hex Driver and Torque Wrench. Hex N-Hex > Modification to various types of abutments.
Hex N-Hex > Tightening torque force: 12~15 N.cm. > CCM alloy core for precise connection.

COWELL® DIGITAL PRODUCTS


> Cast with non-precious metal or gold alloy.
> Connected with the Multi Cylinder Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

Multi Transfer Post


Multi Plastic UCLA Cylinder
Type Hex N-Hex

COWELL® EXPERT INSTRUMENTS


D Type Hex N-Hex
Multi S & A
Abutment Diameter Ø4.5 Ø4.5 Multi S & A
1.2 Hex. Abutment Diameter Ø4.5 Ø4.5
L Diameter
Height Ø4.5 Ø4.5
Diameter Ø4.5 Ø4.5
L
8.5 2SMTH45 2SMTN45 2.25 Length
Cuff 11.5 11.5

> Packing unit: 1 Multi Transfer Post + 1 Guide Pin (2SMTHS100). 0.5 2SMPH45 2SMPN45
C
> For closed tray impression.
Hex N-Hex > Connected with the Guide Pin.
D > Packing unit : 1 Multi Plastic UCLA Cylinder + 1 Multi Cylinder Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench. > For Screw, Cement or Screw-Cement Retained Prosthesis.
> Tightening torque force: 12~15 N.cm. > Same purpose of use as the Meta G UCLA Cylinder but low accuracy of connection.
Hex N-Hex
> PMMA material.
> Connected with the Multi Cylinder Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

REGENERATIVE SOLUTION
COWELL®
070 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 071
COWELLMEDI HISTORY
Multi Titanium Cylinder Multi Holder
Type Hex N-Hex
1.2 Hex.
Multi S & A
Abutment Diameter Ø4.5 Ø4.5 H
L Diameter Ø4.5 Ø4.5 Type
2.25 Hand
Height
Length
Cuff 8.5 8.5
C 20 KMHS01
0.5 2STCH45 2STCN45
D S Holder > Packing unit : 1 Holder.
> Packing unit : 1 Multi Titanium Cylinder + 1 Cylinder Screw. > To position the Multi S Abutment more stably.
> For Screw, Cement or Screw-Cement Retained Prosthesis.
Hex N-Hex > Connected with the Cylinder Screw. H
> Tightened with the 1.2 Hex Driver and Torque Wrench. Type
> Tightening torque force : 30 N.cm. Height Hand

REID
20 KMHA01
A Holder
> Packing unit : 1 Holder.
> To position the Multi A Abutment more stably.
1.2 Hex Driver

COWELL® IMPLANT SYSTEM


Multi Cylinder Screw
Diameter
Height Ø2.25
1.2 Hex.
5 2SMCS100

D > Packing unit : 1 Multi Cylinder Screw.


> Connected with the Meta G UCLA, Plastic UCLA and Titanium Cylinder.
H > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

Multi S Machine Driver

COWELL® DIGITAL PRODUCTS


Type
Height Machine
H 27.5 KMMSD21L

> Packing unit: 1 Multi S Machine Driver.


> To install the Multi S Abutment by machine.

Multi Polishing Protector Type Hex Multi S Ratchet Driver


Type

COWELL® EXPERT INSTRUMENTS


Multi S & A
Ø4.5 Height Ratchet
D Abutment Diameter H
Diameter
Ø4.5 22 KRMSD15L
L Length
2 2SMPP45 > Packing unit: 1 Multi S Ratchet Driver.
> To install the Multi S Abutment by hand.
> Packing unit : 1 Protector.
> For polishing work during lab procedure.

REGENERATIVE SOLUTION
COWELL®
072 INNO-SUB. NARROW IMPLANT INNO-SUB. NARROW IMPLANT 073
COWELLMEDI HISTORY
Prosthesis Procedure III
Component Selection Guide for Straight Abutment

REID
Straight Abutment

COWELL® IMPLANT SYSTEM


Healing
Fixture Cover Screw Abutment

Straight Abutment
D
Diameter Ø3.5
7 5.5 L Length [Cuff] 8 [0.5] 8 [1] 8 [2] 8 [3] 8 [4]

COWELL® DIGITAL PRODUCTS


4
SR308 SR318 SR328 SR338 SR348
C
> Packing unit : 1 Straight Abutment.
> For Cement Retained Prosthesis.
> Integrated with screw and abutment.
> Tightened with the Shoulder Driver.
> Tightening torque force : 30 N.cm.
> Direct impression.

COWELL® EXPERT INSTRUMENTS


Shoulder Driver
Diameter
Height Ø4.5
H
19 KRR19L
D > Packing unit : 1 Driver.
> To install the Straight Abutment.

REGENERATIVE SOLUTION
COWELL®
074 INNO-SUB. NARROW IMPLANT
COWELLMEDI HISTORY
INNO INTERNAL IMPLANT (Int.)
System Flow

Fixture Abutment Impression

REID
Fixture Level
083p 083p 083p 084p 084p 084p
Procedure I

Impression
Prosthetic

Cemented Angulated Meta G UCLA Replica Pick-up Transfer Post


Impression Coping

COWELL® IMPLANT SYSTEM


086p 086p 086p 086p 087p 087p
Procedure II
Prosthetic

Solid Solid Solid Solid Positioning Solid Solid


Abutment Cap Impression Cap Cylinder Lab Analog Plastic Coping
Octa 3.1

Platform
Ø4.8 / 5.9

Cuff
089p 089p 089p 089p 089p

COWELL® DIGITAL PRODUCTS


1.8 / 2.4mm
Procedure III
Prosthetic

Length Shoulder
7 / 8 / 10 / 12 / 14mm Shoulder Shoulder Shoulder
Positioning

Abutment Level
Shoulder Abutment Cap Impression Cap Lab Analog
Cylinder

Impression
Diameter
Ø3.5 / 4.0 / 4.5 / 5.0 / 6.0
091p 092p 092p
Procedure IV
Prosthetic

COWELL® EXPERT INSTRUMENTS


Sonator
S Abutment Impression Coping Sonator Analog

095p 095p
Procedure V
Prosthetic

Ball Analog
Ball

REGENERATIVE SOLUTION
COWELL®
076 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 077
COWELLMEDI HISTORY
INNO Internal Impant (Int.) No-Mount Cuff 1.8mm fixture > Packing unit : 1 Fixture + 1 Cover Screw.

* Diameter
Ø3.5
Length
Internal Fixture * Platform : Ø4.8
INT. Surface Treatment : SLA-SH® 7 - C
OCTAGON Platform 8 10 12 14
> Interchangeable with 1 staged internal fixture.
SYSTEM 8 IPT3508SM
> Internal Octa Connection (Taper 8°/ Octa 3.1). L
> No-Mount type. 10 IPT3510SM Fixture
Diameter

12 IPT3512SM

REID
14 IPT3514SM D
Octa 3.1
* Diameter
Ø4.0
Length
Platform * Platform : Ø4.8
7 IPT4007SM
C 7 8 10 12 14
8 IPT4008SM

COWELL® IMPLANT SYSTEM


10 IPT4010SM L
C 12 IPT4012SM
14 IPT4014SM
D

* Diameter
Ø4.5
Length

L 7 IPT4507SM
* Platform : Ø4.8
C 7 8 10 12 14
8 IPT4508SM
L
10 IPT4510SM

COWELL® DIGITAL PRODUCTS


12 IPT4512SM
14 IPT4514SM D

* Diameter
Ø5.0
D Length

* Platform : Ø5.9
7 IPT5007SM C 7 8 10 12 14
8 IPT5008SM
INNO Fixture Code L
10 IPT5010SM
P

COWELL® EXPERT INSTRUMENTS


I T 40 10 S M Ex.)
SLA Cuff 1.8 No-Mount IPT4010SM
12 IPT5012SM
Type P=Cuff 1.8 body Diameter Length Surface Treatment Mount 14 IPT5014SM D
Internal Taper Ø4.0 10mm SLA No-Mount

* Diameter
Ø6.0
I T 40 10 S M Ex.)
SLA Cuff 2.4 No-Mount IT4010SM
Length
* Platform : Ø5.9
Type Cuff 2.4 body Diameter Length Surface Treatment Mount C 7 8 10 12
7 IPT6007SM
Internal Taper Ø4.0 10mm SLA No-Mount
8 IPT6008SM L
10 IPT6010SM
12 IPT6012SM
D
14 -

REGENERATIVE SOLUTION
COWELL®
078 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 079
COWELLMEDI HISTORY
No-Mount Cuff 2.4mm fixture > Packing unit : 1 Fixture + 1 Cover Screw. Cover Screw
D
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Diameter
Length Ø5.0 Ø6.0
L
* Diameter
Ø3.5 6.5 ICVR002 ICVW002
Length
* Platform : Ø4.8 > Packing unit : 1 Cover Screw.
> To seal the conical interface of fixture.
7 - C
Platform 8 10 12 14 > Tightened with the 1.2 Hex Driver.
8 IT3508SM > Tightening torque force : 5~10 N.cm.
L
10 IT3510SM Fixture
Diameter

12 IT3512SM

REID
14 IT3514SM D

* Diameter
Ø4.0
Length Headless Screw Diameter
Length Ø3.5
D
* Platform : Ø4.8 6 ICVR001
7 IT4007SM
C 7 8 10 12 14
8 IT4008SM L > Packing unit : 1 Headless Screw.
> For narrow mesio-distal distance.

COWELL® IMPLANT SYSTEM


10 IT4010SM L
> Tightened with the 1.2 Hex Driver.
12 IT4012SM > Tightening torque force : 5~10 N.cm.
14 IT4014SM
D

* Diameter
Ø4.5
Length

* Platform : Ø4.8
7 IT4507SM C 7 8 10 12 14
8 IT4508SM
Healing Abutment
L
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
10 IT4510SM Diameter
D Height Ø5.5 Ø6.6

COWELL® DIGITAL PRODUCTS


12 IT4512SM H 2 IHCR020 IHCW020
14 IT4514SM D
3 IHCR030 IHCW030
4.5 IHCR045 IHCW045
* Diameter
Ø5.0 > Packing unit : 1 Abutment.
Length > For remodeling gingival contour during soft tissue healing.
* Platform : Ø5.9 > Select according to gingival height and abutment type.
7 IT5007SM > Tightened with the 1.2 Hex Driver.
C 7 8 10 12 14 > Tightening torque force : 5~10 N.cm.
8 IT5008SM
L
10 IT5010SM
12 IT5012SM

COWELL® EXPERT INSTRUMENTS


14 IT5014SM D

* Diameter
Ø6.0
Length
* Platform : Ø5.9
C 7 8 10 12
7 IT6007SM
8 IT6008SM L
10 IT6010SM
12 IT6012SM
D
14 -

REGENERATIVE SOLUTION
COWELL®
080 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 081
COWELLMEDI HISTORY
Cemented Extension Abutment
Prosthetic Procedure I D
1.2 Hex.

2.5
Type
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5]
Octa
Ø5.9 [Ø5.0 / Ø6.0]
L6 Diameter
Component Selection Guide for Cemented & UCLA Abutment Cuff Ø4.8 Ø5.8 Ø5.9 Ø6.9
C 0.5 IECR406 IECW506
1 IECR416 IECW516
2 IECR426 IECW526
Octa N-Octa 3 IECR436 IECW536

Type N-Octa

REID
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Diameter
Coping Screw Cuff Ø4.8 Ø5.8 Ø5.9 Ø6.9
0.5 IENR406 IENW506
1 IENR416 IENW516
2 IENR426 IENW526
(15°) (25°) 3 IENR436 IENW536

> Packing unit : 1 Cemented Extension Abutment + 1 Abutment Screw.

COWELL® IMPLANT SYSTEM


> For Cement Retained or Screw-Cement Retained Prosthesis.
> Cutting surface for anti-rotation of prosthesis.
> Connected with the Abutment Screw (ISHR110).
(Octa) (N-Octa) (Octa) (Octa) (N-Octa) > Tightened with the 1.2 Hex Driver and Torque Wrench.
Cemented Extension Angulated Abutment Meta G UCLA Abutment > Tightening torque force : 35 N.cm.
Abutment > Fixture level impression.

Angulated Abutment
15° Type Octa
1.2 Hex. Platform [Fixture Dia.] Ø4.8 & Ø5.9 [Ø3.5 / Ø4.0 / Ø4.5 / Ø5.0 / Ø6.0]

COWELL® DIGITAL PRODUCTS


L Diameter(Angle)
2.5 Length 3.8 (15°) 3.8 (25°)
Replica
8 IAAR158A IAAR258A

D > Packing unit : 1 Abutment + 1 Abutment Screw.


> For Cement Retained or Screw-Cement Retained Prosthesis.
> Solution for anterior esthetic zone.
> Connected with the Abutment Screw (ISHR100).
Octa
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 35 N.cm.
> Fixture level impression.

(Octa) (N-Octa)

COWELL® EXPERT INSTRUMENTS


Pick-up Impression Coping Transfer Post & Screw

Meta G UCLA Abutment


Type Octa N-Octa
D
1.2 Hex. Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Diameter
Length Ø5 Ø6 Ø5 Ø6
2.5
L
12 IGOR400N IGOW500N IGNR400N IGNW500N

> Packing unit : 1 Meta G UCLA Abutment + 1 Abutment Screw.


Healing > For Screw-Cement or Screw Retained Prosthesis.
Fixture Cover Screw Headless Screw Abutment > Modification to angulated abutment, customized abutment and telescopic abutment.
> CCM alloy core for precise connection.

REGENERATIVE SOLUTION
Octa N-Octa
> Cast with non-precious metal or gold alloy.
> Connected with the Abutment Screw (ISHR120).
> Tightened with the 1.2 Hex Driver and Torque Wrench.

COWELL®
> Tightening torque force : 35 N.cm.
> Fixture level impression.

082 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 083


COWELLMEDI HISTORY
Abutment Screw Diameter Ø2.5 Ø2.5 Ø2.5

Prosthetic Procedure II
Height
1.2 Hex. 1.2 Hex. 1.2 Hex.
6.3 ISHR100
7.8 ISHR120
D D D
9.2 ISHR110 Component Selection Guide for Solid Abutment
H
> Packing unit : 1 Abutment Screw.
> ISHR110 : Cemented Abutment.
> ISHR100 : Angulated Abutment.
> ISHR120 : Meta G Abutment.
> Tightened with the 1.2 Hex Driver and Torque Wrench.

(Crown) (Bridge)

REID
Solid Plastic Coping

Replica
D Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Diameter
Height Ø4.8 Ø5.9
H 12 IROR001 IROW001
> Packing unit : 1 Replica.
> Mimicking of conical interface of fixture.

COWELL® IMPLANT SYSTEM


> Analog of fixture for working cast.
Solid Lab Analog

Pick-up Impression Coping


D
Type Octa Solid Impression Cap Solid Positioning Cylinder
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
L Diameter
Length Ø5.5 Ø6.6
2 Pieces

COWELL® DIGITAL PRODUCTS


14.9 IIOR001 IIOW001

> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (IIOR001S).


> For open tray impression.
> Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Octa > Tightening torque force: 12~15 N.cm. Solid Abutment Cap

Transfer Post

COWELL® EXPERT INSTRUMENTS


D

Type Octa N-Octa


Solid Abutment
L Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Diameter
Length Ø4.85 Ø5.95 Ø4.85 Ø5.95
11.6 ITOR400 ITOW500 ITNR400 ITNW500
2 Pieces 1 Piece
> Packing unit : Octa - 1 Transfer Post + 1 Guide Pin (Regular: ITOR400S / Wide: ITOW500S)
N-Octa - 1 Transfer Post (solid screw).
> For closed tray impression.
Octa N-Octa > Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.

REGENERATIVE SOLUTION
Healing
Fixture Cover Screw Headless Screw Abutment

COWELL®
084 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 085
COWELLMEDI HISTORY
Solid Abutment Solid Positioning Cylinder
D Platform [Fixture Dia.] Ø4.8 & Ø5.9 [Ø3.5 / Ø4.0 / Ø4.5 / Ø5.0 / Ø6.0]
D
Diameter Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5]
L Ø3.5
Diameter
Length 3 4 5.5 7 Height Ø5.7
H 10.2 IPCR001
IASR030 IASR040 IASR055 IASR070

> Packing unit : 1 Solid Abutment + 1 Abutment Cap. > Packing unit : 1 Positioning Cylinder.
> For Cement Retained Prosthesis. > Inner cutting surface for anti-rotation on abutment.
> Cutting surface for anti-rotation of prosthesis. > Insert into the Impression Cap.
> Integrated with screw and abutment.
> Tightened with the Shoulder Driver.
> Tightening torque force : 35 N.cm.

REID
> Abutment level impression :
Impression cap in platform Ø4.1 fixture and direct impression in platform Ø5.8 fixture.

4IPVMEFSⰝ KRR19L

COWELL® IMPLANT SYSTEM


Solid Abutment Cap Solid Lab Analog
Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] D
Platform [Fixture Dia.]
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5]
D Diameter L
Height Ø5.4
Length 3 4 5.5 7
Diameter
H
5.2 IASR130
4.8 ILSR030 ILSR040 ILSR055 ILSR070
6.2 IASR140
> Packing unit : 1 Lab Analog.
7.7 IASR155
> Replacement of abutment shape in working cast.
9.2 IASR170 > Choose by abutment length.

> Packing unit : 1 Solid Abutment Cap.


> Protection from cheek and tongue for gingival healing period.
> Alternative usage for sub-structure of temporary prosthesis.

COWELL® DIGITAL PRODUCTS


Solid Impression Cap Solid Plastic Coping

COWELL® EXPERT INSTRUMENTS


D
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Type Crown Bridge
Diameter
H Height 8 H Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5]
8 IICR001 Diameter
Height Ø5 Ø5
> Packing unit : 1 Impression Cap. D 10 IPCC001 IPCB001
> Connected with the Positioning Cylinder.
> Confirm locking with abutment by rotation of clockwise and anti-clockwise direction. > Packing unit : 1 Plastic Coping.
> Connect with the Lab Analog.
Crown Bridge > Burn out and casting for metal framework.

REGENERATIVE SOLUTION
COWELL®
086 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 087
COWELLMEDI HISTORY
Shoulder Abutment Type Crown Bridge
D

Prosthetic Procedure III


Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
2 Pieces Diameter
L Platform Length Ø3.5 Ø4.5 Ø3.5 Ø4.5
4 ISAC404 ISAC504 ISAB404 ISAB504
Component Selection Guide for Shoulder Abutment Fixture 5.5 ISAC405 ISAC505 ISAB405 ISAB505
Diameter
7 ISAC407 ISAC507 ISAB407 ISAB507

> Packing unit : 1 Shoulder Abutment + 1 Abutment Cap.


> For Cement Retained Prosthesis.
Crown Bridge
> Dual anti-rotation grip with single crown for prevention of screw loosening.
> Integrated with the Screw and Abutment.
> Tightened with the Shoulder Driver.

REID
> Tightening torque force : 35 N.cm.
> Abutment level impression.
(Crown) (Bridge)
4IPVMEFSⰝ KRR19L 4IPVMEFSⰝ KRW19L
Shoulder Lab Analog

Shoulder Abutment Cap Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]

COWELL® IMPLANT SYSTEM


Platform [Fixture Dia.]
D Diameter
Height Ø5.4 Ø5.4
6.2 IASR140 IASW140
H
Shoulder Impression Cap Shoulder Positioning Cylinder 7.7 IASR155 IASW155
9.2 IASR170 IASW170
> Packing unit : 1 Shoulder Abutment Cap.
> Protection from cheek and tongue for gingival healing period.
> Alternative usage for sub-structure of temporary prosthesis.

Shoulder Abutment Cap


Shoulder Impression Cap
Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]

COWELL® DIGITAL PRODUCTS


D Platform [Fixture Dia.]
Diameter
Height 8 9
H 8 IICR001 IICW001

> Packing unit : 1 Impression Cap.


> Connected with the Positioning Cylinder.
> Confirm locking with abutment by rotation of clockwise and anti-clockwise direction.

Shoulder Positioning Cylinder Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
(Crown) (Bridge) D
Diameter
Shoulder Abutment 5.7 6.8

COWELL® EXPERT INSTRUMENTS


Height
10.7 SAPR001 SAPW001
H
> Packing unit : 1 Positioning Cylinder.
> Inner cutting surface for anti-rotation on abutment.
> Insert into the Impression Cap.

Shoulder Lab Analog


D Type Crown Bridge
Platform [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
L
Healing Diameter
Fixture Cover Screw Headless Screw Abutment Length Ø4.8 Ø5.9 Ø4.8 Ø5.9
4 SLCR040 SLCW040 SLBR040 SLBW040

REGENERATIVE SOLUTION
5.5 SLCR055 SLCW055 SLBR055 SLBW055
7 SLCR070 SLCW070 SLBR070 SLBW070

COWELL®
> Packing unit : 1 Lab Analog.
> Replacement of abutment shape in working cast.
Crown Bridge > Choose according to width and length of abutment.

088 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 089


COWELLMEDI HISTORY
Prosthetic Procedure IV Sonator S Abutment
Black
Block-out Processing
Component Selection Guide for Sonator Abutment Outer Cap Spacer Male H-Type Inner Caps

2.25mm

Ø5.4
Black Bule : 10N Pink : 15N White : 22N
Block-out Processing
Outer Cap Spacer Male
Carrier
Diameter Ø4.0

REID
Cuff 0.6 2 3 4
Length
1.5 IONS401 IONS402 IONS403 IONS404
> Packing unit : 1 Sonator S Abutment + Carrier + 3 H-Type Inner Caps + Outer Cap + Block-out Spacer
+ Black Processing Male.
> For Implant Supported Over-denture Prosthesis.
> Stable with low vertical height.
> 6 kinds of the Inner Caps give various holding force (Both, H and NH-Type Inner Caps are used for Sonator S Abutment).
H-Type Inner Caps NH-Type Inner Caps > Path compensation up to 20° based on 2 implants.
Ratchet Driver
D > Carrier : Used for delivery of the abutment.

COWELL® IMPLANT SYSTEM


L > Tightened with the Ratchet Driver and Torque wrench.
C
> Tightening torque force : 30 N.cm.
> Abutment level impression.

Sonator Lab Analog

COWELL® DIGITAL PRODUCTS


Outer Cap
Diameter
D
Black Processing Male Height Ø5.4
2.25 SONOC01
H
> Packing unit : 2 Outer Caps and 2 Black Processing Males.
> Black Processing Male : Inserted and Removed with the I&R Driver.

Sonator Impression Coping

COWELL® EXPERT INSTRUMENTS


H-Type Inner Cap Code SONIC01
> Packing unit : 3 Block-out Spacers + 3 Inner Caps (1 Blue, 1 Pink and 1 White).
> Path compensation up to 20° based on 2 implants.
Sonator S Abutment Block-out
Spacer Inner Cap > Mainly used for the Sonator S Abutment.
> Inner Caps : Inserted and Removed with the I&R Driver.

Bule : Pink : White :


Retention Force Retention Force Retention Force
About 10N About 15N About 22N

REGENERATIVE SOLUTION
Healing
Fixture Cover Screw Headless Screw Abutment

COWELL®
090 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 091
COWELLMEDI HISTORY
NH-Type Inner Cap Code SONIC02 Sonator S Ratchet Driver
H Type
> Packing unit : 3 Block-out Spacers + 3 Inner Caps (1 Red, 1 Orange and 1 Green). Height Ratchet
Block-out > Path compensation up to 40° based on 2 implants. 18 SONRD19L
Spacer Inner Cap > Mainly used for the Sonator A Abutment.
> Inner Caps : Inserted and Removed with the I&R Driver. > Used to tighten and untighten the Sonator S Abutment.

Red : Orange : Green :


Retention Force Retention Force Retention Force
About 10N About 15N About 22N

REID
COWELL® IMPLANT SYSTEM
Sonator Impression Coping I & R Driver
Diameter Height 95.4
Length Ø4.8
D
Black Processing Male SONIR002
3 SONIP04
H
L
> Packing unit : 4 Impression Copings and 4 Black Processing Males.
> Abutment level pick-up impression.
> Connected over the Sonator Abutment after placing the Block-out Spacer. For Removal For Insertion
> For close tray impression.
> Used to insert and remove the Inner Caps and Block Processing Male.

COWELL® DIGITAL PRODUCTS


Sonator Lab Analog

COWELL® EXPERT INSTRUMENTS


Diameter
D Length Ø4
8.8 SONLA04

> Packing unit : 4 Lab Analogs.


L
> Replacement of abutment shape in working cast.

REGENERATIVE SOLUTION
COWELL®
092 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 093
COWELLMEDI HISTORY
Ball Abutment
Outer Cap Block-out Spacer

Prosthetic Procedure V Ø3.4


2.4mm Length
4
Diameter Ø3.5
IBAT404R
Component Selection Guide for Ball Abutment
> Packing unit : 1 Ball Abutment + 3 Inner Caps (1 per each color) + 1 Block-out Spacer + 1 Outer Cap.
> For Implant Supported Over-denture Prosthesis.
Red : 10N Orange : 15N Green : 20N
> Tightened with the Ball Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
Ball Inner Cap > Direct impression.
D

REID
L

Ball Outer Cap Block-out Spacer

Ball Abutment

Ball Outer Cap Diameter


Ø3.4

COWELL® IMPLANT SYSTEM


D Length
Red : 10N Orange : 15N Green : 20N 2.4 BATC003C
Ball Inner Cap L
> Packing unit : 2 Outer Caps.

Ball Inner Cap


Block-out Ball Inner Cap
Spacer
BATC003I
> Packing unit : 2 Block-out Spacers + 6 Inner Caps (2 per each color).
Red : 10N Orange : 15N Green : 20N
> Retention force : Red 10N, Orange 15N & Green 20N.
Ball Analog

COWELL® DIGITAL PRODUCTS


Ball Analog
D
Diameter
Length Ø4.0
L
4 SBAL400

> Packing unit : 4 Lab Analogs.


> Replacement of abutment shape in working cast.

Ball Abutment

COWELL® EXPERT INSTRUMENTS


Type
Ball Driver Height Ratchet
H 19 KRB19L
> Packing unit : 1 Ball Driver. *Extra Product
> Used with the Torque Wrench to tighten and untighten the Ball Abutment.

Healing
Fixture Cover Screw Headless Screw Abutment

I&R Driver Height 100


KBIR01

REGENERATIVE SOLUTION
H

For Removal For Insertion

COWELL®
> Packing unit : 1 I&R Driver.
> Used to insert and remove the Inner Caps into and out of the Outer Cap.

094 INNO-INTERNAL IMPLANT INNO-INTERNAL IMPLANT 095


COWELLMEDI HISTORY
INNO EXTERNAL IMPLANT (Ext.)
System Flow

Fixture Abutment Impression

REID
102p 102p

104p 104p 104p


Cemented Angulated
Procedure I

Fixture Level
Prosthetic

Impression

COWELL® IMPLANT SYSTEM


102p 103p 103p Replica Pick-up Squared Transfer Post
Impression Coping

Temporary Meta G UCLA Plastic Sleeve

Hex : 2.7 / 3.4

Platform
Ø4.1 / 5.1

COWELL® DIGITAL PRODUCTS


106p 106p 107p 107p 107p
Length
Procedure II
Prosthetic

7 / 8 / 10 / 12 / 14mm

Shoulder Shoulder Shoulder Positioning Shoulder


Shoulder Abutment Cap Impression Cap Cylinder Lab Analog
Diameter
Ø3.5 / 4.0 / 4.5 / 5.0 / 6.0

Abutment Level
Impression

COWELL® EXPERT INSTRUMENTS


109p 109p
Procedure III
Prosthetic

Ball Ball Analog

REGENERATIVE SOLUTION
COWELL®
096 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 097
COWELLMEDI HISTORY
INNO External Implant (Ext.)
Pre-Mount > Packing unit :1 Fixture + 1 Mount + 1 Mount Screw.

* Diameter
Ø3.5 * Hex 2.7
Length * Platform : Ø4.1

External Fixture
EXT.
Surface Treatment : SLA-SH® 7 -
HEXAGON
SYSTEM > Interchangeable with external hexagonal fixture. 8 ET3508S
>External hex connection (Hex 2.7 / 3.4). 10 ET3510S
12 ET3512S

REID
14 ET3514S

Hex 2.7 / 3.4


* Diameter
Ø4.0 * Hex 2.7
Length * Platform : Ø4.1

Platform 7
8
ET4007S
ET4008S

COWELL® IMPLANT SYSTEM


10 ET4010S
12 ET4012S
14 ET4014S

* Diameter
Ø4.5 * Hex 2.7
Length * Platform : Ø4.1

L 7 ET4507S
8 ET4508S
10 ET4510S

COWELL® DIGITAL PRODUCTS


12 ET4512S
14 ET4514S

* Diameter
Ø5.0 * Hex 3.4
Length * Platform : Ø5.1
D
7 ET5007S
8 ET5008S
INNO Fixture Code 10 ET5010S

COWELL® EXPERT INSTRUMENTS


12 ET5012S
E T 40 10 S Ex.) 14 ET5014S
Type body Diameter Length Surface Treatment Mount SLA Pre-Mount ET4010S
External Taper Ø4.0 10mm SLA Pre-Mount
* Hex 3.4
* Diameter * Platform : Ø5.1
Ø6.0
Length

7 ET6007S
8 ET6008S
10 ET6010S
12 ET6012S
14 -

REGENERATIVE SOLUTION
COWELL®
098 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 099
COWELLMEDI HISTORY
Fixture Mount
D

Hex Hex2.7 Hex3.4 Prosthetic Procedure I


L Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Diameter
Component Selection Guide for Cemented & UCLA Abutment
Length Ø4.9 Ø5.5
7.2 MER001 MEW002

> Packing unit : 1 Mount + 1 Mount Screw.


> Tightened with the 1.2 Hex Driver.
> Tightening torque force : 5~10 N.cm.

REID
Abutment Screw

(15°) (25°)

COWELL® IMPLANT SYSTEM


Cover Screw (Hex)
(H
(Hex
(He
Hex
ex)

(Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)

D Hex Hex2.7 Hex3.4 Cemented Angulated Abutment Temporary Abutment Meta G UCLA Abutment Plastic Sleeve
1.1mm Abutment
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
L
Diameter
Length Ø4.3 Ø5.4
5.8 VNR001 VNW001

> Packing unit : 1 Cover Screw.


> To seal the conical interface of fixture.
> Tightened with the 1.2 Hex Driver.
> Tightening torque force : 5~10 N.cm.

COWELL® DIGITAL PRODUCTS


Replica

Healing Abutment Hex Hex2.7 Hex3.4

COWELL® EXPERT INSTRUMENTS


(Hex) (N-Hex) (Hex) (N-Hex)
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Pick-up Squared
D Diameter Impression Coping Transfer Post
Length Ø5.0 Ø6.0
L
2.8 HNR502 HNW602
3.8 HNR503 HNW603
4.8 HNR504 HNW604
5.8 HNR505 HNW605
6.8 HNR506 HNW606
7.8 HNR507 HNW607

> Packing unit : 1 Abutment.


> For remodeling gingival contour during soft tissue healing. Healing
> Select according to gingival height and abutment type. Fixture Cover Screw Abutment

REGENERATIVE SOLUTION
> Tightened with the 1.2 Hex Driver.
> Tightening torque force : 5~10 N.cm.

COWELL®
100 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 101
COWELLMEDI HISTORY
Cemented Abutment Meta G UCLA Abutment
Type Hex
Hex Hex2.7 Hex3.4 1.2 Hex.
1.2 Hex. Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex
D D
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
L
Diameter Ø5.0 Ø6.0 Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
L L
Length Length
Cuff 6 8 6 8 13 13 13 13
Cuff
C
C C 1 CHR516 CHR518 CHW616 CHW618 1.2 GHR001N GHW001N GNR001N GNW001N
D
2 CHR526 CHR528 CHW626 CHW628 > Packing unit : 1 Abutment + 1 Abutment Screw.
3 CHR536 CHR538 CHW636 CHW638 > For Screw-Cement or Screw Retained Prosthesis.
Hex N-Hex Hex N-Hex > Modification to angulated abutment, customized abutment and telescopic abutment.
4 CHR546 CHR548 CHW646 CHW648
> CCM alloy core for precise connection.

REID
> Cast with non-precious metal or gold alloy.
Type N-Hex > Connected with the Abutment Screw.
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] > Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex > Tightening torque force : 35 N.cm.
Diameter Ø5.0 Ø6.0
Platform > Fixture level impression.
Length
Cuff 6 8 6 8
1 CNR516 CNR518 CNW616 CNW618
2 CNR526 CNR528 CNW626 CNW628
3 CNR536 CNR538 CNW636 CNW638

COWELL® IMPLANT SYSTEM


4 CNR546 CNR548 CNW646 CNW648

> Packing unit : 1 Abutment + 1 Abutment Screw. > Tightened with the 1.2 Hex Driver and Torque Wrench.
> For Cement Retained and Screw-Cement Retained Prosthesis. > Tightening torque force : 35 N.cm
> Cutting surface for anti-rotation of prosthesis. > Fixture level impression.
> Connected with the Abutment Screw.

Angulated Abutment Plastic Sleeve


Type[Hex] Hex2.7 Hex3.4 Hex2.7 Hex3.4 Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] 1.2 Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
15° 25° 1.2 Hex.
Diameter (Angle) Ø5 (15°) Ø6 (15°) Ø5 (25°) Ø6 (25°) Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5

COWELL® DIGITAL PRODUCTS


Length L Length
Cuff 8 8 8 8 Cuff 11.8 11.8 11.8 11.8
L 2 AAR152 AAW152 AAR252 AAW252 1.2 PHR001 PHW001 PNR001 PNW001
3 AAR153 AAW153 AAR253 AAW253 C > Packing unit : 1 Abutment + 1 Abutment Screw.
C > Same purpose of use as Meta G UCLA Abutment but low accuracy of connection.
D
4 AAR154 AAW154 AAR254 AAW254
D > PMMA material.
> Connected with the Abutment Screw.
> Packing unit : 1 Abutment + 1 Abutment Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> For Screw-Cement or Cement Retained Prosthesis. Hex N-Hex
Hex
> Tightening torque force : Finger light force during wax Pattern fabrication, 35 N.cm after casting.
> Solution for anterior esthetic zone.
> Conneced with the Abutment Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 35 N.cm.
> Fixture level impression.

