You are on page 1of 12

Installation: Transformer

Standard (Indoor/ Frequency Rated Power


Item Transformer Type IEC/IEEE/ANSI Outdoor) Phase (Hz) (KVA)
Cast Coil Dry Type
1 Transformer IEC 60076-11:2018 Indoor 3 60Hz 300KVA
Cast Coil Dry Type
2 Transformer IEC 60076-11:2018 Indoor 3 60Hz 500KVA
Cast Coil Dry Type
3 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1000KVA
Cast Coil Dry Type
4 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1500KVA
Cast Coil Dry Type
5 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1600KVA
Cast Coil Dry Type
6 Transformer IEC 60076-11:2018 Indoor 3 60Hz 2000KVA
Cast Coil Dry Type
7 Transformer IEC 60076-11:2018 Indoor 3 60Hz 2500KVA
Cast Coil Dry Type
8 Transformer IEC 60076-11:2018 Indoor 3 60Hz 3000KVA
Cast Coil Dry Type
9 Transformer IEC 60076-11:2018 Indoor 3 60Hz 3500KVA

Cast Coil Dry Type


9 Transformer IEC 60076-11:2018 Indoor 3 60Hz 300KVA
Cast Coil Dry Type
10 Transformer IEC 60076-11:2018 Indoor 3 60Hz 500KVA
Cast Coil Dry Type
11 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1000KVA
Cast Coil Dry Type
12 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1500KVA
Cast Coil Dry Type
13 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1600KVA
Cast Coil Dry Type
14 Transformer IEC 60076-11:2018 Indoor 3 60Hz 2000KVA
Cast Coil Dry Type
15 Transformer IEC 60076-11:2018 Indoor 3 60Hz 2500KVA
Cast Coil Dry Type
16 Transformer IEC 60076-11:2018 Indoor 3 60Hz 3000KVA
Cast Coil Dry Type
17 Transformer IEC 60076-11:2018 Indoor 3 60Hz 3500KVA

Cast Coil Dry Type


18 Transformer IEC 60076-11:2018 Indoor 3 60Hz 300KVA
Cast Coil Dry Type
19 Transformer IEC 60076-11:2018 Indoor 3 60Hz 500KVA
Cast Coil Dry Type
20 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1000KVA
Cast Coil Dry Type
21 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1500KVA
Cast Coil Dry Type
22 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1600KVA
Cast Coil Dry Type
23 Transformer IEC 60076-11:2018 Indoor 3 60Hz 2000KVA
Cast Coil Dry Type
24 Transformer IEC 60076-11:2018 Indoor 3 60Hz 2500KVA
Cast Coil Dry Type
25 Transformer IEC 60076-11:2018 Indoor 3 60Hz 3000KVA
Cast Coil Dry Type
26 Transformer IEC 60076-11:2018 Indoor 3 60Hz 3500KVA

Cast Coil Dry Type


27 Transformer IEC 60076-11:2018 Indoor 3 60Hz 300KVA
Cast Coil Dry Type
28 Transformer IEC 60076-11:2018 Indoor 3 60Hz 500KVA
Cast Coil Dry Type
29 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1000KVA
Cast Coil Dry Type
30 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1500KVA
Cast Coil Dry Type
31 Transformer IEC 60076-11:2018 Indoor 3 60Hz 1600KVA
Cast Coil Dry Type
32 Transformer IEC 60076-11:2018 Indoor 3 60Hz 2000KVA
Cast Coil Dry Type
33 Transformer IEC 60076-11:2018 Indoor 3 60Hz 2500KVA
Cast Coil Dry Type
34 Transformer IEC 60076-11:2018 Indoor 3 60Hz 3000KVA
Cast Coil Dry Type
35 Transformer IEC 60076-11:2018 Indoor 3 60Hz 3500KVA
Temperature
rise at
Rated Rated Insulation principal
High Low Tapping on HV Type of system tapping Winding
Voltage Voltage (De-energized Vector Step Down/ cooling thermal class (HV/LV) Conductor
(KV) (V) tap changer) Group Step up (AN or AF) (HV/LV) [°C] [K] (HV/LV)

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

13.8KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu
33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AN H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu

33KV 400 ± 2 steps X 2.5 % Dyn11 Step Down AF+40% H/H (180/180) 115/115 Cu/Cu
Ambient
temperature Dimension
BIL (LV BIL (MV (Max./ Altitude Enclosure (Transformer /
Secondary) Primary) Monthly / (below -) Impedance Degrees of Enclosure)
(KV) (KV) Yearly) [°C] [m] C/E/F class [%] Protection Width (mm)

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31 1400

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31 1600

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31 1600

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31 1600

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31 1800

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31 1800

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31 1800

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31 1800

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 7% IP31 1800

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31 1400

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31 1600

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31 1600

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31 1600

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31 1600

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31 1800

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31 1800

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31 1800

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 7% IP31 1800

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31


1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31 1600

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31 1600

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 7% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 5% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 6% IP31

1KV 95KV 50/40/30 °C 1000m C2/E2/F1 7% IP31


Dimension
Dimension (Transformer /
(Transformer / Enclosure)
Enclosure) Height (with Unit Budget
Length (mm) Rollers) (mm) Weight (Kg) Price in (KSAR)

1800 1700 1850

1900 1900 2250

1900 2200 3100

2100 2300 3950

2200 2400 4700

2300 2400 5500

2400 2500 6300

2600 2800 8000

2700 2900 9300

1800 1750 1950

1900 1950 2350

1900 2250 3200

2100 2300 4300

2200 2400 4650

2300 2400 5400

2500 2500 6700

2650 2850 8350

27550 3000 9500


2200 2400 3600

2400 2500 4700


Rated Rated
Transformer High Low Tapping on HV
Frequency Rated Power Voltage Voltage (De-energized
Item Transformer Type Phase (Hz) (KVA) (KV) (V) tap changer)
Mineral Oil Type
1 Transformer 3 60Hz 300KVA 13.8KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
1 Transformer 3 60Hz 500KVA 13.8KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
2 Transformer 3 60Hz 1000KVA 13.8KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
3 Transformer 3 60Hz 1500KVA 13.8KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
4 Transformer 3 60Hz 1600KVA 13.8KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
5 Transformer 3 60Hz 2000KVA 13.8KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
6 Transformer 3 60Hz 2500KVA 13.8KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
7 Transformer 3 60Hz 3000KVA 13.8KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
8 Transformer 3 60Hz 3500KVA 13.8KV 400 ± 2 steps X 2.5 %

Mineral Oil Type


9 Transformer 3 60Hz 300KVA 33KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
10 Transformer 3 60Hz 500KVA 33KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
11 Transformer 3 60Hz 1000KVA 33KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
12 Transformer 3 60Hz 1500KVA 33KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
13 Transformer 3 60Hz 1600KVA 33KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
14 Transformer 3 60Hz 2000KVA 33KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
15 Transformer 3 60Hz 2500KVA 33KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
16 Transformer 3 60Hz 3000KVA 33KV 400 ± 2 steps X 2.5 %
Mineral Oil Type
17 Transformer 3 60Hz 3500KVA 33KV 400 ± 2 steps X 2.5 %
Temperature
rise at
Insulation principal
Type of system tapping Winding BIL (LV BIL (MV
Vector Step Down/ cooling thermal class (HV/LV) Conductor Secondary) Primary)
Group Step up (HV/LV) [°C] [K] (HV/LV) (KV) (KV)

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV

Dyn11 Step Down ONAN Class A (105°C) 55 °C Cu/Cu 1KV 95KV


Ambient Altitude
temperature (below -) Impedance Dimension Dimension Dimension
[°C] [m] [%] Width (mm) Length (mm) Height (mm) Weight (Kg)

50 °C 1000m 5%

50 °C 1000m 5%

50 °C 1000m 5% 1650 1680 1870 2600

50 °C 1000m 5% 1770 1910 1950 3500

50 °C 1000m 6% 1770 1910 1960 3500

50 °C 1000m 6% 1910 2100 2060 4600

50 °C 1000m 6% 1950 2150 2230 5300

50 °C 1000m 6% 1990 2200 2290 6750

50 °C 1000m 7% 2030 2250 2400 8000

50 °C 1000m 5%

50 °C 1000m 5%

50 °C 1000m 5% 1850 1900 2000 3150

50 °C 1000m 5%

50 °C 1000m 6%

50 °C 1000m 6% 2100 2250 2200 4950

50 °C 1000m 6%

50 °C 1000m 6%

50 °C 1000m 7%
Unit Budget