SIMATIC Panels have been proving their value in many dif- SIMATIC HMI Key Panels – The innovative operator
ferent applications in all industrial sectors for many years panels
now. Their innovative power is undiminished here. The
most recent example of this are the SIMATIC HMI Comfort They are pre-assembled and ready-to-install. In this way,
Panels for demanding visualization tasks. These new oper- time-consuming individual assembly and wiring, as re-
ator panels do not only have an innovative design and quired for conventional operator panels, is not necessary.
provide high performance. The configuration via SIMATIC Compared to conventional wiring, this results in time
WinCC V11 is unique. The software is part of the new savings of up to 60%.
Engineering Framework “Totally Integrated Automation
Portal” and provides previously unheard of energy Mobile operator control and monitoring – wireless and
efficiency. with complete safety functionality
Integrated functionality across all display sizes For plants that are very extensive or are difficult to observe
visually, portable operator panels bring important advan-
The portfolio of the SIMATIC Panels is clearly structured: tages: The commissioning engineers, machine operators
Two families of devices cover the majority of HMI applica- or service employees are able to work exactly where they
tions: have the best view of the workpiece or process.
■ SIMATIC HMI Basic Panels are suitable for simple HMI SIMATIC HMI Mobile Panels can be wired or wireless. Com-
applications. plete safety functionality via IWLAN, which was previously
■ SIMATIC HMI Comfort Panels are suitable for complex only available for SIMATIC HMI Mobile Panels.
applications.
Unique energy efficiency
The functionality of the hardware is identical within a
family of devices. You select the optimal display size for SIMATIC Panels can be intuitively configured with SIMATIC
your application and decide whether to operate it via WinCC V11. Increased energy efficiency can be achieved by
touch screen and/or keys. integrating WinCC V11 into the Totally Integrated Automa-
The software is scalable for optimally adapting your HMI tion Portal, the shared Engineering Framework for Totally
or SCADA solution to your respective automation task. Integrated Automation, if additional Totally Integrated
This has the advantage that you can start out small but Automation components such as SIMATIC Controllers are
are able to increase the number of tags, for example, at used. The perfect interaction with STEP 7 prevents multiple
any time and without problems. entries and guarantees consistent data management at
all times.
SIMATIC HMI Key Panels SIMATIC HMI Basic Panels SIMATIC HMI Comfort Panels SIMATIC HMI Mobile Panels
The innovative operator For simple HMI For demanding HMI For maximum mobility
panels applications applications
from page 12 from page 13 from page 15 from page 17
2 SIMATIC Panels
© Siemens AG 2011
Contents
Customized Automation . . . . . . . . . . . . . . . . . . . . 22
SIMATIC Panels 3
© Siemens AG 2011
4 Totally Integrated
System features Automation
© Siemens AG 2011
To be able to respond to the increasing international SIMATIC: more efficient and systematic automation
competitive pressure, it is more important than ever to
consistently make full use of the potential for optimiza- SIMATIC, a core component of Totally Integrated Auto-
tion – over the complete lifecycle of a machine or mation, includes a variety of standardized, flexible, and
plant. scalable products – such as SIMATIC Panels presented
in this brochure.
Optimized processes reduce the total cost of owner-
ship, shorten the time to market, and improve quality. SIMATIC is currently considered to be the global num-
This perfect balance between quality, time, and costs is ber one in automation. One of the decisive reasons for
now, more than ever, the decisive success factor in in- this is that SIMATIC exhibits the six system features of
dustry. Totally Integrated Automation:
• Engineering
Totally Integrated Automation is optimally aligned to all • Communication
requirements and open for international standards and • Diagnostics
third-party systems. With its six characteristic system • Safety
features, Totally Integrated Automation supports the • Security
complete lifecycle of a machine or plant. The complete • Robustness
system architecture offers holistic solutions for every
automation segment on the basis of a comprehensive In addition, SIMATIC features two additional system
range of products. features:
• Technology
• High availability
You can find more about the system features and the
resulting advantages in the following chapter “System
features“.
