12 kV Oil Test Cell

CP TC12
12 kV Oil Test Cell

The CP TC12 is used in conjunction with the CPC 100 and the
CP TD1 to measure the Permittivity and Tangent Delta / Power
Factor of insulation liquids, e.g. transformer oil. The three-
electrode design with guard allows precise measurement,
especially of small losses.

The circular electrodes are constructed from rigid stainless


steel and require a sample of 1.2 to 2 liters (41 to 68 fl.oz.).

Electrical connection to the Test Cell is made using the


standard cables provided with the CP TD1.

Technical Data
Cell Type: Three-terminal, guarded
Cell Gap Spacing: 11 mm (2.31"), nominal
Sample Volume: 1.2 liters (min.) to 2 liters (max.)
(41 to 68 fl.oz.)
Cell Capacitance: 65 pF, nominal (in air)
Maximum Test Voltage: 12 kV rms
Voltage Operating Range: 2.5 to 12 kV for a stress of 200 to
1100 V/mm (7.87 to 43.31 V/inch)
Connectors: 6 mm (0.24") sockets for high
voltage cable, 4 mm (0.15") sockets
for measuring cables
Dimensions: 22 x 25 cm (8.7" x 10.2")
[diameter x height]
Weight: approx. 6 kg (13.2 lbs.)

Article Nr.: VEHZ0601

Contact
North and South America
OMICRON electronics Corp. USA
Phone: +1 713 830 4660 or 1-800-OMICRON
info@omicronusa.com

Europe, Africa, Middle East


OMICRON electronics GmbH, Austria
Phone: +43 5523 507-0
info@omicron.at

Asia, Pacific
OMICRON electronics Asia Limited, Hong Kong
Phone: +852 2634 0377
info@asia.omicron.at

www.omicronusa.com or www.omicron.at © OMICRON, V 6.3.1.1-ENU-AM


Subject to change without notice