You are on page 1of 6
1 + SEE REVERSE SIDE OF PAGE FOR LIST OF HIGH-SEISMIC ZIP CODES, SHEET | (HS) (REV. 01/10) ‘BUILDING PERMIT REQUIRED. 2, FENCE HEIGHTS MAY ALSO BE REGULATED BY THE ZONING LAWS OF THE CITY. FOR SPECIFIC INFORMATION ABOUT THE ZONING REGULATIONS FOR YOUR FENCE ON YOUR LOT, CONTACT THE DEVELOPMENT SERVICES AND ZONING DEPARTMENTS FOR REQUIREMENTS. RCP BLOCK é& BRICK INC. CONCRETE BLOCK FENCE WALL SPECS. FOR STANDARD 8’ HIGH CMU FENCE MASTER PLAN #47-8 HIGH SEISMIC WITH ZIP CODES* 1. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE CALIFORNIA BUILDING CODE. 2007 EDITION. NOTE: WALLS SHALL RECEIVE "LEVEL 1” SPECIAL INSPECTION AS REQ'D. BY CHAPTERS 17 & 21 OF THE 2007 CBC. (SEE CHECKUIST ATTACHED) 2, CONCRETE SHALL ATIAN A COMPRESSIVE STRENGTH OF 2,500 PSI MINIMUM AT 28 DAYS. 3. CONCRETE BLOCK UNITS SHALL BE MEDIUM OR NORMAL WEIGHT UNITS CONFORMING TO ASTM C90 (LATEST REVISION), Fm = 1500 PSI 4, MORTAR SHALL BE TYPE S CONFORMING TO ASTM C270 WITH A COMPRESSIVE STRENGTH OF 1,800 PSI MINIMUM AT 2 8 DAYS. 5. GROUT SHALL CONFORM TO ASTM C476 AND BE COMPOSED OF THE FOLLOWING RATIO BY VOLUME: 1 PART PORTLAND CENENT, 3-PARTS SAND, 2-PARTS PEA GRAVEL, AND SUFFICIENT WATER FOR POURING WTHOUT SEGREGATION OF GROUT CONSTITUENTS (WIN. COMPRESSIVE STRENGTH OF 2,000 PSI AT 28 DAYS). 6, ALL REINFORCING STEEL SHALL COMPLY WITH ASTM AGI5, GRADE 40 FOR #3 BARS AND GRADE 60 FOR #4 BARS A ND LARGER, VERTICAL STEEL SHALL BE CENTERED IN THE CONCRETE BLOCK CELL IN WHICH IT IS LOCATED, U.O.N, 7. WALL JOINT REINFORCING STEEL SHALL BE DUR—O-WAL WIRE CONFORMING TO ASTM AB2 AND ASTM A641. — STANDARD, MILL GALVANIZED. MINIMUM LAP SPLICE OF JOINT REINFORCEMENT SHALL BE 12 INCHES. 8, ONLY CELLS CONTAINING REINFORCING STEEL SHALL BE SOLID GROUTED. 9. ALL HORIZONTAL WALL REINFORCING BARS SHALL BE PLACED IN BOND BEAM UNITS, ALL JOINT REINFORCING SHALL BE PLACED IN THE MORTARED BED JOINT. TOLALL GROUT SHALL BE CONSOLIDATED BY VIBRATING INMEDIATELY. RECONSOLIDATE GROUT AFTER INITAL WATER LOSS BUT BEFORE PLASTICITY IS LOST TO INSURE ADEQUATE CONSOLIDATION. TILMINIMUM LAP SPLICE OF REINFORCING BARS SHALL BE 48 DIAMETERS. 12. CONCRETE BLOCK UNITS ARE TO BE STAGGERED (COMMON BOND) AND ARE TO HAVE THE VERTICAL CONTINUITY OF ‘THE CELLS UNOBSTRUCTED. 13.ALL FOOTINGS MUST EXTEND INTO FIRM UNDISTURBED NATURAL SOIL OR SOIL WHICH HAS BEEN COMPACTED TO AT LEAST 90 PERCENT MAXIMUM DENSITY. 14. THESE WALLS SHALL NOT BE CONSTRUCTED ON EXPANSIVE SOIL (EXPANSION INDEX GREATER THAN 20) UNLESS THE SOIL HAS BEEN SPECIALLY PREPARED IN ACCORDANCE WITH RECOMMENDATIONS OF A CIVIL OR GEOTECHNICAL ENGINEER. THESE WALLS SHALL NOT BE CONSTRUCTED ON LIQUEFIABLE SOILS OR OTHER QUESTONABLE SOILS. 15, PROVIDE VERTICAL CONTROL JOINTS AT 25'-0" ON CENTERS MAXIMUNL 16.FENCE WALL DESIGN INCLUDES 1/2" OF PLASTER (OR VENEER) ON EACH SIDE OF THE WALL. NO FINISHES WITH A TOTAL WEIGHT GREATER THAN 13 PSF (SUMMATION OF BOTH SIDES OF WALL) ARE ALLOWED, RCP BLOCK & BRICK INC. CONCRETE BLOCK FENCE WALL SPECS. FOR STANDARD 8’ HIGH CMU FENCE (HIGH-SEISMIC ZIP CODES) 92036 Julian 92037 La Jolla 92038 La Jolla 92039 La Jolla 92059 Pala 92060 Palomar Mountain 92066 Warner Springs 92070 Santa Ysabel 92092 La Jolla 92093 La Jolla 92101 San Diego 92103 San Diego 92109 Pacific Beach 92110 San Diego 92111 San Diego 92112 San Diego 92117 San Diego 92118 Coronado 92122 San Diego 92132 San Diego 92133 San Diego 92134 San Diego 92137 San Diego 92138 San Diego 92140 San Diego 92147 San Diego 92155 San Diego 92161 San Diego 92163 San Diego 92168 San Diego 92169 San Diego 92171 San Diego 92177 San Diego 92178 Coronado 92184 San Diego 92186 Son Diego 92187 San Diego SHEET 2 (HS) (REV. O10) STRUCTURAL TESTS AND SPECIAL INSPECTIONS ‘TABLE t70¢51 LEVEL 1 SPECIAL INSPECTION, FREBUENDY OF WSPECTON rereeies Fon chen oninsar | Peay Simgest | Sei! we | acrmoasee | acts msreonow rae og | Oe sion _| “Galas | AQ As masonry onvncion bis, be ong al 1 [Reverie cone competes = 3 a. Proportions ofsite prepared mortar, ae x = ~ Ast 2.68, HE 6. Constction of mortar joins, = x = = | anaz | «Lost ftsnforement, comer * ‘Prestressing tendons and anchorages. - x - =| An sa.scn Previn cig ae = — [aes