10.37 10.

37
1.00 0.86 2.50 3.00 1.00 1.00 2.87 2.50 3.00 1.00 GENERAL:
1.00 1.87 1.00 1.87 A. MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF 6. UNLESS OTHERWISE NOTED IN PLAN OR IN SPECIFICATIONS, CAMBER ALL BEAMS AND
WF THE BUILDING CODES: GIRDERS AT LEAST 6.2MM FOR EVERY 3.00M SPAN EXCEPT CANTILEVERS FOR WHICH
1.00 1. ACI 318 - 89 THE CAMBERS SHALL BE AS NOTED IN PLANS OR AS ORDERED BY THE DESIGNER, BUT IN

1.00

1.00

1.00
C2/F2 C2/F2 C2/F2 C2/F2
C2 2B3 C2 2B3 C2 2B3 C2 2. AISC 1989 NO CASE LESS THAN 16.7MM OF EVERY 3.00M OF FREE SPAN.
3. NSCP 1992
TB1 TB1 B. ALL DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES

TB1
TB1

2B1

2B4
CONCRETE SLAB:
1.97

1.97
C. FOR ALL OTHER REQUIREMENTS, REFER TO ARCHITECTURAL, SANITARY,

WF

2B1
C1/F1 2S1 2S1

TB1

2B1
C2/F2 ELECTRICAL AND MECHANICAL WORKING DRAWINGS.

3.00

3.00
TB1

2B1
2S1
2B1 C1 1. ALL REINFORCEMENT SHALL BE 0.019M CLEAR MINIMUM FROM TOP AND BOTTOM OF
C1/F1 C2
C1/F1 SLAB.
TB1 2B1 FOOTINGS:
1.03

1.03
2S1 2. FOR TWO - WAY SLAB ALONG THE LONGER SPAN SHALL BE PLACED BELOW THOSE
C1 C1
1. FOOTING ARE DESIGN TO REST ON SOIL WITH A BEARING CAPACITY OF 72 KPa ALONG THE LONGER SPAN AT CENTER AND OVER THE LONGER SPAN BARS NEAR THE

TB1

2B1
TB1 2B3
TB1

2B3 2B3 2. NO FOOTING SHALL REST ON FILL SUPPORT UNLESS OTHERWISE INDICATED OR SHOWN IN DETAILS THE SPACING OF THE

1
2B
3. MINIMUM CONCRETE PROTECTION FOR REINF. SHALL BE 0.076M CLEAR FOR BARS AT THE COLUMN STRIPS CAN BE APPROXIMATELY 1 1/3 OF THE MIDDLE STRIP IN

TB1
2.00

2.00

2.00

2.00
2B4

2B3
2B1
C3/F3 C2/F2 C1/F1 2S1 CONCRETE DEPOSITED AGAINST THE GROUND AND 0.051M CLEAR FOR NO CASE GREATER THAN 2 1/3 TIMES THE SLAB THICKNESS.
2B4 CONCRETE DEPOSITED AGAINST THE FRAMEWORK UNLESS OTHERWISE DETAILED IN CONDITIONING SLAB HAVING SAME REINFORCEMENT
C3
12.00

12.00

12.00

12.00
C2
C1 RUNNING IN ONE DIRECTION, REINFORCING SHALL BE BEND, EXTENDED OR CUT AS
TB1 TB1 2B1 2B1 C1 2B1 FOLLOW.
CONCRETE MIXES & PLACINGS:
C1/F1 1. UNLESS OTHERWISE SPECIFIED, THE MIN. 28DAY CYLINDER COMPRESSIVE
TB1

TB1

2B1

2B1

2B3
3.60

3.60

3.60

3.60
TB1

STRENGTH ARE AS FOLLOWS.

