Type series booklet

2539.561/3--10 Ama® --Porter ICS®


Submersible Motor Pumps

60 Hz

Fields of Application Designation


Ama® --Porter pumps are used for handling all types of dirty Ama® --Porter 5 01 IE
liquids, in intermittent operation, e.g.:
Handling waste water containing long fibres and solid Type series:
substances as well as media containing gas/air. Nominal diameter:
Drainage/water extraction. DN 50 = pump size 5 _ _
DN 65 = pump size 6 _ _
Operating Data Impeller size
Q : up to 40 m3/h, 11 l/s
H up to 17 m IE = single--phase variant with ICSR
Motor rating: ID = three--phase variant with ICSR
1.5 kW max. with three--phase motor
1.1 kW max. with single--phase a.c. motor Motor
Product temperature up to 40° C. Single--phase a.c. motor
For short periods 70°C (3 to 5 min). 220/255 V, max. 255 V -- 60 Hz
Mode of operation: intermittent operation S3 with integrated overload protection.
Three--phase asynchronous motor
Materials 380/440 V, max. 440 V -- 60 Hz,
Casing : Cast iron GG 20 / EN.GJL-200 / JL 1030 / FGL 200. d.o.l. starting; with integrated overload protection.
Impeller : Cast iron GG 20 / EN.GJL-200 / JL 1030 / FGL 200. Motors IP 68, thermal class F to EN 60529 / IEC 529.
Shaft : 1.4021 / X20 Cr13 / Z20 C13.
Please note :
Shaft seal (drive end): lip seal
Variable--speed operation of this pump is not
Shaft seal (pump end): mechanical seal SiC / Al2O3
allowed.
Bolts and nuts : A2
Joint rings : nitrile rubber Operating mode S1 - submerged (max. 5 m)
Operating mode S3 - not submerged
ICS: Polypropylene
(see dimension table)
Design Bearings
Vertical submersible motor pump in close--coupled design.
Grease--lubricated ball bearings sealed for life.
Shaft Seal
Drive end: : 1 shaft seal ring -- EN 12 050
Pump end: : 1 bi--rotational mechanical seal The pump must not be used in countries where pumps
with environment--friendly oil fill handling sewage with faeces are subject to explosion
protection regulations.
Innovation
The Intelligent Control System ICSR ensures automatic
operation of the pump(s) without floats and control panels.
Ama® -Porter ICS®

Scope of Supply Pump Set


Complete unit as portable version or for stationary installation consisting -- Material: Cast iron GG 20 / EN.GJL-200 / JL 1030 / FGL 200.
of pump set and installation kit. -- Non--explosion--proof motor.
-- Absolutely water--tight, resin--embedded cable entry.
-- Single--phase a.c. motor, 10 m cable with UK plug.
Thermal Overload Protection of the
-- Three--phase asynchronous motor, 10 m cable.
Motors -- Installation parts
Single-- phase a.c. -- Protective coating:
Winding is protected by 1 temperature switch Surface treatment: SA 2 1/2 SIS 055900
at 160° C Primer coat: ferritic oxide 35 to 40 mm.
Three-- phase asynchronous motor Top coat : environmentally--friendly KSB--standard coating,
Winding is protected by 2 temperature switches approx.40 μm, RAL 5002 (ultramarine blue).
160 °C as a standard.
PLEASE NOTE: A SWING CHECK VALVE MUST ABSOLUTELY
BE INSTALLED IN THE DISCHARGE LINE.

Installation Kit

Pump size 5 _ _ IE/ID 6_ _ IE/ID


Variant

Portable 3 support feet, made of stainless steel 1.4301 3 support feet, made of stainless steel 1.4301
Connection elbow with internal thread 2” Connection elbow with internal thread 2 1/2 ”
Adapter 2”/63 mm Adapter 2 1/2 ” /80 mm
Hose clip (∅ 60 to 80) Hose clip (∅ 80 to 100)
Bolts and nuts Bolts and nuts

Stationary Duckfoot bend 50/50 mm Duckfoot bend 65/65 mm


Guide rope or rail or hoop Claw Claw
(vertical discharge connection) Bracket Bracket
Guiding rope or hoop Guiding rope or hoop
Rail not included Rail not included
Anchor bolts Anchor bolts
Chain Chain

Stationary Duckfoot bend 50/2” Duckfoot bend 65/2 1/2 ”


Guide rope or rail or hoop Claw Claw
(horizontal discharge connection) Bracket Bracket
Guiding rope or hoop Guiding rope or hoop
Rail not included Rail not included
Anchor bolts Anchor bolts
Chain Chain

