You are on page 1of 1

REVIEW STATUS

APPROVED APPROVED REJECTED FOR


AS NOTED INFORMATION
BY BZ BAA BBB BCC
DATE REVIEWED
5590 9000 9000 9000 9000 625

REVIEWED BY
DATE REVIEWED

REVIEWED BY

Key Plan LEVEL-03


N

Center line of door

Center line of door

Center line of door

Center line of door


BU BV BW BX BY BZ BAA BBB BCC BDD BEE BFF BGG

BHH BJJ

B16

B17

NIC

420

420

423

430
B18

D
C
FT
D

FT
D
FT
D

D
FT
D

FT
D
H

C
D

G
H

C
D
FT
D

H
D

G
FT
D

H
D

G
D

C
D

H
FT
D

G
FT

C
FT
D

D
H
D

H
D
2966 1200 1200 1200 1200 1200 1200

C
D
H

C
H

D
C

D
H
C

D
C

C
D
FT
D

H
D
D

H
C
905

905

905

905

905

905
FT
D

FT
D

FT
D
FT
D

C
D

C
H
H

C
D

D
H

H
D
C
D

D
H

H
H
D

H
D

C
D

H
C H

FT
D
C
C

FT
D

FT
D
D

D
C

H
Cr
D

FT
D

D
C

FT
D

D
C
Cs

H
Cs
Cr
D

C
H
D

H
D

C
D
RC15 RC15 RC15

FT
D
1230

1230

1230
RC15

FT
D

C
H
C
D
H

HATCH
375
B19

D
D

FT
D
D

G
D
C
1980 1980

G
G
2220 2372

H
G
1952

1952

1952

1952
3390

H
D

D
C
H
C
D
H

C
325

325

325
D

C
D
H
D

D
H
C C

D
H

FT
D
HATCH

D
H
C

C
D
FT
D

C
D
H
B20

C
D

H
D
C

FT
D
H

P1-20

P1-18

P1-16

P1-14

P1-12

P1-10

P1-08

P1-06

P1-04

P1-02

P3-01

P3-03

P3-05

P3-07

P3-09
P1-19

P1-17

P1-15

P1-13

P1-11

P1-09

P1-07

P1-05

P1-03

P1-01

P3-02

P3-04

P3-06

P3-08

P3-10
NIC NIC

974 420 420 378 494 1068 997 1995 771 579 650 708 270 1080 933 675 538 378 1830 327 595 1800 600 997 481 516 445 1675 1005 1005 670 575 547 448 375 1467 381 547 821 632 740 477 2258 448 852 2140 473 600 283 317 547 565 340 633

C
FT

D
H
Sky Hook Typ. Sky Hook Typ. Sky Hook Typ.

H
D
C
FT
D

H
D
H
D
C

C
FT
D

E2 E2 E2 E2 E2 E2 E2 E2 E2

117
B21

Center line of door

H
FT
D

D
C
SH SH SH SH SH SH SH SH SH

D
OS CD OS CD OS CD OS CD OS CD OS CD

H
C
RI RI RI RI RI RI RI H

D
C

FT
D

C
D

H
D
D
C

FT
D

H
D

D
H

RC15

C
C

D
C

H
H C H

D
C

C
D
FT
D

FT
D
GN1/1

FT
D

FT
D

D
H
D

C
GN1/1

GN1/1

HATCH
D

H
RC15

D
GN1/1

FT
D

FT
D
FT
D

C
D
D

H
D

H
C H H C

H
D

D
A1

FT
D
D

H
FT
D

200 200 200 200 200 200

FT
D
H
D

H
D

200
C

C
C
D
H

C
D

1850 5750 5780


B22

A1
D D

920

920

920

920

920

Cr

C
Cs D

NIC

1341
200
1296

200
437

437

437

437
B23
DM6C DM6C DM6C DM6C DM6C DM6C DM6C DM6C DM6C
RC14 RC15 RC14 RC15 RC14 RC15
200 200 200

OS 1700 1719 1510 1510 1710 1000 710 1701 1710 1510 1510 1723 987 710 1710 1710 1510 1510 1710 1710
OS
NOTES:

1150

1150

1150
200 200 200

1350

1350

1350

1350

1350

1350
THIS DRAWING IS BASED ON THE INFORMATION RECEIVED

924
852

FROM THE CLIENT AND ACCORDING TO OUR


Equal CD Equal Equal CD Equal INTERPRETATION OF THE CONCEPT DRAWINGS, SKETCHES
RC14 RC14 RC14 RC14 RC14 RC14
AND SPECIFICATIONS.
HD C

681

680
FDT

3500

3500
400

793

400

400

790

400

400

790

400
''IF THERE ARE ANY CHANGES/ DEVIATIONS OR
RC15 RC15 RC15 RC15 RC15 RC15
INSTRUCTIONS THAT MAY INCUR ADDITIONAL COST, WE

500
500

5030

RC15 RESERVE OUR RIGHT TO RE-EVALUATE AND FORWARD

1350

1350

1350

1350

1350

1350
VARIATIONS.''

DO NOT SCALE FROM THIS DRAWING. WORK FROM

200

200

200
200

200

200
FIGURED DIMENSIONS

200

200

200
200

200

200
2700

2700

2700
RI DM6C
RC14 RC15
DM6C DM6C CS DM6C DM6C
RC14 RC15
DM6C CS DM6C DM6C
RC14 RC15
DM6C RI
ANY DISCREPANCIES TO BE VERIFIED PRIOR TO
MANUFACTURE

3061
3054
14272

75 419 494 722 1710 250 630 630 400 630 630 250 250 1460 650 1060 533 363 394 419 1710 250 630 630 400 645 615 250 1710 650 1060 535 347 393 427 1578 142 250 630 630 400 630 630 250 1710 555 483 595 75
ANY ELEMENT INDICATED "BY OTHERS" IS SHOWN ONLY AS
1350

1350

1350

1350

1350

1350
INDICATIVE. FOR EXACT DETAILS FOR THESE ITEMS. REFER
TO RESPECTIVE DRAWINGS.

13017
AP-2
250

RC14 RC14 RC14 RC14 RC14 RC14

CURRENT DRAWING IS FOR INTERIOR DESIGN ONLY FOR

3500

3500
400

790

400

400

790

400

400

790

400
BA-LT-409 ANY FURTHER DETAIL OF OTHER TRADES. KINDLY REFER TO
Suspended Lamp RC15
RC15 RC15 RC15 RC15 RC15 RC15
RESPECTIVE DRAWINGS.
BA-LT-409
CURRENT DRAWING HAS BEEN COORDINATED WITH THE
1034

1027
HD C

1350

1350

1350

1350

1350

1350
Equal Equal
Suspended Lamp INTERPHASING TRADES PRIOR SUBMISSION.
1018 1031
988

200

200

200
Equal Equal
E2 E2 E2 E2 E2 E2 E2 E2 E2
ALL DIMENSIONS SHOULD BE VERIFIED

200

200

200
2700

2790

2790
2700
DM6C OS CD DM6C CD DM6C OS SH DM6C OS CD DM6C CD DM6C OS SH DM6C OS CD DM6C DM6C
SH ON SITE PRIOR TO PROD'N. OR INSTALLATION

1027
RC14 RC15 RC14 RC15 RC14 RC15

ALL DIM. IN MILLIMETERS (MM) UNLESS


533 533 635 445 370 904 250 630 630 400 630 630 250 570 570 570 445 256 765 523 535 535 639 415 390 906 250 630 630 400 630 630 250 1282 428 738 850 523 OTHERWISE SPECIFIED.
494 494 714 425 400 893 250 630 630 400 629 631 250 570 570 570 425 409 753 523 1029
2150

1000
1350

1350

1350

1350

1350

1350
FDT

Reference Drawing / Name Drawing Number Rev.

621
H

(L)7500x(W)180 CUT-OUT
FOR PROJECTOR SCREEN RC14 RC14 RC14 RC14 RC14 RC14
OS
L03 HT Ballroom construction plan DMCC-1-WBD-PA-DR-ID-A4.1.03 BA 00

