DW-FTIR-530 FT-IR SPECTROMETER

FTIR Spectrometer DW-FTIR-530 with fully independent intellectual property rights. Adhering to consistent excellent quality and
superior performance, the new model obtains the best balance between intelligence and convenient operation , advance performance
and low operation and maintenance cost. It is a good choice for basic science research analysis, production quality control , testing
and detection in various fields.
• High sensitivity and stability

• Intelligent real - time monitoring of instrument status


Multiple communication options

• Flexible and convenient testing

• Powerful software workstation

Instrument condition
*
Laser Source Interferometer Electronic Detector

Automation Instrument

Interferometer

Temperature: 25
Innovations
Humidity: 40 % RH
Real-time diagnosis of instrument status: real-time monitoring of
instrument working status, performance and communication status.
Save OK Cancel

Optional temperature stabilized, high sensitivity DLATGS detector module,


providing stable detector response, thus ensuring high sensitivity, good reproducibility and stability of IR spectral analysis.

‘Tnternet+ detection ” instrument design with multiple communication options: Ethernet interface as standard supply for data
transfer, WIFI wireless communication as an option , adapting to ‘Tnternet+ detection ” instrument development trend, setting up
a basic platform for interconnected tests, remote operation and maintenance, and data cloud computing.

Brand-new powerful MainFTOS Suite software workstation

Modular platform design


All versions Windows OS compatible, including With data collection, processing and analysis, report print out
Windows XP, Windows 7, Windows 8, W indows 8.1 functions, and different special software functional module
and Windows 10 (32 bits and 64 bits) options

Standard data format FDA CFR 21 PART 11 Compliance


With functions as access control, authority
IEEE Floating Point Standard (* A7F).
assignment, audit trial, digital signature etc.,
IUPAC JCAMP-DX ( dx ) meet GLP/GMP and CFDA <The Computerized
Thermo Scientific OMNIC ( * .spa) JL Systems requirements

Language switch over Autmatic software updating


between Chinese and English Getting the latest software version
from the updating center

Suite

Touch control operation ' Real-time instrument status diagosis


Satisfying Windows 10' s touch control Real-time monitor of w orking status, specifications and
y
function communication status

Specialized IR libraries Secondary development library


Providing various specialized IR libraries, Providing C++ and C# development sample
code for different application development

P9
www.drawe11.com.cn
S c i e n c e

HainFTOS Suite System - [Workspace:WQF530. xml] - [Userdefault ( ADMINISTRATOR ) ] n x


MainFTOS Suite System - [Workspace: default . xml ] - [User : Default (ADMINISTRATOR) ] X
File Collect Show Convert Calculate Modify Analyse Report Set Help
File Collect Show Convert Calculate Modify Analyse Report Set Help

:
LAN
Lan
Set
s a ps
AQPARM AUTOTEST
Aqparm
Instrument set
AutoTest
AQBK
Aqbk
\& A
AQSP
Aqsp
AQSA
Aqsa
rsr mm mm ICM J W L wmr mm
AQSR

Spectrum collect
Aqsr
AQIG
Aqig
TSTB
Tstb
TSTS
Tsts
TSTA
Tsta
Spectrum test
TSTR
Tstr
TSTI
Tsti
©
STOP
Stop
Scan
aa
UserManage Register
Manage
Password
/
File
znnnmm
Collect
Signature
Change Add Save
Workstation
Send Lock
-
Record On/Off
0 Login-On/Off
Setting
I I Chinese
0 English
Language
Profile wizard 11 /Spectrum 31 /^Spectrum
s [p SEffff _
SI [ J Documents Info bar: File name : 201 5- 1 0-1 3 13-40-44 BK ASF Resolution: 4.00 Scan times : 32132 X : 24 D 2 75 Y 60 000
Profile wizard
a P a>input
IB- |=J
er
Documents Info bar: File name : 201 5-1 0 1 3 13 46 51 SP ASF
- - - Resolution:4.00 Scan times : 32f 32 X: 2402.75 Y : 60 000
12 OC 2Q c
ffl QD 12 Q D
120
110
100
90
80
70
# 60
Heme Heme
50
40
30
20
10
0

WN

El
Number Mark File name Resolution Scan times X Y A Number Mark File name Resolution Scan times X Y A

l 2015-10-13 13-40-44 BK .ASF 4.00 32/32 l 2015-10-13 13-46-51 SP . ASF 4.00 32/32 2402.751 83.945
2 2
3 3
4 4
<
Hf " FYofile .. . system i
>
.
5
oZViewfile
_ y> File preview
v <
.
> 5
If Profile ... HP system i .. |aZ View file . £> File preview |
V

Signature : Hot Signed Please wait while startting collectting ! | 2015-10-13 13: 45:22 Cable network is connectedjS ' ^' it ’ ! Not Signed Update ok w* 12015-10-13 13 : 50 : 27
1*

iature l *J
0 Use digital signature

Your are about to sign a record electronically. This is the legal


equivalent of a traditional handwritten signature.