Automatic Pump Control by ICS®

Consecutive pumping cycles


For the subsequent pumping cylces, ICS® controls changeover bet-
S3 S3
S2 S2 ween the two pumps.
S1 S1 Every eight cycles, ICS® recalculates the parameters and assigns each
pump an updated operating time so as to optimise operation of the pum-
ping station.
Parallel operation
If the flow into the tank exceeds the discharge capacity of a single pump,
First pumping cycle and level S3 is reached, ICS® starts up the second pump without delay.
As soon as level S2 is reached for the first time, both pumps start and
The second pump is also started up if the water level remains at level S2
operate until the tank has been emptied.
for a prolonged period of time.
At the same time, each pump is assigned a cut--in delay period for the
Both pumps continue to operate until the tank has been emptied.
next start--up.
When the pumps stop, ICS® measures the pumping time required and Prolonged standstill of the unit
calculates the pumping time for the the next cycle. 24 hours after the last pump operation, ICS® automatically starts up
each pump. If any waste water is present, pumping will continue until the
Second pumping cycle tank has been emptied. Otherwise, pump operation will stop again in a
Once level S2 is reached again, the pump with the shorter cut--in delay
fraction of a second.
period is started.
This way ICS® eliminates the risk of clogging and reduces bad odours
Via its ICS®, the pump not in operation recognises that the other pump
to a minimum.
is in operation and cancels its own cut--in delay period.
The pump in operation stops after expiry of its calculated operating
period and is assigned another cut--in delay period.

2 Subject to modifications
Ama® -Porter ICS®

Ama® -Porter ICS Product Features

ICS Dry, pressure--tight and encapsulated


Intelligent Control System submersible squirrel--cage motor.
Thermal class F.
Fast installation and high operating
reliability. Your benefit:
Maximum operating reliability thanks
to optimum motor design

Lateral cable entry to provide


protection.
Your benefit: Temperature is monitored by
Damage during transport and temperature switches in the winding.
installation are prevented.
Your benefit:
Motor damage caused by
overheating is prevented.

Plug--in connection with


polarizing slot.
Your benefit:
Fast servicing without Oversized motor for long operating
the risk of faulty periods.
connection. Your benefit:
Reliable operation under heavy--duty
conditions.

Shaft made of
corrosion--resistant
stainless steel
Your benefit: Automatic, bolt--free
No corrosion problems, connection for
therefore long service life. stationary installation;
leakage prevented by
flexible sealing.
Your benefit:
The most simple and
at the same time most
operator- friendly
Bi--rotational mechanical solution:
seal with SiC/Al2O3- Easy installation and
contact faces. removal of the pump.

Your benefit:
A solution ensuring long
service life. ICS prevents
gluing of the mechanical
seals.

Free flow impeller Wetted bolts made of stainless steel.


Your benefit: Your benefit:
Large passage to accommodate A small detail providing added ease of
coarse particles. service. Easy to dismantle even after
years of operation.

Subject to modifications 3
Ama® -Porter ICS®

Ama® -Porter size 5 _ _ IE/ID 3 500 1/min

Laufradform
Impeller type
Forme de roue
Tipo girante
Tipo de rodete

501 = 45 mm
500 = 45 mm

freier Durchgang
Förderhöhe free passage
Head section de passage
Hauteur passaggio libero
Prevalenza paso libre
Altura
manométrica

Kennlinien nach DIN


1944/III. Sie entspre-
chen der effektiven
Motordrehzahl.

Curves as per DIN


1944/III. They corres-
pond to the effective
motor speed.

Courbes selon DIN


1944/III. Elles corres-
501 pondent à la vitesse
de moteur effective.
500 Curve secondo DIN
1944/III. Correspon-
denti agli effettivi giri
del motore.
m3/h
Curvas según DIN
1944/III. Se refieren a
la velocidad efectiva
del motor.
Förderstrom/Capacity/Débit/Portate/Caudal

60 Hz -- 1~ 220/255V
Pump size Impeller-∅ P1 P2 IN IA Product Power supply Power supply Weight Ident. No.
temp. cable cable
outside diameter
mm kW kW (A) (A) °C mm kg
500 IE [UK] 100 1,9 1,1 8,2 18,2 40 3 x 1 mm2 9,0 22 39 020 162
501 IE [UK] 110 1,9 1,1 8,2 18,2 40 3 x 1 mm2 9,0 22 39 020 163

60 Hz -- 3~ 380/440V
500 ID 100 1,5 1,1 2,8 18,3 40 4 x 1 mm2 10 22 39 020 164
501 ID 110 1,9 1,5 3,5 18,3 40 4 x 1 mm2 10 22 39 020 165
γ=1, Viscosity=1 cSt.

