B-Track Features

Rugged Duty Actuators

Key Features Standard Models


• Weather-tight sealed K2vl, K2, K2x, K2ac, K2xac
• Patented in-line load transfer Option Models
• Heavy wall rod and cover tube K2Pl/K2xPl Threaded rod connection Nitrotec®
• High performance motors K2JS/K2xJS allows optional end fittings. treated end
fitting for
• Up to 2,800 lb. (12455 N) capacity K2RA superior
• Speeds up to 2" per second Hydraulic Cylinder type strength and
Rod Wiper Seal with corrosion
High strength aluminum gear integral extension rod resistance.
box provides maximum heat bearing support for
Ball bearing, Bronze
dissipation. High strength smooth operation and
or Delrin® screw nut
stainless thru-bolt fasteners high side load capability.
configurations
Efficient gear design provide high load capability.
provide broad load
minimizes motor bearing O-ring sealed and gasketed
and performance
load. Gear materials for washdown use.
capability.
selected for high load
Bi-directional
impact and durability.
holding brake
Gear profile optimized for
standard on K2x
quiet operation. High
models.
performance synthetic
lifetime lubes used
throughout.
Unique screw end
bearing guide provides
smooth extension operation,
high side load capability
and aids in screw
re-lubrication. (Patented)

Nitrotec® treated steel


extension rod provides
40% stronger cross
section compared to
competitive products.

Heavywall extension tube has 30%


stronger cross section compared to
competitive products.

Optional electronic control module


with integral electronic stroke
limits and power connections.
Heavy Duty, Sealed Double Ball Adjustable torque limit option.
Bearing Motors For more information see Controls
Integrated • Auto reset thermal protection Section.
manual Mechanical torque • Easy field replacement
override limiter for end of stroke • 12, 24, 48 or 90 volts (vdc) available
– standard and overload protection. (others available on request)
• Standard Packard 56 connector,
Patented in-line design transfers loads to the end
others available
fitting via ball bearing screw pivot. Efficient load
• Washdown sealed
transfer reduces noise and current draw.
• Solid mount pinion gear
Nitrotec® treated end fittings with integral O-ring seals • Lifetime bearing lube
for superior weather and corrosion resistance.
6 available mounting orientations.

22 www.thomsonlinear.com
B-Track Configurator

How To Select
Step 1 – Determine Load and Stroke length requirements Step 6 – Select Nut Type
Use the Quick Selection guide to identify the model family that Select nut for unit selected. (K2x are all ball bearing).
will provide the load capacity and stroke length needed for your
application. Step 7 – Select Stroke Length
Choose standard lengths from chart. For special length
Step 2 – Determine Gear Ratio consult factory.
Select gear ratio from performance charts for allowable current
draw and needed load. Step 8 – Select end fitting orientation
Leave blank for standard orientation.
Step 3 – Identify motor type and voltage
Select DC motor and motor voltage.

Step 4 – Motor Type Important Unit Restrictions


Select M for ignition protected motor (12 VDC only). Side loading and shock loads must be considered in actuator
Select needed motor voltage. applications. Side loading and cantilevered mounting should
be eliminated through proper machine design. Side loading
Step 5 – Confirm the application Duty Cycle will dramatically reduce unit life. While actuators can withstand
At full load capacity, actuators have a 25% duty cycle. Duty limited shock loads, it is recommended that shock loading be
cycle is the amount of ‘on-time’ compared to cooling time. A avoided wherever possible. (See page 71)
unit that runs for 15 seconds should be off for 45 seconds.

B-Track Configurator

K2x P1.x G20 – 12V M – BR – 04 – R120

Actuator Model No. Nut Type* Stroke Length Base Fitting


Gear Ratio
K2x Blank– K2x 04 – 4.00 (100 mm) Alignment
K2 G30 = 30:1 BR – Bronze Nut 06 – 6.00 (150 mm)
G20 = 20:1 Blank– Standard
K2vl BRL – Bronze Nut - Long 08 – 8.00 (200 mm) R30 – 30˚ Fitting
G10 = 10:1 DN – Delrin® Nut 12 – 12.00 (300 mm)
G05 = 5:1 R60 – 60˚ Fitting
18 – 18.00 (450 mm) R90 – 90˚ Fitting
*BRL matches K2x 24 – 24.00 (600 mm)
pin to pin R120 – 120˚ Fitting
R150 – 150˚ Fitting
Motor Voltage
12V – 12 volts
90 ° =R90
Control Model 24V – 24 volts
120 ° =R120
P1.x Fixed Limit Switch 36V – 36 volts
P2.x Position Feedback 48V – 48 volts
EP1.x Adjustable Limit 60 ° =R60 150 °= R150
Switches 90V – 90 volts
RP Low Switching
115V – 115 volts 30 ° =R30
(K2vl Not Available)
230V – 230 volts
Note: See control pages for full
listing of model numbers.
STANDARD