2B3

2B1
2S1 2S1
2S1 FOOTINGS ------------------------------------------------------------------- 20.68 MPa
C4/F4 C1/F1 COLUMN ----------------------------------------------------------------------20.68 MPa
C2/F2
C1 BEAM, SLAB, CONC. TOPPING --------------------------------------- 20.68 MPa
C4 C2 R.C. STAIRS ----------------------------------------------------------------- 20.68 MPa
TB1 TB1 2B2 2B1 BEDDED SLABS, CATCH BASINS & SIDE WALK ---------------- 17.50 MPa

2B3
2S1

2.40
2.40

2.40

2.40
2B3

2B1
2S1 2B3 2. ALL CONCRETE MUST BE DEPOSITED, VIBRATED AND CURED IN ACCORDANCE
100mm THK CONCRETE SLAB WITH ACI STANDARD
WITH 10mm TEMP BARS @ 400 CTS B.W. 3. STRIPPING OF FORMS AND SHORES SHALL BE AS FOLLOWS:
C5 C6 FOUNDATIONS ----------------------------------------------------------------- 1 DAY
C5/F5 C6/F6 2B1 COLUMNS & WALLS ---------------------------------------------------------- 3 DAYS
BEAMS & GIRDER ------------------------------------------------------------- 21 DAYS 3. TEMPERATURE BARS FOR SLAB SHALL BE GENERALLY PLACED NEAR THE TENSION FACE
5.30 4.07 1.00 5.30 4.07 1.00
SLAB ------------------------------------------------------------------------------- 17 DAYS AND SHALL NOT BE LESS THAN 0.025 BT.
10.37 10.37
4. UNLESS OTHERWISE NOTED, ALL BEDDED SLAB BE REINFORCED WITH 10MM Ø BAR AT
4. CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT 0.25M O.C. E.W. AT CENTER OF SLAB. CONSTRUCTION JOINT FOR SLAB SHALL NOT BE
SEGREGATION RE-HANDLING OR FLOWING, PLACING SHALL BE DONE MORE THAN 3.00M APART.
1 FOUNDATION PLAN 2 2ND FLOOR FRAMING PLAN PREFERABLY WITH BUGGIES, BUCKETS OR WHEEL BARROWS, NO CHUTES
WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS TO
5. PROVIDE EXTRA REINFORCEMENT AT CORNER SLAB (TWO ADJACENT DISCONTINEOUS
EDGE) AS SHOWN BELOW.
S1 SCALE 1:100 MTS S1 SCALE 1:100 MTS
BUGGIES, WHEEL BARROWS OR BUCKETS IN WHICH CASE THEY SHALL NOT 6. PROVIDE SUPPLEMENTARY REINFORCEMENT AT SMALL UNFRAMED OPENINGS IN FLOOR
EXCEED 6.00M IN AGGREGATE LENGTH. NO DEPOSITING OF CONCRETE SHALL SLABS AS SHOWN BELOW.
BE ALLOWED WITHOUT THE USE OF VIBRATORS UNLESS AUTHORIZED IN
WRITING BY THE DESIGNERS AND ONLY FOR USUAL CONDITIONS. WHERE
VIBRATORS IS EXTREMELY DIFFICULT TO ACCOMPLISH.
CONCRETE HOLLOW BLOCK:
10.12
BEAMS: REINFORCEMENT AS TABULATED BELOW SHALL BE PROVIDED UNLESS OTHERWISE
2.57 2.49 2.49 2.57 1. CAMBER ALL BEAMS AND GIRDERS AT LEAST 6.2MM FOR EVERY 3.00M OF SPECIFIED IN THE PLAN.
0.80 0.80 SPAN
50X75X1.2mm C-PURLINS @600mm CTS 2. FOR TWO OR MORE LAYERS OF REINFORCING BARS, USED SEPARATORS
SPACED 0.914M O.C. AND IN NO CASE SHALL BE LESS THAN TWO (2) CONCRETE HOLLOW BLOCKS REINFORCEMENT
0.80

0.80

SEPARATORS.
BLOCK REINFORCEMENT NOTES
3. NO SPLICE SHALL BE PERMITTED ON BEAM AND GIRDERS WHERE CRITICAL
2.57

2.57

HT2
BENDING STRESSES OCCUR. TENSION SPLICE SO PERMITTED SHALL BE 48 THK. HORIZONTAL VERTICAL A. MIN. SPLICE AT LAP=0.25m

HT2
RB1 RB1
DIA. FOR PLAIN BARS AND 40 DIA. FOR DEFORMED BARS. LAP SPLICES SHALL B. PROVIDE RIGHT ANGLE
RB1

RB1

BE WIRED TOGETHER SPLICE TOP BARS AND MIDSPAN, BOTTOM BARS AT 0.076m 10mm Ø @ 0.61m O.C. 10mm Ø @ 0.61m O.C. REINFORCEMENT AT CORNER
HT2 HT2
RB1

