Pulse Input Type/ Pulse Input Type Page 613 CC-Link Direct Input Type Page 613
Positioning Type Page 613
Absolute Type/ Absolute Type/
Incremental Type/ LECSB Series LECSC Series
LECSA Series
607 B
AC Servo Motor Driver
LECS/LECSS-T/LECY Series list
Application/ Compatible
Compatible motor Control method
Function option
Series
Note 1) Network Note 2) Setup
100 W 200 W 400 W Positioning Pulse Synchronous
direct input software
Incremental Type
Up to
7 points LEC-MRC2
LECSA
(Pulse input type/
Positioning type)
LEC-MRC2
LECSB
(Pulse input type)
Up to CC-Link
255 points Ver. 1.10 LEC-MRC2
LECSC
(CC-Link direct input type)
LECSS
Absolute Type
(SSCNET 3 type)
Compatible with Mitsubishi Electric’s
servo system controller network
LECSS-T
(SSCNET 3/H type)
Compatible with Mitsubishi Electric’s
servo system controller network
-@
MECHATRO
LINK-2 Note 3) SigmaWin+™
LECYM
-#
MECHATRO
LINK-3 Note 3) SigmaWin+™
LECYU
Note 1) For positioning type, setting needs to be changed to use with maximum set values.
Setup software (MR Configurator2™) LEC-MRC2 is required.
Note 2) Available when the Mitsubishi motion controller is used for the master equipment.
Note 3) Available when the motion controller is used for the master equipment.
∗ For customer-provided PLC and motion controller setting and usage instructions, confirm with the retailer or manufacturer.
A 608
LECS/LECSS-T/LECY Series
Speed
Speed
• Control the difference between time Settling
command value and actual action time
Time Time
609 B
AC Servo Motor Driver
Display Display
Display the communication Display the communication
status with the driver, the status with the driver and
alarm and the point table No. the alarm.
Settings
Settings
Switches for selecting
Control Baud rate, station axis and switching to
number and the occupied (With the front cover opened) (With the front cover opened)
the test operation
station count. LECSC LECSS
Display
Display the communication
status with the driver and
the alarm.
Settings
Switches for axis setting,
control axis deactivation,
switching to test operation, LECSS2-T
and other operations
Settings Settings
Switches for station address, Switches for station address,
communication speed, number of transmission bytes,
number of transmission bytes, and other operations
and other operations
Display Display
Driver status and alarm Driver status and
display alarm display
LECYM LECYU
A 609-1
System Construction
Incremental encoder compatible LECSA Series Provided by customer
Option
(Pulse input type/Positioning type)
Control circuit
Main circuit Page 617 power supply Setup software Page 626
Provided by customer power supply Driver 24 VDC
connector (MR Configurator2™)
Power supply (Accessory) Part no.: LEC-MRC2
Single phase 100 to 120 VAC (50/60 Hz)
200 to 230 VAC (50/60 Hz)
Absolute encoder compatible LECSB Series USB cable Page 626-1 Option
(Pulse input type) Driver Part no.: LEC-MR-J3USB
Provided by customer Main circuit Page 618
power supply Setup software Page 626
Power supply connector (MR Configurator2™)
Single phase 100 to 120 VAC (50/60 Hz) (Accessory)
Part no.: LEC-MRC2
200 to 230 VAC (50/60 Hz)
Three phase 200 to 230 VAC (50/60 Hz)
Analog
Option Page 625 monitor
Regeneration option output
Part no.: LEC-MR-RB- RS-422 PC
communication
Motor cable Page 623
Standard cable Robotic cable
LE-CSM-S LE-CSM-R
Control
Lock cable Page 623 circuit power supply Page 618
Standard cable Robotic cable connector
LE-CSB-S LE-CSB-R (Accessory)
Option Page 623
Electric actuator I/O connector
Slider type Rod type Motor Page 618 Part no.: LE-CSNB
LEF Series LEY Series connector or
(Accessory) I/O cable Page 624
Part no.: LEC-CSNB-1 Provided by
High rigidity slider type Guide rod type
LEJ Series LEYG Series customer
PLC (Positioning unit)
Power supply
Encoder cable Page 623 Page 626-1
for I/O signal
Standard cable Robotic cable Battery (Accessory) 24 VDC
LE-CSE-S LE-CSE-R Part no.: (LEC-MR-J3BAT)
610 A
System Construction
Absolute encoder compatible LECSC Series Driver
(CC-Link direct input type)
Provided by customer Main circuit Page 618 USB cable Page 626-1 Option
power supply Part no.: LEC-MR-J3USB
Power supply connector
Single phase 100 to 120 VAC (50/60 Hz) (Accessory) Setup software Page 626
200 to 230 VAC (50/60 Hz) (MR Configurator2™)
Three phase 200 to 230 VAC (50/60 Hz) Part no.: LEC-MRC2
PC
Motor cable Page 623
Standard cable Robotic cable CC-Link connector Note)
LE-CSM-S LE-CSM-R
Control circuit Page 618 (Accessory)
power supply connector
Lock cable Page 623 (Accessory)
Standard cable Robotic cable
LE-CSB-S LE-CSB-R
Option Page 623
Electric actuator Motor Page 618 I/O connector
Slider type Rod type connector Part no.: LE-CSNA
LEF Series LEY Series (Accessory) or
I/O cable Page 624
Part no.: LEC-CSNA-1
High rigidity slider type Guide rod type Provided by
LEJ Series LEYG Series customer
Page 626-1
Battery (Accessory) PLC (CC-Link master unit)
Part no.: (LEC-MR-J3BAT)
Power supply
for I/O signal
Encoder cable Page 623 24 VDC
Standard cable Robotic cable
LE-CSE-S LE-CSE-R Note) Product number: K05A50230600 manufactured by Mitsubishi Electric System & Service Co., Ltd.
A 611
System Construction
Absolute encoder compatible LECSS Series Option
(SSCNET # type)
Setup software Page 626
Driver (MR Configurator2TM)
Provided by customer Page 618 USB cable Page 626-1 Part no.: LEC-MRC2
Main circuit Part no.: LEC-MR-J3USB
Power supply power supply
Single phase 100 to 120 VAC (50/60 Hz) connector
200 to 230 VAC (50/60 Hz) (Accessory)
PC
Three phase 200 to 230 VAC (50/60 Hz)
Page 618
Electric actuator CN1B
Motor connector CN1A
Slider type High rigidity slider type
(Accessory)
LEF Series LEJ Series Option Page 624
Rod type SSCNET # Provided
LEY Series optical cable by
Guide rod type
Part no.: LE-CSS- customer
LEYG Series
Page 626-1
PLC (Positioning unit/
Motion controller)
Battery (Accessory)
Encoder cable Page 623
Standard cable Robotic cable
Part no.: (LEC-MR-J3BAT) Power supply for I/O signal
LE-CSE-S LE-CSE-R 24 VDC
CN1A
Electric actuator
Slider type High rigidity slider type Rod type Guide rod type
LEF Series LEJ Series LEY Series LEYG Series Provided by customer
PLC (Positioning unit/Motion controller)
Power supply
for I/O signal
24 VDC
∗ The LECSS2-T cannot be used with the LEC-MR-SETUP221.
611-1 A
System Construction
Absolute encoder compatible LECYM Series
Driver
-@ type
B3
V
Standard cable Robotic cable
Option
Setup software Page 628-10
LE-CYB-S- LE-CYB-R- W
(SigmaWin+TM)
I/O Page 628-8 Please download it via our website.
Electric actuator Motor Page 628-4 connector
connector Part no.: LE-CYNA
Slider type High rigidity slider type
LEF Series LEJ Series (Accessory) or
Rod type
I/O cable Page 628-8
LEY/LEYG Series Part no.: LEC-CSNA-1
PC
∗ Order USB cable (Part no.: LEC-
Encoder cable Page 628-7 Cable for safety function JZ-CVUSB) separately to use this
Standard cable Robotic cable device (3 m) Page 628-10 software.
