Professional Documents
Culture Documents
1 Motor provided by
2 Motor mounted by
3 No. of turbines required
4 Turbine item no.
5 No. of stages Turbine provided by
6 No. of motors required Turbine mounted by
7 Motor item no. Remarks:
8 Notes: O indicates information to be completed by Purchaser. o indicates information to be completed by Manufacturer.
9
10 OPERATING CONDITIONS (to be completed by purchaser)
11 Liquid NPSH available (m):
12 Pumping temperature (°C) PT Rated Maximum Minimum
13 Normal Maximum Minimum Capacity @ PT (m3/h):
14 Specific gravity @ PT Rated Maximum Minimum
15 Vapor pressure @ PT (bar) Discharge pressure (bar g):
16 Viscosity @ PT Rated Maximum Minimum
17 cP Differential pressure (bar)
18 Site temperature (°C) : Rated Maximum Minimum
19 Normal Maximum Minimum Differential head (m):
20 Electrical area hazard: Rated Maximum Minimum
21 Zone Temp. class Hyd. power (kW) Rated Max. Min.
22 Unusual conditions Location O Indoor O With Roof O Heated
23 O Outdoor O Without Roof O Unheated
24 Corrosion/erosion caused by Remark:
25
26 PERFORMANCE (to be completed by manufacturer)
27 Proposal curve No. Minimum continuous flow (m3/h)
28 Speed (rpm) Thermal Stable
29 NPSH required (m MLC). Driver rating (kW)
30 3 % Head drop at rated flow Shaft thrust (kN) Max.
31 Rated power (kW)
32 Maximum kW with rated impeller Rotation (viewed from coupling end): O CW O CCW
33 Maximum head with rated impeller (m) Suction specific speed
34 Max. continuous flow m3/h Efficiency (%) at rated flow
35 NOTES:
36
37
38
39
40
41
NORSOK CENTRIFUGAL PUMP RDS-001
R-001 DATA SHEET Rev. 1, Dec. 1994
Page 2 of 5
43 Casing mount: o Centerline o Near centre-line Lubrication type: o Oil mist o Ring oil o Pressure
44 o Foot o Vertical o In-line o Flinger o Flood o CLO
45 o Bracket o Vertical barrel o Sump pump Coupling:
46 Casing split: o Axial o Radial o Shaft diameter (mm)
47 Casing type: o Volute o Single o Staggered o Manufacturer
48 o Diffuser o Double o Type
49 o Max. allowable casing pressure: o Model
50 bar g @ 15 °C bar g @ PT o Service factor:
51 o Hydrostatic test pressure : bar g Driver half-coupling mounted by:
52 o Casing design pressure : barg at °C O Pump manufacturer O Driver manufacturer O Purchaser
53 NOZZLES SIZE RATING FACING LOCATION Gland plate taps required:
54 Suction O Quench O Flush O Drain O Vent
55 Discharge Coupling guard(s)
56 Miscellaneous connections o Manufacturer
57 o Material
58 o Nonsparking type
59 Mounting plate :
60 O Baseplate O Skidplate O Soleplate
61 Manufactured by:
62 Bearings /type no. O Pump manufacturer O Driver manufacturer O Purchaser
63 o Radial Thrust O Standard O Heavy duty
64 Impeller diameter (mm) Open beam support
65 o Rated o Max. o Min. O Fully grouted O Ungrouted
66 Impeller mount o Between bearings o Overhung o Overall size (m)
67 o Moment of inertia J (kg m²) Remarks:
68 Packing:
69 o Manufacturer
70 o Type
71 o Size/no. of rings
72 Mechanical seal:
73 o Manufacturer
74 o Model
75 o Manufacturer code
76 o API class code
77 o Gland type/material
78 O Dimension standard
79
80
81 AUXILIARY PIPING (to be completed by purchaser and manufacturer)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T