SUPPORT. BEND BARS AT BEND POINTS IN SUPER STRUCTURE. WELDED 0.914 METER LONG
SPLICES SHALL BE DEVELOPED IN TENSION AT LEAST 125% OF THE SPECIFIED 0.102m 10mm Ø @ 0.61m O.C. 10mm Ø @ 0.61m O.C. C. WHERE CHB WALLS ADJOIN-
ING COL. R.C BEAM, WALL

TR1
RB1 H YIELD STRENGTH OF THE BARS NOT MORE THAN 50% OF THE BARS AT

T3
T3 0.152m 10mm Ø @ 0.61m O.C. 10mm Ø @ 0.61m O.C. DOWEL W/ SAME SIZE AS
2.57

2.57

ANYONE SECTION SHALL BE PERMITTED TO BE SPLICE

H
RB1

4. IF BE REINFORCING BARS END IN A WALL, THE CLEAR DISTANCE FOR THE VERT. OR HOR. REINFORCE-
0.208m 10mm Ø @ 0.61m O.C. 10mm Ø @ 0.61m O.C. MENT SHALL BE PROVIDED.
RB1

HT1 BARS TO THE FURTHER FACE OF THE WALL SHALL NOT BE LESS THAN 0.051
HT1
10.28

10.28

EMBEDMENT LENGTH SHALL BE 40 DIA. FOR COMPRESSION BARS.


5. MINIMUM CONCRETE PROTECTION OF REINFORCING BARS OR SHAPES SHALL
CONCRETE COLUMN:

DISTANCE (MIN.)
BE AS SHOWN:

25mm CLEAR
2.57

2.57

RB1 RB1
T3 COLUMN TIES SHALL BE PROTECTED EVERYWHERE BY A COVERING OF CONCRETE CAST
H
H
T3
MONOLITHICALLY WITH THE CORE OF MIN. THICKNESS OF 0.0127m AND NOT LESS THAN
RB1

1/2 TIMES MAX. SIZE OF COARSE AGGREGATE WHERE COLUMNS CHANGE IN SIZE.
RB1

RB1

HT2 HT2 VERTICAL REINFORCEMENT SHALL BE OFFSET AT A SLOPE OF NOT MORE THAN 0.025. AN
EXTRA 12mm Ø AT 0.076mm O.C. SHALL BE PROVIDE THROUGHOUT THE OFFSET REGION.
HT2
HT2
2.57

2.57

0.914MM O.C. 37.7MM CLR.


DISTANCE FOR BEAMS & GIRDERS
0.80

0.80

DISTANCE(MIN.)
RB1 RB1

STEEL DECKING:
37.7mm CLR.
C F 5pcs. x 1.475m
0.80 0.80
A 9pcs. x 3.425m 14pcs. x 2.325m
6pcs. x 1.30m
2.57 2.49
10.12
2.49 2.57 5pcs. x 3.60m D 9pcs. x 1.575m
G 13pcs. x 1.10m
4 ROOF FRAMING PLAN B E 8pcs. x 1.575m
S1 SCALE 1:100 MTS 25mmØ BAR SEPARATOR
15pcs. x 3.125m H 13pcs. x 0.90m

3 ROOF BEAM FRAMING PLAN


S1 SCALE 1:100 MTS

DESIGNED BY: ARCHITECT / ENGINEER: PROJECT TITLE: SHEET CONTENTS: OWNER: SHEET NO.

FOUNDATION PLAN
PROPOSED FOUR-BEDROOM
J. B. BASILIO JEROME B. BASILIO TWO - STOREY RESIDENCE
SECOND FLOOR FRAMING PLAN
ROOF BEAM FRAMING PLAN
MR. & MRS. VICTOR GALANG
223 SAN VICENTE STO. TOMAS, PAMPANGA
CELL NO. 0932 190 9496 PTR. NO.: DATE: PLACE: LOCATION:
ROOF FRAMING PLAN
GENERAL NOTE ADDRESS: MALPITIC, CITY OF SAN FERNANDO, PAMPANGA.
S-1
E-MAIL. jerome_618@yahoo.com
PRC. NO.: TIN. NO.: LOT 15, BLOCK 2, CONS.- SUB., MALPITIC, SAN FERNANDO, PAMPANGA REVISIONS/ REMARKS: