You are on page 1of 9
(»)” EBYTE E820-DTU (212-433L) This manual may be modified based on product upgrade, please refer to the latest version, All rights to interpret and modify this manual belong to Chengdu Ebyte Electronic Technology Co, Ltd. Version Date Description ssaed by 1.00 20180802 Inia version usa 12 2n20/05/28 au Content wo 2 6 2.1 General parameters. 6 22 Size and interface description. - 7 23. Reset button description, 9 2.4 Al,A2 indicator description, 9 2.9 DIP switch description. 9 3. Configuration, 9 3.1 Parameter configuration steps. 1 3.2 Parameter and button definitions. : u 4. ModBus. u 4.1 Register seting table. JSR! ABLE Features (© Htsupports 2-channel analog quantity input. default current checks © Hesupports 2-channel analog quantity output, default curent output ‘© fesupports remote transmission of analog data via 433MiHz band: © Htsupports analog quantity following, controling & collecting ‘© Itsupports four operation modes: flowing TX, following RX, controlling & collecting and configuration, © Contvoling & collecting mode adopts Modbus RTU protocol data processing: © ttsupports Reset with button, configure device address and reset to factory settings by long-pressing for 5s © Builtin watch-dog enables super stability: © 3 double-color indicators indicating operating modes: © The powor source features good over-current, over-voltage, reverse connection protection functions. 1. Quick Start 1.1 Connection 1.1.1 RS485 connection RS485 Connection Chart external power 8~28V RS485_B ‘O} RS485_A User RS485 device 1.1.2 Analog quantity input connection TEE eo ‘Analog Input Connection 1.1.3 Analog quantity output connection User device to O aot+ be controlled Current input. -}——O AO1- Analog Output Conenction 114 Following Preparing two units of £820-DTU (212-433U), uit A and unit B. Make sure parameters of both units are totally same (default parameters). Set ‘operating modes by changing postions of dip switches. Set unit Aas folowing TX mode and unit 8 as following RX mode. Unit A adopts analog input connection and unit B adopts analog output connection. Then unit A and unit & could realize following function. Unit A, the tansmittr, M1-0, MO-1, repower it on after configurating, Unit 8 the receiver, Mi=1, MO=0, repower it on after configurating, For example, channel 1 of unt A collects 10mA analog quantity, then channel 1 of unit ® outputs 10mA analog quantity, if channel 1 of unit & inputs nothing, then channel 1 of unit B outputs nothing. When unit A transmits data for one time, indictors A1 and A2 biink for one time with blue light, when unit 8 receives data for one time, At and A2 blink for onetime with green light. 4 ( FF following Ge) — st eo toma 820-DTU (unit A) £820-DTU 10mA (unit B) "Notes: Under following mode, the analog output interface of unit A does not work, and the analog input interface of unit does not work. 1.2 Controlling & collecting Prepare one unit of E820-DTU (212-4331) and one unit of E90-DTU, the devices adopt Modbus RTU protocol. Please chack the following RF Channel Table and Wireless Response Time Table. Configure the E90-DTU and E820-DTU (212-4331) to same parameters, Configure the operating modes of E820-DTU (212-433) by changing positions of the dip switches. Controlling & collecting mode, M1+0, M0=0, repower it on after configurating. Under collecting mode, for example, E90-DTU could read the input value of channel 1 of £820-DTU (212-4331) with ‘command 01 03 00 11 00 01 D4 OF. Ifthe input value is 10mA, the ideal value returned should be 01 03 02 27 10 A2 78. 0x2710H could be altered into 10000D, which represents 10.000mA. 2, E90-DTU could read the output value of channel 1 of E820-DTU (212-4331) with Under controlling mode, for exampl: command 01 06 00 41.27 C3 E2. ri) sy —| Ao 4 8232 gna R505 sign, > | E90-pTu 820-DTU analog signal | Ait & : Tene signal « 2. Product Introduction E820-DTU (212-4331) is a remote controlling device supporting analog quantity following, controlling and collecting. Under controlling and collecting mode, it supports Modbus RTU protocol. This product features easy-to use, it can be integrated Into user systems so as to realize remote wireless controlling via 433MHz band. 2.1. General parameters Item Index ‘Standard band 433MiHz RF parameters ‘Tk power 1w ‘Size (H*W*D) 124*105*25 Weight 9 Operation temperature | -20'C -+70°C ‘Storage temperature -40'C -+85°C Operation humidity 5% ™ 95% Hardware parameters | Storage humidity 1%" 95% Operation voltage av~28v Current collecting range | OmA~20mA. Current output range | OmA~20mA. Precision 0.2% Data interface S485: 9600bps Software parameters Operation mode Following TX, following RX, Controlling & Collecting, Configuration Configuration command ‘Modbus RTU 2.2 Size and interface description 105 < > = e = a cry cry a aa wast poy| t+. Analog Converter... sor wee & AM AOt De )) Al2+ AO2+ y [822 atz- is ‘AO2- ww) | eset @) mo EBYTE 4 [e3| 485-A E820-DTU w= Els J, y ll0°2) vec o00 ant'Y V7) <,>| PWRIRST At 2 + Coz Cs <> 261 [poo0) ’ 1@ 9) Vi a am Analog Converter ae aa 4 = Entre 495.4 £820-DTU ao 1/8 ee et ee GI oY HD a a a ee aie. a j a lente | EN 2 as Lepisiaslaonl | aneteli a nas ean ae | Nae RR RR TE: 4 cs SS ni a = ox dos ob oe ea : ey nae rT 2 _ ae: RS NNR 7 oa eau peniteameae | Powe a ee SS enn erties | Cl cdl imate pos ibcsaionacal a a TF dan TAK nr | Ber ec bn pee tao pes tere 2 : dan THAN | ear ne De pe Ten pee ta oe) 5 ia abe in ™]bPeWiah Mode eon wane (00.30 = ee: | Dalen saperdianel as ndetb 7 = ee eg Le eT 7 a, | Ameer epaananel gate | een RO i ais eapceeet sient | Ang cpeincialph Eos aapetin Si. Notes: Ground: suggest to ground the device case. RS485: RS485 interface will only be used when configuring parameters under configuration mode. 2.3 Reset button description Long-pressing for S seconds, RST indicator blinks for one time once reset successful. (only valid under following RX, controlling & collecting, configuration modes, only reset the device address as OxO1H) 2.4 A1, A2 indicator description Under following or controlling & collecting mode, Ai and A2 are used to indicate the wireless data transmission, Under following TX mode, when transmitting data, Al and A2 blink for one time with blue light; under following RX mode, when receiving data, Al and A2 blink for one time with green light. Under controlling & collecting mode, when channel 1 has data interaction, A1 blinks for one time with blue light, when channel 2 has data interaction, A2 blinks for one time with blue light. 2.5 DIP switch description Select operation mode by changing DIP switches position (Mi & MO, at lower position means “O"), effect after repowered. ‘Mode Type ma 0 Defirition| controling & Mode 0 ° ° Wireless consoling & collecting functions Collecting Moe 1 rollowng 1x v 2 rangmiter, under fotowang mode Mode 2 Following PX 1 ° Receiver, under following mode Mode Configuration 1 4 For configuring parameters with upper computer 3. Configuration

You might also like