Professional Documents
Culture Documents
PANEL SYNC GENSET 33kVA
PANEL SYNC GENSET 33kVA
hence the reproduction, transfer and / or utilisation in whole or in part are prohibited without
its prior written consent of PT LABBERU.
Batam-Indonesia
Fax: +62 778 451497
Email : info@labberu.com
PT. LAB BERU
Komp. Bengkong Mas Blok C No. 3-5 Bengkong
NIKOI ISLAND RESORT
PANEL SYNC
INDEX
GENSET 33kVA
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
PANEL SYNC
CHANGE RECORD
GENSET 33kVA
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
PANEL SYNC
LEGEND SYMBOL
GENSET 33kVA
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
PANEL SYNC
LEGEND SYMBOL
GENSET 33kVA
OCR
EFR
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
PANEL SYNC
LEGEND SYMBOL
GENSET 33kVA
VSS
ASS
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
PANEL SYNC
LEGEND SYMBOL
GENSET 33kVA
PANEL SYNC.GENSET
L1 L2 L3 L1 L2 L3 L1 L2 L3
GENSET-1 GENSET-1 GENSET-1 PHOTO CELL PHOTO CELL PHOTO CELL GENSET-2 GENSET-2 GENSET-2
1F1 1F2 1F3 1F4 1F5 1F6 1F7 1R1 1R2 1R3 2F1 2F2 2F3 2F4 2F5 2F6 2F7 2R1 2R2 2R3
WIENTEK MT8701iE1
HMI
3F1 3F2
FUSE MCB
10A 3P+N 6A
1P/4.5kA
FRONT
GEN-SET CONTROL MODULE GEN-SET CONTROL MODULE
A L A RM/WARNING A UX .L INK
GC-500 PLUS S A L A RM/WARNING A UX .L INK
GC-500 PLUS S
Box Control
MUL TI FUNCTI O N DISPLAY MUL TI FUNCTI O N DISPLAY
E VE NTS E VE NTS
LOAD/BUS LOAD/BUS
0 1 0 1
TEST TEST
A UTO E NG I NE RUNNING E CU I NTERFA CE A UTO E NG I NE RUNNING E CU I NTERFA CE
TEST TEST
GENSET-1 PV GENSET-2
CB CLOSE CB OPEN CB TRIP DC AVAILABLE CB CLOSE CB OPEN CB TRIP CB CLOSE CB OPEN CB TRIP DC AVAILABLE
GENSET-1 GENSET-2
MODULE MANUAL OPERATION GENSET OP. MODE SELECT MASTER PV OP. MODE MANUAL OPERATION MODULE MANUAL OPERATION
OFF ON OPEN CLOSE AUTO MAN GEN-1 GEN-2 AUTO MAN OPEN CLOSE OFF ON OPEN CLOSE
Q1 Q2 Q3 QF1
EMERGENCY
STOP
EMG.3
TERMINAL
CONNECTION
BAE
12V 6A
TERMINAL
CONNECTION
BAE
12V 6A
TERMINAL
CONNECTION
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
PM
2A
QF1
MAIN BUS CU.BAR 3P4W
1x(25x5mm + PE)
2A 2A 2A
M M M
Q1 Q2 Q3
2A 2A 2A
G G
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
PANEL SYNC
SINGLE LINE DIAGRAM
GENSET 33kVA
INCOMING
GENSET-1
R S T N
GENSET VOLTAGE
SICES MODULE
LINE
CONTROL
11
OF1
21
OF2
31
OF3
81
SDE
UVT
R Y B
12 14 22 24 32 34 82 84
AUXILIARY CONTACT NS
INCOMING INDICATION
GEN-1
BUS VOLTAGE-1
SICES MODULE
IA11
IB11
IC11 CT
MODUL SICES
IS11
R S T N
MAIN BUS
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
SCHEMATIC DIAGRAM
PANEL SYNC
SENSING INCOMING
GENSET 33kVA
GEN-1
IA11 GENSET BUS
PMC BUS-G1
VOLTAGE-1 VOLTAGE-1
CT 1.2.3 IB11
SICES MODULE
GC 500Plus IC11
U1
IS11
U1
SICES
GC500p
+1VBD
JB102
JI104
-1NBD
JH101
JH102
JH203
JN101
JN103
JN104
U1
SICES
OFF ON GCB
S1 1R4 SL4
MODULE
OFF-ON
FUEL
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
SCHEMATIC DIAGRAM
PANEL SYNC
CONTROL MODULE
GENSET 33kVA
GEN-1
EMG1
101
AUTO MAN
S3
106
OPEN CLOSE
102 S2
105
U1
SICES
GCB
104
107
103
107
103
103
82
82
1R4
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
SCHEMATIC DIAGRAM
PANEL SYNC
CONTROL BREAKER
GENSET 33kVA
GEN-1
CONNECTION TO ENGINE
PANEL SYNC. GEN
G1X10
G1X11
G1X12
G1X13
G1X14
G1X15
G1X16
G1X17
G1X18
G1X19
G1X20
G1X21
G1X22
G1X23
G1X24
G1X25