COWELL® EXPERT INSTRUMENTS


Temporary Abutment
1.2 Hex.
Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex Abutment Screw
Hex Hex2.7 Hex3.4
L Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] 1.2 Hex. 1.2 Hex.
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Diameter Ø5.4 Ø5.95 Ø5.4 Ø5.95 Diameter
Length D D Height Ø2.5 Ø3.0
Cuff 12 12 12 12
C 8 SHR100 SHW100
D
1.5 THR001 THW001 TNR001 TNW001 H
> Packing unit : 1 Abutment Screw.
> Packing unit : 1 Abutment + 1 Abutment Screw. > Tightened with the 1.2 Hex Driver and Torque Wrench.
> For Screw-Cement Retained Prosthesis.
Hex N-Hex > For provisional restoration.
> Connected with the Abutment Screw.

REGENERATIVE SOLUTION
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 20 N.cm.

COWELL®
102 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 103
COWELLMEDI HISTORY
Replica
D Type[Hex]
Platform [Fixture Dia.]
Hex[2.7]
Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5]
Hex[3.4]
Ø5.1 [Ø5.0 / Ø6.0] Prosthetic Procedure II
Diameter
H Height Ø4.1 Ø5.1 Component Selection Guide for Shoulder Abutment
12 LHR001 LHW001
> Packing unit : 1 Replica.
> Mimicking of conical interface of fixture.
> Analog of fixture for working cast.

REID
(Crown) (Bridge)

Shoulder Lab Analog

Pick-up Squared Impression Coping

COWELL® IMPLANT SYSTEM


D
Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
L Diameter
Length Ø5 Ø5.8 Ø5 Ø5.8
Shoulder Impression Cap Shoulder Positioning Cylinder
17 IHR500 IHW600 INR500 INW600
2 Pieces
> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (Regular : UHR115 / Wide : UHW115).
> For Open Tray Impression.
> Tightened with the 1.2 Hex Driver and Torque Wrench.

Hex N-Hex

COWELL® DIGITAL PRODUCTS


Shoulder Abutment Cap

Transfer Post (Crown) (Bridge)

COWELL® EXPERT INSTRUMENTS


D
Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex Shoulder Abutment
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
L
Diameter
Length Ø4.8 Ø5.8 Ø4.8 Ø5.8
2 Pieces
13.1 IHR510 IHW610 INR510 INW610
> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (Regular : IHR510S, IHR610S / Wide : IHW610S).
> For Closed Tray Impression.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex N-Hex

Healing
Fixture Cover Screw Abutment

REGENERATIVE SOLUTION
COWELL®
104 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 105
COWELLMEDI HISTORY
Shoulder Abutment Shoulder Impression Cap
D Type Crown Hex Hex2.7 Hex3.4
Diameter 8 9
Hex Hex2.7 Hex3.4 Height
2 Pieces L H
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] 8 IICR001 IICW001

C Diameter Ø4.8 Ø5.9 > Packing unit : 1 Impression Cap.


D
Length > Connected with the Positioning Cylinder.
Cuff 4 5.5 7 4 5.5 7
> Confirm locking with abutment by rotation of clockwise and anti-clockwise direction.
1 SAC414 SAC415 SAC417 SAC514 SAC515 SAC517
2 SAC424 SAC425 SAC427 SAC524 SAC525 SAC527

Crown
3 SAC434 SAC435 SAC437 SAC534 SAC535 SAC537
Hex

REID
4 SAC444 SAC445 SAC447 SAC544 SAC545 SAC547
Platform

Type Bridge
Hex Hex2.7 Hex3.4
D
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
L Diameter Ø4.8 Ø5.9
2 Pieces
Length
C Cuff 4 5.5 7 4 5.5 7

COWELL® IMPLANT SYSTEM


1 SAB414 SAB415 SAB417 SAB514 SAB515 SAB517
2 SAB424 SAB425 SAB427 SAB524 SAB525 SAB527
3 SAB434 SAB435 SAB437 SAB534 SAB535 SAB537
Shoulder Positioning Cylinder Hex Hex2.7 Hex3.4
4 SAB444 SAB445 SAB447 SAB544 SAB545 SAB547 Diameter Ø4.4 Ø5.5
Length
Bridge
> Packing unit : 1 Abutment. 10.7 SAPR001 SAPW001
L
> For Cement Retained Prosthesis. > Packing unit : 1 Cyilnder.
> Dual anti-rotation grip for prevention of screw loosening. > Inner cutting surface for anti-rotation on abutment.
> Integrated with screw and abutment. D > Insert into the Impression Cap.
> Tightened with the Shoulder Driver.
> Tightening torque force : 35 N.cm.
> Abutment level impression : Impression cap in platform Ø4.1 fixture and direct impression in platform Ø5.8 fixture.

COWELL® DIGITAL PRODUCTS


4IPVMEFSⰝ KRR19L 4IPVMEFSⰝ KRW19L

Shoulder Lab Analog


Shoulder Abutment Cap D

COWELL® EXPERT INSTRUMENTS


Hex Hex2.7 Hex3.4 Type Crown Bridge
L
Diameter Ø5.4 Ø6.5 Diameter
D Height Length Ø4.8 Ø5.9 Ø4.8 Ø5.9
6.2 IASR140 IASW140 4 SLCR040 SLCW040 SLBR040 SLBW040
H
7.7 IASR155 IASW155 5.5 SLCR055 SLCW055 SLBR055 SLBW055
9.2 IASR170 IASW170 7 SLCR070 SLCW070 SLBR070 SLBW070
> Packing unit : 1 Shoulder Abutment Cap. > Packing unit : 1 Analog.
> Protection from cheek and tongue for gingival healing period. > Replacement of abutment shape in working cast.
> Alternative usage for sub-structure of temporary prosthesis. Crown Bridge > Choose by abutment length.

REGENERATIVE SOLUTION
COWELL®
106 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 107
COWELLMEDI HISTORY
Ball Abutment
Outer Cap Block-out Spacer

Prosthetic Procedure III Ø3.4


2.4mm Diameter

Cuff
Length
Ø5.0
4
Ø6.0
4
Component Selection Guide for Ball Abutment 1 EBAT411R EBAT511R
2 EBAT412R EBAT512R
Red : 10N Orange : 15N Green : 20N 3 EBAT413R EBAT513R
Ball Inner Cap 4 EBAT414R EBAT514R
D > Packing unit : 1 Ball Abutment + 3 Inner Caps (1 per each color) + 1 Block-out Spacer + 1 Outer Cap.
> For Implant Supported Over-denture Prosthesis.

REID
L > Tightened with the Ball Driver and Torque Wrench.
C
> Tightening torque force : 30 N.cm.
> Direct impression.
Ball Outer Cap Block-out Spacer

Ball Abutment

Ball Outer Cap

COWELL® IMPLANT SYSTEM


Diameter
D Length Ø3.4
Red : 10N Orange : 15N Green : 20N
2.4 BATC003C
Ball Inner Cap L
> Packing unit : 2 Outer Caps.

Ball Inner Cap


Block-out Ball Inner Cap
Spacer BATC003I
> Packing unit : 2 Block-out Spacers + 6 Inner Caps (2 per each color).
> Retention force : Red 10N, Orange 15N & Green 20N.
Red : 10N Orange : 15N Green : 20N

Ball Analog

COWELL® DIGITAL PRODUCTS


Ball Analog
D
Diameter
Length Ø4.0
L
4 SBAL400

> Packing unit : 4 Lab Analogs.


> Replacement of abutment shape in working cast.

Ball Abutment

COWELL® EXPERT INSTRUMENTS


Ball Driver
H
Type
Height Ratchet
19 KRB19L
> Packing unit : 1 Ball Driver. *Extra Product
> Used with the Torque Wrench to tighten and untighten the Ball Abutment.

Healing
Fixture Cover Screw Abutment I&R Driver Height 100
KBIR01

REGENERATIVE SOLUTION
For Removal For Insertion

COWELL®
> Packing unit : 1 I&R Driver.
> Used to insert and remove the Inner Caps into and out of the Outer Cap.

108 INNO-EXTERNAL IMPLANT INNO-EXTERNAL IMPLANT 109


COWELLMEDI HISTORY
INNO SUB. FULL SURGICAL KIT [KCA010F] INNO INT. FULL SURGICAL KIT [KCA010FI]
SUB. INT. > For the selection and use guide of the components for the Sub. Int. & Ext. Full Surgical Kit, refer to pages113 to 119.
> For INNO Submerged Implant System (Sub.). OCTAGON
HEXAGON > All components are for Sub. / Int. / Ext. except for the Fixture Drivers and the Depth Gauge used for Sub. exclusively.
> For the INNO Internal Implant System (Int.).
SYSTEM SYSTEM > All components are for Sub. / Int. / Ext. except for the Fixture Drivers used for Int. exclusively.

REID
COWELL® IMPLANT SYSTEM
Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF
'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM

COWELL® DIGITAL PRODUCTS


Path Drill Point Drill Ø2.2 X 7 Ø3.5 X 7 Ø4.0 X 7 Ø4.5 X 7 Ø5.0 X 7 Ø6.0 X 7 Path Drill Point Drill Ø2.2 X 7 Ø3.5 X 7 Ø4.0 X 7 Ø4.5 X 7 Ø5.0 X 7 Ø6.0 X 7
2KTD18 KPD01S KPSD2207 2KTD3707 2KTD4007 2KTD4507 2KTD5007 2KTD6007 2KTD18 KPD01S KPSD2207 2KTD3707 2KTD4007 2KTD4507 2KTD5007 2KTD6007

Parallel Pin Parallel Pin Ø2.2 X 8 Ø3.5 X 8 Ø4.0 X 8 Ø4.5 X 8 Ø5.0 X 8 Ø6.0 X 8 Parallel Pin Parallel Pin Ø2.2 X 8 Ø3.5 X 8 Ø4.0 X 8 Ø4.5 X 8 Ø5.0 X 8 Ø6.0 X 8
KPP002 KPP002 KPSD2208 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008 KPP002 KPP002 KPSD2208 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008

1.2 Hex Driver L 1.2 Hex Driver XL Ø2.2 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Ø6.0 X 10 1.2 Hex Driver L 1.2 Hex Driver XL Ø2.2 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Ø6.0 X 10
KHD1221 KHD1227 KPSD2210 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010 KHD1221 KHD1227 KPSD2210 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010

COWELL® EXPERT INSTRUMENTS


M. Mount Driver. L R. Mount Driver. L Ø2.2 X 12 Ø3.5 X 12 Ø4.0 X 12 Ø4.5 X 12 Ø5.0 X 12 Ø6.0 X 12 M. Mount Driver. L R. Mount Driver. L Ø2.2 X 12 Ø3.5 X 12 Ø4.0 X 12 Ø4.5 X 12 Ø5.0 X 12 Ø6.0 X 12
KMMD06L KRMD19L KPSD2212 2KTD3712 2KTD4012 2KTD4512 2KTD5012 2KTD6012 KMMD06L KRMD19L KPSD2212 2KTD3712 2KTD4012 2KTD4512 2KTD5012 2KTD6012
4VC'JYUVSF%SJWFS *OU'JYUVSF%SJWFS

M. Fixture Driver. S R. Fixture Driver. L Ø2.2 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14 M. Fixture Driver. S R. Fixture Driver. S Ø2.2 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14
2KMMS01S 2KHDS01L KPSD2214 2KTD3714 2KTD4014 2KTD4514 2KTD5014 KMMI01S KHDI01S KPSD2214 2KTD3714 2KTD4014 2KTD4514 2KTD5014

M. Fixture Driver. L R. Fixture Driver. XL Drill Extension Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø6.0 Countersink M. Fixture Driver. L R. Fixture Driver. L Drill Extension Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø6.0 Countersink
2KMMS01L 2KHDS01X KDE002 4KCS35 4KCS40 4KCS45 4KCS50 4KCS60 KMMI01L KHDI01L KDE002 4KCS35 4KCS40 4KCS45 4KCS50 4KCS60

REGENERATIVE SOLUTION
COWELL®
Torque Wrench Depth Gauge Torque Wrench Depth Gauge
A common tool for A common tool for
KTW001 KDG004 Sub. / Int. / Ext. An exclusive tool by type KTW001 KDG001 Sub. / Int. / Ext. An exclusive tool by type

110 SURGICAL KIT SURGICAL KIT 111


COWELLMEDI HISTORY
INNO EXT. FULL SURGICAL KIT [KCA010FE]

01
EXT. > For the selection and use guide of the components for the Sub. Int. & Ext. Full Surgical Kit, refer to pages 113 to 119. SUB. INT. EXT.
HEXAGON OCTAGON HEXAGON
HEXAGON > For the INNO External Implant System (Ext.). SYSTEM SYSTEM SYSTEM
SYSTEM > All components are for Sub. / Int. / Ext. except for the Fixture Drivers and the Multi Countersink used for Ext. exclusively.
Drill / Surgical Tool

REID
Point Drill
> Primarily used for marking the implant recipient site and to determine spacing.
> The point drill has a unique pointed tip, making this an excellent drill for starting the osteotomy
L
7 through the hard cortical plate.

31.8 3.5
Length 15
KPD01S

COWELL® IMPLANT SYSTEM


Path Drill
L > Used for the case that path modification is required.
> Excellent ablation force that does not slip in slanted bone.
35.2 14
> Easy to drill even in extraction socket without slipping.
12
10
8
7 Length 15
Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF Ⱍ'JYUVSF 3
'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 'JOBM%SJMM 2KTD18
Ø2

COWELL® DIGITAL PRODUCTS


Path Drill Point Drill Ø2.2 X 7 Ø3.5 X 7 Ø4.0 X 7 Ø4.5 X 7 Ø5.0 X 7 Ø6.0 X 7
2KTD18 KPD01S KPSD2207 2KTD3707 2KTD4007 2KTD4507 2KTD5007 2KTD6007
Length band 7mm Fixture
Ø2.2 Initial Drill > Initial stepped Drill - Ø2.2 / Ø2.8 / Ø3.3 mm 8mm Fixture
10mm Fixture
stepped osteotomy at Ø1.8 Drill site. 12mm Fixture
Ø2.2 X 8 18.5 4 L
Parallel Pin Parallel Pin Ø3.5 X 8 Ø4.0 X 8 Ø4.5 X 8 Ø5.0 X 8 Ø6.0 X 8 14mm Fixture
KPP002 KPP002 KPSD2208 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008 16&18mm Fixture

Length 8 9 11 13 15 17&19
1.2 Hex Driver L 1.2 Hex Driver XL Ø2.2 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Ø6.0 X 10 KPSD2207 KPSD2208 KPSD2210 KPSD2212 KPSD2214 KPSD2218
KHD1221 KHD1227 KPSD2210 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010 *Extra product

COWELL® EXPERT INSTRUMENTS


18.5 4 2 17

M. Mount Driver. L R. Mount Driver. L Ø2.2 X 12 Ø3.5 X 12 Ø4.0 X 12 Ø4.5 X 12 Ø5.0 X 12 Ø6.0 X 12
KMMD06L KRMD19L KPSD2212 2KTD3712 2KTD4012 2KTD4512 2KTD5012 2KTD6012
&YU'JYUVSF%SJWFS
%SJMM Stopper with irrigation groove.
%SJMM
M. Fixture Driver. S R. Fixture Driver. L Ø2.2 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14
4.9
KMME01S KHDE01L KPSD2214 2KTD3714 2KTD4014 2KTD4514 2KTD5014 Ø4.9 Crestal cutter – Flattening the slopped and sharp crestal ridge which
2.5 make crestal bone surround around the whole fixture platform.
3.3

1.5 2.8
Ø3.3/2.8 Pilot cutter – Stepped hole guiding the pathway of Ø3.5 / Ø4.0 /Ø4.5
fixture's final drill.
M. Fixture Driver. S R. Fixture Driver. L Drill Extension Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø6.0 Countersink
KMME02S KHDE02L KDE002 4KCS35 4KCS40 4KCS45 4KCS50 4KCS60

REGENERATIVE SOLUTION
Ø2.2 Path cutter – Determining the orientation of fixture installation.

The Initial Drill guides the pathway of

COWELL®
Torque Wrench Depth Gauge
Multi Countersink the Final Drills. The Final Drill is inserted a
A common tool for half into the Initial Drill's hole without drilling.
4KCS01 KTW001 KDG001 Sub. / Int. / Ext. An exclusive tool by type

112 SURGICAL KIT SURGICAL KIT 113


COWELLMEDI HISTORY
Final Drill > Ø3.5 / 4.0 / 4.5 / 5.0 / 6.0 fixture’s Final Drill.
Tap Drill
> Used in preparation of osteotomy in dense bone only.
18.5 4 L > 7 / 8 / 10 / 12 / 14 / 16 / 18mm fixture’s Final Drill.
Ø3.5
Fixture Dia. Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø6.0
Ø4.0
Fixture Dia.
Length Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø6.0 3KMTD35A 3KMTD40A 3KMTD45A 3KMTD50A 3KMTD60A
Ø4.5
8 2KTD3707 2KTD4007 2KTD4507 2KTD5007 2KTD6007 *Extra product
Ø5.0
9 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008
11 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010 Ø6.0

13 2KTD3712 2KTD4012 2KTD4512 2KTD5012 2KTD6012

REID
15 2KTD3714 2KTD4014 2KTD4514 2KTD5014
18.5 4 2 17
17&19 2KTD3718 2KTD4018 2KTD4518
*Extra product

COWELL® IMPLANT SYSTEM


Parallel Pin > Insert the Parallel Pin after Ⱍ2.2 or 3.5 Drill to check the osteotomy path.
Countersink > Bone quality 1 : high compressive placement of fixtures induces the failure of osseointegration > In order to prevent losing Parallel Pin in patient’s mouth, be sure to tie floss through the hole
and bone loss. in the Parallel Pin.
> Countersink decreases torque force (Ø4.0 Fixture : 80 N.cm -> 45 N.cm / Ø5.0 Fixture : 150 N.cm -> 45 N.cm). L

D
> Preventing compressive necrosis of dense cortical bone. Length 21 After Ø2.2 After Ø3.5
initial drilling. final drilling.
28.6 KPP002
Fixture Dia. Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø6.0
Diameter Ø3.7 Ø4.2 Ø4.6 Ø5.1 Ø6.0
4KCS35 4KCS40 4KCS45 4KCS50 4KCS60
1mm
1mm

COWELL® DIGITAL PRODUCTS


Lower margin of depth Upper margin of depth
marking line indicating marking line indicating
fixture platform level. 1 mm over fixture platform level.

COWELL® EXPERT INSTRUMENTS


Drill Extension > Used for lengthening the Drill when using a Hand-piece.
Multi Countersink > Do not go over recommended torque when using the Drill Extension.
L
Diameter Ø6.5
D Ø6.0 Fixture line. Length 27.5
4KCS01 Ø5.0 Fixture line.
34 Ø4.5 Fixture line. KDE002
> Only for Ext. Ø3.5 / Ø4.0 Fixture line.

Triangle mark indicating the cutting surface of the drill shaft.

REGENERATIVE SOLUTION
COWELL®
114 SURGICAL KIT SURGICAL KIT 115
COWELLMEDI HISTORY
Mount Driver > Used to install Pre-Mount type fixtures. Fixture Driver > Used to install No-Mount type fixtures.

Type Machine
Type Sub.
L Length Machine System
Length Sub. Int. Ext.(Hex 2.7) Ext.(Hex 3.4)
20.5(Short) KMMD06S
Int.
28.1 / 26.3 / 26.4 (Short) 2KMMS01S KMMI01S KMME01S KMME02S
26.3(Long) KMMD06L
33.3 / 30.5 / 31.4 (Long) 2KMMS01L KMMI01L KMME01L
32.3(X-Long) KMMD12X
Ext. 40.3 / 35.5 / 36.4 (X-Long) 2KMMS01X KMMI01X KMME01X
*Extra product
*Extra product

Type Ratchet
Sub. System
Length Sub. Int. Ext.(Hex 2.7) Ext.(Hex 3.4)

REID
L Type
Length Ratchet 20.7 / 19.5 / 19.9 (Short) 2KHDS01S KHDI01S KHDE01S
Int.
12(Short) KRMD12S 25.7 / 24.5 / 24.9 (Long) 2KHDS01L KHDI01L KHDE01L KHDE02L
19(Long) KRMD19L Ext. 30.7 / 29.5 / 29.9 (X-Long) 2KHDS01X KHDI01X KHDE01X
*Extra product *Extra product
4
3
2 4
1 3
2
1

COWELL® IMPLANT SYSTEM


Hex Driver > Used to insert or remove the Cover Screw, Healing Abutment and Abutment Screw etc.
> The Machine Drivers are used with contra angle, while the Ratchet Drivers are used with
the Torque Wrench.
H
Type Machine Torque Wrench > Torque control in implant placement and abutment connection.
Length
Hex
Hex 0.9 Hex 1.2 > Torque force 10, 25, 30 & 35 N.cm are able to be controlled by pulling the elastic bar.
> Maximal torque force 120 N.cm with pulling the rigid main bar.
22(Short) KMD09S KMD12S
28(Long) KMD09L KMD12L
Code KTW001

COWELL® DIGITAL PRODUCTS


*Extra product

H Type Ratchet
Hex
Length Hex 0.9 Hex 1.2
12(X-Short) - KHD1212
17(Short) KHD0915 KHD1215
23(Long) KHD0921 KHD1221
29(X-Long) KHD0927 KHD1227 Depth Gauge > Measuring the drill depth with scaled rod.
> Measuring the 5mm space between adjacent fixtures with flat end of the other side.

COWELL® EXPERT INSTRUMENTS


*Extra product


Code KDG001 






> One side of the Depth Gauge measures the drilling depth and the other side
measures the gingival height from the top of the implant.

REGENERATIVE SOLUTION
Code KDG004 ⲼExclusive for Sub.

COWELL®
116 SURGICAL KIT SURGICAL KIT 117
COWELLMEDI HISTORY
02
୔ Sloped edentulous ridge adjacent of tooth > Crestal cutter of the Initial Drill and Final Drill.
> Longer drills than fixture’s length.

Drilling Sequence E.g. 12mm Fixture

> Minimal drill frequency with the Point Drill, Ø2.2 Initial Drill and Final Drills > Length Marking
(Ø3.5, Ø4.0 and Ø4.5 Fixtures).
Ø2.2 Initial Drill Final Drill 12mm Drill 10mm Fixture
Crestal flatting Longer Final Drill

REID



୔ Wide extraction socket

 > Absence of the cortical bone & spongy bone.
 > Narrower diameter than the fixture’s diameter.


Ø2.2 Initial Drill Ø4.0 Drill Ø4.5 Fixture

COWELL® IMPLANT SYSTEM


Actual length of Drill : Fixture + 1mm ୔ Torque force control
> The 0.5mm deeper placement increases the initial torque force of fixture.
0.5mm deeper level.
Fixture Placement Level
Level Crestal Level 0.5mm Deeper Level
Density D1 D2 D3 D1 D2 D3
Torque 34.1 29 15.5 44.4 38.4 19.1

COWELL® DIGITAL PRODUCTS


> The pumping action of drill removes the bone chip in the hole.
> In dense bone, the debriment action decreases the high torque force.
Point Ø2.2 Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø6.0

Ø3.5 Pumping action of final drill for debriment


Density D1 D2 D3
Non- Debriment 34.1 29 19.6
Ø4.0
Debriment 30 25 15.5

Ø4.5

COWELL® EXPERT INSTRUMENTS


Ø5.0
୔ In weak bone quality 4 of maxillary tuberosity
> No pumping action.
Ø6.0
> 0.5mm deeper placement of fixture.
> Wider fixture than Final Drill.

> Ø5.0 fixture : a series of the Point Drill, Ø2.2 Initial Drill, Ø4.0 Final Drill and Ø5.0 Final Drill.
> Ø6.0 fixture : a series of the Point Drill, Ø2.2 Initial Drill, Ø4.0 Final Drill, Ø5.0 Final Drill and Ø6.0 Final Drill.
0.5mm deeper level.
Level Crestal level 0.5mm Deeper Level
Debriment with without with without
Ø4.5 Fixture 4.4 10.2 - 12.9

REGENERATIVE SOLUTION
Ø5.0 Fixture 11.6 19.9 14.1 24.5
Ø4.5 Drill Ø5.0 Fixture

COWELL®
ⲼThe Countersink and Tap Drill are used in hard bone quality.
*Extra product

118 SURGICAL KIT SURGICAL KIT 119


COWELLMEDI HISTORY
INNO SUB. SMART SURGICAL KIT [KSA002]
SUB. Length Marking & Stopper Actual Length of Drill : Fixture length + 1mm
> For the INNO Submerged Implant System (Sub. Ø3.5, 4.0, 4.5 & 5.0).
HEXAGON
SYSTEM > A simpler kit for implant surgery, applied to fixtures with 8~14mm in length using the Drills and Stoppers.

Diameter band Ø2.2


Ø3.5
Ø4.0
Ø4.5
Ø5.0



REID



8mm 10mm 12mm 14mm


Fixture Line Fixture Line Fixture Line Fixture Line

* While the 2.2 Initial Drill is used at 1,000 rpm with irrigation,
the Final Drills from the 3.5 to 5.0 should be used at 50 rpm without irrigation.

COWELL® IMPLANT SYSTEM


Drilling Sequence

Drill
Ø3.5
Point Ø2.2 Ø3.5 Countersink

COWELL® DIGITAL PRODUCTS


Normal Bone Hard Bone

Point Drill Ø2.2 Initial Drill Ø3.5 Final Drill Ø4.0 Final Drill Ø4.5 Final Drill Ø5.0 Final Drill
KPD01S 2KTD22 2KTD35 2KTD40 2KTD45 2KTD50 Ø4.0
Point Ø2.2 Ø4.0 Countersink

Stopper Countersink
Normal Bone Hard Bone

COWELL® EXPERT INSTRUMENTS


Ø4.5
Point Ø2.2 Ø3.5 Ø4.5 Countersink
8 Drill Stopper 10 Drill Stopper 12 Drill Stopper Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink
KSDS08S KSDS10S KSDS12S 4KCS35 4KCS40 4KCS45 4KCS50 Normal Bone Hard Bone

Extension & Driver

Ø5.0

Point Ø2.2 Ø4.0 Ø5.0 Countersink

REGENERATIVE SOLUTION
Normal Bone Hard Bone

COWELL®
Torque Wrench
Drill Extension M. Fixture Driver L R. Fixture Driver L 1.2 Hex Driver L 1.2 Hex Driver XL
KDE002 2KMMS01L 2KHDS01L KHD1221 KHD1227 KTW001

120 SURGICAL KIT SURGICAL KIT 121


COWELLMEDI HISTORY
INNO SUB-SHORT SURGICAL KIT [KSI001] Length Marking & Stopper Actual length of drill : Fixture + 0.5mm. Diameter band Ø2.0
Ø4.0
Ø4.5
Ø5.0
Ø5.5
SUB. 4 5.5 7 Ø6.0
HEXAGON > For the INNO Submerged Short Implant System (Sub.).
SYSTEM




4mm 5.5mm 7mm


Fixture Line Fixture Line Fixture Line

REID
Drilling Sequence
Normal Bone Hard Bone

Ø4.0
Point Ø2.0 Ø4.0 Countersink

COWELL® IMPLANT SYSTEM


A common tool for An exclusive tool for
the INNO Surgical Kits. the Short Implants.

Normal Bone Hard Bone

Drill

Ø4.5
Point Ø2.0 Ø4.0 Ø4.5 Countersink

A common tool for An exclusive tool for

COWELL® DIGITAL PRODUCTS


the INNO Surgical Kits. the Short Implants.

Point Drill Ø2.0 Step Drill Ø4.0 Step Drill Ø4.5 Step Drill Ø5.0 Step Drill Ø5.5 Step Drill Ø6.0 Step Drill
Normal Bone Hard Bone
KPD01S KSSD2004 KSSD4004 KSSD4504 KSSD5004 KSSD5504 KSSD6004

Stopper Countersink

Ø5.0
Point Ø2.0 Ø4.0 Ø4.5 Ø5.0 Countersink

A common tool for An exclusive tool for


the INNO Surgical Kits. the Short Implants.

COWELL® EXPERT INSTRUMENTS


Normal Bone Hard Bone
4mm Drill Stopper 5.5mm Drill Stopper 7mm Drill Stopper Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø5.5 Countersink Ø6.0 Countersink
SIDS04 SIDS05 SIDS07 4KCS40S 4KCS45S 4KCS50S 4KCS55S 4KCS60S

Extension & Driver


Ø5.5 Countersink
Point Ø2.0 Ø4.0 Ø4.5 Ø5.0 Ø5.5

A common tool for An exclusive tool for


the INNO Surgical Kits. the Short Implants.

Normal Bone Hard Bone

Torque Wrench
M. Mount Driver. L R. Mount Driver. L 1.2 Hex Driver L

REGENERATIVE SOLUTION
KMMD06L KRMD19L KHD1221 KTW001
Ø6.0 Point Ø2.0 Ø4.0 Ø4.5 Ø5.0 Ø5.5 Ø6.0 Countersink

COWELL®
A common tool for An exclusive tool for
the INNO Surgical Kits. the Short Implants.

122 SURGICAL KIT SURGICAL KIT 123


COWELLMEDI HISTORY
INNO SUB-NARROW SURGICAL KIT [KNA001] Fixture Driver
30.6
18

2.8 Type Ratchet Machine


SUB-N.
HEXAGON > For the INNO Submerged Narrow Implant System (Sub-N). Ratchet KHDS01XN KMMS01XN
SYSTEM
38.1

2.8

Machine
arrow K I T Ratchet X-Long Machine X-Long
12

10
Fixture Driver

REID
Drill Ø 3.3
Stopper Fixture
Mount Driver
8
Ø 3.1
Fixture

Ø 2.6 Type Ratchet Machine


Parallel Pin
Countersink KRMD19L KMMD12X
Ratchet Long
L
Ø 2.2
L > Used to install fixture. *Extra product
Spare
Point 1.2 Hex Driver
Depth Gauge
Ratchet Machine

COWELL® IMPLANT SYSTEM


Torque Wrench

Drill

Parallel Pin
21
Code KPP003

After Ø2.2 After Ø3.1 / Ø3.3


Drilling. Drilling.

COWELL® DIGITAL PRODUCTS


Point Drill Ø2.2 Twist Drill Ø2.6 Twist Drill Ø3.1 Twist Drill Ø3.3 Twist Drill
Cuff Height
KNPD20 KNSD22L KNSD26L KNSD31L KNSD33L

Stopper Countersink
Normal Bone
Drilling Sequence Hard Bone

COWELL® EXPERT INSTRUMENTS


8 Drill Stopper 10 Drill Stopper 12 Drill Stopper Ø3.1 Countersink Ø3.3 Countersink
KNDS08 KNDS10 KNDS12 4KCS31N 4KCS33N

Ø3.1
Extension & Driver Point Ø2.2 Ø2.6 Ø3.1 Ø3.1
Countersink Normal Bone

Hard Bone
Depth Gauge

KDG001

Torque Wrench
Fixture Driver(Ratchet) Fixture Driver(Machine) Parallel Pin 1.2 Hex Driver L

REGENERATIVE SOLUTION
KHDS01XN KMMS01XN KPP003 KHD1221 KTW001
Ø3.3
Point Ø2.2 Ø2.6 Ø3.3 Ø3.3
Countersink

COWELL®
124 SURGICAL KIT SURGICAL KIT 125
COWELL® PROSTHETIC KIT [KPA003]
SUB.
> For the INNO Submerged Implant System.
HEXAGON
SYSTEM > Try-in Kit for determining abutment specifications.

Mini Plus® Implant


Cement Type
SUB. HEXAGON
SYSTEM Prosthetic Kit Ball Type

Surgical kit

Abutment Gauge > Measuring of the diameter, cuff length and angulation of abutment.

7
5.5
4
4
2 3
1

Cuff 2 Cuff 4 15° / Cuff 2 15° / Cuff 4 25° / Cuff 2 25° / Cuff 4
2SAG002 2SAG004 2SAG152 2SAG154 2SAG252 2SAG254

Straight Type Angulated Type

Abutment Driver > Used in the Shoulder, Solid, Absolute, and Straight Abutment placement.

Shoulder Ø4.0 Shoulder Ø5.0 Hex 1.2 Ratchet Hex 1.2 Machine Tissue Punch
KRR19L KRW19L KHD1221 KMD12L KTP001 2 Pieces
Trephine soft tissue over
the Cover Screw of fixture.

126 SURGICAL KIT Mini Plus® Implant 127


COWELLMEDI HISTORY
System Flow
DESIGN OF MINI PLUS® FIXTURE (1P-C.)
Cement Type
>G For mandible anterior spaces and edentulous arch.
> For semi-permanent or temporary solution.

Fixture Protection Cap Impression Coping Lab Analog

REID
2
Implant
Top Anti-Rotation Square
> Promotes firm attachment to prosthetics.
> Direct impression is recommended when
2
modified/altered.
Diameter Diameter
Ø2.5 Ø3.0
Cuff Cuff

COWELL® IMPLANT SYSTEM


Length 2.0mm 4.0mm Length 2.0mm 4.0mm

10mm AMC2210S AMC2410S 10mm AMC3210S AMC3410S


5 12mm AMC2212S AMC2412S 12mm AMC3212S AMC3412S
14mm AMC2214S AMC2414S 14mm AMC3214S AMC3414S

Cutting Groove > Packing unit : 1 Fixture. > Packing unit : 1 Fixture.
> Two cutting grooves at 5mm, 7mm facilitates > Abutment level impression. > Abutment level impression.
alteration of height.

Cuff

Impression Coping / Lab Analog

COWELL® DIGITAL PRODUCTS


Impression Coping
> Packing unit : 1 Impression Coping.
Surface Treatment : SLA-SH®
> Fastened on the shoulder of the cement post and connected with
> Uniform micro-surface geometry, increased BIC
the Lab Analog for working cast.
and improved surface wetness.
> Direct impression is recommended when modified/altered.

Length
Lab Analog
Impression Coping Lab Analog

COWELL® EXPERT INSTRUMENTS


> Packing unit : 1 Lab Analog.
AMCI001 AMCL001
> The same adjustment must be made for the Lab Analog when the abutment
portion of the fixture is modified/altered.
> Replacement of the cement post shape in working mode.
Cutting edge allows Self-Tapping function

Protection Cap > Provides temporary protection of mucogingiva


and tongue after implantation.