Verify
System login

MainPTOS Suite System


a
User : Default
User : Default v
Password : ****
BRAIC ADMINISTRATOR
Signature Infomation
Password : **** WQF530 .xml
Signature : BRAIC

Time :

Reason :
2015 10
^ ^: 130
Author ship signi fi e s owner ship
v

v
Workstation: D : \ 530 \ MainFT0S SuiteVWorkStation \ WQF530 . xml v

Login Exit
Save Cancel

Features
• High sensitivity optical system : cube-corner Michelson interferometer combined with patented fixing mirror alignment
technology ( Utility model ZL 2013 2 0099730.2 : fixing mirror alignment assembly) , to ensure long term stability, without the
need of dynamic alignment which needs extra complicated electronic circuits. Reflecting mirrors are coated with gold to provide
the maximum light throughput and ensure the detection sensitivity.

• High stability modular partition design : compact structure modular design with layout on cast aluminum base and overall balance of
mechanical robustness and partition heat dissipation , offering higher ability of deformation resistance and less sensitive to
vibrations and thermal variations, greatly improves the mechanical stability and long term working stability of the instrument.

• Intelligent multi -sealed moisture-proof design : multiple sealed interferometer, large-capacity desiccant cartridge with visible
window and easy replacement structure, real -time monitoring of temperature and humidity inside the interferometer, getting rid of
influences of high temperature, high humidity and chemical corrosions to the optical system in many ways.

• Innovated integration electronic system : high sensitivity integrated DLATGS detector pre-amplifier technology, dynamic gain
amplification technology, high precision 24- bit A /D conversion technology, real-time control and data processing technology,
digital filter and network communication technology, ensuring high quality real -time data collection and high -speed transmission .
Good anti -electromagnetic interference capability: The electronic system is designed to meet CE certification and electromagnetic
compatibility requirements, minimizing electromagnetic radiation in design and technology, in line with green instrument
designing concept.

• High intensity IR source assembly: High intensity, long lifetime TR source module, with the highest energy distributed in
fingerprint region , adopts a reflex sphere design to obtain even and stable IR radiation . External isolated IR source module and
large space heat dissipation chamber design provide higher thermal stability and stable optical interference.

• The sampling compartment, reserving accessory mounting holes on the base plate, is wide enough for various accessories such
as Defused/Specular Reflection , ATR , Liquid cell , Gas cell , and IR microscope etc.

P9
www.drawe11.com.cn
Parameters

Interferometer Cube-corner Michelson interferometer


Beam splitter Multilayer Ge coated KBr
Temperature stabilized, high
Detector Room temperature DLATGS module (standard)
sensitivity DLATGS module (optional)
IR Source High intensity, long lifetime, air-cooled IR source
Wavenumber Range 7800cm ~350cm
-l - l

Resolution 0.85 cm - 1

Better than 20,000:1 (RMS value,


Signal to noise ratio at 2100cm - l ~ 2000cm - l or 2100cm - l ~ 2200cm - l ,
-l
resolution: 4cm , detector: DLATGS,
1 minute data collection)
Wavenumber Accuracy ±0.01 cm - 1

Scanning Speed Microprocessor control, different


scanning speed selectable.

MainFTOS Suite software workstation, Various specialized functional


Software
compatible to all version Windows OS software modules (optional)
Communication Ethernet interface (standard) WIFI wireless communication (optional)
Data Output Standard data format, report generation and output

Power on self check, real-time temperature and


Status Diagnosis
humidity monitoring and reminders
Certification IQ/OQ/PQ ( Optional )
Environment Conditions Temperature: 10℃^30℃ , humidity: less than 70%
Power Supply AC220V±22V , 50Hz± lHz AC110V (optional )
Dimensions & Weight 520 x 435 x 255mm, 24kg
Optional accessories such as gas cell,
Accessories Transmission sample holder (Standard) liquid cell, Defused/Specular Reflection,
single/multi reflection ATR, etc.

P15
www.drawe11.com.cn