Motor Type
M – Ignition Protected Motor
For standard motor, leave blank.

Scan to watch!
Linear Actuator Basic Selection Video
https://p.widencdn.net/ydtpk6 CL CL LOCATION
OF CLEVIS PIN

www.thomsonlinear.com 23
B-Track K2
Rugged Duty Actuator DC Motor Acme Screw
Features
• Protective coatings and O-ring seals
throughout
• Patented in-line load system
• Hybrid Acme style nut and screw design,
no brake needed
• Ball detent over­load clutch
• Stroke lengths 2 to 24 inches
(50 to 600mm)
• Load capacities up to 1500 pounds
Shown with optional (6672 N)
adjustable limit switch feature • Speeds up to 2.7 inches
(68.58 millimeters)/sec. travel
• Thermal overload incorporated
Up to 1,500 lbs. (6672 N) Rated Load into the motor
Up to 2.7 in. (68.58 mm)/sec. Travel Speed • Heavy wall construction
• Double ball bearing motors
The K2 is the base model in the B-Track family. It incorporates a patented • Heat treated gears
in-line load transfer design which provides high load capability for rugged- • Rugged extension rod bearing support
duty use, efficient power use, compact package size, excellent corrosion • Optional 90 vdc motor for use with
and washdown protection, and high performance synthetic lubrication for SBC-AC control (IP54)
life, all at an affordable price. • Custom mounting options available

The K2 uses a solid bronze or Delrin® nut with a rolled hybrid Acme style Typical Applications
screw yielding high impact capability and long screw life. Heavy-duty • Heavy duty platform and engine lifts
double-ended ball bearing motors, hardened gears, O-ring seals and an • Deck and implement lifts for tractors and
mobile applications
extension rod bearing system that provides best in class capabilities.
• Table positioning
Now Available Optional Adjustable Limit Switch These easy to use • Wheelchair and scooter lifts
adjustable switches are mounted in a channel on the cover tube with • Bin and tank cover lifts
custom cap for protection. They are easily moved to enable the end-user • Flow gate open/close
the flexibility of setting the stroke length at any position within the full Scan to watch!
stroke capability. Just pop the cap off, loosen the set screw and slide the How to Adjust the Limit Switches for a K2 or
K2X Actuator with External or EP Limit Switches
switch into the desired position. https://p.widencdn.net/imzc9v

Load/Current/Speed/Duty Cycle Operating Environment


• Maximum Static Rating: 3,000 lbs. (13345 N) Static • Ambient temp range: -20° F to +150° F (-29º C to +65º C),
(in-line load) -40º F to +176º F (-40º C to +80º C) Upon Request.
• Refer to performance chart for load/current/speed • Weather resistant enclosure & seals (IP69K Static, IP65
capabilities capable, 250 hour salt spray, 500 hour for paint)
• Stroke Length Tolerance: +/-.06” (1.52 mm) • Normal operating voltage: 10-16 vdc (Ratings are at 12
• Motor is protected with auto reset breaker inside motor vdc Normal.)
housing (temperature/current/time dependent)
Control/Connections
• Overload clutch setting: +25% over rated dynamic load
• 14 gauge stranded lead wires-UL style 1230 w/PVC
• Duty cycle is time/temperature/load dependent,
insulation Class F 105°C
suggested guidelines are:
- 50% max on-time/50% off-time for loads up to 50% of • Lead wires abrasion protected with spiral covering
capability • Use momentary contact double pole/double throw switch
- 25% max on-time/75% off-time for loads between in powering unit for extend/retract operation.
50%-80% of capability (ON)-OFF-(ON) DPDT
- 10% max on-time/90% off-time for loads between • Connectors:
80%-100% of capability - Packard 56 series or Delphi Weather-Pack
(Load/stroke profiles will allow some adjustment - Packard 56 series with 56 series blades
variation from these guidelines.) (#2984883 & #2962987)
- Delphi Weather-Pack series (#121015792 & #12010973)
Upon Request