Diameter Diameter
Length Ø4.0
Length
7mm AMCC001

REGENERATIVE SOLUTION
9mm AMCC002

Diameter 11mm AMCC003

COWELL®
> Packing unit : 1 Protection Cap.

128 Mini Plus® Implant Mini Plus® Implant 129


COWELLMEDI HISTORY
System Flow
DESIGN OF MINI PLUS® FIXTURE (1P-B.) Outer Cap Block-out Spacer
Ball Type
>G For semi-permanent or temporary solution for overdenture prosthesis. 2.4mm

Red : 10N Orange : 15N Green : 20N

Fixture Impression Coping Lab Analog Ball Inner Cap

REID
Implant

Diameter Diameter
Ø2.5 Ø3.0
Cuff Cuff
4.2 Easy delivery using the ball type drivers Length
2.0mm 4.0mm Length
2.0mm 4.0mm

COWELL® IMPLANT SYSTEM


10mm AMB2210S AMB2410S 10mm AMB3210S AMB3410S

12mm AMB2212S AMB2412S 12mm AMB3212S AMB3412S

14mm AMB2214S AMB2414S 14mm AMB3214S AMB3414S


Cuff
> Packing unit : 1 Fixture. > Packing unit : 1 Fixture.

Ball Outer Cap Diameter


Surface Treatment : SLA-SH® D Length Ø3.4

> Uniform micro-surface geometry, increased BIC 2.4 BATC003C

COWELL® DIGITAL PRODUCTS


L
and improved surface wetness. > Packing unit : 2 Outer Caps.

Length
Ball Inner Cap
Block-out Ball Inner Cap
Spacer BATC003I
> Packing unit : 2 Block-out Spacers + 6 Inner Caps (2 per each color).
> Retention force : Red 10N, Orange 15N & Green 20N.
Red : 10N Orange : 15N Green : 20N

COWELL® EXPERT INSTRUMENTS


Cutting edge allows Self-Tapping function

Impression Coping / Lab Analog


Diameter

Impression Coping
> Packing unit : 1 Impression Coping.
> Used for impression taking of the ball post.

Lab Analog

REGENERATIVE SOLUTION
Impression Coping Lab Analog
AMBI001 AMBL001 > Packing unit : 1 Lab Analog.
> Replacement of the ball post shape in working model.

COWELL®
130 Mini Plus® Implant Mini Plus® Implant 131
COWELLMEDI HISTORY
Tissue Punch
SURGICAL KIT [KMA003] KTP16
*Extra product

Ø2.35(Ø2.0 Implant)

KTP21 Ø2.85(Ø2.5 Implant)


6mm 4mm 2mm
KTP26 Ø3.35(Ø3.0 Implant)
> Easy removal of soft tissue for flapless
surgery.
KTP28 Ø3.55(Ø3.3 Implant) > 0.3mm wider than implant diameter
allows more predictable results.

REID
Point Drill
Multi Gauge *Extra product > Allows precise measurement of drilling depth and path.
36.8mm
KPD03L Length
30
20
10mm 8mm 5mm
(Ø3.0, Ø3.3 Implant) (Ø2.5 Implant) (Ø2.0 Implant) KDGP13 Ø1.3

COWELL® IMPLANT SYSTEM


Ø1.3 Twist Drill KDGP19 Ø1.9 18mm 16mm 14mm 12mm 10mm

KTWD13S Ø1.3 Ø2.0 Implant Final Drill

16mm 14mm 12mm 10mm


Drilling Sequence

COWELL® DIGITAL PRODUCTS


Ø1.8 Twist Drill Ø2.3 Twist Drill
Hard Bone
D1 / D2
KTWD18S Ø1.8 Ø2.5 Implant Final Drill
Ø2.5

Point Drill Ø1.8 Twist Drill Ø2.5 Implant (12mm)


16mm 14mm 12mm 10mm
Soft Bone
D3 / D4

Ø2.3 / Ø2.6 Twist Drill

COWELL® EXPERT INSTRUMENTS


KTWD23S Ø2.3 Ø3.0 Implant Final Drill

KTWD26S Ø2.6 Ø3.3 Implant Final Drill

Ø1.8 Twist Drill Ø2.6 Twist Drill


Hard Bone Hard Bone
16mm 14mm 12mm 10mm
D1 / D2 D1 / D2

Driver Ø3.0
Cement Type Ball Type
Point Drill Ø2.3 Twist Drill Ø3.0 Implant (12mm)

REGENERATIVE SOLUTION
Machine KMDC31L Machine KMDB27L
Soft Bone Soft Bone
D3 / D4 D3 / D4

COWELL®
Ratchet KRDC19L Ratchet KRDB19L
ⲼIn case of D4 bone quality, make proper adjustment in drilling. Due to narrow diameter,
the Mini Plus® Implants have self-tapping characteristic.

132 Mini Plus® Implant Mini Plus® Implant 133


COWELL® DIGITAL PRODUCTS COWELL®
DIGITAL
PRODUCTS
Drive yourself to COWELLMEDI’s Digital Transformation

Digital Guided Surgery Kit


InnoFit® Lodestar Plus Kit
InnoFit® Lodestar Kit

SFIT Ti-Base System


Digital Prosthesis
SFIT Ti-Base System InnoFit® Hybrid Ti-Base System
· Sub. SFIT Ti-Base System · Sub. Hybrid Ti-Base System
· Sub. SFIT Absolute Ti-Base System · Sub. Multi Hybrid Ti-Base System
· Sub. Multi SFIT Ti-Base System · Sub. Lock Hybrid Ti-Base System
· Int. SFIT Ti-Base System · Sub-N. Hybrid Ti-Base System
· Sub-N. Multi Hybrid Ti-Base System
· Int. Hybrid Ti-Base System Cementless Angulated screw channels Low prosthetic height
(Spread Fit™) in both anterior and posterior teeth

InnoFit® Lodestar Plus Kit InnoFit® Lodestar Kit

Exclusive for the INNO Submerged and Universal to any implant system.
Submerged Narrow Implant System.
COWELLMEDI HISTORY
InnoFit® Lodestar Plus Kit [KLSP001]

>G A total guided surgery solution applicable to various types of clinical cases.
>G Exclusive for the INNO Submerged and Submerged Narrow Implant System.

REID
Pilot Drill Pilot Drill Pilot Drill Pilot Drill Pilot Drill
(Ø3.1/3.3) (Ø3.5) (Ø4.0) (Ø4.5) (Ø5.0) Implant Adapter
KLPPD3307 KLPPD3308 KLPPD3310 KLPPD3312 KLPPD3314 KLPPD3507 KLPPD3508 KLPPD3510 KLPPD3512 KLPPD3514 KLPPD4007 KLPPD4008 KLPPD4010 KLPPD4012 KLPPD4014 KLPPD4507 KLPPD4508 KLPPD4510 KLPPD4512 KLPPD4514 KLPPD5007 KLPPD5008 KLPPD5010 KLPPD5012 KLPPD5014 KLPF01R KLPF02R KLPF01N KLPF02N

COWELL® IMPLANT SYSTEM


Tissue Punch Bone Flattening Drill Initial Drill (Ø2.8)
KLPTP01 KLPBF01 KLPID06S
Fixture Driver

COWELL® DIGITAL PRODUCTS


KLPFD21

Torque Wrench
KTW001LP

COWELL® EXPERT INSTRUMENTS


Drill Extension (KLSP001)
KDE002

12L

12L
08S

08S

REGENERATIVE SOLUTION
COWELL®
Hex Driver V Anchor Countersink Adapter Extension Abutment Profile
KLPHD1214 KLPHD1220 KLPVA00I KLPVA00B KLPCS31 KLPCS33 KLPCS35 KLPCS40 KLPCS45 KLPCS50 KLPRE08S KLPRE12L KLPME08S KLPME12L KLPAP10 KLPAP12 KLPAP14

136 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 137
COWELLMEDI HISTORY
Workflow Preparation before Operation

Consultation & Scan


Disinfection of surgical guide template
Fully digital
procedure Intraoral  
   
 
 
 
           

Dental Scanning  



  
 
 
    

 
  
       !

REID
Clinic
 !   

  "#   $  %    
 
    
Partially digital   &
 ' (
procedure Model
Patient CT Scanning Scanning

Installation of surgical guide template

COWELL® IMPLANT SYSTEM


Implant Simulation

+ )  %
     
%
      ( 
   

 %
%

          
  ,   !
Dental
Lab    -    
        

  (
+           %  $
)    
    

Fabrication - Abutment & Implant simulation & 
 
 
 .   
   ( 
 )  

 
 (
3D Printing & CAD/CAM crown design surgical guide template  $ %    

        /

COWELL® DIGITAL PRODUCTS


Fabrication

Verification of dental implant


Dental )  )          
 
Lab

Surgical guide template Temporary crown Customized abutment

COWELL® EXPERT INSTRUMENTS


Confirmation of protocol
Surgery

*    
    


 
    

Dental
Clinic

REGENERATIVE SOLUTION
COWELL®
138 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 139
COWELLMEDI HISTORY
Comprehension and Usage of Offset Tissue Punch > Used for soft tissue elimination (the gingiva in the position where the implant is to be
placed can be incised in a circular shape).
> The basic length from the fixture platform to the top of the Sleeve is 9mm. > Hemostatic effect, small scar, fast wound healing affect is occurred after the operation due
> In case that gingival is thick or fixture needs to be placed deeper due to low bone density, use the Sleeve 2 or 4mm upright to the top. to small diameter of tissue punch.
> The higher offset value, the less accurate it will be, so use 9mm if possible. > Able to apply offset (9mm, 11mm, 13mm).
> 50 rpm without irrigation.

27.1
Double blade
The internal cutting edge of the Tissue Punch cuts the gingival into small pieces so that those
13 can be removed by suction without extra work.

REID
Ø3.5
Ø5.2

KLPTP01

Tissue Punch Bone Flattening Drill

* Caution The Tissue Punch must be kept clean. Otherwise, it may cause rust or blade damage due to
Pilot Drill Countersink Implant Adapter
residual gingival pieces or others in the Tissue Punch after the operation

COWELL® IMPLANT SYSTEM


(remove the residual gingiva piece by explorer, steam and etc.).
Selection of theDrill according to the Sleeve
offset (In case of placing 8mm Fixture)
: In case of offset 9mm(0mm) – Select 8mm Drill.

Bone Flattening Drill > Flattens the bone level of operation site.
> Inclined bone level may glide the Drill and cannot drill as planned.
> Eliminate the soft tissue after using the Tissue Punch.
> The point in the middle of the Drill guides the position of the Drill and
helps to drill in an accurate site.
> Able to apply offset (9mm, 11mm, 13mm).
> 400 rpm without irrigation / 800 rpm with irrigation.

COWELL® DIGITAL PRODUCTS


Tissue Punch Bone Flattening Drill

Pilot Drill Countersink Implant Adapter


The point in the middle of the Drill guides the position of the Drill
Ø5.2 and helps to drill in an accurate site.
Selection of the Drill according to the Sleeve KLPBF01
offset (In case of placing 8mm Fixture)
: In case of offset 11mm(2mm) – Select 10mm Drill.

Initial Drill

COWELL® EXPERT INSTRUMENTS


> High speed, 1,000 rpm with irrigation.

Tissue Punch Bone Flattening Drill 4


9
Pilot Drill Countersink Implant Adapter

Point
6 Creates the hole on the bone surface so that the axis
* Caution Selection of the Drill according to the Sleeve

REGENERATIVE SOLUTION
offset (In case of placing 8mm Fixture) of the next step Drill is not moved and it guides the Drill
Please be noted that actual depth of drilling is 1mm deeper
: In case of offset 13mm(4mm) – Select 12mm Drill. position by preventing slip even at the inclined bone level.
than marks of the Drill. Ø2.15

COWELL®
Ex) 4.0 X 8mm Drill - Drilling depth : 9mm. Ø2.8

KLPID06S

140 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 141
COWELLMEDI HISTORY
Pilot Drill > Low speed, 50 rpm without irrigation / 50 N.cm

Ø3.1/Ø3.3 Fixture Ø4.5 Fixture


KLPPD3307 KLPPD3308 KLPPD3310 KLPPD3312 KLPPD3314 KLPPD4507 KLPPD4508 KLPPD4510 KLPPD4512 KLPPD4514

H : 32 H : 33 H : 35 H : 37 H : 39
H : 32 H : 33 H : 35 H : 37 H : 39

REID
4
4
9
9

4.3
3.2
3.9
2.8 8
8 9
9 3.5 10
2.15 10 11
11 12
12 13
13 14
14 15
15

COWELL® IMPLANT SYSTEM


Ø3.5 Fixture Ø5.0 Fixture
KLPPD3507 KLPPD3508 KLPPD3510 KLPPD3512 KLPPD3514 KLPPD5007 KLPPD5008 KLPPD5010 KLPPD5012 KLPPD5014

H : 32 H : 33 H : 35 H : 37 H : 39 H : 32 H : 33 H : 35 H : 37 H : 39

COWELL® DIGITAL PRODUCTS


4 4
9 9

3.5 4.9
3.2 4.3
8 8
9 10 3.9 9 10
2.8
11 11
12 12
13 13
14 14
15 15

COWELL® EXPERT INSTRUMENTS


Ø4.0 Fixture
KLPPD4007 KLPPD4008 KLPPD4010 KLPPD4012 KLPPD4014

H : 32 H : 33 H : 35 H : 37 H : 39

4
9

3.9
3.5

REGENERATIVE SOLUTION
8
9 10
3.2
11
12
13

COWELL®
14
15

142 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 143
COWELLMEDI HISTORY
Countersink > Expand the cortical bone in D1/D2 bone to prevent excessive implantation of the fixture. Fixture Driver - Molar > Use in case the Implant Adapter can not be used due to small size of opened mouth or
> Able to apply offset (9mm, 11mm, 13mm). narrow gap between antagonist tooth.
> 50 rpm without irrigation. > After implanting 4~5mm, change to the Implant Adapter to complete placement.

KLPCS31 KLPCS33 KLPCS35 KLPCS40 KLPCS45 KLPCS50

13mm
11mm

REID
9mm 4~5

KLPFD21 ⴘ Place 4~5mm. ⴙ Change to the ⴚ Complete placement.


Implant Adapter.
Ø3.1 Ø3.3 Ø3.5 Ø4.0 Ø4.5 Ø5.0

COWELL® IMPLANT SYSTEM


Adapter Extension > In case the Implant Adapter is too short to use, connect the Ratchet or Abutment Profile > Used for elimination of the alveolar bone that interferes with the accurate connection of
Machine Adapter Extension to place the fixture. abutment. Remove residual bone by rotating and drilling 360°.
> In case of thick cortical bone, higher the drilling rpm and use with irrigation (within 100 rpm).

08S Adapter
Extension
Implant
Adapter

13mm
11mm
12L

12L

12 12 9mm
08S

08S

COWELL® DIGITAL PRODUCTS


8 8

Ratchet-Short Ratchet-Long Machine-Short Machine-Long


KLPRE08S KLPRE12L KLPME08S KLPME12L

Implant Adapter
KLPAP10 KLPAP12 KLPAP14
> Move fixture to the Sleeve to implant safely. Before use After use

> Match the depth of laser marks of the Sleeve offset and Implant Adapter.
> When implanting the fixture, the direction of the Implant Adapter and directional identification Groove for Removal

COWELL® EXPERT INSTRUMENTS


In case of cold welding,
groove of the Sleeve are matched, it lines with the hex direction of temporary abutment.
hang the crown remover
> In case the Implant Adapter cannot be removed by cold welding after placing the fixture, on the groove to remove.
hang the crown remover on the groove to remove.

O-ring Color
Regular - Red
Narrow - Yellow
13mm
11mm Hex-directional
9mm
identification
groove.

REGENERATIVE SOLUTION
Regular-Stop Regular-No Stop Narrow-Stop Narrow-No Stop

COWELL®
KLPF01R KLPF02R KLPF01N KLPF02N

144 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 145
COWELLMEDI HISTORY
V Anchor - Fix Fixture > Connect the 1.2 Hex Driver to implanted fixture to prevent the movement of the Torque Wrench(Square) > Use to implant the fixture (Connect to the Implant Adapter).
surgical guide template in cases as edentulous. > Use after connecting to the 1.2 Hex Driver.
> Use after connecting to the V Anchor (Fix Bone).

13mm
11mm
9mm Torque Wrench KTW001LP

9mm 11mm 13mm

REID
KLPVA00I KLPVA02I KLPVA04I
Extra Extra * Caution
- Connect by aligning to the Sleeve offset of connected fixture.
- Basic composition of the Sleeve offset 9mm (11, 13mm extra).

V Anchor - Fix Bone > Fix the V Anchor using the Torque Wrench in the hole made after initial drilling to Extra

COWELL® IMPLANT SYSTEM


Sleeve
prevent the movement of the surgical guide template in cases as edentulous.

3
13mm
11mm Ø5
9mm

9mm 11mm 13mm

COWELL® DIGITAL PRODUCTS


Ø5.3 Ø5.3
KLPVA00B KLPVA02B KLPVA04B Ø6.1 Ø6.1

Extra Extra * Caution


Closed Sleeve Open Sleeve Hex-directional
KLPS01 KLPS02 identification groove.
- Connect by aligning to the Sleeve offset of connected fixture.
- Basic composition of the Sleeve offset 9mm (11, 13mm extra). * Packing Unit : 5 Sleeves * Packing Unit : 5 Sleeves

Ratchet 1.2 Hex Driver > Use in case of connecting the Cover Screw or Healing Abutment.

COWELL® EXPERT INSTRUMENTS


Connect the Adapter
Extension if necessary.
20

14

KLPHD1214 KLPHD1220

REGENERATIVE SOLUTION
COWELL®
146 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 147
COWELLMEDI HISTORY
Drill Protocol

* Drilling method - Make sure with drilling in a desired direction without a change in path through the primary drill contact (A) with the hole created
by the previous drilling and the secondary contact (B) with the sleeve.
- Create the hole using the initial drill and insert the next drill into the hole made during the previous step and drill after achieving

REID
Drill Protocol (7~10mm) the drill and sleeve contact (A&B).
INNO Sub Fixture Ø5 x 10mm - If drilling only with the sleeve contact (B) without the drill contact (A), the path may not be correct.

Bone
Tissue Punch Flattening Initial Ø3.3 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Countersink Abutment
Drill Profile

COWELL® IMPLANT SYSTEM


B B

A A

Hard Bone

A &TKNNEQPVCEV  B 5NGGXGEQPVCEV 

COWELL® DIGITAL PRODUCTS


Drill Protocol(12~14mm)
INNO Sub Fixture Ø5 x 14mm * Precaution when irrigating

- Irrigate enough to the end of the drill hole.

Bone
Tissue Punch Flattening Initial Ø3.3 X 10 Ø3.3 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14 Countersink Abutment
Drill Profile

COWELL® EXPERT INSTRUMENTS


Hard Bone
X
8~10mm drilling should be done
in advance for the sleeve contact.

REGENERATIVE SOLUTION
COWELL®
148 InnoFit® Lodestar Plus Kit InnoFit® Lodestar Plus Kit 149
COWELLMEDI HISTORY
InnoFit® Lodestar Kit [KLS001]

>G A cost-effective guided surgery solution applicable to various types of clinical cases.
>G Universal to any implant system.

Ø2.0 X 7 Ø2.0 X 8 Ø2.0 X 10 Ø2.0 X 12 Ø2.0 X 14 Ø2.7 X 7 Ø2.7 X 8 Ø2.7 X 10 Ø2.7 X 12 Ø2.7 X 14 Ø3.4 X 7 Ø3.4 X 8 Ø3.4 X 10 Ø3.4 X 12 Ø3.4 X 14 Ø4.2 X 7 Ø4.2 X 8 Ø4.2 X 10 Ø4.2 X 12 Ø4.2 X 14

REID
Pilot Drill(Ø2.0) Pilot Drill(Ø2.7) Pilot Drill(Ø3.4) Pilot Drill(Ø4.2)

COWELL® IMPLANT SYSTEM


KLSPD2007 KLSPD2008 KLSPD2010 KLSPD2012 KLSPD2014 KLSPD2707 KLSPD2708 KLSPD2710 KLSPD2712 KLSPD2714 KLSPD3407 KLSPD3408 KLSPD3410 KLSPD3412 KLSPD3414 KLSPD4207 KLSPD4208 KLSPD4210 KLSPD4212 KLSPD4214

COWELL® DIGITAL PRODUCTS


Tissue Punch
KLSTP45
Anchor System
KLSAD13 KLSAS18 KLSMD23 KLSRD16

COWELL® EXPERT INSTRUMENTS


10mm 12,14mm (KLS001)

10mm 12mm 14mm


Stopper

Initial Drill
KLSID18 KLSID18L

REGENERATIVE SOLUTION
COWELL®
Abut. Profile Drill Drill Extension
KLSPD10 KLSPD12S KLSPD14 KDE002

150 InnoFit® Lodestar Kit InnoFit® Lodestar Kit 151


COWELLMEDI HISTORY
Tissue Punch > The gingiva in the position where the implant is to be placed can be incised in a circular shape, Pilot Drill > Ø2.0 / Ø2.7 / Ø3.4 / Ø4.2.
and it can also be used in inclined bones (50 rpm without irrigation).

Ø2.0 : High Speed - 600 rpm

14.1

The gingiva can be incised in a circular shape although


bone level is inclined or not parallel.

REID
10
10
12.1 10
10 10 23
19 21
16 17

9
6 7 11 13
Ø4
Ø4.45
The internal cutting edge of the Tissue Punch cuts the

COWELL® IMPLANT SYSTEM


gingiva into small pieces so that those can be removed Pilot Drill 16mm(6mm) Pilot Drill 17mm(7mm) Pilot Drill 19mm(9mm) Pilot Drill 21mm(11mm) Pilot Drill 23mm(13mm)
KLSTP45 by suction without extra work. Ø4 KLSPD2007 KLSPD2008 KLSPD2010 KLSPD2012 KLSPD2014

Ø2.7 / Ø3.4 / Ø4.2 : Low Speed - 50~200 rpm / 50 N.cm

Initial Drill > The Drill combined with Bone Flattening Drill and Point Drill which no separate Bone Flattening Drill is

COWELL® DIGITAL PRODUCTS


required provides simper procedure and shorter chair time (1,000 rpm with irrigation).

10
10
10
10
10 25
23
21
17 19
15
11 13

COWELL® EXPERT INSTRUMENTS


7 9

14 12 10 Pilot Drill 17mm(7mm) Pilot Drill 19mm(9mm) Pilot Drill 21mm(11mm) Pilot Drill 23mm(13mm) Pilot Drill 25mm(15mm)
10
Bone Flattening
KLSPD2707 KLSPD2708 KLSPD2710 KLSPD2712 KLSPD2714
Flattens uneven
Point surface of alveolar crest.
6 6
KLSPD3407 KLSPD3408 KLSPD3410 KLSPD3412 KLSPD3414
Creates the hole on the bone surface
so that the axis of the next step Drill is KLSPD4207 KLSPD4208 KLSPD4210 KLSPD4212 KLSPD4214
not moved and it guides the Drill position
by preventing slip even at the inclined bone level.
KLSID18 KLSID18L

REGENERATIVE SOLUTION
COWELL®
152 InnoFit® Lodestar Kit InnoFit® Lodestar Kit 153
COWELLMEDI HISTORY
Abutment Profile > Used for elimination of the alveolar bone that interferes with * Offset length setting
the accurate connection of abutment.
- The basic length from the fixture platform to the top of the Sleeve is 10mm.
- In case that gingival is thick or fixture needs to be placed deeper due to low bone density,
use the Sleeve 2 or 4mm upright to the top.
- The higher offset value, the less accurate it will be, so use 10mm if possible.

KLSPD10 KLSPD14 + KLSPD12S KLSPD14 KLSPD12S 10mm 12mm 14mm


6.9

REID
5.2
14mm
16
12mm
10mm

COWELL® IMPLANT SYSTEM


9.8
11.8 13.8
2 11.8
Ø4

* Mount Stopper on the 14mm Drill to


use as the 12mm Drill.
Offset - 10mm Offset - 12mm Offset - 14mm

COWELL® DIGITAL PRODUCTS


Anchor System

Ø4.5

5
15
* Remove residual bone by rotating
and drilling 360° along the inside

COWELL® EXPERT INSTRUMENTS


20
of the Sleeve. 33 23 23.2 23.5
If the cortical layer is thick, increase the drilling
speed in the range of 1,000 rpm with irrigation. 8.5 18
16.5
14
12
10

9.5 3.2

Ø4.3

Ø1.3
Anchor Drill Anchor Screw Anchor Driver Anchor Driver

KLSAD13 KLSAS18 KLSMD23 KLSRD16

REGENERATIVE SOLUTION
COWELL®
154 InnoFit® Lodestar Kit InnoFit® Lodestar Kit 155
COWELLMEDI HISTORY
Optional > These products are optional as extra ones which are not included in the kit. Sleeve Extra

5.3 5.3
Ø4.5 Ø4.5

1mm
Guide Reamer Extra
Ø4.3
4mm
Used for precise contact of Drill and Sleeve (Sleeve / Non Sleeve). 90˚
Use the 4.5mm Guide Reamer for Non Sleeve, and the 5.3 Guide Reamer for Sleeve (800 rpm without irrigation).

REID
Ø5.3 Ø5.3
Closed Sleeve Open Sleeve
Guide Reamer Guide Reamer
(Non Sleeve) (Sleeve) KLSS01 KLSS02
KLSRD45 KLSRD53
* Packing Unit : 5 Sleeves * Packing Unit : 5 Sleeves Hex-directional
15mm 15mm identification groove.

31mm 31mm

COWELL® IMPLANT SYSTEM


4.5mm 5.3mm
16mm
16mm

Pilot Drill – 16/18mm Extra

18mm 18mm 18mm


16mm 16mm 16mm

COWELL® DIGITAL PRODUCTS


Non Sleeve Sleeve
10 10 10
KLSRD45 KLSRD53
29 29 29

Ⱍ
19 19 19
Ⱍ 17 17
17

KLSPD2018 KLSPD2718 KLSPD3418


Ø4.5 Below Ø5.3 Below
(Imprecise hole after (Imprecise hole after
the guided template the guided template

COWELL® EXPERT INSTRUMENTS


fabrication) fabrication)
Revises imprecisely formed hole after the guided template Revises imprecisely formed hole after the guided template
fabrication using the 4.5 Guide Reamer to create the hole to be in fabrication using the 5.3mm Guide Reamer to precisely insert the Sleeve.
exact contact with the Drill.

10mm 10mm

17mm 19mm

REGENERATIVE SOLUTION
COWELL®
16mm Fixture 18mm Fixture

156 InnoFit® Lodestar Kit InnoFit® Lodestar Kit 157


COWELLMEDI HISTORY
* The 14mm Drill must be used after using the 10mm Drill to enable Sleeve contact
For the use of the 14mm Drill with exact contact to the Sleeve, use the Ø2.0x10mm Drill first before using the 14mm Drill.

Drilling Sequence
e.g.) 3.4 X 14mm Drilling Sequence
Final drill of Countersink Tap Drill Placement
*OJUJBM Ⱍ9 Ⱍ9 Ⱍ9 Ⱍ9 each system 

Drill Protocol (Non Sleeve)




Reamer
*OJUJBM     Final drill of Countersink Tap Drill Placement

(Ø4.5) each system


REID
Offset
2
2
10

*Extra With the guided template mounted After removal of the guided template

COWELL® IMPLANT SYSTEM


Ø2.5~Ø3.0 Ø3.3/Ø3.5 Ø4.0/Ø4.5 Ø5.0/Ø6.0
* Drilling method
Fixture Fixture Fixture Fixture
- Make sure with drilling in a desired direction without a change in path through the primary Drill contact (A) with the hole
With the guided template mounted After removal of the guided template created by the previous drilling and the secondary contact (B) with the Sleeve.
- Create the hole using the Initial Drill and insert the next drill into the hole made during the previous step and Drill after
achieving the Drill and Sleeve contact (A&B).
- If drilling only with the Sleeve contact (B) without the Drill contact (A), the path may not be correct.

Drill Protocol (Sleeve)

COWELL® DIGITAL PRODUCTS


Reamer Final drill of Countersink Tap Drill Placement
(Ø5.3)
*OJUJBM     each system



B B

Offset
2
2 A A

10

*Extra

A &TKNN%QPVCEV B 5NGGXG%QPVCEV

COWELL® EXPERT INSTRUMENTS


Ø2.5~Ø3.0 Ø3.3/Ø3.5 Ø4.0/Ø4.5 Ø5.0/Ø6.0
Fixture Fixture Fixture Fixture
* Precaution when irrigating
With the guided template mounted After removal of the guided template
- Irrigate enough to the end of the drill hole.

REGENERATIVE SOLUTION
COWELL®
X
158 InnoFit® Lodestar Kit InnoFit® Lodestar Kit 159
COWELLMEDI HISTORY
Component selection guide for Intra-oral scanning Component selection guide for • Model-scanning
procedure • Handwork procedure
the Sub. SFIT Ti-Base System the Sub. SFIT Ti-Base System
SUB. SUB.
HEXAGON HEXAGON
SYSTEM SYSTEM

REID
Prosthesis

Prosthesis

(Hex) (N-Hex) (Hex) (N-Hex)

COWELL® IMPLANT SYSTEM


SFIT Titanium SFIT Meta G
(Hex) (N-Hex) (Hex) (N-Hex) Cylinder UCLA Cylinder
SFIT S Ti-Base SFIT A Ti-Base SFIT Ti-Base
Setting Screw

(Hex) (N-Hex) (Hex) (N-Hex)

SFIT S Ti-Base SFIT A Ti-Base SFIT Ti-Base


Setting Screw

(Hex) (N-Hex) (Hex) (N-Hex)

SFIT S Ti-Base SFIT A Ti-Base


Scanbody

COWELL® DIGITAL PRODUCTS


Model scanning Handwork
Digital Analog

Digital Analog

COWELL® EXPERT INSTRUMENTS


Scanbody

(Short) (Long) (X-Long) (Hex) (N-Hex) (Hex) (N-Hex)


Bite Impression Coping Pick-up Impression Coping Transfer Post

Healing
Fixture Fixture Cover Screw Abutment
Submerged Short

REGENERATIVE SOLUTION
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short

COWELL®
160 SFIT Ti-Base System : Sub. SFIT Ti-Base SFIT Ti-Base System : Sub. SFIT Ti-Base 161
COWELLMEDI HISTORY
SFIT S Ti-Base 1.2 Hex SFIT S Ti-Base Screw SFIT Ti-Base Cuff 1 2 3 4
Height 10.6 11.6 12.6 13.6
D 2.3 1.2 Hex Diameter
Type Hex N-Hex
L Ø2.3 2SSFS10S35 2SSFS20S35 2SSFS30S35 2SSFS40S35
Diameter Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5 2.3
C
Length > Packing unit: 1 SFIT S Ti-Base Screw.
Cuff 3.6 3.6 3.6 3.6 3.6 3.6
> Used to connect the SFIT S Ti-Base.
1 2SSFH38135 2SSFH45135 2SSFH55135 2SSFN38135 2SSFN45135 2SSFN55135 H
Ø3.8 Ø4.5 Ø5.5 2SSFS10S35: SFIT S Ti-Base with Cuff 1, 2SSFS20S35: SFIT S Ti-Base with Cuff 2,
2 2SSFH38235 2SSFH45235 2SSFH55235 2SSFN38235 2SSFN45235 2SSFN55235 2SSFS30S35: SFIT S Ti-Base with Cuff 3, 2SSFS40S35: SFIT S Ti-Base with Cuff 4.
3 2SSFH38335 2SSFH45335 2SSFH55335 2SSFN38335 2SSFN45335 2SSFN55335 > Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
Hex 4 2SSFH38435 2SSFH45435 2SSFH55435 2SSFN38435 2SSFN45435 2SSFN55435

REID
L
> Packing unit: 1 SFIT S Ti-Base + 1 SFIT S Ti-Base Screw.
> For Screw Retained Prosthesis with straight screw channel.
C
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Connected with the SFIT S Ti-Base Screw.
Ø3.8 Ø4.5 Ø5.5
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
> Use the SFIT Scanbody for digital workflow.
N-Hex > Fixture level impression.

COWELL® IMPLANT SYSTEM


SFIT A Ti-Base Screw SFIT Ti-Base Cuff 1 2 3 4
Height 10.6 11.6 12.6 13.6
1.8 Stargrip Diameter
Ø2.3 2SSFS10A35 2SSFS20A35 2SSFS30A35 2SSFS40A35
2.3
> Packing unit: 1 SFIT A Ti-Base Screw.
> Used to connect the SFIT A Ti-Base.
H
2SSFS10A35: SFIT A Ti-Base with Cuff 1, 2SSFS20A35: SFIT A Ti-Base with Cuff 2,
SFIT A Ti-Base 1.8 Stargrip 2SSFS30A35: SFIT A Ti-Base with Cuff 3, 2SSFS40A35: SFIT A Ti-Base with Cuff 4.
> Tightened with the Angulated Screw Ratchet Driver and Torque Wrench.
D 2.3
Type Hex N-Hex
L
Diameter Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5
C
Length

COWELL® DIGITAL PRODUCTS


Cuff 3.6 3.6 3.6 3.6 3.6 3.6
1 2SSFH38135A 2SSFH45135A 2SSFH55135A 2SSFN38135A 2SSFN45135A 2SSFN55135A
Ø3.8 Ø4.5 Ø5.5
2 2SSFH38235A 2SSFH45235A 2SSFH55235A 2SSFN38235A 2SSFN45235A 2SSFN55235A
3 2SSFH38335A 2SSFH45335A 2SSFH55335A 2SSFN38335A 2SSFN45335A 2SSFN55335A
Hex 4 2SSFH38435A 2SSFH45435A 2SSFH55435A 2SSFN38435A 2SSFN45435A 2SSFN55435A

L
> Packing unit: 1 SFIT A Ti-Base + 1 SFIT A Ti-Base Screw.
> For Screw Retained Prosthesis with angulated screw channel.
C
> Gold color for more translucent restoration.
Angulated Screw > Library available for EXOCAD®, 3Shape® & others. Scanbody Type Hex
Ratchet Driver
> Connected with the SFIT A Ti-Base Screw. D
Ø3.8 Ø4.5 Ø5.5

COWELL® EXPERT INSTRUMENTS


> Tightened with the Angulated Screw Ratchet Driver and Torque Wrench. 1.2 Hex. Diameter Ø4.3
> Tightening torque force: 30 N.cm. Length
8
> Use the SFIT Scanbody for digital workflow. Cuff
L 2.45
N-Hex > Fixture level impression. 2 2SSB4329

C > Packing unit: 1 Scanbody + 1 Abutment Screw (2SSHR100).


