INTERNATIONALE IEC
INTERNATIONAL 62093
STANDARD Prem iere edition
F irst edition
2005-03
Balance-of-system components
for photovoltaic systems -
Design qualification natural environments
Num6ro de reference
Reference number
CEI/IEC 62093:2005
N umerotation des publications Publication numbering
D epuis le 1er ja n vie r 1997, les p u b lica tio ns de la CEI As from 1 January 1997 all IEC p u b lica tio ns are
sont num erotees â p a rtir de 60000. A insi, la CEI 34-1 issued w ith a desig n atio n in the 60000 series. For
devient la CEI 60034-1. exam ple. IEC 34-1 is now referred to as IEC 60034-1.
Les versions consolidees de certaines publications de la The IEC is now p u blishing consolidated ve rsion s of its
CEI incorporant les am endem ents sont disponibles. Par pub lica tio ns. For exam ple, e d itio n num bers 1.0. 1.1
exemple, les numeros d'edition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, resp e ctive ly, to the base publication,
respectivem ent la publication de base, la publication de the base pub lica tio n in co rp o ra tin g am endm ent 1 and
base incorporant I'am endem ent 1, et la publication de the base pub lica tio n in co rp o ra tin g am endm ents 1
base incorporant les am endem ents 1 et 2. and 2.
Le contenu technique des p u b lica tio ns de la CEI est The te ch nical co n ten t o f IEC p u b lica tio ns is kept
constam m ent revu par la CEI afin q u ’il refle te I’etat under co n stan t review by the IEC, thus ensuring th a t
actuel de la technique. Des renseignem ents re la tifs â the co n ten t refle cts c u rre n t tech no lo g y. Inform ation
cette p ublication, y com pris sa va lid ite , so n t d isp o relatin g to th is pub lica tio n, in cluding its va lid ity, is
nibles dans le C atalogue des p u b lica tio ns de la CEI a va ila b le in the IEC C atalogue o f p ublications
(voir ci-d esso u s) en plus des nouvelles editions, (see below ) in addition to new e d itions, am endm ents
am endem ents e t co rrigenda. Des in form ations sur les and corrigenda. Inform ation on the sub je cts under
sujets â l’6tude et I’avancem ent des trava u x entrepris co n sid e ra tio n and w ork in progress undertaken by the
par le com ite d'etu d e s qui a elabore cette p ublication, te ch nical co m m itte e w hich has prepared this
ainsi que la liste des p u b lica tio ns parues, so n t pub lica tio n, as well as the lis t o f p u b lica tio ns issued,
egalem ent d isp o n ib les par I'in te rm ed ia ire de: is also a va ila b le from the fo llow ing:
Balance-of-system components
for photovoltaic systems -
Design qualification natural environments
A ucune partie de cette publication ne peut âtre reproduce ni No p ari o f th is publication may be reproduced o r utilized in any
utilisee sous quelque forme que ce sort e t par aucun precede, form o r by any m eans, electron ic o r mechanical, in cluding
filectronique ou m & a n iq u e , y com pris la photocopie et les photocopying and m icrofilm , w ithout perm ission in w riting from
m icrofilm s, sans I'accord ecrit de I'editeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembe. PO Box 131, CH-1211 Geneva 20, Switzerland
T e lephone:+41 22 919 02 11 T e le fa x :+41 22 919 03 00 E-mail: inmait@iec.ch Web: www.iec.ch
C O D E P R IX
C om m ission E lectrotechnique Internationale P R IC E C O D E W
IEC International E lectrotechnical Com m ission
M e w a y H a p o flH a » O neK TpoTexHM M ecK aa Kom m ccm *
Pour pax. voir catalogue en vigueur
For price, see current catalogue
- 2 - 62093 © C E I:2005
SOMMAIRE
A V A N T -P R O P O S ................................................................................................................................................6
Annexe A (in fo rm ative ) S euils de com m utation pour les co ntröle urs de charge utilisant
la tension de la b atterie com m e param etre principal pour I’alg orith m e de c o m m u ta tio n ............74
CONTENTS
F O R E W O R D .........................................................................................................................................................7
A nnex A (in fo rm a tive ) S w itching th re sh o ld s fo r ch arge c o n tro lle rs using the b attery
vo ltag e as the m ain p aram eter fo r the sw itchin g a lg o rith m ................................................................75
C O M P O S A N T S BOS DES S Y S T E M E S P H O T O V O L T A IQ U E S -
Q U A L IF IC A T IO N ET ESSAIS D ’E N V IR O N N E M E N T
AVANT-PROPOS
1) La Com m ission E le ctro tech n iq u e Intern a tio n ale (C E I) e st une org a n isa tio n m ondiale de norm alisation
com pos6e de I'ensem ble des com itâs 6 le ctro te ch n iq u es nationaux (C om it6s nationaux de la CEI). La CEI a
pour objet de fa vo rise r la co o peration in te rn a tio n a le pour to u tes les q uestions de no rm a lisa tio n dans les
dom aines de l’6 le ctricite et de l'6 le ctro n iq u e . A cet effe t, la CEI - entre a utres a ctivite s - publie des Norm es
in te rn a tio n a le s, des S p e cifica tio n s techniques, des Rapports tech niqu e s, des S pe cifica tio n s accessibles au
public (PAS) e t des G uides (ci-a p râ s denom m es -P u b lica tio n (s) de la C EI"). Leur e laboration est confiöe â des
com ites d'etudes, aux travaux desquels tout Com ite national in teresse par le su je t traite peut p articiper. Les
org a n isa tio n s in te rn a tio n a le s, g o u vernem entales et non gouvernem entales, en lia iso n avec la CEI, pa rticip a n t
6galem ent aux travaux. La CEI co lla b o re 6 tro ite m e nt avec ('O rganisation In te rn a tio n ale de N o rm alisation (ISO ),
selon des co n d itio ns fixe e s par accord e n tre les deux o rganisations.
2) Les d e cisions ou accords o ffic ie ls de la CEI co n ce rn a n t les q u e stion s techniques reprĞsentent, dans la m esure
du possible, un accord in te rn a tio n a l sur les sujets 6tudi6s, âta nt donnâ que les C om it6s na tio na u x de la CEI
in te re sse s sont representes dans chaque com ite d'etudes.
3) Les P ublications de la CEI se p re se n te n t sous la form e de recom m andations in te rn a tio n a le s et sont agreâes
comm e te lle s par les C om it6s nationaux de la CEI. Tous les e ffo rts raison n a b le s sont e n tre p ris afin que la CEI
s'assure de I'exactitude du contenu tech niqu e de ses p u b lications; la CEI ne peut pas etre tenue responsable
de l'â ve n tu e lle m auvaise u tilisa tio n ou in te rp r6 tatio n qui en est fa ite par un quelconque u tilis a te u r final.
4) Dans le but d 'en co u ra ge r I'un ifo rm ite in te rn a tio n a le , les C om ites nationaux de la CEI s'engagent, dans toute la
m esure possible, â a p p liq u er de façon tran sp a ren te les P u b lica tio n s de la CEI dans leurs p ublications
na tio na le s et râg io n a le s. Toutes divergences entre toutes P ublications de la CEI et toutes p ublications
na tio na le s ou regionales corre sp o n da n te s doivent etre indiquees en term es cla irs dans ces dernieres.
5) La CEI n a pr6vu aucune procedure de m arquage va la n t in d ica tio n d ’app ro b a tio n e t n’engage pas sa
resp o n sa b ilit6 pour les 6quipem ents dâclarâs conform es â une de ses P u blications.
6) Tous les u tilisa te u rs doivent s'a ssure r qu’ils sont en p ossession de la d e rn ie re e d itio n de cette publication.
7) Aucune resp o n sa b ilit6 ne doit âtre im putee â la CEI. â ses a d m in istra te urs, em ployâs, a u xilia ires ou
m andataires, y com pris ses e xp e rts p a rticu lie rs et le s m em bres de ses com ites d'etudes et des C om ites
nationaux de la CEI, pour to u t p re judice cause en cas de dom m ages co rp o re ls et m ateriels, ou de tout autre
dom m age de q uelque nature que ce soit, d irecte ou in d irecte , ou pour su p p orte r les coûts (y co m p ris les frais
de ju s tic e ) et les depenses decoulant de la pub lica tio n ou de l'u tilisa tio n de ce tte P u b lica tio n de la CEI ou de
tou te autre P ublication de la CEI, ou au cre d it qui lui est accorde.
8) L'atte n tio n est a ttirâ e sur les râfâ re n ces norm atives citâes dans cette p ublication. L 'u tilisa tio n de p ublications
referencees est ob lig a toire pour une app lica tio n co rre cte de la presente publication.
9) L’atte ntio n est a ttirâe sur le fa it que ce rta in s des âlâm ents de la prâsente P u b lica tio n de la CEI peuvent faire
I’o b je t de d ro its de p ropriâtâ in te lle ctu e lle ou de d ro its analogues. La CEI ne sa u ra it âtre tenue pour
responsable de ne pas a vo ir id e n tifie de te ls d ro its de propriete et de ne pas a vo ir sig n a le le u r existence.
La N orm e in te rn a tio n a le CEI 62093 a ete e tablie par le com ite d 'e tu d e s 82 de la CEI:
S ystâm es de conve rsio n p h o to vo lta iq u e de l'6 ne rg ie solaire.
82/374/FD IS 82/380/R V D
Le rap po rt de vote indique dans le tableau ci-d essu s donne toute inform a tion sur le vo te ayant
abouti â l'a pp ro b atio n de cette norme.
C ette p ub lica tion a ete redigee selon les D ire ctives IS O /C E I, P artie 2.
62093 © IE C :2005 - 7 -
B A L A N C E -O F -S Y S T E M C O M P O N E N T S
FOR P H O T O V O L T A IC S Y S T E M S -
DESIGN Q U A L IFIC A TIO N N A TU R A L E N V IR O N M E N T S
FOREWORD
1) The In te rn a tio n al E le ctro tech n ica l C om m ission (IE C ) is a w o rld w id e o rg a n iza tio n fo r sta n da rd iza tio n com prising
all national e le ctro te ch n ica l co m m itte e s (IEC N ational C om m ittees). The o bject o f IEC is to prom ote
in te rn a tio n a l co -o p e ra tion on all q u e stion s concerning sta n da rd iza tio n in the e le ctrica l and e le ctro n ic fields. To
th is end and in add itio n to o th er a ctivitie s, IEC publishes In te rn a tio n al Standards, T echnical S pecifications,
T echnical R eports, P ublicly A va ila b le S p e cifica tio n s (PAS ) and Guides (h e re a fte r referred to as "IEC
P u b lica tio n (s)"). T he ir p reparation is entrusted to te ch nical com m ittees; any IEC N ational C om m ittee interested
in the su b je ct d e a lt w ith may pa rticip a te in th is preparatory w ork. In te rn a tio n al, governm ental and non
governm ental o rg a n iza tio n s lia isin g w ith the IEC also pa rticip a te in th is p reparation. IEC co lla b o ra te s closely
w ith the In te rn a tio n al O rganization fo r S ta ndardization (ISO ) in accordance w ith co n d itio ns determ ined by
agreem ent between the two o rg a n iza tio n s.
2) The form al de cisio n s or agreem ents o f IEC on te ch nical m atters express, as nearly as possible, an in ternational
consensus o f o p in io n on the releva n t subjects since each te ch nical com m ittee has repre se n ta tio n from all
interested IEC N ational C om m ittees.
3) IEC P u b lica tio n s have the form o f recom m endations for in te rn a tio n a l use and are accepted by IEC N ational
C om m ittees in th a t sense. W hile all reasonable e ffo rts are made to ensure th a t the te ch nical co n ten t o f IEC
P u b lica tio n s is a ccu ra te , IEC cannot be held resp o n sib le for the w ay in w hich they are used o r fo r any
m isin terp reta tio n by any end user.
4) In ord e r to prom ote in te rn a tio n a l uniform ity, IEC N ational C om m ittees undertake to apply IEC P ublications
tran sp a ren tly to the m axim um e xte nt possible in th e ir national and regional p u b lications. Any divergence
betw een any IEC P ublication and the co rresponding national or regional pub lica tio n shall be cle a rly indicated in
the latter.
5) IEC provides no m arking procedure to in d ica te its approval and cannot be rendered resp o n sib le fo r any
equipm ent declared to be in co n fo rm ity w ith an IEC P ublication.
6) A ll users should ensure that they have the la te st e d itio n o f this publication.
7) No lia b ility shall attach to IEC or its d irecto rs, em ployees, servants or agents in cluding in d ivid u a l experts and
m em bers o f its te ch nical com m ittees and IEC N ational C om m ittees fo r any personal injury, property dam age or
other dam age o f any nature w hatsoever, w hether d ire ct or in d irect, or for co sts (in clu ding legal fe e s) and
expenses arising out o f the pub lica tio n, use of, or relia nce upon, th is IEC P ublication o r any o th er IEC
P u blications.
8) A tte n tio n is draw n to the N orm ative references cited in th is pub lica tio n. Use o f the referenced p u b lica tio ns is
in d ispensable for the co rre ct a p p lica tio n o f th is publication.
9) A tte n tio n is drawn to the p o ssib ility th a t some o f the elem ents o f th is IEC P ublication m ay be the su b je ct of
patent rights. IEC shall not be held resp o n sib le for ide n tifyin g any or all such patent rights.
In te rn atio na l Standard IEC 62093 has been prepared by IEC te ch n ica l com m ittee 82: S olar
p h o to vo lta ic energy system s.
82/374/FD IS 82/380/R V D
Full inform ation on the vo ting fo r a pproval can be found in the rep ort on voting indicated in the
above table.
T his p ub lica tion has been drafted in accorda nce w ith the ISO /IEC D ire ctives, P art 2.
-8 - 62093 © C E I:2005
Le co m ity a d 6cid£ que le contenu de cette p ublication ne sera pas m odifte a v a n t la date de
m aintenance indiquâe sur le site w eb de la CEI sous «h ttp ://w e b s to re .ie c .c h » dans les
donnees relative s â la p ub lica tion recherchee. A ce tte date, la p ublication sera
• reconduite;
• supprim ee;
• rem placee par une e dition revisee, ou
am endee.
62093 © IE C :2005 - 9 -
The co m m itte e has decided th a t the co nte nts o f this p ub lica tion w ill rem ain unchanged until
the m ainten an ce resu lt date indicated on the IEC web site u nder "h ttp ://w e b s to re .ie c .c h M in
the data related to the sp e cific p ub lica tion . A t th is date, the p ub lica tion w ill be
reconfirm ed;
w ithdraw n;
replaced by a revised edition, or
• am ended.
-IQ- 62093 © C E I:2005
C O M P O S A N T S BOS DES S Y S T E M E S P H O T O V O L T A IQ U E S -
Q U A L IF IC A T IO N ET ESSAIS D ’E N V IR O N N E M E N T
1 D o m a in e d ’a p p lic a tio n e t o b je t
La presente N orm e in te r n a tio n a l sp ecifie les e xigences pour la q u a lifica tio n apres les e ssais
d ’e n viro n n e m e n t des co m p osa nts de system es photovoltaVques (PV) (BO S ) p ou r a pp lica tion
te rre stre a da pte s â un fo n ctio n n e m e n t de longue duree â I'in te rie u r, co n d itio n n e s ou non
co nd itionnes, ou â I’e xterieu r, â des clim a ts typ iqu es â l’a ir libre, p roteges ou non proteges,
com m e d efin i dans la CEI 60721-2-1. Elle e st destin ee aux co m p osa nts sp ecifiqu es au
solaire te ls que batterie s, onduleurs, c o n trö le u rs de charge, co nn ecte u rs, ense m b les de
diodes, ra d ia te urs, lim ite urs de tension, boîtes de jo n c tio n du system e, d is p o s itifs de suivi de
la puissance m axim ale, a p p a re illa g e , fils e t câbles, m ais peut etre a pp lica ble â d ’autres
elem ents co m p le m e n ta ire s du system e.
