APC-504 – BRAZZOLI

INNODYE HT MACHINE GENERAL

PNEUMATIC VALVES LIST

FUNCTION
.AREL No BRAZZOLI No REMARKS

MACHINE

FILL 1 V1
101
FILL 2 V2
102
FILL 3 V3
103
FILL ISOLATE V4
182 MOD, 4-20mA

OVERFLOW V5
107
VENTILATION V10C
140
NORMAL DRAIN V7A 111A

POWER DRAIN 1 V7D


111
POWER DRAIN 2 V7DW
112
.DRAIN INTERM V72
748
SPRAY VALVE VSPRAY 176A

TURBO VARIO VTV 186P/A MOD 4-20mA

DRAIN COOL RINSE VDCD 111B

AIR RELEASE V10


108

HEAT EXCHANGER

HEAT VH
116 MOD 4-20mA

COOL VC
117 MOD 4-20mA

DIRECT COOL VDC


134

AUX. TANK

.FILL AUX. ISOL V4A


750
TRANSFER V25
745
DRAIN V24
711

Page 1
APC-504 – BRAZZOLI
INNODYE HT MACHINE GENERAL

FUNCTION
.AREL No BRAZZOLI No REMARKS

HEAT VH20
716

TANK 1

RINSE VT6
131
RECIRCULATION VT6A
141
TRANSFER VT1
145
.RECIRCULATE TO AUX VT6B 141A

TANK 2

RINSE VT7
401
RECIRCULATION VT7A
451
TRANSFER VT2
431
DOSING TO TANK 1 VDOS21 136A

DRUG ROOM

SLOW TRANSFER TO MACHINE VT9S


136
FAST TRANSFER TO MACHINE VT9
137
DRAIN VDR
146
.TRANSFER TO AUX VT9A
738

MOTORS

MAIN PUMP P
201 DIGITAL OUT. + 4-20mA

ROLLER 1 R1
231 DIGITAL OUT. + 4-20mA

ROLLER 2 R2
232 DIGITAL OUT. + 4-20mA

ROLLER 3 R3
233 DIGITAL OUT. + 4-20mA

PUMP CHARGE TANK PTA


730 .DIGITAL OUT
PUMP TANK 1 PT1
203 .DIGITAL OUT
PUMP TANK 2 PT2 203A
.DIGITAL OUT
MIXER TANK 1 MIX1
241 .DIGITAL OUT

Page 2
APC-504 – BRAZZOLI
INNODYE HT MACHINE GENERAL

FUNCTION
.AREL No BRAZZOLI No REMARKS

MIXER TANK 2 MIX2


511 .DIGITAL OUT

DIGITAL SENSORS

FLOWMETER FW
282 PULSE DRY CONTACT

FEEDBACK MAIN PUMP FBP DRY CONTACT

FEEDBACK ROLLER 1 FBR1

FEEDBACK ROLLER 2 FBR2

FEEDBACK ROLLER 3 FBR3

SEAM 1 SM1

SEAM 2 SM2

SEAM 3 SM3

ANALOG SENSORS

PT100 MACHINE TEMPERATURE SNS. PT100A

PT100 CHARGE TANK TEMP. SNS PT100B

MACHINE–ANALOG LEVEL SENSOR LMA 4-20mA

CHARGE TANK–ANALOG LEVEL SENSOR LTAX 4-20mA

TANK 1–ANALOG LEVEL SENSOR LTA1 4-20mA

TANK 2–ANALOG LEVEL SENSOR LTA2 4-20mA

"N.C." - for normally closed valve, spring return Legend:


N.O." - for normally open valve, spring return"
D.A." - for double acting valve"
MOD." - for modulating valve"

Page 3
APC-504 – BRAZZOLI
INNODYE HT MACHINE GENERAL

DYE PROGRAM FORMAT

Yes / No............................................................ PREPARE TANK 1

Yes / No................................................................... MIX TANK 1

