You are on page 1of 153

HP 3PAR StoreServ 7000/7450 Storage

Cabling Configuration Guide C:


2 Node Systems with Mixed-Size Drive Enclosures

Abstract
This guide provides cabling information for authorized technicians performing installation and maintenance services on the HP
3PAR StoreServ 7000/7450 Storage systems.

HP Part Number: QR482-96506


Published: August 2013
Edition: 1
© Copyright 2013 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Acknowledgments

Microsoft®, Windows®, are U.S. registered trademarks of Microsoft Corporation.


Warranty
WARRANTY STATEMENT: To obtain a copy of the warranty for this product, see the warranty information website:

http://www.hp.com/go/storagewarranty

Printed in the US.


Contents
1 Cabling Preparation for HP 3PAR StoreServ 7000/7450.................................6
Following Precautions................................................................................................................6
Identifying and Labeling the Components....................................................................................6
2 Cabling HP 3PAR StoreServ 7000/7450.......................................................9
2 Node 2 Drive Enclosures (1S+1L).............................................................................................9
Attach DP-1 Chains to Enclosures..........................................................................................10
Attach DP-2 Chains to Enclosures.........................................................................................11
Review Completed Cabling.................................................................................................12
2 Node 3 Drive Enclosures (1S+2L)...........................................................................................13
Attach DP-1 Chains to Enclosures..........................................................................................14
Attach DP-2 Chains to Enclosures.........................................................................................15
Review Completed Cabling.................................................................................................16
2 Node 3 Drive Enclosures (2S+1L)..........................................................................................17
Attach DP-1 Chains to Enclosures..........................................................................................46
Attach DP-2 Chains to Enclosures.........................................................................................47
Review Completed Cabling.................................................................................................48
2 Node 4 Drive Enclosures (1S+3L)...........................................................................................21
Attach DP-1 Chains to Enclosures..........................................................................................46
Attach DP-2 Chains to Enclosures.........................................................................................47
Review Completed Cabling.................................................................................................48
2 Node 4 Drive Enclosures (2S+2L)..........................................................................................25
Attach DP-1 Chains to Enclosures..........................................................................................46
Attach DP-2 Chains to Enclosures.........................................................................................47
Review Completed Cabling.................................................................................................48
2 Node 4 Drive Enclosures (3S+1L)..........................................................................................29
Attach DP-1 Chains to Enclosures..........................................................................................46
Attach DP-2 Chains to Enclosures.........................................................................................47
Review Completed Cabling.................................................................................................48
2 Node 5 Drive Enclosures (1S+4L)...........................................................................................33
Attach DP-1 Chains to Enclosures..........................................................................................34
Attach DP-2 Chains to Enclosures.........................................................................................35
Review Completed Cabling.................................................................................................36
2 Node 5 Drive Enclosures (2S+3L)..........................................................................................37
Attach DP-1 Chains to Enclosures..........................................................................................38
Attach DP-2 Chains to Enclosures.........................................................................................39
Review Completed Cabling.................................................................................................40
2 Node 5 Drive Enclosures (3S+2L)..........................................................................................41
Attach DP-1 Chains to Enclosures..........................................................................................42
Attach DP-2 Chains to Enclosures.........................................................................................43
Review Completed Cabling.................................................................................................44
2 Node 5 Drive Enclosures (4S+1L)..........................................................................................45
Attach DP-1 Chains to Enclosures..........................................................................................46
Attach DP-2 Chains to Enclosures.........................................................................................47
Review Completed Cabling.................................................................................................48
2 Node 6 Drive Enclosures (1S+5L)...........................................................................................49
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 6 Drive Enclosures (2S+4L)..........................................................................................53
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151

Contents 3
Review Completed Cabling...............................................................................................152
2 Node 6 Drive Enclosures (3S+3L)..........................................................................................57
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 6 Drive Enclosures (4S+2L)..........................................................................................61
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 6 Drive Enclosures (5S+1L)..........................................................................................65
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 7 Drive Enclosures (1S+6L)...........................................................................................69
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 7 Drive Enclosures (2S+5L)..........................................................................................73
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 7 Drive Enclosures (3S+4L)..........................................................................................77
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 7 Drive Enclosures (4S+3L)..........................................................................................81
Attach DP-1 Chains to Enclosures..........................................................................................82
Attach DP-2 Chains to Enclosures.........................................................................................83
Review Completed Cabling.................................................................................................84
2 Node 7 Drive Enclosures (5S+2L)..........................................................................................85
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 7 Drive Enclosures (6S+1L)..........................................................................................89
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 8 Drive Enclosures (1S+7L)...........................................................................................93
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 8 Drive Enclosures (2S+6L)..........................................................................................97
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 8 Drive Enclosures (3S+5L)........................................................................................101
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 8 Drive Enclosures (4S+4L)........................................................................................105
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 8 Drive Enclosures (5S+3L)........................................................................................109
Attach DP-1 Chains to Enclosures........................................................................................150

4 Contents
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 8 Drive Enclosures (6S+2L)........................................................................................113
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 8 Drive Enclosures (7S+1L)........................................................................................117
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 9 Drive Enclosures (1S+8L).........................................................................................121
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 9 Drive Enclosures (2S+7L)........................................................................................125
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 9 Drive Enclosures (3S+6L)........................................................................................129
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 9 Drive Enclosures (4S+5L)........................................................................................133
Attach DP-1 Chains to Enclosures........................................................................................134
Attach DP-2 Chains to Enclosures.......................................................................................135
Review Completed Cabling...............................................................................................136
2 Node 9 Drive Enclosures (5S+4L)........................................................................................137
Attach DP-1 Chains to Enclosures........................................................................................138
Attach DP-2 Chains to Enclosures.......................................................................................139
Review Completed Cabling...............................................................................................140
2 Node 9 Drive Enclosures (6S+3L)........................................................................................141
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 9 Drive Enclosures (7S+2L)........................................................................................145
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
2 Node 9 Drive Enclosures (8S+1L)........................................................................................149
Attach DP-1 Chains to Enclosures........................................................................................150
Attach DP-2 Chains to Enclosures.......................................................................................151
Review Completed Cabling...............................................................................................152
3 Additional Resources and Related Documentation.......................................153
Contacting HP......................................................................................................................153
HP 3PAR Documentation........................................................................................................153

Contents 5
1 Cabling Preparation for HP 3PAR StoreServ 7000/7450
The following instructions list important precautions and information about cabling installation
options for the HP StoreServ Storage system.

Following Precautions
Follow these general precautions to avoid injury, data loss, and damage before and during
installation or while servicing the HP 3PAR StoreServ Storage system:
• Avoid using improper tools
• Prepare an Electrostatic Discharge-safe (ESD) work surface by placing an antistatic mat on
the floor, or table, near the storage system. Attach the ground lead of the mat to an unpainted
surface of the rack
• Always use a wrist-grounding strap, provided with the storage system. Attach the grounding
strap clip directly to an unpainted surface of the rack
• Avoid contact between electronic components and clothing which can carry an electrostatic
charge
• Ensure all cables are properly labeled and easily identifiable prior to removing a component
• Observe local occupational safety requirements and guidelines for handling heavy equipment
• Always load the heaviest item first, and start from the bottom when loading the rack. Loading
from the bottom makes the rack bottom-heavy and helps prevent the rack from becoming
unstable
• Do not attempt to move a fully-loaded equipment rack. Remove all equipment from the rack
before moving the rack
• Use at least two people to safely move the rack from the pallet

Identifying and Labeling the Components


This section of the chapter applies to all configurations in this guide. The guide provides instructional
guidance for cabling the HP 3PAR StoreServ 7000/7450 according to a specific configuration.
All HP 3PAR StoreServ Storage systems contain either the HP 3PAR 7200 (2 nodes) or 7400/7450
(with 2 or 4 nodes), M6720 large drive enclosure(s), and M6710 small drive enclosure(s).
The M6720 large drive enclosures supports 3.5-inch disk drives and the smaller M6710 drive
enclosure supports 2.5-inch disk drives.
The cabling configurations are identifiable by the specific number of nodes connecting to a
combination of small or large disk drive enclosures. The cabling configuration examples below
uses the following identification:
• 2 Node 10 Drive Enclosure (1S) refers to a configuration using two nodes connecting to one
small (2.5-inch) disk drive enclosure
• 2 Node 10 Drive Enclosures (6S+4L) refers to a configuration using two nodes connecting to
a combination of six small (2.5-inch) and four large (3.5-inch) drive enclosures

6 Cabling Preparation for HP 3PAR StoreServ 7000/7450


Types of Components
Use the red and green color coding to assist with the cabling. Only connect to components sharing
the same color.

