You are on page 1of 4
Precision Approach Path Indicator (PAPI) Compliance with Standards FAA: FAA L-880 specification AC 150/5345-28D ICAO: Annexe 14, Volume I, para. 5.3..23 105.3545 NATO : STANAG 3316, Uses ‘The PAPI and APAPI systems using PPL units with either 2.0r3 light channels offer the pilot information enabling him to carry out the approach procedure with the utmost accuracy and safety. Features + With only one lamp in use, the PPL. 400/2 outperforms all lamps PAPI units having two lamps in use. + The use of two lenses in tandom in each ight channel ‘makes the transition fram white to red sharp (never exceeding 3 minutes of arc over the full beam with). + ICAO colorimetry conformity maintained over the whole width of the red beam. * Lenses protected from sandblasting by a hardened front lass. Anti-condensation and antirost treatment of front ales available on request + Long Ife (21000 hours ot full intensity), tungsten halo- gen prefocus lamps ‘Distortion tre, al aluminium construction yet featuring a frangible construction ‘Optimal stabiity obtained by using four mounting logs. + Easy instalation and leveling using purpose made ig and instruments, + Long focal lenath makes adjustment in elevation easy, accurate and stable. + lecuced maintenence. The unit is fully gsketed and femains therefore clean inside. Relamping and replacement of fiter do not require any tools + Condensation water is drained away through wire gauze covered drain holes + No water can accumulate on the cover, so reflections which could constitute @ false optical signal aro eliminated. + Fuly corrosion proof since only aluminium, stainless stee! hardware and optical glass are used «Available in 2amps execution (PPL. 400/2) or amps execution (PPL 600/2) + Best match to obstacie protection surtace. * Tit switch option available A025120 PPL 400/2 PPL 600/2 ADB A Siemens Company Construction Aluminium cover Front glass Front glass gasket Inner lens ( Red filter (7) Filter retainer (*) Specular finish eluminium reflector (*) Lamp holding bracket (*) Prefocus halogen lamp (*) Cover gasket Compression busting (*) or, optional, nipple for flexible conduit (*) 12, 2-core cable with 2-pole plug 13, Folded aluminium housing with lockable latch 14. Outer lens (*) 15. Mounting leg top assembly (4) 16. Differential setting sleeve 17. Mounting flange, breakable coupling and height, adjustable leg assembly (4) 18. Anchor bolts (16) option 19. Aluminium anchoring leg (4) option Bdeevemnena 1 1 * 2 for PPL 400/2; 3 for PPL 600/2 ® Finish j FIG.3 Phosphating and baked polyester electrostatic powder coating, Colours = Cover and breakable couplings: aviation yellow = Other surfaces: black. Stainless stee! naraware. = Legs : anodized aluminium tubing Electrical Supply 6.6 A through 200 W isolating transformers (one per light channeb The unit is supplied with 2 m long cables fitted ‘with 823 two-pole plug. Circuit solecior cabinets allow for the supply of two or more PAPI systems fram one common set of regulators. The complete system of eight units can be fet in two evcuits This solution isthe oniy ‘one giving complete reliabilty, os a fll pattem (either part ‘of start board remains fully operational in the event of one: sicui failing FIG.4 ‘The PAP! configuration as per ICAO is shown in figure 8 ‘The distance "X" may vary from 200 to 600 m depending ‘on ocation of ILS glide path antenna, approach slope ‘angle, most demanding aircraft, otc itis recommended that each unit be installed on a solid concrete foundation. Special care should be taken if the subsoils known to be unreliable ‘The recommended installation 'ses adjustable legs secuted on breakable couplings (em 17 of FIG. 3); the mounting flanges are secured on @ conerete slab flush with the surrounding ground. Tho isolation transformers can be installed ina pit agjacent so or combined with the concrote $1. the pi bing eter manson ora L867 stool base In the case of instalation with anchoring legs, the mount- ing column must be first anchored in the siab using the purpose mede positioning frame (supplied on request. ‘The PAP! shall be installed as close as possible to the ground, After assembly, the excavation should be screened over. All around the units the sol should be screened from any kind of vegetation ‘ADB's technical depertment is et the disposal of con- ‘uactors and users to calculate the correct positioning of the system and to provide guidance and advice for any particuar installation problem. Adjustment of the Beam Elevation : ‘The beam setting is achieved by means of an alidade associated with a precision spirit level (FIG. 4). The ‘mounting legs. fitted with differencial setting Sleeves, allow for very precise and stable elevation adjustment. Complete, delete or modity as necessary. With lamps and cables : PPL 40/2 Net weight 20% arg, In cardboard box 65x 33x 102m | 91 x 39.4 101 cm Gross weight 21kg a7 kg PAPI Configuration FIG. Installation at 3 mamas] St a cence [Eee 3 ginas lame i FG. 6 Dimensions (in mm) a g 1000 (PPL B00) ! arr - a ag £ lee EB sla 4 FIG 7 PPLaoo2 + PPL 600/2 8 Light distribution vert. at 0° horizontal (typical curves) Suggested Specification The PAPI unit will meat or exceed the performance ‘specified (with tit syatch option) by ICAO, Annex 14, Vol. | para. §.3.5.23 to 5.3.5.45 and will be in compliance with FAA L-880 specification. The average intensity in ‘ed light willbe at least 15.000 Ca for a horizontal beam ‘spread -6° to +6" and a vertical angle of 3.5° below tran sition. The transition sector will not exceed 3 minutos of {are over the full bears width, The unit will use one pre- focus halogen lamp rated 200 W per light channel ‘The expected lfe of the lamps willbe not less than 1000 hours at fullntensity. The optical system for each light chanel will consist af a high purity alurninum reflector, 3 red, through-coloured glass fiter and two lenses made of optical lass. Lamps and fiters wall be ‘easily replaceable without need of re-calibration. The PAP! unit will be mounted on four logs fitted with pre- Cision olevation adjustment. The unit will be made from folded aluminium sheet fully protected against corrosion, twill be fully weatherproof. A hardened glass will be [provided in front of the lenses to protect them against ‘sandblast, A set of installation tools and calibration instruments will be supplied with each system. FIG.8 FIG. 20k0d s0kea eo Ked 80 Kee 1 100 Kos “ 3 =) at Sarg 1? Light distribution horiz. at 0° vertical (iypicai curves) FIG. 10 Lamp Performances Lamps: 200 W -66 A prefocus halogen - Pk 30 ¢- 1000 hours ‘ated life at full intens:ty (one per ight channel NB: This cat leafiet cance end eplacs cat. leaflet A02 5130 N.V. ADB S.A, Leuvensesteenweg, $85 -B 1930 Zaventem - Belgium Tel: 32/2/722.17.11 - Fax : 32/2/722.17.64 - Telex : 22154 Companies in France, U.K and U.S.A. - Agents all ever the world ADB A Siemens Company '5 PA 05065 Dispo 21649 SEX 71856 g '

You might also like