> For both intra-oral scanning and model-scanning.
* Angulated Screw Ratchet Driver > Made of 100% titanium alloy with a special coating applied.
Type Ratchet > No need to spray.
Height
> Connected with the Abutment Screw (2SSHR100).
24(Short) KRBUD15
Hex > Tightened with the 1.2 Hex Driver and Torque Wrench.
29(Long) KRBUD20
> Tightening torque force: 12~15 N.cm.
H
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and
the dedicated Stargrip Abutment Screw.
> Tightening torque force : 30 N.cm (50 N.cm Max.).

REGENERATIVE SOLUTION
COWELL®
162 SFIT Ti-Base System : Sub. SFIT Ti-Base SFIT Ti-Base System : Sub. SFIT Ti-Base 163
COWELLMEDI HISTORY
Bite Impression Coping Digital Analog
Type Hex(Short) Hex(Long) Hex(X-Long)
D D Diameter
Diameter Ø4.5 Ø4.5 Ø4.5 Height Ø3.9
L Cuff 12 2SDR001
Length 2 4 6
H
4.0 2SBIC45S 2SBIC45L 2SBIC45X > Packing unit: 1 Digital Analog.
C
> Analog of fixture for working cast.
> Packing unit: 1 Bite Impression Coping + 1 Guide Guide Pin (inbuilt). > Used for both 3D printed model (RP) and stone model.
> Designed to simultaneously take bite and impression.
> For closed tray impression (bite impression).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
(Short) (Long) (X-Long)
> Tightening torque force: 12~15 N.cm.

REID
Hex
SFIT Ti-Base Setting Screw
Diameter
Height Ø1.95
1.2 Hex
8.2 2SSFSS100
1.95
> Packing unit: 5 SFIT Ti-Base Setting Screws.
> Used to screw the SFIT S or A Ti-Base into the Digital Analog or the Fixture when revising such prosthetic
Pick-up Impression Coping Type Hex N-Hex
H adaptions as shape, contact surface, occlusion and margin without giving a force to the head of the
SFIT Ti-Base S or A Ti-Base to spread and fit in the inner space of the prosthesis.

COWELL® IMPLANT SYSTEM


D Diameter > Tightened with the 1.2 Hex Ratchet Driver.
Length / Cuff Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5
14 (Short) / 4 2SIH454S 2SIH554S 2SIH654S 2SIN454S 2SIN554S 2SIN654S
14 (Short) / 2 2SIH45S 2SIH55S 2SIH65S 2SIN45S 2SIN55S 2SIN65S
L
16 (Long) / 4 2SIH45L 2SIH55L 2SIH65L 2SIN45L 2SIN55L 2SIN65L

C > Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (2SISR001SS / 2SISR001SL).
> For open tray impression.
> Connected with the Guide Pin. SFIT Titanium Cylinder
(Short) (Short) (Long) (Short) (Short) (Long) > Tightened with the 1.2 Hex Driver and Torque Wrench. Type Crown Bridge
SFIT Ti-Base
2 Pieces Diameter Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5
H Diameter
Height Ø4.1 Ø4.8 Ø5.8 Ø4.1 Ø4.8 Ø5.8
Hex N-Hex
7 2SSFTC3835H 2SSFTC4535H 2SSFTC5535H 2SSFTC3835N 2SSFTC4535N 2SSFTC5535N

COWELL® DIGITAL PRODUCTS


D

> Packing unit: 1 SFIT Titanium Cylinder.


> Used over both SFIT S or A Ti-Base and SFIT Absolute S or A Ti-Base.
Crown Bridge > For provisional and permanent restorations.
> Connected with the SFIT S or A Ti-Base Screw and SFIT Absolute S or A Ti-Base Screw.
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.

COWELL® EXPERT INSTRUMENTS


Transfer Post SFIT Meta G UCLA Cylinder
D Type Hex N-Hex
Type Crown Bridge
Diameter
Length / Cuff Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5 SFIT Ti-Base
Diameter Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5
L 9 (Short) / 2 2STH45S 2STH55S 2STH65S 2STN45S 2STN55S 2STN65S H Diameter
Height Ø4.3 Ø5 Ø5.7 Ø4.3 Ø5 Ø5.7
11 (Long) / 4 2STH45L 2STH55L 2STH65L 2STN45L 2STN55L 2STN65L
11.4 2SSFC3835C 2SSFC4535C 2SSFC5535C 2SSFC3835B 2SSFC4535B 2SSFC5535B
C
> Packing unit: Hex - 1 Transfer Post + 1 Guide Pin (Short: 2STH001SS / Long: 2STH001SL), D
N-HeX – 1 Transfer Post (solid screw). > Packing unit: 1 SFIT Meta G UCLA Cylinder.
(Short) (Long) (Short) (Long)
> For open tray impression. > Used over both SFIT S or A Ti-Base and SFIT Absolute S or A Ti-Base.
> Connected with the Guide Pin. Crown Bridge > Modifiable to various types of abutments.
2 Pieces 1 Piece > Tightened with the 1.2 Hex Driver and Torque Wrench. > CCM alloy core for precise connection.
> Tightening torque force: 12~15 N.cm. > Cast with non-precious metal or gold alloy.
> Connected with the SFIT S or A Ti-Base Screw and SFIT Absolute S or A Ti-Base Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench.

REGENERATIVE SOLUTION
> Tightening torque force: 30 N.cm.
Hex N-Hex

COWELL®
164 SFIT Ti-Base System : Sub. SFIT Ti-Base SFIT Ti-Base System : Sub. SFIT Ti-Base 165
COWELLMEDI HISTORY
Component selection guide for Intra-oral scanning Component selection guide for • Model-scanning
procedure • Handwork procedure
the Sub. SFIT Absolute Ti-Base System the Sub. SFIT Absolute Ti-Base System
SUB. SUB.
HEXAGON HEXAGON
SYSTEM SYSTEM

REID
Crown

Crown

COWELL® IMPLANT SYSTEM


(Hex) (N-Hex) (Hex) (N-Hex)

SFIT Absolute SFIT Titanium SFIT Meta G


Scanbody Cylinder UCLA Cylinder

Model scanning Handwork

SFIT Absolute Digital Analog

SFIT Absolute Digital Analog

COWELL® DIGITAL PRODUCTS


SFIT Absolute Scanbody

(Hex) (N-Hex) (Hex) (N-Hex)

SFIT Absolute SFIT Absolute


Pick-up Impression Coping Transfer Post

COWELL® EXPERT INSTRUMENTS


SFIT Absolute S Ti-Base SFIT Absolute A Ti-Base

SFIT Absolute S Ti-Base SFIT Absolute A Ti-Base

Healing
Fixture Fixture Cover Screw Abutment
Submerged Short

REGENERATIVE SOLUTION
COWELL®
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short

166 SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base 167
COWELLMEDI HISTORY
SFIT Absolute S Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5 SFIT Absolute S Ti-Base Screw Diameter
Height Ø2.3
D Length
1.2 Hex Cuff 3.6 3.6 3.6 1.2 Hex 4.1 2SSFS100S
L
1 2SSF38135 2SSF45135 2SSF55135
C 2.3
2.3 > Packing unit: 1 SFIT Absolute S Ti-Base Screw.
2 2SSF38235 2SSF45235 2SSF55235
H
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
3 2SSF38335 2SSF45335 2SSF55335
Ø3.8 Ø4.5 Ø5.5 4 2SSF38435 2SSF45435 2SSF55435

> Packing unit: 1 SFIT Absolute S Ti-Base + 1 SFIT Absolute S Ti-Base Screw.
> For Screw Retained Prosthesis with straight screw channel.
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.

REID
> Integrated with the Screw and Ti-Base (solid screw).
> Tightened with the 1.2 Hex Ratchet Driver or Absolute Ratchet Driver and Torque Wrench.
> Prosthesis is connected to the SFIT Absolute S Ti-Base by the SFIT Absolute S Ti-Base Screw using
the 1.2 Hex Ratchet Driver.
> Tightening torque force: 30 N.cm.
> Use the SFIT Absolute Scanbody for digital flow.
> Abutment level impression.

COWELL® IMPLANT SYSTEM


SFIT Absolute A Ti-Base Screw Diameter
Height Ø2.3
1.8 Stargrip 4.1 2SSFS100A

2.3 > Packing unit: 1 SFIT Absolute A Ti-Base Screw.


H
> Tightened with the Angulated Screw Ratchet Driver and Torque Wrench.

SFIT Absolute A Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5


D Length
1.8 Stargrip Cuff 3.6 3.6 3.6
L
1 2SSF38135A 2SSF45135A 2SSF55135A
C 2.3
2 2SSF38235A 2SSF45235A 2SSF55235A

COWELL® DIGITAL PRODUCTS


3 2SSF38335A 2SSF45335A 2SSF55335A
Ø3.8 Ø4.5 Ø5.5 4 2SSF38435A 2SSF45435A 2SSF55435A

Angulated Screw
Ratchet Driver > Packing unit: 1 SFIT Absolute A Ti-Base + 1 SFIT Absolute A Ti-Base Screw.
> For Screw Retained Prosthesis with angulated screw channel.
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Integrated with the Screw and Ti-Base (solid screw).
> Tightened with the 1.2 Hex Ratchet Driver or Absolute Ratchet Driver and Torque Wrench.
> Prosthesis is connected to the SFIT Absolute A Ti-Base by the SFIT Absolute A Ti-Base Screw using
the Angulated Screw Ratchet Driver.
> Tightening torque force: 30 N.cm.
SFIT Absolute Ratchet Driver
Type Crown
> Use the SFIT Absolute Scanbody for digital flow. H

COWELL® EXPERT INSTRUMENTS


SFIT Absolute
> Abutment level impression. Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5
Diameter
D Height Ø4.2 Ø4.8
* Angulated Screw Ratchet Driver 19 KSFR3812S KSFR4512S

Height
Type Ratchet 26 KSFR3819L KSFR4519L
24(Short) KRBUD15
29(Long) KRBUD20 > Packing unit: 1 SFIT Absolute Ratchet Driver.
H > Used to install and uninstall the SFIT Absolute S & A Ti-Base in case of internal slip.
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and
the dedicated Stargrip Abutment Screw. > KSFR3812S & KSFR3819L for the SFIT Absolute S & A Ti-Base with Ø3.8 and
> Tightening torque force : 30 N.cm (50 N.cm Max.). KSFR4512S & KSFR4519L for the SFIT Absolute S & A Ti-Base with Ø4.5 and Ø5.5.

REGENERATIVE SOLUTION
COWELL®
168 SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base 169
COWELLMEDI HISTORY
SFIT Absolute Scanbody SFIT Absolute Digital Analog SFIT Absolute
Type Crown Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5
D
SFIT Absolute Diameter
Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5 Length Ø3.8 Ø4.5 Ø5.5
L
Diameter
H Height Ø4.25 Ø4.95 Ø5.85 3.6 2SSFLA3835 2SSFLA4535 2SSFLA5535
4.1 2SSFSB3835H 2SSFSB4535H 2SSFSB5535H
D > Packing unit: 1 SFIT Absolute Digital Analog.
> Packing unit: 1 SFIT Absolute Scanbody. > Replacement of the SFIT Absolute S or A Ti-Base shape in working cast.
> For both intra-oral scanning and model-scanning. > Used for both 3D printed model (RP) and stone model.
Crown > Made of 100% titanium alloy with a special coating applied. > Select according to dimension of the SFIT Absolute S or A Ti-Base.
> No need to spray.
> For the connection to the SFIT Absolute S Ti-Base, use the SFIT Absolute S Ti-Base Screw with the
1.2 Hex Ratchet Driver and Torque Wrench.
> For the connection to the SFIT Absolute A Ti-Base, use the SFIT Absolute A Ti-Base Screw with the

REID
Angulated Screw Ratchet Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.

SFIT Absolute Pick-up Impression Coping SFIT Titanium Cylinder


Type Crown Bridge

COWELL® IMPLANT SYSTEM


Type Crown Bridge SFIT Ti-Base
Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5
Diameter
SFIT Absolute Diameter
Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5 H Ø4.1 Ø4.8 Ø5.8 Ø4.1 Ø4.8 Ø5.8
L Height
Diameter
Length Ø3.95 Ø4.65 Ø5.65 Ø3.95 Ø4.65 Ø5.65 7 2SSFTC3835H 2SSFTC4535H 2SSFTC5535H 2SSFTC3835N 2SSFTC4535N 2SSFTC5535N
D
14.6 2SSFI3835C 2SSFI4535C 2SSFI5535C 2SSFI3835B 2SSFI4535B 2SSFI5535B
D > Packing unit: 1 SFIT Titanium Cylinder.
> Packing unit: 1 SFIT Absolute Pick-up Impression Coping + 1 Guide Pin. > Used over both SFIT S or A Ti-Base and SFIT Absolute S or A Ti-Base.
> For open tray impression. Crown Bridge > For provisional and permanent restorations.
Crown Bridge > Connected with the Guide Pin (2SSFIGP14). > Connected with the SFIT S or A Ti-Base Screw and SFIT Absolute S or A Ti-Base Screw.
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench. > Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm. > Tightening torque force: 30 N.cm.

COWELL® DIGITAL PRODUCTS


SFIT Absolute Transfer Post Type Crown Bridge SFIT Meta G UCLA Cylinder Type Crown Bridge
SFIT Ti-Base
Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5

COWELL® EXPERT INSTRUMENTS


SFIT Absolute Diameter
Ti-Base Diameter Ø3.8 Ø4.5 Ø5.5 Ø3.8 Ø4.5 Ø5.5
Diameter
L Diameter Height Ø4.3 Ø5 Ø5.7 Ø4.3 Ø5 Ø5.7
Length Ø4.3 Ø4.95 Ø5.9 Ø4.3 Ø4.95 Ø5.9 H
11.4 2SSFC3835C 2SSFC4535C 2SSFC5535C 2SSFC3835B 2SSFC4535B 2SSFC5535B
6 2SSFT3835LH 2SSFT4535LH 2SSFT5535LH 2SSFT3835LN 2SSFT4535LN 2SSFT5535LN
D

> Packing unit: 1 SFIT Absolute Transfer Post + 1 Guide Pin. D > Packing unit: 1 1 SFIT Meta G UCLA Cylinder.
> For closed tray impression. > Used over both SFIT S or A Ti-Base and SFIT Absolute S or A Ti-Base.
Crown Bridge > Also used as a scanbody for intra-oral scanning and model-scanning. > Modifiable to various types of abutments.
> Connected with the Guide Pin (2SSFT01SL). Crown Bridge > CCM alloy core for precise connection.
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench. > Cast with non-precious metal or gold alloy.
> Tightening torque force: 12~15 N.cm. > Connected with the SFIT S or A Ti-Base Screw and SFIT Absolute S or A Ti-Base Screw.
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.

REGENERATIVE SOLUTION
COWELL®
170 SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base SFIT Ti-Base System : Sub. SFIT Absolute Ti-Base 171
COWELLMEDI HISTORY
Component selection guide for Intra-oral scanning Component selection guide for Model-scanning
procedure procedure
the Sub. Multi SFIT Ti-Base System the Sub. Multi SFIT Ti-Base System
SUB. SUB.
HEXAGON HEXAGON
SYSTEM SYSTEM

REID
Crown

Crown
Multi Polishing Protector

COWELL® IMPLANT SYSTEM


Multi Polishing Protector

(Hex) (N-Hex) (Hex) (N-Hex)


Multi SFIT Ti-Base
Multi SFIT S Ti-Base Multi SFIT A Ti-Base Setting Screw

(Hex) (N-Hex) (Hex) (N-Hex)


Multi SFIT Ti-Base
Multi SFIT S Ti-Base Multi SFIT A Ti-Base Setting Screw

(Hex) (N-Hex)

Multi Scanbody

COWELL® DIGITAL PRODUCTS


Multi Digital Analog

Multi Digital Analog

(Hex) (N-Hex)

Multi Scanbody

(Hex) (N-Hex) (Hex) (N-Hex)

COWELL® EXPERT INSTRUMENTS


Multi Pick-up
Impression Coping Multi Transfer Post

(Hex) (N-Hex)

Multi S Abutment Multi A Abutment Multi Protection Cap

(Hex) (N-Hex)

Multi S Abutment Multi A Abutment Multi Protection Cap

REGENERATIVE SOLUTION
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short

COWELL®
Healing
Fixture Fixture Cover Screw Abutment
Submerged Short

172 SFIT Ti-Base System : Sub. Multi SFIT Ti-Base SFIT Ti-Base System : Sub. Multi SFIT Ti-Base 173
COWELLMEDI HISTORY
Multi S Abutment Diameter Ø4.5 Ø5.5 Abutment Screw Length
Length 2 2 Diameter
7.5 6.5
D Cuff 1.2 Hex.
2SMS451 2SMS551 2.15 2SSHR300 2SSHR400
L 1
D
C 2 2SMS452 2SMS552 > Packing unit: 1 Abutment Screw.
1 Piece 3 2SMS453 2SMS553 > To connect the Multi A Abutment.
L
> Tightened with the 1.2 Hex Driver and Torque Wrench.
4 2SMS454 2SMS554
5 2SMS455 2SMS555

> Packing unit: 1 Multi S Abutment.


> For Screw-Retained Prosthesis.
> Titanium base for the Multi SFIT S or A Ti-Base.

REID
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Integrated with the screw and abutment (solid screw).
> Use the S Holder for more stable position.
> Tightened with the S Machine or S Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
> Use the Multi Scanbody for digital flow.
> Abutment level impression.

COWELL® IMPLANT SYSTEM


Multi S & A
Multi Protection Cap Abutment Diameter Ø4.5 Ø5.5
Diameter
D Height Ø5.2 Ø6.2
5 2SMPC45 2SMPC55
Multi A Abutment Type Hex H
Diameter(Angle) Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°)
> Packing unit : 1 Multi Protection Cap.
D
L
1.2 Hex. > Protection from cheek and tongue for gingival healing period.
Length 2 2 2 2
A Cuff > Gingival retraction for prosthodontic margin of abutment.
C 2 2SMAH45152 > Alternative usage for sub-structure of temporary prosthesis.
3 2SMAH45153 2SMAH45303 2SMAH55153 2SMAH55303
4 2SMAH45154 2SMAH45304 2SMAH55154 2SMAH55304
5 2SMAH55155 2SMAH55305
2 Pieces

COWELL® DIGITAL PRODUCTS


Hex N-Hex
Type N-Hex
Diameter(Angle) Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°)
Length
Cuff 2 2 2 2
2 2SMAN45152
3 2SMAN45153 2SMAN45303 2SMAN55153 2SMAN55303
4 2SMAN45154 2SMAN45304 2SMAN55154 2SMAN55304
5 2SMAN55155 2SMAN55305

> Packing unit: 1 Multi A Abutment + 1 Abutment Screw. Multi Scanbody


> For Screw-Retained Prosthesis. 1.2 Hex.
Type Hex N-Hex

COWELL® EXPERT INSTRUMENTS


> Titanium base for the Multi SFIT S or A Ti-Base. Diameter
> Gold color for more translucent restoration. Height Ø4.5 Ø4.5
2.25
> Library available for EXOCAD®, 3Shape® & others. H 9 2SMB001H 2SMB001N
> Use the A Holder for more stable position.
> Connected with the Abutment Screw (2SSHR300 : ★ / 2SSHR400 : ●). > Packing unit: 1 Multi Scanbody + 1 Cylinder Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench. > For both intra-oral scanning and model-scanning.
D
> Tightening torque force: 30 N.cm. > Made of 100% titanium alloy with a special coating applied.
> Use the Multi Scanbody for digital flow. > No need to spray.
> Abutment level impression. > Connected with the Cylinder Screw (2SMC100).
Hex N-Hex
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.

REGENERATIVE SOLUTION
COWELL®
174 SFIT Ti-Base System : Sub. Multi SFIT Ti-Base SFIT Ti-Base System : Sub. Multi SFIT Ti-Base 175
COWELLMEDI HISTORY
Multi Pick-up Impression Coping Multi SFIT S Ti-Base
D 1.2 Hex Type Hex N-Hex
Type Hex N-Hex 22..3
2.3
.3 Multi S & A
Abutment Diameter Ø4.5 Ø4.5 Ø5.5 Ø4.5 Ø4.5 Ø5.5
Multi S & A 2.3
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5 Length
L 3.5 3.5 3.5 3.5 3.5 3.5
Diameter
L Length Ø4.65 Ø5.65 Ø4.65 Ø5.65 Diameter
C Cuff Ø5 Ø5.3 Ø5.7 Ø5 Ø5.3 Ø5.7
9 2SMIH45 2SMIH55 2SMIN45 2SMIN55 D 0.5 2SMSFT45H 2SMSFT55H 2SMSFT45N 2SMSFT55N
Ø5 Ø5.3 Ø5.7
> Packing unit: 1 Multi Pick-up Impression Coping + 1 Guide Pin (2SMGP012). 1.5 2SMSFT40H 2SMSFT40N
> For open tray impression.
> Connected with the Guide Pin. > Packing unit: 1 Multi SFIT S Ti-Base + 1 Multi SFIT S Ti-Base Screw.
> Tightened with the 1.2 Hex Driver and Torque Wrench. Hex > Used over both Multi S or A Abutment.
Hex N-Hex > For Screw Retained prosthesis.
> Tightening torque force: 12~15 N.cm.

REID
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Connected with the Multi SFIT S Ti-Base Screw.
L > Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
C > Tightening torque force: 30 N.cm.
D
> Abutment level impression.
Ø5 Ø5.3 Ø5.7

COWELL® IMPLANT SYSTEM


N-Hex

Multi Transfer Post


Type Hex N-Hex
D
Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
Diameter
L Length Ø4.5 Ø5.5 Ø4.5 Ø5.5
7.5 2SMTH45 2SMTH55 2SMTN45 2SMTN55

> Packing unit: 1 Multi Transfer Post + 1 Guide Pin (2SMTHS100). Multi SFIT A Ti-Base
> For closed tray impression. Type Hex N-Hex

COWELL® DIGITAL PRODUCTS


1.8 Stargrip
Hex N-Hex > Connected with the Guide Pin. Multi S & A
Abutment Diameter Ø4.5 Ø4.5 Ø5.5 Ø4.5 Ø4.5 Ø5.5
> Tightened with the 1.2 Hex Driver and Torque Wrench. 2.3
> Tightening torque force: 12~15 N.cm. L Length 3.5 3.5 3.5 3.5 3.5 3.5
Diameter
C Cuff Ø5 Ø5.3 Ø5.7 Ø5 Ø5.3 Ø5.7
D 0.5 2SMSFT45HA 2SMSFT55HA 2SMSFT45NA 2SMSFT55NA
Ø5 Ø5.3 Ø5.7
1.5 2SMSFT40HA 2SMSFT40NA

> Packing unit: 1 Multi SFIT A Ti-Base + 1 Multi SFIT A Ti-Base Screw.
Hex > Used over both Multi S or A Abutment.
> For Screw Retained prosthesis.
> Gold color for more translucent restoration.
Multi Digital Analog > Library available for EXOCAD®, 3Shape® & others.

COWELL® EXPERT INSTRUMENTS


Multi S & A
Ø4.5 Ø5.5 > Connected with the Multi SFIT A Ti-Base Screw.
Abutment Diameter L
D
Diameter
> Tightened with the Angulated Screw Ratchet Driver and Torque Wrench.
L Length Ø4.5 Ø5.5 C > Tightening torque force: 30 N.cm.
2 2SMLA45 2SMLA55 D
> Abutment level impression.
Ø5 Ø5.3 Ø5.7 * Angulated Screw Ratchet Driver
> Packing unit: 1 Multi Digital Analog.
Angulated Screw Type Ratchet
> Replacement of the Multi S or A Abutment shape in working cast. Ratchet Driver
Height
> Used for both 3D printed model (RP) and stone model. 24(Short) KRBUD15
N-Hex
> Select according to dimension of the Multi S or A Abutment. 29(Long) KRBUD20
H
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and
the dedicated Stargrip Abutment Screw.
> Tightening torque force : 30 N.cm (50 N.cm Max.).

REGENERATIVE SOLUTION
COWELL®
176 SFIT Ti-Base System : Sub. Multi SFIT Ti-Base SFIT Ti-Base System : Sub. Multi SFIT Ti-Base 177
COWELLMEDI HISTORY
Multi SFIT S Ti-Base Screw Height
Diameter
Ø2.3 Multi Holder
1.2 Hex 5.5 2SMCS100SF
H
2..3
22.3
.3
2.3
> Packing unit: 1 Multi SFIT S Ti-Base Screw. Type
> To connect the Multi SFIT S Ti-Base. Height Hand
H
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench. 20 KMHS01
S Holder
> Packing unit: 1 Multi S Holder.
> To position the Multi S Abutment more stably.

REID
H
Type
Height Hand
20 KMHA01
Diameter
Multi SFIT A Ti-Base Screw Height Ø2.3
A Holder > Packing unit: 1 Multi A Holder.
1.8 Stargrip 5.5 2SMCS100AF > To position the Multi A Abutment more stably.
1.2 Hex Driver
2.3
> Packing unit: 1 Multi SFIT A Ti-Base Screw.
> To connect the Multi SFIT A Ti-Base.

COWELL® IMPLANT SYSTEM


H
> Tightened with the Angulated Screw Ratchet Driver and Torque Wrench.

COWELL® DIGITAL PRODUCTS


Diameter
Multi SFIT Ti-Base Setting Screw Height Ø2.0
1.2 Hex
4.3 2SMCSS100

2 > Packing unit: 5 Multi SFIT Ti-Base Setting Screws.


> Used to screw the Multi SFIT S or A Ti-Base into the Multi Digital Analog or the Multi S & A Abutment when revising Multi S Machine Driver
H such prosthetic adaptions as shape, contact surface, occlusion and margin without giving a force to the head Type
Height Machine
of the Multi SFIT S or A Ti-Base to spread and fit in the inner space of prosthesis. H 27.5 KMMSD21L
> Tightened with the 1.2 Hex Ratchet Driver.
> Packing unit: 1 Multi S Machine Driver.
> To install the Multi S Abutment by machine.

COWELL® EXPERT INSTRUMENTS


Multi Polishing Protector Multi S Ratchet Driver
Type Hex Type
D Multi S & A Height Ratchet
Ø4.5 Ø5.5 H
Abutment Diameter
L Diameter
22 KRMSD15L
Length Ø4.5 Ø5.5
2 2SMPP45 2SMPP55 > Packing unit: 1 Multi S Ratchet Driver.
> To install the Multi S Abutment by hand.
> Packing unit: 1 Multi Polishing Protector.
> To polish work during lab procedure.

REGENERATIVE SOLUTION
COWELL®
178 SFIT Ti-Base System : Sub. Multi SFIT Ti-Base SFIT Ti-Base System : Sub. Multi SFIT Ti-Base 179
COWELLMEDI HISTORY
Component selection guide for • Intra-oral scanning
the Int. SFIT Ti-Base System • Model-scanning
SFIT S Ti-Base
1.2 Hex

3.5
Type Octa N-Octa
L
INT. Platform Ø4.8 Ø4.8 Ø5.9 Ø4.8 Ø4.8 Ø5.9
[Fixture Dia.] [Ø3.5 / Ø4.0 / Ø4.5] [Ø3.5 / Ø4.0 / Ø4.5] [Ø5.0 / Ø6.0] [Ø3.5 / Ø4.0 / Ø4.5] [Ø3.5 / Ø4.0 / Ø4.5] [Ø5.0 / Ø6.0]
OCTAGON C
SYSTEM Diameter Ø3.5 Ø5 Ø6.2 Ø3.5 Ø5 Ø6.2
D Length
Cuff 3.6 3.6 3.6 3.6 3.6 3.6
Ø3.5 Ø5 Ø6.2
0 ISFO35035 ISFN35035
1 ISFO50135 ISFO60135 ISFN50135 ISFN60135

REID
Crown Octa 2 ISFO50235 ISFO60235 ISFN50235 ISFN60235
3 ISFO50335 ISFO60335 ISFN50335 ISFN60335

L > Packing unit: 1 SFIT S Ti-Base + 1 SFIT S Ti-Base Screw.


C > For Screw Retained Prosthesis with straight screw channel.
> Gold color for more translucent restoration.
D > Library available for EXOCAD®, 3Shape® & others.
(Octa) (N-Octa) (Octa) (N-Octa) > Connected with the SFIT S Ti-Base Screw.
Ø3.5 Ø5 Ø6.2
SFIT S Ti-Base SFIT A Ti-Base SFIT Ti-Base > Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.

COWELL® IMPLANT SYSTEM


Setting Screw > Tightening torque force: 30 N.cm.
> Use the SFIT Scanbody for digital workflow.
N-Octa > Fixture level impression.

Scanbody

1.8 Stargrip
SFIT A Ti-Base
3.5

COWELL® DIGITAL PRODUCTS


Type Octa N-Octa
L
Platform Ø4.8 Ø4.8 Ø5.9 Ø4.8 Ø4.8 Ø5.9
C [Fixture Dia.] [Ø3.5 / Ø4.0 / Ø4.5] [Ø3.5 / Ø4.0 / Ø4.5] [Ø5.0 / Ø6.0] [Ø3.5 / Ø4.0 / Ø4.5] [Ø3.5 / Ø4.0 / Ø4.5] [Ø5.0 / Ø6.0]
Digital Analog Digital Analog Diameter Ø3.5 Ø5 Ø6.2 Ø3.5 Ø5 Ø6.2
D Length
Cuff 3.6 3.6 3.6 3.6 3.6 3.6
Ø3.5 Ø5 Ø6.2
0 ISFO35035A ISFN35035A
1 ISFO50135A ISFO60135A ISFN50135A ISFN60135A
Octa 2 ISFO50235A ISFO60235A ISFN50235A ISFN60235A
3 ISFO50335A ISFO60335A ISFN50335A ISFN60335A
L
> Packing unit: 1 SFIT A Ti-Base + 1 SFIT A Ti-Base Screw.

COWELL® EXPERT INSTRUMENTS


C
(Octa) (Octa) (N-Octa) > For Screw Retained Prosthesis with angulated screw channel.
Scanbody Pick-up Impression Coping Transfer Post > Gold color for more translucent restoration.
D > Library available for EXOCAD®, 3Shape® & others.
Ø3.5 Ø5 Ø6.2 > Connected with the SFIT A Ti-Base Screw.
Intra-oral Model > Tightened with the Angulated Screw Ratchet Driver and Torque Wrench.
Scanning Scanning Angulated Screw > Tightening torque force: 30 N.cm.
Ratchet Driver
N-Octa > Use the SFIT Scanbody for digital workflow.
> Fixture level impression.

* Angulated Screw Ratchet Driver


Type Ratchet
Height
24(Short) KRBUD15
29(Long) KRBUD20
H
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and

REGENERATIVE SOLUTION
the dedicated Stargrip Abutment Screw.
> Tightening torque force : 30 N.cm (50 N.cm Max.).
Healing
Fixture Cover Screw Headless Screw Abutment

COWELL®
180 SFIT Ti-Base System : Int. SFIT Ti-Base SFIT Ti-Base System : Int. SFIT Ti-Base 181
COWELLMEDI HISTORY
SFIT S Ti-Base Screw Transfer Post
SFIT S Ti-Base Cuff 0 1 2 3 D
1.2 Hex Height
Diameter 9 10.6 11.6 12.6
Ø2.3 ISFS00S ISFS10S ISFS20S ISFS30S Type Octa N-Octa
D
Platform
> Packing unit: 1 SFIT S Ti-Base Screw. L [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
2 Pieces 1 Piece Fixture Dia.
H > Used to connect the SFIT S Ti-Base. Length Ø4.8 Ø5.9 Ø4.8 Ø5.9
ISFS00S: SFIT S Ti-Base with Cuff 0, ISFS10S: SFIT S Ti-Base with Cuff 1,
11.5 ITOR400 ITOW500 ITNR400 ITNW500
ISFS20S: SFIT S Ti-Base with Cuff 2, ISFS30S: SFIT S Ti-Base with Cuff 3.
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench. > Packing unit: Octa - 1 Transfer Post + 1 Guide Pin (Regular: ITOR400S / Wide: ITOW500S)
N-Octa - 1 Transfer Post (solid screw).
> For closed tray impression.
Octa N-Octa > Connected with the Guide Pin.

REID
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.
SFIT A Ti-Base Screw
SFIT S Ti-Base Cuff 0 1 2 3
1.8 Stargrip Height
Diameter 9 10.6 11.6 12.6
Ø2.3 ISFS00A ISFS10A ISFS20A ISFS30A
D

> Packing unit: 1 SFIT A Ti-Base Screw.


H > Used to connect the SFIT A Ti-Base.
ISFS00A: SFIT A Ti-Base with Cuff 0, ISFS10A: SFIT A Ti-Base with Cuff 1,

COWELL® IMPLANT SYSTEM


ISFS20A: SFIT A Ti-Base with Cuff 2, ISFS30A: SFIT A Ti-Base with Cuff 3.
Digital Analog
> Tightened with the Angulated Screw Ratchet Driver and Torque Wrench. Platform
[Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
D
Diameter
Height Ø4.8 Ø5.9
13.5 IDR001R IDR001W
H
> Packing unit: 1 Digital Analog.
> Analog of fixture for working cast.
Scanbody 1.2 Hex.
> Used for both 3D printed model (RP) and stone model.
Type Octa > Select according to fixture platform.
D Platform
[Fixture Dia.] Ø4.8 & Ø5.9 [Ø3.5 / Ø4.0 / Ø4.5, Ø5.0 / Ø6.0]
2.3
Diameter
Length Ø4.5
L
6

COWELL® DIGITAL PRODUCTS


ISB406
10 ISB410

> Packing unit: 1 Scanbody + 1 Abutment Screw (ISHR110).


> For both intra-oral scanning and model-scanning.
> Made of 100% titanium alloy with a special coating applied.
Octa > No need to spray.
> Connected with the Abutment Screw (ISHR110).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.

