You are on page 1of 5

http://www.osram.

com

Product data sheet:


OPTOTRONIC OT 100/240/700 P5 IN
Constant Current LED Power supply
OPTOTRONIC constant current Power Supply with high reliability is best choice for outdoor application.
Drivers fits in Street lighting, high bay & flood lighting indoor & outdoor application.

Picture Product Features


Output currents 700mA
Output voltage 115Vdc – 144 Vdc
Output Power 80.5 W – 100 W
Type Suitable for class I and II luminaires
Protection 6KV surge, 440 VAC
Lifetime Upto 100’000 hrs
Applications Street, high bay & Flood lights
Approval marks BIS
EAN 10 4062172150378
EAN 40 4062172150385

Benefits
6/6 KV Surge & 440 Vac Protection
Input Overvoltage Protection
Input Undervoltage Protection
Over Temperature Protection
IP65
OT 100 PICTORIAL REPRESENTATION. EMI & EMC Complaint
Long lasting and high reliability

DIMENSIONS
L 167 mm
B 60 mm
H 37.5 mm
Weight 700 gm
Case Material Metal

15 July 2020 p 1/5


Electrical Specifications.

Input
Item Value Unit Remarks
Nominal Voltage 240 Vac
Nominal frequency 50 Hz
AC voltage range 204 – 276 Vac Safety Voltage Range
DC voltage range NA V
Maximum operational voltage 100 - 320 V
Nominal current 600 mA Full load, 230 V, 50 Hz
Total Harmonic Distortion (THD) < 10 % Full load, 230 V, 50 Hz
Power factor 0.99 Full load, 230 V, 50 Hz
Efficiency 92 % Full load, 230 V, 50 Hz
No-load power <3 W Open Load, 230 V, 50 Hz
Power loss 9.2 W At 230V, Pin Max 34.4W
Protection class I
Inrush current <32 A twidth =230µs typical (measured at 50% Ipeak)
Max unit per circuit breaker B16: 20; B10: 13
Touch current < 0.5 mA Output Floating

Output
Nominal voltage range 115 - 144 Vdc
Maximum voltage 250 Vdc Open Circuit
Nominal current range 700 mA
Current accuracy +/- 5 %
Current ripple <5 % Ripple @ 100 Hz
Nominal power range 80.5 – 100.8 W
Maximum power 100 W
Galvanic isolation 3000 V Output to mains – leakage current < 2mA

Dim
Dimming control Na
Dimming range Na %
Dimming technique Na
Frequency Na Hz
Galvanic isolation Na

Environment
Ambient temperature range ta -20 …+ 60 °C
Max case temperature tc 85 °C
Max case temp. in fault condition 110 °C
Storage temperature range -20 …+75 °C
Relative humidity 5 ... 90 %
Surge transient protection 6 kV
Environmental rating Outdoor Potted
IP rating IP 65
Mains switching cycles > 100’000
Expected lifetime 50’000 h At Tc
100’000 h At Tc – 10 C
Protections
Surge 6/6 KV L-N / L-N/PE
Input overvoltage Auto cut-off above 325
Vac, Reversible
Input Undervoltage Auto cut-off below 100 Current reduces below 140 Vac
Vac, Reversible
Over Temperature Thermal Foldback 20̊C above Tc power reduce by more than 15%; Refer Graph
Output Overvoltage Yes, Uout < 150 V
No load Yes
440 Vac Survival of unit for 48 Hrs
Short-circuit Yes, Reversible

Wiring Diagram
Terminal Wire
Max. cable length 2m
Geometry lxbxh 167 X 60 X 37.5 mm
Weight 700 gm

Rated output and current sets


I out (mA) 700
U min (V) 115
U max (V) 144
P min (W) 80.5
P max (W) 100
Ta (°C) 60
Tc (°C) 85
Line current, nominal @230 V (mA) 600
Max power loss @230 V (W) 9.2
Input power @230 V (W) 110

Standards
Safety IS 15885 -2-13, IEC 61347-2-13
Performance IS 16104, IEC 61547, IEC 61000-3-2
CISPR 15/ EN55015, IEC 61000-3-3

Graphs
Remarks

• Input over voltage protection: Driver goes into shutdown mode above 325V input voltage & automatic restart below
325 V input Voltage.
• Input over Voltage (320Vac @ 50C ambient): Driver will survive higher mains input up to 48hrs at 320 Vac. It will not
destroy both the unit (Driver and load).
• Phase to Phase Voltage (440Vac @ 35C ambient): Driver will survive higher mains input up to 48hrs at 440 Vac. It
will not destroy both the unit and load; shut down of load will occur in this condition.
• EMI/EMC – Driver comply with EMI/EMC standards.
• Input Under Voltage: Output current will decrease when input voltage go below 140+/-10V. Hence input power also
get reduced which improves product reliability. When input voltage goes below 110V, then driver will not shut down.
Driver will survive up to 48hrs at 100V @50C ambient.
• Output short circuit protection: short circuit current is limited to approx. Iav 0.2 A without damage to the unit, for
unlimited time. Be sure the load wire is designed to withstand the short circuit current as well.
• Output over voltage protection: shut down of load happens if Uout exceeds 144V; mains switchover is not needed to
restart the unit.
• Output under voltage operation: the unit is not damaged if the load voltage is lower than 115 V. The load may go
into hic-up mode for unlimited time. Some of the operational parameters may not met. Please make sure to replace
with suitable load.
• No load operation: The unit is not damaged in this condition; the output wattage is lower than 2Wand output voltage
is limited to Uout 250 V. Mains switchover is not needed to restart the unit after load connection if mains is already on.
• Thermal Protection: The output current of driver will decrease if the Tc is increases 15 deg.C of the declared Tc.
• Over temperature Operation: It is not recommended to operate the device above Tc temperature limit.
If tc exceed 110°C approx. the load will shut down; The protection is automatically reversible when temperature comes
down. Between Tc 70 – 110C driver will not go into shutdown.
• Output power hold time: < 1s, in case of mains dips.
• HOT Plug: connection of LED on output is allowed without damage of LED.

OSRAM LIGHTING PVT.LTD.


1st Floor, IFFCO Surinder Jhakhar Bhavan,
Plot No. - 3, Sector-32,
Gurgaon-122001, Haryana, India
www.osram.com

Technical Customer support:

Toll free number: 18004190426


Annexure A
SPD Installation

1. It is better to connect the SPD at the Minimum distance to the Led driver.
2. OSRAM SPD /approved SPD recommended for better compatibility & protection.
3. SPD should be connected in series with the Driver as per the wiring diagram below:

Figure 1 : SPD Wiring diagram

OSRAM LIGHTING PVT.LTD.


1st Floor, IFFCO Surinder Jhakhar Bhavan,
Plot No. - 3, Sector-32,
Gurgaon-122001, Haryana, India
www.osram.com

Technical Customer support:

Toll free number: 18004190426

You might also like