30 Testing and adjusting SEN00229-03

Adjustment (Pump Absorption Torque (F)) 3. Selecting absorption torque


The operator can adjust various items related to the After the "Pump Absorption Torque (F)" screen
machine with the machine monitor. is displayed, select a set value on the right side
The pump absorption torque (F) function is used to with the function switches.
finely adjust the absorption torque on the front side q Set value: For actual torque adjustment
of the hydraulic pump. value, see table
q [F3]: Increase set value
1. Selecting menu q [F4]: Decrease set value
Select “Adjustment” on the “Service Menu” screen. q [F6]: Confirm setting and return to Adjust-
ment menu screen
a The 3 digits on the left side do not vary
since they are the code of this function.

2. Selecting sub menu


After the “Adjustment” screen is displayed,
select “Pump Absorption Torque (F)” with the
function switches or numeral input switches. a Relationship between set value and
a Select this item similarly to an item on the torque adjustment value
“Service Menu” screen. Set
Code Torque adjustment value
value
000 +39.2 Nm {+4 kgm}
001 +29.4 Nm {+3 kgm}
002 +19.6 Nm {+2 kgm}
003 +9.8 Nm {+1 kgm}
021 004 0 Nm {0 kgm}
005 –9.8 Nm {–1 kgm}
006 –19.6 Nm {–2 kgm}
007 –29.4 Nm {–3 kgm}
008 –39.2 Nm {–4 kgm}

PC200, 220-8 45
SEN00229-03 30 Testing and adjusting

Adjustment (Pump Absorption Torque (R)) 3. Selecting absorption torque


The operator can adjust various items related to the After the "Pump Absorption Torque (R)" screen
machine with the machine monitor. is displayed, select a set value on the right side
The pump absorption torque (R) function is used to with the function switches.
finely adjust the absorption torque on the rear side q Set value: For actual torque adjustment
of the hydraulic pump. value, see table
q [F3]: Increase set value
1. Selecting menu q [F4]: Decrease set value
Select “Adjustment” on the “Service Menu” screen. q [F6]: Confirm setting and return to Adjust-
ment menu screen
a The 3 digits on the left side do not vary
since they are the code of this function.

2. Selecting sub menu


After the “Adjustment” screen is displayed,
select “Pump Absorption Torque (R)” with the
function switches or numeral input switches. a Relationship between set value and torque
a Select this item similarly to an item on the adjustment value
“Service Menu” screen. Set
Code Torque adjustment value
value
000 +39.2 Nm {+4 kgm}
001 +29.4 Nm {+3 kgm}
002 +19.6 Nm {+2 kgm}
003 +9.8 Nm {+1 kgm}
022 004 0 Nm {0 kgm}
005 –9.8 Nm {–1 kgm}
006 –19.6 Nm {–2 kgm}
007 –29.4 Nm {–3 kgm}
008 –39.2 Nm {–4 kgm}

46 PC200, 220-8
30 Testing and adjusting SEN00229-03

Adjustment (Low speed) 3. Selecting travel Low speed


The operator can adjust various items related to the After the "Low Speed" setting screen is dis-
machine with the machine monitor. played, select a set value on the right side with
The travel Low speed setting function is used to the function switches.
finely adjust the travel Low speed. q Set value: For actual travel Low speed
value, see table
1. Selecting menu q [F3]: Increase set value
Select “Adjustment” on the “Service Menu” screen. q [F4]: Decrease set value
q [F6]: Confirm setting and return to Adjust-
ment menu screen
a The 3 digits on the left side do not vary
since they are the code of this function.

2. Selecting sub menu


After the “Adjustment” screen is displayed,
select “Low speed” with the function switches
or numeral input switches.
a Select this item similarly to an item on the a Relationship between set value and travel
“Service Menu” screen. Low speed value
Set
Code Travel Low speed value
value
000 3.0 km/h
001 2.8 km/h
020
002 3.2 km/h
003 3.4 km/h

PC200, 220-8 47
SEN00229-03 30 Testing and adjusting

Adjustment (Attachment Flow Adjustment) 3. Selecting distribution of oil flow


The operator can adjust various items related to the After the screen of "Attachment Flow Adjust-
machine with the machine monitor. ment" is displayed, select a set value on the
The function of "Attachment Flow Adjustment" is right side with the function switches.
used to finely adjust the oil flow to the attachment in q Set value: For actual distribution of flow,
compound operation. see table
1. Selecting menu q [F3]: Increase set value
Select “Adjustment” on the “Service Menu” q [F4]: Decrease set value
screen. q [F6]: Confirm setting and return to Adjust-
ment menu screen
a The 3 digits on the left side do not vary
since they are the code of this function.

2. Selecting sub menu


After the “Adjustment” screen is displayed,
select “Attachment Flow Adjustment” with the
function switches or numeral input switches. a Relationship between set value and distri-
a Select this item similarly to an item on the bution of flow to attachment
“Service Menu” screen. Set Distribution of flow to
Code
value attachment
000 50 %
001 70 %
044
002 100 %
003 40 %

48 PC200, 220-8