28 www.thomsonlinear.com
B-Track K2
Speed Performance Graphs Imperial
Current Draw
Measurements*
*Performance Chart Measurements are Nominal

K2G05-12VDC
Load Capacity 300 lbs.Nominal Performance K2G05-24VDC Nominal Performance
For Metric Measurements, see page 30.
K2G05-12VDC Current Draw Speed
K2G05-24VDC Current Draw Speed

25 3 12.5 3

2.75 2.75
20 10
Current Draw - Amps

Current Draw - Amps

Speed - IPS
2.5 2.5

Speed - IPS
15 7.5
2.25 2.25
10 5
2 2

5 2.5
1.75 1.75

0 1.5 0 1.5
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Load - lbs Load - lbs

K2G10-12VDC Nominal Performance K2G10-24VDC Nominal Performance


Load Capacity 600 lbs. For Metric Measurements, see page 30.
K2G10-12VDC Current Draw Speed
K2G10-24VDC Current Draw Speed

25 1.5 12.5 1.5

20 1.3 10 1.3
Current Draw - Amps

Current Draw - Amps


Speed - IPS

Speed - IPS
15 1.1 7.5 1.1

10 0.9 5 0.9

5 0.7 2.5 0.7

0 0.5 0 0.5
0 100 200 300 400 500 600 0 100 200 300 400 500 600

Load - lbs Load - lbs

K2G20-12VDC Nominal Performance K2G20-24VDC Nominal Performance


Load Capacity 1200 lbs. For Metric Measurements, see page 30.
K2G20-12VDC Current Draw Speed
K2G20-24VDC Current Draw Speed

25 0.76 12.5 0.76

0.7 0.7
20 10
Current Draw - Amps

Current Draw - Amps

0.64 0.64
Speed - IPS

Speed - IPS
15 0.58 7.5 0.58

10 0.52 5 0.52

0.46 0.46
5 2.5
0.4 0.4

0 0.34 0 0.34
0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200

Load - lbs Load - lbs

K2G30-12VDC Nominal Performance K2G30-24VDC Nominal Performance


Load Capacity 1500 lbs. For Metric Measurements, see page 30.
K2G30-12VDC Current Draw Speed
K2G30-24VDC Current Draw Speed

25 0.46 12.5 0.46

0.44 0.44
20 10
Current Draw - Amps

Current Draw - Amps

0.42 0.42
Speed - IPS

Speed - IPS

15 0.4 7.5 0.4

10 0.38 5 0.38

0.36 0.36
5 2.5
0.34 0.34

0 0.32 0 0.32
0 300 600 900 1200 1500 0 300 600 900 1200 1500
Load - lbs Load - lbs

www.thomsonlinear.com 29
B-Track K2
Performance Graphs Metric Speed
Current Draw
Measurements*
*Performance Chart Measurements are Nominal

K2G05-12VDC
Load Capacity 1335 NNominal Performance K2G05-24VDC Nominal Performance
For Imperial Measurements, see page 29.
K2G05-12VDC Current Draw Speed
K2G05-24VDC Current Draw Speed

25 76 12.5 76

70 70
20 10
Current Draw - Amps

Current Draw - Amps


Speed - MMPS
64 64

Speed - IPS
15 7.5
58 58
10 5
52 52

5 2.5
46 46

0 40 0 40
0 223 445 668 890 1113 1335 0 223 445 668 890 1113 1335
Load - N Load - N

K2G10-12VDC
Load Capacity 2670 NNominal Performance K2G10-24VDC Nominal Performance
For Imperial Measurements, see page 29.
K2G10-12VDC Current Draw Speed
K2G10-24VDC Current Draw Speed

25 40 12.5 40

35 35
20 10
Current Draw - Amps

Current Draw - Amps


Speed - MMPS

Speed - MMPS
30 30
15 7.5
25 25
10 5
20 20

5 2.5
15 15

0 10 0 10
0 445 890 1335 1780 2225 2670 0 445 890 1335 1780 2225 2670
Load - N Load - N