System
Totally Integrated features
Automation 5
© Siemens AG 2011
System features
With SIMATIC you rely on an integrated engineering environment. Efficient software supports
you over the complete lifecycle of your machine or plant – from the planning and design stages
through configuring and programming as far as commissioning, operation and upgrading.
With its integration capability and harmonized interfaces, SIMATIC software supports a high
degree of data consistency – throughout the entire engineering process.
Siemens has redefined engineering with its Totally Integrated Automation Portal (TIA Portal).
The new TIA Portal engineering framework combines the SIMATIC STEP 7, SIMATIC WinCC and
SINAMICS StartDrive automation software tools in a unique development environment.
Minimization of downtimes –
through efficient diagnostic concepts
Diagnostics
All SIMATIC products feature integrated diagnostic functions with which a fault can be
identified and eliminated to provide increased system availability.
Even with larger plants, the Maintenance Station provides you with a uniform view of
the maintenance-relevant information of all automation components.
6 System features
© Siemens AG 2011
Security
are gaining in importance in industry. For comprehensive protection of a plant, a variety of
suitable measures must be implemented. These range from the company organization and its
guidelines regarding protective measures for PC and control systems through to protection of
automation cells by segmenting the network. Siemens follows the cell protection concept
and, with the modules of the SCALANCE series and the Security modules, offers components
for building up protected cells.
www.siemens.com/industrialsecurity
Robustness
robustness and is perfect for use in industrial environments. Specific system tests ensure
the planned and required quality. SIMATIC components meet all relevant international
standards and are certified accordingly. Temperature and shock resistance are defined in
the SIMATIC quality guidelines, as are vibration resistance or electromagnetic compatibility.
For demanding to extreme rated conditions, special versions such as SIPLUS extreme or
special versions of SIMATIC ET200 are available. These include an increased degree of
protection, extended temperature ranges, and exceptional environmental stress.
Technology
Counting and measuring, cam control, closed-loop control, or motion control: You can
integrate technological tasks in many different combinations and with various degrees of
complexity without a system changeover into the world of SIMATIC – easily, conveniently,
consistently. Parameter assignment and programming are implemented in the familiar
STEP 7 environment.
Maximum availability –
High availability
www.siemens.com/simatic-system-features
System features 7
© Siemens AG 2011
If you are looking for exactly the right operator panel for your
application, we recommend you use the SIMATIC HMI selec-
tion guide.
You can find it at: www.siemens.com/simatic-hmi
with the most up-to-date product range.
Start screen with clear operator prompting Shared user interface for WinCC and STEP 7
Communication options
The connection to the controller is made via PROFINET.
A 2-port Ethernet switch permits the configuration of linear
and ring topologies.
Fail-safe versions
With the help of the integrated PROFIsafe communication, the
KP8F and the KP32F can be used for fail-safe operation with
SIMATIC S7-300F/400F for simple emergency stop applica-
tions. The two additional fail-safe, 24 V-capable digital inputs
of the KP8F can be used for sensors with isolated contacts,
e.g. an SIL 3 emergency stop button.
The KP32F has 4 fail-safe, 24 V-capable digital inputs for sen-
sors with isolated contacts. SIMATIC HMI IPC477C PRO with KP8
The 4", 6" and 10" devices have touch screens and additional,
freely configurable control keys.
The KP300 Basic mono PN rounds off the portfolio of the Basic
Panels at the lower end with a 3" display.
As standard, Basic Panels communicate over PROFINET. The 6" Fast and intuitive process control via keys
and 10" devices are also available as a PROFIBUS version. If a small display is sufficient and the process is only to be con-
trolled via keys, the KP300 Basic mono PN is the perfect
A large number of drivers support the communication with choice.
controllers from other manufacturers.
In addition to a high-resolution monochrome 3" display, it has
Upgradability is ensured 10 freely configurable function keys.