Diameter
SFIT Ti-Base Setting Screw Height Ø1.95
1.2 Hex 7.5 ISFSS100

COWELL® EXPERT INSTRUMENTS


Pick-up Impression Coping
D 1.95 > Packing unit: 5 SFIT Ti-Base Setting Screws.
Type Octa > Used to screw the SFIT S or A Ti-Base into the Digital Analog or the Fixture when revising such prosthetic
Platform
Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] adaptions as shape, contact surface, occlusion and margin without giving a force to the head of
[Fixture Dia.]
Diameter H the SFIT Ti-Base S or A Ti-Base to spread and fit in the inner space of the prosthesis.
L Length Ø5.5 Ø6.6 > Tightened with the 1.2 Hex Ratchet Driver.
2 Pieces
10 IIOR001 IIOW001

> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (IIOR001S).


> For open tray impression.
> Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Octa > Tightening torque force: 12~15 N.cm.

REGENERATIVE SOLUTION
COWELL®
182 SFIT Ti-Base System : Int. SFIT Ti-Base SFIT Ti-Base System : Int. SFIT Ti-Base 183
COWELLMEDI HISTORY
Component selection guide for • Intra-oral scanning
• Model-scanning
the Sub. Hybrid Ti-Base System
Hybrid S Ti-Base
D
SUB. Type Hex N-Hex
HEXAGON L
1.2 Hex.

SYSTEM Diameter Ø4.0 Ø5.0 Ø6.0 Ø4.0


C 2.15 Length
Cuff 3.75 3.75 3.75 3.75
0.8 2SLH404 2SLH504 2SLH604 2SLN404
Ø4.0 Ø5.0 Ø6.0 2 2SLH424 2SLH524 2SLH624 2SLN424

REID
Crown 3 2SLH434 2SLH534 2SLH634 2SLN434
Hex > Packing unit : 1 Hybrid S Ti-Base + 1 Abutment Screw.
> For Screw-Cement or Cement Retained Abutment.
D
> Titanium base for strength of CAD/CAM customized abutment or crown.
> Gold color for more translucent restoration.
L
> Lingual surface hole for more esthetic restoration (Ø4.0).
> Right angled (Ø4.0) and humped design (Ø5.0, Ø6.0) for anti-rotation of prosthesis.
C > Library available for EXOCAD®, 3Shape® & Others.
(Hex) (N-Hex) (Hex) (N-Hex) (Hex) (Hex) (N-Hex) > Connected with the Abutment Screw (2SSHR200).

COWELL® IMPLANT SYSTEM


Hybrid S Ti-Base Hybrid L Ti-Base Hybrid A Ti-Base Hybrid Ti-Block > Tightened with the 1.2 Hex Driver and Torque Wrench.
Ø4.0 > Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work.
> Fixture level impression.
N-Hex

Digital Analog Digital Analog

Hybrid L Ti-Base

COWELL® DIGITAL PRODUCTS


D
Type Hex N-Hex
L 1.2 Hex.
Diameter Ø4.0 Ø5.0 Ø6.0 Ø4.0
C 2.15 Length
Cuff 5.5 5.5 5.5 5.5
1 2SLH415 2SLH515 2SLH615 2SLN415
Ø4.0 Ø5.0 Ø6.0
(Short) (Long) (X-Long) (Hex) (N-Hex) (Hex) (N-Hex) 2 2SLH425 2SLH525 2SLH625 2SLN425
Bite Impression Coping Pick-up Impression Coping Transfer Post 3 2SLH435 2SLH535 2SLH635 2SLN435
Hex
> Packing unit : 1 Hybrid L Ti-Base + 1 Abutment Screw.
(Hex)
> For Screw-Cement or Cement Retained Abutment.
Scanbody D > Titanium base for strength of CAD/CAM customized abutment or crown.

COWELL® EXPERT INSTRUMENTS


> Gold color for more translucent restoration.
L > Cutting surface (Ø4.0) and humped design (Ø5.0, Ø6.0) for anti-rotation of prosthesis.
> Library available for EXOCAD®, 3Shape® & Others.
C > Connected with the Abutment Screw (2SSHR200).
Intra-oral Model > Tightened with the 1.2 Hex Driver and Torque Wrench.
Scanning Scanning
Ø4.0
> Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work.
> Fixture level impression.
N-Hex

Healing
Fixture Fixture Cover Screw Abutment
Submerged Short

REGENERATIVE SOLUTION
COWELL®
184 InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base 185
COWELLMEDI HISTORY
Hybrid A Ti-Base Bite Impression Coping
Max 25° Type Hex
D Type Hex(Short) Hex(Long) Hex(X-Long)
Ø1.8 Diameter Ø4.0
L Diameter Ø4.5 Ø4.5 Ø4.5
2.15 Length L
Cuff 3.75 Cuff
C Length 2 4 6
0.8 2SLH404A C 4.0 2SBIC45S 2SBIC45L 2SBIC45X
2 2SLH424A
D
3 2SLH434A > Packing unit : 1 Bite Impression Coping (Inbuilt Guide Pin).
> Designed to simultaneously take bite and impression.
> Packing unit : 1 Hybrid A Ti-Base + 1 Abutment Screw. > For Closed Tray Impression (Bite Impression).
Hex > For Screw-Cement or Cement Retained Abutment. (Short) (Long) (X-Long) > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Titanium base for strength of CAD/CAM customized abutment or crown.
> For Fabrication of Angulated Screw Channel up to 25°.

REID
> Library available for EXOCAD®, 3Shape® & Others.
Hex
> Connected with the Stargrip Abutment Screw (2SLAH100, 2SLAH200 & 2SLAH300).
> Tightened with the Angulated Screw Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work.
> Fixture level impression.

* Angulated Screw Ratchet Driver


Type Ratchet
Height

COWELL® IMPLANT SYSTEM


24(Short) KRBUD15
29(Long) KRBUD20
H
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and
the dedicated Stargrip Abutment Screw.
> Tightening torque force : 30 N.cm (50 N.cm Max.).

Hybrid Ti-Block Pick-up Impression Coping


Type Hex N-Hex
D D
1.2 Hex. Diameter D Type Hex N-Hex
Length 10 12 14 10 12 14
Diameter
20 CSHH10S CSHH12S CSHH14S CSHN10S CSHN12S CSHN14S Length / Cuff Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5

COWELL® DIGITAL PRODUCTS


2.45
14 (Short) / 4 2SIH454S 2SIH554S 2SIH654S 2SIN454S 2SIN554S 2SIN654S
L L > Packing unit : 1 Hybrid Ti-Block + 2 Abutment Screws. L
> For Screw-Cement or Cement Retained Abutment. 14 (Short) / 2 2SIH45S 2SIH55S 2SIH65S 2SIN45S 2SIN55S 2SIN65S
> Block abutment for CAD/CAM customized abutment. 16 (Long) / 4 2SIH45L 2SIH55L 2SIH65L 2SIN45L 2SIN55L 2SIN65L
> Library available for EXOCAD®, 3Shape® & Others. C

Hex N-Hex > Connected with the Abutment Screw (2SSHR100). > Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (2SISR001SS / 2SISR001SL).
> Tightened with the 1.2 Hex Driver and Torque Wrench. > For open tray impression.
(Short) (Short) (Long) (Short) (Short) (Long)
> Tightening torque force : 30 N.cm. > Connected with the Guide Pin.
> Use the Scanbody for 3D Work. > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Fixture level impression.
Hex N-Hex 2 Pieces

COWELL® EXPERT INSTRUMENTS


Scanbody
D Diameter Ø4.3
1.2 Hex. Length
Cuff 8
L 2.45 2 2SSB4329
> Packing unit : 1 Scanbody + 1 Abutment Screw.
C > For both, model scanner and intra oral scanner.
> For Hybrid S & L Ti-Base and Hybrid A Ti-Block.
> Made of 100% titanium alloy with a special coating applied.
> No need to spray.
> Connected with the Abutment Screw (2SSHR100).
> Tightened with the 1.2 Hex Driver and Torque Wrench.

REGENERATIVE SOLUTION
> Tightening torque force : 15~20 N.cm.

COWELL®
186 InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base 187
COWELLMEDI HISTORY
Transfer Post Abutment Screw
D
Type Hex N-Hex
Diameter 1.2 Hex. 1.2 Hex. Diameter
Length / Cuff Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5 Height 2.45 2.15
L
9 (Short) / 2 2STH45S 2STH55S 2STH65S 2STN45S 2STN55S 2STN65S D D 8.5 2SSHR100 2SSHR200
11 (Long) / 4 2STH45L 2STH55L 2STH65L 2STN45L 2STN55L 2STN65L > Packing unit : 1 Abutment Screw.
C H > 2SSHR100 : Hybrid Block / Scanbody.
> Packing unit : 1 Transfer Post + 1 Guide Pin (Hex) / 1 Transfer Post (N-Hex, Solid Type). > 2SSHR200 : Hybrid S & L Ti-Base.
> For closed tray impression. > Tightened with the 1.2 Hex Driver and Torque Wrench.
(Short) (Long) (Short) (Long) > Connected with the Guide Pin (2STH001SS / 2STH001SL). 2SSHR100 2SSHR200
> Tightened with the 1.2 Hex Driver and Torque Wrench.
2 Pieces 1 Piece

REID
Hex N-Hex

COWELL® IMPLANT SYSTEM


Digital Analog Stargrip Abutment Screw
D Diameter
Height Ø3.9 Ø1.8 Height 2 3.2 4.2
Diameter
12 2SDR001 D
2.15 2SLAH100 2SLAH200 2SLAH300
H
> Packing unit: 1 Digital Analog. H > Packing unit : 1 Abutment Screw.
> Analog of fixture for working cast. > Exclusive for Hybrid A Ti-Base (2SLAH100 for 2SLH404A, 2SLAH200 for 2SLH424A & 2SLAH300 for 2SLH434A).

COWELL® DIGITAL PRODUCTS


> Used for both 3D printed model (RP) and stone model. > Tightened with the Angulated Driver and Torque Wrench.

COWELL® EXPERT INSTRUMENTS


REGENERATIVE SOLUTION
COWELL®
188 InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Hybrid Ti-Base 189
COWELLMEDI HISTORY
Component selection guide for • Intra-oral scanning
Multi S Abutment Diameter

Cuff
Length
Ø4.5
2
Ø5.5
2
• Model-scanning D

the Sub. Multi Hybrid Ti-Base System L 1 2SMS451 2SMS551

C 2 2SMS452 2SMS552
1 Piece 3 2SMS453 2SMS553
SUB. 4 2SMS454 2SMS554
HEXAGON
SYSTEM 5 2SMS455 2SMS555
Crown > Packing unit: 1 Multi S Abutment.
> For Screw-Retained Prosthesis.
> Titanium base for the Multi Hybrid Ti-Base.
> Gold color for more translucent restoration.

REID
> Library available for EXOCAD®, 3Shape® & others.
Multi Polishing Protector
> Integrated with the screw and abutment (solid screw).
> Use the S Holder for more stable position.
> Tightened with the S Machine or S Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
> Use the Multi Scanbody for digital flow.
> Abutment level impression.

(Hex) (N-Hex)

COWELL® IMPLANT SYSTEM


Multi Hybrid Ti-Base
Multi A Abutment Type Hex
Diameter(Angle) Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°)
D 1.2 Hex.
L Length
A Cuff 2 2 2 2
C 2 2SMAH45152
3 2SMAH45153 2SMAH45303 2SMAH55153 2SMAH55303
(Hex) (N-Hex)
4 2SMAH45154 2SMAH45304 2SMAH55154 2SMAH55304
Multi Scanbody
5 2SMAH55155 2SMAH55305
Hex N-Hex 2 Pieces
Type N-Hex
Diameter(Angle) Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°)

COWELL® DIGITAL PRODUCTS


Length
Cuff 2 2 2 2

Multi Digital Analog Multi Digital Analog 2 2SMAN45152


3 2SMAN45153 2SMAN45303 2SMAN55153 2SMAN55303
4 2SMAN45154 2SMAN45304 2SMAN55154 2SMAN55304
5 2SMAN55155 2SMAN55305

> Packing unit: 1 Multi A Abutment + 1 Abutment Screw.


> For Screw-Retained Prosthesis.
(Hex) (N-Hex) (Hex) (N-Hex)
(Hex) (N-Hex) > Titanium base for the Multi Hybrid Ti-Base.
Multi Scanbody Multi Pick-up Impression Coping Multi Transfer Post > Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & others.
> Use the A Holder for more stable position.

COWELL® EXPERT INSTRUMENTS


Intra-oral Model > Connected with the Abutment Screw (2SSHR300 : ★ / 2SSHR400 : ●).
Scanning Scanning > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
> Use the Multi Scanbody for digital flow.
> Abutment level impression.

Abutment Screw
(Hex) (N-Hex)
Height
Multi S Abutment Multi A Abutment Multi Protection Cap 1.2 Hex. Diameter 7.5 6.5
2.15 2SSHR300 2SSHR400
D
> Packing unit: 1 Abutment Screw.
> To connect the Multi A Abutment.
H
> Tightened with the 1.2 Hex Driver and Torque Wrench.

REGENERATIVE SOLUTION
Healing
Fixture Fixture Cover Screw

COWELL®
Abutment
Submerged Short

190 InnoFit® Hybrid Ti-Base System : Sub. Multi Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Multi Hybrid Ti-Base 191
COWELLMEDI HISTORY
Multi Protection Cap Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Multi Transfer Post
Diameter
Type Hex N-Hex
D Height Ø5.2 Ø6.2 D
Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5
5 2SMPC45 2SMPC55
Diameter
H L Length Ø4.5 Ø5.5 Ø4.5 Ø5.5
> Packing unit : 1 Multi Protection Cap.
7.5 2SMTH45 2SMTH55 2SMTN45 2SMTN55
> Protection from cheek and tongue for gingival healing period.
> Gingival retraction for prosthodontic margin of abutment.
> Alternative usage for sub-structure of temporary prosthesis. > Packing unit: 1 Multi Transfer Post + 1 Guide Pin (2SMTHS100).
> For closed tray impression.
Hex N-Hex > Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.

REID
Multi Digital Analog
Multi S & A
Abutment Diameter Ø4.5 Ø5.5

COWELL® IMPLANT SYSTEM


D
Multi Scanbody 1.2 Hex. L
Diameter
Length Ø4.5 Ø5.5
Type Hex N-Hex
2 2SMLA45 2SMLA55
Diameter
Height Ø4.5 Ø4.5
2.25
H 9 2SMB001H 2SMB001N > Packing unit: 1 Multi Digital Analog.
> Replacement of the Multi S or A Abutment shape in working cast.
> Packing unit : 1 Scanbody + 1 Cylinder Screw. > Used for both 3D printed model (RP) and stone model.
> For both, model scanner and intra oral scanner. > Select according to dimension of the Multi S or A Abutment.
D > For the Multi Hybrid Ti-Base.
> Made of 100% titanium alloy with a special coating applied.
> No need to spray.
Hex N-Hex > Connected with the Cylinder Screw (2SMCS100).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 15~20 N.cm.

COWELL® DIGITAL PRODUCTS


Multi Hybrid Ti-Base
1.2 Hex.
Type Hex N-Hex
Diameter
Cuff Ø4.5 Ø4.5 Ø5.5 Ø4.5 Ø4.5 Ø5.5
2.25
0.5 2SMHT45H 2SMHT55H 2SMHT45N 2SMHT55N
C 1.5 2SMHT40H 2SMHT40N
D
> Packing unit : 1 Multi Hybrid Ti-Base + 1 Cylinder Screw.
> For Screw-Cement or Cement Retained Abutment.
Hex N-Hex > Titanium base for strength of CAD/CAM customized abutment or crown.
Multi Pick-up Impression Coping
> Gold color for more translucent restoration.
D > Cutting surface for anti-rotation of prosthesis.
Type Hex N-Hex > Library available for EXOCAD®, 3Shape® & Others.

COWELL® EXPERT INSTRUMENTS


Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5 > Connected with the Cylinder Screw (2SMCS100).
Diameter > Tightened with the 1.2 Hex Driver and Torque Wrench.
L Length Ø4.65 Ø5.65 Ø4.65 Ø5.65 > Tightening torque force : 30 N.cm.
9 2SMIH45 2SMIH55 2SMIN45 2SMIN55 > Use the Scanbody for 3D Work.
> Abutment level impression.
> Packing unit: 1 Multi Pick-up Impression Coping + 1 Guide Pin (2SMGP012).
> For open tray impression.
> Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex N-Hex
> Tightening torque force: 12~15 N.cm.
Multi Cylinder Screw
Diameter
Height Ø2.25
1.2 Hex.
5 2SMCS100

REGENERATIVE SOLUTION
D > Packing unit : 1 Multi Cylinder Screw.
> Connected with the Multi Scanbody, Multi Hybrid Ti-Base.
H > Tightened with the 1.2 Hex Driver and Torque Wrench.

COWELL®
> Tightening torque force : 30 N.cm.

192 InnoFit® Hybrid Ti-Base System : Sub. Multi Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Multi Hybrid Ti-Base 193
COWELLMEDI HISTORY
Lock Abutment
Component selection guide for • Intra-oral scanning D
Diameter

Cuff
Length
Ø4.5
2.15
• Model-scanning
the Sub. Lock Hybrid Ti-Base System L
C
0.5 2SLA400
1 2SLA410
2 2SLA420
SUB. 3 2SLA430
HEXAGON
SYSTEM 4 2SLA440
Crown > Packing unit : 1 Lock Abutment.
> For Screw-Retained Prosthesis.
> Titanium base for Lock Hybrid Ti-Base.
> Gold color for more translucent restoration.

REID
> Integrated with screw and abutment.
> Tightened with the Lock Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.
Lock Hybrid Ti-Base

COWELL® IMPLANT SYSTEM


Lock Protection Cap Height
Diameter
Ø4.5
(N-Hex)
D
Lock Scanbody 4.3 2SLP45
H > Packing unit : 1 Lock Protection Cap.
> Protection from cheek and tongue for gingival healing period.
> Gingival retraction for prosthodontic margin of abutment.

Lock Digital Analog Lock Digital Analog

COWELL® DIGITAL PRODUCTS


(N-Hex)
Lock Scanbody Lock Pick-up Impression Coping

Intra-oral Model
Scanning Scanning

Lock Scanbody
Diameter
Ø4.5

COWELL® EXPERT INSTRUMENTS


Lock Protection Cap 1.2 Hex. Height
9 2SLB001H
H 2.3
> Packing unit : 1 Scanbody + 1 Cylinder Screw.
> For both, model scanner and intra oral scanner.
> For the Lock Hybrid Ti-Base.
D > Made of 100% titanium alloy with a special coating applied.
> No need to spray.
> Connected with the Cylinder Screw (2SLCS200).
Lock Abutment > Tightened with the 1.2 Hex Driver and Torque Wrench.
N-Hex > Tightening torque force : 15~20 N.cm.

REGENERATIVE SOLUTION
Healing
Fixture Fixture Cover Screw

COWELL®
Abutment
Submerged Short

194 InnoFit® Hybrid Ti-Base System : Sub. Lock Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Lock Hybrid Ti-Base 195
COWELLMEDI HISTORY
Lock Pick-up Impression Coping

Length
Diameter
Ø4.5 Lock Cylinder Screw
Diameter
16 2SLIH45 1.2 Hex. Height Ø2.3
L 4.8 2SLCS200
> Packing unit : 1 Lock Pick-up Impression Coping + 1 Guide Pin (2SLIH45S).
> For open tray impression. 2.3
> Packing unit : 1 Cylinder Screw.
H > Connected with the Lock Scanbody, Lock Hybrid Ti-Base.
D
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.

REID
COWELL® IMPLANT SYSTEM
Lock Digital Analog Lock Ratchet Driver
D Diameter
Length Ø3.5 H
L Type
2.2 2SLLA35 Height Ratchet
> Packing unit: 1 Lock Digital Analog. 14.2 KRLRD18
> Used for both 3D printed model (RP) and stone model.
H
28.5 KRLRD28
> Packing unit : 1 Lock Ratchet Driver.
> To install the Lock Abutment by hand.

COWELL® DIGITAL PRODUCTS


Lock Hybrid Ti-Base Cuff
Diameter
Ø4.5

COWELL® EXPERT INSTRUMENTS


1.2 Hex. 0.5 2SLHT40N

> Packing unit : 1 Lock Hybrid Ti-Base + 1 Cylinder Screw.


2.3 > For Screw-Cement or Cement Retained Abutment.
> Titanium base for strength of CAD/CAM customized abutment or crown.
C > Gold color for more translucent restoration.
> Cutting surface for anti-rotation of prosthesis.
D
> Library available for EXOCAD®, 3Shape® & Others.
> Connected with the Cylinder Screw (2SLCS200).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
N-Hex > Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work.
> Abutment level impression.

REGENERATIVE SOLUTION
COWELL®
196 InnoFit® Hybrid Ti-Base System : Sub. Lock Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub. Lock Hybrid Ti-Base 197
COWELLMEDI HISTORY
Hybrid S Ti-Base
Component selection guide for • Intra-oral scanning D
• Model-scanning
the Sub-N. Hybrid Ti-Base System L
1.2 Hex.
Type Hex
2.25 Diameter Ø4.0
C Length
Cuff 3.75
SUB-N.
HEXAGON 0.8 SLH404N
SYSTEM 2 SLH424N
3 SLH434N
Crown Hex
> Packing unit : 1 Hybrid S Ti-Base + 1 Abutment Screw. > Library available for EXOCAD®, 3Shape® & Others.
> For Screw-Cement or Cement Retained Abutment. > Connected with the Abutment Screw (SSHR100N).

REID
> Titanium base for strength of CAD/CAM customized > Tightened with the 1.2 Hex Driver and Torque Wrench.
abutment or crown. > Tightening torque force : 30 N.cm.
> Gold color for more translucent restoration. > Use the Scanbody for 3D Work.
> Lingual surface hole for more esthetic restoration. > Fixture level impression.
> Right angled for anti-rotation of prosthesis.
(Hex) (Hex) (Hex)
Hybrid S Ti-Base Hybrid L Ti-Base Hybrid A Ti-Base Hybrid L Ti-Base
D
1.2 Hex.

COWELL® IMPLANT SYSTEM


Type Hex
L Diameter Ø4.0
2.25
Length
C Cuff 5.5
1 SLH415N
2 SLH425N
3 SLH435N
Scanbody
Hex > Packing unit : 1 Hybrid L Ti-Base + 1 Abutment Screw. > Library available for EXOCAD®, 3Shape® & Others.
> For Screw-Cement or Cement Retained Abutment. > Connected with the Abutment Screw (SSHR100N).
> Titanium base for strength of CAD/CAM customized > Tightened with the 1.2 Hex Driver and Torque Wrench.
abutment or crown. > Tightening torque force : 30 N.cm.
> Gold color for more translucent restoration. > Use the Scanbody for 3D Work.
> Cutting surface for anti-rotation of prosthesis. > Fixture level impression.

COWELL® DIGITAL PRODUCTS


Digital Analog Digital Analog

Hybrid A Ti-Base
Max 25°

Ø1.8 Type Hex


L
2.25
Diameter Ø4.0
C Length
Cuff 3.75
0.8 SLH404AN
(Hex) (N-Hex) (Hex) (N-Hex)

COWELL® EXPERT INSTRUMENTS


Scanbody Pick-up Impression Coping Transfer Post D 2 SLH424AN
3 SLH434AN
Hex
Intra-oral Model > Packing unit : 1 Hybrid A Ti-Base + 1 Abutment Screw. > Library available for EXOCAD®, 3Shape® & Others.
Scanning Scanning
> For Screw-Cement or Cement Retained Abutment. > Connected with the Stargrip Abutment Screw
> Titanium base for strength of CAD/CAM customized (SLAH100N, SLAH200N & SLAH300N).
abutment or crown. > Tightened with the Angulated Screw Ratchet Driver
> For Fabrication of Angulated Screw Channel up to 25°. and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work.
> Fixture level impression.
* Angulated Screw Ratchet Driver
Type Ratchet
Height
24(Short) KRBUD15
Healing

REGENERATIVE SOLUTION
Fixture Cover Screw Abutment 29(Long) KRBUD20
H
> Stable to internal slip or fracture due to wide contact area of the Angulated Driver and
the dedicated Stargrip Abutment Screw.

COWELL®
> Tightening torque force : 30 N.cm (50 N.cm Max.).

198 InnoFit® Hybrid Ti-Base System : Sub-N. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub-N. Hybrid Ti-Base 199
COWELLMEDI HISTORY
Scanbody Digital Analog
D D Diameter
1.2 Hex. Ø3.9
Diameter Ø4.3 Height
Length 12 SDR001N
2.25 Cuff 8
L
2 SSB4329N H
> Packing unit: 1 Digital Analog.
C
L
> Packing unit : 1 Scanbody + 1 Abutment Screw. > Analog of fixture for working cast.
> For both, model scanner and intra oral scanner. > Used for both 3D printed model (RP) and stone model.
> For the Hybrid S and L Ti-Base.
> Made of 100% titanium alloy with a special coating applied.
> No need to spray.
> Connected with the Abutment Screw (SSHR100N).
> Tightened with the 1.2 Hex Driver and Torque Wrench.

REID
> Tightening torque force : 15~20 N.cm.

COWELL® IMPLANT SYSTEM


Pick-up Impression Coping Type Hex N-Hex Abutment Screw
D
Diameter 1.2 Hex.
Length / Cuff Ø4.5 Ø4.5
Height
14 (Short) / 2 SIH45SN SIN45SN D Length 2.25
L
2 Pieces 16 (Long) / 4 SIH45LN SIN45LN 10.2 SSHR100N

C
D > Packing unit : 1 Abutment Screw.
> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin. > Tightened with the 1.2 Hex Driver and Torque Wrench.
> For open tray impression. > Tightening torque force : 30 N.cm.
> Connected with the Guide Pin (SIS001SN / SIS001LN).
(Short) (Long) (Short) (Long)
> Tightened with the 1.2 Hex Driver and Torque Wrench.

Hex N-Hex

COWELL® DIGITAL PRODUCTS


Transfer Post Stargrip Abutment Screw
D

COWELL® EXPERT INSTRUMENTS


L Type Hex N-Hex Ø1.8
D Height 10.2 11.4 12.4
Diameter Diameter
Length / Cuff Ø4.5 Ø4.5
C 2.25 SLAH100N SLAH200N SLAH300N
9 (Short) / 2 STH45SN STN45SN H
STH45LN STN45LN
> Packing unit : 1 Stargrip Abutment Screw.
11 (Long) / 4
(Short) (Long) (Short) (Long)
> Exclusive for Hybrid A Ti-Base (SLAH100N for SLH404AN, SLAH200N for SLH424AN & SLAH300N for SLH434AN).
> Tightened with the Angulated Driver and Torque Wrench.
2 Pieces 1 Piece > Packing unit : 1 Transfer Post + 1 Guide Pin (Hex) / 1 Transfer Post (N-Hex, Solid).
> For closed tray impression.
> Connected with the Guide Pin (STS001SN / STS001LN).
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex N-Hex

REGENERATIVE SOLUTION
COWELL®
200 InnoFit® Hybrid Ti-Base System : Sub-N. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub-N. Hybrid Ti-Base 201
COWELLMEDI HISTORY
Component selection guide for • Intra-oral scanning
Multi S Abutment Diameter

Cuff
Length
Ø4.5
2
• Model-scanning
the Sub-N. Multi Hybrid Ti-Base System D

L
1 SMS451N
SMS452N
2
C
3 SMS453N
1 Piece
SUB-N. 4 SMS454N
HEXAGON
SYSTEM > Packing unit : 1 Multi S Abutment.
> For Screw-Retained Prosthesis.
Crown > Titanium base for the Multi Hybrid Ti-Base.
> Gold color for more translucent restoration.
> Integrated with screw and abutment.

REID
> Library available for EXOCAD®, 3Shape® & Others.
> Use the S Holder for more stable position.
Multi Polishing Protector > Tightened with the S Machine & S Ratchet Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.

(Hex) (N-Hex)

COWELL® IMPLANT SYSTEM


Multi Hybrid Ti-Base Multi A Abutment
Type Hex
1.2 Hex.
Diameter(Angle)
Cuff Ø4.5(15°) Ø4.5(30°)
D
L
A 1.95 2 SMAH45152BN

C 3 SMAH45153BN SMAH45303BN
(Hex) (N-Hex) 4 SMAH45154BN SMAH45304BN
Multi Scanbody

Type N-Hex
Diameter(Angle)
Hex N-Hex 2 Pieces Cuff Ø4.5(15°) Ø4.5(30°)
2 SMAN45152NB

COWELL® DIGITAL PRODUCTS


3 SMAN45153NB SMAN45303NB
Multi Digital Analog Multi Digital Analog 4 SMAN45154NB SMAN45304NB

> Packing unit : 1 Multi A Abutment + 1 Abutment Screw.


> For Screw-Retained Prosthesis.
> Titanium base for the Multi Hybrid Ti-Base.
> Gold color for more translucent restoration.
> Library available for EXOCAD®, 3Shape® & Others.
> Use the A Holder for more stable position.
(Hex) (N-Hex) (Hex) (N-Hex) > Connected with the Abutment Screw (SSHR200N : ★ / SSHR300N : ● ).
Multi Scanbody Multi Pick-up Impression Coping Multi Transfer Post > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Abutment level impression.

COWELL® EXPERT INSTRUMENTS


Intra-oral Model
Scanning Scanning

Abutment Screw
1.2 Hex. Height
Multi S Abutment Multi A Abutment Multi Protection Cap Diameter 8.7 9.3

D
1.95 SSHR200N SSHR300N
> Packing unit: 1 Abutment Screw.
H
> To connect the Multi A Abutment.
> Tightened with the 1.2 Hex Driver and Torque Wrench.

REGENERATIVE SOLUTION
Healing

COWELL®
Fixture Cover Screw Abutment

202 InnoFit® Hybrid Ti-Base System : Sub-N. Multi Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub-N. Multi Hybrid Ti-Base 203
COWELLMEDI HISTORY
Multi Scanbody 1.2 Hex.
Multi Digital Analog
Type Hex N-Hex Multi S & A
Ø4.5 Ø5.5
Abutment Diameter
D
Diameter Ø4.5 Ø4.5 Diameter
2.25 L Length Ø4.5 Ø5.5
H 2SMB001H 2SMB001N 2 2SMLA45 2SMLA55

> Packing unit : 1 Multi Scanbody + 1 Cylinder Screw. > Packing unit: 1 Multi Digital Analog.
> For both, model scanner and intra oral scanner. > Replacement of the Multi S or A Abutment shape in working cast.
D
> For the Multi Hybrid Ti-Base. > Used for both 3D printed model (RP) and stone model.
> Made of 100% titanium alloy with a special coating applied. > Select according to dimension of the Multi S or A Abutment.
> No need to spray.
Hex N-Hex > Connected with the Cylinder Screw (2SMCS100).
> Tightened with the 1.2 Hex Driver and Torque Wrench.

REID
> Tightening torque force : 15~20 N.cm.

COWELL® IMPLANT SYSTEM


Multi Pick-up Impression Coping Multi Hybrid Ti-Base
1.2 Hex.
Type Hex N-Hex
D
Diameter
8.522 mm
Type Hex N-Hex Ø4.5 Ø4.5 Ø5.5 Ø4.5 Ø4.5 Ø5.5
Cuff
Multi S & A 2.25
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5 0.5 2SMHT45H 2SMHT55H 2SMHT45N 2SMHT55N
Diameter
L Height Ø4.65 Ø5.65 Ø4.65 Ø5.65 C 1.5 2SMHT40H 2SMHT40N
D
9 2SMIH45 2SMIH55 2SMIN45 2SMIN55
> Packing unit : 1 Multi Hybrid Ti-Base + 1 Cylinder Screw.
> For Screw-Cement or Cement Retained Abutment.
> Packing unit: 1 Multi Pick-up Impression Coping + 1 Guide Pin (2SMGP012). Hex N-Hex > Titanium base for strength of CAD/CAM customized abutment or crown.
> For open tray impression.
> Gold color for more translucent restoration.
> Connected with the Guide Pin.
> Cutting surface for anti-rotation of prosthesis.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Hex N-Hex > Library available for EXOCAD®, 3Shape® & Others.
> Tightening torque force: 12~15 N.cm.
> Connected with the Cylinder Screw (2SMCS100).

COWELL® DIGITAL PRODUCTS


> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force : 30 N.cm.
> Use the Scanbody for 3D Work.
> Abutment level impression.

COWELL® EXPERT INSTRUMENTS


Multi Transfer Post Multi Cylinder Screw
Type Hex N-Hex Diameter
D Height Ø2.25
Multi S & A
Abutment Diameter Ø4.5 Ø5.5 Ø4.5 Ø5.5 1.2 Hex.
5 2SMCS100
Diameter
L Height Ø4.5 Ø5.5 Ø4.5 Ø5.5
D > Packing unit : 1 Multi Cylinder Screw.
7.5 2SMTH45 2SMTH55 2SMTN45 2SMTN55
> Connected with the Multi Scanbody, Multi Hybrid Ti-Base.
H > Tightened with the 1.2 Hex Driver and Torque Wrench.
> Packing unit: 1 Multi Transfer Post + 1 Guide Pin (2SMTHS100). > Tightening torque force : 30 N.cm.
> For closed tray impression.
Hex N-Hex > Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.

REGENERATIVE SOLUTION
COWELL®
204 InnoFit® Hybrid Ti-Base System : Sub-N. Multi Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Sub-N. Multi Hybrid Ti-Base 205
COWELLMEDI HISTORY
Component selection guide for • Intra-oral scanning
• Model-scanning
the Int. Hybrid Ti-Base System
Hybrid S Ti-Base
INT. 1.2 Hex
OCTAGON Type Octa N-Octa
SYSTEM 2.3 Platform
[Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
L
Diameter Ø5.1 Ø6.2 Ø5.1 Ø6.2
C
Length
Cuff 4 4 4 4

REID
D 0.8 ILO4814 ILO5914 ILN4814 ILN5914
Ø5.1 Ø6.2
2 ILO4824 ILO5924 ILN4824 ILN5924
Crown
3 ILO4834 ILO5934 ILN4834 ILN5934
Octa
> Packing unit: 1 Hybrid S Ti-Base + 1 Abutment Screw.
L
> For Screw-Cement or Cement Retained Abutment.
> Gold color for more translucent restoration.
C > Library available for EXOCAD®, 3Shape® & others.
> Connected with the Abutment Screw (ILHS100).
(Octa) (N-Octa) (Octa) (N-Octa) D > Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.

