80174-01
REVISION C,
MAY 1994
3300/10
POWER SUPPLY
OPERATION/MAINTENANCE
MANUAL
Power Supply 80174-01
NOTICE
READ THE FOLLOWING BEFORE INSTALLING OR OPERATING EQUIPMENT
Bently Nevada Corporation has attempted to identify areas of risk created by improper installation
and/or operation of this product. These areas of information are noted as WARNING or CAUTION for
your protection and for the safe and effective operation of this equipment. Read all instructions before
installing or operating this product. Pay particular attention to those areas designated by the following
symbols.
WARNING
High Voltage present
Could cause shock,
burns or death. CAUTION
Machine protection will be lost
Do Not touch exposed during calibration.
wires or terminals.
This document is intended for personnel who operate the 3300 Monitoring System. The procedures
ii
80174-01 Power Supply
FOREWORD
RELATED DOCUMENTS
SYMBOLS
Special symbols are used in the manual to illustrate specifics in the step-by-step process. For
example:
iii
Power Supply 80174-01
iv
80174-01 Power Supply
CONTENTS
2 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 Disassembly Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4 Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5 Performance Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7 Programmable Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
10 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
v
Power Supply 80174-01
vi
80174-01 Power Supply
1
Power Supply 80174-01
2
80174-01 Power Supply
2 OPTIONS
3
Power Supply 80174-01
3 DISASSEMBLY PROCEDURE
1. Loosen screws and pull regulator board from rack.
4
80174-01 Power Supply
3 DISASSEMBLY PROCEDURE [CONT.]
2. To get to transformer assembly and cabling, loosen 4 screws and pull Power Input Module out from
rack.
WARNING
High voltage is present at rear of
rack. Accidental contact with
exposed wiring and terminals
could cause serious injury to
personnel.
5
Power Supply 80174-01
4 FUSES
1. Primary Power Fuse is located on the Power Input Module.
2. Two secondary fuses are located on the Power Regulator Board. To get to the regulator board see
section 3.
6
80174-01 Power Supply
5 PERFORMANCE TESTING
7
Power Supply 80174-01
2. Loosen System Monitor Front Panel screws and move panel to the right. Observe LEDs 1 through
7 on the System Monitor circuit board.
CAUTION
-VT jumpers in System Monitor
and Power Supply must be set to
the same voltage (-18 Vdc or -24
Vdc) or SUPPLIES OK LED will
not go on.
8
80174-01 Power Supply
CAUTION
Disconnect primary power before
repairs or fuse replacement!
CAUTION
4. Disconnect rack from primary
AC power. Loosen Power Input Disconnect primary power before
Module screws and pull module removing or checking Power Input
away from rack as far as cables Module!
will allow, (see section 3).
Ensure that cabling between
module, power transformer
and backplane is correct and
properly secured. Also check
that correct input voltage plug
is selected.
9
Power Supply 80174-01
6. Measure DC voltage at test points on System Monitor Board. All Voltages should meet listed
tolerances.
10
80174-01 Power Supply
8. Pull one monitor at a time out from the rack to disengage monitor from backplane (approximately
2 inches). Observe System Monitor SUPPLIES OK LED after removing each monitor from rack.
11
Power Supply 80174-01
9. Remove one Signal Input Module at a time from the rear of rack. Observe System Monitor
SUPPLIES OK LED after removing each module from rack. (Do not reinstall monitors removed in
step 8 until problem has been isolated to a particular module).
WARNING
High voltage present. Accidental contact
with terminals or exposed wiring could
cause injury to personnel.
12
80174-01 Power Supply
1. To change input voltage option, disengage Power Input Module from the rack, (see section 3).
Connect cable from Transformer to appropriate connector on circuit board as indicated in the
following table.
WARNING
High voltage is present at rear of
rack. Accidental contact with
terminals or exposed wiring could
cause injury to personnel.
13
Power Supply 80174-01
7 PROGRAMMABLE OPTIONS
NOTE: Refer to System Monitor Manual for -VT jumper requirements on System Monitor Circuit
Board.
14
80174-01 Power Supply
3300/10 AC Power
Supply With Barriers . . . . . . . . . . . . . . . . . 101019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
15
Power Supply 80174-01
Serial Interface
Hermetic OK Relay 84039-02 *
* To order replacement parts, specify the complete part number, 3300/10 S GG S GG S GG,
and the replacement part number.
If the Power Supply has been modified, specify the modification number on the parts order. The
customer must set programmable options. If in doubt about the part number, call your Bently
Nevada Corporation representative before ordering.
20
80174-01 Power Supply
10 SPECIFICATIONS
POWER INPUT
220 Vac Option 190 to 250 Vac, Single Phase, 50 to 60 Hz, @0.3 A, maximum
ENVIRONMENTAL
21
Power Supply 80174-01
Power Supply
PWA Drawing . . . . . . . . . . . . . . . . . . . . 125040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Power Supply
Schematics . . . . . . . . . . . . . . . . . . . . . . 78423 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Power Supply
Assembly Drawing . . . . . . . . . . . . . . . . 78422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PLC Interface
Power Input Module
Schematic . . . . . . . . . . . . . . . . . . . . . . . 84040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
22
Power Supply 80174-01
INDEX
D
Disassembly Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
F
Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Field Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
I
Input Voltage Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
O
Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Programmable Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
P
Performance Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Power Supply Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Programmable Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
R
Recommended Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
S
Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
32