s4891 ee, ISOLAB ‘a Excellence In Calibration CERTIFICATE OF CALIBRATION No: CS191042 Date of Issue: 13" March 2019 Issue By: ISOLAB (SINGAPORE) PTE LTD. Requested by : Barghest Building Performance Pte Ltd 150 Cantonment Road, #01-06 ‘Singapore 089762 Acez Sensing Job No E9472 Job Order No 190421 Ambient Temperature (22£2)°C Relative Humidity (55 10) % Relative Humidity _ Page 2 10f3 Descriptions Instrument 10K Thermistors Brand AS Model NIA Serial No EP 108209 Immersion 200 mm Calibration Range 0.01°C to 29.765°C Calibration Start Date 11" March 2019 Calibration End Date 11" March 2019 Isolab (S) Pte Ltd and its practices are in compliance with ISO/IEC 17025: 2005. The Quality System practice is in accordance with the Quality Standard ISO 9001. Method of Calibration The 10K Thermistor has been calibrated at ISOLAB’s laboratory under the ambient conditions stated above according to in-house calibration procedure STCP-003-R4 and STCP-016-R3. The references used are traceable to national measurement standards maintained at National Metrology Centre (NMC-Singapore), National Physical Laboratory (NPL-UK) and Norther Temperature Primary Laboratory (NTPL, UKAS). The calibration was performed in accordance to International Temperature Scale of 1990 (ITS-90). Reference Standards used for Calibration: SIN: Reference Standards Serial No. Reference ReportNo: Next Calibration Due Date 1, Reference Sensor 36981/2 C118083-S 20" August 2019 2. Reference Sensor 3648222 C118081-S, 20" August 2019 3. Reference Indicator My44037443 EL006857 26% July 2019 4, Reference Indicator 09-P123 2910921 18-08-41 14” August 2019 5. Gallium Melting Point Cell GASOS 12-03-50 12" March, 2022 Calibrated By, Approved By: GeralhQaek ‘Simon Montero Calibration Officer Approved Signatory herein have been performed in accordance with the laboratory's terms naan the i “creditation ColifQWAB (Singapore) Pte Ltd javenerataces cous) (OSAPE iyi greprndostomhcrhasigdplexaggowith prior written approval of ISOLAB, TERENEEIND Tel (5) 62666155 Fax: (65) 62666824 mall servicealsoabcomsg_ wwwislabcomsg 3 ee CERTIFICATE OF CALIBRATION No: CS191042 | | 10K Thermistor | Serial Number: EP 108209 | , S Page 2 20f3 Calibration Start Date ; 12" March 2019 Calibration End Date : 12"March 2019 Results of Calibration ‘The results of the calibration are shown in the table below. The expanded uncertainty is at a level of confidence of approximately 95% with a coverage factor. Calibration And Measurement Capability (CMC*): (1) Gallium Melting Point 2) @0°C 0 30°C: 0.011°C (29.7646°C) : 0.003°C Calibration Results (As Found) ‘Actual Temperature TOK Thermistor Uncertainty ieFactor co) Indicated Values (kO) (CormK) 0.01 32.6083 13 mK 2.00 15.00 15,6982 13 mK 2.00 29.765 832 3 mK 2.00, * “The results reported herein have been performed in accordance with the laboraiory's terms of accrediation ‘under the Singapore Accreditation Council”. Remarks The interpolation Equation for the “Thermistor” is: 1 =A+B(LnR)+C(LnR)* T Where; T = Temperature in Kelvin Rx Resistance values in Ohms at Temperature t InR, = Natural logarithm of Resistance values in Ohms [A.B. C, Coefficients Derived From Measurement _| A 1.129531E-03 B= | 2.340803E-04 C= | 8.795314E-08 ———————— CERTIFICATE OF CALIBRATION No: CS191042 10K Thermistor Serial Number: EP 108209 Page 30f3 | Calibration Start Date: 12" March 2019 Calibration End Date 12 March 2019 Appendix ‘Temperature Resistance Table for 10K Thermistors ‘Temperature | Resistance | Temperature | Resistance Value (Q) eo) Value (0) 0 32621.6178 16 14989.0342 i 31003.2270 7 14313.2192 2 729474,4540 18 13671.6435 3 28029.8580 19 13062.3961 4 26664.3559 20 12483.6819 3 25373.1970 21 11933.8143 6 ___24151.9399 22 11411.2078 7 22996.4304 23 109143719 8 21902.7820 24 10441,9044 9 20867.3574 25 992.4865 10 19886,7509 26 9564.8768 i 18957.7730 27 9157.9068 2 18077.4355 28 870.4761 B 17242,9380 29 84015482 4 16451.6547 30 | 8050.1464 15 15701.1234 = - Calibrgtfon Offer

You might also like