LE-CYE-S LE-CYE-R Part no.: LEC-JZ-CVSAF
B3
A 611-2
AC Servo Motor Driver Power supply voltage
100 to 120 VAC
200 to 230 VAC
,
Compatible with Mitsubishi Electric s servo system controller network
Reduced wiring and SSCNET # optical cable for one-touch connection
SSCNET # optical cable provides enhanced noise resistance
Up to 16 drivers connectable with SSCNET # communication
Applicable Fieldbus protocol: SSCNET #
(High-speed optical communication, Max. bidirectional communication speed: 50 Mbps)
Control encoder: Absolute 18-bit encoder (Resolution: 262,144 pulse/rev)
612 A
AC Servo Motor Driver Power supply voltage 200 to 230 VAC
3 times
LECSS-S Series faster
Optical
Bidirectional communication
communication speed
(Mbps)
50 100 150
A 612-1
AC Servo Motor Driver Power supply voltage 200 to 230 VAC
Compliant with the SEMI F47 Standard (Torque limit for low DC power supply
¡
voltage for main circuit)
612-2 A
AC Servo Motor Driver
Incremental Type
Compatible actuators
LECSA Series (Pulse Input Type/Positioning Type)
LEF LEJ LEY Absolute Type LECSA LECSB LECSC LECSS LECSS-T
LECSB (Pulse Input Type) /LECSC (CC-Link Direct Input Type)
LECSS (SSCNET # Type) /LECSS-T (SSCNET #/H Type) Series
LECSA/LECSB/LECSC/LECSS
LECSS-T
B 613
AC Servo Motor Driver LECS/LECSS-T Series
Dimensions
LECSA
For LECSA-S1,S3 For LECSA-S4
2 x ø6 Mounting hole 2 x ø6 Mounting hole 50 135
40
(Bearing surface thickness 5) (Bearing surface thickness 5)
CNP1 CNP1
CNP2 Connector
CNP2 Description
name
130
120
130
120
5.5 6
LECSB
40
ø6 Mounting hole 135 (For LECSB-S5, S7)
6 170 (For LECSB-S8)
(Bearing surface thickness 4)
6
CN5
CN6
CNP1
Connector
CN3 Description
name
168
CN1
CN3 RS-422 communication connector
CNP3
CN4 Battery connector
CN2 CN5 USB communication connector
CN6 Analog monitor connector
CN4
CNP1 Main circuit power supply connector
CNP2 Control circuit power supply connector
6
Battery∗
(14)
∗ Battery included.
613-1 A
LECS /LECSS-T Series
Dimensions
LECSC 6
40
135 (For LECSC-S5, S7)
170 (For LECSC-S8)
2 x ø6
(Bearing surface thickness 4)
CN5
CNP1
CN3 Connector name Description
CN1 CC-Link connector
CNP2 CN1 CN2 Encoder connector
CN3
156
168
CNP3 CN4 Battery connector
CN6
CN5 USB communication connector
CN6 I/O signal connector
CN2 CNP1 Main circuit power supply connector
CN4
CNP2 Control circuit power supply connector
CNP3 Servo motor power connector
Battery∗
6
6
* Battery included.
LECSS 6
40
135 (For LECSS-S5, S7)
170 (For LECSS-S8)
2 x ø6
(Bearing surface thickness 4)
168
CNP3
CN3 I/O signal connector
CN1B
CN4 Battery connector
CN2 CN5 USB communication connector
CNP1 Main circuit power supply connector
CN4 CNP2 Control circuit power supply connector
CNP3 Servo motor power connector
Battery∗
6
6
* Battery included.
LECSS2-T
W L 2 x ø6 M
Bearing surface thickness (D)
6
156
(6)
Dimensions [mm]
Model W L D M
LECSS2-T5
135 4
LECSS2-T7 40 6
* Battery included. D LECSS2-T8 170 5
A 614
AC Servo Motor Driver LECS /LECSS-T Series
Specifications
LECSA Series
Model LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4
Compatible motor capacity [W] 100 200 100 200 400
Incremental 17-bit encoder
Compatible encoder
(Resolution: 131,072 p/rev)
Main Power voltage [V] Single phase 100 to 120 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz)
power Allowable voltage fluctuation [V] Single phase 85 to 132 VAC Single phase 170 to 253 VAC
supply Rated current [A] 3.0 5.0 1.5 2.4 4.5
Control Control power supply voltage [V] 24 VDC
power Allowable voltage fluctuation [V] 21.6 to 26.4 VDC
supply Rated current [A] 0.5
Parallel input 6 inputs
Parallel output 4 outputs
Max. input pulse frequency [pps] 1 M (for differential receiver), 200 k (for open collector)*2
In-position range setting [pulse] 0 to ±65535 (Command pulse unit)
Error excessive ±3 rotations
Function
Torque limit Parameter setting
Communication USB communication
Operating temperature range [°C] 0 to 55 (No freezing)
Operating humidity range [%RH] 90 or less (No condensation)
Storage temperature range [°C] –20 to 65 (No freezing)
Storage humidity range [%RH] 90 or less (No condensation)
Insulation resistance [MΩ] Between the housing and SG: 10 (500 VDC)
Weight [g] 600 700
LECSB Series
Model LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8
Compatible motor capacity [W] 100 200 100 200 400
Absolute 18-bit encoder
Compatible encoder
(Resolution: 262,144 p/rev)
Three phase 200 to 230 VAC (50/60 Hz)
Power voltage [V] Single phase 100 to 120 VAC (50/60 Hz)
Main Single phase 200 to 230 VAC (50/60 Hz)
power Three phase 170 to 253 VAC
supply Allowable voltage fluctuation [V] Single phase 85 to 132 VAC
Single phase 170 to 253 VAC
Rated current [A] 3.0 5.0 0.9 1.5 2.6
Control Control power supply voltage [V] Single phase 100 to 120 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz)
power Allowable voltage fluctuation [V] Single phase 85 to 132 VAC Single phase 170 to 253 VAC
supply Rated current [A] 0.4 0.2
Parallel input 10 inputs
Parallel output 6 outputs
Max. input pulse frequency [pps] 1 M (for differential receiver), 200 k (for open collector)*2
In-position range setting [pulse] 0 to ±10000 (Command pulse unit)
Error excessive ±3 rotations
Function
Torque limit Parameter setting or external analog input setting (0 to 10 VDC)
Communication USB communication, RS422 communication*1
Operating temperature range [°C] 0 to 55 (No freezing)
Operating humidity range [%RH] 90 or less (No condensation)
Storage temperature range [°C] –20 to 65 (No freezing)
Storage humidity range [%RH] 90 or less (No condensation)
Insulation resistance [MΩ] Between the housing and SG: 10 (500 VDC)
Weight [g] 800 1000
*1 USB communication and RS422 communication cannot be performed at the same time.
*2 If the command pulse train input is open collector method, it supports only to the sink (NPN) type interface. It does not correspond to the source (PNP)
type interface.
615 A
LECS /LECSS-T Series
Specifications
LECSC Series
Model LECSC1-S5 LECSC1-S7 LECSC2-S5 LECSC2-S7 LECSC2-S8
Compatible motor capacity [W] 100 200 100 200 400
Absolute 18-bit encoder
Compatible encoder
(Resolution: 262,144 p/rev)
Single phase 100 to 120 VAC Three phase 200 to 230 VAC (50/60 Hz)
Power voltage [V]
Main (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz)
power Three phase 170 to 253 VAC
supply Allowable voltage fluctuation [V] Single phase 85 to 132 VAC
Single phase 170 to 253 VAC
Rated current [A] 3.0 5.0 0.9 1.5 2.6
Single phase 100 to 120 VAC Single phase 200 to 230 VAC
Control Control power supply voltage [V]
(50/60 Hz) (50/60 Hz)
power
supply Allowable voltage fluctuation [V] Single phase 85 to 132 VAC Single phase 170 to 253 VAC
Rated current [A] 0.4 0.2
Applicable Fieldbus protocol (Version) CC-Link communication (Ver. 1.10)
Connection cable CC-Link Ver. 1.10 compliant cable (Shielded 3-core twisted pair cable)*1
Remote station number 1 to 64
Communication speed [bps] 16 k 625 k 2.5 M 5M 10 M
Cable
Communication Maximum overall cable length [m] 1200 900 400 160 100
length
specifications Cable length between stations [m] 0.2 or more
I/O occupation area 1 station occupied (Remote I/O 32 points/32 points)/(Remote register 4 words/4 words)
(Inputs/Outputs) 2 stations occupied (Remote I/O 64 points/64 points)/(Remote register 8 words/8 words)
Up to 42 (when 1 station is occupied by 1 driver), Up to 32 (when 2 stations are occupied by
Number of connectable drivers
1 driver), when there are only remote device stations.