La p resente norm e est basee su r les ele m e n ts sp e cifie s dans la CEI 61215 et la CEI 61646
pour la q u a lifica tio n des m odules PV. C ependant, des m od ifica tio ns ont ete e ffe ctu e e s pour
prendre en com pte les ca ra cte ristiq u e s p a rtic u lie re s des ele m e n ts co m p le m en taires, et pour
a jo u te r d iffe re n ts niveaux de se verite pour les d iffe re n ts e ssais d ’enviro n ne m e nt. La
poussiâre, les m oisissures, les insectes, des v ib ra tio n s et des chocs au cours des tran spo rts
et une classe de p ro tectio n ont ete a joutes aux ca te g o rie s d ’e n viro n n e m e n t app ro priee s. Les
lim ites de te m p era ture et d ’hum idite âle vâe s et fa ib le s o n t â ga le m en t 6tâ m o d if ie s pour etre
rep re se n ta tive s des e nviro n ne m e nts appropriâs.
La p resente norm e ne s’appliq ue pas aux m odules photovoltaVques. C eux-ci sont tra ite s dans
la CEI 61215 ou dans la CEI 61646. De plus, la p resente norm e ne s 'a p p liq u e pas aux
m odules â co nce ntra tion ou aux system es PV com plets. La p resente norm e ne tra ite pas des
aspects sp ecifiqu es â la se cu rite e le ctriq u e.
La p resente norm e s ’applique aux a ccum ula teu rs e t aux b atte rie s au plom b et nickel-
cadm ium . D’a utres system es de stockage e le ctro ch im iq u e s se ro nt inclus lo rs q u ’ils seront
disp on ible s.
L ’o b je t de cette sequence d ’essais est de d ete rm in e r les ca ra c te ris tiq u e s des p erform ances
de chaque â lâm ent de com posant et de m ontrer, dans la m esure du possible e t dans des
co ntrain te s raison n ab le s de co dt et de tem ps, que le c o m p osa nt e st capable de m ainten ir
cette p erform an ce aprâs rea lisa tion des e ssais d ’e nviro n ne m e nt co rre sp o n d a n t aux se rvices
a uxquels il e st d estinâ, com m e sp £ c ifi£ par le fa brican t. L ’e spâ ra nce de vie r6e lle des
com posants ainsi q u a lifie s dâpendra de leu r co nce ptio n, de leu r e nviro n ne m e nt et des
co nd itio ns dans lesq ue lle s ils fo nctio nn e nt.
2 R e fe r e n c e s n o rm a tiv e s
Les d ocu m e nts de reference su iva nts so nt in d ispe nsa ble s pour I'ap plicatio n du present
docum ent. Pour les re fe ren ces datees, seule I'edition cite e s'a p pliqu e. P our les references
non d ate es, la d e rnie re edition du d ocu m e nt de refe ren ce s 'a p pliqu e (y co m p ris les e ventuels
am endem ents).
CEI 60068-1, E ssais d 'e n viro n n e m e n t - P rem iere p a rtie : G e ne ra lites e t guide
CEI 6 0068-2-21, E ssais d 'e n viro n n e m e n t - P artie 2-21: E ssais - E ssa i U: R ob ustesse des
so rtie s et des d isp o s itifs de m ontage in c o rp o râ s
62093 © IE C :2005 - 11 -
B A L A N C E -O F -S Y S T E M C O M P O N E N T S
FOR P H O T O V O L T A IC S Y S T E M S -
DESIGN Q U A L IFIC A TIO N N A TU R A L E N V IR O N M E N T S
This In te rn atio na l Standard e sta b lish e s req uirem en ts fo r the d esign q u a lific a tio n o f balance-
of-system (BO S) co m p on en ts used in te rre stria l p h o to vo lta ic (P V ) system s. T his standard is
suitab le fo r ope ra tion in indoor, co nd itio ne d or unco nd itio n ed ; o r o u td o o r in g eneral o p e n-air
clim a tes as d efined in IEC 607 21 -2 -1 , protected or unp ro te cted . It is w ritten fo r dedicated
so la r co m ponents such as batterie s, inve rters, charge c o n tro lle rs, system diode packages,
heat sinks, surge p rotectors, system ju n c tio n boxes, m axim um pow er p oint trackin g devices
and sw itch gear, but m ay be app lica ble to o th e r BOS system com ponents.
T his standard is based on th a t w hich is specified in IEC 61215 and IEC 61646 fo r the design
q u a lifica tio n o f PV m odules. H ow ever, changes have been m ade to a cco u n t fo r the special
fe atures o f the b alan ce-o f-system com ponents, and to add d iffe re n t levels o f se ve rity fo r the
d iffe re n t se rvice enviro n m e nts. Dust, fu ng us, insects, shipping vibratio n and shock, and
p ro tectio n class have been added to the a pp ro priate e nviro n m e nta l c a teg ories. The high and
low te m p era ture and h um id ity lim its have also been m odified fo r the a pp ro priate se rvice
e nvironm ents.
This standard does not apply to p h o to vo lta ic m odules. These are covered by IEC 61215 or
IEC 61646. A lso, th is standard does not a pp ly to c o n ce n tra to r m odules o r to com p le te PV
system s. S p ecific e le ctrica l sa fe ty a spe cts are not part o f th is standard.
T his standard is app lica ble to lea d-a cid and nickel-cadm ium ce lls and batterie s. O ther
e le ctroch em ical sto ra ge system s w ill be included w hen they becom e a vailable.
The o b je ct o f th is te st sequence is to dete rm ine the perform ance c h a ra c te ris tic s o f each BOS
co m ponents and to show , as fa r as possible w ithin reason ab le co n s tra in ts o f cost and tim e,
th a t the co m p on en t is capable o f m aintain in g this perform ance a fte r expo sure to the sim ulated
se rvice natural e nviro n m e nta l co nd itio ns fo r w hich it is intended to be a pp lica ble as specified
by the m an ufa ctu re r. The actua l life e xpe ctan cy o f co m ponents so q ua lifie d w ill depend on
th e ir design, th e ir e n viro n m e nt and the system co nd itio ns u nder w hich th ey are operated.
2 Normative references
The fo llo w in g referenced docum ents are indispe nsa ble fo r the a p p lica tio n o f th is docum ent.
For dated references, only the e dition cited applies. For undated references, the latest edition
o f the referenced docu m e nt (in clud ing any a m endm ents) applies.
CEI 6 0068-2-27, E ssais d 'e n viro n n e m e n t - DeuxiĞme P a rtie: E ssais - E ssa i Ea e t g uide :
C hocs
CEI 6 0068-2-30, E ssais d 'e n viro n n e m e n t - D euxiem e P a rtie : Essais. E ssa i Db e t g u id e : E ssa i
cycliqu e de c h a le u r hum ide (cycle de 12 + 12 heures)
CEI 6 0068-2-78 , E ssais d 'e n viro n n e m e n t - P artie 2 -7 8: E ssais - E s s a i C ab: C h a le u r hum ide,
e ssa i continu
CEI 60410, P lans e t reg ie s d 'e ch a n tillo n n a g e p o u r les co ntröle s p a r a ttrib uts
CEI 60721-2-1, C la ssifica tio n des c o n d itio n s d ’e n v iro n n e m e n t - P artie 2-1: C onditions
d ’e n viro n n e m e n t p râ se n te s dans la n atu re - T em perature et hum iditâ
CEI 6 0904-3:1989, D isp o sitifs pho tovo lta i'qu es - Troisiem e p a rtie : P rin cip e s de m esure des
d isp o sitifs so la ire s pho tovo lta i'qu es (PV) â usage te rre stre in c lu a n t les donnees de
l'â c la ire m e n t sp e ctra l de râfârence
CEI 61215, M odules p hotovoltai'ques (PV) au s iliciu m c ris ta llin p o u r a p p lica tio n te rre s tre -
Q u alificatio n de la co n ce p tio n e t h om olo ga tion
CEI 61345, E ssa i a ux rayons u ltra vio le ts des m od ule s pho tovo lta i'qu es (PV)
CEI 61646, M od ule s pho tovo lta i'qu es (PV) en co uch es m in ces p o u r a p p lic a tio n te rre s tre -
Q u alificatio n de la co nce ptio n et h om ologation
CEI 61683, S ystem es pho tovo lta i'qu es - C on ditio nn eu rs de p u issa n ce - P ro ced ure de m esure
du re n d e m e n t
CEI 62262, D egres de p ro te ctio n p ro c u re s p a r les e nveloppes de m ate rie ls e le c triq u e s contre
le s im p a cts m eca niq ue s e xterne s (code IK)
3 Echantillonnage
Pour les e ssais de q u a lifica tio n , au m oins tro is e ch a n tillo n s d ’un c o m p osa nt (plus les pieces
de rechange n ece ssaires) d oiven t etre pre le ve s au hasard dans un ou p lusieurs lots de
pro du ction , co n fo rm e m e n t â la procedure donnee dans la CEI 60410. Les com posants doivent
a vo ir ete co n stru its â p a rtir de m ate ria ux et de co m p osa nts sp ecifies, co nfo rm e m e nt aux
dessins e t fich es d ’instru ction a pp ro pries e t d o ive n t a vo ir ete soum is au co n trö le norm al, au
contröle de la q ua lite et aux procedures d 'a cce p ta tio n de la production du fa b rica n t. Les
com posants d o ive n t etre co m plets ju s q u e dans les m oindres d eta ils et d oiven t etre
accom pagnes des instru ction s relative s â la m an ip u la tion , au m ontage et â la connexion
fo u rn ie s par le fa b rica n t, y com pris la tension m axim ale a dm issib le du system e.
Dans le cas d ’â lâm ents, par exem ple fils e t câbles, qui ne fo n t pas l’o b je t de m esures dâfin ie s
auparavant, une q u a n tity su ffisa n te pour les essais d oit etre prâlevâe au hasard dans un ou
p lu sieu rs lots de p roduction, co nfo rm e m e nt â la procedure donnâe dans la CEI 60410.
62093 © IE C :2005 -1 3 -
IEC 600 68 -2 -2 7 , E n viro n m e n ta l te sting - P art 2: Tests. Test Ea and g uida nce : Shock
IEC 600 68 -2 -3 0 , E n viro n m e n ta l te stin g - P a rt 2: Tests. T est Db a nd g u id a n ce : D am p heat,
cyclic (12 + 12-hour cycle)
IEC 600 68 -2 -7 5 , E n viro n m e n ta l te sting - P art 2 -7 5: Tests - Test Eh: H am m er tests
IEC 6 0068-2-78, E n viro n m e n ta l te s tin g - P art 2-78: Tests - Test Cab: D am p heat, steady
state
IEC 600 68 -3 -6 , E n viro n m e n ta l te sting - P art 3-6: S upp o rtin g d ocu m e ntatio n a nd g uida nce -
C on firm a tion o f the p erfo rm a n ce o f te m p e ra tu re / h u m id ity cham bers
IEC 60721-2-1, C lassification o f enviro n m e nta l conditions - P art 2-1: E nviro nm e nta l conditions
a pp ea rin g in n atu re - T em perature a nd h u m id ity
IEC 61215, C rysta llin e silico n te rre s tria l p h o to v o lta ic (PV) m od ule s - D esign q u a lific a tio n and
type a p p ro va l
IEC 61646, Thin film silico n te rre s tria l p h o to v o lta ic (PV) m od ule s - D esign q u a lific a tio n and
type a p p ro va l
3 Sampling
For q u a lifica tio n testing a q u a n tity o f a t least three sam ples o f a co m p on en t (plus spares as
desired) shall be taken at random from a p ro du ction batch or batches, in accorda nce w ith the
procedure given in IEC 60410. The co m ponents shall have been m anufactured from specified
m ate ria ls and co m ponents in accorda nce w ith the re le va n t d raw ings and process sheets and
shall have been su bjected to the m a n u fa ctu re r’s norm al in sp e ctio n , q u a lity control and
production a ccep tan ce p rocedures. The co m ponents shall be com plete in every detail and
shall be accom panied by the m an ufa ctu re r's handling, m ounting and co nn ectio n instru ction s,
including the m axim um p erm issible system voltage.
In the case o f item s, fo r exam ple w ire s and cables, th a t do not have p re vio u sly defined
m easures, a su ffic ie n t am o un t fo r the testing purposes shall be taken a t random from a
production batch o r batches, in a ccorda nce w ith the procedure given in IEC 60410.
-1 4 - 62093 © C E I:2005
4 Marquage
C haque co m p osa nt d oit p o rte r les m arquages su iva nts clairs et ind ele biles:
La date (et si possible I'he ure) et I’e n d ro it de la fa b rica tio n d o ive n t etre m arques sur le
co m p osa nt ou etre retro uve s â p artir du num ero de serie ou de lot.
NOTE Les p etits com posants tels que les fils, les connecteurs, les fusibles, etc. n’ont pas besoin de porter ces
m arquages elabores. Les in fo rm a tio n s m inim ales sont le nom /m onogram m e/sym bole du fa b rica n t ou du fo u rn isse u r
et le type ou num öro de m odule.
5 Documentation
5.1 Generalites
La docu m e ntatio n d oit co n te n ir les inform a tion s su iva n te s (le cas echeant):
- co n fo rm ite â des norm es a p p lica b le s (cela est p a rtic u lie re m e n t im p o rta n t en ce qui
conce rn e les D ire ctives e uropeennes et le m arquage CE apparente);
- instru ction s d ’insta lla tio n et de d econnexion;
- instru ction s de fo nctio nn e m e nt;
- u tilisa tio n en se rvice du co m p osa nt (voir 6.1);
- donnâes te chn iqu es (schem a de c irc u it et sp e c ific a tio n s techniques);
- instru ction s de depannage;
- a ve rtisse m e n ts et in stru ctio n s de securite;
- inform a tion s sur les pieces detachees;
- g arantie;
- in stru ctio n s relative s â la m ise hors se rvice et a I’evacu atio n.
4 Marking
Each co m p on en t shall ca rry the fo llo w in g cle a r and ind elible m arkings:
The date (and p re fera bly tim e) and place o f m an ufa ctu re shall be m arked on the com ponent
o r be tra ce a b le from the serial o r batch num ber.
NOTE Sm all com ponents such as w ires, connectors, fuses, etc. need not have these elaborate m arkings. The
m inim um inform ation is nam e/m onogram /sym bol o f m anufacturer or su p p lie r and the type o r m odel num ber.
