Technicool Systems TCS-P-A-V01GS-GP-120HOO0D-ROS2-FHGA 10 Ton Roof-Mount HVAC Manual of Operation Standard Limited Warranty FULL ONE-YEAR WARRANTY — During the first year after purchase, TECHNICOOL SYSTEMS wil, free of charge to the user or subsequent users, repair or replace any parts which are defective in material or workmanship. The replacement part can be a new or remanufactured part as provided at TECHNICOOL SYSTEMS'S sole option, LIMITATION OF WARRANTIES — ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH EACH LIMITED. WARRANTY IS GIVEN AND APPLIES. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. ALL WORK UNDER THE TERMS OF THIS WARRANTY ‘SHALL BE PERFORMED DURING NORMAL WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY. TECHNICOOL SYSTEMS WILL NOT BE RESPONSIBLE FOR: 1. CLEANING REQUIRED PRIOR TO WARRANTY REPAIR. 2. Standard maintenance, cleaning or damage resulting from failure to perform normal maintenance as outlined in the owner's manual. 3. Instruction on methods of control and use of air conditioning unit after initial installation. 4, Damage or repairs needed as a consequence of faulty installation or application. This is the responsibility of the installer. 5. Failure to start due to voltage conditions, blown fuses, open circuit breakers or any other damages due to the inadequacy or interruption of electrical services. 6. Damage or repairs needed as a consequence of any misapplication, abuse, unauthorized alteration, improper servicing or operation. 7. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environment, or other conditions beyond the control of TECHNICOOL SYSTEMS. EXCEPTION TO CORROSIVE ENVIRONMENT IN ABOVE PARAGRAPH — Units built with corrosion protection are exempt from the exclusion — “Corrosive Environment”, 8. Reimbursement for replacement parts or repair services which are not supplied or designated by TECHNICOOL SYSTEMS and which are specifically covered under this warranty. 9. TECHNICOOL SYSTEMS products installed outside the continental U.S.A, Alaska, Hawaii and Canada 10. Shipping damage or damage as a result of transporting the unit. 11. ANY SPECIAL, INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion or limitation of incidental or consequential damages, s0 the above limitation or exclusion may not apply to you 12. Warranty coverage of accessory items (wall thermostats, wall sleeves, etc.). NOTE: Service and Maintenance items excluded in this warranty may be covered by a separate service agreement through the seller at time of purchase Technicool Systems Manual of Operation TCS-P-A-V01GS-GP-120N000C-R0S2-FHGA Revision 1.1 Page 2 WARNING ELECTRICAL SHOCK HAZARD Failure to follow safety warnings exactly could result in serious injury, death, and/ or property damage. Turn off electrical power at fuse box or service panel BEFORE making any electrical connections and ensure a proper ground connection is made before connecting line voltage. Disconnect electrical power at the fuse box or disconnect before attempting any maintenance on the unit. BEFORE using a water hose or pressurized air to clean outdoor coil, DO NOT forget to turn off electrical power. IMPORTANT All electrical work must meet the requirements of local codes and ordinances. Work should be done ONLY by qualified persons. Keeping the air filters clean and recognizing the importance of clean outdoor coils are key elements, The air filters should be inspected at least monthly. The air conditioner should have periodic inspections made by a trained professional, who has the experience, knowledge, training, licensing, certifications, and the necessary tools and equipment required to do these tasks properly and in accordance with approved or mandated procedures. The inspection could be made annually. Technicool Systems Manual of Operation TCS-P-A-V01GS-GP-120N000C-R0S2-FHGA Revision 1.1 Page 3 Unit Selector Guide Tes - wW- APF - VOIGS - GP - 144NO09C - ROS1 ~ FHGA - DK ®O660 06 6 A: OEM TCS: Technicool BRD: Bard RUD: Ruud TRN: Trane YRK: York, B: Mounting P: Packaged