The document provides instructions for connecting cable from a TriMetric device to a battery in 3 steps:
1. Remove the fuse from the fuse holder on the TriMetric device.
2. Connect the 4 wires from the cable to the battery terminals according to the diagram, with the white wire to the Kelvin terminal nearest the battery's negative terminal.
3. Connect the other end of the 4-wire cable to the TriMetric's terminal block according to the labeling in the diagram and notes.
The document provides instructions for connecting cable from a TriMetric device to a battery in 3 steps:
1. Remove the fuse from the fuse holder on the TriMetric device.
2. Connect the 4 wires from the cable to the battery terminals according to the diagram, with the white wire to the Kelvin terminal nearest the battery's negative terminal.
3. Connect the other end of the 4-wire cable to the TriMetric's terminal block according to the labeling in the diagram and notes.
The document provides instructions for connecting cable from a TriMetric device to a battery in 3 steps:
1. Remove the fuse from the fuse holder on the TriMetric device.
2. Connect the 4 wires from the cable to the battery terminals according to the diagram, with the white wire to the Kelvin terminal nearest the battery's negative terminal.
3. Connect the other end of the 4-wire cable to the TriMetric's terminal block according to the labeling in the diagram and notes.
STEPS FOR CONNECTING CABLE FROM Maximum length of cable from
TRIMETRIC TO BATTERY. TriMetric to Battery:
Also refer to diagram in TriMetric (Part 1) With #22 gauge: up to 100 feet. instructions, last page. With #18 gauge: up to 300 feet. Instructions for connecting With #18 gauge, up to 500 feet is ok if 1. Remove fuse from fuseholder (below). another wire is paralleled with G1. cable to TriMetric end: 2. Connect 4 wires as shown (below) at shunt/battery end. 3. Connect 4 wires as shown to the TriMetric terminal block as 1. Find black paired with white: described (right) on this sketch. 2. Connect black paired with white to G2. 4. Make a final check of the wiring. 3. Connect white to SIG. 5. Install fuse in fuseholder. TriMetric digits should light. 4. Find black paired with red 5. Connect black paired with red to G1. 6. Connect red to +.
Battery/shunt end TriMetric end
Designations on TriMetric terminal block 5/32 clearance ring 2 feet stripped connectors Unstripped (White) to KELVIN (TriMetric end) terminal nearest white White minus (-) terminal Long length of 4 or 6 SIG of battery. conductor cable from Black G2 Black TriMetric to battery. (2 blacks) to KELVIN terminal away from Black Black G1 minus (-) terminal of battery. Red + TO + Terminal on battery. Red 3/8 clearance ring connector Fuseholder with 1A fast blow fuse (3AG size) a few inches #14 wire.
NOTES FOR CONNECTING TRIMETRIC TO BATTERY AND SHUNT BOGART ENGINEERING 04/18/12