5 Documentation
5.1 G e n e ra l
The docu m e ntatio n shall contain the fo llo w in g inform a tion (if relevant):
- co m p lia nce w ith releva n t sta nd ard s (this is e s p e c ia lly im p o rta n t w ith resp ect to European
D ire ctives and the related CE m arking);
- in sta lla tio n and d isco nn ectio n instru ction s;
- o pe ra ting instru ction s;
- se rvice use o f the co m p on en t (see 6.1);
- te ch n ica l data (c irc u it diagram and te chn ical s p e cifica tio n s);
- tro u b le sh o o tin g instru ction s;
- sa fety w arnin gs and instru ction s;
- inform a tion on spare parts;
- w arranty;
- in stru ctio n s fo r deco m m issio nin g and disposal.
6) Bornes de connexion
7) C ables (entree, so ulag em e nt de tra ctio n , se ction s)
8) Pieces d etachees
c) P roprietes e le ctriq u e s du com posant
1) Pour les co ntröle urs de charge
- In dication des types de b atte rie s inco m p a tibles et c o m p atib les
- T ension nom inale de I’entree et de la sortie (V)
- C ou ra n t m axim al de charge m odule (A)
- C ou ra n t m axim al de charge (A)
- Type de co n trö le u r (co n trö le u r en serie, co n trö le u r en parallele , etc.)
- P rincipe de fo n ctio n n e m e n t (PW M , reg ula tion en deux points, a lg orith m e de I’etat
de charge, etc.)
- Toutes les te nsio ns de seuil utilise es (V)
- C om pensation de te m p era ture pour les seuils (m V /°C /ele m e nt)
- C ou ra n t de repos
- C ourbe ind iqu an t la p uissa n ce /le co uran t d ’e ntree et de sortie par rap po rt â la
te m p e ra tu re am biante
- P u issance abso rb ee â m esurer au cours du fo n ctio n n e m e n t im m e diatem en t apres
la deco nn exio n de decharge im portante
- P u issance absorbâe au cours du fo n ctio n n e m e n t â la tension nom inale
- P ro tectio n co ntre les su rch arge s
- P rotection co ntre les inve rsio ns de polarite
- D efin ition de la zone de tension a uto rise e su r le cote entree et su r le cote sortie
- A ve rtisse m e n t avant d econnexion de la charge
- D efin ition du co m p orte m e nt de sortie en cas d ’absence de connexion â la batterie
- D econnexion d ifferee de (’u tilisa tion
- A ffich a g e s (affich ag e LED, prâcision des m esures)
- F onctions su pp lâ m en taires (suivi MPP, etc.)
- V a ria tio n m axim ale en co uran t a lte rn a tif du co uran t de charge de la b atterie
NOTE Si la borne negative de la ba tterie , le m odule et la charge ne peuvent pas âtre relies, il fa u t que cela soit
cla ire m e n t etabli et que le com portem ent dans un tel cas so it d efini.
2) For batterie s
- T ype o f b attery: NiCd, lead-acid, vented (flooded), v a lve -re g u la te d , g a s -tig h t sealed
(N iC d only), tu b u la r plate, fla t plate, etc.
- N om inal voltage
- S p ecific g ra vity o f the e le ctrolyte
T ou te s les donnees d oiven t etre ve rifiee s au cours des se qu en ces d 'e ssa is su iva ntes. Les
donnees, qui sont m anquantes ou ne so nt pas conform es aux in d ica tio n s du fa b rica n t, d oiven t
etre e n re g istre e s co nscien cieu sem e nt.
62093 © IE C :2005 -1 9 -
All data shall be ve rified in the course o f the fo llo w in g te s t sequences. D ata, w hich are
m issing o r do not conform to the in d ica tio n s o f the m an ufa ctu re r, shall be c o n scie n tio u sly
recorded.
- 20- 62093 © C E I:2005
6 Essais
La se verite des essais est basee sur I’u tilisa tio n reelle en se rvice (â in d iq u e r par le fa b rica n t)
du co m p osa nt. C elle-ci est d efinie de la façon suivante.
Les co nd itio ns d ’essai pour ces d iffe re n ts se rvices so nt resum ees au T ableau 1.
Les co m p osa nts d oiven t etre d ivise s en tro is g roupes et soum is aux se qu en ces d ’e ssais de
q u a lifica tio n du T ableau 1, râa lisâ es s u iva n t I’ordre s p e cific. C haque encadrâ fa it reference
au p aragraphe co rre sp o n d a n t de la prâsente norm e. Les p ro ced ures et les s6v6rit6s d ’essai,
y co m p ris les m esures in itia le s e t fin ales, si n ^c e s s a ire , sont d âta ill6 e s â l’A rtic le 11 et
r6sum 6es au T ableau 1. T ro is g roupes de co m p osa nts d o ive n t to u t d ’abord etre soum is â des
essais d ’e nviro n ne m e nt de base, â la suite d esquels un essai cycliqu e de c h aleu r hum ide
(voir 11.15) d oit etre râalisâ. A prâs chaque essai d ’e nviro n ne m e nt de base, un exam en visuel
(VI), un essai de fo n ctio n n e m e n t (FT) et un essai d ’isole m e nt (IT) d oiven t etre râa lisâ s. Tous
les g ro u p e s/p iâ ce s d o ive n t etre soum is â leur essai de fo n ctio n n e m e n t individ ue l avant et
apres chaque essai de q ua lifica tio n .
Le T ableau 1 co m p orte un resum e des nive au x d 'e ssa i. Pour les a p p a re ils e le ctron iqu es, tous
les essais s ’a pp liq ue nt. Pour les batteries, ce rta in s e ssais ne s ’a p p liq u e n t pas, et on peut
e galem ent tro u ve r un resum e au T ableau 1.
NOTE 1 Lorsque les m esures finales pour un essai se rve n t de m esures in itia le s pour le prochain essai de la
sequence, il n 'est pas necessaire de les repeter. Dans ces cas, les m esures in itia le s sont ignorees dans I'essai.
NOTE 2 Dans le cas o l i le com posant en essai a d6ja et6 soum is â un certain essai dans une autre sequence de
q u a lifica tio n par un la b o ra to ire d 'essa i a ccre d ite , cet essai peut etre ig nore s’il n'a pas d 'in flu e n ce sur I’in te g ra lite
de la sequence d’essais.
En râalisant les essais, l’opârateur d’essai doit observer rigoureusement les instructions re la tiv e s â la
m an ip u la tion , au m ontage et â la connexion fo u rn ie s par le fa brican t. Le rap po rt d ’essai doit
â ta b lir la base de toute om ission d ’essai.
62093 © IE C :2005 -2 1 -
6 Testing
The te st se ve ritie s are based on the se rvice use (to be indicated by the m a n ufa ctu re r) o f the
com ponent. T hese are defined as follow s.
a) O utdoor, u nprotected
The co m p on en t is fu lly exposed to d ire c t rain, sun, w ind, dust, fu ng us, ice, rad ia tio n to the
cold n ig ht sky, etc.
b) O utdoor, protected
The co m p on en t is p a rtia lly covered to p ro te ct it from d irect rain, sun, w ind -b low n dust, ice,
fu ng us, and rad ia tio n to the cold n ig ht sky, etc.
c) Indoor, unconditioned
The co m p on en t is fu lly covered by a building or e nclosu re to p ro tect it from d ire c t rain,
sun, w ind-blow n dust, fungus, and radiation to the cold night sky, etc, but the building or
e nclo su re is not co nd itio ne d in term s o f te m p era ture , h um id ity o r a ir filtra tio n .
d) Indoor, co nditioned
The co m p on en t is fu lly covered by a building o r e nclosu re to fu lly p ro tect it from rain, sun,
w ind -b low n dust, fungus, and rad ia tio n to the cold n ig ht sky, etc, and the building or
e nclosu re is g e n e ra lly co nd itio ne d in term s o f te m p era ture , h um id ity and a ir filtra tio n .
The co m ponents shall be d ivided into th re e groups and su bjected to the q u a lific a tio n test
sequences in Table 1, carried out in the o rd e r laid dow n. Each box refers to the corresp on din g
subclause in this standard. T est procedures and se veritie s, including in itia l and final
m easurem ents w here necessary, are detailed in C lause 11 and sum m arised in Table 1. Three
gro up s o f co m p on en ts shall firs t be su bjected to basic e nviro n m e nta l te sting , a fte r w hich a
dam p heat, cyclic te st (see 11.15) shall be done. A fte r each basic e nviro n m e nta l test, a visual
insp ectio n (VI), a fu n ctio n in g te st (FT ) and an insu latio n te st (IT ) shall be done. All
g ro u p s/p ie ce s shall be subjected to th e ir individ ua l fu n ctio n in g te st before and a fte r each
q u a lifica tio n test.
T able 1 co nta ins a sum m ary o f te s t levels. For e le c tro n ic e qu ip m en t all tests apply. For
b atte rie s certa in tests do not apply, a sum m ary can also be found in Table 1.
NOTE 1 W here the final m easurem ents for one test serve as the in itia l m easurem ents for the next te st in the
sequence, they need not be repeated. In these cases, the in itia l m easurem ents are om itted from the te st.
NOTE 2 In the case where the com ponent under test has a lrea d y been su bjected to a certain te st in ano th e r
q u a lifica tio n sequence by an a ccredited te st lab. th is test may be om itted if it does not have an in flu e n ce on the
whole testing sequence.
In carrying out the tests, the te s te r shall s tric tly o bserve the m an ufa ctu re r's handling,
m ounting and conn ectio n instru ction s. The te st rep ort shall state the basis fo r any test
om ission.
- 22- 62093 © C E I:2005
11.1 Exam en visuel V o ir la liste d e taille e pour exam en en 11.1.2 Oui Oui
11.2 Essai de fo n ctionnem ent Tem p6rature am biante: 25 °C; 40 ± 20 % Oui Oui
HR
11.4 Essai d 'iso le m e n t 500/1 000 V en courant continu + deux fois Non Oui
la tension en circu it o u ve rt du systâm e ou
1 m in. R esistance d 'iso le m e n t de 50 M£2 au
m inim um â 500 V en courant continu
11.8 Essai de vib ra tio n s au cours des 10 Hz â 11,8 Hz; 11,9 Hz â 150 Hz Oui Oui
transports
A m p litu d e : 3,5 mm, acce le ra tio n : 2 g
O ther
Secondary
Test Title T est conditions electron ic
batteries
equipm ent
11.1 V isual inspection See detailed inspection list in 11.1.2 Yes Yes
11.8 S hipping vib ra tio n test 10 Hz to 11,8 Hz; 11,9 Hz to 150 Hz Yes Yes
A m plitude: 3,5 mm, a cceleration: 2 g
1 octave/m in, D uration on each axis: 2 h;
o ve ra ll: 6 h
Table au 1 (suite)
11.14 Essai de robustesse des sorties Com m e dans la CEI 60068-2-21 Oui Oui
Table 1 (continued)
3 pieces
7 Criteres d’acceptation
La conce ptio n du co m p osa nt d o it etre ju g e e com m e s a tis fa is a n t aux essais de q u a lific a tio n de
la conce ptio n si chaque e cha ntillon d ’essai rem plit tous les c rite re s suivants:
a) le co m p osa nt su b it a vec succes ses essais de p erform an ce sp ecifiques;
b) aprâs I’essai final de chaque sequence d ’e ssais, le co m p osa nt su b it avec succâs I’essai
de fo nctio nn e m e nt;
c) aucun â ch a n tillo n n ’a p râsentâ de d efa ut irre v e rs ib le de c irc u it o uve rt ou d ’isole m e nt au
cours des e ssais: sont a uto risâ e s les s itu a tio n s ind uite s par le co m p osa nt lui-m em e afin
de se p ro tâg e r lui-m em e ou to u t autre d is p o s itif ou charge c o n n e cts (et il peut done etre
re in itia lis e norm alem ent);
62093 © IE C :2005 - 27-
3 pieces
7 Pass criteria
The co m p on en t design shall be jud ge d to have passed the design q u a lific a tio n tests if each
te st sam ple m eets all the fo llo w in g criteria:
d) il n'y a pas de d âfa ut visuel m ajeu r Evident, com m e ceux d âfin is â l'A rticle 8;
e) le com posant su b it a vec succes l'e s s a i d 'isole m e nt.
De nom breux co n trö le u rs de charge u tilis e n t la tension de la b atterie com m e param etre
princip al pour I'alg orithm e de co m m utatio n. C ependant, ce rta in s co ntröle urs de charge
u tilise n t d ’a utres param etres, par exem ple I'etat de charge. L'A n ne xe A co ntie nt des te nsio ns
d ’interru ptio n recom m andâes pour les batterie s au plom b.
Le fa b rica n t d oit sp e cifie r cla ire m e n t au lab o ra to ire d ’essai I’a lg orith m e de fo n ctio n n e m e n t du
co n trö le u r de charge. Si la te nsio n de la b atterie est u tilise e com m e param etre princip al pour
I’a lg o rith m e de com m utation, le fa b ric a n t d oit s p e c ifie r ces seuils.
7.2.2 T en sio n de sortie d ’un c o n trö le u r de charg e apres deco n nexio n de la batterie
Le co n trö le u r de charge d oit p ro teg e r la charge de la tension en c irc u it o uve rt du reseau PV,
au cas oli la b atterie a ete deco nn ectee du system e. II s ’a git d ’une c a ra cte ristiq u e im portante
des bons co ntröle urs de charge, e ta n t donne que des com posants p euvent etre d etruits
lo rsq u ’ils sont exposes â la tension en c irc u it o uve rt du reseau PV.
C erta in s co n trö le u rs de charge â usage sp ecial, par exem ple les co ntröle urs d edies pour
a p p lica tio n s in d u strie lle s, ne co n tie n n e n t pas d ’in fo rm a tio n s u tilisa te u r. Le fa b ric a n t d oit
p re cise r ce point.
If any co m p on en t does not m eet these te s t c rite ria , nor the sp ecific criteria fo r the com ponent,
the design shall be deem ed not to have m et the q u a lific a tio n req uirem en ts, and a n o th e r two
co m ponents m eeting the req uirem en ts o f C lause 3 shall be su bjected to the w hole o f the
releva n t te st sequence from the beginning. If one or both o f these also fa il, the design shall be
deem ed not to have m et the q u a lific a tio n req uirem en ts. If, how ever, both co m ponents pass
the te st sequence, the design shall be jud ge d to have m et the q u a lific a tio n requirem ents.
M any charge co n tro lle rs use the b attery voltage as the m ain p aram eter fo r the sw itching
alg orith m . H ow ever, som e charge c o n tro lle rs use o th e r param eters, fo r exam ple state o f
charge. A nnex A co nta ins som e recom m ended sw itchin g vo ltag es fo r lea d-a cid batteries.
The m an ufa ctu re r shall cle a rly sp ecify to the te s t lab the ope ra ting alg orith m o f the charge
co ntrolle r. If the b a tte ry voltage is used as the m ain param eter fo r the sw itchin g alg orith m , the
m an ufa ctu re r shall sp e cify these th re sho lds.
The charge co n tro lle r shall p ro tect the load from the o p e n -c irc u it voltage o f the P V -array, in
case the b attery has been d isco nn ected from the system . T his is an im p o rta n t fe ature o f good
charge co ntrolle rs, since m any loads can be d estroyed w hen th ey are exposed to the open-
circu it voltage o f the PV -array.
The m an ufa ctu re r shall su pp ly a d e fin itio n o f the o utp ut b eh aviou r in the case o f no b attery
connection.
C ertain special purpose charge co n tro lle rs, fo r exam ple d edicated c o n tro lle rs fo r ind ustry
a p p lica tio n s do not have a user feedback. The m an ufa ctu re r shall state this.
