Professional Documents
Culture Documents
CONFORMITY ASSESSMENT
FOR NON-ELECTRICAL
ATEX & IECEx PRODUCTS
A practical guide
03
Intended zone of use and
category of the equipment
The first step is to identify the intended Hazardous The table below shows the relationship between
Area zone of use for the equipment. This enables the intended location of use and necessary level of
manufacturer to determine the relevant Category of protection of equipment.
equipment, under ATEX and Equipment Protection
Level under IECEx, that is needed in this application.
I (Mines susceptible 0 1 Ma
to firedamp) 1 2 Mb
0 1 Ga
II (Gas Atmospheres) 1 2 Gb
2 3 Gc
20 1 Da
22 3 Dc
04
Conformity assessment
routes available
ATEX, like the other New Approach Directives The ultimate responsibility remains with
employs a risk based approach to conformity the manufacturer, which means it is critical
assessment. The most onerous technical that manufacturers can demonstrate that a
requirements and conformity assessment scrutiny comprehensive conformity assessment was
apply to the highest risk applications. In high and conducted.
very high risk applications, it is mandatory to seek
the involvement of a Notified Body. It is quite common that manufacturers engage the
involvement of a Notified Body, even when this
In all cases, the manufacturer must do the same is not a mandatory requirement as it allows them
thorough and high quality evaluation of compliance to demonstrate that their assessment has been
to the harmonized standards, to ensure that the independently verified by a recognized technical
equipment is safe for the intended zone of use. authority.
ATEX 2014/34/EU
Internal
Combustion Engine
or Electrical
Equipment?
YES NO
AND AND
OR OR
OR
* and their components and devices according to Article 1(1), if separately assessed. (Source: ATEX 2014/34/EU Guidelines, Ed. 1, European Commission).
05
IECEx Certified Equipment
Certificate of Conformity
issued by ExCB
(CofC)
OR
Unit Verification
06
Harmonized standards
and protective methods
To achieve conformity to the ATEX Directive the In 2016, the EN 13463 series was superseded by
Essential Health & Safety Requirements (EHSRs) must adopting ISO 80079-36 and ISO 80079-37 and
be met. In practical terms, manufacturers may follow including some requirements in the existing EN
the applicable harmonized standard(s) in order to 60079 series of standards. The table on the next
enable them to ‘presume conformity’ to the formal page shows the changes and harmonized standards
EHSRs and proceed to place the product on the available.
market. While certification directly according to the
EHSRs is possible, it is more straightforward to use In addition, for non-electrical equipment there are
harmonized standards. For IECEx the only possibility some addition standards which must be followed:
is to follow the applicable standards. • EN 1127-1 Potential Mechanical and Electrical
Ignition Sources, which need to be considered
In 2016 the harmonized standards underwent the in the Ignition Hazard Assessment, and;
most significant update since the implementation of • The relevant Industrial Standard that would be
the ATEX Directive. This update has also aligned the applicable in normal industrial applications for
approach to non-electrical equipment in both ATEX the type of equipment in question. Hazardous
and IECEx conformity assessment schemes. Area standards should therefore be viewed as
an extension of existing best practice.
Prior to 2016 the harmonized standards for non-
electrical equipment were the EN 13463 series which
identified both the General Requirements, applying
to all equipment, and the specific requirements for
Protective Measures available to protect against
ignition sources.
07
Harmonized standards Harmonized standards
prior to 2016 from 2016 onwards
EN 13463-1 General Requirements for all ISO/EN General Requirements for all
non-electrical equipment 80079-36 non-electrical equipment
Parts of IEC/
EN 60079-0
08
Conducting a high-quality Ignition the informative guidance in Annex B and worked
Hazard Assessment examples in Annex C. This standard contains an
An Ignition Hazard Assessment is central to excellent template which can be used for reporting.
compliance of non-electrical equipment.
Completing this exercise in comprehensive, Applying Protective Measures to achieve desired
structured and well documented manner will equipment category
enable you to ensure that the necessary level Following completion of the Ignition Hazard
of protection for the equipment is achieved. Assessment stages 1 and 2, it is very likely that a
number of ignition sources have been identified.
It is highly recommended that manufacturers follow In order to prevent the potential ignition sources
the method and structure of the Ignition Hazard becoming effective, you will need to apply
Assessment which is detailed in Clause 5 of ISO/ protective measures.