SC: Split Condenser SA: Split Air Handler W: Wall C: Unit Type A: HVAC F: Chemical Filtration P: Pressurization D: Revision VXX: Revision Digits 3-4: Material Materials AL: Aluminum GS: Galvanized Steel SS: Stainless Stee! E: Classification CIDE: Class |, Div! CIDII: Class |, Div I GP: General Purpose F: HVAC Specifications Digits 0-2: Cooling Capacity in KBTU/H Digit 3: Ambient Temperature Digits 4-6: Heating Capacity in KW Digit 7: Electrical Specification Ambient Temperatures H: 56°C L:-40°C N:40 °C Electrical Specifications A: 208-230V/1P / 60 Hz B: 208-230V / 3P /60 Hz C:460V /3P /60 Hz D:575V/3P /60 Hz E:220V/ 1P/50 Hz F:380V/3P /50 Hz G: Redundancy / Staging RX: Redundancy Level in 100% SX: Number of Cooling Stages © © 0 H: Physical Options Digit 0: Cooling Flow Digit 1: Condenser Discharge Digit 2: Paint Digit 3: Internal Use Only Cooling Flow Options F: Forward (Up) Flow R: Reverse (Down) Flow Condenser Discharge Options H: Horizontal Back S: Horizontal Side V: Vertical Paint Options B:Blue C:Custom G:Gray U: Unpainted W:White Misc. Options D: Fresh Air Damper H: Hail Guard L:Lead Lag K: Coil Coating X: Enhanced Controls Notes: Some options are dependant upon mounting or unit types. Additional options are available upon request. This selector guide is subject to change. Technicool Systems TCS-P-A-VO01GS-GP-120NO000C-ROS2-FHGA Manual of Operation Revision 1.1 Page 4 General Unit Information ‘SEQUENCE OF OPERATION AIR CONDITIONING During normal operation, the thermostat reads the room temperature. In cooling mode, once the room temperature reaches the temperature set-point plus two degrees, the thermostat outputs to the blower motor, outdoor fan motor, and the compressors. These remain activated until the room temperature reaches the temperature set-point minus two degrees. COMPRESSOR CONTROL The compressor is protected from short cycle by an, on-delay timer. If control power breaks, the on-delay timer will prevent the compressors from turning on for a period of three to five minutes. Technicool Systems TCS-P-A-V01GS-GP-120N000C-R0S2-FHGA HIGH PRESSURE AND LOW PRESSURE SWITCHES The unit is protected by refrigerant high pressure and low pressure switches. If the refrigeration lines have a pressure higher or lower than the threshold, the compressors will be disabled to protect the unit. PRESSURE SERVICE PORTS High and low pressure service ports are installed on all units so that the system operating pressures can be checked. PHASE MONITOR This unit contains a phase monitor for phase reversal, phase loss, and unbalanced phase. If the incoming phase is incorrect, the unit will not function Manual of Operation Revision 1.1 Page 5 General Unit Information PERIODIC MAINTENANCE Periodic maintenance must be conducted on your system to insure maximum and proper performance, especially during peak operating periods and conditions. Keep the air filters clean and recognizing the If the unit is equipped with the enhanced control option, the unit has a Siemens PLC and touch screen installed, TOUCH SCREEN INTERFACE CONTROL The control section of the touch screen contains the ability to change the temperature set-point, as well as importance of clean outdoor coils are key elements to the air conditioning and pressurization fan operating maintaining proper performance. Be sure to change air filters at least monthly. The condensate drain system must be kept open and free to convey the condensate generated by the operation of the unit. Make sure that the outdoor coils are clean and are not blocked with any foreign matter or otherwise restricted with any growth or other items. Frequent, cleaning of the outdoor coils using a water hose or pressured air will help maintain the integrity of the unit, DO NOT FORGET TO REMOVE POWER FROM. THE UNIT BEFORE ATTEMPTING TO CLEAN THE COILS WITH WATER. The unit should have periodic inspections made by a trained professional, who has the experience, knowledge, training, licensing, certifications, and the necessary tool and equipment required to do these