Customer :

Contact :
Project : Phone : Fax :
Quote No. : US-1817-88 Page No : 1 Date : Monday, 23 de April de 2018

Type: AE Horiz Mtg - Horizontal Split Case Single Stage Item : 1


Pump Model: Peerless - 10AE20 Impeller No.: 2693541
Nom. Speed: 1775 RPM, 60 Hz Electric Fluid: Water
Impeller Dia.: 19,99 inch Temperature: 68 °F
Curve No.: 3132078 Viscosity: 1,007 cSt
Market : Water Sp. Gravity: 1,000
Your Ref. :

D1-20,00 inch, D2-19,00 inch, D3-18,00 inch, D4-17,00 inch, Duty Flow 5000 US gpm
D5-15,50 inch, D6-14,50 inch 90
Duty Head 145 psi
200 80
Imp. Dia. 19,99 inch

Efficiency - %
70
Head - psi

150 60 Power Required 520,4 hp


D1 50 NPSH Required 16,2 ft
100 40 Efficiency 83,8 %
30 Peak Power 549,1 hp
D6
50 20
Closed Valve Head 195,6 psi
10
Tolerance Hyd Ins 14.6
Unilateral
NPSH - ft

30
20
10
Power - hp

500
400 Comments
300
200 Performance curve represents
100 typical performance. See Hydraulic
Performance document in RAPID
for perfomance test acceptance
2.000 4.000 6.000 8.000 grades/tolerances & contractual
Flow - US gpm
Flow Head Efficiency Power Required NPSH Required
(US gpm) (psi) (%) (hp) (ft)
2069,5 189,1 68,2 334,8 7,0
2553,3 186,1 74,6 371,6 7,9
3037,0 181,9 78,9 408,5 8,6
3520,8 176,3 81,7 443,4 9,7
4004,5 169,1 83,3 474,2 11,2
4488,3 160,3 84,1 499,7 13,1
4972,0 150,0 83,8 519,5 16,0
5455,8 138,2 82,3 534,9 22,4
5939,5 125,0 78,9 549,1 37,0

Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.


Pump Model: Peerless - 10A E20 Nom. Speed: 1775 RPM, 60 Hz Electric Temperature: 68 °F
Curve No.: 3132078 Impeller Dia.: 19,99 inch Viscosity: 1,007 cSt
Impeller No. 2693541 Fluid: Water Sp. Gravity: 1,000
Tolerance : Hyd Ins 14.6 Unilateral

D1-20,00 inch, D2-19,00 inch, D3-18,00 inch, D4-17,00 inch, D5-15,50 inch, D6-14,50 inch

90

200 80

70

150 60

Efficiency - %
Head - psi

D1 50

100 40

30
D6
50 20

10

30
NPSH - ft

20

10

500

400
Power - hp

300

200

100

2.000 4.000 6.000 8.000


Flow - US gpm
Comments:
Performance curve represents typical performance. See Hydraulic Performance document in RAPID for perfomance test acceptance
grades/tolerances & contractual guarantees..

Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.


Customer :

Contact :
Project : Phone : Fax :
Quote No. : US-1817-88 Page No : 3 Date : Monday, 23 de April de 2018

Item: 1 Flow (US gpm) Head (psi) Eff. (%) Power (hp) Speed (RPM)
Model : Peerless - 10AE20
5000 145 83,8 520,45 1775

Liquid Temp. (°F) Sp. Gravity Visc. (cSt) Dia. (inch)

Water 68 1,000 1,007 19,99

Technical Information:

Technical Information: 10AE20

Casing Suction Design Double


Casing Volute Design Double
Nominal Casing Thickness Inches 0,75
Corrosion Allow Inches 0,12
Max Suct Press PSI MechSeal 125# Suct less than or = to 150°F CI 90 (T 21 Seal) 150 (T 1 Seal)
Max Suct Press PSI MechSeal 250# Suct less than or = to 150°F CI Refer to factory
Max Suct Press PSI MechSeal 250# Suct less than or = to 150°F DI Not Available
Max Suct Press PSI Packed 125# Suct CI Csg 175
Max Suct Press PSI Packed 250# Suct CI Csg Refer to factory
Max Suct Press PSI Packed 250# Suct DI Csg Not Available
Max Work Press PSI MechSeal 125# Dischg less than or = to 150°F CI 175
Max Work Press PSI MechSeal 250# Dischg less than or = to 150°F CI 250
Max Work Press PSI MechSeal 250# Dischg less than or = to 150°F DI Refer to factory
Max Work Press PSI Packed 125# Disch CI Csg 175
Max Work Press PSI Packed 250# Disch CI Csg 250
Max Work Press PSI Packed 250# Disch DI Csg Not Available
Max Suct Press PSI Mech Seal 125# Suct 200°F CI (NA-T 21 Seal) 150 (T 1 Seal)
Max Suct Press PSI Mech Seal 250# Suct 200°F CI Refer to the Factory
Max Suct Press PSI Mech Seal 250# Suct 200°F DI Not Available
Max Suct Press PSI Packed 125# Suct 200°F CI 162
Max Suct Press PSI Packed 250# Suct 200°F CI Refer to the Factory
Max Suct Press PSI Packed 250# Suct 200°F DI Not Available
Max Work Press PSI Mech Seal 125# Disc 200°F CI 162

Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.


Customer :

Contact :
Project : Phone : Fax :
Quote No. : US-1817-88 Page No : 4 Date : Monday, 23 de April de 2018

Max Work Press PSI Mech Seal 250# Disc 200°F CI 232
Max Work Press PSI Mech Seal 250# Disc 200°F DI Not Available
Max Work Press PSI Packed 125# Disch 200°F CI 162
Max Work Press PSI Packed 250# Disch 200°F CI 232
Max Work Press PSI Packed 250# Disch less than or = to 200°F DI Not Available
Max Suct Press PSI Mech Seal 125# Suct less than or = to 225°F CI (NA-T 21 Seal) 150 (T 1 Seal)
Max Suct Press PSI Mech Seal 250# Suct less than or = to 225°F CI (NA-T 21 Seal) 150 (T 1 Seal)
Max Suct Press PSI Mech Seal 250# Suct less than or = to 225°F DI Not Available
Max Suct Press PSI Packed 125# Suct less than or = to 250°F CI 150
Max Suct Press PSI Packed 250# Suct less than or = to 250°F CI Refer to the Factory
Max Suct Press PSI Pack 250# Suct 250° F DI Not Available
Max Work Press PSI Mech Seal 125# Dischg less than or = to 225°F CI 160
Max Work Press PSI Mech Seal 250# Dischg less than or = to 225°F CI 225
Max Work Press PSI Mech Seal 250# Dischg less than or = to 225°F DI Not Available
Max Work Press PSI Pack 125# Dischg less than or equalto 250°F CI 150
Max Work Press PSI Packed 250# Dischg less than or = to 250°F CI 215
Max Work Press PSI Packed 250# Dischg less than or = to 250°F DI Not Available
Shaft Diameter Through mpeller
I Inches 2,75
Shaft Dia Through Coupl
ing Inches 2,5
Cutwater Diameter Inches 21,25
Impeller Diameter at 90% of Cutwater Diameter 19,13
Impeller Diameter at 85% of Cutwater Diameter 18,06
Minimum Impeller Diameter Inches 15
Minimum Impeller Average Diameter Inches Not Applicable
WR2 Lb-Ft2 Wet Bronze Impeller 37,4
Number ofImpeller Vanes 7
Stuffing Box Shaft Sleeve Diameter Inches 3,125
Stuffing Box Bore Inches 4,375
Stuffing Box Depth Inches 4,62
Stuffing Box Face Nearest Obstruction Along Shaft In 3,06
Stuffing Box Square Packing Inches 0,625
Stuffing Box Packing Rowswithout Lantern Ring 6

Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.


Customer :

Contact :
Project : Phone : Fax :
Quote No. : US-1817-88 Page No : 5 Date : Monday, 23 de April de 2018

Stuffing Box Packing Rowswith Lantern Ring 5


Stuffing Box Gland Bolt Circle 7,5
Stuffing Box Gland Bolt Dia Inches 0,625
Radial Single Row Bearing Size 213
Thrust Single Row Bearing Size 311
Thrust Double Row Bearing Size Optional 5311
Priming Connection NPT 1
Discharge Drain NPT 1
Suction Drain NPT 1
First Critical Speed RPM 3251
Max Pump RPM Standard Construction 1800
Max Pump RPM 1900
Rotor Series 6
Specific Speed 8 Pole 60Hz Motor 0
Specific Suction Speed 8 Pole 60Hz Motor 0
Specific Speed 6 Pole 60Hz Motor 1015
Specific Suction Speed 6 Pole 60Hz Motor 9150
Specific Speed 4 Pole 60Hz Motor 1015
Specific Suction Speed 4 Pole 60Hz Motor 11680
Specific Speed 2 Pole 60Hz Motor 0
Specific Suction Speed 2 Pole 60Hz Motor 0

Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.