The keypad with the design of a mobile telephone keypad al-
Projects that were created with WinCC V11 for a Basic Panel lows intuitive and fast entry of numbers and words.
can easily be transferred to a higher-performance Comfort
Panel, Mobile Panel or PC. Thus, you can continue to use and The color of the backlight is freely selectable
supplement existing projects after an upgrade. The choices for the color of the LED backlight are white, green,
red, and yellow.
Perfect interaction with SIMATIC S7-1200
The colors can be assigned to individual alarms. This KP300
Basic Panels can be used in a variety of ways. An especially Basic can thus also be used as an alternative to an alarm indi-
high added value results from the visualization of applications cator lamp.
of a modular compact S7-1200 controller. The new SIMATIC
STEP 7 Basic engineering system automatically includes
WinCC Basic V11 in its scope of delivery.
100 percent data security in the event of a power failure Suitable for harsh environments
The integrated protection against voltage failure of the SIMATIC HMI Comfort Panels are robust and have several ap-
Comfort Panels cost-effectively safeguards all data in the provals for international usage and for use in sectors with in-
event of a power failure – no additional uninterruptible creased requirements.
power supply is required. It is also guaranteed for recipes
and archives in RDB format if they are stored on a SIMATIC HMI As standard, the Comfort Panels feature durable aluminum
Memory Card. die-cast fronts starting with the 7-inch model. They are certi-
fied according to ATEX for Ex zones 2 and 22 and can therefore
Wide range of communication options be used in hazardous areas. Marine approvals will be available
soon for all Comfort Panels.
Integrated interfaces
SIMATIC HMI Comfort Panels are suitable for integration into Ergonomic key operation
PROFINET and PROFIBUS networks and they offer interfaces
for connecting USB peripherals. The intuitive operator control of the key devices corresponds
to that of the tried and tested mobile telephone keypads and
A 2-port Ethernet switch is available for devices with 7" displays permits easy, quick entries. All function keys are equipped
or larger. For devices with 15" displays or larger, a Gigabit with LEDs.
PROFINET interface is also available.
Visual signals for the respective keys to be operated facilitate
the operator guidance. For additional reliability, all of the keys
24 V PROFIBUS Audio provide tactile feedback when pressed.
The project data and device settings are saved and automati-
cally updated on a system card in the device. This system card
can be used for transferring a project to another device.
Device with 10" touch display for clear representation of complex process
pictures Reliable and secure operation
Mobile Panel 177 (left) or 277 (right) – the right model for every
application – also with PROFINET/Ethernet connection
Connection point detection STOP and acknowledgement buttons are designed with dual
circuits according to the safety regulations (EN 60204-1). This
The SIMATIC HMI Mobile Panel can be configured such that means it is possible to achieve Safety Category 3 according to
the user interface changes according to the connection point. EN 954-1.
The connection point is clearly detected when the Mobile
Panel is plugged into the connection box. This enables machine- Connection at one point of the machine
specific HMI authorizations or actions to be performed de-
pending on the selected connection point. The "Basic" connection box is used for connecting SIMATIC
HMI Mobile Panels with STOP button to one point of the plant.
Integrated interfaces The disconnection of the device in this case causes an opening
of the emergency stop circuit and thus triggers the
Mobile Panels are available with PROFIBUS and PROFINET/ emergency stop.
Ethernet connection. The connecting cable can be up to 25
meters long. The interfaces are already integrated and a vari- Variable connection to different stations of a machine or
ety of drivers – even for non-Siemens PLCs – are also included plant
in the scope of supply. The PROFINET connection boxes can be
connected in series with integrated switches. If you use a Mobile Panel with STOP button together with a
connection box "Plus", a configuration can be set up in which
Sophisticated safety concept the Mobile Panel can be used at different connection points.