K2G20-12VDC
Load Capacity 5340 NNominal Performance K2G20-24VDC Nominal Performance
For Imperial Measurements, see page 29.
K2G20-12VDC Current Draw Speed
K2G20-24VDC Current Draw Speed

25 20 12.5 20

18 18
20 10
Current Draw - Amps

Current Draw - Amps


Speed - MMPS

Speed - MMPS
16 16
15 7.5
14 14
10 5
12 12

5 2.5
10 10

0 8 0 8
0 890 1780 2670 3560 4450 5340 0 890 1780 2670 3560 4450 5340
Load - N Load - N

K2G30-12VDC
Load Capacity 6675 NNominal Performance K2G30-24VDC Nominal Performance
For Imperial Measurements, see page 29.
K2G30-12VDC Current Draw Speed
K2G30-24VDC Current Draw Speed

25 12 12.5 12
11.5 11.5
20 10
Current Draw - Amps

Current Draw - Amps

11 11
Speed - IPS

Speed - IPS

15 10.5 7.5 10.5


10 10
10 9.5 5 9.5
9 9
5 2.5
8.5 8.5
0 8 0 8
0 1335 2670 4005 5340 6675 0 1335 2670 4005 5340 6675
Load - N Load - N

30 www.thomsonlinear.com
B-Track K2
Dimensions

in. mm in. mm in. mm in. mm in. mm in. mm


B-Track K2 Stroke 2 51 4 102 6 152 8 203 10 254 12 305
A 8.32 211.3 10.32 262.1 12.32 312.9 14.32 363.7 16.32 414.5 18.32 465.3
Note: Special lengths available

7 6 5 4 3 2 1
in. mm in. mm in. mm in. mm in. mm in. mm
B-Track K2 Stroke 14 356 16 406 18 457 20 508 22 559 24 610
A 20.32 516.1 22.32 566.9 24.32 617.7 29.32 744.7 31.32 795.5 33.32 846.3
Note: Special lengths available

["A"] ±3.18
"A" ±.125 RETRACTED
NOMINAL STROKE IS .091 [2.31]
LONGER THAN ADVERTISED
[78.23±0.38] TOLERANCE IS +.036/-.005 [+.91/-.13]
3.080±.015 [11.43±0.38] [13.46±0.38]
.450±.015 .530±.015
[39.12±0.13]
[18.31±1.52] [50.80 +0.30
0 ] [14.87±0.56]
1.540±.005
[ 28.58 -00.08 ] .721±.060
Ø 2.000 +-.012 .585±.022
.000 .000
Ø 1.125 +-.003 (ROD)

[25.40±0.38]
[148.88±0.43] Ø 1.000±.015
5.861±.017 [ 12.93
12.78]
[109.76±0.30] Ø .509 THRU
.503
4.321±.012 BOTH ENDS WIRES PROTECTED WITH [ 63.5 +0.3
-1.3 ]
BLACK SPIRAL WRAP
Ø 2.50 +.01
- .05
10" [254] LEAD WIRE LENGTH
[24.24±0.46]
CONNECT (+) TO GRAY WIRE .954±.018
& (-) TO BLACK WIRE TO EXTEND
THE ACTUATOR
PACKARD 56 CONNECTOR [177±5.08]
ALL DIMENSIONS ARE NOMINAL 6.969±.200
UNLESS OTHERWISE SPECIFIED
Measurements in inches, metric in brackets.

Friday, October 21, 2005 7:41:48 AM


DRAWN
NAME
TWC
DATE
3/17/2014
BEAR LINEA
CHECKED JRZ 3/17/2014 TITLE
ENG APPR.
DIMENSIONAL OUTLINE
MFG APPR. MATERIAL
PROPRIETARY AND CONFIDENTIAL
Q.A.
THE INFORMATION CONTAINED IN THIS KODIAK ACTUATOR
COMMENTS:
DRAWING IS THE SOLE PROPERTY OF
BEAR LINEAR. ANY
REPRODUCTION IN PART OR AS A WHOLE SIZE PART NUMBER
WITHOUT THE WRITTEN PERMISSION OF C K2 Dimensions
BEAR LINEAR IS PROHIBITED. SCALE 1:1

7 6 5 4

www.thomsonlinear.com 31