Remote register input Available with CC-Link communication (2 stations occupied)
Available with CC-Link communication, RS422 communication
CC-Link communication (1 station occupied): 31 points
Point table No. input
Command CC-Link communication (2 stations occupied): 255 points
method RS422 communication: 255 points
Available with CC-Link communication
Indexer positioning input CC-Link communication (1 station occupied): 31 points
CC-Link communication (2 stations occupied): 255 points
Communication function USB communication, RS-422 communication*2
Operating temperature range [°C] 0 to 55 (No freezing)
Operating humidity range [%RH] 90 or less (No condensation)
Storage temperature range [°C] –20 to 65 (No freezing)
Storage humidity range [%RH] 90 or less (No condensation)
Insulation resistance [MΩ] Between the housing and SG: 10 (500 VDC)
Weight [g] 800 1000
*1 If the system comprises of both CC-Link Ver. 1.00 and Ver. 1.10 compliant cables, Ver. 1.00 specifications are applied to the overall cable length and the cable length between stations.
*2 USB communication and RS422 communication cannot be performed at the same time.
LECSS Series
Model LECSS1-S5 LECSS1-S7 LECSS2-S5 LECSS2-S7 LECSS2-S8
Compatible motor capacity [W] 100 200 100 200 400
Absolute 18-bit encoder
Compatible encoder
(Resolution: 262,144 p/rev)
Single phase 100 to 120 VAC Three phase 200 to 230 VAC (50/60 Hz)
Power voltage [V]
Main (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz)
power Three phase 170 to 253 VAC
supply Allowable voltage fluctuation [V] Single phase 85 to 132 VAC
Single phase 170 to 253 VAC
Rated current [A] 3.0 5.0 0.9 1.5 2.6
Single phase 100 to 120 VAC Single phase 200 to 230 VAC
Control Control power supply voltage [V]
(50/60 Hz) (50/60 Hz)
power
supply Allowable voltage fluctuation [V] Single phase 85 to 132 VAC Single phase 170 to 253 VAC
Rated current [A] 0.4 0.2
Applicable Fieldbus protocol SSCNET # (High-speed optical communication)
Communication function USB communication
Operating temperature range [°C] 0 to 55 (No freezing)
Operating humidity range [%RH] 90 or less (No condensation)
Storage temperature range [°C] –20 to 65 (No freezing)
Storage humidity range [%RH] 90 or less (No condensation)
Insulation resistance [MΩ] Between the housing and SG: 10 (500 VDC)
Weight [g] 800 1000
A 616
AC Servo Motor Driver LECS /LECSS-T Series
Specifications
LECSS-T Series
Model LECSS2-T5 LECSS2-T7 LECSS2-T8
Compatible motor capacity [W] 100 200 400
Absolute 22-bit encoder
Compatible encoder
(Resolution: 4,194,304 p/rev)
Main Power voltage [V] Three phase 200 to 240 VAC (50/60 Hz), Single phase 200 to 240 VAC (50/60 Hz)
power Allowable voltage fluctuation [V] Three phase 170 to 264 VAC (50/60 Hz), Single phase 170 to 264 VAC (50/60 Hz)
supply Rated current [A] 0.9 1.5 2.6
Control Control power supply voltage [V] Single phase 200 to 240 VAC (50/60 Hz)
power Allowable voltage fluctuation [V] Single phase 170 to 264 VAC
supply Rated current [A] 0.2
Applicable Fieldbus protocol SSCNET #/H (High-speed optical communication)
Communication function USB communication
Operating temperature range [°C] 0 to 55 (No freezing)
Operating humidity range [%RH] 90 or less (No condensation)
Storage temperature range [°C] −20 to 65 (No freezing)
Storage humidity range [%RH] 90 or less (No condensation)
Insulation resistance [MW] Between the housing and SG: 10 (500 VDC)
Weight [g] 800 1000
616-1 A
LECS /LECSS-T Series
CNP2
Circuit protector
Control circuit power supply +24V CN2 Encoder
24 VDC 0V
A 617
AC Servo Motor Driver LECS /LECSS-T Series
LECSS2-
For single phase 200 VAC For three phase 200 VAC
CNP1 CNP1
NFB MC NFB MC
Single L1 CNP3 Three L1 CNP3
phase phase
L2 U U L2 U U
200 to 230 Motor 200 to 230 Motor
VAC L3 V V VAC L3 V V
M M
N W W N(–) W W
P1 P1
P2 PE P2 PE
CNP2 CNP2
P P(+)
Regeneration option Regeneration option
C C
D D
CN2 Encoder CN2 Encoder
L11 L11
L21 L21
Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and L2 terminals, with nothing connected to L3.
Note) For single phase 200 to 240 VAC, power supply should be connected to L1 and L3 terminals, with nothing connected to L2.
Please note that the wiring locations differ from the LECS.
A 618-1
AC Servo Motor Driver LECS /LECSS-T Series
S/S
24V LECSA
0V Note 4) Note 4)
COM1
Y010 NP 25 Note 6)
10 m or less
COM3
15 LA A-phase pulse encoder
Y004 CR 5 16 LAR (Differential line driver)
COM2 17 LB B-phase pulse encoder
18 LBR (Differential line driver)
X INP 10 19 LZ Z-phase pulse encoder
20 LZR (Differential line driver)
X RD 11 14 LG Control common
X OP 21 Plate SD
LG 14
SD Plate
Note 4)
CN1
Forced stop EM1 8
Servo ON SON 4
Reset RES 3
10 m or less
CNP1
Note 1)
PE
,
Note 1) For preventing electric shock, be sure to connect the driver main circuit power supply connector (CNP1) s protective earth (PE) terminal (marked
,
) to the control panel s protective earth (PE).
Note 2) For interface use, supply 24 VDC ±10% 200 mA using an external source. 200 mA is the value when all I/O command signals are used and
reducing the number of inputs/outputs can decrease current capacity. Refer to “Operation Manual” for required current for interface.
Note 3) The failure (ALM) is ON during normal conditions. When it is OFF (alarm occurs), stop the PLC signal using the sequence program.
Note 4) The same name signals are connected inside the driver.
Note 5) For command pulse input with an open collector method. When a positioning unit loaded with a differential line driver method is used, it is 10 m or less.
Note 6) If the command pulse train input is open collector method, it supports only to the sink (NPN) type interface. It does not correspond to the source
(PNP) type interface.
619 A
LECS /LECSS-T Series
This wiring example shows connection with a positioning unit (QD75D) manufactured by Mitsubishi Electric Corporation as when used in
position control mode. Refer to the LECSB series Operation Manual and any technical literature or operation manuals for your PLC and
positioning unit before connecting to another PLC or positioning unit.
LECSB
Positioning unit 24 VDC Note 2) Note 4)
QD75D (Manufactured by CN1
Mitsubishi Electric Corporation) Note 4)
CN1 21 DICOM
Failure Note 3)
DICOM 20 48 ALM RA1
CLEARCOM 14 DOCOM 46 Zero speed detection
CLEAR 13 CR 41 23 ZSP RA2
Torque limiting
RDYCOM 12 25 TLC RA3
READY 11 RD 49 Positioning completion
PULSE F+ 15 PP 10 Note 6) 24 INP RA4
PULSE F– 16 PG 11
10 m or less
PULSE R+ 17 NP 35 Note 6)
S/S R–
PULSE 18 NG 36 4 LA A-phase pulse encoder
PG0 9 LZ 8 5 LAR (Differential line driver)
PG0 COM 10 LZR 9 6 LB B-phase pulse encoder
LG 3 7 LBR (Differential line driver)
SD Plate Control common
10 m or less Note 5) 34 LG Control common
33 OP Z-phase pulse encoder
1 P15R (Open collector)
Plate SD
10 m or less 2 m or less
Note 4)
CN1
Emergency stop EMG 42
Servo ON SON 15 Note 4)
Reset RES 19 CN6
Proportion control PC 17 3 MO1 Analog monitor 1
±10 VDC
External torque limit selection TL 18 1 LG
±10 VDC Analog monitor 2
Forward rotation stroke end LSP 43 2 MO2
Reverse rotation stroke end LSN 44 2 m or less
DOCOM 47
Upper limit setting
P15R 1
Analog torque limit
TLA 27
+10 V/Maximum torque
LG 28
SD Plate
2 m or less
Note 1)
PE
, ,
Note 1) For preventing electric shock, be sure to connect the driver s protective earth (PE) terminal (marked ) to the control panel s protective earth (PE).
