Professional Documents
Culture Documents
1. Conventions........................................................................................................................... 2
Under the copyright laws, this manual cannot be reproduced in any form without prior written
permission of TOSHIBA TEC CORPORATION. No patent liability is assumed, however, with
respect to the use of the information contained herein.
SME090011A0
R090321H5901-TTEC
1. Conventions
1. EFMS (e-BRIDGE Fleet Management System)
The term “e-BRIDGE Fleet Management System” is called “EFMS” in this manual.
e-STUDIO283c/353c/453c T410SY0*230
e-STUDIO353/453 T364SY0*231
The Generation Names and the Device Versions are used to identify the models in this
manual.
The System Firmware Version can be confirmed at the [Firmware] tab in the [Device
Management] dialog box.
Example:
“eB2 / Lower than V2.3“ for e-STUDIO520/600/720/850 indicates:
Generation Name: eB2
Device Version: V2.3
System Firmware Version: Lower than T390SY0*231
The following procedures describe how to enable the device functions via TopAccess to use
the network cloning and firmware update functions via EFMS.
The procedures differ depending on the model and version for devices.
1. Login with Admin account to TopAccess Administration page of target device, and enter
the following URL in the address bar of the browser.
http://<IP Address or Computer Name>:<Port Num>/TopAccess/Administrator/Setup/Cloning/setup.htm
<Example> http://100.111.222.1:8080/TopAccess/Administrator/Setup/Cloning/setup.htm
2. If [Cloning Function ON/OFF] is set to [OFF], select [ON] and click [Save].
¨ The default value is [OFF]. Be sure to set [ON].
¨ Also set the other items as required for security.
2.1.1.2 Settings for the Data Cloning Function and the SOAP/XML Interface
1. Login to TopAccess Administration page and set to [Enable] for the [Data Cloning
Function] in the [Setup] – [General] page.
2. Login with Admin account to TopAccess Administration page of target device, and enter
the following URL in the address bar of the browser.
http://<IP Address or Computer Name>:<Port Num>/TopAccess/Administrator/Setup/Cloning/List.htm
<Example> http://100.111.222.1:8080/ TopAccess/Administrator/Setup/Cloning/List.htm
The following procedure describes how to set the Device Setting mode (08) to use the network
cloning and firmware update functions via EFMS.
* For detailed instruction of the Setting Mode (08) setting, please refer to the Service
Handbook for the device.
1. Press [0] and [8] keys at the same time and turn ON the power of the device.
1. Display the [Device Management] dialog box and confirm that [register trap address] in
the Alerting tab for each device.
¨ If [register trap address] is checked, see Step 2 or Step 3.
¨ If [register trap address] is unchecked, you do not have to confirm the setting.
3. When the device is removed from EFMS or [register trap address] is checked ON/OFF:
3-1. Click [SNMP Network Service] to display the SNMP Network Service setting page.
3-2. Delete the IP address of the EFMS server or change it with 0.0.0.0 entered in [IP
Trap Address 1 to 10].