Customer :

Contact :
Project : Phone : Fax :
Quote No. : US-1817-88 Page No : 6 Date : Monday, 23 de April de 2018

Item: 1 Flow (US gpm) Head (psi) Eff. (%) Power (hp) Speed (RPM)
Model : Peerless - 10AE20
5000 145 83,8 520,4 1775

Liquid Temp. (°F) Sp. Gravity Visc. (cSt) Dia. (inch)

Water 68 1,000 1,007 19,99

Typical Specification:

Type AE Horizontal Split Case Single Stage Pump Typical Specifications

General: The pump(s) shall be ofthe single stage, double suction (except 2AE11 which is single suction),
horizontal split case design; split on the horiz ontal axis and shall be bronze fitted construction. Suction and
discharge connections shall be located on opposite sides of the lower casing, allowing remov al of the rotating
element without disturbing the system piping connections.

The pump(s) are to be designed for a capacity of 5000 US gpm at a total head of 145 psi, at an efficiency of 83,8%
of design condit ion.

The pump(s) shall be a Peerless Pump Company model 10AE20 and shall be of the axial split case type.

Casing: The pump casing material shall be a minimum of class 35 cast iron. Water passageways shall be smooth
to permit maximum efficiency. Casing shall be hydrostatically tested at 150% of the maximum working pressure
under which the pump could ope rate at design speed. The suction flange shall be drilled (125 lb.)(250 lb.) ANSI.
The discharge flange shall be drilled (125 lb.
) (250 lb.) ANSI.

The bearing brackets shall be cast as an integral part of the lower casing and have removable bracket caps. The
bearing housing shall be doweled for location and anti-rotation. The pump feet shall also be cast as an Integral part
of the lower casing.

Bronze renewable casing rings shall be furnished, doweled and shouldered In the casing. Ring dowels shall be
located In slots on the split surface of the lower casing.

Impeller: The impeller shall be ofone piece cast bronze, double suction type (except 2AE11 which is single
suction). The impeller shall be balanced, keyed to the shaft and fixed in an axial position by threaded shaft sleeves.
The Impeller skirt sh all be groov
ed and fit with close tolerances to the casing ring to permit a minimum of
recirculation between the impeller and he
t casing ring for maximum efficiency.

(Optional: Renewable bronze impeller ringsshall be shrunkon the impeller and lock ed in place with stainless steel
set screws. The impeller ringsshall be grooved and fit with close tolerances to the casing ring for maximum
efficiency.)

Stuffing Boxes:

Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.


Customer :

Contact :
Project : Phone : Fax :
Quote No. : US-1817-88 Page No : 7 Date : Monday, 23 de April de 2018

Pack ing - The stuffing boxes shall hold a minimum offive rings of TFE packing. The bronze gland shall be split in
two halves, to facilitate removal for repacking. Gland bolts shall be ofthe swing ty pe made ofsteel with 18-8
stainless steel nuts.

Mechanical Seal - Sealing of the pump liquid cavity shall be with a face type mechanical seal with ceramic
stationary seat, carbon sealing washer, Buna rubber lexible
f members, stainless steel metal parts and spring. Seal
to be rated for 225°F(107 °C) @ 150 psig (10-34 bar) maximum. Mechanical seals shall be mounted over bronze
shaft sleeves.

Shaft and Shaft Sleeves: The shaft shall be carbon steel, adequately sized for the loads transmitted. Shaft
deflection shall not exceed .002 Inches at the face of the stuffing boxwhen operating between 95% and 105% of
capacity at best efficiency a t the pump's maximum 60 Hz. speed and wit h full diameter Impeller.The shaft shall be
protected through h t e stuffing boxby means of bronze shaft sleeves and they shall be threaded against shaft
rotationand ol cked in place with set screws. The sleeves sha ll be sealed wit h "O" rings at the Inside diameter to
eliminate leakage between the shaft and sleeve.

(Optional: Shaft shall be positively sealed against pumped fluid by means of specially machined shaft sleeves and
Impeller with sockets for use with "O" ring seals against Impeller hubs.) Shaft sleeves shall extend beyond the
packing glands (or mechanical seal flanges).

Bearings: Bearingsshall be single row,deep groov e ball type; the inboard bearing shall be arranged of r radial loads
only. The outboard bearing shall be arranged of r both radial and axial loads. Both bearings shall be grease
lubricated with grease flush through h
t e bearing hous ing (Optional: oil lube). Bearings shall be designed for an
average life of 100,000 hours.

Bearings shall be protected fromliquid entry by means of rubber def


lectors mounted on the shaft and lip seals In
the bearing housings.

