2007.04 update
150W Single Output Switching Power Supply S-150 series
Features :
AC input range selectable by switch
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 25KHz
2 years warranty
SPECIFICATION
MODEL S-150-5 S-150-7.5 S-150-9 S-150-12 S-150-13.5 S-150-15 S-150-24 S-150-27 S-150-48
DC VOLTAGE 5V 7.5V 9V 12V 13.5V 15V 24V 27V 48V
RATED CURRENT 30A 20A 16.7A 12.5A 11.2A 10A 6.5A 5.6A 3.2A
CURRENT RANGE 0 ~ 30A 0 ~ 20A 0 ~ 16.7A 0 ~ 12.5A 0 ~ 11.2A 0 ~ 10A 0 ~ 6.5A 0 ~ 5.6A 0 ~ 3.2A
RATED POWER 150W 150W 150.3W 150W 151.2W 150W 156W 151.2W 153.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 180mVp-p 180mVp-p 180mVp-p 180mVp-p 240mVp-p 240mVp-p 240mVp-p
OUTPUT VOLTAGE ADJ. RANGE 4.5 ~ 5.5V 6 ~ 8.3V 8 ~ 10.4V 10.6 ~ 13.2V 12 ~ 15V 13.5 ~ 16.5V 21 ~ 28V 24 ~ 30V 43 ~ 53V
VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LINE REGULATION 0.5% 0.5% 0.3% 0.3% 0.3% 0.3% 0.2% 0.2% 0.2%
LOAD REGULATION 0.5% 0.5% 0.3% 0.3% 0.3% 0.3% 0.2% 0.2% 0.2%
SETUP, RISE TIME 100ms, 50ms at full load
HOLD TIME (Typ.) 28ms at full load
VOLTAGE RANGE 88 ~ 132VAC/176 ~ 264VAC selected by switch 248 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 78% 80% 80% 82% 83% 84% 85% 86% 87%
INPUT
AC CURRENT (Typ.) 3.2A/115VAC 1.6A/230VAC
INRUSH CURRENT (Typ.) COLD START 35A
LEAKAGE CURRENT <3.5mA / 240VAC
105 ~ 150% rated output power
OVER LOAD
Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION
5.75 ~ 6.75V 8.63 ~ 10.13V 10.35 ~ 12.2V 13.8 ~ 16.2V 15.53 ~ 18.2V 17.25 ~ 20.3V 30 ~ 34.8V 31.1 ~ 36.45V 55.2 ~ 64.8V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP. -10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT 0.03%/ (0 ~ 50
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS UL1012, UL60950-1, TUV EN60950-1 Approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
(Note 4) Compliance to EN61000-3-2,-3
HARMONIC CURRENT
EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A
MTBF 286.7K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION 199*110*50mm (L*W*H)
PACKING 0.8Kg; 16pcs/13.8Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
NOTE
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
192
5 172
100
6
12
3.5
1
2
9.5
4
110
97
5
8.2
6
5-M3
7
37
199
6 190.5
6.5
12
16.5
3.5
24.5
3.5
20
50
25
3-
M3
20 159
Ta=25
32 350
100
OUTPUT RIPPLE (mVp-p)
2 28 300
OUTPUT VOLTAGE (V)
80
24 250
1
1 S-150-5~12 CONVECTION
60 2 S-150-15~48 CONVECTION 20 200
S-150-5~12 FORCED AIR
LOAD (%)
16 150
40
12 100
20
8 50
I/P:230VAC SPEC:20mS
10 HOLD UP TIME E: 31.3mS P
O/P:FULL LOAD
NO TEST ITEM TEST CONDITION / SPECIFICATION RESULT VERDICT
I/P:230VAC SPEC: A:78% A:79.58%
O/P:FULL LOAD B:80% B:82.71%
C:80% C:83.17%
D:82% D:83%
E:83% E:82.97%
11 EFFICIENCY F:84% F:84.35% P
G:85% G:85.76%
H:86% H:85.997%
I :87 % I :86.222%
A:129%
B:125%
C:120%
D:129%
I/P:230VAC SPEC: 105%~150% E:125%
OVER LOAD
12 O/P:TESTING F:125% P
PROTECTION
G:130%
H:130%
I :142%
I/P-O/P: 500VDC/100MOhms
SPEC:
MIN. E: O/P-FG >100MOhms
INSULATION I/P-FG: 500VDC/100MOhms
15 I/P-O/P >100MOhms P
RESISTANCE MIN.
O/P-FG: 500VDC/100MOhms I/P-FG >100MOhms
MIN.
EFT TEST:
F: CRITERIA A OK P
EN50082-1 IEC1000-4-4
17 EMS TEST
SURGE TEST:
F: CRITERIA A OK P
EN50082-1 IEC1000-4-5
S-150-
20010226 PASS SAM MAX LIN
13.5,27,48