COWELL® IMPLANT SYSTEM


Hybrid S Ti-Base Hybrid L Ti-Base Ø5.1 Ø6.2 > Tightening torque force: 30 N.cm.
> Use the Scanbody for digital workflow.
> Fixture level impression.
N-Octa

Scanbody

Hybrid L Ti-Base

COWELL® DIGITAL PRODUCTS


1.2 Hex Type Octa N-Octa
Platform
2.3 [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
L
Diameter Ø5.1 Ø6.2 Ø5.1 Ø6.2
Digital Analog Digital Analog
C Length
Cuff 5.5 5.5 5.5 5.5
0.8 ILO4815 ILO5915 ILN4815 ILN5915
D

Ø5.1 Ø6.2 2 ILO4825 ILO5925 ILN4825 ILN5925


3 ILO4835 ILO5935 ILN4835 ILN5935
Octa
> Packing unit: 1 Hybrid L Ti-Base + 1 Abutment Screw.
> For Screw-Cement or Cement Retained Abutment.

COWELL® EXPERT INSTRUMENTS


> Gold color for more translucent restoration.
(Octa) (Octa) (N-Octa)
L > Library available for EXOCAD®, 3Shape® & others.
Scanbody Pick-up Impression Coping Transfer Post > Connected with the Abutment Screw (ILHS100).
C
> Tightened with the 1.2 Hex Ratchet Driver and Torque Wrench.
> Tightening torque force: 30 N.cm.
D
Intra-oral Model > Use the Scanbody for digital workflow.
Scanning Scanning Ø5.1 Ø6.2 > Fixture level impression.

N-Octa

REGENERATIVE SOLUTION
Healing

COWELL®
Fixture Cover Screw Headless Screw Abutment

206 InnoFit® Hybrid Ti-Base System : Int. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Int. Hybrid Ti-Base 207
COWELLMEDI HISTORY
Scanbody 1.2 Hex. Digital Analog
Type Octa Platform
Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
[Fixture Dia.]
D Platform D
[Fixture Dia.] Ø4.8 & Ø5.9 [Ø3.5 / Ø4.0 / Ø4.5, Ø5.0 / Ø6.0] Diameter
Ø4.8 Ø5.9
2.3 Height
Diameter
Length Ø4.5 13.5 IDR001R IDR001W
L
6 ISB406
H
10 ISB410
> Packing unit: 1 Digital Analog.
> Analog of fixture for working cast.
> Packing unit: 1 Scanbody + 1 Abutment Screw (ISHR110). > Used for both 3D printed model (RP) and stone model.
> For both intra-oral scanning and model-scanning. > Select according to fixture platform.
> Made of 100% titanium alloy with a special coating applied.
Octa
> No need to spray.
> Connected with the Abutment Screw (ISHR110).

REID
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.

COWELL® IMPLANT SYSTEM


Pick-up Impression Coping Abutment Screw
D
Type Octa 1.2 Hex
Diameter
Platform
Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Height 2.3
[Fixture Dia.] D
Diameter 8.6 ILHS100
L Length Ø5.5 Ø6.6
2 Pieces > Packing unit : 1 Abutment Screw.
10 IIOR001 IIOW001 H
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Packing unit : 1 Pick-up Impression Coping + 1 Guide Pin (IIOR001S). > Tightening torque force : 30 N.cm.
> For open tray impression.
> Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
Octa > Tightening torque force: 12~15 N.cm.

COWELL® DIGITAL PRODUCTS


Transfer Post
D

Type Octa N-Octa

COWELL® EXPERT INSTRUMENTS


Platform
L [Fixture Dia.] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0] Ø4.8 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.9 [Ø5.0 / Ø6.0]
Fixture Dia.
Length Ø4.8 Ø5.9 Ø4.8 Ø5.9
11.5 ITOR400 ITOW500 ITNR400 ITNW500
2 Pieces 1 Piece
> Packing unit: Octa - 1 Transfer Post + 1 Guide Pin (Regular: ITOR400S / Wide: ITOW500S)
N-Octa - 1 Transfer Post (solid screw).
> For closed tray impression.
Octa N-Octa > Connected with the Guide Pin.
> Tightened with the 1.2 Hex Driver and Torque Wrench.
> Tightening torque force: 12~15 N.cm.

REGENERATIVE SOLUTION
COWELL®
208 InnoFit® Hybrid Ti-Base System : Int. Hybrid Ti-Base InnoFit® Hybrid Ti-Base System : Int. Hybrid Ti-Base 209
COWELL® EXPERT INSTRUMENTS COWELL®
EXPERT
An Expert knows what makes the results INSTRUMENTS

MFS Kit (Multi-Functional Sinus™ Kit) Atraumatic Extraction Kit


Designed to perform maxillary sinus lifting. Aqua Membrane Lifter, Drill designs and Stopper Used for the immediate and effortless extraction of the root of the tooth with simple procedures.
System prevent perforation of sinus membrane. The kit includes all the instruments required
for both, crestal and lateral approach. Direct Surgical Guide Kit
Used for a flapless surgery. It can also serve as a guide for positioning the drill while measuring
Sinus Lift Kit the thickness of the buccal bone, thereby preventing bone resorption and reducing the burden
This revolutionary kit uses US Patented Modified Tap Drills and Spreaders in order to allow any on the patient.
dentists to easily lift, split, or condense surrounding bone with simple drilling. Dentists can expect
more predictable results, and patients can enjoy less traumatic surgeries with shorter chair time. AO4 Surgical Stent
An excellent guide template to place implant precisely, especially for AO4 or AO6 technique.
MFR Kit (Multi-Functional Removal™ Kit)
An ideal solution for fixture, abutment and screw removal without trauma and bone loss. Volume-up™ Guide System
Devised for preventing food penetration and forming natural cervical area by restoring contracted
InnoGenic™ GBR Kit
buccal alveolar bone & gingiva to the original shape and width.
An all-in-one solution for various types of GBR procedures

InnoGenic™ Autobone Harvester


Devised to harvest autogenous bone not only from the general site but also from the site
where the implant will be placed. More than 1cc of bone chips can be harvested within 10 seconds.

COWELL® BMP Trephine Kit


An easy-to-use kit with drills and instruments for block-type bone collection, failed fixture
removal, crestal & window approach sinus lift and bone chip extraction.
COWELLMEDI HISTORY
Multi-Functional Sinus™ Kit

MFS KIT [KSA004]


>G A comprehensive kit to approach direct & indirect maxillary sinus lift simply.

Aqua Ratchet Connector


Crestal Drill Stopper Point Ø2.2 Crestal Drill

REID
3
6
9
12
Aqua Syringe Connector
1mm 2mm 3mm 4mm 5mm 6mm 7mm 8mm 9mm 10mm 11mm 12mm

Ø2.2 X 13

Ø2.8 X 13

Ø3.3 X 13

Ø3.7 X 13

Ø4.2 X 13
Bone Carrier
Aqua Lifter Ø2.8 Ø3.3 Ø3.7 Ø4.2
Aqua Tube

COWELL® IMPLANT SYSTEM


Bone Condenser

COWELL® DIGITAL PRODUCTS


Depth Gauge
Torque Wrench

COWELL® EXPERT INSTRUMENTS


Sinus Elevator

Lateral Stopper Lateral Drill Side Cutter CSE-01

0.5
3

CSE-02
0.5mm 1mm 1.5mm 2mm 2.5mm 3mm

REGENERATIVE SOLUTION
COWELL®
CSE-03
Ø6 Lateral Ø6 Round Ø4

210 MFS KIT MFS KIT 211


COWELLMEDI HISTORY
Crestal Approach - Components 4. Crestal Drill Stopper
> Connected with a stopper to be drilled to the same length of the cartilage height of maxillary sinus which is measured by CT.
> If not equipped with CT, fasten the stopper one step lower than expected and gradually increase the length.

1. Point Drill 800~1,000 rpm


1 2 3
> Mark the point of perforation on cortical bone. 0mm 4 5 6 7 8
3.5mm 9 10 11
> In the case of the remaining bone height is as low as 3.5mm, pay more attention to drilling. 12
7mm

REID
Code KPD01S Drilling Depth 1mm 2mm 3mm 4mm 5mm 6mm
KSDS01 KSDS02 KSDS03 KSDS04 KSDS05 KSDS06

Drilling Depth 7mm 8mm 9mm 10mm 11mm 12mm


KSDS07 KSDS08 KSDS09 KSDS10 KSDS11 KSDS12

0mm
2. 2.2 Twist Drill 800~1,000 rpm

COWELL® IMPLANT SYSTEM


1mm
2mm
> Use for making guide hole before using the Crestal Drill.
3mm
5. Depth Gauge
> Use the Crestal Drill Stopper according to the height of the remaining bone. 4mm > Measure thickness of the residual bone after checking the perforation of the cartilage of the
maxillary sinus (do not open completely, only the entrance side is opened).
> The stopper is attached to the base of the residual bone to separate the cartilage and membrane
from the maxillary sinus.

Code KSTD22 12
9 Code KDG001S
6
3
0

COWELL® DIGITAL PRODUCTS


3. Crestal Drill 400~800 rpm
> Use the Crestal Drill sequentially according to the diameter of the fixture to be placed. 6. Aqua Membrane Lifter System
0mm
> Can also be used if sinus floor is flat, incline, septum. 1mm
2mm > After confirming that elevation of the cartilage of maxillary sinus, elevate membrane with the Aqua Membrane Lifter System.
> The Crestal Drill can be used about 50 times (depending on bone quality).
3mm Bone Height : 6mm ྙ Fasten the Aqua Lifer Drill to the drilled hole.
4mm ྚ Connect the Aqua Tube to syringe using the Syringe Connector (SC).
5mm
D ྛ Inject saline solution to the amount of bone graft material
ⴜ Membrane is elevated by
to be used for syringe.
injecting saline solution
ྜ Tube connection to the Lifter Drill using the Ratchet Connector (RC).

COWELL® EXPERT INSTRUMENTS


(0.1cc inject -> elevation
ྜྷ Inject saline solution. height 1mm).

୔ After injecting 0.2~0.5cc


Fixture Dia. Ø3.3 Ø3.5 Ø4.0 Ø4.5 / Ø5.0 Aqua Lifter Drill
and pressure is applied,
Diameter Ø2.8 Ø3.3 Ø3.7 Ø4.2 Aqua Lifter Drill ⴘ measure volume of injection
Code KSAL01 Aqua Ratchet Connector ⴛ and height of elevation.
KSCD28 KSCD33 KSCD37 KSCD42
Aqua Tube
୔ After elevation, injected saline
Aqua Ratchet Connector solution and blood are mixed.
ⴙ Aqua Syringe Connector
ⴚ Syringe
Code KSAL01RC

Diameter band 12 11 10 9 8 7 6 5 4 3 2 1
Ø2.8 Aqua Syringe Connector
Ø3.3 ୔ It is convenient to measure depth by ୔ Flat floor edge minimize damage

REGENERATIVE SOLUTION
Ø3.7
standard as a 3, 6, 9, 12mm. to membrane. Code KSAL01SC
Ø4.2

COWELL®
Aqua Tube
Code KSALT030

212 MFS KIT MFS KIT 213


COWELLMEDI HISTORY
7. Torque Wrench Crestal Approach - Drilling Sequence
> Use the Torque Wrench to fix the Aqua Lifer Drill in the hole formed using Crestal Drill. > Placing implant over Ø 4.0 is highly recommended.

Code KTW001
1. Ø3.3 Narrow Fixture

REID
8. Bone Carrier
Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill
> Insert bone graft material using the Bone Carrier.
Soft Bone Normal Bone
Ø3.9

2. Ø3.5 Fixture
Ø3.5

COWELL® IMPLANT SYSTEM


୔ If you need to expand hole,
Code KSBC01
drill 1mm more using the
crestal drill.

9. Bone Condenser Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill Ø3.3 Crestal Drill

> After connecting the stopper with the Bone Condenser, Soft Bone Normal Bone
elevate bone graft materials to inside of maxillary sinus. or
> Rotate bone graft material using the Bone Condenser to disperse bone
3. Ø4.0 Fixture

COWELL® DIGITAL PRODUCTS


graft material (possible to do with the Depth Gauge).
Ø2

୔ If you need to expand hole,


drill 1mm more using
the crestal drill.

Ø1
Code KSBC1022
Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill Ø3.3 Crestal Drill Ø3.7 Crestal Drill

Soft Bone Normal Bone

COWELL® EXPERT INSTRUMENTS


4. Ø4.5 Fixture
10. Implant Drill (Final)
> Drill 1~2mm more deeply than steps of the Crestal Drill.

Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill Ø3.3 Crestal Drill Ø3.7 Crestal Drill Ø4.2 Crestal Drill

Soft Bone Normal Bone


11. Implant Placement

REGENERATIVE SOLUTION
> If the residual bone is less than 3mm, do not implant the implant, ୔ Ø5.0 Fixture Normal Bone : Drilling with the Final Drill before placing implants are required.
but bone graft only. ୔ Use a Drill that is one step shorter than the implant (E.g. 10mm implant, 8~9mm Drill).

COWELL®
214 MFS KIT MFS KIT 215
COWELLMEDI HISTORY
Lateral Approach - Components > CSE-02 : as stepwise, after using CSE-01, used for elevation of sinus membrane.

1. Ø6 Lateral Reamer 800~1,000 rpm Code KSSE02

> Drill after fastening the stopper according to the height of the bone.
> Round shape to prevent membrane perforation.
> CSE-03 : as stepwise, after using CSE-02, used for elevation of sinus membrane.

REID
Code KSLD60

Code KSSE03

2. Ø6 Lateral Round Drill 800~1,000 rpm


5. Ø4 Side Cutter 800~1,000 rpm

COWELL® IMPLANT SYSTEM


> Drill after fastening the stopper according to the height of the bone.
> Round shaped edge. > When you expand window, must be connected with Stopper.
> The residual bone should be replaced in the original position after drilling,
sinus lifting & augmentation.

Code KSC60

Code KSLRD60

6. Sinus Bone Graft

COWELL® DIGITAL PRODUCTS


3. Lateral Stopper
0.5 1 1.5 2 2.5 3

Drilling Depth 0.5mm 1mm 1.5mm 2mm 2.5mm 3mm


KSDSL05 KSDSL10 KSDSL15 KSDSL20 KSDSL25 KSDSL30

COWELL® EXPERT INSTRUMENTS


7. Implant Drill (Final)

4. Sinus Elevator
> CSE-01 : Initial elevation of sinus membrane.

Code KSSE01

REGENERATIVE SOLUTION
8. Implant Placement

COWELL®
216 MFS KIT MFS KIT 217
COWELLMEDI HISTORY
Sinus Lift KIT [KSA001] Sinus Lift
Tap Drill (Ø3.6 ,Ø4.6)
>G Sinus Lift Kit is the world’s most innovating kit for performing maxillary sinus lift, ridge splits, and bone condensing cases. > The Tap Drill uses low speed and high torque to grind through the maxillary bone, and safely elevates sinus without membrane perforation.
> Must be used at 20 rpm / 40~45 N.cm.
This revolutionary kit uses US Patented modified Tap Drills and Spreaders in order to allow any dentists to easily lift, split, or > No irrigation is required.
condense surrounding bone with simple drilling. Dentists can expect more predictable results, and patients can enjoy less
traumatic surgeries with shorter chair time. Ø3.6S 2.7 2.85 D
Diameter Ø3.6 Ø4.6
KMTD36S KMTD46S
Ø4.6S 3.7 3.85 D

REID
Can be used with COWELLMEDI Torque Wrench using Ratchet Adapter.

10
8
35
30
6 25

10
Press the elastic handle with finger

COWELL® IMPLANT SYSTEM


4
to control the torque

Tip of the drill has U.S. Patented blade that crush through the
cortical bone, and separate sinus membrane without perforations.

Twist Drill (Ø3.6, Ø4.6)


> The Twist Drill is used after tapping as final drill for dense bone (Bone quality of 2 or greater), or to eliminate tapping thread in order to facilitate bone grafting.
> Must be used at 20 rpm / 40~45 N.cm.
For All Surgery Sinus Lift Spreader > No irrigation is required.
> Universally used Drills / used for both > Used in bone condensing or ridge split implantation. 10
sinus lift or ridge split.

COWELL® DIGITAL PRODUCTS


> Used in any maxillary sinus > Also used in maxillary sinus lift & immediate Ø3.6S D Used as Final Drill 9
for 4.2~4.5 Fixture 8
> Drilling must be accompanied with implantation. placement cases. Diameter Ø3.6 Ø4.6 7
copious amounts of refrigerated sterile 6
irrigation. KTWD36S KTWD46S 5
Ø4.6S D Used as Final Drill 4
for 5.2~5.5 Fixture 3
Drill Speed : 800-2,000 rpm Drill Speed : 20-30 rpm Drill Speed : 20-30 rpm
Torque : 45 N.cm Torque : 45 N.cm

Ø4.0 fixture Ø5.0 fixture


Spreader
Tap Drill (Ø3.2 , Ø3.8, Ø4.2, Ø4.8, Ø5.1)
Ø5.1S
Ø4.2S
Ø3.2S
Ø3.6S

Ø4.6S

COWELL® EXPERT INSTRUMENTS


Point Drill Adapter > The Spreader Drill is used to condense and/or spread the bone in either sinus lift or ridge split cases.
KPD01S KRA20L > Must be used at 20 rpm / 40~45 N.cm.
Ø4.6 Tap Ø5.1
> No irrigation is required.
Ø3.6 Tap Ø3.2 Ø4.2
KMTD36S KMTD46S KMTD32S KMTD42S KMTD51S
For manual operation
using Torque Wrench, Ø3.2S 1.9 D Diameter Ø3.2 Ø3.8 Ø4.2 Ø4.8 Ø5.1
Ø2.2S

Adapter need to
connect Machine Driver KMTD32S KMTD38S KMTD42S KMTD48S KMTD51S
with Torque Wrench Ø3.8S 2.5 D
Ø4.6S
Ø3.6S

Ø3.8S

Ø4.8S

Ø2.2 Drill Ø4.2S 2.9 D


KTWD22S Can be used with COWELLMEDI Torque Wrench using Ratchet Adapter.
12
Ø3.6 Drill Ø4.6 Drill Ø3.8 Ø4.8 Ø4.8S 3.5 D 10
KTWD36S KTWD46S KMTD38S KMTD48S 8
6 Tip of the drill has U.S. Patented blade that crush through the
Ø2.9SL

Ø5.1S 3.8 D
cortical bone, and separate sinus membrane without perforations.

REGENERATIVE SOLUTION
4

COWELL®
Ø2.9 Drill Torque Wrench
KTWD29SL KTW001

218 Sinus Lift KIT Sinus Lift KIT 219


COWELLMEDI HISTORY
Sequence -Sinus Lift
Only use of Sinus Lift Drill Immediate Implantation and Sinus Lift Technique with Tap Drill (Ø5.0 Fixture)

1. Sinus Lift (Ø4.0 Fixture)


SinusGMembrane
Cortical Bone piece after Cortical Bone
perforation by the Tap Drill

Use as Final Drill when

REID
placing Ø4.2~Ø4.5 fixture
(Drilling under 30 rpm)
Drill Speed : 20~30 rpm
Ø3.6GDrill Torque : 45 N.cm
Recommend to lift under 3mm

Recommend to use Sinus Lift Drill and Spreader Drill together

COWELL® IMPLANT SYSTEM


Bone
Point Drill Ø2.2 Drill Ø3.6GTap Graft Fixture Placement
S

Drill Speed : 800~2,000 rpm Drill Speed : 800~2,000 rpm Drill Speed : 20~30 rpm
Torque : 45 N.cm If excessive torque occurs
Bone Graft using
Osteotome etc. when using Ø3.8 Spreader,
ⲼOptional
replace to Ø3.6 Tap Drill then
1. Sinus Lift (Ø4.0 Fixture)  bone graft
Drill Speed : 20~30 rpm
Torque : 45 N.cm
Immediate Implantation and Sinus Lift Technique with Tap Drill (Ø4.0 Fixture)
Ø3.6 Tap

COWELL® DIGITAL PRODUCTS


Ø3.2 Ø3.8 Bone Fixture
Point Drill Ø2.2 Drill Spreader Spreader Graft Placement
Drill Speed : 800~2,000 rpm Drill Speed : 800~2,000 rpm Drill Speed : 20~30 rpm Drill Speed : 20~30 rpm
Torque : 45 N.cm Torque : 45 N.cm Bone Graft using
Osteotome etc.
ⲼOptional

Use as Final Drill when


2. Sinus Lift (Ø5.0 Fixture) placing Ø5.2~Ø5.5 fixture

COWELL® EXPERT INSTRUMENTS


(Drilling under 30 rpm) If excessive torque occurs,
replace to Ø4.6 Tap Drill
Drill Speed : 20~30 rpm then bone graft
Torque : 45 N.cm
Recommend to Ø4.6 Drill Drill Speed : 20~30 rpm
lift under 3mm 2. Sinus Lift (Ø5.0 Fixture) Torque : 45 N.cm

Ø4.6 Tap

Bone
Point Drill Ø2.2 Drill Ø2.9 Drill Ø4.6GTap Graft Fixture Placement
Drill Speed : 800~2,000 rpm Drill Speed : 800~2,000 rpm Drill Speed : 800~2,000 rpm Drill Speed : 20~30 rpm
Torque : 45 N.cm Ø3.2 Ø3.8 Ø4.2 Ø4.8 Bone Fixture
Bone Graft using Point Drill Ø2.2 Drill Spreader Spreader Spreader Spreader Graft ᜾พ

REGENERATIVE SOLUTION
Osteotome etc.
ⲼOptional Drill Speed : 800~2,000 rpm Drill Speed : 20~30 rpm
Torque : 45 N.cm Bone Graft using
Osteotome etc.

COWELL®
ⲼOptional

220 Sinus Lift KIT Sinus Lift KIT 221


COWELLMEDI HISTORY
Note
>GRecommend to use Sinus Lift Drill and Spreader Drill together during the Sinus Lift operation. Ridge Split and Block Bone Augmentation Technique with Spreader Drill (Ø4.0 Fixture)
> Easily operate by using Ø3.2 Spreader rather than Point Drill.
G

>GAvoid to over press surrounding alveolar bone using Final Drill before fixture placement in D2.

ex) Ø4.0 Fixture placement


3mm

REID
Bone
Point Drill Ø2.2 Drill Ø3.6GTap Graft Final drill Insertion of Fixture

COWELL® IMPLANT SYSTEM


Sequence-Spreader
Drill Speed : 20~30 rpm
Torque : 45 N.cm
Use Round Bur or Chisel etc.
Mark the placing area
Ø3.2 Ø3.8 Ø4.2 Ø4.8
Ø Ø
Ø5.1
Ø3.8S
Ø3.2S

Ø4.2S

Ø4.8S

Ø5.1S
ⲼOptional Spreader Spreader Spreader Spreader
S Spreader
S

COWELL® DIGITAL PRODUCTS


4PGU#POF )BSE#POF 4PGU#POF )BSE#POF

Ø3.3(3.5) Ø4.0 Fixture Ø5.0 Fixture


Fixture ⲼRecommend to use Tapered Fixture ⲼRecommend to use Tapered Fixture

COWELL® EXPERT INSTRUMENTS


REGENERATIVE SOLUTION
COWELL®
222 Sinus Lift KIT Sinus Lift KIT 223
COWELLMEDI HISTORY
Multi-Functional Removal™ Kit MFR Kit - Components
MFR KIT [KHA001] 1. Fixture Removal System
ྙ Connect the F/R Screw to the FRS Driver.
ྚ Connect the F/R Screw mounted FRS Driver to the fixture (clockwise 40~60 N.cm) and remove the FRS Driver.
>G Easy removal of fractured fixture / screw / abutment. ྛ Connect the Fixture Remover to the F/R Screw (counterclockwise).
Abutment Removal System ྜ Remove the fixture after connecting the Torque Wrench (counterclockwise, 100~400 N.cm).
Abutment Remover ྜྷ To remove the fixture from the Fixture remover, use such device as vise to fix the Fixture Remover and connect to the Torque Wrench.
ྞ After connecting the FRS Driver to the F/R Screw, use the Torque Wrench to remove the F/R Screw (counterclockwise).

REID
Abutment Removal Abutment Removal
KART01 / KART02 KART03

M1.6 M2.0 M2.5

Tap Repair ⴛ



Tap Repair Driver ⴚ
KTR16 / KTR20 / KTR25

COWELL® IMPLANT SYSTEM


M1.6 M2.0 M2.5 ⴝ
Slot Machine
Driver Adapter

Slot Driver Machine Adapter


KHD0827 KRA13

୔ One-time use of the F/R Screw is recommended (bending or fracture may happen if more than 100 N.cm
and using twice may be possible if less than 100 N.cm).
୔ Sufficient irrigation required for removing the fixture.
Fixture Removal System Screw Removal System ୔ When the maximum torque is exceeded, the fixture may be bent or fractured.

COWELL® DIGITAL PRODUCTS


F/R Screw ୔ If the fixture can not be removed even with maximum torque, remove the Fixture Remover & F/R Screw,
Talon Reverse Screw
Drill Drill Remover remove bones around fixture using round bur and retry to remove.

M1.6
Fixture Removal Screw
KFRS16
Fixture Removal Screw
KFRS20
Fixture Removal Screw
KFRS25
2. Screw Removal System
M1.6 M2.0 M2.5 Talon Drill
Fixture Remover FRS Driver ྙ Check the broken screw size inside the fixture.
M2.0
ྚ Connect the I Guide corresponding to the fixture
Ø3~Ø4
to the Guide Holder and fasten to the fixture.
Fixture Removal Fixture Removal(Sub. Narrow)
Talon Drill Reverse Guide Screw ྛ Insert the Talon Drill into the I Guide Hole.
KFR3515 / KFR3520 KFRSD13 / KFRSD18

COWELL® EXPERT INSTRUMENTS


(Claw Drill) Drill Remover
M2.5 ྜ Remove the screw by pressing force (counterclockwise, 60~80 rpm).
KSRCD08 KSRGD08 KSRSR08
KSRCD12 KSRGD12 KSRSR12
KSRCD14 KSRGD14 KSRSR14
Ø4~Ø5
Fixture Removal
KFR4015 / KFR4020 ⴛ
I Guide


Ø5~Ø6 Fixture Removal I Guide (Sub. 2.5 Hex) I Guide (Int. 3.1 Octa) ⴙ
KFR5015 / KFR5020 KSRIG25H KSRIG31O
Torque Wrench
KTW002 Silicon O-Ring KSRIGO01

Ø6~Ø8 Fixture Removal


KFR6015 / KFR6020

REGENERATIVE SOLUTION

COWELL®
Guide Holder KSRGH01

୔ If the I Guide and fixture could not be correctly connected, the path is not correct.

224 MFR KIT MFR KIT 225


COWELLMEDI HISTORY
Reverse Drill & Screw Remover Tap Repair
If the screw could not be removed by the Talon Drill ྙ Used when the thread inside the fixture is occluded and damaged.
ྙ Form the hole on the fractured screw (depth 1~2mm / counterclockwise / 1,200~1,400 rpm). ྚ Reproduce the thread using the Tap Repair. ⴙ
ྚ Use the Screw Remover according to the created drill hole, remove the screw by pressing force (counterclockwise, 80 N.cm). ⴘ

REID
Slot Driver
ྙ Used for the damaged solid abutment (1piece type), healing abutment and cover screw.
ྚ Form a slot on the surface of the damaged abutment using round bur.

ྛ Connect the Slot Driver to the formed slot and remove it (counterclockwise).

COWELL® IMPLANT SYSTEM


Reverse Drill Screw Remover

୔ If the path of the I Guide and fixture did not match, it is difficult to remove the screw because the drill hole is away from
the center of the screw.
୔ Reverse drilling requires removal of chips by irrigation & suction.
୔ The fractured screw may be removed during reverse drill hole creation.
୔ If necessary, fasten to the Machine Adapter and use the hand or Torque Wrench.

COWELL® DIGITAL PRODUCTS


4. Torque Wrench

3. Abutment Removal System

COWELL® EXPERT INSTRUMENTS


Abutment Remover Place the fixture
ྙ Used when 2 piece type abutment is fractured. (clockwise, 40~80 N.cm).
ྚ Connect to the Abutment Remover (clockwise).
ྛ Connect correctly and wiggle to left and right side.



Remove the fixture


(counterclockwise, 100~400 N.cm).

REGENERATIVE SOLUTION
COWELL®
226 MFR KIT MFR KIT 227
COWELLMEDI HISTORY
InnoGenic™ GBR Kit [KIGBR001]
>G An all-in-one solution for various types of GBR procedures.
3mm 7mm
KIGFS03 KIGTS07

KIGFS03 KIGTS07

1513 10 7 5 3 0
The length of the product can KIGFS03 KIGTS07
be measured with the scale
marked on the middle tray of KIGFS03 KIGTS07
the kit.

REID
KIGFS03 10mm

0 3 5 7 10 1315
KIGTS10
5mm
Fixing Screw Drill
KIGFS05 KIGTS10
KFSD10

Bone

Bone
KIGFS05 KIGTS10

Drill
Tenting Screw Drill

Tenting Screw
Fixing Screw
KIGFS05 KIGTS10
KTSD14

KIGFS05 13mm

COWELL® IMPLANT SYSTEM


KIGTS13
KIGFS05
3mm
KIGTS13
KIGDS03 7mm
Drill Stopper

KIGFS07 KIGTS13
5mm
KIGDS05
KIGFS07 KIGTS13
7mm Screw Kit
KIGICS001 KIGFS07 15mm
KIGDS07
KIGTS15
KIGFS07
KIGTS15
Machine KIGFS07
KFSMD24 KIGTS15

COWELL® DIGITAL PRODUCTS


Fixing
Handle KIGTS15
KFSHD70
Driver

0.3mm
Machine KIGTC32
KTSMD24

Tenting Cap

T/Cap

0.3mm
Tenting KIGTC32
Handle

0.3mm
KTSHD70 KIGTC32

COWELL® EXPERT INSTRUMENTS


Fix Connector Cover Cap Healing Cap
Harvesting Drill F/Connector Fixture C/Cap H/Cap

Driver Handle Round Bur Bone Trimmer Ø3.5 Drill Ø5.0 Drill 0.9 Hex 0.5mm 0.5mm 1.0mm 1.0mm 1.5mm 1.5mm 2.0mm 2.0mm Ø4.5 Ø4.5(3mm) Ø4.5(3mm) Ø4.5(4mm) Ø4.5(4mm)
KIGH KIGRB10 KIGBT50 KBH35 KBH50 KHD0921 KIGFC4505 KIGFC4505 KIGFC4510 KIGFC4510 KIGFC4515 KIGFC4515 KIGFC4520 KIGFC4520 KIGCC45 KIGHC453 KIGHC453 KIGHC454 KIGHC454

Ø4.5 Ø5.5(3mm) Ø5.5(3mm) Ø5.5(4mm) Ø5.5(4mm)


KIGCC45 KIGHC553 KIGHC553 KIGHC554 KIGHC554

REGENERATIVE SOLUTION
Silicon Shield

COWELL®
KBHDSS01
1EA assembled with Drill.
5EA packed in the lower tray.

228 InnoGenic™ GBR Kit InnoGenic™ GBR Kit 229


COWELLMEDI HISTORY
Bone
D
Screw Kit KIGICS001 Fixing Screw (Fixing)
C

• Used without removing the Screw Kit from the • Used to fix the membrane to the bone.
inside of the kit tray (Remove to use if necessary • Place slowly using the Fixing Driver (Machine/Handle). L H
only). Double
• 3, 5 and 7mm length can be selected according to the bone quality. Thread
• Made of special material for autoclaving. In hard bone, use after forming a basic drill hole using the Fixing Screw Drill.

REID
Wedge-shaped
• The wedge-shaped design is advantageous for self-tapping, allowing it to be
* Rotate the upper lid to take out the selected product. design
Ø1.4
fixed without drilling in normal bone.
* • The double thread shortens the placement time.

Membrane
D(Ø,mm) C(mm) L(mm) H(mm) Code
Fixing Screw
Composition 3.0 3.6 KIGFS03 (5mm)

COWELL® IMPLANT SYSTEM


Fixing Screw
Classification Product Code Quantity 2.0 0.6 5.0 5.6 KIGFS05 (3mm)

KIGFS03 5 7.0 7.6 KIGFS07


Fixing Screw KIGFS05 5
(Fixing)
KIGFS07 5

KIGTS07 4
Bone
KIGTS10 4
Bone
Tenting Screw
(Tenting)
KIGTS13 4 Tenting Screw (Tenting)

COWELL® DIGITAL PRODUCTS


KIGTS15 4 • Used when a large area of vertical / horizontal GBR is required. D

Leave space for bone grafts.


Tenting Cap (T/Cap) KIGTC32 3
• Place slowly using the Tenting Screw Driver (Machine/Handle). C

KIGFC4505 2 • Recommended placement depth : Hard bone-3mm, Normal bone-5mm,


Soft bone-more than 5mm.
KIGFC4510 2
Fix Connector • Initial fixation of at least 15~25 N.cm is required. Tightening more than
(F/Connector) KIGFC4515 2 35 N.cm may cause fracture of the Tenting Screw so it must be fixed Double L H
below 35 N.cm. Thread
KIGFC4520 2 • In normal bone, it is recommended to form a hole at least 3mm deep
using the Tenting Screw Drill before placing the Tenting Screw.
Fixture Cover Cap (C/Cap) KIGCC45 2

COWELL® EXPERT INSTRUMENTS


• The wedge-shaped design is advantageous for self tapping, allowing it to Wedge-shaped
KIGHC453 2 design
be used without drilling in normal bone.
• The double thread shortens the placement time. Ø2.0
KIGHC454 2
Healing Cap • Use the Tenting Cap if necessary
(H/Cap) KIGHC553 2

KIGHC554 2 Tenting Screw


D(Ø,mm) C(mm) L(mm) H(mm) Code

7.0 9.5 KIGTS07

10.0 12.5 KIGTS10


Empty Screw Kit KIGICS 3.2 2.5
13.0 15.5 KIGTS13

REGENERATIVE SOLUTION
15.0 17.5 KIGTS15

COWELL®
230 InnoGenic™ GBR Kit InnoGenic™ GBR Kit 231
COWELLMEDI HISTORY
D D

C C

Bone Fixture
L H L H
Tenting Cap (T/Cap) Cover Cap (C/Cap)
• Used to fix membrane on the Tenting Screw.
• Used to fix membrane over the Fix Connector.
• Tightened with the 0.9 Hex Driver.