Note 2) For interface use, supply 24 VDC ±10% 300 mA using an external source.
Note 3) The failure (ALM) is ON during normal conditions. When it is OFF (alarm occurs), stop the PLC signal using the sequence program.
Note 4) The same name signals are connected inside the driver.
Note 5) For command pulse input with a differential line driver method. For open collector method, it is 2 m or less.
Note 6) If the command pulse train input is open collector method, it supports only to the sink (NPN) type interface. It does not correspond to the source
(PNP) type interface.
A 620
AC Servo Motor Driver LECS /LECSS-T Series
LECSC
Note 2)
CN6
24 VDC +
Power CN6 14 RD RA1 Ready
supply −
DICOM 5 15 ALM RA2 Failure Note 3)
DOCOM 17
Forced stop EMG 1 16 ZP RA3 Return to origin completion
Proximity dog DOG 2
10 m or less
Forward rotation stroke end LSP 3
Reverse rotation stroke end LSN 4 13 LZ Z-phase pulse encoder
26 LZR (Differential line driver)
10 m or less
11 LA A-phase pulse encoder
24 LAR (Differential line driver)
12 LB B-phase pulse encoder
25 LBR (Differential line driver)
23 LG Control common
Plate SD
Note 1)
PE
CN1
CC-Link
, ,
Note 1) For preventing electric shock, be sure to connect the driver s protective earth (PE) terminal (marked ) to the control panel s protective earth (PE).
Note 2) For interface use, supply 24 VDC ±10% 150 mA using an external source.
Note 3) The failure (ALM) is ON during normal conditions. When it is OFF (alarm occurs), stop the PLC signal using the sequence program.
621 A
LECS /LECSS-T Series
2 m or less
CN1B SW1
SW2 Note 7)
12
Note 1)
PE
LECSS Note 6)
CN1A (Axis 2)
SW1
12
SSCNET # optical cable Note 5)
(Option) LECSS Note 6)
CN1A (Axis 3)
SW1
A 622
AC Servo Motor Driver LECS /LECSS-T Series
CN8 5 DICOM
2 m or less
CN1B SW1
SW2 Note 7)
1234
Note 1)
PE
LECSS2-T Note 6)
CN1A (Axis 2)
SW1
1234
SSCNET # optical cable Note 5) Note 1) For preventing electric shock, be sure to connect the
,
(Option) LECSS2-T Note 6) driver s protective earth (PE) terminal (marked
,
) to
CN1A (Axis 3) the control panel s protective earth (PE).
SW1 Note 2) For interface use, supply 24 VDC ±10% using an
external source.
Note 3) The failure (ALM) is ON during normal conditions.
CN1B SW2 Note 7) When it is OFF (alarm occurs), stop the master PLC
signal using the master PLC program.
Note 4) The same name signals are connected inside the driver.
1234
Note 5) Use the following SSCNET # optical cables.
Refer to “SSCNET # optical cable” on page 624 for
LECSS2-T Note 6)
cable models.
CN1A (Axis n)
SW1 Cable Cable model Cable length
SSCNET # optical cable LE-CSS- 0.15 m to 3 m
CN1B Note 6) Connections from Axis 2 onward are omitted.
SW2 Note 7)
Note 7) Up to 64 axes can be set for the axis selection rotary
Cap Note 8)
switch (SW1) and auxiliary axis number setting
1234 switches (SW2-3, SW2-4) in combination. Note that
the number of connection axes depends on the
specifications of the master PLC.
Note 8) Be sure to place a cap on unused CN1A/CN1B.
Note 9) When not using the STO function, use the driver with the
short-circuit connector (provided as an accessory) inserted.
Note 10) Configure a circuit to turn off EM2 when the main
circuit power is turned off to prevent an unexpected
restart of the driver.
622-1 A
LECS /LECSS-T Series
Options
Motor cable, Lock cable, Encoder cable (LECS, LECSS-T common)
LE CS M S 5 A
Motor type Direction of connector
S AC servo motor Axis side
Cable description
M Motor cable A
B Lock cable
E Encoder cable
LE-CSM-R2 2 180
(13.7)
LE-CSM-R5 5 400
LE-CSM-RA 10 800
(30) L Product no. øD
LE-CSB-SA Weight
4.7 Product no. Length [m] Weight [g]
LE-CSB-: Lock cable* LE-CSB-SB
LE-CSB-RA LE-CSB-S2 2 80
øD
LE-CSB-RB
LE-CSB-SA 10 400
(29.6) L LE-CSB-R2 2 80
LE-CSB-R5 5 200
LE-CSB-RA 10 400
LE-CSE-: Encoder cable
ø7.1
Weight
18.8
(13)
33.3
37.2
Options
SSCNET # optical cable (LECSS-S, LECSS2-T) I/O cable
H
Name plate + Lot. No.
LE-CSS-L
øD
0.15 100
T 100 80
LE-CSS-K 0.3 100
U W 1500
LE-CSS-J 0.5 200
LE-CSS-1 1 200 A side B side
LE-CSS-3 3 200
∗ LEC-CSNA-1: 10126-3000PE (connector)/10326-52F0-008 (shell kit)
manufactured by 3M Japan Limited or equivalent item.
LEC-CSNB-1: 10150-3000PE (connector)/10350-52F0-008 (shell kit)
manufactured by 3M Japan Limited or equivalent item.
LEC-CSNS-1: 10120-3000PE (connector)/10320-52F0-008 (shell kit)
manufactured by 3M Japan Limited or equivalent item.
∗ Conductor size: AWG24
∗ If using the LECSB, emergency stop (EMG) wiring is required in all cases.
(The electric actuator will not operate without the wiring.)
Prepare an I/O connector or an I/O cable in advance.
A side
624 B
LECS /LECSS-T Series
Options
Regeneration option (LECSl common)
LEC MR RB 12
LEC-MR-RB-032 LEC-MR-RB-12
40 ø6 Mounting hole
ø6 Mounting hole
36
(12)
30
(6)
15
(6)
15
5
144
156 5
168
144
156
168
1.6
12
6 2
6
6
12
6
(20) 99
(20) 149
119
169
Weight Weight
Model Weight [kg] Model Weight [kg]
LEC-MR-RB-032 0.5 LEC-MR-RB-12 1.1
∗ MR-RB032 manufactured by Mitsubishi ∗ MR-RB12 manufactured by Mitsubishi
Electric Corporation. Electric Corporation.
A 625
AC Servo Motor Driver LECS /LECSS-T Series
Options
USB cable
PC Setup software
(MR Configurator2™)
LECSA LECSB LECSC LECSS LECSS2-T
Drivers
Setup software (MR Configurator2™) (LECSA, LECSB, LECSC, LECSS, LECSS-T common)
LEC MRC2
* SW1DNC-MRC2- manufactured by Mitsubishi Electric Corporation.
Display language
Refer to Mitsubishi Electric Corporation’s website for operating environment and
Nil Japanese version version upgrade information.
E English version MR Configurator2™ is a registered trademark or trademark of Mitsubishi Electric
C Chinese version Corporation.
Adjustment, waveform display, diagnostics, parameter read/write, and test operation can be performed upon a PC.
Compatible PC
When using setup software (MR Configurator2™), use an IBM PC/AT compatible PC that meets the following operating conditions.
Hardware Requirements
Setup software (MR Configurator2™) Note 1) Before using a PC for setting LECSA point table method/program
Equipment operation method, upgrade to version 1.18U (Japanese version)/
LEC-MRC2 version 1.19V (English version) or later. Refer to Mitsubishi
Microsoft® Windows® 10 Edition Operating System Electric Corporation’s website for version upgrade information.
® ®
Microsoft Windows 10 Enterprise Operating System Note 2) Windows® and Windows Vista® are registered
Microsoft® Windows® 10 Pro Operating System trademarks of Microsoft Corporation in the United
® ®
Microsoft Windows 10 Home Operating System States and other countries.
Microsoft® Windows® 8.1 Enterprise Operating System Note 3) On some PCs, setup software (MR
® ®
Microsoft Windows 8.1 Pro Operating System Configurator2™) may not run properly.
Microsoft® Windows® 8.1 Operating System Note 4) The following functions cannot be used. If any of
® ®
Microsoft Windows 8 Enterprise Operating System the following functions is used, this product may
Microsoft® Windows® 8 Pro Operating System not operate normally.