SIMATIC HMI Mobile Panels offer the option of making safety When the Mobile Panel is connected, the device is looped into
functions available on a mobile basis at any point of a machine or the emergency stop circuit. The emergency stop circuit re-
plant. They have two acknowledgement buttons with three mains closed regardless of whether the Mobile Panel is
switching stages which ensure the protection of personnel and plugged in or disconnected. If the Mobile Panel is disconnect-
machines in critical situations (dead man's switch). The acknowl- ed during operation, the emergency stop circuit in the Plus
edgement buttons are integrated into the handle on the back. connection box is automatically closed which prevents trig-
gering of the emergency stop circuit.
Device versions with an additional STOP button can be inte-
grated into the emergency stop circuit of a machine or plant by The Plus connection box is also available in a SIPLUS extreme
means of the connection boxes. version for extreme environmental conditions (e.g. use in cor-
rosive atmosphere/with condensation).
In this way, the STOP button offers the functionality of an emer- Further information: www.siemens.com/siplus-extreme
gency stop button, but differs visually from conventional emer-
gency stop devices due to its gray color to avoid confusion.
$XWRPDWLFFORVLQJRIWKH(PHUJHQF\6WRSFLUFXLWE\FRQQHFWLRQER[3OXV'3RU31
0RELOH3DQHOSOXJJHGLQ (PHUJHQF\6WRSFLUFXLWFORVHG
0RELOH3DQHOGLVFRQQHFWHG (PHUJHQF\6WRSFLUFXLWFORVHG
352),1(7
352),%86
03, 0RELOH3DQHO
&RQQHFWLRQER[ ZLWK6723EXWWRQ
3OXV'3RU31
(PHUJHQF\6WRSFLUFXLW
*B67B;;B
Variable connection to different stations, using the Mobile Panel 177 on the PROFIBUS as an example
Certified safety
The SIMATIC HMI Mobile Panel 277F IWLAN has two acknowl-
edgement buttons and one emergency stop button. A fail-safe
SIMATIC F-CPU must be used to be able to utilize the safety
functions. For industrial plants, the use of SIMATIC Industrial
Wireless LAN is recommended. The suitability of the device for
particularly high safety requirements was tested and certified
G_ST80_XX_00393
3 2
by TÜV (SIL 3). The necessary radio approvals already exist for
worldwide use.
The WLAN area is the area in the plant where the operator
panel communicates with an access point over a wireless local
area network.
Due to their low weight, the fully enclosed SIMATIC HMI devic-
es can be mounted easily and quickly. The backplane can be
removed easily – e.g. for subsequent installation of cables or
replacing memory cards – and thus ensures a high degree of
service friendliness even when the device is already mounted
on the machine.
The new SIMATIC HMI Key Panels KP8 and KP8F are ideally
suited for installing into the expansion units. With their col-
ored backlit keys (5 configurable colors), they are especially
well suited for displaying machine statuses.
If long distances are required between the operating unit Via RDP – and with a non-server operating system – only one
and, for example, a Comfort Panel, SIMATIC Thin Clients operating unit can be active at a time and operate the server.
are recommended. These economical and flexible operat- In this case, all other stations display the log-in window. Citrix
ing units can also be used to access different HMI devices is frequently used with highly complex client/server architec-
or PCs over PROFINET/ Ethernet. tures.
Operation of the SIMATIC Thin Clients is realized via the
touch screen or an external keyboard or mouse connected The principle: The applications which can be accessed by the
to the USB interface. clients are defined on the server. The clients can then connect
themselves automatically to the applications released on the
Economical operator stations server.
Access to the visualization software SIMATIC WinCC is possible
Client-server architectures have become a permanent feature in the industrial environment with a SIMATIC Thin Client
of the classical IT environment. The advantage lies in the fact through protocols such as Sm@rtServer.
that the "expensive" computing performance is only required
on the servers. The low-cost clients are provided for their ap- The server can be, for example, a SIMATIC HMI Comfort Panel
plications in the network. The thin client is only used to input or a PC. Two or more thin clients can be operated depending
and output data. The actual data processing is performed by on the server's performance. The advantage: If the HMI proj-
the server. The software itself only executes on the server, so ect is changed, the modification need only be carried out once
maintenance and update costs are reduced. centrally on the server. Low-cost and flexible structures can
also be produced for SCADA applications using thin clients.