L ead-acid and nickel-cadm ium b atte rie s can o n ly be q ua lifie d according to th is standard fo r
the co nd itio ns ‘ind oo r co n d itio n e d ’ and ‘ind oo r u n c o n d itio n e d ’. T his im plies th a t m any tests
are not relevant. T able 1 co nta ins an o vervie w o f the te sts th a t apply to the design
q u a lifica tio n fo r se con da ry batteries.
- 30- 62093 © C E I:2005
7.3.1 C o n servatio n de la charge des b atteries d ’accu m u lateu rs â des tem p eratu res
elevees
7.3.1.1 O bjet
7.3.1.2 P rocedure
- C o n d itio n n e r la batterie
- R ea lise r un essai de ca pa cite in itia l, d ete rm in e r C 10 avant
- M ainten ir la b atterie â 40 °C pendant 30 jo u rs
- R ea lise r un nouvel essai de ca pa cite, d e te rm in e r C 10 apr6s
- C a lcu le r la perte de charge: Cperte = C10 apr4s _ C 10 avant
7.3.1.3 E xigences
La perte de ch arge ne d o it pas etre su pe rie ure â 15 % pour les batterie s au plom b et â 30 %
pour les b atte rie s nickel-cadm ium .
7.3.2.1 O bjet
L 'o b je t de cet essai est de d ete rm in e r la ca pacite des b atte rie s â re siste r aux cond itio ns
typ iqu es de cycles se p ro d u isa n t dans les system es PV.
7.3.2.2 P rocedure
7.3.2.3 E xigences
La m ethode d ’essai d ecrite dans la CEI 61427 d oit etre realise 1 fois. La perte com paree â la
ca pacite a ssignee (C 10) d oit etre inferie u re â 20 %.
7.3.3.1 O bjet
L ’o b je t de cet essai est de d ete rm in e r le ren de m e nt de cycle Ah des b atte rie s d ’a ccu
m ulateu rs â fa ib le etat de charge.
Le ren de m e nt d ’une b atterie â fa ib le e ta t de charge d oit etre s u ffis a n t pour p erm e ttre â toute
I’e nergie fo urnie par les m odules PV d ’etre co nve rtie en e nergie u tilisa b le stockee dans la
batterie.
62093 © IE C :2005 -3 1 -
7.3.1 C harge reten tion of seco n d ary b atteries at high tem p e ratu re s
7.3.1.1 Purpose
The purpose o f th is te st is to dete rm ine the charge retention o f b atte rie s during sto ra ge at
h ig he r te m peratures.
7.3.1.2 P rocedure
- C ondition the battery
- Do an initia l ca p a city test, dete rm ine C 10 bef0re
- Keep the b attery at 40 °C fo r 30 days
- Do a new ca p a city test, dete rm ine C 10 after
- C alcu la te the loss in charge: C,oss = C 10 after - C10 before
The loss in charge shall not be m ore than 1 5 % fo r lea d-a cid batterie s and not m ore than
30 % fo r nickel-cadm ium batteries.
7.3.2.1 Purpose
The purpose o f this te st is to d ete rm ine the c a p a b ility o f the b attery to w ithstan d the typical
cycling co n d itio n s o ccurrin g in PV system s.
7.3.2.2 P rocedure
The te st m ethod d escrib e d in IEC 61427 shall be perform ed once. The loss com pared to the
rated ca p a city (C 10) shall be less than 20 %.
7.3.3.1 Purpose
The purpose o f th is te st is to d ete rm ine the A h -cyclin g e ffic ie n c y o f se con da ry b atte rie s at low
state o f charge.
The e fficie n cy o f a b attery at low state o f ch arge shall be su ffic ie n t to ena ble all energy
provided by the PV m odules to be converted into usable ene rg y stored in the battery.
- 32- 62093 © C E I:2005
7.3.3.2 Procedure
C ycle initia l:
C ycles:
Pour ca lcu le r la va le u r du ren de m e nt de cycle Ah, les va le urs du 4 6me cycle et du 5®me cycle
sont m oyennees.
(C ette plage a ete choisie car les va le urs de ren de m e nt co rresp on da n tes so nt plus sta ble s.)
62093 © IE C :2005 - 33 -
7.3.3.2 Procedure
In itial cycle :
C ycling:
soc %
Potential V
100%
50%
1,8 Vpc
10 h 2h 5h 2h 5h 2h 5h
To ca lcu la te the A h -cyclin g e fficie n cy va lu e the values o f the 4 thcycle and the 5th cycle are
averaged.
(This range has been se lected because the corresp on din g e ffic ie n c y values are m ostly
stable.)
- 34- 62093 © C E I:2005
7.3.3.3 E xigences
Pour les batterie s au plom b â plaque plane, le rendem ent de cycle Ah (â 20 °C) d o it etre d ’au
m oins 94 %.
Pour les batterie s au plom b â plaque tu bu laire, le ren de m e nt de cycle Ah (â 20 °C ) d oit etre
d ’au m oins 92 %.
Pour les b atte rie s nicke l-ca dm ium , le rendem ent de cycle Ah (â 20 °C ) d o it etre d ’au m oins
90 %.
8 D e fa u ts v is u e ls m a je u rs
Pour les besoins de la q u a lifica tio n de co nce ptio n, chacun des d âfa uts su iva nts est considârâ
com m e un d âfa ut visuel m ajeur:
9 R a p p o rt
Pour la q u a lifica tio n de la co nce ptio n, un rap po rt des e ssais de q u a lifica tio n , in clu a n t les
resu lta ts de m esure des ca ra cte ristiq u e s de perform ance ainsi que le detail de chaque d efa ut
et essai de rep rise ou les om ission s d o it etre prepare par le lab ora toire d ’essai. Le rapport
doit sa tisfa ire aux exig en ces sp ecifiee s dans la ISO /C EI 17025 . Une co pie de ce rap po rt d oit
etre co nse rve e par le fa b rica n t pour etre utilise e en ta n t que reference.
10 M o d ific a tio n s
T oute m od ifica tio n dans la co nce ptio n, les m atâriaux, les com posants ou les tra ite m e n ts du
com posant peut n â ce ssite r une rep etitio n de ce rta in s ou de I’e nsem ble des e ssais de
q ua lifica tio n .
11 P r o c e d u r e s d 'e s s a i
11.1.1 O bjet
11.1.2 P rocedure
E xam iner avec soin chaque co m p osa nt pour les co nd itio ns suivantes:
For fla t-p la te lead-acid batterie s, the A h -cyclin g e ffic ie n c y (at 20 °C ) shall be at least 94 %.
For tu b u la r plate lea d-a cid batteries, the A h -cyclin g e ffic ie n c y (at 20 °C ) shall be at least
92 %.
For the purposes o f design q u a lific a tio n , the fo llo w in g are co nside red to be m ajor visual
d efects:
9 Report
F ollow ing d esign q u a lifica tio n , a rep ort o f the q u a lifica tio n te sts, w ith m easured perform ance
ch a ra cte ristics and d eta ils o f any fa ilu re s, re-te sts o r om ission s shall be prepared by the test
la b ora tory. The re p o rt shall m eet the requirem ents laid dow n in ISO /IEC 17025. A copy o f this
rep ort shall be kept by the m an ufa ctu re r fo r refe ren ce purposes.
10 Modifications
11 Test procedures
11.1.1 Purpose
11.1.2 P rocedure
- co rrosio n visible des co nn exion s de so rtie , des in te rco n n e xio n s et des barres om nibus;
- co rrosio n visible de la surface de I’enveloppe;
- fil ou câble fe le ou endom m age;
- bornes d e fe ctu eu ses, p arties e le ctriq u e s sous te nsio n exposees;
- toute a utre co nd itio n qui peut a ffe c te r le fo n ctio n n e m e n t, les p erform an ces ou la securite.
Un releve et/ou une pho tog rap hie d oiven t etre fa its de la nature et de (’e m p la ce m e nt de tous
les d efa uts qui p euvent s ’a gg ra ver et a ffe c te r d e fa v o ra b le m e n t le fo n ctio n n e m e n t du
co m p osa nt lors des essais qui suivent.
11.1.3 E xigences
Des criteres d 'a sp e ct a utres que les d efauts visue ls m ajeurs d e c rits â I'A rticle 8 sont
possible s dans le but de la q u a lifica tio n de la co nce ptio n.
La pro ced ure com prend les co n trö le u rs de charge pour a ccum ula teu rs au plom b avec un
e le ctro lyte liquide (ouverts et â reg ula tion par soupape).
Les e ssais d e crits dans cette procedure sont va la ble s pour les c o n trö le u rs de charge qui
u tilise n t la tension aux bornes de l’a ccu m u la te u r com m e critâre de fo nctio nn e m e nt, ainsi que
des procedures de co n trö le m odernes (par exem ple a lg orith m e s de l’â ta t de charge). Dans le
cas ou I’ensem ble ou ce rta ins de ces essais ne sont pas p ertine nts pour un type sp âcifiqu e
de co n trö le u r de charge, le fa b rica n t d oit I'etablir.
Les sym boles su iva nts so nt u tilise s dans le pre sen t docum ent:
Umax: tension m axim ale du system e > tension la plus elevee de la b atterie auto rise e par
le co n trö le u r de charge (p a r exem ple te nsio n de b ou illon n em en t)
11.2.1.2.1 O bjet
L ’o b je t de cet essai est de d ete rm in e r tous les seuils de com m utation du co n trö le u r de
charge.
62093 © IE C :2005 - 37-
- visib le corrosio n o f o utp ut co nn ectio ns, inte rco n n e ctio n s and bus bars;
- visib le corrosio n o f the e nclosu re surface;
- cracked or dam aged w ire o r cable;
- fa u lty te rm ina ls, exposed e nergised e le c tric a l parts;
- any o th e r co n d itio n s w hich m ay a ffe c t fu n ctio n in g , perform ance o r safety.
M ake note o f a nd /or photograph the nature and position o f any defects w hich m ay w orsen and
a dve rse ly affe ct the co m p on en t fu n ctio n in g in su bse qu en t tests.
V isual co nd itio ns o th e r than the m ajor visual defe cts listed in C lause 8 are a ccep tab le fo r the
purpose o f design q ua lifica tio n .
11.2.1 F u nctio n in g test procedu re - charge c o n tro lle rs for lead -acid batteries
11.2.1.1 O verview
This pro ced ure co m p rise s charge co n tro lle rs fo r lead-acid a ccum ula tors w ith liquid e le ctrolyte
(vented and valve regulated).
The tests d escrib e d in th is pro ced ure are valid fo r charge c o n tro lle rs, w hich use the
a ccum ula tor te rm ina l vo ltag e as a criterion fo r ope ra tion as w ell as m odern co ntrol procedures
(e.g. state o f charge a lg o rith m s). In the case w he re all o r som e o f these tests are not releva n t
fo r a sp e cific type o f charge co n tro lle r, the m an ufa ctu re r shall state this.
Umax: m axim um system voltage > h ighest b a tte ry voltage perm itted by charge
co n tro lle r (for exam ple, gassing voltage)
11.2.1.2.1 Purpose
1 1.2.1.2.2 A p pa re illa g e
Une resista nce {R x) a vec une a m p litu d e Umm/ { lchmax x et une puissance absorbee
auto risâ e d ’au m oins l / max x /chmax x 1,1. C ette resista nce est destin de â em p ech er le
co uran t de passe r dans I’a lim e n ta tio n E lectrique. Dans le cas le plus d âfa vo ra b le (courant
m axim al du m odule lorsque la charge est coupâe), l’a lim en ta tion E lectrique fo urnira to ujo urs
un co u ra n t de 0,1 x /Chmax- Si une alim en ta tion e le ctriq u e â quatre q ua dran ts e st utilisee,
cette resista nce n ’est pas necessaire.
Une source de co ura n t/te n sio n qui peut a lim e n te r au m oins /chmax â la te nsio n en circu it
o uve rt ( Uoc) du g en e ra te u r PV co nn ecte (a lim e n ta tio n e le ctriq u e 1). Le co uran t et la tension
d oiven t pouvoir etre fixes ind ep en d am m e nt I’un de I’a utre et so nt lim ites.
Une a utre source de co ura n t/te n sio n qui peut a lim e n te r au m oins un co uran t avec une
a m plitude {U max/R x) + /lmax â la te nsio n m axim ale du system e (alim e ntatio n e le ctriq u e 2).
Le co uran t et la tension d oiven t p ou voir etre fixe s ind ep en d am m e nt I’un de I’a utre et sont
lim ites. Si une a lim e n ta tio n e le ctriq u e â quatre q ua dran ts est utilise e, un co uran t possible
m axim al de /)max est s u ffisa n t â la tension m axim ale du system e. Dans ce cas, la resistance
d ecrite ci-d e ssu s (Rx) n’est plus necessaire.
Une resista nce va riab le [R L) avec une puissan ce absorbee d ’au m oins Umax x /!max ou une
charge e le ctron iqu e co rrespondante.
Un o scillosco pe pour v isu a lise r la m odulation de large u r d ’im pulsion lorsque les te nsio ns de
fin de charge sont atte in te s.
1 1.2.1.2.3 P rocedure
Les com posants du system e d oiven t etre e xam ines co nce rn an t les dom m ages visibles.
T ou te s les p a r tic u la r ity o bse rve es d o ive n t etre d ocu m e ntee s co nscien cieu sem e nt, si
nece ssaire, au m oyen de p ho tographies.
1 1.2.1.2.2 A pparatus
A re sisto r (R x) w ith a m agnitude Umin/{ lchmax x 1,1) and an allow ed pow er consu m p tion o f at
least l / max x /chmax x 1,1. This re sis to r is intended to keep the cu rre n t from being fed into the
pow er supply. In the w orst case (m axim um m odule cu rre n t when load is sw itched off), the
pow er supply w ill still su pp ly a cu rre n t o f 0,1 x /chmax. If a fo u r-q u a d ra n t pow er supply is
utilise d, th is re sisto r is not necessary.
A c u rre n t/vo lta g e source th a t can supply at least /chmax at o p e n -c irc u it voltage (Uoc) o f the
P V -g en e ra to r connected (pow er supply 1). C urren t and voltage shall be capable o f being set
se p a ra te ly from each o th e r and have lim ita tion s.
A n o th e r c u rre n t/vo lta g e source w hich can su pp ly at least a cu rre n t w ith a m agnitude
(^ m a x ^ x ) + ^imax at m axim um system vo ltag e (po w e r supply 2). C urren t and voltage shall be
capable o f being set se p a ra te ly from each o th e r and have lim ita tio n s. If a fo u r-q u a d ra n t pow er
supply is utilise d, a m axim um possible cu rre n t o f /)max is su ffic ie n t at m axim um system
voltage. In th is case, the re sisto r described above (R x) is no lon ge r necessary.
A va ria b le re sisto r (R L) w ith a pow er co nsum ption o f at le a st Umax x /,max o r a corresp on din g
e le ctro n ic load.
An o scillosco pe fo r visua lisin g the pulse w idth m odulation w hen e nd -o f-cha rg e vo ltag es are
reached.
1 1.2.1.2.3 P rocedure
A ny p e cu lia ritie s obse rve d shall be co n s c ie n tio u s ly d ocum ented, if nece ssary by m eans o f
photography.