® ®
Microsoft Windows 8 Operating System · Start of application in Windows® compatible mode
Microsoft® Windows® 7 Ultimate Operating System · Fast User Switching
Note 1) 2) OS ® ®
Microsoft Windows 7 Enterprise Operating System · Remote Desktop
3) 4) 5) 6) · Windows XP Mode
Microsoft® Windows® 7 Professional Operating System
7) 8) 9) 10) ® ® · Windows Touch or Touch
Microsoft Windows 7 Home Premium Operating System
PC Microsoft® Windows® 7 Starter Operating System · Modern UI
® ®
Microsoft Windows Vista Ultimate Operating System · Client Hyper-V
Microsoft® Windows Vista® Enterprise Operating System · Tablet Mode
® ®
Microsoft Windows Vista Business Operating System · Virtual desktop
Microsoft® Windows Vista® Home Premium Operating System · 64-bit OSs are not supported, except for Micro-
® ®
Microsoft Windows Vista Home Basic Operating System soft® Windows®7 or later.
Microsoft® Windows® XP Professional Operating System, Service Pack 3 or later Note 5) Multi-display is set, the screen of this product may
® ®
Microsoft Windows XP Home Edition Operating System, Service Pack 3 or later not operate normally.
Note 6) The size of the text or other items on the screen is
Hard disk 1 GB or more of free space not changed to the specified value (96 DPI, 100%,
Communication 9 pt, etc.), the screen of this product may not op-
Use USB port.
interface erate normally.
Note 7) Changed the resolution of the screen during oper-
Resolution 1024 x 768 or more ating, the screen of this product may not operate
Display Must be capable of high color (16-bit) display. normally.
The connectable with the above PC Note 8) Please use by “Standard User,” “Administrator” in
Keyboard The connectable with the above PC Windows Vista® or later.
Note 9) Using a PC for setting Windows®10, upgrade to
Mouse The connectable with the above PC version 1.52E or later.
Printer The connectable with the above PC Using a PC for setting Windows®8.1, upgrade to
USB cable Note 11) LEC-MR-J3USB version 1.25B or later.
Using a PC for setting Windows ®8, upgrade to
version 1.20W or later.
Setup Software Compatible Driver Refer to Mitsubishi Electric Corporation’s website
Setup software for version upgrade information.
Compatible Note 10) If .NET Framework 3.5 (including .NET 2.0 and
MR Configurator™ MR Configurator2™
driver 3.0) have been disabled in Windows®7 or later, it
LEC-MR-SETUP221 LEC-MRC2 is necessary to enable it.
LECSA v v Note 11) Order USB cable separately.
· This cable is compatible with the setup software
LECSB v v
(MR Configurator™: LEC-MR-SETUP221).
LECSC v v
LECSS-S v v
LECSS2-T — v
626 A
LECS /LECSS-T Series
Options
USB cable (3 m)
(LECSA, LECSB, LECSC, LECSS, LECSS-T common)
LEC MR J3USB
* MR-J3USBCBL3M manufactured by Mitsubishi Electric Corporation.
Weight: 140 g
Cable for connecting PC and driver when using the setup
software (MR Configurator2™).
Do not use any cable other than this cable.
Battery (only for LECSB, LECSC or LECSS) Note) The LEC-MR-J3BAT is a single battery that uses lithium metal
battery ER6V.
LEC MR J3BAT When transporting lithium metal batteries and devices with built-in
lithium metal batteries by a method subject to UN regulations, it is
* MR-J3BAT manufactured by Mitsubishi Electric Corporation. necessary to apply measures according to the regulations stipulated
in the United Nations Recommendations on the Transport of
Battery for replacement. Dangerous Goods, the Technical Instructions (ICAO-TI) of the
Absolute position data is maintained by installing the battery to International Civil Aviation Organization (ICAO), and the
the driver. International Maritime Dangerous Goods Code (IMDG CODE) of the
International Maritime Organization (IMO). If a customer is
transporting products such as shown above, it is necessary to
confirm the latest regulations, or the laws and regulations of the
country of transport on your own, in order to apply the proper
Weight: 30 g measures. Please contact SMC sales representative for details.
Battery (only for LECSS2-T) Note) The LEC-MR-BAT6V1SET is an assembled battery that uses
lithium metal battery 2CR17335A.
LEC MR BAT6V1SET When transporting lithium metal batteries and devices with built-in
lithium metal batteries by a method subject to UN regulations, it is
* MR-BAT6V1SET manufactured by Mitsubishi Electric Corporation. necessary to apply measures according to the regulations stipulated
in the United Nations Recommendations on the Transport of
Battery for replacement. Dangerous Goods, the Technical Instructions (ICAO-TI) of the
Absolute position data is maintained by installing the battery to International Civil Aviation Organization (ICAO), and the
International Maritime Dangerous Goods Code (IMDG CODE) of the
the driver.
International Maritime Organization (IMO). If a customer is
transporting products such as shown above, it is necessary to
confirm the latest regulations, or the laws and regulations of the
country of transport on your own, in order to apply the proper
measures. Please contact SMC sales representative for details.
Weight: 60 g
LEC MR D05UDL3M
* MR-D05UDL3M manufactured by Mitsubishi Electric Corporation.
Cable for connecting the driver and device, when using the safety
function.
Do not use any cable other than this cable.
(33) 3000
(50)
ø6.5
Weight: 500 g
B 626-1
LECS Series
Specific Product Precautions 1
Be sure to read this before handling the products. Refer to back page 50 for Safety
Instructions and pages 3 to 8 for Electric Actuator Precautions.
Design/Selection Handling
Warning Warning
1. Use the specified voltage. 9. Static electricity may cause a malfunction or damage
If the applied voltage is higher than the specified voltage, the driver. Do not touch the driver while power is
malfunction and damage to the driver may result. If the applied supplied to it.
voltage is lower than the specified voltage, there is a possibility Take sufficient safety measures to eliminate static electricity when
that the load cannot be moved due to internal voltage drop. Check it is necessary to touch the driver for maintenance.
the operating voltage prior to start. Also, confirm that the operating
voltage does not drop below the specified voltage during operation. 10. Do not use the products in an area where they could be
exposed to dust, metallic powder, machining chips or
2. Do not use the products outside the specifications. splashes of water, oil or chemicals.
Otherwise, fire, malfunction or damage to the driver/actuator can
Otherwise, a failure or malfunction can result.
result. Check the specifications before use.
11. Do not use the products in a magnetic field.
3. Install an emergency stop circuit.
Otherwise, a malfunction or failure can result.
Install an emergency stop outside the enclosure in easy reach to
the operator so that the operator can stop the system operation 12. Do not use the products in an environment where
immediately and intercept the power supply. flammable, explosive or corrosive gases, liquids or
4. To prevent danger and damage due to a breakdown or other substances are present.
malfunction of these products, which may occur at a Otherwise, fire, explosion or corrosion can result.
certain probability, a backup system should be arranged 13. Avoid heat radiation from strong heat sources, such as
in advance by using a multiple-layered structure or by direct sunlight or a hot furnace.
making a fail-safe equipment design etc. Otherwise, it will cause a failure to the driver or its peripheral
5. If there is a risk of fire or personal injury due to devices.
abnormal heat generation, sparking, smoke generated 14. Do not use the products in an environment with cyclic
by the product, etc., cut off the power supply from this temperature changes.
product and the system immediately. Otherwise, it will cause a failure to the driver or its peripheral
devices.
6. The parameters of the driver are set to initial values.
Please change parameters according to the specifica- 15. Do not use the products in an environment where surges
tions of the customer’s equipment before use. are generated.
Refer to the operation manual for details of parameters. Devices (solenoid type lifters, high frequency induction furnaces,
motors, etc.) that generate a large amount of surge around the
product may lead to deterioration or damage to the internal circuits
Handling of the products. Avoid supplies of surge generation and crossed
lines.
Warning
Electric shock, fire or injury can result.
4. Use only the specified combination between the
electric actuator and driver. 1. Install the driver and its peripheral devices on fireproof
Otherwise, it may cause damage to the driver or to the other material.
equipment. Direct installation on or near flammable material may cause fire.
5. Be careful not to touch, get caught or hit by the 2. Do not install these products in a place subject to
workpiece while the actuator is moving. vibration and impact.
An injury can result. Otherwise, a malfunction or failure can result.