tasks properly and in accordance with approved or modes. Also contained on this page are the current room temperature and the pressure differential out- puts DIAGNOSTICS On the diagnostics screen, useful information for diagnosing air conditioning problems can be found. Included are the room, supply, and return tempera- tures, along with the blower and condenser fan motor currents, STATUS The status screen shows the current output status of the various parts of the unit. This can be useful for identifying problems with your unit if the output sta- tus does not match the actual status of the unit. ALARMS mandated procedures. The inspection should be doneThe alarms page shows the internal troubleshooting annually at minimum. Proper and routine maintenance and service will protect the unit and avoid disruption in building operation, Technicool Systems TCS-P-A-V01GS-GP-120N000C-R0S2-FHGA alarms of the unit. These alarms are written in human- readable language that can be very helpful in deter- mining any problems the unit may have. INFO This screen contains our contact information. In the event of unit troubles, please feel free to give us a call Manual of Operation Revision 1.1 Page 6 Unit Dimensions and General Layout 4'-5 13/16" 1-10 7/16"=1'-5 3/4" 1 she 0 2-13/4"— / 23" 13.14" 0 2-13/4"— { L 213/16" —2-21/4" 2-21/2" 1-8 5/8" 1-8 5/8" 2-6 11/16" | 8 u a( te) 35 Zl = 4 L_.. -2"—+| 91/24 91/2" Technicool Systems TCS-P-A-V01GS-GP-120N000C-R0S2-FHGA Manual of Operation Revision 1.1 Page 7 Unit Dimensions and General Layout \ \ 1423/8" ||, 1/2" / DETAILA Re 1-23/8" | 23/16" 0 11/2" o1 Ta 0 15/8" DETAILB Technicool Systems Manual of Operation TCS-P-A-V01GS-GP-120N000C-R0S2-FHGA Revision 1.1 Page 8 Unit Dimensions and General Layout [slower ITEM NUM PART NAME aw, 1_[ FRT30v 106A FORMED CHANNEL 2 [EXTEROREVAPORATOR CORNER ARACKET [2 3___ | FRTINTERIOR EVAPORATOR CORNER BRACKET 4 INTEROR CORNER PANEL 5 EXTERIOR CORNER BRACKET 6 __ [srw noRzoviat evaroraToRsraceer | 2 7__| BTW CONDENSER HORZONTAL BRACKET & | ToPHoRZonTALevaPoRAToRGRAcKET | 2 2 | CONDENSER HORIZONTAL BRACKET 0 [EvapoRaToR cou 2 [atower sox 2 | cowpaesson 14 _ | CONDENSERTOP Paw s_[ evaronaTORTOP 6 _ | CONDENSER FAN a7_[ventuw 8 _| CONDENSER CON 79__| cONDENSERFLOOR 20__ | PARTITION PANEL PORATOR FLOOR a _[aGanae [~e |_ © _8 Le L@ Technicool Systems TCS-P-A-VO01GS-GP-120NO000C-ROS2-FHGA = & Manual of Operation Revision 1.1 Page 9 Electrical Data and Design Specifications Electrical Rating: 460V / 3P / 60 Hz Minimum Circuit Ampacity: 40A Maximum Overcurrent Protection: 45A Motor ary| v Pp HP RPM FLA RLA LRA Compressor 2 460 3 3500 1.5 78 Evaporator 1 460 3 5 1750 6.6 Condenser 2 460 1 75. 1075 2.2 Design Ambient Working Temperature: 0 °F - 104 °F (-18 °C - 40 °C) Unit Weight: 1300 Ibs. Refrigerant: R410A Refrigerant Charge: Circuit 1: 108 oz Circuit 2: 108 oz Technicool Systems TCS-P-A-VO01GS-GP-120NO000C-ROS2-FHGA Manual of Operation Revision 1.1 Page 10 Electrical Data and Design Specifications Technicool Systems Manual of Operation TCS-P-A-VO01GS-GP-120NO00C-ROS2-FHGA Revision 1.1 Page 11 Electrical Data and Design Specifications a uo B Q) [2) 46ovac-sonz-2P ps eM » 6) @& 4 > @| @ 5 iFM ni ‘ 2) & 7 \ i" a) @ ' i) a ° OFC > us 13) 3 L \ ‘ a. “ compa a Gi 5 cc2 » a 13) 19 \ a. 1 {comer a fa ca Technicool Systems Manual of Operation TCS-P-A-V01GS-GP-120N000C-R0S2-FHGA Revision 1.1 Page 12 Electrical Data and Design Specifications sT2 Lpc2 HPC2 FPS2 35 20) 21 24 26 31) 27 28: 29 32 33 34 sti LPC1 HPC1 FPS1 30 LOW VOLTAGE TERMINAL BLOCK WIRING Technicool Systems TCS-P-A-VO01GS-GP-120NO000C-ROS2-FHGA Manual of Operation Revision 1.1 Page 13 Electrical Data and Design Specifications ea = eI = 2g 75 @ @ F Las cae ue Te a F _ @ a joy | l Js) B= o® elele é | 2 lat & sca Ex) B| oc a) peo os = pee : 4 E Technicool Systems Manual of Operation TCS-P-A-V01GS-GP-120NO00C-ROS2-FHGA Revision 1.1 Page 14 Refrigerant Flow Diagram Technicool Systems Manual of Operation TCS-P-A-V01GS-GP-120N000C-R0S2-FHGA Revision 1.1 Page 15

You might also like