Figure 1 Identifying Components and SAS Ports

Identifying and Labeling the Components 7


Labeling the Enclosures
Before connecting the cables:
• Labels (A, B, C, and D) are provided to help identify the enclosures in the storage system.
Apply the labels to each enclosure in a visible location and avoid covering other labels
• Apply label A to the controller enclosure with nodes 0 and 1. Alternate the labeling (A/B) on
each enclosure below the controller enclosure
If applicable, a system using four nodes, apply label C to the controller enclosure with nodes 2
and 3. Alternate the labeling (C/D) on each enclosure above the controller enclosure.
The illustration below describes a typical configuration using two nodes and a combination of
large and small drive enclosures.

NOTE: The illustrative depiction may not reflect the configuration setup of your system but the
labeling pattern is similar.

Figure 2 Labeling the Enclosures

For more information relating to cabling hosts, refer to HP 3PAR StoreServ 7000/7450 Installation
Guide.

8 Cabling Preparation for HP 3PAR StoreServ 7000/7450


2 Cabling HP 3PAR StoreServ 7000/7450
The following illustrative sections provide a rear view of the rack with recommended racking
configuration of the system.

2 Node 2 Drive Enclosures (1S+1L)


Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 2 Drive Enclosures (1S+1L) 9


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

10 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 2 Drive Enclosures (1S+1L) 11


Review Completed Cabling

12 Cabling HP 3PAR StoreServ 7000/7450


2 Node 3 Drive Enclosures (1S+2L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 3 Drive Enclosures (1S+2L) 13


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

14 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 3 Drive Enclosures (1S+2L) 15


Review Completed Cabling

16 Cabling HP 3PAR StoreServ 7000/7450


2 Node 3 Drive Enclosures (2S+1L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 3 Drive Enclosures (2S+1L) 17


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

18 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 3 Drive Enclosures (2S+1L) 19


Review Completed Cabling

20 Cabling HP 3PAR StoreServ 7000/7450


2 Node 4 Drive Enclosures (1S+3L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 4 Drive Enclosures (1S+3L) 21


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

22 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 4 Drive Enclosures (1S+3L) 23


Review Completed Cabling

24 Cabling HP 3PAR StoreServ 7000/7450


2 Node 4 Drive Enclosures (2S+2L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 4 Drive Enclosures (2S+2L) 25


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

26 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 4 Drive Enclosures (2S+2L) 27


Review Completed Cabling

28 Cabling HP 3PAR StoreServ 7000/7450


2 Node 4 Drive Enclosures (3S+1L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 4 Drive Enclosures (3S+1L) 29


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

30 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 4 Drive Enclosures (3S+1L) 31


Review Completed Cabling

32 Cabling HP 3PAR StoreServ 7000/7450


2 Node 5 Drive Enclosures (1S+4L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 5 Drive Enclosures (1S+4L) 33


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

34 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 5 Drive Enclosures (1S+4L) 35


Review Completed Cabling

36 Cabling HP 3PAR StoreServ 7000/7450


2 Node 5 Drive Enclosures (2S+3L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 5 Drive Enclosures (2S+3L) 37


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

38 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 5 Drive Enclosures (2S+3L) 39


Review Completed Cabling

40 Cabling HP 3PAR StoreServ 7000/7450


2 Node 5 Drive Enclosures (3S+2L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 5 Drive Enclosures (3S+2L) 41


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

42 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 5 Drive Enclosures (3S+2L) 43


Review Completed Cabling

44 Cabling HP 3PAR StoreServ 7000/7450


2 Node 5 Drive Enclosures (4S+1L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 5 Drive Enclosures (4S+1L) 45


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

46 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 5 Drive Enclosures (4S+1L) 47


