RELACAO DE CARGA — DEMANDA aTDE pescrigso. =| | POT. UNIT KW] POT TOTAL KW | DEM KVA 25 | motor 1 cv 4.13 KW 28.25 KW 20.75 KVA 12 | woToR 2 cv 1.94 KW 23.28 KW 17.28 KVA 15 | motor 3 cv {2.91 KW 43.65 KW 32.70 KVA 10 | MOTOR 5 cv 4.78 KW 47.78 KW 33.70 KVA 07 | woToR 10 cv 9.68 KW 67.76 KW 45.22 KVA 03 | MOTOR 25 cv 22.44 KW 67.32 KW 44.40 KVA TOTAL 278.04 KW 194.05 KVA 280 | LAMPADAS FLUORESCENTE 0.06 KW 11.20 KW 1400 | LAMPADAS FLUORESCENTE 0.02 KW 28.00 KW 300 | LAMPADAS INCANDESCENTE 0.06 KW 18.00 KW 250 walpaoas INCANDESCENTE 0.1 KW 25.00 KW 82 REFLETOR 0.25 KW 20.50 KW 87 Rehlevon 0.4 KW 22.80 KW 250 | TOMADAS. 0.1 KW 25.00 KW 150 | TOMADAS 0.3 KW 45.00 KW 80 | TONADAS 0.5 KW 40.00 KW 20 | TOMADAS 1.5 KW 30.00 KW 10 | TOWADAS 4.0 KW 40.00 KW TOTAL 305.50 KW 164.75 KVA 25 | AQUECEDORES 2.0 KW 50.00 KW 19.00 KVA 22. | cHUvEIROS 5.4 KW 118.80 KW 46.33 KVA 15 | MAQUINAS DE SOLDA 10.0 KVA 150.00 KW 57.00 KVA TOTAL 902.34 KW 481.13 KVA MEMGRIA DE CALCULO PARA AJUSTE AJUSTE DE PROTEGAQ SECUNDARIA DADOS ELETRICOS ; 01 - POTENCIA INSTALADA ‘QTDE| POTENCIA (KVA] IN(A) INDIV, IN(A) TOTAL, 4 75 3.14 12.56 mea 7125 471 9.42 2 150, 628 72.58 TOTAL] 82s [3456] 02 ~ DEMANDA DEMANDA A SER CONTRATADA: 185 KW 03 - PROVETO DE LIGACAD . 8 TRASFORMADORES 4X 75 KVA ~ 13,8 KV - 220v 2 X 1125 kVA ~ 13,8 kV - 220v 2 X 150 KVA ~ 13,8 KV - 220V 04 - CALCULD DA CORRENTE NOMINAL - ¢ In >. In = ( DEMANDA (KW) / 1.73 X 138 CKV > xX 092. tes kW / (173X 138X092 > = 842A 05 - C4LCULO DA CORRENTE DE PARTIDA - ¢ Ip > Ip = MXIn Ip = Mx 842 = 9264 06 - CALCULO DA CORRENTE DE MAGNETIZACAD DOS TRAFOS - ¢ Im) Im = 8 X Ini DO TRAFO DE 150 KVA + In DO TRAFO 150 KVA + In DOS 2 TRAFOS 1125 KVA + In DOS 4 TRAFOS 75 KVA Int = PCKVA) = 150KVA = 628A v3 xv 173 x 138 In@= PCKVA> = 125KVA = 4210 va xv 173 x 138 In3= PCKVAD = 75 kVA 314 8 “VaxV (173 x8 IM=B X 628+ 628+ 042+ 1256 = 7754 para + = 01 seg 07 - CALCULO DO PONTO ANSI DO TRAFO ¢ 1 ANSI > 1 ANSI CORRENTE M4XIMA QUE 0 TRANSFORMADOR SUPORTA DURANTE UM PERIODO DEFINIDO DE TEMPO, SEM SE DANIFI| 1 ANSI DE FASE = ¢ 10072 %> X IN DO TRANSFORMADOR 1 ANSI DO NEUTRO = 058 X I ANSI DE FASE 07 - CALCULO DO PONTO ANSI DD TRAFO ¢ I ANSI > 1 ANSI CORRENTE MAXIMA QUE 0 TRANSFORMADOR SUPORTA DURANTE UM PERIODO DEFINIZO DE TEMPO, SEM SE DANIF 1 ANSI DE FASE = ¢ 100 / 2%) X IN DO TRANSFORMADOR 1 ANSI DO NEUTRO = 058 XI ANSI DE FASE ONDE Z % € A IMPEDANCIA PERCENTUAL DO TRANSFORMADOR PARA TRANSFORMADORDE"SOO KVANINZ 9S PARA TRANSFORMADOR DE 300 KVA Z%= 5% PaRA TRANSFORMADOR DE 1S0KVA 2% = 5% PARA TRANSFORMADOR DE 1125 kVA Z%= 5 % TEMPO MAXIMO 3 SEGUNDOS 1 ANSI DE FASE 10075X 6.28 A I aNsi DE FASE = 20 X 6. 