Professional Documents
Culture Documents
GRÄF&MEYER
Fon +49 (0) 6841 / 934 93-0 Fax +49 (0) 6841 / 934 93-10
info@gplusm.de www.gplusm.de
&
GRÄF&MEYER
Connection Options
Each GREEMATRIX (GM BU) can control the following Up to 15 monitored GM TER, GM SYS1 and GM SYS FT
modules or systems:
System Microphones as well as GM LIPAN.
Up to 2 GREEMATRIX EPROM Boards (GM EB) with up to Any number of unmonitored GM SYS 8, GM SYS 80 or GM
8 EPROMs each to store and control alarm and alert voice SYS LT System Microphones (depending on power supply).
announcements or other audio signals for different zones.
Further Accessories
Up to 2 GREEMATRIX Input Boards (GM IB) to feed in up to
2x2 external signal sources. Gräf & Meyer LINEGUARD or EVALINE range loudspeaker
line monitoring systems.
Up to 4 GREEMATRIX Output Boards (GM OB) to activate
up to 4x2 master outputs. Gräf & Meyer SINUS range amplifiers.
1 GREEMATRIX I/O Board (GM I/O) to connect all Gräf & Meyer EVA24 range emergency power supplies.
monitored and unmonitored system microphones.
Modem (MOD) for remote configuration and maintenance.
Up to 10 GREEMATRIX Relay Boards (GM REL) with 8
MCPs (manual call panel) to initiate emergency announce-
relays each to control functions not related to safety.
ments.
1 GREEMATRIX Switch (GM SW) emergency switchover
Telephone Interface (TELA) to feed in telephone
system to control up to 12 amplifiers.
announcements through the electro-acoustic control
1 GREEMATRIX Emergency Panel (GM LIPAN) to initiate centre.
different announcements (alarm/alert ) from the
GREEMATRIX Basic Unit (GM BU) into different zones. Information on additional Gräf & Meyer accessories such
as 19“ racks including accessories, control and monitor
Up to 4 GREEMATRIX Audio Panels (GM AUPAN) for panels, voice memory, customer information systems,
external selection and volume control of music feeds. piped music systems, etc. can be obtained from the main
catalogue.
GM IB - GREEMATRIX Input-Board
in accordance with DIN EN 60849 (VDE 0828)
The GREEMATRIX Input Board (GM IB) feeds 2 external signal sources into the
GREEMATRIX Basic Unit (GM BU).
Every input is transformer balanced and has separate tone control (bass and treble).
GM OB - GREEMATRIX Output-Board
in accordance with DIN EN 60849 (VDE 0828)
The GREEMATRIX Output Board (GM OB) is able to feed two master output signals from
the GREEMATRIX Basic Unit (GM BU).
GM EB - GREEMATRIX EPROM-Board
in accordance with DIN EN 60849 (VDE 0828)
Each GM EB has 8 pieces 24-pin-socket supporting the (non volatile) 4MB EPROMs.
All the functions of the GM ES are monitored by the GREEMATRIX Basic Unit (GM BU)
When using two GM EB, the alarm- and alert messages can be transmitted symulatingly
into different zones.
The microphone capsule is monitored in accordance with DIN EN 60849 (VDE 0828).
The configuration of EVA 16 TER includes keys which are protected against accidental
misuse for safety-relevant system functions and a built-in, high-quality, two-line display to
allow checking of the current operating status as well as a panic button (WECP worst case
emergency paging) which is also access protected permits to establish a direct
microphone connection to all the connected amplifier (British security standard).
The paging configuration of the call funktion can be defined on an internal DIL switch.
The microphone capsule is monitored in accordance with DIN EN 60849 (VDE 0828).
Futher features of the GM SYS 1 are, one access lowered and red colored button for
emergency call´s and a LED to display line occupation.
The microphone capsule is monitored in accordance with DIN EN 60849 (VDE 0828).
Including a built-in two-line LCD display to monitor operating status, adjustable volume
control at the System Microphone.