6. Do not connect the power supply or power up the 3. The driver should be mounted on a vertical wall in a
product until it is confirmed that the workpiece can be vertical direction.
moved safely within the area that can be reached by Also, do not cover the driver’s suction/exhaust ports.
the workpiece. 4. Install the driver and its peripheral devices on a flat
Otherwise, the movement of the workpiece may cause an accident. surface.
7. Do not touch the product when it is energized and for If the mounting surface is not flat or uneven, excessive force may
some time after the power has been disconnected, as be applied to the housing and other parts resulting in a
it is very hot. malfunction.
Otherwise, it may cause burns due to the high temperature.
8. Check the voltage using a tester at least 5 minutes after
power-off when performing installation, wiring and
maintenance.
Otherwise, electric shock, fire or injury can result.
627
LECS Series
Specific Product Precautions 2
Be sure to read this before handling the products. Refer to back page 50 for Safety
Instructions and pages 3 to 8 for Electric Actuator Precautions.
Caution Warning
1. Use a power supply with low noise between lines and 1. Perform maintenance checks periodically.
between power and ground. Confirm wiring and screws are not loose.
In cases where noise is high, use an isolation transformer. Loose screws or wires may cause unexpected malfunction.
2. Take appropriate measures to prevent surges from 2. Conduct an appropriate functional inspection and test
lightning. Ground the surge absorber for lightning after completed maintenance.
separately from the grounding of the driver and its In case of any abnormalities (if the actuator does not move or the
peripheral devices. equipment does not operate properly etc.), stop the operation of
the system.
Otherwise, unexpected malfunction may occur and safety cannot
Wiring be assured.
Conduct a test of the emergency stop to confirm the safety of the
equipment.
Warning 3. Do not disassemble, modify or repair the driver or its
1. The driver will be damaged if a commercial power peripheral devices.
,
supply (100V/200V) is added to the driver s servo motor 4. Do not put anything conductive or flammable inside
power (U, V, W). Be sure to check wiring such as wiring the driver.
mistakes when the power supply is turned on. Otherwise, fire can result.
2. Connect the ends of the U, V, W wires from the motor 5. Do not conduct an insulation resistance test or
cable correctly to the phases (U, V, W) of the servo insulation withstand voltage test.
motor power. If these wires do not match up, it is
6. Reserve sufficient space for maintenance.
unable to control the servo motor.
Design the system so that it allows required space for
maintenance.
Grounding
Warning
1. For grounding actuator, connect the copper wire of the
,
actuator to the driver s protective earth (PE) terminal
and connect the copper wire of the driver to the earth
,
via the control panel s protective earth (PE) terminal.
,
Do not connect them directly to the control panel s
protective earth (PE) terminal.
Control panel
Driver
PE terminal Actuator
628
Compatible
How to Order
Driver LECY M 2
* If I/O connector (CN1) is required, order
Driver type the part number “LE-CYNA” separately.
* If I/O cable (CN1) is required, order the
MECHATROLINK-2 type part number “LEC-CSNA-1” separately.
M (For absolute encoder)
Compatible motor type
MECHATROLINK-3 type Symbol Type Capacity Encoder
U (For absolute encoder)
V5 AC servo motor (V6 *1) 100 W
V7 AC servo motor (V7 *1) 200 W Absolute
Power supply voltage V8 AC servo motor (V8 *1) 400 W
2 200 to 230 VAC, 50/60 Hz *1 The symbol shows the motor type (actuator).
Dimensions
-@ type
-# type
628-1 A
LECY MU Series
Specifications
-@ Type
Model LECYM2-V5 LECYM2-V7 LECYM2-V8
Compatible motor capacity [W] 100 200 400
Absolute 20-bit encoder
Compatible encoder
(Resolution: 1,048,576 p/rev)
Main circuit power Power voltage [V] Three phase 200 to 230 VAC (50/60 Hz)
supply Allowable voltage fluctuation [V] Three phase 170 to 253 VAC
Power voltage [V] Single phase 200 to 230 VAC (50/60 Hz)
Control power supply
Allowable voltage fluctuation [V] Single phase 170 to 253 VAC
Power supply capacity (at rated output) [A] 0.91 1.6 2.8
Input circuit NPN (Sink circuit)/PNP (Source circuit)
[Initial allocation]
· Homing deceleration switch (/DEC)
· External latch (/EXT 1 to 3)
Number of · Forward run prohibited (P-OT), reverse run prohibited (N-OT)
Parallel input 7
optional
(7 inputs) inputs [Can be allocated by setting the parameters.]
allocations
· Forward external torque limit (/P-CL), reverse external torque limit (/N-CL)
Signal allocations can be performed, and positive and negative logic can be changed.
Number of fixed allocations 1 output · Servo alarm (ALM)
[Initial allocation]
· Lock (/BK)
[Can be allocated by setting the parameters.]
· Positioning completion (/COIN)
· Speed limit detection (/VLT)
Parallel output Number of · Speed coincidence detection (/V-CMP)
(4 outputs) 3
optional · Rotation detection (/TGON)
outputs
allocations · Warning (/WARN)
· Servo ready (/S-RDY)
· Near (/NEAR)
· Torque limit detection (/CLT)
Signal allocations can be performed, and positive and negative logic can be changed.
Communication protocol MECHATROLINK-2
Station address 41H to 5FH
Transmission speed 10 Mbps
MECHATROLINK
Transmission cycle 250 μs, 0.5 ms to 4 ms (Multiples of 0.5 ms)
communication
Number of transmission bytes 17 bytes, 32 bytes
Max. number of stations 30
Cable length Overall cable length: 50 m or less, Cable length between the stations: 0.5 m or more
Control method Position, speed, or torque control with MECHATROLINK-2 communication
Command method MECHATROLINK-2 command
Command input
(Motion, data setting, monitoring or adjustment)
Gain adjustment Tuning-less/Advanced autotuning/One-parameter tuning
Communication setting USB communication, RS-422 communication
Torque limit Internal torque limit, external torque limit, and torque limit by analog command
Function Encoder output Phase A, B, Z: Line driver output
Emergency stop CN8 Safety function
Overtravel Dynamic brake stop, deceleration to a stop, or free run to a stop at P-OT or N-OT
Alarm Alarm signal, MECHATROLINK-2 command
Operating temperature range [°C] 0 to 55 (No freezing)
Operating humidity range [%RH] 90 or less (No condensation)
Storage temperature range [°C] –20 to 85 (No freezing)
Storage humidity range [%RH] 90 or less (No condensation)
Insulation resistance [MΩ] 10 MΩ (500 VDC)
Weight [g] 900 1000
A 628-2
AC Servo Motor Driver LECY MU Series
Specifications
-# Type
Model LECYU2-V5 LECYU2-V7 LECYU2-V8
Compatible motor capacity [W] 100 200 400
Absolute 20-bit encoder
Compatible encoder
(Resolution: 1,048,576 p/rev)
Main circuit power Power voltage [V] Three phase 200 to 230 VAC (50/60 Hz)
supply Allowable voltage fluctuation [V] Three phase 170 to 253 VAC
Power voltage [V] Single phase 200 to 230 VAC (50/60 Hz)
Control power supply
Allowable voltage fluctuation [V] Single phase 170 to 253 VAC
Power supply capacity (at rated output) [A] 0.91 1.6 2.8
Input circuit NPN (Sink circuit)/PNP (Source circuit)
[Initial allocation]
· Homing deceleration switch (/DEC)
· External latch (/EXT 1 to 3)
Number of · Forward run prohibited (P-OT), reverse run prohibited (N-OT)
Parallel input 7
optional
(7 inputs) inputs [Can be allocated by setting the parameters.]
allocations
· Forward external torque limit (/P-CL), reverse external torque limit (/N-CL)
Signal allocations can be performed, and positive and negative logic can be changed.
Number of fixed allocations 1 output · Servo alarm (ALM)
[Initial allocation]
· Lock (/BK)
[Can be allocated by setting the parameters.]
· Positioning completion (/COIN)
· Speed limit detection (/VLT)
Parallel output Number of · Speed coincidence detection (/V-CMP)
(4 outputs) 3
optional · Rotation detection (/TGON)
outputs
allocations · Warning (/WARN)
· Servo ready (/S-RDY)
· Near (/NEAR)
· Torque limit detection (/CLT)
Signal allocations can be performed, and positive and negative logic can be changed.