4 Subject to modifications
Ama® -Porter ICS®

Ama® -Porter size 6 _ _ IE/ID 3 500 1/min

Laufradform
Impeller type
Forme de roue
Tipo girante
Tipo de rodete

601 = 60 mm
600 = 60 mm

Förderhöhe
Head freier Durchgang
Hauteur free passage
Prevalenza section de passage
Altura passaggio libero
manométrica paso libre

Kennlinien nach DIN


1944/III. Sie entspre-
chen der effektiven
Motordrehzahl.

Curves as per DIN


1944/III. They corres-
pond to the effective
motor speed.

Courbes selon DIN


1944/III. Elles corres-
pondent à la vitesse
de moteur effective.
601
Curve secondo DIN
600 1944/III. Correspon-
denti agli effettivi giri
del motore.
m3/h
Curvas según DIN
1944/III. Se refieren a
la velocidad efectiva
del motor.
Förderstrom/Capacity/Débit/Portate/Caudal

60 Hz -- 1~ 220/255V
Pump size Impeller-∅ P1 P2 IN IA Product Power supply Power supply Weight Ident. No.
temp. cable cable
outside diameter
mm kW kW (A) (A) °C mm kg
600 IE [UK] 100 1,9 1,1 8,2 18,2 40 3 x 1 mm2 9,0 25 39 020 166
601 IE [UK] 110 1,9 1,1 8,2 18,2 40 3 x 1 mm2 9,0 25 39 020 167
60 Hz -- 3~ 380/440V
600 ID 100 1,5 1,1 2,8 18,3 40 4 x 1 mm2 10 25 39 020 168
601 ID 110 1,9 1,5 3,5 18,3 40 4 x 1 mm2 10 25 39 020 169
γ=1, Viscosity=1 cSt.

Subject to modifications 5
Ama® -Porter ICS®

Dimensions
Ama® -Porter ICS® size 5 _ _ Transportable version

Swing check valve


required

For flexible hose


inner diameter
Ø 63 mm

(1) lowest switch off level

Ama® -Porter ICS® size 6 _ _ Transportable version

Swing check valve


required

For flexible hose


inner diameter
Ø 80 mm

(1) lowest switch off level

6 Subject to modifications
Ama® -Porter ICS®

Dimensions
Ama® -Porter ICS® size 5 _ _
Vertical flange discharge DN 50/50
Stationary version with guide wire lifting system
Stationary version with guide hoop

Guide hoop

Swing check
valve required

ISO 7005 PN 16
DN 50 PN 16
ASME 2”

Flange of duckfoot
bend
(1) lowest switch off level

Ama® -Porter ICS® size 6 _ _


Vertical flange discharge DN 65/65
Stationary version with guide wire lifting system
Stationary version with guide hoop

Guide hoop

Swing check
valve required

ISO 7005 PN 16
DN 65 PN 16
ASME 2”1/2

Flange of duckfoot
bend
(1) lowest switch off level

Subject to modifications 7
Ama® -Porter ICS®

Dimensions
Ama® - Porter ICS® size 5 _ _
Vertical flange discharge DN 50/50
Stationary version with guide rail lifting system
1 Rail

Pipe Ø 33.7 x 3.2

Swing check
valve required

ISO 7005 PN 16
DN 50 PN 16
ANSI 2”

Flange of duckfoot
bend

(1) lowest switch off level

Ama® -Porter ICS® size 6 _ _


Vertical flange discharge DN 65/65
Stationary version with guide rail lifting system
1 Rail

Pipe Ø 33.7 x 3.2

Swing check
valve required

ISO 7005 PN 16
DN 65 PN 16
ASME 2”1/2

Flange of duckfoot
bend

(1) lowest switch off level

8 Subject to modifications
Ama® -Porter ICS®

Dimensions
Ama® -Porter ICS® size 5 _ _
Horizontal pedestal installation G 2”
Stationary version with guide wire lifting system
Stationary version with guide hoop

Guide hoop

Swing check
valve required

(1) lowest switch off level

Ama® -Porter ICS® size 6 _ _


Horizontal pedestal installation G 2” 1/2
Stationary version with guide wire lifting system
Stationary version with guide hoop