Review Completed Cabling

48 Cabling HP 3PAR StoreServ 7000/7450


2 Node 6 Drive Enclosures (1S+5L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 6 Drive Enclosures (1S+5L) 49


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

50 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 6 Drive Enclosures (1S+5L) 51


Review Completed Cabling

52 Cabling HP 3PAR StoreServ 7000/7450


2 Node 6 Drive Enclosures (2S+4L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 6 Drive Enclosures (2S+4L) 53


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

54 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 6 Drive Enclosures (2S+4L) 55


Review Completed Cabling

56 Cabling HP 3PAR StoreServ 7000/7450


2 Node 6 Drive Enclosures (3S+3L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 6 Drive Enclosures (3S+3L) 57


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

58 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 6 Drive Enclosures (3S+3L) 59


Review Completed Cabling

60 Cabling HP 3PAR StoreServ 7000/7450


2 Node 6 Drive Enclosures (4S+2L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 6 Drive Enclosures (4S+2L) 61


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

62 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 6 Drive Enclosures (4S+2L) 63


Review Completed Cabling

64 Cabling HP 3PAR StoreServ 7000/7450


2 Node 6 Drive Enclosures (5S+1L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 6 Drive Enclosures (5S+1L) 65


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

66 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 6 Drive Enclosures (5S+1L) 67


Review Completed Cabling

68 Cabling HP 3PAR StoreServ 7000/7450


2 Node 7 Drive Enclosures (1S+6L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 7 Drive Enclosures (1S+6L) 69


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

70 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 7 Drive Enclosures (1S+6L) 71


Review Completed Cabling

72 Cabling HP 3PAR StoreServ 7000/7450


2 Node 7 Drive Enclosures (2S+5L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 7 Drive Enclosures (2S+5L) 73


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

74 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 7 Drive Enclosures (2S+5L) 75


Review Completed Cabling

76 Cabling HP 3PAR StoreServ 7000/7450


2 Node 7 Drive Enclosures (3S+4L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 7 Drive Enclosures (3S+4L) 77


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

78 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 7 Drive Enclosures (3S+4L) 79


Review Completed Cabling

80 Cabling HP 3PAR StoreServ 7000/7450


2 Node 7 Drive Enclosures (4S+3L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 7 Drive Enclosures (4S+3L) 81


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

82 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 7 Drive Enclosures (4S+3L) 83


Review Completed Cabling

84 Cabling HP 3PAR StoreServ 7000/7450


2 Node 7 Drive Enclosures (5S+2L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 7 Drive Enclosures (5S+2L) 85


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

86 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 7 Drive Enclosures (5S+2L) 87


Review Completed Cabling

88 Cabling HP 3PAR StoreServ 7000/7450


2 Node 7 Drive Enclosures (6S+1L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 7 Drive Enclosures (6S+1L) 89


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

90 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 7 Drive Enclosures (6S+1L) 91


Review Completed Cabling

92 Cabling HP 3PAR StoreServ 7000/7450


2 Node 8 Drive Enclosures (1S+7L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 8 Drive Enclosures (1S+7L) 93


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

94 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 8 Drive Enclosures (1S+7L) 95


Review Completed Cabling

96 Cabling HP 3PAR StoreServ 7000/7450


2 Node 8 Drive Enclosures (2S+6L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 8 Drive Enclosures (2S+6L) 97


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

98 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 8 Drive Enclosures (2S+6L) 99


Review Completed Cabling

100 Cabling HP 3PAR StoreServ 7000/7450


2 Node 8 Drive Enclosures (3S+5L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 8 Drive Enclosures (3S+5L) 101


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

102 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 8 Drive Enclosures (3S+5L) 103


Review Completed Cabling

104 Cabling HP 3PAR StoreServ 7000/7450


2 Node 8 Drive Enclosures (4S+4L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 8 Drive Enclosures (4S+4L) 105


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

106 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 8 Drive Enclosures (4S+4L) 107


Review Completed Cabling

108 Cabling HP 3PAR StoreServ 7000/7450


2 Node 8 Drive Enclosures (5S+3L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 8 Drive Enclosures (5S+3L) 109


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

110 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 8 Drive Enclosures (5S+3L) 111


Review Completed Cabling

112 Cabling HP 3PAR StoreServ 7000/7450


2 Node 8 Drive Enclosures (6S+2L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 8 Drive Enclosures (6S+2L) 113


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

114 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 8 Drive Enclosures (6S+2L) 115