REID
• For submerged surgery in case of sufficient soft tissue.
• Recommended tightening torque force : 5~8 N.cm. Tenting Cap (T/Cap) Cover Cap (C/Cap)
• Recommended tightened with the 0.9 Hex Driver.
• Recommended tightening torque force: 5~8 N.cm. Membrane
Membrane
Fix Connector (F/Connector)
D(Ø,mm) C(mm) L(mm) H(mm) Code Tenting Screw

3.2 0.3 2.8 3.1 KIGTC32 D(Ø,mm) C(mm) L(mm) H(mm) Code

4.5 0.3 3.4 3.7 KIGCC45

COWELL® IMPLANT SYSTEM


D D
Fixture Fixture

COWELL® DIGITAL PRODUCTS


C
Fix Connector (F/Connector) Healing Cap (H/Cap) C

• Used to fix the membrane along with the Cover Cap or Healing • Used to fix membrane over the Fix Connector. H
L H
Cap after connecting to the fixture. • For non-submerged surgery in case of insufficient soft tissue. L
• Tightened with the 0.9 Hex Driver. • Connect by using the 0.9 Hex Driver.
• Recommended tightening torque force: 12~15 N.cm. • Recommended tightening torque force: 5~8 N.cm.
• Available for the INNO Submerged, Submerged Short Fixtures
and other fixtures compatible with them only.
Healing Cap (H/Cap)

Fix Connector (F/Connector) D(Ø,mm) C(mm) L(mm) H(mm) Code


D(Ø,mm) C(mm) L(mm) H(mm) Code

COWELL® EXPERT INSTRUMENTS


0.5 6.2 KIGFC4505 3.0 6.4 KIGHC453
4.5 Fix Connector (F/Connector)

1.0 6.7 KIGFC4510 4.0 7.4 KIGHC454


4.5 5.7 3.4
1.5 7.2 KIGFC4515 3.0 6.4 KIGHC553
5.5
2.0 7.7 KIGFC4520 4.0 7.4 KIGHC554

REGENERATIVE SOLUTION
COWELL®
232 InnoGenic™ GBR Kit InnoGenic™ GBR Kit 233
COWELLMEDI HISTORY
Fixing Screw Drill & Tenting Screw Drill Fixing Screw Driver & Tenting Screw Driver (Machine)
H
• Used to place the Fixing Screw / Tenting Screw mainly in hard bone. • Used to place the Fixing Screw / Tenting Screw using Contra-angle.
• Also used to perforate cortical bone when blood supply is required. • Color-banded for distinction (Red : Fixing Screw Driver, Blue : Tenting Screw Driver).
• For normal bone, drill only 3mm deep if necessary.

REID
• Drill before placing the Fixing Screw / Tenting Screw.
• Laser-marked at 3, 5 and 7mm long from the tip of the drill and the length can be Classification D(Ø,mm) L(mm) H(mm) Code Color band

controllable using the Drill Stoppers. H Fixing Screw 1.6 KFSMD24


Driver L
• Color-banded for distinction (Red : Fixing Screw Drill, Blue : Tenting Screw Drill). 6.0 24.0 Fixing Driver (Machine)
Tenting Screw 2.2 KTSMD24 D
• Recommended drilling speed : 1,000~1,200 rpm. Driver Tenting Driver (Machine)

Classification D(Ø,mm) L(mm) H(mm) Code Color band


7mm

Fixing Screw 5mm L

COWELL® IMPLANT SYSTEM


1.0 KFSD10
Drill 31.5 3mm
10
Tenting Screw Fixing Screw Drill D
Drill 1.4 KTSD14 Tenting Screw Drill
Fixing Screw Driver & Tenting Screw Driver (Handle)
• Used to place the Fixing Screw / Tenting Screw using the Driver Handle.
Drill Stopper • Color-banded for distinction (Red : Fixing Screw Driver, Blue : Tenting Screw Driver).
H
• Used by connecting to the Fixing Screw Drill / Tenting Screw Drill. L
Color band
• 3mm : Yellow, 5mm : Red, 7mm : Blue

D D
Fixing Driver (Handle)

COWELL® DIGITAL PRODUCTS


D Tenting Driver (Handle)
D

H
H H
Classification D(Ø,mm) L(mm) H(mm) Code
Fixing Screw 1.6 KFSHD70
Driver
6.0 70.0
Tenting Screw 2.2 KTSHD70
Driver
Classification D(Ø,mm) H(mm) Code

3mm 13.5 KIGDS03

5mm 3.5 11.5 KIGDS05

COWELL® EXPERT INSTRUMENTS


7mm
7mm 9.5 KIGDS07 3mm
5mm Driver Handle
Driver
• Used to place and remove the Fixing Screw / Tenting Screw by connecting Handle
the Handle Driver.
H
0.9 Hex Driver (Ratchet) L

• Used to install the Tenting Cap, Fix Connector, Cover Cap and Healing Cap.
D
H
D(Ø,mm) L(mm) H(mm) Code
L
8 15 *KHD0915
D
D(Ø,mm) L(mm) H(mm) Code Fixing Tenting
1.2 14 21 KHD0921

REGENERATIVE SOLUTION
Screw Driver Screw Driver

20 27 *KHD0927 19.8 75 135.0 KIGH


Fixing Screw Tenting Screw

COWELL®
* Optional

234 InnoGenic™ GBR Kit InnoGenic™ GBR Kit 235


COWELLMEDI HISTORY
Round Bur Harvesting Drill & Drill Stopper
• Used to perforate cortical bone when blood supply is required. • Drill for convenient harvesting of autogenous bone in the form of bone chip in a short period of time.
• Recommended drilling speed : 1,200~1,500 rpm. • The Silicon Shield of the Ø3.5 Harvesting Drill makes sure with no bone chip loss while drilling
H (Bone chip can be collected at implant site).

REID
L • 6 Silicon Shields are included in the Kit (1 is assembled with the Ø3.5 Harvesting Drill and 5 are
packed in the lower tray).
D
• The maximum drilling depth of the Ø3.5 Harvesting Drill is 12mm, so it needs to be drilled slowly.
• Remove while rotating the drill.
• Recommended drilling speed : 300~500 rpm. H L H L
D(Ø,mm) L(mm) H(mm) Code
D
1.0 9.5 34.0 KIGRB10 D(Ø,mm) L(mm) H(mm) Code D

3.5 9.5 39.2 KBH35

COWELL® IMPLANT SYSTEM


H H
5.0 6.5 36.5 KBH50

D(Ø,mm) H(mm) Code


Drill
5.6 9 KBHD3540
Bone Trimmer Stopper
D
D

6 14.3 KBHD4550
• Used to perform osteoplasty on the outer wall of remaining bone all during * Refer to the Innogenic™ Autobone Harverst Kit Catalog for details.
GBR and to flat the bone surface for improving the fit of membrane.
• Used to remove remaining granulation tissue of bone defect part (use instead
of surgical curette).

COWELL® DIGITAL PRODUCTS


• Recommended drilling speed : 1,200~1,500 rpm.
H
L
Bone Carrier
D • Narrow tip is beneficially handled in most of the bone graft techniques.
• Bone graft particles can be accurately and safely injected without contamination.
• rhBMP-2 can be easily coated to the implant due to circular groove of tip.
D(Ø,mm) L(mm) H(mm) Code • Bone graft particles and rhBMP-2 solution can be well mixed on the circular groove.

5.0 13 34.0 KIGBT50 H

COWELL® EXPERT INSTRUMENTS


Ø6
Ø14

114mm

0.4 cc

* Bone Carrier length is 94mm and the total length


after stretching is 114mm.

D(Ø,mm) H(mm) Code


Bone Carrier
6 94 KBBC01

REGENERATIVE SOLUTION
COWELL®
236 InnoGenic™ GBR Kit InnoGenic™ GBR Kit 237
COWELLMEDI HISTORY
InnoGenic™ Autobone Harvester [KIAH001]
Key Concepts
>G Maximize Your Return On Minimal Investment, Guaranteed!
Maximize your return on minimal investment
The key concept of the Autobone Harvester Plus to harvest a large amount of the autogenous
bone chips from the implant site that can be wasted into the suction during implant drilling procedure.

REID
Features: Drill

Longer
Manufactured after numerous times and various types of test;
Use longer and more times, compared to other products in the market.

COWELL® IMPLANT SYSTEM


Diverse
Diverse dimensions (Ø3.5, 4.0, 4.5, 5.0 & 6.0mm)
allow to harvest different volume of bone chips according
to clinical indications.

Easy to identify
The Color Painting helps choose the right Drill easy.
Ø3.5 Yellow Ø4.0 Orange Ø4.5 Green

COWELL® DIGITAL PRODUCTS


Harvesting Drill
Ø5.0 Blue Ø6.0 Purple

Drilling
Depth :
5~7 mm
Simple
The Stopper Holder is fastened with the Stopper and moves
forward and backward when drilling, and it is simple to
control drilling depth up to 5 to 7mm.
Ø3.5 Dril Ø4.0 Dril Ø4.5 Dril Ø5.0 Dril Ø6.0 Dril
KBH35 KBH40 KBH45 KBH50 KBH60

COWELL® EXPERT INSTRUMENTS


No Loss
The propeller shaped Drill design brings
Drill Stopper Silicon Shield * 1EA assembled with Drill. the bone chips into the Stopper without
5EA packed in the lower tray. the bone chip being lost.

Ø3.5 / 4.0 Ø4.5 / 5.0 Ø6.0  Safe


Drill Stopper Drill Stopper Drill Stopper The non-slip point design plays a guide
role in anti-slip while drilling.

REGENERATIVE SOLUTION
KBHD3540 KBHD4550 KBHD60 KBHDSS01

COWELL®
238 InnoGenic™ Autobone Harvester InnoGenic™ Autobone Harvester 239
COWELLMEDI HISTORY
Features: Stopper & Silicon Shield Harvesting sequence :
Implant Site using Ø3.5/4.0
For Ø3.5 & 4.0 Drill
Harvesting Drill with the Silicon Shield
Stopper
Used by fastening to the

REID
Stopper Holder of Ø3.5 & 4.0 Drill.
Drilling Depth
: 7mm

Silicon Shield (*Exclusive for Ø3.5 & 4.0)


- Used by fastening to Ø3.5 & 4.0 stopper. Shield
- Prevents deviation of bone chips. The lip-shaped shield is brought
• Point drill to mark harvesting and implant site. • Select Ø3.5/4.0 Drill and insert the Stopper • Drill at 300 to 500 rpm with irrigation and

COWELL® IMPLANT SYSTEM


- Allows bone chip harvesting from the implant site. into close contact with the bone
into the selected Drill. And put the Shield harvest bone chips.
- Reusable transparent silicon material allows to check and makes sure with no bone chip on the Ø3.5&4.0 Stopper.
drilling position and bone chips being harvested. loss while drilling.

For Ø4.5 & 5.0 Drill

COWELL® DIGITAL PRODUCTS


• Disassemble the Silicon Shield, the Stopper • Use Final Drill (equal to or over Ø3.5/4.0) • Place the implant.
and collect the bone chips for bone grafting. according to the drilling protocol of the
Stopper manufacturer and treatment planning.
Used by fastening to the
Stopper Holder of Ø4.5 & 5.0 Drill.
Drilling Depth
: 5mm

COWELL® EXPERT INSTRUMENTS


• Apply the harvested bone chips on the site.

Drilling Depth
For 6.0 Drill : 5mm

Stopper
Used by fastening to the
Stopper Holder of Ø6.0 Drill.

REGENERATIVE SOLUTION
COWELL®
240 InnoGenic™ Autobone Harvester InnoGenic™ Autobone Harvester 241
COWELLMEDI HISTORY
Harvesting sequence :
COWELL® BMP TREPHINE KIT [KBT001]
Buccal Bone Harvesting
>G An easy-to-use kit with drills and instruments for block-type bone collection, failed fixture removal,
using Ø3.5/4.0/4.5/5.0/6.0 crestal & window approach sinus lift and bone chip extraction.

Harvesting Drill

REID
Select the drill according to its * For Ø3.5&4.0 Harvesting Drill,
using with the Silicon Shield is
diameter and clinical indications. highly recommended.

COWELL® IMPLANT SYSTEM


• Drill at 300 to 500 rpm with irrigation and harvest autogenous bone chips. • Apply the harvested bone chips on the site.

Trephine Drill IBlock Bone Extraction

A Clinical Case using Ø3.5/4.0 Harvesting Drill Guide & Block Bone Trephine Drill
Trephine Drill II Trephine Drill III

COWELL® DIGITAL PRODUCTS


Failed Fixture Removal Window Opening for
by Dr. Soohong Kim, DDS, Ph.D Lateral Window Approach
Fixture Removal Window Trephine

Ø6 Ø7 Ø8
Drilling at 300 rpm with irrigation was carried out The Silicone Shield was brought into close contact The amount of bone taken was easily ascertained,
after marking implant and harvesting position. with various types of bone level and prevented through the transparent Silicone Shield.
bone chip loss. Ø4 Ø4.5 Ø5 Ø7

COWELL® EXPERT INSTRUMENTS


1SPEVDU %JBNFUFS $PEF

Ø 6.0 (Inner) KBGT60

Block bone Guide Drill Ø 7.0 (Inner) KBGT70

Ø 8.0 (Inner) KBGT80

Ø 6.0 (Inner) KBT60


Implant Site DrillSinus Lift & Bone Chip Extraction Block Bone Trephine Drill Ø 7.0 (Inner) KBT70
Prior to Implant Placement
The bone was transferred to bone dish after disassembling the Silicon Shield and Stopper. After the implant placement, healing abutments were Implant Site Ø 8.0 (Inner) KBT80
The amount of the bone was much more than expected. connected and carried out GBR in the defected area.
Ø 4.2 (Inner) KFRT40

Fixture Removal Trephine Drill Ø 4.7 (Inner) KFRT45

* 2 Step Harvesting : Drilling to 7mm is recommended after transferring bone chips to bowl since the Stopper & Silicon Shield are fully filled Ø 5.2 (Inner) KFRT50
with bone chips while 4mm drilling. Window Trephine Drill Ø 7.0 (Outer) KWTT60

REGENERATIVE SOLUTION
Ø 3.5 (Fixture) KTIS35

Ø 4.0 (Fixture) KTIS40

COWELL®
Implant Site Drill
Ø3.5 Ø4 Ø4.5 Ø5 Ø 4.5 (Fixture) KTIS45

Ø 5.0 (Fixture) KTIS50

242 InnoGenic™ Autobone Harvester COWELL® BMP Trephine Kit 243


COWELLMEDI HISTORY
Trephine Drill I Block Bone Extraction Trephine Drill III Window Opening for Lateral Window Approach
This Drill allows the collection of block-type autogenous bone with a required size in the case of regenerating a wide bone
defect and severe bone resorption. Diameter Ø 7.0 (Outer)
KWTT60
Block Bone Guide Block Bone Trephine Drill
> This guide helps the target block bone to be accurately > This drill is engaged with the bone groove with the help
positioned and the Trephine Drill to be stably engaged of the block bone guide to collect the block bone
with the bone. with a desired size.
> Desired rpm: 800~1,000 rpm. > Desired rpm: 800~1,000 rpm.
0.5

The root apex of the guide

REID
drill is projected 0.5mm

Ø6

Ø7

Ø8
Ø6

Ø7

Ø8 more than the cutting part,


so that the drilling can be
guided.

7.5 Ø 7.0
7
5
3

0
Ø 6.0 Ø 7.0 Ø 8.0 Ø 6.0 Ø 7.0 Ø 8.0

COWELL® IMPLANT SYSTEM


Ø 7.0 Ø 8.0 Ø 9.0 Ø 7.0 Ø 8.0 Ø 9.0

Implant Site Drill Sinus Lift & Bone Chip Extraction Prior to Implant Placement
Diameter Ø 6.0 (Inner) Ø 7.0 (Inner) Ø 8.0 (Inner) Diameter Ø 6.0 (Inner) Ø 7.0 (Inner) Ø 8.0 (Inner)
KBGT60 KBGT70 KBGT80 KBT60 KBT70 KBT80 Diameter Ø 3.5 Ø 4.0 Ø 4.5 Ø 5.0
KTIS35 KTIS40 KTIS45 KTIS50
ⴙ ⴘ

> Used before the final drill is used (simplified drilling sequence).
> Advantageous for securing autogenous bone.
> Less rpm drilling leads to low bone heating.

Ø 3.5

Ø 4.5
Ø4

Ø5

COWELL® DIGITAL PRODUCTS


> Also used as a sinus lift tool (socket lift elevation).
2mm > Desired rpm : 20~30 rpm.

If the block bone is not removed


using the Trephine Drill, use dental
8
elevator or forceps to remove it. 6
4

0
Ø 3.5 Ø 4.0 Ø 4.5 Ø 5.0

Trephine Drill II Failed Fixture Removal

COWELL® EXPERT INSTRUMENTS


Diameter Ø 4.2 (Inner) Ø 4.7 (Inner) Ø 5.2 (Inner)
KFRT40 KFRT45 KFRT50
Bone Chip Extraction
Ø 4.5
Ø4

Ø5

14.5
14 Bone graft and Implant Placement
Implant Site Drill Final Drill
12
Socket Lift elevation
10
8

REGENERATIVE SOLUTION
0
Ø 4.2 Ø 4.7 Ø 5.2

COWELL®
Ø 5.0 Ø 5.5 Ø 6.0

244 COWELL® BMP Trephine Kit COWELL® BMP Trephine Kit 245
COWELLMEDI HISTORY
Atraumatic Extraction Kit [KAE001] 1. Extraction Drill
>G The Extraction Drill is composed of three types of Drills (Ø1.3 / Ø1.7 / Ø2.1) that can be selected according to the case.
>G Used for the immediate and effortless extraction of the root of the tooth with simple procedures.

Ø1.3 Drill Ø1.7 Drill 32


32
12
12

 Ø1.3  Ø1.7

REID
Code KAAD13 Code KARD17

Ø2.1 Drill 32
12

 Ø2.1

Code KAMD21

COWELL® IMPLANT SYSTEM


(1) Diversity
A root extraction can be done regardless of whether residual amount of root is large or small.
2. Extraction Screw
>G The Extraction Screw is fastened into the hole that was created by the Extraction Drill via the Screw method, and it is stably fixed
(2) Safety to the remaining root. It is composed of the Ø1.8 / Ø2.2 / Ø2.6 Screws that can be selected according to the Extraction Drill.
A root extraction without the risk of damaging adjacent teeth is possible using the Rest Plate, Elevator etc. >G The Ø1.8 Screw is used for vital root of which canal is not treated, after using the Ø1.7 Drill.

(3) Convenience
A very simple and convenient root extraction is possible, compared to the existing extraction method. Ø1.8 Screw

COWELL® DIGITAL PRODUCTS


35

(4) Reduced Procedure Time 25 10

The procedure time is reduced due to the simple procedure. M2.5 Ø1.8

Code KAAS16 * KAAS16X


Length 10 15
* Extra product
Composition

Extraction Drill & Screw Rest Plate Ø2.2 Screw 35

COWELL® EXPERT INSTRUMENTS


25 10

M2.5 Ø2.2




Torque Wrench Code KARS20 * KARS20X




Length 10 15
* Extra product

Post Driver Torque Head


Ø2.6 Screw
25
Ø 1.3 Drill Ø 1.7 Drill Ø 1.8 Screw Ø 2.2 Screw Ø 2.1 Drill Ø 2.6 Screw 15 10

M2.5 Ø2.6

REGENERATIVE SOLUTION
Elevator
Code KAMS25

COWELL®
246 Atraumatic Extraction Kit Atraumatic Extraction Kit 247
COWELLMEDI HISTORY
3. Post Driver 6. Elevator
>G After connecting the Post Driver to the Extraction Screw, turn the Torque Wrench in a clockwise direction in order to fix it to the >G The Elevator is used by connecting it with the Torque Head and extracting the root by applying force toward a distal or mesial
hole that was created by the Extraction Drill (recommended torque : 30 N.cm or more). direction.
20

13 169

Ø7.9 Ø4.5 30˚

Code KAPD13L

REID
* Connect to the Extraction Screw 5.5 Code KAE01

4. Rest Plate

COWELL® IMPLANT SYSTEM


>G The Rest Plate is connected between the Extraction Screw and the Torque Head. It protects the part with silicon that comes into
direct contact with the adjacent teeth in order to prevent teeth damage. How to Use
It also serves as a support for the Elevator and Torque Wrench.
1. Extraction Drill
>G One side is inclined at a 30° angle, so that it can act as a support depending on the removal direction.
Create a hole on the tooth to be extracted using the Extraction Drill.

37


Caution A

COWELL® DIGITAL PRODUCTS


14 - The Extraction Drill must follow the neural root canal during drilling.
NN
- Drill down to at least 10mm because extraction is possible even
if the Drill and Screw penetrate the root.

Rest Plate
5 KARP001B
Rest Plate Silicon Code
2. Extraction Screw
Connect the Extraction Screw to the Post Driver and fix it to the hole created by rotating it clockwise
(recommended torque: Min. 20 N.cm ~Max. 25 N.cm).

COWELL® EXPERT INSTRUMENTS


5. Torque Head
>G The Torque Head is connected to the Extraction Screw that is fixed in the tooth to be extracted.
It fixes the gap of the Rest Plate and it can be used with the Elevator.
> If the root to be extracted has both distal and mesial adjacent teeth, it will be extracted with the Torque Wrench
G CW
(recommended torque : 100 N.cm or less).
Caution B
11.5
- Drill to a depth of 10~12mm and insert the Extraction Screw at a depth of 10mm.
- Fix the Screw with 20~25 N.cm.

REGENERATIVE SOLUTION
Code KATH80

COWELL®
Connect Post Driver to the Extraction Screw.

248 Atraumatic Extraction Kit Atraumatic Extraction Kit 249


COWELLMEDI HISTORY
* Drilling Sequence

Root Canal Preparation


4. Torque Head
Connect the Torque Head to the Extraction Screw projected above the Rest Plate by rotating it clockwise.
#1 #2 #5

CW

REID
Canal filling

Identification of canal Gate drills

Atraumatic Extraction kit

COWELL® IMPLANT SYSTEM


Connect Torque Head to Screw

5. Torque Wrench
Under Under Extract the tooth by rotating the Torque Head clockwise using the Torque Wrench.





20 N.cm 20 N.cm

  CW

COWELL® DIGITAL PRODUCTS


Ø 1.3 Drill Ø 1.7 Drill Ø 1.8 Screw Ø 2.2 Screw Ø 2.1 Drill Ø 2.6 Screw

Caution C

- Fix the screw with a torque of 20~25 N.cm. If it is not applied, use a thicker Screw.
- The low torque force causes the Screw to fall out during the extraction, and the over torque force fractures tooth root.

COWELL® EXPERT INSTRUMENTS


3. Rest Plate Extraction Root
After removing the Post Driver, connect a Rest Plate to the Extraction Screw
by taking into account the adjacent teeth.

Caution D
- Extraction using the Torque Wrench is possible in a root with mesiodistal root.

REGENERATIVE SOLUTION
COWELL®
Rest Plate

250 Atraumatic Extraction Kit Atraumatic Extraction Kit 251


COWELLMEDI HISTORY
Caution E

- If there are adjacent teeth with 2 or higher swaying degrees, upward pulling or downward pressing should be applied using Direct Surgical Guide Kit [KDSG002]
the Elevator so that the teeth will not receive force during extraction.
>G Used for a flapless surgery.
>G Served as a guide for positioning the drill while measuring the thickness of the buccal bone, thereby preventing bone resorption
and reducing the burden on the patient.
>G Stable Drill positions can be guided to various cases by combining different surgical instruments
(E.g., Position Guide, Linker and Width Guide).

REID
COWELL® IMPLANT SYSTEM
Caution F
(1) Safety
- If there is an adjacent tooth projected to the mesiodistal root, it must be extracted using the Elevator. Safe operation is possible by measuring the thickness of the buccal bone in order to prevent buccal bone resorption.

(2) Reduced Pain


It is possible to minimize the burden on the patient by reducing the pain and swelling from a flapless surgery without going

COWELL® DIGITAL PRODUCTS


through the incision step that is carried out during the general implant surgery.

(3) Accuracy and Diversity


An accurate operation is possible depending on the bone width and implant diameter by combining the operation instruments
(E.g., Linker, Position Guide and Width Guide). It can be used for various cases, such as single, bridge etc.

1. Buccal Position Guide


> Use the depth pin positioned at the bottom of the guide according to the bone width and fixture diameter.
This will enable you to maintain the buccal bone thickness of the implant. The guide should be connected to the guide holder.

COWELL® EXPERT INSTRUMENTS


> The length can be distinguished with the O-ring color of the post.
> Be careful in using the depth pin because it is extremely sharp.

5.1mm

Sleeve

Post O-ring
6
8mm
Buccal Linker 2

REGENERATIVE SOLUTION
Depth Pin 1mm 2mm 3mm

COWELL®
Code KDBG01 Code KDBG02 Code KDBG03

252 Atraumatic Extraction Kit Direct Surgical Guide Kit 253


COWELLMEDI HISTORY
2mm 3mm
1mm
Caution C Select the 1, 2 or 3mm Buccal Position Guide depending on the alveolar bone width and implant
diameter to determine the buccal bone thickness.

Bucco-palatal bone width Fixture diameter

Black O-Ring

REID
Under 7mm bone width,
under Ø4.0mm fixture

Ø 3.0
Ø 4.0
1mm 1.5mm

COWELL® IMPLANT SYSTEM


Bucco-palatal bone width Fixture diameter
Caution A Please fix the depth pin of the Buccal Position Guide to the buccal bone surface 5mm below
the gingiva or the alveolar crest.

Red O-Ring
Bone Width 7~9mm,

Ø 4.0

Ø 4.0
5mm Ø4.0mm~Ø4.5mm fixture

2mm 2mm

COWELL® DIGITAL PRODUCTS


Bucco-palatal bone width Fixture diameter

Caution B In a defective buccal bone or a thin buccal bone due to tooth extraction, fix the depth pin of the
Buccal Position Guide to the surface 5mm below the gingival or the alveolar crest, from the Blue O-Ring

Ø 4.0

Ø 5.0
lingual or palatal side. Over 9mm Bone Width,
Ø5mm fixture

COWELL® EXPERT INSTRUMENTS


Buccal Bone Thin Wall 3mm 2.5mm
Defect

REGENERATIVE SOLUTION
COWELL®
254 Direct Surgical Guide Kit Direct Surgical Guide Kit 255
COWELLMEDI HISTORY
2. Width Guide
> Select the 7, 8, 9, or 10mm-width guide according to the implant crown diameter, mount it on the
How to use according to the mesiodistal dimension-2
Buccal Position Guide, and Drill the center of the implant (the size is distinguished by color). (Use of the combined Width Guides)

7mm
8mm
9mm
10mm

REID
Ø7 Ø8 Ø9 Ø10

Code KDWG07 Code KDWG08 Code KDWG09 Code KDWG10

PF
/CZKNNC .CV+PEKUQT UV 2TGOQNCT
2TGOQNCT
Mesiodistal 7.3 7.7 7.3
dimension

COWELL® IMPLANT SYSTEM


The width guide is used by connecting it with the sleeve of the Buccal Position Guide.

Width Guide

Sleeve

COWELL® DIGITAL PRODUCTS


PF
/CPFKDNG %CPKPG UV 2TGOQNCT
2TGOQNCT

Buccal Position Guide Mesiodistal 7.2 7.3 7.3


dimension

COWELL® EXPERT INSTRUMENTS


How to use according to the mesiodistal dimension-1
5.1mm
(Use of the Buccal Position Guide)
Buccal Position Guide
Mesiodistal Dimension

%GPVTCN .CVGTCN
/CPFKDNG KPEKUQT KPEKUQT
Mesiodistal
dimension 5.4 6.0
%GPVTCN UV PF
/CZKNNC %CPKPG /CPFKDNG UV /QNCT PF /QNCT
+PEKUQT /QNCT /QNCT
Mesiodistal Mesiodistal 11 10

REGENERATIVE SOLUTION
9.2 8.3 10.5 9.5 dimension
dimension

COWELL®
256 Direct Surgical Guide Kit Direct Surgical Guide Kit 257
COWELLMEDI HISTORY
3. Position Guide
> Guide the Drill position according to the distance between implant centerlines (7, 9, 11mm). Application of the 9mm Position Guide Application of the 11mm Position Guide
(when the mesiodistal distance between (when the mesiodistal distance between
The device consists of three gaps : 3mm, 5mm, and 7mm from the Ø4mm fixture interface.
the two missing teeth is at least 16mm) the two missing teeth is at least 18mm)
> In continuous implants, select the 7, 9, or 11mm Position Guide according to the crown size,
and mount it on the Buccal Position Guide to drill.

7
5 6
6
6 6
5

REID
Ø2.15
7
Maxilla Mandible Mandible
Maxilla

12

4. Linker
Ø 4.0

Ø 4.0

Ø 4.0

COWELL® IMPLANT SYSTEM


10
3mm 5mm 7mm > When you perform prosthesis with a bridge in a continuous implant, connect the 11mm Linker to the position

Ø2.15
guide and the Buccal Position Guide to drill.
9mm 11mm
7mm
Code K3PP07 Code K3PP09 Code K3PP11

Code K3L11
* The Position Guide must be used in combination with the Buccal Position Guide and linker. 11mm
It cannot guide the Drill position accurately when used alone.

11mm

COWELL® DIGITAL PRODUCTS


11mm

Application of the 7mm Position Guide Assembly


(when the mesiodistal distance between the two missing teeth is at least 14mm)

2
3 3
4

COWELL® EXPERT INSTRUMENTS


Linker Sleeve
4 Linker
Position Guide
5

5
4
Buccal Position Guide
Maxilla Mandible
ⴘ Position Guide + Linker ⴙ Position Guide + Linker + Buccal Position Guide

ⴘ The Linker is connected to the Position Guide by setting the linker sleeve in a downward position.

REGENERATIVE SOLUTION
ⴙ After connecting the Linker by setting the sleeve of the Buccal Position Guide in a downward position,

COWELL®
it can be used by adjusting it according to the mesiodistal distance.

258 Direct Surgical Guide Kit Direct Surgical Guide Kit 259
COWELLMEDI HISTORY
5. Point / Crestal Cutter Drill Buccal Position Guide Assembly
> A hole is created on the cortical bone in order to facilitate the Initial Drill.

> The gingiva residue is removed while flattening the uneven alveolar bone surface.
Buccal Position Guide

30.1

Ø2.2 Ø3.95

Crestal Cutter Point Drill

REID
Code K3CPD01 Guide Handle
Drill
* After connecting the guide handle to the
buccal position guide, fix it at the site where
the implant will be placed and insert the
Guide Drill into the hole inside the Sleeve.

COWELL® IMPLANT SYSTEM


6. Guide Handle Drilling Sequence (Flapless Surgery)
> The Guide Handle guides the position and direction by connecting it with the Buccal Position Guide.

Code KSRGH01

COWELL® DIGITAL PRODUCTS


Angulation of Guide assembly


Crestal Cutter
1. Mesio-distal angle: parallel with adjacent tooth Guide Drill
2. Bucco-lingual angle

COWELL® EXPERT INSTRUMENTS


Anterior : Match incisal edge Premolars: Match the buccal cusp Posterior: Match the centerline

* The angle of the guide can be predicted according to the shape of the tooth. Fixture Installation Final Drill

* Form basic holes with a crystal cutter. Then, select a drilling sequence according to the implant diameter.

REGENERATIVE SOLUTION
COWELL®
260 Direct Surgical Guide Kit Direct Surgical Guide Kit 261
COWELLMEDI HISTORY
AO4 Surgical Stent [KDSS001]
> Guide the position of Implant and Drill.

Eligible for
> A toothless patient.
70mm > Patient who do not want long-period of surgery.
> Patients suffering from adult diseases such as hypertension and diabetes.

REID
> Patients who need precise implant treatment.

10mm

Instruction
T : 0.4mm

COWELL® IMPLANT SYSTEM


7 7 10mm
Place the • Make an incision for flap lift.
Ø2 AO4 • Place the AO4 Surgical Stent using Ø2mm Twist Drill.
* it is needed to check the position of mental foramen.
Surgical
Stent

Place the

COWELL® DIGITAL PRODUCTS


INNO • Drill with reference to the angled line and place the fixture.
Fixture

Place the • After placing the INNO fixture,


Multi S&A connect the Multi S&A Abutment according to the site.
* Posterior site : Place the Multi A abutment (30°) with 30 N.cm torque force.
Abutment * Anterior site : Place the Multi A abutment (15°) or the Multi S abutment with

COWELL® EXPERT INSTRUMENTS


15 N.cm torque force (it is possible to allow emergence of the prosthetic screw).
Characteristic
or
> Guide the position of the implant and drill during implant placement.
> It improves the stability and accuracy in surgery, and it can shorten the time.
> By preventing the loss of healthy gums as much as possible, pre-fabricated prostheses can be placed immediately after
surgery without the need for gum restoration. Placement • After placing the INNO Fixture,
> Angled line allows more precise and predictable surgery. Lock connect Lock Abutment according to the site
* If implant placement at an angle is not appropriate or not desired,
Abutment using the INNO Sub. Short Implant is highly recommended.

REGENERATIVE SOLUTION
COWELL®
262 AO4 Surgical Stent AO4 Surgical Stent 263
COWELLMEDI HISTORY
2. SPECIFICATION
Volume-up™ Guide System Volume-up™ Gauge
> Devised for preventing food penetration and forming natural cervical area by restoring contracted For the Ø6.5~Ø8.5mm
buccal alveolar bone & gingiva to the original shape and width. Healing Abutment

Ø10.5

REID
1. CONCEPT Ø9.5
For the Ø3.5~Ø5.5mm
Healing Abutment
• Peri-implant inflammations represent serious diseases after dental implant treatment, which affect both the Ø8.5
surr
surrounding
rounding hard and soft
rounding sof
sofft tissue.
t

Ø6.5 Line
Ø5.5 Line
Ø7.5 Line
Ø4.5 Line
Ø8.5 Line

COWELL® IMPLANT SYSTEM


Ø3.5 Line

Ø5
* Actual diameter is 2mm larger than the diameter marked on the Volume-Up™ Gauge
Code KHSG01
(E.g. Ø6.5 marked on the Gauge is actually Ø8.5). Ø6
Ø7
To achieve long term success of implant without complications like peri-implantitis, right position of fixture with
min. 2mm of buccal bone width for buccal gingival regeneration and alveolar bone regeneration at min. 3mm lower
> Used to guide the position of implant placement and to guide the election of the Healing Abutment dimensions in order
position to maintain gingival height is extremely essential.
to keep the cervical portion of the implant prosthesis at the natural tooth width.
> Used with the Volume-up™Parallel Pin for multiple units or bridge.
> Used with Point Drill (Ø2.1mm or less).