Guide hoop

Swing check
valve required

(1) lowest switch off level

Subject to modifications 9
Ama® -Porter ICS®

Dimensions
Ama® -Porter ICS® size 5 _ _
Horizontal pedestal installation G 2”
Stationary version with guide rail lifting system
1 Rail

Pipe Ø 33.7 x 3.2

Swing check
valve required

(1) lowest switch off level

Ama® -Porter ICS® size 6 _ _


Horizontal pedestal installation G 2” 1/2
Stationary version with guide rail lifting system
1 Rail

Pipe Ø 33.7 x 3.2

Swing check
valve required

(1) lowest switch off level

10 Subject to modifications
Ama® -Porter ICS®

Installation in a sump
Recommended dimensions

Max. 10 mm
Swing check valve Swing check valve Swing check valve
required required required

On

200
D E
mini
Off
C

A x A min. >F

B min.

Single pumping station Dual pumping station

Dimensions in mm
AxA C D E AxB C D E F
Ama--Porter 5 _ _ ICS 600 x 600 65 300 450 Ama--Porter 5 _ _ ICS 600 x 750 65 300 450 300

Ama--Porter 6 _ _ ICS 600 x 600 70 306 480 Ama--Porter 6 _ _ ICS 600 x 750 70 306 480 350

Subject to modifications 11
Ama® - Porter ICS®

Display Module (Option)


Display module for single--phase a.c.; Ident--No 39 019 940
operating status is not transmitted.

The data of our equipment are only given for information


Voltage 230 V, 1 phase + earthed conductor. Indicator lamps indicating:
Frequency 50/60 Hz, max. -- Full load white
Current intensity 10 A. -- Pump is available yellow
Temperature --10 °C to +50 °C. -- Pump is in operation green
Type of enclosure IP 43. -- Fault P1 red

and can be modified without notice.


CEE plug and socket. -- Fault of partner orange

Dimension : 105 x 60 x 90

Display module for single--phase a.c.; Ident--No 39 020 214


operating status is transmitted
Voltage 230 V, 1 phase + earthed conductor. Indicator lamps indicating:
Frequency 50/60 Hz. -- Full load white
Max. current intensity 10 A. -- Pump is available yellow
Temperature --10 °C to +50 °C. -- Pump is in operation green
Type of enclosure: IP 54. -- Fault P1 red
-- Fault of partner orange
Dimension : 166 x 90 x 56
-- Reset

Display module for three--phase current.; Ident--No 39 019 941


operating status is transmitted
Voltage 400 V, 3 phases+earthed conductor. Indicator lamps indicating:
Frequency 50/60 Hz. -- Full load white
Max. current intensity 5 A. -- Pump is available yellow
Temperature --10 °C to +50 °C. -- Pump is in operation green
Type of enclosure IP 54. -- Fault P1 red
-- Fault of partner orange
Dimension : 166 x 90 x 56
-- Reset

Display module for single--phase a.c.; Ident--No 39 020 692


with transmission of the operating status of 2 pumps
Voltage 230 V, 1 phase + earthed conductor. Indicator lamps indicating:
Frequency 50/60 Hz, max. -- Full load white
Current intensity 10 A per pump. -- Pump 1/pump 2 is available yellow
Temperature --10 °C to +50 °C. -- Pump 1/pump 2 is in operation green
Type of enclosure IP 54. -- Fault P1 red
10A fuses integrated. -- Fault P2 red
On/Off switch.
1~ 230 V -- Reset
Dimensions : 185 x 147 x 77

Display module for three--phase current; Ident--No 39 020 693


with transmission of the operating status of 2 pumps
Voltage 400 V, 3 phases + earthed conductor. Indicator lamps indicating:
09/2008

Frequency 50/60 Hz. -- Full load white


Max. current intensity 5 A per pump. -- Pump 1/pump 2 is available yellow
Temperature --10 °C to +50 °C. -- Pump 1/pump 2 is in operation green
Type of enclosure IP 54. -- Fault P1 red
6A fuses integrated. -- Fault P2 red
On/Off switch.
3~ 400 V -- Reset
2539.561/3--10

Dimensions : 185 x 147 x 77

An additional system must be provided to ensure overflow protection (e.g. AS 0 + float switch).

KSB S.A.S.
128, rue Carnot -- F--59320 Sequedin (Lille) D Phone : +33 3 20 22 70 00
B.P. 60095 -- F--59482 Haubourdin Cedex D Fax : +33 3 20 22 71 47 D http://www.ksb.com