Enables open and secure 3rd party OPC access to PREPARE FOR THE FUTURE WITH OPC CLASSIC-OPC
your Allen Bradley PLCs! UA INTEGRATION
Figure 1 Matrikon OPC Server for Allen Bradley connect to any Allen
Bradley PLCs using either method with the addition of the Matrikon OPC
UA TunnellerTM.
FEATURES & BENEFITS
KEY FEATURES:
Supports connectivity to ControlLogix, CompactLogix, PLC5, SLC500, and Micrologix
Automatic detection of PLC configuration changes (when Program->Run mode invoked)
Optimized performance and memory utilization
Loading of device configuration files .l5k, .pc5, and .slc
Bit writes through OPC tags
Automatic discovery of devices
Supports custom, user-defined structures in ControlLogix PLC’s
Superior graphic user interface to enhance usability
Enhanced health monitoring
Support for Rockwell EN2T communication card
Supports DF1 Serial, ThernetIP (CIP), DH+/DH485, Ethernet to 1761 to Serial
Modular, high-performance control platform suited for sequential, process, drive, and motion control
Wide range of analog, digital and specialty I/O modules
Serial port settings are automatically configured
Tags are automatically generated for each device
Supports device-level redundancy through fail-over channels
CUSTOMER BENEFITS:
Matrikon OPC Server for Allen Bradley - Datasheet ©Matrikon Inc. 2022
ALLEN BRADLEY PORTS AND PROTOCOLS
The table below shows what protocols and ports are used and supported by the Matrikon® Server for Allen
Bradley PLCs:
ControlLogix NO NO YES NO
Powerflex NO NO YES NO
YES - Supported and has been tested in the Matrikon lab • NO - Not supported.
Notes:
1. Matrikon OPC Server for Allen Bradley PLCs supports DH+/DH485 connections using one of these
methods:
- KF2/KF3 RS-232 adaptor
- ControlLogix DHRIO module
The items marked YES for DH+/DH485 can use any of these methods.
2. PKTX card no longer supported
3. The Matrikon OPC Server for Allen Bradley PLCs does not support ControlNet nor DeviceNet.
4. Program tags not supported. Should a Program Tag be required via the OPC Server, it is recommended
the PLC be programmed to map the required Program Tag(s) to accessible Controller Tag(s)
Matrikon OPC Server for Allen Bradley - Datasheet ©Matrikon Inc. 2022
SUPPORTED OPC SPECIFICATIONS
SYSTEM REQUIREMENTS:
Software Requirements:
• Windows 7, 10 and 11
• Windows Server 2008, 2012, 2016, 2019 and 2022
• Microsoft .Net 3.5 Framework
Hardware Requirements:
• Intel® CORE I5
• 2 GB RAM
• 80 GB 7200 RPM Hard Drive
Cables:
• Serial (RS232)
• Serial (RS485)
• Ethernet
• "Blue Hose"
More Information
To learn more about Matrikon, visit
www.MatrikonOPC.com or contact
your Matrikon account manager.
Matrikon
Americas:
Phone: 1-780-448-1010
Fax: 1-780-448-9191
houston@MatrikonOPC.com
EMEA:
Phone: +49 221-96977-0
europe@MatrikonOPC.com
Asia-Pacific:
Phone: +61 (2) 4960-1000
Fax: +61 (2) 4960-1212
asiapacific@MatrikonOPC.com
Matrikon OPC Server for Allen Bradley - Datasheet ©Matrikon Inc. 2022