COWELL® DIGITAL PRODUCTS


> Laser marking identifiable from any position.
Min. 2mm of buccal bone regeneration to maintain Alveolar bone regeneration at minimum 3mm
having buccal gingiva. lower position to maintain gingival height. ୔ For the selection of the Healing Abutment, refer the pages 34, 63, 81 & 100.
(Int J Periodontics Restorative Dent 2005) (Clin Oral Implants Res 2000;11: 1–11.)

2mm Volume-up™ Parallel Pin


13 7
> Used for bridge or multiple units with the Volume-up™ Gauge.
3mm D Ø2.5 > For bridge or multiple units.
> For Ø3.5, Ø4.5 and Ø5.5, place the fixture and use the Healing Abutment instead

COWELL® EXPERT INSTRUMENTS


of the Volume-up™ Parallel Pin.

Breakaway Stopper
Prevents breakaway from intraoral cavity by connection silk.

Diameter Marking
Marked and Colored by diameter.

The Volume-up™ Guide System helps place implant in the right position according to 2 abovementioned clinical
factors and helps select right dimension of the Healing Abutment to be used as a scaffold while gingival forming. Gingival Height Marking
1~4mm of cuff marking.
1mm
1mm
1mm

REGENERATIVE SOLUTION
Ø6.5 Ø7.5 Ø8.5
1mm
Pin KVPP65 KVPP75 KVPP85
Inserted into the hole formed by the Point Drill.

COWELL®
264 Volume-up™ Guide System Volume-up™ Guide System 265
COWELLMEDI HISTORY
3. PROCEDURE 4. CLINICAL CASE

I. Single Implant

REID
Set the Volume-up™ Gauge on the Position the Point Drill in the drill
implant site according to the diameter insertion groove of the Volume-up™
line marked on the Volume Up™ Gauge. Gauge.
Preoperative view of the The Volume-up™ Gauge was The Ø8.5 Volume-up™ Parallel

COWELL® IMPLANT SYSTEM


1mm 1mm
healed ridge. set to the 8.5 line and point Pin was inserted to the hole
drilling was carried out. formed by point drilling
and point drilling was done
at the next site guided by
the Volume-up™ Gauge.

Drill and place implant in accordance If implant placement torque is equal


with the manufacturer’s implantation to or over 20~30 N.cm, connect the
sequence. Healing Abutment. If not, connect

COWELL® DIGITAL PRODUCTS


the Cover Screw and do primary
closure.

II. Multiple Implants & Bridge

COWELL® EXPERT INSTRUMENTS


The Ø8.5 Healing Abutments After 4 weeks, the contracted
were placed after initial & buccal alveolar bone & gingiva
finial drilling and fixture to the natural shape and
placement and bone grafting, width were restored.
and the site was sutured. Which will allow esthetically
Set the Volume-up™ Gauge and Insert the Volume-up™ Parallel Carry out the same as the and functionally great prosthesis
position the Point Drill. Pin into the hole formed after previous step. fabrication preventing food
point drilling. permeation.

REGENERATIVE SOLUTION
* For Healing Abutment selection, refer to the page 33.

COWELL®
266 Volume-up™ Guide System Volume-up™ Guide System 267
COWELL® REGENERATIVE SOLUTION COWELL®
REGENERATIVE
Inspire confidence through a comprehensive approach SOLUTION

COWELL® BMP & INNO GF Kit INNO-CaP


The world’s first E.rhBMP-2, (E.Coli derived Recombinant Osteoconductive synthetic bone graft material consisting
MegaDerm™ Plus Human Bone Morphogenetic Protein type 2), of CaP is completely resorpted and progressively replaced
The acellular dermal matrix can carry out as a growth factor that induces bone and cartilage formation. by vital bone in the healing period.
the functional blocks of the membrane due to It is a retinoid mediator that plays a key role in osteoblast
its long absorption period (soft tissue penetration protection) differentiation.
and is the first in the world with the basement membrane DiaDerm® M
layer removed to maximize the transplant engraftment rate. Biodegradable atelocollagen membrane is used for
GTR & GBR operation. The product, made from high purity
atelocollagen, has high biocompatibility, mechanical strength
and resistance to enzymatic degradation and flexibility.

INNO OSS™ Allo


Allograft composed of 50% of cortical
and the other 50% of cancellous.
FDBA has been proven out its efficiency BOSS® System
and safety by the highest-level
New concept for vertical and lateral bone augmentation. DiaBone
pharmacological standards of AATB and
The product is composed of tenting abutment, screw and
is being a global standard of allograft. InnoGenic™ Non-resorbable membranes A xenograft is perfectly fused to natural
cover as well as guide post. Using the system with Wifi-Mesh is
highly recommended. The products consisting of Titanium reinforced PTFE membrane (Wifi-Mesh), human bone. Diabone has fast blood
PTFE membrane (PTFE-Mesh) and Titanium mesh (Ti-Mesh) penetration by giving great hydrophilicity
are non-resorbable membranes to be applied over intraoral and 3D dimensional structure which allow
defects, especially, tooth extraction and bone augmented sites. optimal cell attachment and blood
absorption.
COWELLMEDI HISTORY
4. Mechanism of Action of COWELL BMP
COWELL® BMP Osteoinductive Bone Graft
rhBMP-2 + BCP
A. Migration of Cells with lamellipodia

1. Composition of COWELL® BMP A


filopodium
lamellipodium
A. Filopodial extensions
Ror2 Brld
cdc42 brll
Myo-x LIMK
•G COWELL® BMP is bone graft material based on the E.rhBMP-2 (E.Coli derived Recombinant Human Bone
B adhesions
Morphogenetic Protein type 2), developed for the first time in the world. COWELL® BMP is supported with B. Cell protrusion
10 years of clinical data and over 40 studies. extracellalar space P13K Rho-
Intergrins GTPase
stationary cell actin filaments FAK
•G BCP as a carrier allows maintenance of space.

REID
microtubule
microtubule C. Nuclear effectors
GTP GDP organizing center R-smad MAPK
2. Features of COWELL® BMP Rho-GDP Rho-GTP C nucleus
I-smad p38

LIMK1
•G Primary closure for soft tissue regeneration is not required. Cofilin
D adhesions D. Retraction
Intergrins FAK
• Regenerates adherent gingiva.
G

Actin remodeling cytoplasm polarized cell


migrating cell
•G Simplifies challenging bone grafting and soft tissue regeneration.

COWELL® IMPLANT SYSTEM


•G Acts directly on stem cells.
•G Induces bone regeneration without infection in extraction socket.

•G Contains 1mg of bone morphogenic protein per 1g of the particle.


(1g of autologous bone contains 2ng of bone morphogenic protein) B. Cellular mechanisms
A : BISC BMP-2 B : PFC
BRII BRI
3. Application
A. Orthopedics

COWELL® DIGITAL PRODUCTS


DRM Clsthrin-
coated
Bone grafts Injection Device pit •G BMP-2 adheres to the membrane of
stem cell and induces expression of
•G Fractures : Tibia, Radius, Ulna. •G Lengthening : Distraction osteogenesis. genes of nucleus. Then, BMP-2 migrates
•G Spine Fusion (Degenerative Disc Disease) : •G Osteoporosis : Hip joint fracture. non-transcriptional to recipient site.
responses early
endosome
Interbody cage, Posteolateral. • Bone Defect : Bone cyst.
G •G BMP-2 growth factor, Twist-2
•G Bone Fusion : Foot/shoulder revision. cytoskeletal transcriptional factor, and VEGF growth
rearrangements
factor synthesize and secrete
caveosome
endogenous growth factor.

crosstalk •G Proliferation of osteoblast of osteocyte,

COWELL® EXPERT INSTRUMENTS


non-Smad & Smad
pathway fine tuning pathway R-Smad1/5/8 and proliferation of fibroblast in dermis
B. Dentistry C. Dermatology and keratinocyte of the skin.
p38 co-smad4
•G Twist-2 transcriptional factor induces
Bone grafts Soft Tissue grafts ERK miRNA
P13K tissue regeneration in osseous tissue
and adherent gingival area.
•G Severely resorbed alveolar ridges. •G Damaged skin regeneration.
•G Tooth extraction socket. •G Diabetes ulcer.
•G Alveolar bone loss.
•G Maxillary sinus bone loss.
•G Bone-inductive implant : Coated implant.
•G Maxillofacial reconstruction. non-smad-responsive genes smad-responsive genes

REGENERATIVE SOLUTION
COWELL®
270 COWELL® BMP COWELL® BMP 271
COWELLMEDI HISTORY
5. Product Type COWELL® BMP Plus (Two vials)

COWELL® BMP (One vial)


BMP Powder BCP Particle

BMP Coated
BCP Particle
BMP + BCP
BMP Powder

REID
BMP BMP Powder
+ BMP Coated BCP Particle

•G Dose and particle


le size of the COWELL® BMP Plus.
Plus

•G Dose and particle size of the COWELL® BMP BMP 0.1mg BMP 0.25mg

Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size

COWELL® IMPLANT SYSTEM


EBB0125 0.1mg 0.25g 0.41~1.0mm EBB2525 0.25mg 0.25g 0.41~1.0mm
EBB0105 0.1mg 0.5g 0.41~1.0mm EBB2505 0.25mg 0.5g 0.41~1.0mm
EBB1110 0.1mg 1g 0.41~1.0mm EBB1125 0.25mg 1g 0.41~1.0mm
EBB1220 0.1mg 2g 0.41~1.0mm EBB1225 0.25mg 2g 0.41~1.0mm

BMP 0.5mg BMP 1mg

Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size

EBB0525 0.5mg 0.25g 0.41~1.0mm EBB1025 1mg 0.25g 0.41~1.0mm

COWELL® DIGITAL PRODUCTS


EBB0505 0.5mg 0.5g 0.41~1.0mm EBB1050 1mg 0.5g 0.41~1.0mm
EBB1150 0.5mg 1g 0.41~1.0mm EBB1011 1mg 1g 0.41~1.0mm
Product Code Particle Size Product Code Particle Size Product Code Particle Size
EBB1250 0.5mg 2g 0.41~1.0mm EBB1012 1mg 2g 0.41~1.0mm
BB1010 0.41~1.0mm BB1025 0.41~1.0mm BB1050 0.41~1.0mm
୔ A vial of 0.1g can be used for less than one extraction socket, while 0.25g/0.5g can be used for maxillary sinus or for the wide bone defect area.
BMP 2mg

Product Code BMP Dose Particle Dose Particle Size

EBB2025 2mg 0.25g 0.41~1.0mm


EBB2050 2mg 0.5g 0.41~1.0mm

COWELL® EXPERT INSTRUMENTS


EBB2011 2mg 1g 0.41~1.0mm
EBB2012 2mg 2g 0.41~1.0mm

REGENERATIVE SOLUTION
COWELL®
272 COWELL® BMP COWELL® BMP 273
COWELLMEDI HISTORY
INNO GF Kit (Two vials + Saline Solution + Syringe) 6. User Guide COWELL® BMP
A. Method*

BMP Powder BCP Particle Saline Solution


& Syringe

BMP + BCP +

REID
•G Dose and particle size of the INNO
I GF Kit.
a. Transfer BCP graft material (Vial *). b. Inject distilled water into vial ** with lyophilized
BMP 0.1mg BMP 0.25mg rhBMP-2 power in it and mix with the powder.

Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size

COWELL® IMPLANT SYSTEM


IBB0125 0.1mg 0.25g 0.41~1.0mm IBB2525 0.25mg 0.25g 0.41~1.0mm
IBB0105 0.1mg 0.5g 0.41~1.0mm IBB2505 0.25mg 0.5g 0.41~1.0mm
IBB1110 0.1mg 1g 0.41~1.0mm IBB1125 0.25mg 1g 0.41~1.0mm
IBB1220 0.1mg 2g 0.41~1.0mm IBB1225 0.25mg 2g 0.41~1.0mm

BMP 0.5mg BMP 1mg c. Mix BMP solution with BCP or plus autogenic d. Cover the defect area using a barrier membrane or
/ allograft and apply into the recipient site. suture natural soft tissue without membrane.
Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size

IBB0525 0.5mg 0.25g 0.41~1.0mm IBB1025 1mg 0.25g 0.41~1.0mm


IBB0505 0.5mg 0.5g 0.41~1.0mm IBB1050 1mg 0.5g 0.41~1.0mm B. Method**

COWELL® DIGITAL PRODUCTS


IBB1150 0.5mg 1g 0.41~1.0mm IBB1011 1mg 1g 0.41~1.0mm
IBB1250 0.5mg 2g 0.41~1.0mm IBB1012 1mg 2g 0.41~1.0mm

BMP 2mg

Product Code BMP Dose Particle Dose Particle Size

IBB2025 2mg 0.25g 0.41~1.0mm


IBB2050 2mg 0.5g 0.41~1.0mm
IBB2011 2mg 1g 0.41~1.0mm

COWELL® EXPERT INSTRUMENTS


IBB2012 2mg 2g 0.41~1.0mm
a. Transfer BCP graft material b. Apply BCP into the recipient site and cover the c. Inject distilled water into
(Vial *) into a container. defect area using a barrier membrane or suture lyophilized rhBMP-2 powder
natural soft tissue without membrane. (vial **).

REGENERATIVE SOLUTION
d. Mix rhBMP-2 with distilled water e. Aspirate the mixture using a syringe. f. Inject BMP solution through

COWELL®
(saline solution) and wait for soft tissue until needle
10 to 15 seconds before using. of syringe reaches bone.

274 COWELL® BMP COWELL® BMP 275


COWELLMEDI HISTORY
C. Method *** 7. Study Result on COWELL® BMP
In Vivo Study
Control group BMP group

At surgery

4 weeks

REID
after surgery

8 weeks
after surgery

a. Inject distilled water into vial **with lyophilized b. Aspirate the mixture using a syringe.
rhBMP-2 power in it and mix with the powder. Jung-Bo Huh, et al., Alveolar ridge augmentation using anodized implants coated with Escherichia coli-derived recombinant human bone
morphogenetic protein 2 (Beagle dog).

COWELL® IMPLANT SYSTEM


- Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011.

Histologic Findings : Tissue specimen collected approximately four months


after the maxillary sinus grafting (human)
X400 •G New bone was formed around the graft material.
•G No inflammatory reaction was observed in connective tissue.
c. Hydrate BMP-2 solution into membrane. d. Apply BMP-2 solution socked membrane X200
to damaged site. •G Proliferation of collagen fiber was observed.
•G Proliferation of fibrocyte was observed.

COWELL® DIGITAL PRODUCTS


•G Osteoblast was observed on the surface of newly formed bone.

Dose of distilled water to make the mixture (BMP-2 Solution)

BMP Dose Distilled Water Dose BMP Dose Distilled Water Dose
8. Clinical Data of COWELL® BMP
•G Vertical height of surrounding bone was compared three months after grafting in extraction socket.
0.1mg 0.1ml 2mg 1.6ml •G The study was conducted at Seoul National University Bundang Hospital, Yonsei University Dental Hospital, and Korea University Guro Hospital.
0.25mg 0.2ml 5mg 4ml
Group Average SD 95%CI †P value
0.5mg 0.4ml 10mg 8ml

COWELL® EXPERT INSTRUMENTS


Control -1.087 1.413 (-1.565, -0.609)
1mg 0.8ml 20mg 16ml Height 0.0006**
Experiment -0.059 0.960 (-0.384, 0.266)
Control 1.405 1.753 (0.812, 1.998)
Width at 75% ESL 0.346
Experiment 1.863 2.310 (1.081, 2.644)
Control 0.542 1.157 (0.15, 0.934)
Width at 50% ESL 0.016*
Experiment 1.239 1.249 (0.816, 1.662)
Control 0.006 1.149 (-0.383, 0.395)
Width at 25% ESL <0.0001**
Experiment 1.279 1.387 (0.81, 1.749)

ESL : Extraction Socket Level *:P<.05, **:P<.01, †: Student t-test

REGENERATIVE SOLUTION
Jung-Bo Huh, et al., Multicenter, randomized clinical trial on the efficacy and safety of Escherichia-coli-derived rhBMP-2
with β-Tricalcium phosphate and hydroxyapatite in human extraction sockets.

COWELL®
- J Adv Prosthodont 2011;4 -134.

276 COWELL® BMP COWELL® BMP 277


COWELLMEDI HISTORY
INNO-CaP Calcium Phosphate , Synthetic Bone Graft A porosity for new bone ingrowth
•G The porosity promotes ingrowth of osteoblast, osteoclast and growth factors.

Osteoconductive resorbable synthetic bone graft material


Particle surface SEM image
•G INNO-CaP is a osteoconductive synthetic resorbable bone graft material consisting of Calcium Phosphate.
•G INNO-CaP is completely resorpted and progressively replaced by normal-structured bone in the healing period.

Excellent Biocompatibility and Conductivity

REID
•G The characteristic biocompatibility and conductivity of the INNO-CaP represent the most safety.

Cell culture SEM images (14 days)

X50 X100 X500

COWELL® IMPLANT SYSTEM


Indications
Sinus graft surgery
•G For sinus graft, INNO-CaP is used alone or in combination with the other graft materials.
•G Various healing period according to residual bone height.

residual bone height less than 1mm 2~4mm more than 4 mm


post operation post operation
implant placement simultaneous placement
9~12 months 6 months

COWELL® DIGITAL PRODUCTS


X1,000 X1,000
GBR (Guided Bone Regeneration)
•G Minimize the amount of autogenous bone.
•G Sub-graft materials.
•G Vertical and lateral augmentation.
•G Using with the COWELL® BMP is highly recommended.

Dose and Particle Size

COWELL® EXPERT INSTRUMENTS


Product Code Particle Size Particle Dose

IG1025 0.25g
IG1050 0.5g
0.4~1.0mm
IG1001 1g
IG1002 2g
IG1425 0.25g
IG1450 0.5g
1.0~1.4mm

REGENERATIVE SOLUTION
IG1401 1g
IG1402 2g

COWELL®
278 INNO-CaP INNO-CaP 279
COWELLMEDI HISTORY
INNO OSS™ Allo Allograft
FDBA, Cortical 50% Cancellous 50% DiaBONE Bovine Bone Substitute

A Bone 100% fused to Natural Human Bone


Product Features •G Fast blood penetration.
•G Great hydrophilicity.
•G This product is made up of human tissue from trusted donors
whose gender, age, and medical history were checked to •G 3D mention structure.
ensure that their tissue could be used safely. •G Easy to handle.

REID
•G It is an ideal combination of 50% cortical powder and 50% •G Maximizes bone fusion.
cancellous powder for bone induction. •G Mutually connected porous structure.
• The 50% cortical powder maintains the space of the transplanted area during the new bone formation due to the delayed
G
•G Optimal cell attachment and blood absorption.
absorption rate. [OsteoConduction] •G Stimulates activity of osteoclast and osteoblast.
•G 50% cancellous powder is rich in minerals and collagen that promote cell adhesion, bone remodeling, and vascular re-formation.
[OsteoInduction]

COWELL® IMPLANT SYSTEM


•G To prevent cross-infection by a different donor, the process is done by a single donor.
•G Under the higher-level pharmacological standards (medical criteria) of the American Association of Tissue Banks (AATB),
we sampled, processed and distributed the allograft tissue.
•G We recommend use of this product with the COWELL® BMP. Human bone structure Dia bone structure (x50) Dia bone structure (x1,500) Hydrophilicity 1 Hydrophilicity 2

SEM Image Dose and Particle Size


Safe & Trustable Material
Product Code Particle Size Particle Dose •G Made of 100% bovine bone.
•G Cleansing over 30 times to perfectly remove organic substances.

COWELL® DIGITAL PRODUCTS


OSS3P 0.3~0.8mm 0.3cc
•G Firmed bone formation as highly dense.
OSS6P 0.3~0.8mm 0.6cc
•G 100% pure HA & 99.73% of bone crystallization.
Cortical 50% Cancellous 50%

COWELL® EXPERT INSTRUMENTS


Raw material Graft test 1 Graft test 2

Method of Use (New bone formation clearly observed around grafted bone site)

Volume and Particle Size


Product Code Particle Size Volume Product Code Particle Size Volume

G2015 0.25~1.0mm 0.15g G5015 1.0~2.0mm 0.15g


G2025 0.25~1.0mm 0.25g G5025 1.0~2.0mm 0.25g
G2050 0.25~1.0mm 0.5g G5050 1.0~2.0mm 0.5g

REGENERATIVE SOLUTION
Turn and pull G2100 0.25~1.0mm 1g G5100 1.0~2.0mm 1g
Remove the syringe’s Hydrate it in saline Graft it in the
out the syringe
rubber cap. solution. desired area.

COWELL®
G2200 0.25~1.0mm 2g G5200 1.0~2.0mm 2g
cap to remove it.

280 INNO OSS™ Allo DiaBONE 281


COWELLMEDI HISTORY
MEGA DERM™ PLUS Acellular Dermal Matrix

MEGA DERM PLUS three-dimensional structure of the dermis

Product Features
•G This product can carry out the functional blocks of the membrane
ane
(soft tissue penetration protection) due to its long absorption period,

REID
and has excellent manipulability.
•G Unlike other imported complete products, this product is produced
uced
under the stringent standards of the FDA in Korea. LW Y ⽅ LW Y ⽅

•G The world's first E-Beam sterilization can induce safe and prompt
pt
engraftment. Normal skin 0(*$'(503/86 Other product

•G E-Beam is safe and can be effectively sterilized without destroying


ing the collagen tissue structure.
structure
•G This product is the first in the world with the basement membrane layer removed (patent pending) to maximize the transplant

COWELL® IMPLANT SYSTEM


engraftment rate.
•G This shows the high engraftment rate after the transplant by maximizing the influx of fibroblasts and/or the neovascularization.
The world's first 'E-Beam' sterilization that does not destroy
(Patent Application No. 10-2012-0026616) the collagen structure

[Before
Application sterilization]

•G Mucogingival defect.
•G Soft tissue formation around the implant area.

COWELL® DIGITAL PRODUCTS


•G Wide perforation in the Schneiderian membrane.
[After
sterilization]
EO Gas Gamma Ray E-Beam
SEM Images (These have kept the collagen structure after the E-Beam sterilization.)
A B C D

Other product 0(*$'(503/86

COWELL® EXPERT INSTRUMENTS


A. SEM (x200) B. SEM (x20,000) C. TEM (Transverse section) D. TEM (Cross section) Bacteria removal
Normal collagen
Destroyed collagen
Specifications EO chemical residue
Product Code Size Thickness

D1520P 15x20mm 0.5~0.7mm

D1525P 15x25mm 0.5~0.7mm

REGENERATIVE SOLUTION
COWELL®
282 MEGA DERM™ PLUS MEGA DERM™ PLUS 283
COWELLMEDI HISTORY
Diaderm® M Biodegradable Atelocollagen Membrane BOSS® BMP bone graft and Open Sheet System

GTR(Guided Tissue Regeneration)


Advantages
GBR(Guided Bone Regeneration) membrane
• Maintains the width and height of adherent gingiva.
•G Diaderm® is a dental membrane used for GTR (Guided Tissue Regeneration) and GBR (Guided Bone Regeneration) operation.
• Offers superb mechanical support.
•G Diaderm® helps restoration of alveolar bone and protect operation site from infiltration of an epithelial cell and exterior circumstances.

REID
• Easy to customize for the application of various cases.
•G Diaderm® made from high purity atelocollagen has high biocompatibility, mechanical strength, resistance to enzymatic degradation • Primary closure may be not required.
and flexibility. • The result may come out the best using osteoinductive material.

Product Features Introduction

COWELL® IMPLANT SYSTEM


•G High biocompatibility.
•G Induces restoration of tissue. Type 1 (BOSS® Abutment ) : Placement of implant in the extraction socket
•G Closes wound site completely.
•G Sustains space for bone reproduction.
on.
•G Easy to handle and operate.

COWELL® DIGITAL PRODUCTS


Resistance against enzymatic degradation
•G Diaderm® has higher resistance to enzymatic-degradation compared to products from other manufacturers.

Enzymatic degradation test (Trypsin)


Remaining Weight (%)

80
• When residual bone is not sufficient for implant placement, the BOSS® can induce both vertical and horizontal
67.9% augmentation upon implant placement.
60
• The BOSS® consists of abutment and guide for maintaining the space of regeneration of osseous and soft tissues.

COWELL® EXPERT INSTRUMENTS


40

20

0
G company Z company B company

Storage and Shelf Life Specifications

REGENERATIVE SOLUTION
•G Store at 1-30°C
Product Code Size
•G Shelf Life : 3 years from the date of manufacture
AS-007020 15X30mm

COWELL®
284 DIA-DERM® M BOSS® 285
COWELLMEDI HISTORY
A. Structure of the product Type 2 (BOSS® Screw) : Placement of implant in cases other than the extraction socket

Body Healing(Cover) Temporary Post (Guide)


Hex 0.9 Hex 0.9 Hex 0.9

Diameter Ø2.0
Diameter Ø4.0 Diameter Ø4.0

0.8
Cuff 3

7.7
Length

REID
vertical fixation horizontal fixation

Product Code Length Cuff Product Code Product Code

BSSB420 7.7 2 BSSH001 BSST001


• When implant cannot be placed or when implant is to be placed after two sessions of bone regeneration procedure.
BSSB430 8.7 3 • Consists of screw that can be fixed onto osseous tissue and guide.
BSSB440 9.7 4 • Protects bone graft material against external force using the InnoGenic™ Wif i-Mesh / PTFE-Mesh / Ti-Mesh.

The body is connected to the fixture The interface between body and Before covering, the InnoGenic™ Wif i-Mesh /

COWELL® IMPLANT SYSTEM


maintaining the space for regeneration the InnoGenic™ Wif i-Mesh / PTFE-Mesh / PTFE-Mesh / Ti-Mesh is shaped and the A. Structure of the product
of soft tissue. Ti-Mesh is fixed. intraoral position of those is determined.

Screw Screw Driver Healing(Cover) Temporary Post


(Guide)
Hex 0.9
Hex 0.9
B. User Guide

Diameter Ø2.0

3 Diameter Ø3.2

27
3.2

COWELL® DIGITAL PRODUCTS


Length 9.2

Product Code Length Product Code Product Code

Cuff: The height is identical BSSS2306 6 2BSSC001 2BSSG001


to that of neighboring gingiva. BSSS2310 10
The interface between Before covering, the InnoGenic™
Product Code
Placement of implant. Adjust the height identical to Fill the blood-soaked bone graft Modify the shape of the The product fixes onto KBSD01
Screw and the Wif i-Mesh / PTFE-Mesh / Ti-Mesh
that of neighboring gingiva. material in the defective area. InnoGenic™ Wif i-Mesh / osseous tissue using InnoGenic™ Wif i-Mesh / is shaped and the intraoral
Connect using the 0.9 Hex driver. PTFE-Mesh / Ti-Mesh to a dedicated Screw Driver. PTFE-Mesh / Ti-Mesh is fixed. position of those is determined.
prevent the bone graft
material from escaping

COWELL® EXPERT INSTRUMENTS


into the oral cavity. B. User Guide
• Select the Screw with an appropriate width and height and then fix using a dedicated Screw Driver.
• Fill the blood-soaked bone graft material into the defective bone.
• Modify the shape of the InnoGenic™ Wif i-Mesh / PTFE-Mesh / Ti-Mesh to prevent the bone graft material from escaping into the oral cavity.
• Connect the Screw and Guide, place the InnoGenic™ Wif i-Mesh / PTFE-Mesh / Ti-Mesh and then fix using the Cover.
• Suture the Cover without additional incision (if the InnoGenic™ Wif i-Mesh is used, primary closer is required). The result shall be much more
predictable and better if rhBMP-2 solution made by the COWELL® BMP is injected via gingiva into osseous tissue in the bottom.

Connect abutment body to Fix the InnoGenic™ Wif i-Mesh/ Suture the cover without additional incision
the guide and place the PTFE-Mesh / Ti-Mesh using the cover. (if the InnoGenic™ Wif i-Mesh is used, primary closer is
Instrument

REGENERATIVE SOLUTION
Product Code Size
InnoGenic™ Wif i-Mesh / required). The result shall be much more
PTFE-Mesh / Ti-Mesh. predictable and better if rhBMP-2 solution made by 0.9 Hex Driver KHD0915 15

COWELL®
KHD0921 21
the COWELL® BMP is injected via gingiva into osseous • For connecting the BOSS® Abutment and Cover. KHD0927 27
tissue in the bottom.

286 BOSS® BOSS® 287


COWELLMEDI HISTORY
Clinical Case using the Wifi-Mesh

InnoGenic™ Non-resorbable Membrane


InnoGenic™ Wifi-Mesh and InnoGenic™ PTFE-Mesh • Periodontitis with local
osteomyelitis of #45 & 47
• Bone graft using INNO-OSS™ Allo • Shielding soft tissue penetration
using Wif i-Mesh
• The InnoGenic™ Wif i-Mesh, PTFE-Mesh and Ti-Mesh are non-resorbable barrier membrane to be applied over intraoral defects,
especially, tooth extraction and bone augmented sites. The InnoGenic™ Wif i-Mesh and PTFE-Mesh are made of proprietary

REID
100% PTFE, the polytetrafluoroethylene (teflon) sheet which is a biologically inactive and tissue compatible material and 3 months later
the InnoGenic™ Wif i-Mesh is reinforced with titanium frames (Titanium Gr II, ASTM F 67) embedded between two layers
of PTFE sheets.
• Removal of Wif i-Mesh • Dense periosteum layer has been
formed

InnoGenic™ Wifi-Mesh
> Packing unit : 1ea InnoGenic™ PTFE-Mesh

COWELL® IMPLANT SYSTEM


> Packing unit : 5ea

Product Code Size Thickness

BTP1424AA 14X24 0.25


BTP1424AB 14X24 0.25
BTP1525BB 15X25 0.25
BTP1725CA 17X25 0.25 Product Code Size Thickness

BTP2030AB 20X30 0.25 TS17251 17 x 25 0.1


TS24301 24 x 30 0.1

COWELL® DIGITAL PRODUCTS


BTP2530AB 25X30 0.25
BTP3040AB 30X40 0.25 TS17252 17 x 25 0.2
TS24302 24 x 30 0.2

Features
BTP1424AA BTP1424AB BTP1525BB BTP1725CA

COWELL® EXPERT INSTRUMENTS


• Non-resorbable : Made of 100% non-resorbable material for users to modulate healing period.
• Non-porous (0.0 μm) + Open Membrane Sheet Technique : Prevention of infection or other possible defects caused
from passage or integration of bacteria through porosity of plaster and it even allows to apply Open Membrane Sheet Technique.
• Prevention of Displacement : Not only being sutured along with gingival but also using BOSS® Abutment and Screw
inserted and fixed into the hole of titanium frame allows displacement of the products.
• Close to Transparency : Observation of the healing of the underlying tissue through almost transparent PTFE surface
allows more predictable result and helps determine removal time easier.
• Easy to be Customized : Easy to modify the shape according to shape and dimension of the defect.
• Easy to be Removed : Put a hook in the hole of the titanium frame of the InnoGenic™ Wif i-Mesh and in any center part of

REGENERATIVE SOLUTION
BTP2030AB BTP2530AB BTP3040AB the InnoGenic™ PTFE-Mesh and remove.

COWELL®
288 InnoGenic™ Non-resorbable Membrane InnoGenic™ Non-resorbable Membrane 289
COWELLMEDI HISTORY
Comparison to other similar products sold in market
MEMO
Classification Product A Product B InnoGenic™ Wifi-Mesh & PTFE-Mesh

SEM Photograph

REID
Ultrastructure Fiber Filter Sheet

Bacterial infection Bacterial toxin penetration Bacterial toxin penetration No Bacterial toxin penetration
at exposure between filters at 50 μm intervals between filters at 2 μm intervals thanks to non porous structure

Action on Exposure Instant Removal Removal on week 3 to 4 Safe for more than 6 weeks

Shielding Function
against Fiber Cell High High Extremely High

Shape-keeping Capability
Large Deformation Shrinkable Deformation No Deformation
against External Force

COWELL® IMPLANT SYSTEM


InnoGenic™ Ti-Mesh

• The InnoGenic™ Ti-Mesh is made of stamping titanium sheet, also Titanium Gr II, ASTMF 67, which is 100% commercially
pure titanium. The InnoGenic™ Ti-Mesh is non-resorbable surgical mesh to be applied over intraoral defects, especially, tooth
extraction and bone augmented sites.

COWELL® DIGITAL PRODUCTS


Product Code Size Thickness

TMP210 25 x 34 0.07

COWELL® EXPERT INSTRUMENTS


TMP211 25 x 34 0.1

Features
• Easy to be Customized : Easy to modify the shape according to shape and dimension of the defect.
• Prevention of Displacement : Prevents displacement of the InnoGenic™ Ti-Mesh using the BOSS® Abutment and Screw
inserted and fixed into the 1mm hole of the Ti-Mesh Frame.
• No Memory : The problem of Majority of Titanium Meshes in the market is resilience of the products after certain time.

REGENERATIVE SOLUTION
Due to this problem, patients go through serious pain. The InnoGenic™ Ti-Mesh is, however, made after many times of stamping
process, the InnoGenic™ Ti-Mesh does not come back to the original shape after shape is formed.

COWELL®
290 InnoGenic™ Non-resorbable Membrane
Ver.28
Help your daily practice superior

CWM-Ver.28

Cowellmedi Co.,Ltd Cowell R&D Institute


Floor 6, Blue Fin Tower, 42, Seochojungang-ro, Seocho-gu, Seoul, Korea 48, Hakgam-daero 221beon-gil, Sasang-gu, Busan, 46986, Korea
Tel. +82-2-3453-5085 Fax. +82-2-3453-5086 E-mail. cib@cowellmedi.com Tel. +82-51-314-2028 Fax. +82-51-314-2026

Cowellmedi USA INC


218 Trianon LN Villanova PA 19085-1442 USA
Tel. 1-623-939-1344 Fax. 1-623-939-1472

You might also like