You are on page 1of 7

Washing of produce:

Guidance to minimize the microbiological risk

1
Table of contents

4 Purpose of this booklet


Content overview
Microbiological food safety for produce washing
5 Process overview
6 Water quality management
Pre-requisites for water quality
Verification programs
7 Generation and storage of chemicals
8 Management of the washing process
9 Maintenance of equipment
Calibrations & regular checks
Preventive maintenance
10 Validation and verification
In washing water
On produce
11 Record keeping
11 Good Manufacturing Practices (GMPs)
Zoning
Hygiene
Purpose of this booklet Process overview

Content overview Microbiological food safety for The drawing below represents an washing water are the main parameters
This booklet helps you to understand produce washing overview of the washing process. to consider for an effective management
the critical elements that impact Produce (e.g. salads, herbs, carrots, Generation and storage of chemicals of the process.
microbiological food safety during strawberries) can get contaminated with as well as concentration and pH of the
produce washing. pathogenic microorganisms during the
• Why is it important to manage the production in the field.
wash properly;
• What are the main elements to For a lot of produce, washing is
control during produce washing; the only process that can bring a
• What are the main elements to microbial reduction.
manage for an effective maintenance
of equipment; During washing, microorganisms are
• Why is it important to validate the removed from the produce surface by 5–15°C
microbial reduction for a washing mechanical action of the water. Once Dark
process. microorganisms are in the water, they
can be killed by the chemicals present. – Hypochlorite
– Chlorine Dioxide
The correct management of the – Peracetic Acid
washing process is extremely important
to maximize microbiological reduction
and avoid cross-contaminations Dosing
between washing water and produce.
Wash pH
mg/L

O3

H2O

Ozone Ozone
Generator Solution

1 2 3

4 5
Water quality management Generation and storage
of chemicals

Why is water quality so important? Verification programs: Why is How should chemical solutions be Hypochlorite Hypo Cl.
The use of potable water is a it important to verify the quality generated and stock solutions stored? Chlorine dioxide Cl. Diox
recommended pre-requisite to avoid of the water? The most commonly used chemicals for Peracetic acid PAA
additional microbial contamination of Verification programs should be the washing of produce are: Ozone Ozone
the produce. Guidelines for potable done according to HACCP plans. The
CHEMICAL RECOMMENDATIONS
water quality are published and most common parameter to check
regularly updated by the World Health for verification is Escherichia coli (or Hypo Cl. Concentrated solutions (15–20%) and calcium chloride
Organization (WHO) “Guidelines for alternatively coliforms) as an indicator of in powder state are commercially available
drinking water quality”1. However, local hygiene. For both parameters absence Cl. Diox Must be generated on-site shortly before use
requirements should be considered of microorganisms is required in 100 ml • Gas
when available. of water. • Highly volatile and unstable
• Explosive at high concentrations

GENERATION
• Generated from commercially available stabilized solutions
It is also important to reduce to a The frequency of sampling can be of sodium chlorite and sodium chlorate
minimum value the content of iron and defined internally depending on the • These solutions need to be activated on-site by addition
of hydrochloric acid or sulphuric acid.
manganese in the water. level of confidence present towards the Specific dosing systems are available to do so.
microbial safety of the water system
PAA Concentrated solutions (10–15%) are commercially available
These two elements react and consume and taking into account seasonality and
hypochlorite and as result lower the occasional events. Data collected over Ozone Due to its short half-life, ozone should be produced on site.
antimicrobial efficacy. time are very useful to build control • Produced from pure oxygen or dry air by corona discharge
of electricity (most cost effective) followed by direct introduction
charts and trend analyses. into water.

The following conditions are very important to avoid


Hypo Cl.
degradation and formation of chlorates!
Cl. Diox • Cool temperatures (5–15°C)
• Dark room or dark package into materials like Teflon, rubber,
PVC, PET or plastic
• Use within four weeks from production
• Avoid direct contact with carbon steel and stainless steel
• Sodium hypochlorite solutions should have a pH between 12 and 13.
The storage conditions of a solution with a specific concen-

STORAGE
tration should be validated to avoid degradation of chlorine
and formation of chlorates. A way to do the validation is to check
the chlorate concentration in the stock solution before and after
a specific storage time.

PAA To be stored in a cool environment (5–15°C) away from sunlight


• Commercially available solutions of 10–15% are much more stable
than higher and lower concentrated solutions
• The acid decomposition is roughly doubled
1 www.who.int/water_sanitation_health/publications/drinking-water-quality- by every 10°C increase.
guidelines-4-including-1st-addendum
Ozone Ozone cannot be stored!