579
D
H

17025

17025
7340

3500

3500
400

790

400

400

790

400

400

790

400
624

AP-1
RC15
Related Drawings / Name Drawing Number Rev.
DC

RC15 RC15 RC15 RC15 RC15 RC15

622
A1
775 350
1375 764 130 551 Podium L03 block work masonry plan zone-3 DUT-3IM-SHD-ARC-PD-L03-13003 02
C

CD
1350

1350

1350

1350

1350

1350
1241
1230

FDT

578
2150

Podium L03 block work masonry plan zone-4 DUT-3IM-SHD-ARC-PD-L03-13004 02


180
200

200

200

200

200

200
L04 (Podium P4) chilled water layout sheet-4 DUT-VBJ-SHD-CHW-PD-L04-13073 01
200

200

200
200

200

200
2700

2700

2700

873
RI DM6C
W RC14 RC15
DM6C DM6C RI SH DM6C RI
W RC14 RC15
DM6C DM6C RI SH DM6C RI
W RC14 RC15
DM6C DM6C
SH
A1
1686 815 345 451 523
A1 A1 L04 (Podium P4) chilled water layout sheet-4 DUT-VBJ-SHD-CHW-PD-L04-13074 01
1066 300 340 1399 315 250 388 466 405 400 630 630 250 1069 300 332 1403 315 250 406 466 388 400 630 630 250 1725 512 482 579 523
75 912 300 414 1719 250 427 466 367 400 629 631 450 1910 650 428 509 523
Wall paint finish @ operable partition room RTQ-1#223
B21 B21
1350

1350

1350

1350

1350

1350
1406

1406

1406

1020
1066

level-03 (podium-03) cctv system overall


BA-LT-409 DUT-VBJ-SHD-CTV-PD-L03-18060 02
RC15
layout
RC14 RC14 RC14 RC14 RC14 RC14

Suspended Lamp Related RFIs / Name Drawing Number Rev.

3500

3500
400

400

400

400

400

400
790

790

790

600
AP-1 AP-1 AP-1
Ceiling Access Panel Requirements,
250

RC15 RC15 RC15 212 RC15 RC15 212 RC15


AP-2
212
Locations and Sizes (Pending RFI)
130

130

130
BA-LT-409 A1 A1 A1
1350

1350

1350

1350

1350

1350
624 200 624 200 624 200
Suspended Lamp
764

764

764

3036
Level 03 Ballroom Meeting Room Area Retractable
3054

DUT-BSX-RFI-INT-PD-L03-01310 00
200

200

200
1018 1029
Projector & Screen Details Required
200

200

200
E2 E2 E2 E2 E2 E2 E2 E2 E2
200

200

200
2700

2700

2700
DM6C OS CD DM6C DM6C DM6C CD DM6C DM6C DM6C OS CD DM6C DM6C
HD C

RC14 RC15 RC14 RC15 RC14 RC15


FDT

533 533 636 814 904 250 420 420 420 400 630 630 250 1140 570 650 1060 494 576 639 415 390 764 142 250 420 420 420 400 630 630 250 1140 585 535 1160
494 494 722 425 400 893 250 420 420 420 400 629 631 450 450 890 570 650 1060
1350

1350

1350

1350

1350

1350
917
5030

RC15

565
500

RC14 RC14 RC14 RC14 RC14 RC14


3500

3500
400

400

400

400

400

400
790

790
9151

9151
820

820
RC15 RC15 RC15 RC15 RC15 RC15

Equal OS Equal Equal OS Equal


1350

1150

1350

1350

1350

1350
200 200 200
670

1150

1150

1150

740
200
75 612 1023 1710 1510 1510 1710 744 976 860 850 1275 435 1510 1510 1710 1132 586 835 875 1299 418 7435 1510 1510 1710 527 571 612
CD 200 200 200
CD
BIM FEDERATED MODEL REFERENCE:
DUT-DED-MOD-BIM-NA-ALL-00000_20210210_Published_R89
437

437

437

437
RI DM6C DM6C DM6C RI DM6C RI DM6C DM6C RI DM6C RI DM6C DM6C RI
RC14 RC15 RC14 RC15 RC14 RC15
1465

1395
A1 A1
989

990
635 340 420 640 1618 3091 772 579 1362 400 664 811 1337 379 1470 600 670 1550 600 997 995 447 1174 1001 1067 660 565 376 1467 383 546 810 703 1157 2735 451 850 2240 412 600 587 613 470 340 633
Sky Hook Typ. Sky Hook Typ. Sky Hook Typ. Sky Hook Typ. Sky Hook Typ. Sky Hook Typ. Sky Hook Typ.
E2 E2 E2 E2 E2 E2 E2 E2 E2
Sky Hook Typ.
RC15
SH 7340 SH OS CD SH SH OS CD SH OS CD SH SH OS CD SH OS CD SH
3500 5840 7340 5843 7340 3548
2655 5405 5040 2230 5670 5800 1720 5625 5253 1532
350