Outboard bearing cover shall have a plugged opening for tachometer connection. Bearing housing lubric ation design
must be capable of being changed rf om grease to oil lubrication type without replacement of bearing housing or the
lower pump casing. The out board bearing shall have retaining ring retention.

Base: The pump and dri ver shall be mounted on a common steel base (with optional drip rim). Pump and driver
shall be aligned and bolted In place prior to factory shipment. Final alignment must be performed at the jobsite In
accordance with the stan dardsof the Hydraulic Institute and the pump Installation, operation and maintenance
instructions. Base Is to be grouted to eliminate vibration.

Coupling: A flexible coupling shall be prov


ided between the pump and driv
er. A coupling guard h
sall be furnis hed
over the coupling for protection.

Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.


Project : Capacity: 5000 (US gpm) Frame/Model: Mfr Std

Customer: Total Head: 145 (psi) Elec. Spec.: Ph.

Item No.: 1 Pump Speed: 1775 (RPM) Service Factor:

Quote No. : US-1817-88 Impeller Dia.: 19,99 (inch) Rotation: Clockwise


Pump Model: Peerless - 10AE20 Power: 600 (hp) Enclosure/Type:
Date : Monday, 23 de April de 2018
Page No : 8
Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.
Project : Capacity: 5000 (US gpm) Frame/Model: Mfr Std

Customer: Total Head: 145 (psi) Elec. Spec.: Ph.

Item No.: 1 Pump Speed: 1775 (RPM) Service Factor:

Quote No. : US-1817-88 Impeller Dia.: 19,99 (inch) Rotation: Clockwise


Pump Model: Peerless - 10AE20 Power: 600 (hp) Enclosure/Type:
Date : Monday, 23 de April de 2018
Page No : 9
Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.
NOZZLE LOADING MAX IMUM FORCES & MOMENTS*
* The pump suction and discharge
piping must be restrained and
12 INCH SUCTION FLANGE supported near the pump to avoid
application of forces and
PLAN VIEW OF FEET moments to pump casing.
125 LB ANSI FLG DRILLING
22,00
250 LB ANSI FLG DRILLING
4,00
10 INCH DISCHARGE FLANGE
125 LB ANSI FLG DRILLING
11,50 250 LB ANSI FLG DRILLING
26,00 SOME HOLES MAY BE TAPPED

11,50 1,00 DIA 4 HOLES 3000


996 2496 996 3000 6000
930 2330 930 2500 5000 2500
DETAIL - SHAFT END 4430 11103 4430 4068 8135 4068
0.625 INCH 4137 10364 4137 3390 6779 3390
8,50 8,50
A-A VIEW FROM DRIVER END A-A VIEW FROM DRIVER END

0.3125 INCH LH ROTATION (CCW) RH ROTATION (CW)


46,50
2,50 26,00 26,00
10AE20 22,00 23,00 2,50 20,50
AIR VENT

5,00 5,00
1,25 1,88
3,75 3,75

35,38
11,00
14,00 19,50
20,75
23,00

DISCHARGE FLANGE 1,25 DISCHARGE FLANGE

45,00
1/4" NPT GAGE CONNECTION 1/2" NPT BRACKET
SUCTION FLANGE SUCTION AND DISCHARGE DRAIN 2 PLACES
FAR SIDE ONLY 2000 LB 909 Kg PUMP WT

Dimensions in (inch)

Project : Capacity: 5000 (US gpm) Frame/Model: Mfr Std

Customer: Total Head: 145 (psi) Elec. Spec.: Ph.

Item No.: 1 Pump Speed: 1775 (RPM) Service Factor:

Quote No. : US-1817-88 Impeller Dia.: 19,99 (inch) Rotation: Clockwise

Pump Model: Peerless - 10AE20 Power: 600 (hp) Enclosure/Type:


Date : Monday, 23 de April de 2018
Page No : 10
Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.
SUCTION

DIESEL ENGINE

ELECTRIC MOTOR

RH ROTATION
DISCHARGE CLOCKWISE

10AE20

Dimensions in (inch)

Project : Capacity: 5000 (US gpm) Frame/Model: Mfr Std

Customer: Total Head: 145 (psi) Elec. Spec.: Ph.

Item No.: 1 Pump Speed: 1775 (RPM) Service Factor:

Quote No. : US-1817-88 Impeller Dia.: 19,99 (inch) Rotation: Clockwise

Pump Model: Peerless - 10AE20 Power: 600 (hp) Enclosure/Type:


Date : Monday, 23 de April de 2018
Page No : 11
Grundfos - RAPID v8.25.9.1 (Windows 7) - 06th March 2012.