Communication protocol MECHATROLINK-3
Station address 03H to EFH
Transmission speed 100 Mbps
MECHATROLINK
Transmission cycle 125 μs, 250 μs, 500 μs, 750 μs, 1 ms to 4 ms (Multiples of 0.5 ms)
communication
Number of transmission bytes 16 bytes, 32 bytes, 48 bytes,
Max. number of stations 62
Cable length Cable length between the stations: 0.5 m or more, 75 m or less
Control method Position, speed, or torque control with MECHATROLINK-3 communication
Command method MECHATROLINK-3 command
Command input
(Motion, data setting, monitoring or adjustment)
Gain adjustment Tuning-less/Advanced autotuning/One-parameter tuning
Communication setting USB communication, RS-422 communication
Torque limit Internal torque limit, external torque limit, and torque limit by analog command
Function Encoder output Phase A, B, Z: Line driver output
Emergency stop CN8 Safety function
Overtravel Dynamic brake stop, deceleration to a stop, or free run to a stop at P-OT or N-OT
Alarm Alarm signal, MECHATROLINK-3 command
Operating temperature range [°C] 0 to 55 (No freezing)
Operating humidity range [%RH] 90 or less (No condensation)
Storage temperature range [°C] –20 to 85 (No freezing)
Storage humidity range [%RH] 90 or less (No condensation)
Insulation resistance [MΩ] 10 MΩ (500 VDC)
Weight [g] 900 1000
628-3 A
LECY MU Series
1QF
3SA
U
1FLT V M
2KM
L1 W
L2
L3
1KM
L1C ENC
L2C
1KM 1SA
2KM
1KM 1Ry
1Ry : Relay
2SA
1PL : Indicator light
1QF : Molded-case circuit breaker 1SA : Surge absorber
1FLT: Noise filter 2SA : Surge absorber
1KM : Magnetic contactor (for control power supply) 3SA : Surge absorber
2KM : Magnetic contactor (for main circuit power supply) 1D : Flywheel diode
* For the LECYl2-V5, LECYl2-V7 and LECYl2-V8, terminals B2 and B3 are not short-circuited.
Do not short-circuit these terminals.
Main circuit
power supply connector
Main Circuit Power Supply Connector * Accessory
Terminal name Function Details
L1
L1 Connect the main circuit power supply.
Main circuit power
L2 Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1, L2
supply
L3 Three phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1, L2, L3 L2
L1C Connect the control power supply.
Control power supply
L2C Single phase 200 to 230 VAC, 50/60 Hz Connection terminal: L1C, L2C L3
B1/ + External regenerative
When the regenerative resistor is required, connect it
B2 resistor
between terminals B1 + and B2. L1C
B3 connection terminal
−1 Main circuit negative
− 1 and − 2 are connected at shipment.
−2 terminal L2C
A 628-4
AC Servo Motor Driver LECY MU Series
Photo-coupler output
Max. operating voltage: 30 VDC
LECYM2 Max. output current: 50 mA DC
CN1
Control power supply
for sequence signal +24 VIN +24 V 6 3.3 kΩ 3 ALM+
Alarm output
Note 2)
Forward run prohibited 4 ALM– (OFF when alarm occurs)
P-OT 7
(Prohibited when OFF) 1 SO1+/BK+
Lock output
Reverse run prohibited N-OT 8 2 SO1–/BK–
(ON when lock released)
(Prohibited when OFF) 23 /SO2+
Switch CN8
/HWBB1+ 4
24 V
Fuse
/HWBB1– 3
8 EDM1+
Safety Note 3)
Note 5) /HWBB2+ 6
7
EDM1–
/HWBB2– 5
0V
Driver
Connector
shell
FG Connect shield to connector shell.
628-5 A
LECY MU Series
Photo-coupler output
Max. operating voltage: 30 VDC
LECYU2 Max. output current: 50 mA DC
CN1
Control power supply
for sequence signal +24 VIN +24 V 6 3.3 kΩ 3 ALM+
Alarm output
Note 2)
Forward run prohibited 4 ALM– (OFF when alarm occurs)
P-OT 7
(Prohibited when OFF) 1 SO1+/BK+
Lock output
Reverse run prohibited N-OT 8 2 SO1–/BK–
(ON when lock released)
(Prohibited when OFF) 23 /SO2+
Switch
CN8
/HWBB1+ 4
24 V
Fuse
/HWBB1– 3
8 EDM1+
Safety Note 3)
Note 5) /HWBB2+ 6
7
EDM1–
/HWBB2– 5
0V
Driver
Connector
shell
FG Connect shield to connector shell.
A 628-6
AC Servo Motor Driver LECY MU Series
Options
Motor cable, Motor cable for lock option, Encoder cable (LECYM/LECYU common)
LE CY M S 5 A 5
Motor type Motor capacity
Y AC servo motor 5 100 W
7 200/400 W
Cable description * For encoder cable, the suffix “–l” (Motor capacity) is not necessary.
M Motor cable
B Motor cable for lock option
Direction of connector
Encoder cable
E Axis side
(With battery case)
Cable type A
S Standard cable
R Robotic cable
Cable length (L) [m] * The cable entry direction is axis side only.
3 3 Weight
5 5 Product no. Length [m] Weight [g] Note
A 10 LE-CYM-S3A-5 3 250
C 20 LE-CYM-S5A-5 5 390
100 W
LE-CYM-SAA-5 10 750
LE-CYM-SCA-5 20 1500
LE-CYM-S3A-7 3 250
LE-CYM-llA-l: Motor cable LE-CYM-S5A-7 5 390 200/
LE-CYM-SAA-7 10 750 400 W
L 50
LE-CYM-SCA-7 20 1500
LE-CYM-R3A-5 3 220
ø7
U
LE-CYM-R5A-5 5 350
100 W
V LE-CYM-RAA-5 10 670
W LE-CYM-RCA-5 20 1300
G LE-CYM-R3A-7 3 220
M4 Crimped terminal LE-CYM-R5A-7 5 350 200/
LE-CYM-RAA-7 10 670 400 W
LE-CYM-RCA-7 20 1300
LE-CYB-llA-l: Motor cable for lock option Weight
L 50 Product no. Length [m] Weight [g] Note
LE-CYB-S3A-5 3 240
ø7
LE-CYB-S5A-5 5 390
100 W
LE-CYB-SAA-5 10 750
LE-CYB-SCA-5 20 1490
LE-CYB-S3A-7 3 240
LE-CYB-S5A-7 5 390 200/
LE-CYB-SAA-7 10 750 400 W
3-M4 Crimped terminal LE-CYB-SCA-7 20 1490
LE-CYB-R3A-5 3 220
LE-CYB-R5A-5 5 350
LE-CYE-llA: Encoder cable LE-CYB-RAA-5 10 670
100 W
L LE-CYB-RCA-5 20 1300
(60) (100) LE-CYB-R3A-7 3 220
LE-CYB-R5A-7 5 350 200/
12 LE-CYB-RAA-7 10 670 400 W
(7)
LE-CYB-RCA-7 20 1300
øD
Weight
19
2 1
4 3
6 5
LE-CYE-S5A 5 360
LE-CYE-SAA 10 680
Product no. øD Battery case LE-CYE-SCA 20 1250
Depth dimension: 25 mm LE-CYE-R3A 3 220
LE-CYE-SlA 6.5 LE-CYE-R5A 5 330
LE-CYE-RlA 6.8 LE-CYE-RAA 10 660
LE-CYE-RCA 20 1240
* LE-CYM-SlA-l is JZSP-CSM0l-ll-E manufactured by YASKAWA CONTROLS CO., LTD. LE-CYM-RlA-l is JZSP-CSM2l-ll-E manufactured by YASKAWA CONTROLS CO., LTD.
LE-CYB-SlA-l is JZSP-CSM1l-ll-E manufactured by YASKAWA CONTROLS CO., LTD. LE-CYB-RlA-l is JZSP-CSM3l-ll-E manufactured by YASKAWA CONTROLS CO., LTD.
LE-CYE-SlA is JZSP-CSP05-ll-E manufactured by YASKAWA CONTROLS CO., LTD. LE-CYE-RlA is JZSP-CSP25-ll-E manufactured by YASKAWA CONTROLS CO., LTD.
628-7 B
LECY MU Series
Options
I/O connector (Without cable, Connector only)
LE CYN A LE-CYNA
Driver type
37.2
A LECYM2, LECYU2
39
* LE-CYNA: 10126-3000PE (connector)/10326-52F0-008 (shell kit) manufactured by 3M Japan Limited or equivalent item.