350

350
2745 2880
AP-1 AP-1 AP-1 AP-1 AP-1 AP-1
180 180 180 180 180
180
325

325

325
2250 2180 1400
2250 700
2250 3210

1882
1880

1880
3772 1465
657
1311

1311

1311
1230

1230

1230
3210 1465 3795 3406
975

975

975

975

975
905

905

905

905

905

905
RC15 RC15 RC15 RC15 RC15 RC15
1200 1200 1200 1200 1200 1200
Rev. Date Description Drn. Ckd. Apd.
395

395

395
420
Center line of door

Center line of door

Center line of door

Center line of door

Center line of door

Center line of door


Employer:
DUBAI MULTI COMMODITIES CENTRE
H C HD C
HD C H Almas Tower

6
D CD
Jumeirah LAkes Towers
Dubai,United Arab
Emirates

FDT
L03-02201
FDT Project Manager:
FT
D

TURNER INTERNATIONAL MIDDLE EAST


P.O. Box 13036, Dubai, UAE
NOT III SCOPE OF WORK BOH SERVICE T: +971 4 337 0990 | F: +971 4 334 8216
Gulf Towers Bldg., A2 Block, 8th Floor
L03.041 Oud Metha Rd., Dubai, UAE
www.turnerconstruction.com/international

5590 9000 9000 9000 9000


Consultant / Architect of Record: WSP Middle East
REF: RB-06 Architectural & Engineering
Consultancy
(L)7500x(W)180 CUT-OUT (L)7500x(W)180 CUT-OUT (L)7500x(W)180 CUT-OUT P.O Box: 7497, Dubai U.A.E
BY BZ BAA BBB LINEAR LED STRIP IN BCC Tel: +971 4 523 1999 | Fax: +971 4 523 1998

FOR PROJECTOR SCREEN FOR PROJECTOR SCREEN FOR PROJECTOR SCREEN www.wsp.com
CEILING COVE -20W/m 27th Flr. Office Suite 2703A&B
U-Bora Tower, Al Abraj St. Business Bay
Dubai,United Arab Emirates

* BALLROOM REFLECTED CEILING PLAN ACESS PANEL LEGEND AIR RETURN GAP REFER TO DRAWING
Main Contractor:
L03-02203 SCALE 1:75M DUT-III-SHD-INT-PD-LO3-02202 SPOT
DETAIL 7
SYMBOL DESCRIPTION
AP-1 ACESS PANEL DOOR 600X600mm SYMBOLS DESCRIPTION Sub Contractor:
MEP LEGEND
AP-1 ACESS PANEL DOOR 300X300mm SYMBOLS DESCRIPTION W WIRELESS ACESS POINT

E2 RETRACTABLE PROJECTOR
EMERGENCY LIGHT SCREEN
CCTV LEGEND
CONCEALED PENDENT ANTENNA Project Name:
SPRINKLER AV
SYMBOL DESCRIPTION
Jumeriah Lake Tower, Free Zone
CD CEILING VA SPEAKER DUAL CHANNEL DANTE RECIVER Dubai, United Arab Emirates
FIXED DOME WALL MOUNTED CAMERA
WITH BRACKET WiFi Drawing Title
OS SMOKE DETECTOR WIFI ACCESS POINT

LIGHT LEGEND:
LEVEL0
-3
RI REMOTE INDICATOR GSM ANTENNA
BALLROOM
SYMBOL DESCRIPTION DM6C CIELING SPEAKER (BOSE DM6C) AC SUPPLY
MEP&LG
IHTN
IGPLAN
(RB06) LINEAR LED STRIP IN CEILING COVE -20W/m CIELING SUBWOOFER AIR RETURN GAP
Drawn by: Checked by: Approved by:
(RC14) CEILING RECESSED ADJUSTABLE DOWNLIGHT SH SKY HOOK VJ PV
US
FOR VANITY DALI, 20W
Scale Sheet Size Sheet
NOTE : NUMBER OF SKY HOOKS STILL UNDER APPROVAL
(RC15) CEILING RECESSED ADJUSTABLE DOWNLIGHT
FOR VANITY DALI, 20W As Shown A1 - of -
Drawing Number Revision.
DUT-III-SHD-INT-PD-L03-02203 01
TC