6 7
Management of Maintenance of equipment
the washing process

Why is it important to monitor pH in the washing bath should be Why are appropriate calibration This consists of regular flushing using
chemical concentration and pH? continuously measured to prevent and maintenance important? solutions of sodium hydroxide or
Chemical concentration in the big variations that can deeply affect sodium hypochlorite.
washing bath should be continuously the disinfection efficacy Calibrations & regular checks • Whole plant. Regular inspection for
monitored to avoid drops in • Chemical dosing and measuring corrosion damage of joints, fittings
concentration systems. In order to properly manage and connections should be done on a
the chemical concentration and daily basis.
CHEMICAL CHEMICAL CONCENTRATION RECOMMENDATIONS maximize the produce sanitization, it
monitoring (how) concentration contact time pH
is important to regularly calibrate the Preventive maintenance
Hypo Cl. • Commonly used measuring 15–20 mg/L From • hypochlorite
systems are the Oxidation residual 30 seconds between two systems. This should be done • Chemical dosing and measuring
Cl. Diox Reduction Potential (ORP) chlorine to 2 minutes 6.5–7.2 according to a frequency advised by systems. Preventive maintenance
that measure the oxidation • chlorine the manufacturer and performed by is a key element to the proper
potential continously. This dioxide
parameter is directly linked between trained people. functioning of these devices and
to the concentration of the 4–9 • Water delivery to the measuring as consequence to the correct
oxidizer. system. It is important to verify management of the washing
• For chlorine dioxide the
use of electrochemical that the washing water is properly process. Replacement of spare
sensors is also delivered to the chemical measuring parts and frequency should follow
recommended. system. This check should be recommendations from the device
X • Colorimetric methods are
also available for chlorine done daily for accurate chemical manufacturer.
dioxide, easy to use but measurement. Most times the check • Whole plant. Replacement of
are not continous and less consists of visual verification that seals, flexible tubing, gaskets and
accurate.
connecting pipes are not clogged other wearing parts should be
PAA • Automated devices based 40–50 mg/L From Between 4–7 and that the exit flow is normal. done regularly depending on the
on selective membranes 30 seconds The delivery system should also be technology used but at least once a
are recommended for to 2 minutes
continous reading.
cleaned to avoid biofilm formation. year.

X • ORP methods are not


accurate due to the
reading interference with
Dosing Water Measuring
peroxide water.
delivery

Ozone • Electrochemical sensors 5 mg/L 2 minutes 6 is the


combined with selective optimal value pH
Wash
membranes can provide mg/L
continous reading of
residual ozone.
• To measure the ozone
concentration in the gas
stream before dosing into
the water, UV absorption
methods can be used.

8 9
Validation and verification Record keeping Good Manufacturing
Practices (GMPs)

Why is validation so important? Why is verification so important? Why is it important to store Why is it important to have GMPs
Validation of the inactivation achieved • Verification should be done on both records? in place?
during washing (in both water washing water and produce at an Records show evidence that a specific GMPs (as defined by CODEX - General
and produce) is key to understand appropriate frequency. action has been taken at a specific Principles of Food Hygiene) are a
the efficacy of the process. • Escherichia coli or coliforms as time. Therefore it is important to collection of generally recognized rules,
representatives of pathogenic collect them in a timely manner and procedures and practices that together
This value must be directly linked bacteria such as Salmonella and keep them over time. A person should provide guidelines stating what is and
to the free chemical concentration Shiga Toxin Producing Escherichia coli be responsible to do so. what is not acceptable in the food
in the washing water and the chemical (STEC) and target pathogens should industry. GMPs must be preventive in
parameter continously monitored be used. The following elements are the most their approach. They ensure that food
(e.g. ORP). • Analytical data should be collected important for the washing process and quality and food safety objectives are
over a defined period of time. This should be kept: met consistently.
allows the possibility to do trend
Washing water
Disinfection in the analysis and better control the process.
Storing temperature Zoning
washing water should and time (where
achieve at least Zoning is the
applicable) of the separation of areas
3 log10 reduction concentrated solution
of the target with different
microorganism during hygiene levels. It
a full scale washing can be applied to
process. This is done prevent spreading
by comparing inactivation in water measured of microorganisms
with and without chemical. The enumeration Chemical from a specific
of Escherichia coli (or alternatively coliforms) in concentration in the highly contaminated area to other more critical
water should be used to assess the inactivation washing water processing zones. As an example, raw material
of pathogenic microorganisms. reception should be separated from the packing
area of the washed finished product.

Produce Cleaning
Decontamination of Cleaning must
produce cannot fully be considered as
pH of the washing a process step,
remove the target water
microorganism. A preparing the line
1–2 log10 reduction for production. Wet
can be considered cleaning describes
successful. Similarly the process of
to water, the soil removal from
enumeration of Escherichia coli (or alternatively equipment and/or manufacturing process
coliforms) can be used to assess the inactivation facilities, with the use of water.
of pathogenic microorganisms. This is done Validation and
by enumeration of microorganisms before and verification data for Cleaning is a mandatory action to keep the
after washing. both water hygiene of the equipment and process facilities
and produce under control.

10 11