750-585, 750-586
4 2-Channel Analog Output Module 0-20 mA, Ex i
364
13 14 15 16
Function AO 1 Function AO 2
A1 A2 Data contacts
AO 1
AO 2
— —
0V
S S
Shield
Shield
(screen) 750-585 (screen)
Power jumper contacts
Delivered without miniature WSB markers
The analog output modules transmits intrinsically safe 0/4 - 20mA signals in the Note: The analog output module must only be operated via Ex i 24VDC power
hazardous Zone 0+1. supply!
The WAGO-I/O-SYSTEM 750 must be installed either in Zone 2 or in a
non-hazardous area. General information (e.g., installation regulations) on explosion protection is
Power is derived from the power jumper contacts. available in the WAGO-I/O-SYSTEM 750 manuals!
The outputs are short-circuit proof.
LED displays:
• Green LED (output status)
Pack.
Description Item No.
Unit Technical Data
2AO 0-20mA Ex i 750-585 1 No. of outputs 2
2AO 4-20 mA Ex i 750-586 1 Current consumption, system voltage typ.
(5 VDC) 21 mA
Voltage via power jumper contacts 24 V DC (provided via Ex-i supply
UO = max. 27.3 V)
Signal current 0 ... 20 mA (750-585)
4 mA ... 20 mA (750-586)
Load impedance < 500 Ω
Linearity ± 2 LSB
Resolution 12 bits
Conversion time < 2 ms
Output error 25 °C < ± 0.2 % of the full scale value
Pack. Temperature coefficient < ± 0.01 % / K of the full scale value
Accessories Item No.
Unit Current consumption, power jumper
Miniature WSB Quick marking system contact typ. (24 VDC) 19 mA + load (2 x 20 mA)
plain 248-501 5 Power consumption Pmax. 1.5 W
with marking see Section 11 Power loss PV 0.9 W
Isolation UM = 375 V system/supply
Bit width 2 x 16 bits data
WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 - D-32385 Minden Tel.: +49(0)571/887-0 E-Mail: info@wago.com
Subject to design changes 27.07.2017 Hansastr. 27 - D-32423 Minden Fax: +49(0)571/887-169 www.wago.com
4
365
1 5 9 13
I A Logic
AO 1/AO 2 AO U D
Function
2 6 10 14
24 V 24 V 4.9
10 nF
3 7 11 15
0V
0V
0V 4.7 nF
4 8 12 16
Shield Shield
(screen) (screen)
750-585
1)
Does not apply to 750-586