The ch arge co n tro lle r is m ounted according to the m an ufa ctu re r's instru ction s and hooked up
as show n in Figure 3. If there are any voltage se nso r lines on the charge co ntrolle r, they shall
be co nn ecte d to pow er supply 2. Betw een pow er supply 1 and the charge c o n tro lle r a
m inim um o f 10 m o f the prescribed cable shall be installed to sim u late a real system . Betw een
pow er supply 2 and the ch arge co n tro lle r a m inim um o f 2 m o f the prescribed cable shall be
installed.
- 40- 62093 © C E I:2005
Les exam ens su iva nts so nt rea lise s â une te m p era ture am b ia n te d ’environ 20° C, â co ndition
que rien d ’autre ne so it indiquâ pour les e ssais appropri6s.
1) F ixer une tension de system e de 1,1 x l / Nomina| â I’a lim en ta tion e le ctriq u e 2.
2) F ixer R L, de te lle sorte q u ’un co uran t de charge de 0,5 x /,max s o it etabli.
3) F ixer un co uran t de m odule de /Chmax ^ I’a lim e n ta tio n e le ctriq u e 1 (co n d itio n s de charge).
F ixer la lim ite de te nsio n sur la te nsio n en c irc u it o u v e rt du g e n e ra te u r PV â connecter.
NOTE Dans le cas d ’un co n trö le u r parallöle, v e ille r â ne pas endom m ager I’alim e nta tio n 6 le ctriq u e ou le
c o n trö le u r de charge en raison d un courant excessif.
4) A u gm e nte r la tension â I’a lim en ta tion e le c triq u e 2 par paliers de 0,2 V. A tten dre environ
30 s entre les paliers sâparâs et o b se rve r le systâm e.
5) R epeter l’etape 4 ju s q u ’a o b te n ir les ele m e n ts su iva nts, en fo n ctio n du type de co ntröle ur:
C on trö le u r en serie:
a vec un co ntröle en deux points: c irc u it o uve rt â I’a lim e n ta tio n e le ctriq u e 1, lim ite de
tension active
a vec une PW M: d ebut des im p ulsio ns de tension (pa sser de la
te nsio n du system e â la lim ite de tension â
I’a lim en ta tion e le ctriq u e 1) â l’entree PV du c o n trö
leu r de charge (o scillo sco pe ).
62093 © IE C :2005 -4 1 -
NOTE 1 Depending on the charge c o n tro lle r under te st, a ca p a citor o f at le a st 50 fiF m ust be connected p a rallel
to the output te rm inals o f the pow er supply 2.
NOTE 2 It is stron g ly advised to discuss the actual te st set-up w ith the m anufacturer. T his te st set-up is suitable
for m any charge co n tro lle rs on the m arket. However, depending on certain fa cto rs, including pow er supply type,
certain charge co n tro lle rs w ill need a m odified set-up o r sp e cific preparation.
The fo llo w in g e xam in a tion s are perform ed at an a m b ie n t te m p era ture o f a pp ro xim a tely 20 °C,
as long as nothing else is indicated fo r the a pp ro priate tests.
4) Increase the vo ltag e at pow er supply 2 in steps o f 0,2 V. W a it a pp ro xim a tely 30 s betw een
the se pa ra te steps and o bserve the system .
5) R epeat step 4 until the fo llo w in g becom es the case, d epending on the typ e o f co ntrolle r:
S erial co n tro lle r
w ith tw o -p o in t co ntrol: o p e n -c irc u it at pow er supply 1, vo ltag e lim ita tion active
w ith PW M: s ta rt o f voltage pulses (change betw een system voltage and
voltage lim ita tio n a t pow er supply 1) a t PV inp ut o f charge
co n tro lle r (o scillo sco pe ).
- 42- 62093 © C E I:2005
C o n trö le u r en parallâle:
a vec un co ntröle en deux points: co u rt-c irc u it â l’a lim en ta tion e le ctriq u e 1, lim ite u r de
co uran t a c tif
a vec une PW M: d eb ut des im p ulsio ns de tension (pa sser de la
tension du system e â 0 V) â l'e n tre e PV du
co n trö le u r de ch arge (oscillo sco pe ).
6) N oter le reglage de tension â l’a lim en ta tion e le ctriq u e 2.
7) Si le co n trö le u r a une PW M: rep ete r l’etape 4, m ais par paliers de 50 mV, ju s q u ’a ce que
la tension â l’entree PV reste co nsta nte â ze ro (c o n trö le u r en p a ra lle le ) ou s o it lim itee par
I’a lim en ta tion e le ctriq u e (co n trö le u r en se rie). N oter le reglage de tension â l’a lim en ta tion
e le ctriq u e 2.
11.2 .1 .2.3.2 D eterm in atio n de la ten sio n d ’e g a lis atio n des charges (si presente)
8) F ixer un co uran t de m odule de 0,2 x /Chmax a l'a lim e n ta tio n e le c triq u e 1 (con ditio ns de
decharge).
9) R eduire la tension â l’a lim en ta tion e le ctriq u e 2 par paliers de 0,2 V. A tten dre environ 30 s
e ntre les paliers et o b se rve r le system e.
NOTE Ce tem ps de m aintien peut âtre trop co u rt pour ce rta in s types de co n trö le u rs de charge. Se r6f6rer
aux in d ica tio n s des fabricants.
10) R epeter l'etape 9 ju sq u 'a ce que la tension soit in fe rie u re â ce lle indiquee par le fa b rica n t
com m e e tan t nece ssaire pour a c tiv e r la fo n ctio n de b ouillonnem ent.
11) R epeter les etapes 3 â 7. S 'il y a p lu sie u rs te nsio ns de b ou illon n em en t avec les niveaux
de d ecle n ch e m e n t a pp ro pries, repeter les etap es 3 â 11 en consequence.
11.2 .1 .2.3.3 D eterm in atio n des ten s io n s de deco n nexio n et de reco n n exio n â charge
faib le
12) R ep eter l’etape 8. R epeter l’etape 9 ju s q u ’a ce que l’alarm e de rejet de charge du
co n trö le u r (si pre sen te ) soit declenchee. N oter le reglage de tension.
13) R epeter l’etape 9 ju s q u ’au re je t de charge. N oter le reglage de tension.
14) R ep eter l’etape 3. R epeter l’etape 4 ju s q u ’a reconnexion de la charge. N oter le reglage
de tension.
15) F ixer la te nsio n â l’alim en ta tion e le ctriq u e 2 sur 1,1 x UNomjna|.
16) R âpâter les âtap es 12 â 15 a vec des co uran ts de charge fix£ s de 0 %, 25 %, 75 % et
100 % de /lmax.
NO TE C et essai peut d onner des resu lta ts errones dans le cas de ce rta in s co n trö le u rs avances, u tilisa n t des
se u ils d ependant du courant ou des se u ils dependant de l'e ta t de charge.
11.2.1.3 E xigences
Les se u ils de co m m utation d oiven t etre co nsta nts (c ’e st-â -d ire de l’ordre de 2 %) avant et
apres chaque essai.
11.2.2.1 P rocedure
- C o n d itio n n e r la b atterie en râa lisa n t une pro ced ure de ch arge initia le selon les instru ction s
du fa brican t. C ela sera g e n e ra le m e n t â / 10.
- D eterm in er la ca pacitâ C10 de la b atterie en d âch a rg e a n t â /10.
- Afin de co n se rve r la b atterie, rech arge r la b atterie â /10 ju s q u ’a ce que 1,2 fo is de la
ca pacite a ssignâe C 10 a it âtâ chargâe dans la batterie.
62093 © IE C :2005 - 43-
P a rallel co ntrolle r
w ith tw o -p o in t co ntrol: sh ort circu it at pow er su pp ly 1, c u rre n t lim ita tio n active
w ith PW M: sta rt o f voltage pulses (change betw een system vo ltag e and
0 V) at PV inp ut o f charge c o n tro lle r (o scillo sco pe ).
6) Note dow n vo ltag e setting at pow er su pp ly 2.
7) If co n tro lle r has PW M: repeat step 4, but in steps o f 50 mV, until the vo ltag e at PV input
stays co n sta n t a t ze ro (shunt co n tro lle r) o r is lim ited by the pow er su pp ly (serial
co n tro lle r). Note dow n vo ltag e setting at pow er su pp ly 2.
11.2 .1 .2.3.2 D eterm in ing the charg e equ alisin g v oltag e (if present)
8) Set a m odule cu rre n t o f 0,2 x /chmax at pow er su pp ly 1 (discha rge co n d itio n s).
9) R educe the vo ltag e at pow er supply 2 in steps o f 0,2 V. W a it a p p ro xim a te ly 30 s
betw een steps and o bserve the system .
NOTE T his dw ell tim e m ay be too sh o rt for certain types o f charge co n tro lle rs. Please refe r to the
m anufacturers indication.
10) R epeat step 9 until the vo ltag e is below th a t indicated by the m an ufa ctu re r as being
nece ssary to a ctiva te the gassing fu n ctio n .
11) R epeat steps 3 to 7. If there are several gassing vo ltag es w ith the a pp ro priate trigg ering
levels, repeat steps 3 to 11 accordin gly.
11.2 .1 .2.3.3 D eterm in atio n of low charge d is co n n ec t and reco n n ect voltag es
12) R epeat step 8. R epeat step 9 until load rejectio n alarm o f c o n tro lle r (if p resent) is
trigg ered . Note dow n vo ltag e setting.
13) R epeat ste p 9 until load rejectio n . Note dow n vo ltag e setting.
14) R epeat ste p 3. R epeat step 4 until load reco nn ectio n. Note dow n vo ltag e setting.
15) Set vo ltag e at pow er supply 2 to 1,1 x ^Nominal-
16) R epeat steps 12 to 15 w ith set load cu rren ts o f 0 %, 25 %, 75 % and 100 % o f /|max.
NOTE T his te st can give erroneous results in the case o f certain advanced co n tro lle rs, using current d ependent
th re sh o ld s or thresholds depending on SOC.
The sw itchin g th re sh o ld s shall be co n sta n t (i.e. w ithin 2 %) before and a fte r each test.
11.2.2.1 P rocedure
- C ondition the b a tte ry by p erform ing an initia l charging pro ced ure as per the m an ufa ctu re rs
in stru ctio n . This w ill u sua lly be at / 10
- D eterm ine the C 10 b attery ca p a city by d isch arg in g at / 10.
- To conse rve the battery, recharge the b attery at / 10 until 1,2 tim es the rated C10 ca pa city
has been charged into the battery.
- 44- 62093 © C E I:2005
11.2.2.2 E xigences
La ca pa cite in itia le m esuree d oit etre d ’au m oins 95 % de la ca pacite nom inale.
La perte de charge a van t et aprâs chaque essai d ’e nviro n ne m e nt d oit etre inferie u re â 20 %,
en se r£fe ra n t â la ca p a city m esurâe initiale.
11.2.3.1 P rocedure
Faire fo n ctio n n e r I’o nd u le u r dans une co n fig u ra tio n râseau nom inale e t dans des cond itio ns
de so rtie nom inale. A p râs 30 m inutes de fo n c tio n n e m e n t â la puissance de sortie assignee,
m esurer le ren de m e nt de puissance co n fo rm e m e n t â la CEI 61683, le fa c te u r de puissance et
le ren de m e nt au point de puissance m axim ale (M P PT) pour les nive au x de puissance: 10 %,
25 %, 50 %, 75 %, 100 % et 120 % de la puissan ce de so rtie assignee sp e cifie e par le
fa brican t. Si I’o nd u le u r ne peut pas fo n c tio n n e r â 120 % de la puissan ce de sortie a ssignee, le
niveau de puissan ce m axim al possible d oit etre utilise.
11.2.3.2 E xigences
G e ne ra lem en t (sa u f ind icatio n co n tra ire ), il n ’est nece ssaire de re a lise r ces e ssais q u ’une
seule fois, et I’essai de fo n ctio n n e m e n t g en eral d ecrit en 11.2 sera repete apres chaque essai
d ’e nvironnem ent.
11.3.1 Proced ures d ’essai de perfo rm an ce s p ecifiq u es - con tro leurs de charg e pour
les batteries au plom b
11.3.1.1.1 O bjet
L ’o b je t de cet essai e st de
- d e te rm in e r to us les deca la ge s non desires des seuils de te nsio n en raison des va riatio n s
de tem perature,
- v e rifie r la co m pensation de te m p era ture provoquee par la te m p era ture de la batterie.
1 1.3.1.1.2 A p pa re illa g e
V o ir 11.2.1.2.2.
En plus, une cham bre clim a tiq u e capable de m ainten ir les niveaux de te m p era ture entre
- 1 0 °C e t 55 °C.
Toute cham bre d ’essai clim atique capable de satisfaire aux specifications de la CEI 60068-3-6
sera appropriee.
62093 © IE C :2005 - 45-
The in itia l m easured ca p a city shall be at least 95 % o f the nom inal capacity.
The loss o f charge before and a fte r each e nviro n m e nta l te st shall be less than 20 %, referring
to the in itia l m easured capacity.
11.2.3.1 P rocedure
O perate the in ve rte r u nder nom inal a rray co n fig u ra tio n and nom inal o utp ut co nd itio ns. A fte r
30 m in o f ope ra tion at rated o u tp u t pow er, m easure the p ow er e ffic ie n c y according to
IEC 61683, pow er fa cto r and m axim um pow er p oint trackin g (M P PT) e fficie n cy fo r the pow er
levels: 10 %, 25 %, 50 %, 75 %, 100 % and 120 % o f the rated o utp ut pow er specified by the
m anufacturer. If the in ve rte r ca nn ot ope ra te a t 120 % o f the rated o u tp u t pow er, the m axim um
pow er level possible shall be used.
The overall b eh aviou r o f p ow er e fficie n cy, pow er fa c to r and M PPT e fficie n cy shall not d iffe r
from the initia l b e h a vio u r at s ta rt o f the design q ua lifica tio n .
G e nerally, (unless stated o the rw ise ) these tests only need to be carried out once, w hereby
the g en eral fu nctio nin g te st described in 11.2 w ill be repeated a fte r every e nviro n m e nta l test.
11.3.1.1.1 Purpose
The purpose o f th is te st is to
- dete rm ine any unw anted sh ifts o f the vo ltag e th re sh o ld s due to te m p era ture va riatio n s,
- to ve rify te m p era ture co m pensation caused by the b attery tem perature.
1 1.3.1.1.2 A pparatus
See 11.2.1.2.2.
A d d itio n a lly, a clim a tic cham ber capable o f m aintain in g te m p era ture levels from - 1 0 °C up to
55 °C.
Every clim a tic te st cham ber, w hich is capable o f fu lfillin g the s p e c ific a tio n s o f IEC 6 0068-3-6
w ill be su itab le .
-4 6 - 62093 © C E I:2005
1 1.3.1.1.3 E xigences
Les se u ils pour la deco nn exio n de la charge d oiven t etre stables sur I’ensem ble de la plage
de te m peratures.
Par co ntraste avec les se u ils de la d6co nn exio n de charge, ceux de la p rotection co ntre les
su rch arge s e t les fo n ctio n s de b ou illon n em en t n ece ssiten t une co m p en satio n de tem perature
afin d ’a da pte r le co m p orte m e nt de charge de la b atterie a la te m p era ture enviro n na nte .
Les se u ils de p rotection de dech arge im p orta nte d o ive n t etre m aintenus sta ble s â
±20 m V /elem ent et les seuils de p rotection contre les su rch arge s d o ive n t pre sen te r des
co e fficie n ts de te m p era ture de - 3 m V /K /ele m e nt â - 5 m V /K /elem ent.