EN 80079-36 which should be viewed together with
1 2 3 4
ignition hazard assessment of the frequency of measures applied to prevent the ignition source frequency of occurrence
occurrence without application of becoming effective incl. measures applied
an additional measure
a B a b c d e a b c a b c d e f
technical
during rare malfunction
necessary restrictions
No.
during foreseeable
(citation of documentation
not relevant
not relevant
malfunction
malfunction
standards,
description/basic cause technical
rules, (evidence
potential (Which conditions experi- including relevant
ignition originate which ignition reasons for description of the mental features listed in
source hazard?) assessment measure applied results) column 1)
– 52 –
face temperature no. …. about
under the most the thermal
adverse conditions. A type test
temperature moni- – attestation of
drive has critical
hot hot surface of a frictional toring and limiting ISO 80079- conformity and Gc
1 X heating during X T4
surface wheel drive system (ignition 37 "b" instructions of Dc
normal operation
prevention type 1; the monitoring
type of protection system (pur-
"b1") is mounted. chased from
ISO 80079-36:2016 ISO 2016
NEK ISO 80079-36:2016 provided by Standard Online AS for DNV GL Group Companies 2017-10-23
09
Marking the Equipment for the User The marking is often displayed as a single line, but
Once the evaluation process is completed, you is reflective of two elements: the ATEX Directive
are ready to mark the equipment. The marking marking (basic information on the level of explosion
is intended to help the user of the equipment to protection) and the Standards marking (which
correctly identify the area of intended use, protection reflects the detailed parameters for the user and
concepts applied and critical specifications such as maintainer of the equipment.)
surface temperature and gas or dust groups with
which it is intended to be used.
2460 II 2 G
Complies with Notified Specific Marking for Equipment Equipment Environment
the European Body Explosion Protection Group Category
Directive Number
Standards marking
Ex h IIC T4 Gb
Explosion Type of Gas group Temperature Class Equipment
protection protection (T1-T6) Protection Level
Ex tb IIIC T135°C Db
Explosion Type of protection Dust type Temperature Class (°C) Equipment
protection Protection Level
10
Documenting Compliance ■■ A list of all standards applied.
- Technical Construction File (TCF)
The Technical Construction File is the critical ■■ Assessment of the equipment for conformity: including
document to record the compliance evidence of the test data, if any, ignition hazard assessment etc.
equipment before it is dispatched. The manufacturer
must ensure that the TCF is stored and available • Ignition Hazard Assessment Document,
for retrieval for a period of 10 years after the last recommended to be presented in table format
production date for the equipment it refers to. This is identified in ISO EN 80079-36 Clause 5 and
a legal requirement under ATEX for products placed Annex B.
on the European market.
• Clause by Clause assessment of all applied
Depending on the category of risk, you may need standards is the most effective way to demonstrate
to store the TCF with a Notified Body or at the conformity, for example see below.
manufacturer’s own facility, though care should be
taken as the requirements for ability to trace and • Test Reports should identify test method, test
retrieve the file are the same. At DNV GL we offer equipment including calibration data and test results.
TCF storage also for non-mandatory Notified Body
storage as our physical and digital archives which ■■ The equipment marking according to Annex II clause
may be interest to small-medium enterprise without 1.05 of the ATEX directive and the requirements of the
an archive integrity solution of their own. standards (EN/ISO 80079-36 Clause 11).
Checklist for Contents of the Technical ■■ Instructions for use, in accordance with EN/ISO 80079-36
Construction File (TCF) Clause 10 & ATEX Directive Annex II, Clause 1.06.
The TCF must contain the following mandatory
minimum content defined by the directive, listed Note: While this guide focuses on Hazardous Area
below: Equipment compliance, be aware that for CE
marking other directives may also apply, such as
■■ A general description of the equipment/product. Machinery Directive, which may have additional
requirements to supplement this list.
■■ Manufacturing drawings that describe the design of the
equipment and the protection type, if any used.
11
Submitting the Technical
Construction File (TCF) to a
Notified Body
DNV GL provides a number of standard services for
conformity assessment of non-electrical equipment,
detailed below:
12
13
SAFER, SMARTER, GREENER
DNV GL
DNV GL is a global quality assurance and risk management company. Driven by our purpose of
safeguarding life, property and the environment, we enable our customers to advance the safety and
sustainability of their business. With origins stretching back to 1864 and operations in more than 100
countries, our experts are dedicated to helping customers make the world safer, smarter and greener.
As one of the world’s leading certification bodies, we help businesses assure the performance of
their organizations, products, people, facilities and supply chains through certification, verification,
assessment and training services. Partnering with our customers, we build sustainable business
performance and create stakeholder trust across all types of industries.
© DNV GL AS. 2018. All rights reserved. Images from Shutterstock and iStock, unless specified.