EKMC Chilled-water Type Rack Air
EKMC Air-cooled Type Rack Air Conditioner
Conditioner
Model
Model EKMC08 Fan quantity
Maximum cooling capacity 8.8 Rated air flow (80% RPM)
Rated cooling capacity 8 Sound level
Fan quantity 1 Maximum air flow (100% RPM)
Air flow 1900 Power supply
Power supply Maximum current
Maximum input current 21.5 Maximum power input
Coil material Copper tube + Aluminum fin Power input (maximum air flow)
Refrigerant Power input (rated air flow)
Liquid/gas pipe diameter (copper pipe) 9.52/15.88 Total cooling capacity (rated air flow)
Condensate pump pipe (optional) 6mm PE 6mm PE 6mm PE Total cooling capacity (maximum air flow)
Running weight 55 Coil rows
Dimension (HxWxL) 439 440*440*903 903 903 Chilled water flow
Matched ODU EKMC08A1W Water pipe size
Maximum input current of ODU 18.5 Transport weight
ODU power supply Unit weight
ODU weight (single set) 105 Operating weight
ODU dimension (WxDxH) 1100*430*810 Dimension (HxWxL)

Note: entering/leaving 7/12°C, return air temp. 38°C, supply air temp. 24°C (the ser ver entrance). Rated air flow: at 80% RPM; maximum
Note:
air flow: at 100% RPM
1. Test condition, indoor D.B. temp. 38°C, 25% RH, and D.B. temp. 35°C.
2. The equivalent longest connecting pipe of EKMC04 IDU and ODU is 20 m.
3. The equivalent longest connecting pipe of EKMC08/15/30 IDU and ODU is 30 m. The equivalent longest connecting pipe distance can reach 50 m when the size of EKMC Air-cooled Type Inter-
gas pipe diameter increases by one unit. column Air Conditioner
4. For the level difference between IDU and ODU, if the ODU is installed above IDU, an oil deposit elbow needs to be installed for ever y 6 m.
5. The normal operating range of the unit for cooling is -15°C to +48°C. Model EKMC25 EKMC39 EKMC25 EKMC39
Air supply mode Back air return and front air supply; an air deflector with adjustable direction can be configured on the field to realize a lot of air supply modes such as
front horizontal air supply, horizontal air supply on the left side, horizontal air supply on the right side, and horizontal air supply on both the left and right sides
Circulating air flow m3/h 5000 8200 5000 8200
EKMC Chilled-water Type Total cooling capacity kW 25 38.1 25 38.1
Inter-column Air Conditioner Sensible cooling capacity kW 25 38.1 25 38.1
Refrigerant type R410A
Model EKMC25H(42U) EKMC25H(46U) EKMC25H(52U) EKMC50H EKMC70H
Compressor type Enclosed Scroll Compressor Enclosed Scroll EC Compressor
Back air return and front air supply; an air deflector with adjustable direction can be configured on the field to realize a lot of air supply modes such
Air supply mode Expansion valve type Mechanical thermostatic expansion valve Electronic expansion valve
as front horizontal air supply, horizontal air supply on the left side, horizontal air supply on the right side, and horizontal air supply on both the left and right sides
Fan quantity 6 2 6 2
Cooling capacity of inlet water 7°C/outlet water 12°C kW 33.9 35.4 42.5 49.5 69.3
Fan type Directly-connected EC fan
Cooling capacity of inlet water 12°C/outlet water 18°C kW 25.3 26.1 31.3 37.6 53.6
Air filter G4 filter
Circulating air flow m3/h 4300 4300 5000 7000 11000 Power supply 380V/3N~/50Hz
Water valve type Two-way valve for the standard configuration; three-way valve optional Power distribution parameters FLA (A)(cooling only) A 23.8 27.9 23.8 27.9
Fan type Directly-connected EC fan Power distribution parameters FLA (A)(constant temperature and humidity) 28.3 37 28.3 37
Air filter G4 filter Optional heating capacity kW 3 6 3 6
Power supply 220V/~/50Hz 220V/~/50Hz 220V/~/50Hz 380V/3N~/50Hz 380V/3N~/50Hz Optional humidifying capacity kg/h 2 2 2 2
Power distribution parameters FLA (cooling only) A 3.8 3.8 4.5 3.5 5.2 Humidifier water inlet pipe (available for the humidifying type only) G1/2 G1/2 G1/2 G1/2
Power distribution parameters FLA (constant temperature and humidity) A 18.3 18.3 19.0 12.5 14.2 Condensate water drainage pipe mm 20 20 20 20
Optional heating capacity kW 3 3 3 6 6 Refrigerant gas pipe mm 19 22 19 22
Optional humidifying capacity kg/h 2 2 2 2 2 Refrigerant liquid pipe mm 16 19 16 19
Humidifier water inlet pipe G1/2 G1/2 G1/2 G1/2 G1/2 Unit weight kg 310 400 290 380
Condensate water drainage pipe mm 20 20 20 20 20 Dimension (WxDxH) mm 300*1100*2000 600*1100*2000 300*1100*2000 600*1100*2000
Chilled water inlet and outlet pipe in 1 1 1 1 1/2 1 1/2 EKMC10Y1STCT EKMC15Y1STCT EKMC10Y1STCT EKMC15Y1STCT
Matched ODU
Dimension (WxDxH) mm 300*1200*2000 300*1200*2200 300*1200*2500 600*1200*2000 600*1200*2000 -ACS42 -ACS72 -ACS42 -ACS72
ODU power supply 380V/3N~/50Hz
Note: ODU fan quantity 1 2 1 2
1. Test condition, return air temp. 37°C, 24% RH.
Refrigerant pipe size φ22/φ16 φ28/φ22 φ22/φ16 φ28/φ22
2. The power distribution parameters are configured depending on the maximum current of standard unit configuration for power supply configuration.
3. The unit depth is optional: 1100 mm. Dimension (LxWxH) 1360*968*661 1860*1273*655 1360*968*661 1860*1273*655
4. Two-way valve is equipped for the water flow control of standard unit, three-way valve is optional.
Note: 1. Test condition, return air temp. 37°C, 24% RH, condensation temp. of air-cooled/water-cooled/ethylene glycol-cooled type 45°C.
5. If any parameter is not listed in the data table, please contact EK.
2. The power distribution parameters are configured depending on the maximum current of standard unit configuration for power supply
configuration (air-cooled ODU current excluded).
3. The ODU can be installed horizontally or vertically, and the dimensions in the table exclude the supporting leg height; cr yogenic
components should be added when the unit operates below -15°C.
4. If any parameter is not listed in the data table, please contact our company.