0% found this document useful (0 votes)
63 views2 pages

SEC Auto Test Chamber

This document provides specifications for the DIN 75220 Automotive Component Test Chamber. It has interchangeable glass filters and luminaries that slide in and out for access. It provides full spectrum solar simulation according to AM 1.5 CIE 85 Table 4. It is available in 3 sizes, with metal halide global lamps ranging from 2500W to 4000W. The chambers can generate temperatures from -30°C to +100°C with humidity control from 20-80% or 30-95% depending on whether radiation is on or off.

Uploaded by

Markus Jeremia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views2 pages

SEC Auto Test Chamber

This document provides specifications for the DIN 75220 Automotive Component Test Chamber. It has interchangeable glass filters and luminaries that slide in and out for access. It provides full spectrum solar simulation according to AM 1.5 CIE 85 Table 4. It is available in 3 sizes, with metal halide global lamps ranging from 2500W to 4000W. The chambers can generate temperatures from -30°C to +100°C with humidity control from 20-80% or 30-95% depending on whether radiation is on or off.

Uploaded by

Markus Jeremia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

DIN 75220 Automotive Component Test Chamber

With interchangeable glass filter capability


Luminaries slide in and out , access to
window glass filter and lamp Full spectrum solar simulation AM 1.5 CIE 85 Table 4
SPD AM1.5G (CIE 85T4) vs. MHG w. ODF-Filter
8% 52% 40%
2500

2000

1500
mW/m²*nm

MHG/ODF
AM1.5G

1000

500

0
305

405

505

605

705

805

905

1005

1105

1205

1305

1405

1505

1605

1705

1805

1905

2005

2105

2205

2305

2405
3 Sizes Available Wellenlänge (nm)

Specification SEC 600 SEC 1100 SEC 2100


Metal Halide Global Lamp 2500 Watt x 1 4000 Watt x 1 4000 Watt x 2
2 2
Luminary Output 800-1200 W/m 800-1200 W/m 800-1200 W/m2
Target Area (Irradiated) 650 x 600mm 850 x 800mm 1600 x 1000mm
Exposure Plane (Physical W x D x H) 0.8 x 0.8 x 0.95m 1.1 x 1.1 x 0.95m 2.1 x 1.2 x 1.6m
Chamber Volume 600L 1100L 4000L
Light 'ON' Temperature Range -20 to +100°C -20 to +100°C -20 to +100°C
Light 'OFF' Temperature Range -30 to +100°C -30 to +100°C -30 to +100°C
RH Range With Radiation 20-80% 20-80% 20-80%
RH Range With Out Radiation 30-95% 30-95% 30-95%

Atlas Test Chambers & Natural Weathering Test Services

Atlas Material Testing Technology a


Division of AMETEK
4114 N. Ravenswood Ave
Chicago, IL 60613
www.atlas-mts.com

Craig.Hazzard@ametek.com
Features
Luminary Technology
Color touch panel graphics user interface Square Shape for Better Uniformity
RS 232 data transfer capable
Galvanized steel + powder coated body Lamp MHG 4000
SUS 304 stainless steel inner testing chamber
Intelligent PID control of test parameters
Automatic alert system for maintenance and repair Side Reflector
Water level warning system and automatic refill
Main Reflector
Accuracy and Cooling
Temperature Accuracy: ± 1℃ Front Frame / Filter Glass
Temperature Uniformity: ± 2℃ removable and can be replaced
Humidity Accuracy: ± 5% with different automotive glass
Ramping Rate - Heat Up: 4.0℃/Min(W/O Radiation)
Ramping Rate- Cool Down: 2.5℃/Min(W/O Radiation)
Condensing Type: Air Cooled Type
Coolant: CFC Free R-404A
%- of Total Radiation (280-3.000nm)

19,70%
20,00% 19,19% 19,00%
18,37% 18,23% 18,27% 18,30%
17,66%

16,10%

14,90% 15,08%
15,00%

12,80%

DIN 75220 min.


10,00% MHG ODF
CIE 85 T4
DIN 75220 max. Square shape energy means
better uniformity over the test
5,00%
sample

0,00%
400-520 520-640 640-800

DIN 75220
SolarConstant 2500/4000 vs CIE 85 T4 (VIS-Range)
Indoor Test Ambient Temperature
2.500
MHG ODF
2.250 CIE 85 T4

2.000
Exposure Zone 1
1.750
e.g. dashboards,
back shelf
1.500
mW/m²*nm

1.250 Exposure Zone 2


1.000
e.g. door lining,
750
carpets
500
DIN 75220
250
Exposure Zone 1 = 80°C +/- 3 °C
-
Exposure Zone 2 = 65°C +/- 3 °C
401

421

441

461

481

501

521

541

561

581

601

621

641

661

681

701

721

741

761

781

Wellenlänge (nm)

Atlas Material Testing a Division of AMETEK


4114 N. Ravenswood Ave
Chicago IL 60613
www.atlas-mts.com

You might also like