Les seuils de tension so nt â ta b lis avec les te m p era ture s su iva ntes, co n fo rm ^m e n t â 11.2.1.2.
Si le co n trö le u r de charge a une sonde de te m p era ture e xterne, seule cette sonde est
exposee aux te m p era ture s ci-d essu s, tandis que le co n trö le u r de charge lui-m em e fo nctio nn e
dans des co nd itio ns a m biantes. Si le co n trö le u r de charge n ’a pas de sonde de te m p âra ture
externe, l’e nsem ble du co n trö le u r de charge est expose aux te m p era ture s d 'e ssa i ci-dessus.
11.3.1.2.1 O bjet
1 1.3.1.2.2 E xigences
La chute de tension au niveau des bornes du co n trö le u r de charge entre les bornes de la
b atterie e t de la charge (de cha rg e) et entre les bornes du g en e ra te u r PV et de la batterie
(cha rg e) p euvent chacune ne s’e le ve r q u ’a un m axim um de 0,5 V (system e s de 12 V ) ou 1 V
(system es de 24 V) â une charge m axim ale ou â un co uran t de charge m axim al.
La chute de tension sur les lignes de b atterie peut e n tra în e r des valeurs de co ntröle erronees.
Le co n trö le u r de charge d oit done etre equ ip e d'(au m oins) une des p re cau tion s suivantes:
1 1.3.1.2.3 P rocedure
M esurer la chute de tension â la ch arge m axim ale ou le co uran t de charge m axim al au niveau
des bornes du co n trö le u r de ch arge e ntre les bornes de la b atterie et les bornes de la charge
(de cha rg e) et entre les bornes du g en e ra te u r PV e t les bornes de la b atterie (charge).
62093 © IE C :2005 - 47-
The th re sh o ld s fo r the load d isco n n e ct shall be stable across the entire range of
te m peratures.
In co n tra st to the th re sh o ld s o f the load d isco n n e ctio n , those o f the overcha rg e p rotection and
gassing fu n ctio n s req uire a te m p era ture co m pensation in o rd e r to a da pt the charging
b eh aviou r o f the b attery to the surrou nd ing tem perature.
The th re sh o ld s o f the d ee p -d isch a rg e p rotection shall rem ain sta ble w ithin ±20 m V /cell and
the th re sh o ld s o f the overload p rotection shall e xh ib it a te m p era ture c o e ffic ie n t o f
- 3 m V /K /cell to - 5 m V /K /cell.
The vo ltag e th re sh o ld s are ascertain ed u nder the fo llo w in g te m p era ture s in line w ith 11.2.1.2.
The charge co n tro lle r and te m p e ra tu re -se n so r shall be kept at each te m p era ture fo r a t least
15 min.
If the charge co n tro lle r has an e xternal te m p era ture sensor, only th is se nso r is exposed to the
above te m p era ture s, w hile the charge c o n tro lle r its e lf runs u nder a m b ie n t co nd itio ns. If the
charge co n tro lle r has no e xterna l te m p e ra tu re sensor, the entire charge c o n tro lle r is exposed
to the above te sting te m peratures.
11.3.1.2.1 Purpose
The purpose o f th is te st is to dete rm ine the voltage drop betw een the inp ut te rm ina ls o f the
charge co ntrolle r.
The voltage drop at the te rm in a ls o f the charge c o n tro lle r betw een b attery- and loa d-te rm ina ls
(d isch a rg in g ) and betw een P V -g en e ra to r- and b a tte ry -te rm in a ls (cha rg ing ) m ay each only
am ount to a m axim um o f 0,5 V (12 V system s) or 1 V (24 V system s) at m axim um load or
m axim um charging current.
The voltage drop on the b a tte ry-lin e s can lead to false co n tro l-va lu e s. H ence, the charge
co n tro lle r shall be equipped w ith (at lea st) one o f the fo llo w in g precautions:
1 1.3.1.2.3 P rocedure
M easure the voltage drop at m axim um load o r m axim um chargin g cu rre n t a t the te rm ina ls o f
the charge co n tro lle r betw een b attery- and lo a d -te rm in a ls (d isch a rg in g ) and betw een PV-
g e n e ra to r- and b a tte ry-te rm in a ls (charging).
-4 8 - 62093 © C E I:2005
11.3.1.3.1 O bjet
1 1.3.1.3.2 P rocedure
Une source de tension avec inversion de polarite est co nn ecte e aux bornes d ’entree du
m odule et la tension e st augm entee len te m e nt de 0 V â la tension en c irc u it o u v e rt m axim ale
adm issible du g en e ra te u r solaire. Au cours de cet essai, une source de tension avec une
p olarite co rrecte est co nn ecte e aux bornes de la b atterie du co n trö le u r de charge.
Une b atterie de ca pacite a daptee au co n trö le u r e st e nsuite co nn ecte e aux bornes d ’entree de
la b atterie avec une inversion de p olarite. Au cours de cet essai, une source de tension avec
une p olarite co rrecte est connectee aux bornes d ’entree du m odule du c o n trö le u r de charge.
Enfin, une source de tension avec inversion de p olarite est co nn ecte e aux bornes d ’entree du
m odule et la tension e st augm entee len te m e nt de 0 V â la tension en c irc u it o u v e rt m axim ale
a dm issib le du g ân â ra te u r so la ire . Au cours de cet essai, une b atterie a vec une ca pacite
adaptee au co n trö le u r a vec inversion de polarite est connectee aux bornes de la b atterie du
co n trö le u r de charge.
11.3.1.4.1 O bjet
1 1.3.1.4.2 E xigences
La p ro tectio n contre les su rch arge s d o it pouvoir re siste r â au m oins 125 % de la charge
m axim ale p ou r laquelle le co n trö le u r de charge est conçu. La p ro tectio n contre les su rch arge s
peut etre rea lise e avec un fu sible norm al ou a vec un c irc u it de p rotection ele ctron iqu e.
1 1.3.1.4.3 P rocedure
A la tension nom inale, la charge du co uran t est a ugm entee p ro g re ssive m e n t ju s q u ’a 125 %,
ou ju s q u ’a ce que la p rotection soit activee. Si le co n trö le u r de charge a une prise radio
separee, cela d oit alo rs aussi etre ve rifie pour la p ro tectio n contre les surcharges.
11.4.1 O bjet
L ’o b je t de cet essai est de d ete rm in e r si le c o m p osa nt est su ffisa m m e n t bien isole ou non
entre les p arties co nd uctrices e t I’enveloppe.
C et essai n’est pas nâce ssaire pour les batterie s. Faire atte ntio n que ce rta in s com posants
p eu ven t co n te n ir un a ppareil de p rotection se nsible qui sera d e tru it en e ta n t soum is a ces
essais. Se re fe re r au fa b rica n t en cas de doute.
L ’essai d o it etre realise sur les co m p osa nts â la te m p era ture am b ia n te de I’atm osphere
enviro n na nte (vo ir la CEI 6 0068-1) et â une hum idite relative ne d ep assa nt pas 75 %.
62093 © IE C :2005 - 49-
11.3.1.3.1 Purpose
To dete rm ine w h e th e r the charge c o n tro lle r fu n c tio n s sa fe ly w hen cu rre n t sources w ith
in co rre ct p o la rity are connected.
1 1.3.1.3.2 P rocedure
A source o f voltage with reverse p o la rity is connected to the m odule inp ut te rm in a ls and the
vo ltag e increased slow ly from 0 V to the m axim um p erm issible o p e n -c irc u it vo ltag e o f the
so la r gen erator. D uring th is test, a voltage source w ith c o rre c t p o la rity is connected to the
b attery te rm ina ls o f the charge co ntrolle r.
Then, a b attery w ith a ca pa city fo r w hich the c o n tro lle r is rated is connected to the battery
inp ut te rm ina ls w ith reve rse p olarity. D uring th is test, a voltage source w ith c o rre c t p o la rity is
connected to the m odule in p u t te rm in a ls o f the charge co ntrolle r.
Lastly, a source o f vo ltag e w ith reverse p o la rity is connected to the m odule inp ut term ina ls
and the vo ltag e slow ly increased from 0 V to the m axim um p erm issible o p e n -c irc u it voltage o f
the so la r gen erator. D uring th is test, a b attery w ith a ca pa city the c o n tro lle r is rated fo r with
reverse p o la rity is connected to the b attery te rm ina ls o f the charge co ntrolle r.
11.3.1.4.1 Purpose
To dete rm ine w he th er the overload p ro tectio n o f the charge c o n tro lle r fu n c tio n s properly.
The overlo a d p ro tectio n shall be able to w ithstan d at le a st 125 % o f the m axim um load fo r
w hich the charge co n tro lle r is d esigned. O verload p ro tectio n can be realised w ith a norm al
fu se o r w ith an e le ctro n ic p ro tectio n circu it.
1 1.3.1.4.3 P rocedure
A t nom inal voltage, the load o f the cu rre n t is increased step by step to 125 % o r until the
p ro tectio n s is a ctivate d. If the charge c o n tro lle r has a separate radio o utle t, then this shall
also be checked fo r p rotection from overload.
11.4.1 Purpose
To dete rm ine w h e th e r or not the com ponent is s u ffic ie n tly w e ll-in s u la te d betw een cu rren t-
carrying parts and the enclosure.
The te st shall be m ade on co m ponents at a m b ie n t te m p era ture o f the surrounding atm osphere
(see IEC 6 0068-1) and in a relative h um id ity not e xceeding 75 %.
- 50- 62093 © C E I:2005
11.4.3 P rocedure
- A ucune rupture d i^ le c triq u e (in fe rie ure â 50 fiA ) ou claq ua ge en surface au cours de
I’etape c) ne d oit se produire.
- La resista nce d ’isole m e nt ne d oit pas etre inferie u re â 50 M ft.
11.5.1 O bjet
L’o b je t de cet essai est de fa ire une Evaluation p r6 lim in a ire de I’a p titu d e d'un co m p osa nt â
su pp orte r une e xpo sitio n dans des co nd itio ns de site naturel et de râ vâ le r les effe ts d ’une
d egradation syn ergâ tiqu e qui ne p euvent pas etre d âte ctâ s par des essais e ffe ctu â s en
laboratoire.
NOTE II co nvient que to u t ju g e m e n t absolu sur la duree de vie d’un com posant a yant sa tisfa it â cet essai soit
considârâ avec prudence parce que l'essai est de courte durâe e t les co n d itio ns d 'en viro n n em e n t variables. II
co nvient de co n sid e re r cet essai seulem ent com m e un guide ou un in d ica te ur d 'eve n tu e ls problem es.
11.5.2 A p p a re illa g e
L ’a p p a re illa g e e st le suivant.
11.4.3 P rocedure
- No d ie le c tric breakdow n (less than 50 (iA ) or surface cracking during step c) shall occur.
- The insu latio n resista nce shall be not less than 50 MQ.
11.5.1 Purpose
NOTE C aution should be taken in m aking ab so lu te ju d g e m e n ts about com ponent life on the basis o f passing this
test because o f the shortness o f the test and the environm ental va ria b ility o f the test co n d itio ns. T his test should
only be used as a guide or in d ica to r o f possible problem s.
11.5.2 A pparatus
11.5.3 P rocedure
11.5.5 E xigences
- Pas d 'a p p a ritio n de d âfa uts visu e ls m ajeurs, com m e ceux d âfin is â l'A rticle 8.
- Les exig en ces de fo n ctio n n e m e n t de 11.2 d oiven t etre rem plies.
11.6.1 O bjet
Le degrâ de p rotection (code IK) d â fin it l’6 tendue â laquelle une enve lo pp e fo u rn it une
p ro tectio n contre les im pacts m ecaniques externes.
11.6.2 E xigences
Les e ssais so nt rea lise s co nfo rm e m e nt â la CEI 62262, en u tilis a n t le belier p endule d ecrit
dans la CEI 6 00 68 -2 -7 5 (essai Eha). L ’a pp areil est p re con ditio nn e p endant 1 h â - 1 0 °C dans
une cham bre; I’essai e st rea lise dans la m inute su iva nt son re tra it de la cham bre; il est
e ffectue dans des co nd itio ns a tm o sph e riqu e s de lab o ra to ire norm ales. Les m ethodes de cet
essai sont d e crite s â I’A n ne xe D de la CEI 62262. L ’a pp areil est m onte co nfo rm e m e nt â la
m ethode de p re pa ra tion 1.
L'e nve lo p pe ne doit pre sen te r aucune fe lure ou d istorsio n , qui p ou rra it etre n efaste â son
fo nctio nn e m e nt.
11.7 P ro tectio n contre la p o u ssiere, I’eau et les corps etran g ers (code IP)
11.7.1 O bjet
Le degre de p rotection (code IP) d e fin it l'e te nd ue â laquelle un b o îtie r fo u rn it une p rotection
contre l’acces â des parties d an ge re use s, la p en etra tion de corps e tra ng e rs so lid es et/ou
I’entree d ’eau e t de poussiere, com m e prouve par les m ethodes d ’essai norm alisees.
11.7.2 E xigences
Le code IP requis depend des co nd itio ns dans lesq ue lle s le co m p osa nt est utilise . S 'il est mis
en fo n ctio n n e m e n t dans des espaces interie u rs en dur, IP20 co nfo rm e m e nt â la CEI 60529
est adaptâ, a utrem e nt IP44 est requis.
62093 © IE C :2005 - 53-
11.5.3 P rocedure
11.6.1 Purpose
The degree o f p ro tectio n (IK -cod e) d efin es the e xten t to w hich an e nclosu re provides
p ro tectio n a ga in st e xternal m echanical im pact.
The tests are conducted in conform ance w ith IEC 62262 using the pendulum ham m er
described in standard IEC 6 00 68 -2 -7 5 (test Eha). The e quipm ent is p reconditioned fo r 1 h at
- 1 0 °C in a cham ber; the te st is perform ed w ithin 1 min o f its rem oval in norm al lab ora tory
a tm o sph e ric co nd itio ns. The m ethods o f th is te s t are described in A nnex D o f IEC 62262. The
e qu ip m en t is se t up according to p re pa ra tion m ethod 1.
The e nclosu re shall show no cracks o r d isto rtio n s, w hich could be d e trim e n ta l to its ope ra tion .
11.7.1 Purpose
The degree o f p ro tectio n (IP -cod e) d efin es the e xten t to w hich a case pro vid e s p rotection
a ga in st a ccess to d angerous parts, the pen etra tion o f solid fo re ign bodies a n d /o r the e n try of
w ater and dust, as proved by standard te sting m ethods.
The required IP -code depends on the co nd itio ns under w hich the co m p on en t is utilise d. If it is
operated in so lid ly b u ilt ind oo r spaces, IP20 in conform ance w ith IEC 60529 is adequate,
o th e rw ise IP44 is required.
- 54- 62093 © C E I:2005
Au cas ou des e nve lo pp e s so nt u tilise es, qui ont dejâ des ca ra c te ris tiq u e s IP c e rtifie e s
rem p lissa n t les exig en ces du pre sen t a rticle , il n’e st pas necessaire de re a lise r cet essai â
nouveau.