User specific programming: collective call, single call and group call with corresponding
priority levels.
GM SYS LT - System Microphone with collective call and emergency call function
EVOLUTION System Microphone with collective call and emergency call function to be
connected directly to the EVOLUTION Microphone BUS.
The GM SYS LT is equipped with one call button and a LED to display line occupation.
Redundant amplifier manager in accordance with DIN EN 60849 (VDE 0828), monitor up to 12 amplifiers and if required to
the switchover the outline to one of the reserve amplifiers.
User-specific routing of the amplifiers and reserve amplifiers can be realized through corresponding wiring of the
redundant amplifier.
Alarm/Alert (pre-alarm) panel to activate the EPROM stored voice message of the
GREEMATRIX Basic Unit.
Supports paging and the simultaneous diffusion of two different messages into different
zones.
All interal functions are monitored in accordance with DIN EN 60849 (VDE 0828).
Automatic triggering interface for firealarm, interface for alarm or alert into 8 zones.
Wall housing with lockable acrylic glass door to avoid unintended operation.
The GREEMATRIX audio panel (GM AUPAN) allows a remote control of the different
music channels and their volumes adjustments.
Technical Specifications
GM IB - GREEMATRIX Input-Board
Inputs 2x; 0dB; 10kOhm; transformer balanced Operating voltage internal through GM BU
Input voltage +6dB (max.) Frequency range 50Hz-20kHz
GM OB - GREEMATRIX Output-Board
Outputs 2x; 0dB; 600Ohm; transformer balanced Operating voltage internal through GM BU
Output voltage +6dB (max.) Frequency range 50Hz-20kHz
GM EB - GREEMATRIX EPROM-Board
Memory EPROM - 480 sec. (fog=8kHz) Operating voltage internal through GM BU
- 240 sec. (fog=16kHz) Frequency range 50Hz-16kHz (50Hz-8kHz)
GM SW - GREEMATRIX SWITCH
Controlled amplifiers 12 (max.) Connections Screw terminals
Switching current 5A AC (max.) Connection cable 15-pin D-SUB cable to GM BU
Switching voltage 160V AC (max.) (max. 2 m)
Housing sheet steel; black
Dimensions (WxHxD) 483x44x190mm (19”; 1U)
Weight 2.25 kg
Technical Specifications
Safety advice: Do not expose devices to splashing or dripping water and do not place containers filled with liquid on devices.
The mains plug of the mains connection line is used as a disconnection device and must be easily accessible.
The devices may only be operated connected to a mains power socket with a protective earth conductor connection.
Environmental factors: Temperature range: -5 °C>T>+55 °C; humidity: 20 %-99 % (non-condensing); air pressure: 86 kPa-106 kPa
1 2
* = depending on fire protection guidelines in E30, * = longer lengths according to installation manual
GM EB Slave GM IB Slave
GM OB Master
GM MOD
commercial area
CD u
INFO VOICE
GM OB Master
TELA G R E E M AT R I X ( M a s t e r )
ON/OFF MONITOR
1 2 3 4 Zone 3-11A/1 Zone 3-11B/1 Zone 3-11A/... Zone 3-11B/...
G R E E M AT R I X ( S l a v e ) operating premises
GM OB Slave
ON/OFF MONITOR
1 2 3 4
G R E E M AT R I X s w i t c h
G R E E M AT R I X s w i t c h GM OB Slave
Zone 2A/1 Zone 2B/1 Zone 2A/... Zone 2B/...
GM IB Master GM IB Master
LINEGUARD
Messen Stunden Minuten Reset Störung concessionaires
GM I/O GM EB Master
mall
S I N U S 41 0
GM TER GM SYS 8
OVERLOADED SIGNAL POWER
parking deck
1-10
GM MLD GM SYS 8
S I N U S 41 0 ( H a v a r i e ) OVERLOADED SIGNAL POWER
LNG REL
GM LIPAN GM SYS FT
GM REL