You are on page 1of 5
RAPID Lab ® 348 Blood Gas System Answer for life, When every second is critical for survival, which system would you rely on ? Choose a blood gas instrument that stands by you The RAPIDLab* 348s a Critical Care system that delivers maximum uptime, minimum, ‘operator involvement and fast, accurate results This provides you with ficiency and value to form a compact, easy-to-use system. With low maintenance and Siemens’ comprehensive range of support services and information systems, RAPIDLab* 348 Is. your critical care testing solution even for lower volume testing sites. RAPIDLab® 348 Specifications Renal Dialysate ‘This mode permits measurement of Na+, +, Cast and pH in bicarbonate-based or acetate-based renal dialysis uids Measured Barometric Pressure pati 400-825 mmlg 533-1100 ka ‘Sample Size Syringe: 95 ul, Capillary: 70 ul, Micro sample mode: 40 ul Sample Description ‘Whole blood with recommended anticoagulant. Siemens approved Quality Control Analysis Time Time to result: 50 seconds nominal. External Interfaces Two RS 232 ports are availabe, Data Management Protocols US 1, Li52,LIS3 Dimensions Width 386mm Depth 380mm Height 371mm Weight 13.1 kg Entered Parameters Range Unit Temperature 1000-439 c For 150-1000 % att 20-250 idl. 20-250 ott 12-155 mmol/L Patient ID 12 numeric characters OperatoriD 12 numeric characters Environmental Requirements Temperature 15-32°C Humidity max. 85% at 32°C non condensing Power Rating 80VA_ Frequency 50/60Hz Voltage 100V (85-110V), 1 20V (102-132¥), 20v (187-2420, 240V (204-264V) ‘Approvals UL C-UL,IEC-601, MHW Uapant. ‘Complies with the EMC directive (CE). Developed and manufactured by ‘8S EN 1S09001 and EN46001 approved facility Specictons subject to change without por notice. Maintenance free Readysensor™ technology RAPIDLab® 348 Specifications Measured Parameters Temperature Corrected Parameters Range Unit Range Unit pH 6.001-8.000 pH pHIT) 6.001-8.000 PH H 10.0-997.7 nmol/L oO) 10.0-997.7 nmol/L PCO, -5.0-280.0, mmHg COT) -5.0-2500 mmHg 067-3333 kPa 067-3333 kPa pO, 00-7490 mmlg 0,7) 0.0-743.0 mg 000-9986 kPa 0.00-99.86 kPa Nat 80-200 mmoL/t pOJA-a}(T) 0.0-749.0 mmHg Ke 0.80:9.99 mmol/L 0.00-99.86 kPa ca 0.20-5.00 mmol/L PO,a/Al(T) 0.00-1.00 cr 40-160, mmol/L pOYFO, 0005.00 Het 12.75 % NB: elther Ca“ or Cican beconfigured, not both Selectable Calculated Parameters Acid-base ‘Oxygenation Range Unit Unit Hco;act 00-600 mmol/L o,sat 6 HCCystd 00-600 © mmol/L oct 00-4090 mLdL Belecf) 4299 mmol/L. pOj(A-a) 00-7490 mmHg BE) 2299 mmol/L 000-9986 kPa etc, 00-600 mmol pO,a/A) 0.0.1.0 Ce(74) 0,205.00 mmol/L BOYFO, 0.00500 AnionGap +600 mmol/L ctHblest) ——-2.0-25.0 oral. 20-250 git 12455 mmol/L User-friendly aspiration mode for convenient sampling Simplicity is a part of its design The RAPIDLab* 348 Analyzers speed and accuracy enable clinical staff to make critical decisions ina timely manner. ‘After all, the RAPIDLab* 348 features Compact design - meets testing needs, fits on the benchtop and calibrating gases are on-boatd. Reliabi ‘Tried, tested and proven by satisfied users in hospitals around the world, every day. Sampling process maximizes sample precision and sample economy - automatically recognizes the sampling device and adjusts for the appropriate volume No maintenance, less hands-on - RAPIDLab* 348 uses patented Readysensor™ technology that requires no maintenance, saving valuable labour time and maximizing uptime of the system. Greater connect integrates with Rapialink™ Critical Care Information and Systems Management to help you manage patient, QC and systems data. Onboard information management - helps manage patient, QC and system information Ina clear and concise maner. It has a storage of, statistical values for 30 sets of QC data for multiple levels. Accuracy and precision you can rely on - Comprehensive quality control materials and procedures help you verify the performance of your system.

You might also like