TopWorx 

Valve Control Solutions info.topworx@emerson.com
over HART transmiter

For more information please  •Visit our Partner Website (members.topworx.com) or •Visit the Online Configurator (configurator.topworx.com)

DX‐Series
Enclosure Bus/Sensor Area Classification Visual Display Shaft Conduit Entries
DXP Tropicalized Bus Network 0 Intrinsically safe G Standard 90° S 1/4" DD DXP/DXS
Aluminum AS AS‐Interface w(2) SPDT GO (Bus/sensor cannot be Green OPEN, 316 stainless steel (Metal Conduit Entries)
Switches AS, DN, ES, PB, or _X; Red CLOSED E (2) 3/4" NPT
(Area class cannot be 0) Requires appropriate
DXR Composite Resin I.S. barrier) N NAMUR
("S" Silicone *FF Foundation ‐ North America R Standard 90° 316 stainless steel 4 (2) 3/4" NPT
O‐Rings only; Fieldbus w/ 0 ‐10K Pot Class I Div 1&2 Green CLOSED, (2) 1/2" NPT
Stainless steel Groups A, B, C, D Red OPEN
conduit entries) *FL Foundation Fieldbus w/(2) Type 4, 4X (for Model DXR)
(Area Classification SPDT GO Switches ‐ ATEX/IECEx M (2) M20
0 only available with Zone 0 B 90° Black OPEN,
ATEX/IECEx approvals) *FP Foundation Fieldbus w/(2) II2GD, T6/T4 Yellow CLOSED
SPDT GO Switches and Ex ia IIC 3 (4) M20
0‐10K Pot Ex tb IIIC, IP66/67
DXS 316 (Foundation Fieldbus) Y 90° Yellow OPEN,
Stainless steel DN DeviceNet w(2) SPDT Zone 1, Ex ib IIC T4, IP67 Black CLOSED 6 (4) 3/4" NPT
GO Switches
(Area class cannot be 0)
1 Explosionproof / 1 3 way, 90°
PB Profibus w/(2) SPDT GO Flameproof (DXP/S only) L Port DXR
Switches (Area class cannot ‐ North America P (2) 1/2" NPT
be 0) Class I Div 1
Groups C, D;
Partial Stroke Test Class I Div 2, 3 3 way, 90° E (2) 3/4" NPT
ES ESD/PST Groups A, B, C, D. T Port
Module w/GO Switch (Groups A & B must be
(Area class cannot be 0) hermetically sealed) M (2) M20
Type 4, 4X,
SH HART transmitter w/ D2  ‐ ATEX/IECEx 5 3 way, 90°
ESD/PST 2 GO Switches Zone 1 T Port
II2G, II2GD, T6/T4/T3
SS HART transmitter w/ D2  Ex db IIB+H2
ESD/PST 4 GO Switches Ex tb IIIC IP66/67
(O‐Rings must be S for 7 3 way, 180°
GO™ Switches DUST certification) T Port 3 position
L2 (2)GO Switches
SPDT hermetic seal
L4 (4)GO Switches 2 Non‐incendive
SPDT hermetic seal(not avail (Bus/sensor must be 9 3 way, 180°
able with pilot) L, Z, P, E, AS, FF,_X, _H, _E T Port 3 position
Z2 (2)GO Switches or DN)
DPDT hermetic seal ‐ North America
Z4 (4)GO Switches Class I Div 2
DPDT hermetic seal, (not Groups A, B, C, D; S Stainless Steel 
available with pilot) Class II Div 2 Indicator
Groups F,G
Mechanical Switches ‐ ATEX (DXP/S only)
(Area class cannot be 2, DXR with II3G Ex nA nC tb, IP66/67
G approval not available with pilot) (O‐Rings must be S for
M2 (2)Mech SPDT DUST certification)
M4 (4)Mech SPDT
M6 (6)Mech SPDT
T2 (2)Mech DPDT G General Purpose
K2 (2)Mech SPDT Type 4, 4X
gold contacts (not available with DXR 
K4 (4)Mech SPDT with mechanical switches)
gold contacts

Inductive Sensors C Flameproof
E2 (2) p+f NJ2‐V3‐N (DXS not available with
inductive NAMUR valve; Conduit entries must
E4 (4) p+f NJ2‐V3‐N be E or M) ATEX/IECEx
inductive NAMUR II2G, II2GD, T6/T4/T3
B2 (2) NJ2‐12GK‐SN Ex db IIC
V2 (2) NJ3‐18GK‐S1N Ex tb IIIC IP66/67
F2 (2) NJ2‐12GK‐N
J2 (2) NJ2‐11‐SN‐G
N2 See page 48 for full list of D Dual Certification
options available User may select
i.e. DXP‐N20GNMB00000N003 Intrinsically Safe (EX ia)
above part number incorporates OR For complete information
(2) SJ3.5‐N switches Explosionproof (Ex d) on certification options,
by stamping nameplate go to www.topworx.com
4‐20mA Analog Output (must have region code B and download the applicable
(Available with 2‐switch without pilot/spool valve) product certificate.
options only for L,Z,M,K,E,T)
W No approvals;
_X 4‐20mA Type 4, 4X 
transmitter IP66/68