11.8.1 O bjet
L ’o b je t de ce t essai est d ’id e n tifie r les points de fa ib le sse m ecanique et/ou d ’e ta b lir toute
d e te rio ra tio n des p aram etres sp ecifies. C on fo rm em e nt â la CEI 600 68 -2 -6 , il d oit etre realise
sur des ele m e n ts ou des d isp o s itifs s tru ctu re ls, qui so nt exposes â des vib ra tio n s
h arm oniques au cours du tran sp o rt, te lle s que celles qui se p ro du isen t sur les navires, dans
les a vions e t les vehicule s te rre stre s.
11.8.2 E xigences
D egre de severite:
11.8.3 A p pareillag e
V o ir la CEI 60068-2-6.
11.8.4 P rocedure
V o ir la CEI 60068-2-6.
11.9.1 O bjet
C on jointem en t â I’essai p recedent, I’o b je t de cet essai est de d e co u vrir les points de fa iblesse
m ecanique et/ou de d e te rm in e r si les p aram etre s sp ecifies so nt ou non m aintenus ou
d âtâ rio râ s. Les essais sont râa lisâ s co nfo rm â m e nt â la CEI 60068-2-27.
62093 © IE C :2005 - 55-
In the case w here e nclosu res are used, w hich have a lre a d y a ce rtifie d IP -rating m eeting the
req uirem en ts o f this clause, this te st does not need to be done again.
11.8.1 Purpose
The purpose o f this te st is to id e n tify m echanical w eak points a nd /or to a scertain any
d e te rio ra tio n o f the sp ecified param eters. A cco rding to IEC 600 68 -2 -6 , it shall be conducted
on structural ele m e n ts or devices, w hich are exposed to harm o nic vib ra tio n s during shipm ent,
such as o ccur on ships, in a ircra ft and land vehicles.
11.8.3 A pparatus
11.8.4 P rocedure
The specim ens are n e ith e r packaged nor e nergised during the test.
11.9.1 Purpose
In co njun ction w ith the pre vio u s test, the purpose o f th is te st is to d is c o v e r m echanical w eak
points a n d /o r to d ete rm ine w h e th e r the specified p aram eters are m aintained o r d ete rio ra te .
The tests are conducted in conform ance w ith IEC 60068-2-27.
- 56- 62093 © C E I:2005
11.9.2 E xigences
Degre de severite:
11.9.3 A p p a re illa g e
V o ir la CEI 60068-2-27.
11.9.4 P rocedure
V o ir la CEI 60068-2-27.
11.10.1 O bjet
L ’o b je t de ce t essai est de d ete rm in e r I’a p titu d e du co m p osa nt â su pp orte r une e xpo sitio n aux
ra d ia tio n s u ltra vio le tte s (UV).
11.10.2 A p p a re illa g e
11.10.3 P rocedure
11.9.3 A pparatus
11.9.4 P rocedure
The specim ens are not packaged or live d urin g the test.
11.10 UV test
11.10.1 Purpose
The purpose o f th is te st is to d ete rm ine the a b ility o f the com ponent to w ithstan d expo sure to
u ltra -vio le t (UV) radiation.
11.10.2 A p paratus
11.10.3 P rocedure
a) Use the ca lib ra te d rad io m ete r to m easure the irra dian ce at the proposed co m p on en t test
plane and ensure that, at w ave le n g th s betw een 280 nm and 400 nm, the te st spectral
irradiance is never m ore than 5 tim es the corresp on din g standard sp ectral irra dian ce
sp ecified in the standard AM 1,5 so la r irra dian ce d istrib u tio n given by T able 1 o f
IEC 6 0904-3, th a t there is no a pp re cia b le irradiance at w ave len gth s below 280 nm and
th a t it has a u n ifo rm ity o f ±15 % over the te st plane.
- 58- 62093 © C E I:2005
b) F ixer le co m p osa nt dans le plan d ’essai â l’e m p la ce m e nt choisi en a) a vec le cöt6 le plus
critiq u e (par exem ple, le cötâ a vec le plus de p en etra tion s de fils ou de câbles)
p erpe n d icu la ire au fa iscea u d 'e cla ire m e n t UV.
c) T ou t en m ainten an t la te m p era ture du co m p osa nt dans la plage pre scrite , so um ettre le
co m p osa nt â un £ cla ire m e n t m inim al de:
- 7,5 k W h m -2 dans la plage de longueurs d ’ondes com p rise e ntre 280 nm et 320 nm, et
- 15 kW h-m -2 dans la plage de longueurs d ’ondes com p rise entre 320 nm et 400 nm.
d) R eo rie n te r le com posant, de telle sorte que la face a rrie re so it p erpe n d icu la ire au faisceau
d ’e cla ire m e nt UV.
e) R epeter I'etape c) pour 10 % du tem ps aux niveaux d ’e xpo sitio n energ etiq ue qui etaie nt
realises su r le co te avant.
11.10.5 E xigences
11.11.1 O bjet
L 'o b je t de cet essai est de d e te rm in e r I’a ptitu de du co m p osa nt â s u p p o rte r des co ntrain te s de
d e se q u ilib re th erm ique, de fa tigu e ou autres, causees par des va ria tio n s rep ete e s de
te m p era ture . Les lim ites de te m p era ture pour cet essai de cycles sont basees sur I’u tilisa tion
en se rvice de ce com posant: â I’e xte rie u r non protege, â I’e x te rie u r protege, â I’in te rie u r non
co nd itio nn e et â I’in te rie u r co nditionne.
11.11.2 A p p a re illa g e
a) Une cham bre clim a tiqu e avec un co ntröle de te m p era ture a uto m a tiq ue , des m oyens pour
fa ire circu le r l'a ir â l'in tâ rie u r et des m oyens pour â v ite r la co nd en satio n sur le co m p osa nt
au cours de I’essai, ca pa ble de so um ettre un ou p lu sieu rs co m p osa nts au cycle therm ique
reprâsente â la Figure 4. C haque cham bre c lim a tiq u e qui est capable de sa tisfa ire aux
s p e cifica tio n s de la CEI 600 68 -3 -6 sera a ppropriâe.
b) Des m oyens pour m onter ou s u p p o rte r le com posant dans la cham bre, de façon â
perm ettre une libre circu la tio n de I'air enviro n na nt.
c) Des m oyens pour m esurer et e n re g is tre r la te m p era ture du com posant a vec une precision
de ±2 °C. Les sondes de te m p era ture d o ive n t etre fixe es su r la face avant ou a rriere du
com posant, prâs du centre. Si plus d'un co m p osa nt e st e ssay6 sim u ltan â m e nt, il suffira
d 'e n re g istre r la te m p era ture d ’un seul exem plaire re p râ sen ta tif.
d) Des m oyens pour v e rifie r, pendant to u t I'essai, la c o n tin u ity du c irc u it interne de chaque
com posant.
e) De ('instrum entation pour v e rifie r, pour chaque com posant, I'in te grite de I'iso lem en t entre
l'une des bornes et le ch âssis du co m p osa nt ou la stru ctu re de support.
62093 © IE C :2005 - 59-
b) M ount the co m p on en t in the te st plane at the loca tion se lected in a) w ith the m ost critica l
side (fo r exam ple, the side w ith the m ost w ire o r cable p en etra tion s) norm al to the UV
irra dian ce beam.
c) W hile m aintaining the co m p on en t te m p era ture w ith in the prescribed range, su bject the
co m p on en t to a m inim um irra dian ce o f
- 7,5 k W h -rrr2 in the w ave len gth range betw een 280 nm and 320 nm, and
- 15 kW h-m -2 in the w ave len gth range betw een 320 nm and 400 nm.
d) R eo rie nt the co m p on en t so th a t the backside is norm al to the UV irradiance beam.
e) R epeat step c) fo r 10 % o f the tim e at the irra d ia tio n levels th a t w ere perform ed on the
fro n t side.
11.11.1 Purpose
11.11.2 A p paratus
a) A clim a tic cham ber w ith a u to m a tic te m p era ture co ntrol, m eans fo r c ircu la tin g the a ir inside
and m eans to avoid co nd en satio n on the co m p on en t during the test, ca pa ble o f subjecting
one o r m ore com ponents to the therm al cycle in Figure 4. E very c lim a tic cham ber w hich is
capable o f fu lfillin g the sp e cifica tio n s o f IEC 600 68 -3 -6 w ill be su itab le .
b) M eans fo r m ounting or supporting the com ponent in the cham ber, so as to allo w free
circu la tio n o f the surrounding air.
c) M eans fo r m easuring and recording the te m p era ture o f the co m p on en t to an accuracy o f
±2 °C. The te m p era ture sensors shall be attached to the fro n t or back surface o f the
com ponent near the m iddle. If m ore than one co m p on en t is tested sim u ltan e ou sly, it w ill
su ffice to m on itor the te m p era ture o f one rep re sen ta tive sam ple.
d) M eans fo r m onitoring, th ro u g h o u t the test, the c o n tin u ity o f the internal c irc u it o f each
com ponent.
e) In strum entation fo r m onitoring in each com ponent, the in te g rity o f the insu latio n betw een
one o f the te rm in a ls and the co m p on en t fram e or supporting structure.
-6 0 - 62093 © C E I:2005
Les lim ite s elevees et fa ibles requises pour les cycles de te m p era ture so nt fo u rn ie s au
T ableau 2.
T ableau 2 - Lim ites de tem p e ratu re pour I’essai de cycles therm iqu es
O
A I'exte rie u r, non protâgâ 50+200
CM
o
85 °C
I
A I'exte rie u r, protege 75 °C - 2 0 °C 50+200
IEC 514/05
11.11.4 P rocedure
a) In sta lle r le co m p osa nt â te m p era ture am biante dans la cham bre. Si I’enve lo pp e du
co m p osa nt est un m auvais co n d u cte u r e le ctriq u e , fix e r le co m p osa nt su r un châssis
m etallique.
b) C on ne cte r l’a pp areil de co ntröle de te m p era ture â la (ou aux) so nd e(s) de te m p era ture .
C onnecter ('instru m e ntatio n de co ntröle de la c o n tin u ity aux bornes du com posant.
C onnecter les m oyens de co ntröle de I'iso lem en t entre une borne et le ch âssis ou la
structure de support.
c) F erm er la cham bre et, I'air c irc u la n t a u to u r du ou des com posants â une vite sse d ’au
m oins 2 m s-1 , so um ettre le co m p osa nt â des cycles entre les lim ites de te m p era ture du
co m p osa nt sp e cifie e s au T ableau 2 selon le cycle d e c rit â la Figure 4. La vitesse de
variatio n de la te m p era ture e ntre les deux te m p era ture s extre m es ne d oit pas dep asse r
100 °C /h et la te m p era ture du co m p osa nt d oit etre m aintenue sta ble â chaque te m p era ture
extrem e pendant au m oins 10 m in. La d uree du cycle ne d oit pas d ep asse r 6 h. Le nom bre
de cycles d oit etre celui du panneau a pp ro prie de la Figure 1.
62093 © IE C :2005 -6 1 -
The required high and low lim its fo r te m p era ture cycling are provided in Table 2.
O
O utdoor, unprotected 50+200
CM
o
85 °C
I
O utdoor, protected 75 °C - 2 0 °C 50+200
IEC 514/05
11.11.4 P rocedure
a) Install the co m p on en t at room te m p era ture in the cham ber. If the co m p on en t enclosure is
a poor e le ctrica l conductor, m ount the com ponent on a m etal fram e.
b) C on ne ct the te m p era ture m onitoring e qu ip m en t to the te m p era ture se nso r(s). C onnect the
co n tin u ity instru m e ntatio n across the co m p on en t te rm ina ls. C on ne ct the insu latio n m onitor
betw een one term inal and the fram e or su pp o rtin g structure.
c) C lose the cham ber and, w ith the a ir around the co m p on en t(s) circu latin g at a ve lo c ity o f
not less than 2 m s-1 , su bject the co m p on en t to cycling betw een the com ponent
te m p era ture lim its specified in T able 2 in a ccorda nce w ith the p ro file in Figure 4. The rate
o f change o f te m p era ture betw een the low and high extre m es shall not exceed 100 °C/h
and the co m p on en t te m p era ture shall rem ain stable at each extrem e fo r a period o f at
least 10 m in. The cycle tim e shall not exceed 6 h. The n um ber o f cycles shall be as shown
in the relevant blocks in Figure 1.
-6 2 - 62093 © C E I:2005
11.11.6 E xigences
11.12.1 O bjet
Les lim ites de te m p era ture âlevâes et fa ib le s req uise s pour ce t essai sont fo urnie s au
T ableau 3.
A va n t d ’e ffe ctu e r I'essai, le co m p osa nt d o it etre soum is â I'essai de cycles therm iques,
com m e le m ontre la Figure 4.
62093 © IE C :2005 -6 3 -
d) T hro u g h o u t the test, record the co m p on en t te m p era ture and m on itor the c o m p on en t(s) to
d e te ct any o p e n -c irc u it o r ground fa u lts th a t m ay o c c u r during the exposure.
A fte r a m inim um reco very tim e o f 1 h, repeat te sts 11.1 and 11.2.
- T here sh all be no in te rm itte n t o p e n -c irc u it or ground fa u lts detected during the test.
- T here sh all be no e vidence o f m ajor visual d efects, as defined in C lause 8.
- The fu n ctio n in g requirem ents o f 11.2 shall be met.
11.12.1 Purpose
The purpose o f th is te st is to dete rm ine the a b ility o f the co m p on en t to w ithstan d the e ffects o f
high te m p era ture and h um id ity fo llow ed by a cold te m p era ture . T his is not a therm al shock
test.
The required high and low te m p era ture lim its fo r th is te s t are provided in T able 3.
O utdoor, unprotected 85 °C - 2 0 °C
O utdoor, protected 75 °C - 2 0 °C
Indoor, unconditioned
O
O
O
55 °C
Indoor, conditioned Not required Not required
B efore cond uctin g the test, the co m p on en t shall be su bjected to the th erm al cycling te s t as
show n in Figure 4.
-6 4 - 62093 © C E I:2005
11.12.3 A p p a re illa g e
L ’a pp areillag e et le suivant.
a) Une cham bre clim a tiqu e a vec co ntröle a uto m a tiq ue de la te m p era ture et de I'hum idite,
ca pa ble de so um ettre un ou p lusieurs com posants au cycle h um id ite -g el sp ecifie â la
Figure 5. C haque cham bre d ’essai clim a tiqu e, qui est capable de sa tis fa ire aux
sp e cifica tio n s de la CEI 600 68 -3 -6 sera a ppropriee. Pour les te m p era ture s au-de ssou s de
zero, le p oint de rosee de l'a ir â I'in te rie u r de la cham bre d oit etre egal â la te m p era ture de
la cham bre.
b) Des m oyens pour m esurer et e n re g is tre r la te m p era ture d'un co m p osa nt avec une
p re cisio n de ±2 °C. Si p lu sieu rs co m p osa nts so nt essayes sim u ltan e m e nt, il su ffit de
co n trö le r la te m p era ture d'un co m p osa nt re p re s e n ta tif du lot.
c) Des m oyens pour v e rifie r, p endant to u t I'essai, la c o n tin u ity du c irc u it interne de chaque
com posant.
d) De I'in strum e nta tion pour v e rifie r, pour chaque com posant, I'in te grite de I'iso lem en t entre
I'une des bornes et I'enveloppe ou la stru ctu re du ch âssis de support.