28= 125.64 1 ANSI DE NEUTRO = 058X 125.6 = 72,84 A TRAFD 150 KVA TANS DE FASE 10075X 4.21 A 1 ANSI DE FASE = 20X 4.21 = 84.20 T ANSI DE NEUTRO = 058X 84.2 = 48.844 TRAFO 125 KVA T ANSI DE FASE 10075X 3.14 A I ANSI DE FASE = 20X 3.14 = 628A I ANSI DE NEUTRO = 058X 62.8 = 36.42 — TRAFO 75 KVA 08 - DEFINIGAD DA RELAGAD DE TRANFORMAGAO DOS TC S ‘A CORRENTE DE CURTO CIRCUITO TRIFASICA NO PONTO DERIVAGAD DA REDE CEMIG = 3500 A RECOMENDA SE QUE A MAIDR CORRENTE DE CURTO CIRCUITO ¢ TRIFASICO > NAD EXCEDA EM MAIS DE 50 VEZES A Ct DE ACORDO COM AS RELACHES DE TRANFORMACAD PADRONIZADAS, SERAD INSTALADOS TCS DE 75/5 09 - DIMENSIONAMENTO DO ELOS FUSIVEIS PRIMARIO FUSIVEL DE PROTEGAD DO RAMAL DE LIGAGAO DE ACORDO COM A ND 5.3 PARA DEMANDA DE 185 KW DEVERA SER INSTALADO CHAVE FUSIVEL DE 15 KV 71 KA It FUSIVEL DE PROTEGAD DOS TRAFO 150 kVA 8 K FUSIVEL DE PROTEGAO DOS TRAFD 1125 KVA 6 K FUSIVEL DE PROTECAD DOS TRAFO 75 KVA SH 10 - AJUSTE DO RELE RELE DE PROTECAD FOI ADOTADO O RELE URPE 7104 ¢ V 21 / 311 > DA PEXTRON FUNGAO INSTANTANEA SO / SON PROTEGAD DE SOBRE CORRENTE INSTANTANEA FUNGAD INSTANTANEA Si / SiN PROTECAO TE SOBRE CORRENTE TEMPORIZADA 4 FUNG&D INSTANTANEA SO 4 UNIDADE INSTANTANEA SO SERA AJUSTADA A UM VALOR SUPERIOR ¢ MAXIMO 5% > ‘A CORRENTE DE MAGNETIZAGAO CI RUSH > QUE € IGUAL A 77.5 4 ENTAD SERS AJUSTADA PARA CORRENTE PRIMARIA DE 81 A A FUNCAO INSTANTANEA SON. ‘A UNIDADE INSTANTANEA SO N SERA AJUSTADA EM 33 % DO VALOR DA UNIDADE INSTANTANEA SO 81 X 33 % = 267, A FUNGAD TEMPORIZADA Si FOL ESCOLHIDA A CURVA DO RELE COM CARACTERISTICA EXTREMAMENTE INVERSA, AJUSTE DA CORRENTE DE PARTIDA (IP >= 9. 26 A @ FUNGAD TEMPORIZADA Sl N AJUSTE DA CORRENTE = 33 % DE IP 926 x 33 % AJUSTE DE TEMPO DE FASE T= KX DIAL / CIP INST / IP TEMP >? 1 Teexo1s@ s9.e6F -1 T=0,1 Seg DIAL = 0.1 AJUSTE DE TEMPO DE NEUTRO kX DIAL / ¢ IP INST NEUTRO / IP TEMP NEUTRO>® - 1 80 xX 01/@6.7 73.06% -1 20,1 Seg ~ DIAL 1 PARAMETROS € RESPECTIVOS AJUSTES RTC = 15 | inDICE DESCRIGAO ‘AJUSTES| [Ip Corrente de partida de tempo dependente de fase [3.26K | Curva __|Tipo de curva de atuago de fase El Dt___[Ajuste de tempo de fase e neutro OF TDef.__ [Corrente de partida de tempo idependente de fase MAXIMA | T. Def. Tempo da unidade independente de fase 2408 —L'inst._— [Corrente da unidade intantanea de fase = BIA |. partida -N Corrente de partida de tempo dependente de neutro 3.064, Curva [Tipo de curva de atuagde do neuro EI Corrente de partida da unidade de tempo |__| Bef. independente de neutro noes [_-T.Def.__ [Tempo da unidade dependente de neutro [240s]

You might also like