 4‐20mA w/HART 7
(Available with 2‐switches options:
L, Z, M, K, E: switches are separate DI's) * North American approvals
through UL
_H 4‐20mA
transmitter with HART * FF, FL and FP with Area
Classification "0" has an ib
4‐20mA w/HART 7 protection
(Available with 2‐switches that are
communicated over HART: L, M, K)

H_ 4‐20mA
tranmsitter with HART

Example:
LH =  (2) GO Switches
with HART transmitter 

3
‐‐‐ ‐‐ ‐ ‐ ‐ ‐
TopWorx Valve Control Solutions info.topworx@emerson.com

For more information please  •Visit our Partner Website (members.topworx.com) or •Visit the Online Configurator (configurator.topworx.com)

DX‐Series
O‐Rings Pilot Spool Valve Valve Cv Manual Override Regional Certs
B Buna ‐N   Blank   Blank   Blank   Blank   Blank  
  No Pilot device(s) (No Spool Valve) (No Spool Valve) (No Override) (No regional 
cert)
S Silicone   2 1.06 Cv    1 Single Pushbutton  
  DXP/DXS DXP/DXS  (1/4" NPT Ports) Momentary/Latching B InMetro   
1 (1) 24 Vdc pilot, fail A Aluminum   (Area Class
For temperatures below open/closed Hard coat anodized 2 Dual Pushbutton   0, 1 and C
‐40°C Silicone O‐Rings 0.5 W (non‐ I.S.)   (IP65) DXP/DXS Momentary/Latching only)
are recommended   3 3.7 Cv No E2 sensor for I.S.
0.5W (I.S)   (1/2" NPT Ports) T Partial stroke  
  6 316 Stainless steel   (For manual override  test button N CCC Ex  
2 (2) 24 Vdc pilots, fail   (IP65) consult factory) with lockable cover
last position (Sensor ES only) (Not 
  Spool Valve A   available w/Area Class F Fisco  
0.5W (I.S)   DXR C) (DXP/S ‐ Conduit (Bus/Sensor
Spool Valve 6   Entries 4 or 3 only.) must be FF;
  A Aluminum   (DXR Consult factory) Area Class
4 (1) 220 Vac Pilot, 2W,   Hard coat anodized must be 0)
fail open/closed (IP65) DXR
 
5 (2) 220 Vac pilots, 2W,   3 3.7 Cv K KOSHA  
fail last position 6 316 Stainless steel   (1/2" NPT Ports) (DXP/S only)
  (IP65) (For manual override (Area class 1 or
7 (1) 110 Vac pilot, 1.1W,   consult factory) C)
fail open/closed
  Spool Valve A  
8 (2) 110 Vac pilots, 1.1W,   R EAC (DXP/S  
fail last position Spool Valve 6   only)(O‐Rings
  must be B or
P (1) piezo pilot, fail   S, B= Gas
open/closed (FF only) Approved;S
  = Gas/Dust
R (2) piezo pilots, fail last   Approved)
position (FF only)

DXR P PESO (India)  
(Gas approval
1 (1) 24 Vdc pilot, fail only)
open/closed
0.5 W (non‐ I.S.)   T TS (Taiwan)  
 
0.5W (I.S)  
 
2 (2) 24 Vdc pilots, fail  
last position A ANZEx  
  Ex d IIC,
0.5W (I.S)   Ex d IIB+H2
(DXP/S only)
 
4 (1) 220 Vac Pilot, 2W,  
fail open/closed
 
5 (2) 220 Vac pilots, 2W,  
fail last position
  Accessories
7 (1) 110 Vac pilot, 1.1W,  
fail open/closed
Description Part Number Price
  Pneumatic Accessories
8 (2) 110 Vac pilots, 1.1W,   Flow Control, 1/8" NPT (1 per kit) AL‐M20
fail last position Flow Control, 1/4" NPT (1 per kit) AL‐M21  
  Flow Control, 1/2" NPT (1 per kit) AL‐M22
Exhaust Protectors, 1/4" NPT
P (1) piezo pilot, fail   AL‐M32  
 (2 per kit)
Exhaust Protectors, 1/2" NPT
open/closed (FF only) AL‐M33  
 (2 per kit)
  Slip‐Lok, 1/2'' x 1/2" AV‐SLPP
R (2) piezo pilots, fail last   Slip‐Lok, 3/4'' x 1/2'' AV‐SLEP
position (FF only)

‐ ‐ ‐ ‐ ‐ ‐ 4