Grae nd in of pescaag eden nd _ . ~ | Anam, ciorapes ait The iaepctin progam al ven r Ke Sie sed oaion of sent elonts = x a asset asus 1 Typ ea icatn af anchor ncdeg cfr def schorage of mater . x - o structaral members, frames or other construction l | Ke specitied size, grade and yyo of reinforcement ia x = sees | a 2430 Welding of ifr bs. a _ foezztona ea _ x a 3.33.40) © Fromalonof mony ding col wae * Gomperature below 40°F) or bot weather ae Et ana ree {pase sow 907, | Ames nd measaomort of pening foros | x 3 ease ata 5. Pott grting he owing ca velo taste cele [FA Grout space i ean = x = ~ Ax.320 | 3F b. Placement of reinforcement and connsctore and af tenes ae ome = fox | = | seus | se AK Proprio of tered grou ma penning grout for bonded tendans, oe x fH ata Att, 2.68 IK & consencion of mona oa = x = — | Ansan I. outplacement sal be veri care eorince with code and constriction document provisions, x ee fe 1 iain Anas 1 Growl estesing bonded ends. x = = — | wes 5 Preparation of ny id grot pein omar se, 210522, specimens and/or pristns shall be observed. = saa 2105.3 it Arle SK le counts tains mein onsets Consration cama an eggs nla | x = eee ees Soa te vee RaSt CaCF-308, The epost anv eferanced ae Ue ted in Chap 28 2007 CALIFARNIE RI nie nae KP ere Ispecnon TASK eas. REFEREE Onley \ da | ‘STRUCTURAL TESTS AND SPECIAL INSPECTIONS Sows Taste 17067 [REQUIRED VERIFICATION AND INSPECTION OF SOILS. | ‘enronTow ns nareonOwTAs eowrewous uni rsx TE] | i i | | i esi becng capaci. a _ = x fa. Verify excavations are exended wo proper depth and have eachod proper materia 3: Perform casifiaton and testing of conte fill materials a x * 1. Verity materials below footings are adequate to achieve the 4, Verify use of proper materials, denies and it thicknesses uring placenset aad compietion of contelled fl. x = |S. Briocto placement of eanlled fil, observe subgrace and >| very thar ste bat been prepered propery, = z i 1 3K Scene Ispécnen Tasks Rea's, Statement of Special Inspection (Fe REFEA=ce omy) — : 1. The special inspector must be certified by the City of San Diego, Development | Services, in the category of work required to have special inspection. | 2. ‘The construction materials testing laboratory must be approved by the City of San Diego, Development Services, for testing of materials, systems, components, and equipments, 3. A Property Owner's Final Report form for work required to have special inspections, testing, and structural observations must be completed by the property owner, property owner's agent of record, architect-of-record, engineer. | of-record and submitted to the inspection services division. ~ 4, The special inspections identified on plans are, in addition to; and not a substitute for, those inspections required to-be performed by a City’s building inspector. 5. Minimum specified compressive strength of Masonry (P'm) at age of 28 days shall be 1,500 psi. 6. Soils special inspection shall be performed by the registered design professional in responsible charge (Soils engineer or Geotechnical engineer-of-record), who has prepared the approved geotechnical investigation report 7. When there is no geotechnical investigation report prepared for this project, the registered design professional-of-record must identify the soils-class and design parameters in accordance with Table 1804.2. The registered design professional of record must then state that site visits) has been made and to identity the soils class, allowable foundation bearing pressure, and lateral soil pressure for this project. 2007 CALIFORNIA BUILDING CODE Nb RCP BLOCK & BRICK, INC. CONCRETE BLOCK FENCE — 8’—0” HIGH MAXIMUM (HIGH—-SEISMIC ZIP CODES) —Bx2xlo CAP H (2) -*4 @ TOP " WIDE CONCRETE BLOCK ~*4 © 24" EA. FACE _—— "8 LADUR STD. iP 2-9 GAGE 8 le" 8'-0' MAX. 2 V4" CLR YP ‘3-"5 CONT. IN CONC. FOOTING / ;— DAL'S TO MATCH (v) WALL REINF RY ALTERNATE BENDS R € FTG ¢ WALL ALTERNATE 1 NOTE: SRRATE POSTING BES DESIGN CRITERIA |, ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF 2. ALLOWABLE LATERAL BEARING PRESSURE = 100 PSF 3. SEISMIC LOAD BASED ON SITE CLASS D w/ MAPPED. SPECTRAL ACCELERATION, 150

You might also like