11.12.4 P rocedure
La procedure et la suivante.
a) P lacer une sonde de te m p era ture adequate sur la fa ce a van t ou a rriere du com posant,
pres du centre.
b) In sta lle r le co m p osa nt â te m p era ture am biante dans la cham bre clim a tiqu e avec un angle
d'au m oins 5° par rap po rt â I'ho rizo nta le. Si I’e nveloppe du com posant est un m auvais
co n d u cte u r e ie ctriq u e , fix e r le co m p osa nt sur un ch âssis m etallique.
c) C on ne cte r l’a ppareil de co ntröle de te m p era ture â la (ou aux) so nd e(s) de te m p era ture .
C on ne cte r I'in strum e nta tion de co ntröle de la c o n tin u ite aux bornes du com posant.
C on ne cte r les m oyens de co ntröle de I'iso lem en t entre une borne et le ch âssis ou
I’enve lo pp e du com posant.
62093 © IE C :2005 - 65-
11.12.3 A p paratus
11.12.4 P rocedure
A pres un tem ps de rep rise co m p ris e ntre 2 h et 4 h, re p e te r les essais 11.1 e t 11.2.
11.12.6 E xigences
11.13.1 O bjet
11.13.2 P rocedure
a) P re con dition n em en t
Le com posant, e ta n t â la te m p era ture am biante, d oit etre in tro d u it dans la cham bre
d ’essai.
b) S 6v6rit6s
Le niveau d ’hum iditâ d oit etre de 85 % ± 5 %, la durâe de I’essai de 1 000 h, et la
te m p âra ture du co m p osa nt de ±2 °C du niveau sp âcifiâ, co nfo rm e m e nt au T ableau 4:
T ab leau 4 - Lim ites de tem p e ratu re pour I’essai con tin u de ch aleu r hum ide
c) R eprise
Le co m p osa nt d oit etre soum is â une reprise d'une d uree com p rise e ntre 2 h et 4 h.
62093 © IE C :2005 - 67-
d) A fte r closing the cham ber, su bject the co m p on en t to ten com plete cycles in accordance
w ith Figure 5. The m axim um and m inim um te m p era ture s shall be w ith in ±5 °C o f the
specified levels and the relative h um id ity shall be m aintain ed w ithin ±5 % o f the specified
va lu e at all te m p era ture s above room tem perature.
e) T hro u g h o u t the test, record the co m p on en t te m p era ture and m on itor the co m p on en t to
d e te ct any o p e n -c irc u it o r ground fa u lts th a t m ay o c c u r during the exposure.
A fte r a reco very tim e o f betw een 2 h and 4 h, rep ea t tests 11.1 and 11.2.
- T here sh all be no in te rm itte n t o p e n -c irc u it or ground fa u lts detected during the test.
- T here sh all be no e vidence o f m ajor visual d efects, as defined in C lause 8;
- The fu n ctio n in g req uirem en ts o f 11.2 shall be met.
11.13.1 Purpose
The purpose o f th is te st is to dete rm ine the a b ility o f the co m p on en t to w ithstan d the e ffects o f
long-term pen etra tion o f hum idity.
11.13.2 P rocedure
The te st shall be carried out in accorda nce w ith IEC 6 00 68 -2 -7 8 w ith the fo llo w in g provisions.
a) P reconditioning
The com ponent, being at room te m p era ture , shall be introduced into the te st cham ber.
b) S e verities
The h um id ity level shall be 85 % ± 5 %, the te st d uration 1 000 h, and the com ponent
te m p era ture w ithin ±2 °C o f the specified level in accorda nce w ith T able 4.
O utdoor, unprotected 85 °C
O utdoor, protected 75 °C
Indoor, unconditioned 55 °C
Indoor, conditioned Not required
c) R ecovery
The co m p on en t shall be su bm itted to a reco very tim e o f betw een 2 h and 4 h.
-6 8 - 62093 © C E I:2005
11.13.4 E xigences
11.14.1 O bjet
L’o b je t de cet essai est de d ete rm in e r si les bornes e t la fixa tion des bornes au com posant
su p p o rte ro n t des co n tra in te s te lle s que celles qui risq u e n t d 'e tre a pp liq uâ es au cours des
o pe ra tion s co uran te s d ’assem blage ou de m anip u la tion des com posants.
11.14.3 P rocedure
P r6 con dition n em en t: 1 h dans les co n d itio n s a tm o sph â riqu e s n orm alisâes pour les m esures et
I’essai.
Essai de tra ctio n : selon la CEI 6 0068-2-21, essai Ua, en pre na nt les d isp o sitio n s suivantes:
Essai de pliage: selon la CEI 600 68 -2 -2 1 , essai Ub, en pre na nt les d is p o s itio n s suivantes:
a) pour les co m p osa nts d o n t les bornes sont a nu, chaque borne d oit etre essayee com m e
ce lle s de type A;
b) si les bornes sont â l'in te rie u r d'une boîte de p rotection, on d o it a p p liq u e r la procedure
suivante:
62093 © IE C :2005 - 69-
A t the end o f the reco very tim e, rep ea t te sts 11.1 and 11.2.
11.14.1 Purpose
The purpose o f th is te st is to dete rm ine th a t the te rm in a ls and the a tta chm en t o f the term ina ls
to the co m p on en t w ill w ithstan d such stresse s as are like ly to be applied during norm al
a ssem bly o r handling ope ra tion s.
11.14.3 P rocedure
P recon dition ing : 1 h at standard a tm o sph e ric co nd itio ns fo r m easurem ent and test.
T en sile test: as d escrib e d in IEC 600 68 -2 -2 1 , te st Ua, w ith the fo llo w in g pro visio ns:
Bending test: as d escrib e d in IEC 6 0068-2-21, te st Ub, w ith the fo llo w in g p rovisions:
a) fo r co m ponents w ith exposed te rm in a ls, each term inal shall be te ste d as fo r type A
term inals;
b) if the te rm ina ls are enclosed in a p ro tective box, the fo llo w in g procedure shall be applied:
- 70- 62093 © C E I:2005
un câble de d im ension et de type recom m andâs par le fa b ric a n t du com posant, coupâ â la
lon gu eu r approprtee, d oit etre co nn ects aux bornes â l'in tâ rie u r de la boîte, en se
co n fo rm a n t aux procedures recom m andees du fa b ric a n t du com posant. Le câble doit
passe r dans le trou du p re sse-âtou pe , en prenant soin d 'u tilis e r to u t d is p o s itif fo urni pour
le serrage du câble. Le co uve rcle de la boîte d o it âtre rem is de façon sûre. Le com posant
d o it alo rs etre essaye com m e celui co m p orta nt des bornes de type A.
Essai de couple: selon la CEI 600 68 -2 -2 1 , essai Ud, en pre na nt les d is p o s itio n s suivantes:
Les ecrous ou les vis d o ive n t p ou voir etre d e sse rres par la suite, â m oins q u 'ils n 'a ie n t ete
sp eciale m e nt conçus p ou r une fixa tio n perm anente.
Un câble de d im ension et de type recom m andes par le fa b ric a n t du com posant, coupe â la
lon gu eu r a pp ro priee , d o it etre relie aux so rtie s du conn ecte u r; les essais qui d o ive n t etre
rea lise s so nt ceux a p p lica b le s aux bornes de type A.
11.14.5 E xigences
11.15.1 O bjet
L ’o b je t de cet essai est de d e te rm in e r I’a p titu d e des co m posants, a p p a re ils ou autres a rticles
d estin es a etre u tilise s et sto ckes dans des c o n d itio n s d ’hum idite elevee, lo rs q u ’ils sont
com bines aux va ria tio n s cycliqu es de te m p era ture et, en g eneral, p ro d u isa n t de la
co nd en satio n sur la surface de I’e prouvette.
11.15.2 P rocedure
a cable o f the size and type recom m ended by the com ponent m anufacturer, cut to a
suitab le length, shall be connected to the te rm ina ls inside the box using the
m an ufa ctu re r's recom m ended p rocedures. The cable shall be taken th ro ug h the hole o f
the cable gland, ta king care to utilize a ny cable clam p a rra n g e m e n t provided. The lid o f
the box shall be se curely replaced. The co m p on en t shall then be tested as fo r type A
term inals.
T orque test: as described in IEC 6 0068-2-21, te s t Ud, w ith the fo llo w in g pro visio ns:
The nuts o r screw s shall be capable o f being loosened a fte rw a rd s unless th ey are s p e cifica lly
designed fo r p erm a ne nt attachm ent.
A cable o f the size and type recom m ended by the co m p on en t m anufacturer, cu t to a suitable
length, shall be connected to the o utp ut end o f the co nn ecto r, and the te sts fo r typ e A
te rm in a ls shall be carried out.
11.15.1 Purpose
The purpose o f this te st is to dete rm ine the s u ita b ility o f com ponents, e qu ip m en t o r o the r
a rticles fo r use and sto ra ge u nder co nd itio ns o f high h um id ity when com bined w ith cyclic
te m p era ture changes and, in g eneral, producing co nd en satio n on the surface o f the
specim en.
11.15.2 P rocedure
The te st shall be carried out in accorda nce w ith IEC 6 00 68 -2 -3 0 w ith the fo llo w in g provisions:
T ableau 5 - Lim ites de tem p e ratu re po u r I’essai cycliq u e de ch aleu r hum ide
o
■&.
o
o
A l’intârieur, con d itio nn 6 Non requise
Le co m p osa nt d oit fo n ctio n n e r dans les c o n d itio n s les plus d e fa vo ra b le s co nce rn an t les
pertes internes de ch aleu r. C e lle s-ci d oiven t inclure au m oins les c o n d itio n s de charge
m axim ale et de puissance d ’entree m axim ale.
11.15.4 E xigences
O utdoor, unprotected 75 °C
O utdoor, protected 55 °C
Indoor, unconditioned 40 °C
Indoor, conditioned Not required
The co m p on en t shall operate u nder w orst-case c o n d itio n s co nce rn ing the interna l heat
losses. These shall at least include c o n d itio n s o f m axim um load and m axim um pow er input.
In the last cycle, the fu n ctio n in g te st fo r the co m p on en t (see 11.2) shall be done at the upper
te m p era ture level o f the cycle.
A t the end o f the reco very tim e, rep ea t te sts 11.1 and 11.2.
A n n exe A
(inform ative)
Les seuils suivants sont recom m andes â une te m p era ture e n v iro n na nte de 20 °C et une
co nce ntra tion en acides de 1,24 kg/l.
A d ’a utres co n ce n tra tio n s en acides, il fa u t que les se u ils requis so ie nt a ju ste s, conform em ent
aux s p e cifica tio n s du fa brican t.
NOTE 1 La lim ite in fe rie u re de la tension de deconnexion â charge faible est un m inim um absolu.
NOTE 2 Ces valeurs so n t e sse n tielle m e n t destinees aux co n trö le u rs de charge qui u tilise n t la tension de la
batterie com m e param etre principal pour I’alg o rith m e de com m utation. C ertains fa b rica n ts u tilise n t d’autres
param etres, par exem ple I'etat de charge.
62093 © IE C :2005 - 75-
Annex A
(inform ative)
The fo llo w in g th re sho lds are recom m ended at a surrou nd ing te m p era ture o f 20 °C and an acid
co nce ntra tion o f 1,24 kg/l.
A t o th e r acid co nce n tra tio n s, the required th re sh o ld s m ust be adjusted a ccordin g to the
m an ufa ctu re r's sp ecificatio ns.
NOTE 1 The low er lim it o f the low charge d isco n n ect voltage is an a bsolute m inim um .
NOTE 2 T hese values are prim a rily intended for charge c o n tro lle rs th a t use the b a ttery voltage as the main
param eter for the sw itching algorithm . Some m anufacturers use o th er param eters, e.g. state o f charge.
IEC Standards Survey
------------------------------------------------------------------------------------------------------------------------------------------ w
1 The IEC would like to offer you the best quality standards possible. To make sure that we
continue to meet your needs, your feedback is essential. Would you please take a minute
| to answer the questions overleaf and fax them to us at +41 22 919 03 00 or mail them to
. the address below. Thank you!
I or
I
i Thank you for your contribution to the standards-making process.
I
Nicht frankieren
Ne pas affranchir
Non affrancare
No stamp required
I REPONSE PAYEE
I SUISSE
I
| Custom er Service C entre (CSC)
. In te rn a tio n a l E le c tro te c h n ic a l C o m m issio n
■ 3, rue de Varem be
| 1211 GENEVA 20
Switzerland
I
Q1 Please report on ONE STANDARD and 06 If you ticked NOT AT ALL in Q uestion 5
ONE STANDARD O NLY. Enter the exact the reason is: (tick a ll that apply)
num ber of the standard: (e.g. 60601-1-1)
standard is out of date □
standard is incom plete □
standard is too academ ic □
02 Please tell us in w hat capacity(ies) you standard is too superficial □
bought the standard (tick a ll that apply).
title is m isleading □
I am the/a:
I m ade the w rong choice □
purchasing agent □ other ...............................................................
librarian □
researcher □
design engineer □
07 Please assess the standard in the
safety engineer □ follow ing ca teg ories, using
testing engineer □ the num bers:
m arketing specialist □ (1) unacceptable,
(2) below average,
o th e r......................................................
(3) average,
(4) above average,
(5) exceptional,
I work fo r/in /a s a:
(6) not applicable
(tick a ll th a t apply)
tim e lin e s s ............................................
m anufacturing □
q uality of w ritin g ................................
consultant □
technical c o n te n ts .............................
governm ent □
logic of arran ge m en t of contents .
te st/ce rtifica tio n fa cility □
tables, ch arts, graphs, fig u re s ......
public utility □ o th e r ....................................................
education □
m ilitary □
o th e r......................................................
08 I read/use the: (tick one)
n n n
This standard w ill be used for: French text only
(tick a ll that apply) English te xt only
both English and French texts
general reference □
product research □
product d esign/developm ent □
specifications □ 09 Please share any com m ent on any
tenders □ aspect of the IEC that you w ould like
us to know:
q uality assessm ent □
ce rtifica tion □
technical docum entation □
thesis □
m anufacturing □
other
not at all □
nearly □
fa irly well □
e xactly □
1 Enquete sur les normes
1
| La CEI ambitionne de vous offrir les meilleures normes possibles. Pour nous assurer
que nous continuons â repondre â votre attente, nous avons besoin de quelques
| renseignements de votre part. Nous vous demandons simplement de consacrer un instant
. pour repondre au questionnaire ci-apres et de nous le retourner par fax au
1 +41 22 919 03 00 ou par courrier a l'adresse ci-dessous. Merci !
1
1
1 Centre du Service Clientele (CSC)
Comm ission Electrotechnique Internationale
1 3, rue de Varembe
i 1211 Geneve 20
' Suisse
I
1 ou
I
Telecopie: CEI/CSC +41 22 919 03 00
■ Nous vous remercions de la contribution que vous voudrez bien apporter ainsi
1 â la Normalisation Internationale.
1
Nicht frankieren
Ne pas affranchir
l " - J
Non affrancare
No stamp required
1 REPONSE PAYEE
1 SUISSE
1
I
Q1 V euillez ne m entionner q u ’UNE SEULE Q5 C ette norm e râpond-elle â vos besoins:
NORM E et indiquer son num ero exact: (une se ule reponse)
{ex. 60601-1-1)
pas du tout □
a peu pres □
assez bien □
parfaite m en t □
78283 879239
ICS 27.160