Yes / No............................................................ PREPARE TANK 2

Yes / No................................................................... MIX TANK 2

Yes / No........................................PREFILL TANKS WITH FRESH WATER

Yes / No............................................. PREFILL TANKS FROM MACHINE

Yes / No..................................... POST FILL TANKS WITH FRESH WATER

Yes / No...........................................POST FILL TANKS FROM MACHINE

_ _.............................................OPERATOR MESSAGE PREPARE


Yes / No.......................................... TRANSFER TANK 1 TO AUX. TANK

Yes / No.......................................... TRANSFER TANK 2 TO AUX. TANK

Yes / No............................................. FILL AUX. WITH WATER TYPE 1

Yes / No............................................. FILL AUX. WITH WATER TYPE 2

Yes / No............................................. FILL AUX. WITH WATER TYPE 3

_ . _ _.............................................................. FILL AUX. RATIO


._ _ _ _ L......................................................... FILL AUX. QUANTITY
_ _ _Deg.C............................................................. HEAT AUX. TANK

Yes / No............................................................ MIXER AUX. TANK

Yes / No.....................................RECIRCULATION TANK 1 TO AUX. TANK

_ _ _Deg.C............................................................ DRAIN AUX. TANK

Yes / No...........................WAIT FOR HEAT AUX. TANK BEFORE TRANSFER

Yes / No........................................ TRANSFER AUX. TANK TO MACHINE

Yes / No........................................ FILL MACHINE WITH WATER TYPE 1

Yes / No........................................ FILL MACHINE WITH WATER TYPE 2

Yes / No........................................ FILL MACHINE WITH WATER TYPE 3

_ _.................................................................... FILL RATIO


._ _ _ _ L............................................................... FILL QUANTITY
Yes / No............................................................... FILL TO LEVEL 1

Yes / No.............................................................. FILL TO LEVEL 2

Yes / No.............................................................. FILL TO LEVEL 3

Yes / No................................................................. LOAD FABRIC

_ _............................................... OPERATOR MESSAGE - LOAD


Yes / No...................................................... MACHINE PRESSURIZE

Page 4
APC-504 – BRAZZOLI
INNODYE HT MACHINE GENERAL

% _ _ _........................................................... MAIN PUMP SPEED


% _ _ _................................................................ ROLLER SPEED
Yes / No................................................................. SPRAY VALVE

Yes / No........................................................... WORK BY CYCLES

._ _._ Deg.C /min.......................................................................... RATE


_ _ _ Deg.C............................................................... TEMPERATURE

Yes / No.................................................................. COOL RINSE

Yes / No............................................... HEAT CONTROL IN TRANSFER

Yes / No..................................................... RECIRCULATION TANK 1

Yes / No..................................................... RECIRCULATION TANK 2

Yes / No........................................................... TRANSFER TANK 1

Yes / No........................................................... TRANSFER TANK 2

._ _ _ min................................................................. DOSING TIME


_ _.............................................................. DOSING CURVE
Yes / No........................................................ DOSING FROM TANK 1

Yes / No........................................................ DOSING FROM TANK 2

_ _ _ min.................................................................... HOLD TIME

Yes / No................................................. RINSE WITH WATER TYPE 1

Yes / No................................................. RINSE WITH WATER TYPE 2

Yes / No................................................. RINSE WITH WATER TYPE 3

._ _ _ _ L............................................................. RINSE QUANTITY


_ _.................................................................. RINSE RATIO
._ _ _ min.................................................................... RINSE TIME
Yes / No.........................................CONTROLLED RINSE BY FILL VALVE

Yes / No.................................................................... SAMPLING

_ _....................................................... OPERATOR MESSAGE


Yes / No.................................................................. UNLOADING

Yes / No........................................UNLOADING WITH SEAM DETECTION

_ _....................................................... OPERATOR MESSAGE


Yes / No................................................................... FULL DRAIN

Yes / No............................................................... POWER DRAIN 1

Yes / No............................................................... POWER DRAIN 2

Page 5