G1X26
G1X27
G1X28
G1X29
G1X1
G1X2
G1X3
G1X4
G1X5
G1X6
G1X7
G1X8
G1X9
BAE-1
-1NBD 0V BATTERY G1X24
24 VDC CHARGER
TO SICES MODULE
U1 +1VBD 12V MODULE G1X25
12V/5A
4L11
220VAC
FROM MAIN BUS 4N1
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
LINE
CONTROL
11
OF1
21
OF2
31
OF3
81
SDE
UVT
R Y B
12 14 22 24 32 34 82 84
AUXILIARY CONTACT NS
INCOMING INDICATION
PV
220 VAC
TO SMARTGEN
BATTERY CHARGER
R S T N
MAIN BUS
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
SCHEMATIC DIAGRAM
PANEL SYNC
SENSING INCOMING
GENSET 33kVA
PV
PS 00 1 2 3 4
INCLUDE ON TM251MESE TM2DDI16DK TM2DDO16TK TM3AQ2 TM3AQ2
CPU
Power Source 16 16 2 2
Module DIGITAL INPUTS DIGITAL OUTPUTS ANALOG OUTPUTS ANALOG OUTPUTS
DC 24V
IO I16 QO Q16 AO A1 AO A2
24V 0V
BATTERY BATTERY
12V 12V
Page Page Page Page
003-004 009 003-004 009
220
220 VAC
FROM BUS PV
0
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
TM2DII16DK
DIGITAL INPUTS
DI101
DI102
DI103
DI104
DI105
DI106
DI107
DI108
SL3 1R4 3R4 SL5
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
TM2DII16DK
DIGITAL INPUTS
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
TM2DDO16TK
DIGITAL OUTPUTS
CH101
CH102
CH103
R1 R2 R3
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
TM2DDO16TK
DIGITAL OUTPUTS
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
TM3AQ2G
ANALOG OUTPUTS
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
201
AUTO MAN
S5
206
OPEN CLOSE
202 S6
205
204
207
203
207
203
203
82
82
208
208 209 210
2R1
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
SCHEMATIC DIAGRAM
PANEL SYNC
CONTROL BREAKER
GENSET 33kVA
PV
INCOMING
GENSET-2
R S T N
GENSET VOLTAGE
SICES MODULE
LINE
CONTROL
11
OF1
21
OF2
31
OF3
81
SDE
UVT
R Y B
12 14 22 24 32 34 82 84
AUXILIARY CONTACT NS
INCOMING INDICATION
GEN-2
BUS VOLTAGE-2
SICES MODULE
IA21
IB21
IC21 CT
MODUL SICES
IS21
R S T N
MAIN BUS
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
SCHEMATIC DIAGRAM
PANEL SYNC
SENSING INCOMING
GENSET 33kVA
GEN-2
IA21 GENSET BUS
PMC BUS-G2
VOLTAGE-2 VOLTAGE-2
CT 1.2.3 IB21
SICES MODULE
GC 500Plus IC21
U2
IS21
U2
SICES
GC500p
+2VBD
JN201
JN203
JN204
JB201
-2NBD
JH101
JH102
JH203
JI201
U2
SICES
OFF ON GCB
S7 3R4 SL4
MODULE
OFF-ON
FUEL
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
SCHEMATIC DIAGRAM
PANEL SYNC
CONTROL MODULE
GENSET 33kVA
GEN-2
EMG1
301
AUTO MAN
S4
306
OPEN CLOSE
302 S8
305
U2
SICES
GCB
304
307
303
307
303
303
82
82
311
308 309 310
3R4
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
SCHEMATIC DIAGRAM
PANEL SYNC
CONTROL BREAKER
GENSET 33kVA
GEN-2
CONNECTION TO ENGINE
PANEL SYNC.GEN
G2X10
G2X11
G2X12
G2X13
G2X14
G2X15
G2X16
G2X17
G2X18
G2X19
G2X20
G2X21
G2X22
G2X23
G2X24
G2X25
G2X26
G2X27
G2X28
G2X29
G2X1
G2X2
G2X3
G2X4
G2X5
G2X6
G2X7
G2X8
G2X9
BAE-2
-2NBD 0V BATTERY G2X24
24 VDC CHARGER
TO SICES MODULE
U2 +2VBD 12V MODULE G2X25
12V/5A
4L11
220VAC
FROM MAIN BUS 4N1
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
S S
T T
N N
MAIN BUS
IS31
IB31 IB31
IS31
IC31 IC31
IS31
IS31 IS31
OUTGOING
THE INFORMATION IN THIS DOCUMENT ARE PROPERTY OF PT LABBERU, AND IS PROHIBITED USE WITHOUT PRIOR WRITTEN CONSENT.
SCHEMATIC DIAGRAM
PANEL SYNC
SENSING INCOMING
GENSET 33kVA
GEN-2
MODULE
COMMUNICATION
GENSET-1 GENSET-2
SICES SICES
GC 500p GC 500p