Review Completed Cabling

116 Cabling HP 3PAR StoreServ 7000/7450


2 Node 8 Drive Enclosures (7S+1L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 8 Drive Enclosures (7S+1L) 117


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

118 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 8 Drive Enclosures (7S+1L) 119


Review Completed Cabling

120 Cabling HP 3PAR StoreServ 7000/7450


2 Node 9 Drive Enclosures (1S+8L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 9 Drive Enclosures (1S+8L) 121


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

122 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 9 Drive Enclosures (1S+8L) 123


Review Completed Cabling

124 Cabling HP 3PAR StoreServ 7000/7450


2 Node 9 Drive Enclosures (2S+7L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 9 Drive Enclosures (2S+7L) 125


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

126 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 9 Drive Enclosures (2S+7L) 127


Review Completed Cabling

128 Cabling HP 3PAR StoreServ 7000/7450


2 Node 9 Drive Enclosures (3S+6L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 9 Drive Enclosures (3S+6L) 129


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

130 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 9 Drive Enclosures (3S+6L) 131


Review Completed Cabling

132 Cabling HP 3PAR StoreServ 7000/7450


2 Node 9 Drive Enclosures (4S+5L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 9 Drive Enclosures (4S+5L) 133


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

134 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all AB drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 9 Drive Enclosures (4S+5L) 135


Review Completed Cabling

136 Cabling HP 3PAR StoreServ 7000/7450


2 Node 9 Drive Enclosures (5S+4L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 9 Drive Enclosures (5S+4L) 137


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

138 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 9 Drive Enclosures (5S+4L) 139


Review Completed Cabling

140 Cabling HP 3PAR StoreServ 7000/7450


2 Node 9 Drive Enclosures (6S+3L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 9 Drive Enclosures (6S+3L) 141


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

142 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 9 Drive Enclosures (6S+3L) 143


Review Completed Cabling

144 Cabling HP 3PAR StoreServ 7000/7450


2 Node 9 Drive Enclosures (7S+2L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 9 Drive Enclosures (7S+2L) 145


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

146 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 9 Drive Enclosures (7S+2L) 147


Review Completed Cabling

148 Cabling HP 3PAR StoreServ 7000/7450


2 Node 9 Drive Enclosures (8S+1L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2, “Identifying and Labeling the Components” (page 6).

2 Node 9 Drive Enclosures (8S+1L) 149


Attach DP-1 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
2. Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

150 Cabling HP 3PAR StoreServ 7000/7450


Attach DP-2 Chains to Enclosures
Red routing
1. Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.

Green routing
1. Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
2. Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.

NOTE: The two adjacent enclosures are not directly connected.

2 Node 9 Drive Enclosures (8S+1L) 151


Review Completed Cabling

152 Cabling HP 3PAR StoreServ 7000/7450


3 Additional Resources and Related Documentation
Contacting HP
For worldwide technical support information, see the HP support website:
http://www.hp.com/support

Before contacting HP, collect the following information:


• Product model names and numbers
• Technical support registration number (if applicable)
• Product serial numbers
• Error messages
• Operating system type and revision level
• Detailed questions
Specify the type of support you are requesting:

HP 3PAR Storage System Support Request

HP 3PAR StoreServ 7200, 7400, and 7450 Storage StoreServ 7000/7450 Storage
systems

HP 3PAR StoreServ 10000 Storage systems 3PAR or 3PAR Storage


HP 3PAR T-Class storage systems
HP 3PAR F-Class storage systems

HP 3PAR Documentation
For additional information about other related cabling configurations, refer to the following
documents:
• HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide A: 2 Node Systems
with Small 2.5-inch Drive Enclosures
• HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide B: 2 Node Systems
with Large 3.5-inch Drive Enclosures
• HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide C: 2 Node Systems
with Mixed-Size Drive Enclosures
• HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide D: 4 Node Systems
with Small 2.5-inch Drive Enclosures
• HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide E: 4 Node Systems
with Large 3.5-inch Drive Enclosures
• HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide F: 4 Node Systems
with Mixed-Size Drive Enclosures