* Conductor size: AWG24 to 30
I/O cable
LEC CSN A 1
Driver type
A LECYM2, LECYU2 Cable length (L) [m]
1 1.5
T 100 80
U W 1500
A side B side
Wiring
LEC-CSNA-1: Pin no. 1 to 26
Connector Pair no. Insulation Dot Connector Pair no. Insulation Dot Connector Pair no. Insulation Dot
Dot mark Dot mark Dot mark
pin no. of wire color color pin no. of wire color color pin no. of wire color color
1 Red 11 Red 21 Red
1 Orange 6 Orange 11 Orange
2 Black 12 Black 22 Black
A side
A side
A 628-8
AC Servo Motor Driver LECY MU Series
Options
cable type
LEC CY M 1
Motor type Cable length (L)
Y AC servo motor L* 0.2 m
J 0.5 m
Cable description 1 1m
M MECHATROLINK-2cable 3 3m
U MECHATROLINK-3cable * Not available for the
MECHATROLINK-2cable.
-@ cable
L Weight
Product no. Length [m] Weight [g]
16
LE-CYM-J 0.5 50
ø4
LE-CYM-1 1 80
19
LE-CYM-3 3 200
46
-# cable
33 L Weight
Product no. Length [m] Weight [g]
ø4.8
LE-CYU-L 0.2 21
LE-CYU-J 0.5 41
LE-CYU-1 1 75
11
10.7
LE-CYU-3 3 205
LEC CYRM
* LEC-CYRM is JEPMC-W6022-E manufactured by YASKAWA CONTROLS CO., LTD.
19
16
46 Weight: 10 g
628-9 B
LECY MU Series
Options
USB cable
PC
LECYM2 LECYU2
Drivers
Adjustment, waveform display, parameter read/write, and test operation can be performed upon a PC.
Compatible PC
When using setup software (SigmaWin+TM), use an IBM PC/AT compatible PC that meets the following operating conditions.
Hardware Requirements
Equipment Setup software (SigmaWin+TM)
OS Windows® XP Note 5), Windows Vista®, Windows® 7 (32-bit/64-bit)
Note 1) 2) 3) 4)
PC Available HD space 350 MB or more (When the software is installed, 400 MB or more is recommended.)
Communication interface Use USB port.
XVGA monitor (1024 x 768 or more, “The small font is used.”)
Display 256 color or more (65536 color or more is recommended.)
The connectable with the above PC
Keyboard The connectable with the above PC
Mouse The connectable with the above PC
Printer The connectable with the above PC
USB cable LEC-JZ-CVUSB Note 6)
Other Adobe Reader Ver. 5.0 or higher (* Except Ver. 6.0)
Note 1) Windows, Windows Vista®, Windows® 7 are registered trademarks of Microsoft Corporation in the United States and/or other countries.
Note 2) On some PCs, this software may not run properly.
Note 3) Not compatible with 64-bit Windows® XP and 64-bit Windows Vista®.
Note 4) For Windows® XP, please use it by the administrator authority (When installing and using it.).
Note 5) In PC that uses the program to correct the problem of HotfixQ328310, it is likely to fail in the installation. In that case, please use the program to
correct the problem of HotfixQ329623.
Note 6) Order USB cable separately.
Battery (LECYM/LECYU common) Note) The LEC-JZ-CVBAT is a single battery that uses lithium metal
battery ER3V.
LEC JZ CVBAT When transporting lithium metal batteries and devices with built-in
lithium metal batteries by a method subject to UN regulations, it is
* JZSP-BA01 manufactured by YASKAWA CONTROLS CO., LTD.
necessary to apply measures according to the regulations stipulated
Battery for replacement. in the United Nations Recommendations on the Transport of
Absolute position data is maintained by installing the battery to Dangerous Goods, the Technical Instructions (ICAO-TI) of the
International Civil Aviation Organization (ICAO), and the
the battery case of the encoder cable.
International Maritime Dangerous Goods Code (IMDG CODE) of the
International Maritime Organization (IMO). If a customer is
transporting products such as shown above, it is necessary to
confirm the latest regulations, or the laws and regulations of the
country of transport on your own, in order to apply the proper
Weight: 10 g measures. Please contact SMC sales representative for details.
ø6
Weight: 160 g
(100) (55)
Weight: 150 g
B 628-10
LECYM/LECYU Series
AC Servo Motor Driver/
Specific Product Precautions 1
Be sure to read this before handling the products. Refer to back page 50 for Safety
Instructions and pages 3 to 8 for Electric Actuator Precautions.
Design/Selection Handling
Warning Warning
1. Use the specified voltage. 9. Static electricity may cause a malfunction or damage
If the applied voltage is higher than the specified voltage, the driver. Do not touch the driver while power is
malfunction and damage to the driver may result. If the applied supplied to it.
voltage is lower than the specified voltage, there is a possibility Take sufficient safety measures to eliminate static electricity when
that the load cannot be moved due to internal voltage drop. Check it is necessary to touch the driver for maintenance.
the operating voltage prior to start. Also, confirm that the operating
voltage does not drop below the specified voltage during operation. 10. Do not use the products in an area where they could be
exposed to dust, metallic powder, machining chips or
2. Do not use the products outside the specifications. splashes of water, oil or chemicals.
Otherwise, fire, malfunction or damage to the driver/actuator can
Otherwise, a failure or malfunction can result.
result. Check the specifications before use.
11. Do not use the products in a magnetic field.
3. Install an emergency stop circuit.
Otherwise, a malfunction or failure can result.
Install an emergency stop outside the enclosure in easy reach to
the operator so that the operator can stop the system operation 12. Do not use the products in an environment where
immediately and intercept the power supply. flammable, explosive or corrosive gases, liquids or
4. To prevent danger and damage due to a breakdown or other substances are present.
malfunction of these products, which may occur at a Otherwise, fire, explosion or corrosion can result.
certain probability, a backup system should be arranged 13. Avoid heat radiation from strong heat sources, such as
in advance by using a multiple-layered structure or by direct sunlight or a hot furnace.
making a fail-safe equipment design etc. Otherwise, it will cause a failure to the driver or its peripheral
5. If there is a risk of fire or personal injury due to devices.
abnormal heat generation, sparking, smoke generated 14. Do not use the products in an environment with cyclic
by the product, etc., cut off the power supply from this temperature changes.
product and the system immediately. Otherwise, it will cause a failure to the driver or its peripheral
devices.
628-11 A
LECYM/LECYU Series
AC Servo Motor Driver/
Specific Product Precautions 2
Be sure to read this before handling the products. Refer to back page 50 for Safety
Instructions and pages 3 to 8 for Electric Actuator Precautions.
Caution Warning
1. Use a power supply with low noise between lines and 1. Perform maintenance checks periodically.
between power and ground. Confirm wiring and screws are not loose.
In cases where noise is high, use an isolation transformer. Loose screws or wires may cause unexpected malfunction.
2. Take appropriate measures to prevent surges from 2. Conduct an appropriate functional inspection and test
lightning. Ground the surge absorber for lightning after completed maintenance.
separately from the grounding of the driver and its In case of any abnormalities (if the actuator does not move or the
peripheral devices. equipment does not operate properly etc.), stop the operation of
the system.
Otherwise, unexpected malfunction may occur and safety cannot
Wiring be assured.
Conduct a test of the emergency stop to confirm the safety of the
equipment.
Warning 3. Do not disassemble, modify or repair the driver or its
1. The driver will be damaged if a commercial power peripheral devices.
,
supply (100V/200V) is added to the driver s servo motor 4. Do not put anything conductive or flammable inside
power (U, V, W). Be sure to check wiring such as wiring the driver.
mistakes when the power supply is turned on. Otherwise, fire can result.
2. Connect the ends of the U, V, W wires from the motor 5. Do not conduct an insulation resistance test or
cable correctly to the phases (U, V, W) of the servo insulation withstand voltage test.
motor power. If these wires do not match up, it is
6. Reserve sufficient space for maintenance.
unable to control the servo motor.
Design the system so that it allows required space for
maintenance.
Grounding
Warning
1. For grounding actuator, connect the copper wire of the
,
actuator to the driver s protective earth (PE) terminal
and connect the copper wire of the driver to the earth
,
via the control panel s protective earth (PE) terminal.
,
Do not connect them directly to the control panel s
protective earth (PE) terminal.
Control panel
Driver
PE terminal Actuator
A 628-12