DIN 75220 Automotive Component Test Chamber
With interchangeable glass filter capability
Luminaries slide in and out , access to
window glass filter and lamp Full spectrum solar simulation AM 1.5 CIE 85 Table 4
SPD AM1.5G (CIE 85T4) vs. MHG w. ODF-Filter
8% 52% 40%
2500
2000
1500
mW/m²*nm
MHG/ODF
AM1.5G
1000
500
0
305
405
505
605
705
805
905
1005
1105
1205
1305
1405
1505
1605
1705
1805
1905
2005
2105
2205
2305
2405
3 Sizes Available Wellenlänge (nm)
Specification SEC 600 SEC 1100 SEC 2100
Metal Halide Global Lamp 2500 Watt x 1 4000 Watt x 1 4000 Watt x 2
2 2
Luminary Output 800-1200 W/m 800-1200 W/m 800-1200 W/m2
Target Area (Irradiated) 650 x 600mm 850 x 800mm 1600 x 1000mm
Exposure Plane (Physical W x D x H) 0.8 x 0.8 x 0.95m 1.1 x 1.1 x 0.95m 2.1 x 1.2 x 1.6m
Chamber Volume 600L 1100L 4000L
Light 'ON' Temperature Range -20 to +100°C -20 to +100°C -20 to +100°C
Light 'OFF' Temperature Range -30 to +100°C -30 to +100°C -30 to +100°C
RH Range With Radiation 20-80% 20-80% 20-80%
RH Range With Out Radiation 30-95% 30-95% 30-95%
Atlas Test Chambers & Natural Weathering Test Services
Atlas Material Testing Technology a
Division of AMETEK
4114 N. Ravenswood Ave
Chicago, IL 60613
www.atlas-mts.com
Craig.Hazzard@ametek.com
Features
Luminary Technology
Color touch panel graphics user interface Square Shape for Better Uniformity
RS 232 data transfer capable
Galvanized steel + powder coated body Lamp MHG 4000
SUS 304 stainless steel inner testing chamber
Intelligent PID control of test parameters
Automatic alert system for maintenance and repair Side Reflector
Water level warning system and automatic refill
Main Reflector
Accuracy and Cooling
Temperature Accuracy: ± 1℃ Front Frame / Filter Glass
Temperature Uniformity: ± 2℃ removable and can be replaced
Humidity Accuracy: ± 5% with different automotive glass
Ramping Rate - Heat Up: 4.0℃/Min(W/O Radiation)
Ramping Rate- Cool Down: 2.5℃/Min(W/O Radiation)
Condensing Type: Air Cooled Type
Coolant: CFC Free R-404A
%- of Total Radiation (280-3.000nm)
19,70%
20,00% 19,19% 19,00%
18,37% 18,23% 18,27% 18,30%
17,66%
16,10%
14,90% 15,08%
15,00%
12,80%
DIN 75220 min.
10,00% MHG ODF
CIE 85 T4
DIN 75220 max. Square shape energy means
better uniformity over the test
5,00%
sample
0,00%
400-520 520-640 640-800
DIN 75220
SolarConstant 2500/4000 vs CIE 85 T4 (VIS-Range)
Indoor Test Ambient Temperature
2.500
MHG ODF
2.250 CIE 85 T4
2.000
Exposure Zone 1
1.750
e.g. dashboards,
back shelf
1.500
mW/m²*nm
1.250 Exposure Zone 2
1.000
e.g. door lining,
750
carpets
500
DIN 75220
250
Exposure Zone 1 = 80°C +/- 3 °C
-
Exposure Zone 2 = 65°C +/- 3 °C
401
421
441
461
481
501
521
541
561
581
601
621
641
661
681
701
721
741
761
781
Wellenlänge (nm)
Atlas Material Testing a Division of AMETEK
4114 N. Ravenswood Ave
Chicago IL 60613
www.atlas-mts.com