PRODUCT SPECIFICATIONS

Model 51i Total Hydrocarbon Analyzer


Flame ionization for the detection of total hydrocarbon

The Thermo Scientific™ Model


51i Total Hydrocarbon (THC)
Analyzer combines proven Flame
Ionization Detector (FID) technology,
easy to use menu-driven firmware,
and advanced diagnostics to
offer unsurpassed flexibility and
reliability. The Model 51i Analyzer is
available in low temperature and
high temperature versions.

Features
• Flame Ionization Technology (FID) The Model 51i Analyzer uses a Flame This state-of-the-art gas analyzer also
measures organic gases & vapors Ionization Detector, or FID, to measure offers features such as an Ethernet port
• Adjustable ranges organic gases and vapors. FID is a and a flash memory for increased data
well-known technology that has been storage. Ethernet connectivity provides
• Real-time correction of THC readings
used in laboratories and industry for effi cient remote access, allowing the
• Ethernet port and flash memory offer many years. Flame Ionization Detectors user to download measurement information
efficient global access are highly efficient; providing a wide directly from the instrument without having
linear range and sensitive detection of to be on-site.
Introduction organic compounds.
The Thermo Scientific Model 51i Easily programmable short-cut keys

Total Hydrocarbon (THC) Analyzer This state-of-the-art gas analyzer offers allow you to jump directly to frequently

combines proven Flame Ionization features such as an Ethernet port as accessed functions, menus or screens.

Detector (FID) technology, easy to use well as flash memory for increased The larger interface screen can display

menu-driven firmware, and advanced data storage. up to five lines of measurement information

diagnostics to offer unsurpassed flexibility while primary screen remains visible.

and reliability. The Model 51i Analyzer


is available in low temperature and high
temperature versions.

Thermo Scientific™ Model 51i Total


Hydrocarbon Analyzer
Thermo Scientific Model 51i Total Hydrocarbon Analyzer Ordering information
Specifications Model 51i-HT Total Hydrocarbon Analyzer
Preset ranges 0-1, 10, 100, 1,000, 5000, and 10000 ppmc Choose from the following configurations/options
to customize your own Model 51i-HT Analyzer
Custom ranges 0-1 to 10000 ppmc
1. Voltage options
Zero noise 0.025 ppmc RMS (10 second averaging time)
A = 120 VAC 50/60 Hz (standard)
Minimum detectable 0.050 ppm (10 second averaging time) B = 220 VAC 50/60 Hz
Zero drift (24 hour) < 0.50 ppm J = 100 VAC 50/60 Hz
Span drift (24 hour) < 2% of range or 0.20 ppm (whichever is larger) 2. Internal zero/span
Response time (90%) 15 seconds at 1 second averaging time M = No internal zero/span, mixed fuel
Precision 2.0% of reading or 0.1 ppm (whichever is larger) N = No internal zero/span, hydrogen fuel

+/-2.0% of span (at concentrations Y = Internal zero/span, mixed fuel


Linerarity
of 10% to 150% of span) Z = Internal zero/span, hydrogen fuel
3. Optional I/O
Sample flow rate 0.75 to 1.50 lpm nominal
A = None (standard)
Makeup air flow rate 150 ccm to 300 ccm hydrocarbon free air
C = I/O expansion board (4-20mA outputs – 6 channels,
10 to 35 ccm hydrogen or 50 to 0-10v inputs – 8 channels)
Fuel flow rate
120 ccm H2/He mixture 4. Mounting hardware
59°-95°F (15°- 35°C), safely operated A = Bench mounting and ears/handles, EIA
Operating temperature
32°-113° F (0°-45° C)
Your Order Code: Model 51i -HT
100 VAC, 115 VAC, 220-240 VAC
Power requirements
+/-10%, 50/60Hz, 420W

Size and weight 16.75" (W) × 8.62" (H) × 23" (D), 50 lbs. (22.7 kg)
Model 51i-LT Total Hydrocarbon Analyzer
Selectable voltage, RS232/RS485, TCP/IP, 10 Choose from the following configurations/options
Outputs status relays, and power fail indication (standard). to customize your own Model 51i-LT Analyzer
0-20 or 4-20 mA isolated current output (optional)
1. Voltage options
16 Digital Inputs (standard), 8 0-10 Vdc A = 120 VAC 50/60 Hz (standard)
Inputs
Analog Inputs (optional) B = 220 VAC 50/60 Hz
J = 100 VAC 50/60 Hz

To maintain optimal product performance, you need immediate access 2. Internal zero/span
to experts worldwide, as well as priority status when your air quality N = No internal zero/span, hydrogen fuel
equipment needs repair or replacement. We offer comprehensive, Z = Internal zero/span, hydrogen fuel
flexible support solutions for all phases of the product life cycle. Through
3. Optional I/O
predictable, fixed-cost pricing, our services help protect the return on
A = None (standard)
investment and total cost of ownership of your Thermo Scientific products.
C = I/O expansion board (4-20mA outputs – 6 channels,
0-10v inputs – 8 channels)
USA India
27 Forge Parkway C/327, TTC Industrial Area
4. Mounting hardware
Franklin, MA 02038 MIDC Pawane A = Bench mounting and ears/handles, EIA
Ph: (508) 520-0430 New Mumbai 400 705, India
Fax: (508) 520-2800 Ph: +91 22 4157 8800 Your Order Code: Model 51i -LT
orders.aqi@thermofisher.com india@thermofisher.com

China Europe
+Units 702-715, 7th Floor Ion Path, Road Three,
Tower West, Yonghe Winsford, Cheshire CW73GA
Beijing, China 100007 UK Ph: +44 1606 548700
Ph: +86 10 84193588 Fax: +44 1606 548711
info.eid.china@thermofisher.com sales.epm.uk@thermofisher.com

Find out more at thermofisher.com/cleanair