High degree of ruggedness For example, the thin client can communicate as an HMI client
with the WinCC SCADA software via RDP. A completely new
As remote operator terminal without hard disk and fan, the feature is that a SINUMERIK CNC for a machine tool can now
SIMATIC Thin Client can be operated on machines with partic- also be directly operated via a SIMATIC Thin Client.
ularly high mechanical ruggedness requirements (e.g. vibra-
tion resistance). You can find information on a version with SIMATIC Thin Client Ex
complete IP65 protection on page 20.
The SIMATIC Thin Client Ex can be connected as a thin client
Integrated communication or monitor over Ethernet at an unlimited distance from the as-
sociated computer unit.
Branched structures that cover large areas can be created and
several operator stations can be connected to one server The SIMATIC Thin Client Ex can be implemented without spe-
through direct connection of the thin clients to PROFINET/ cial measures such as costly enclosures or additional certifica-
Ethernet. tion procedures, directly in hazardous areas of Zones 1/21 and
2/22.
Thin clients usually communicate over standard protocols
such as Remote Desktop (RDP), Virtual Network Computing
(VNC), or Citrix.
Customized Automation
Perfectly tailored to individual requirements
Customer-specific products from the SIMATIC portfolio Product modifications for OEM customers
provide you with the individual adaptations and add-ons go beyond a design change. OEM products are individual so-
in the quality that you know from our standard products. lutions based on SIMATIC standard products.
For the proven standard SIMATIC products (e.g. HMI, IPC, and The adaptations of the scope of delivery and the functionality
S7), we carry out the modifications that are necessary in order of the OEM products are coordinated, specified, and imple-
to meet your requirements. This ranges from minor design mented with the customer on an individual basis. They range
modifications, hardware modifications, customer-specific from minor supplementations of the products to a completely
tests and certifications, to changes in the service, support and individually designed device with TIA integration.
logistics. Depending on the extent of the modifications, we Adaptations can be implemented by combining standard
distinguish between customer-specific design, OEM solutions, SIMATIC components all the way to individual components
and turn-key products. and software adaptations.
22 Customized Automation
© Siemens AG 2011
Customized Automation 23
© Siemens AG 2011
KTP400 Basic mono PN WinCC Comfort V11 PROFINET (10 m) SIMATIC CPU S7-1200
KTP600 Basic color PN WinCC Comfort V11 PROFINET (10 m) SIMATIC CPU S7-1200
TP700 Comfort WinCC Comfort V11 PROFINET (2 m) 1 SIMATIC HMI Memory Card 2 GB,
10 protective membranes
TP900 Comfort WinCC Comfort V11 PROFINET (2 m) 1 SIMATIC HMI Memory Card 2 GB,
10 protective membranes
TP1200 Comfort WinCC Comfort V11 PROFINET (2 m) 1 SIMATIC HMI Memory Card 2 GB,
10 protective membranes
KP400 Comfort WinCC Comfort V11 PROFINET (2 m) 1 SIMATIC HMI Memory Card 2 GB
KP700 Comfort WinCC Comfort V11 PROFINET (2 m) 1 SIMATIC HMI Memory Card 2 GB
KP900 Comfort WinCC Comfort V11 PROFINET (2 m) 1 SIMATIC HMI Memory Card 2 GB
KP1200 Comfort WinCC Comfort V11 PROFINET (2 m) 1 SIMATIC HMI Memory Card 2 GB
This brochure has given you an initial overview of the extensive SIMATIC portfolio for factory automation –
and of the advantages for you as a machine builder and plant operator. Further information on the individual
S I M A T I C
SIMATIC is a principal component of Totally Integrated Automation,
the comprehensive and integrated range of products and systems for automation:
www.siemens.com/tia
The powerful, scalable process Powerful controller based on various The distributed, modular I/O
control system for all sectors hardware platforms system for all requirements
Industrial software for maximum The comprehensive range of pro- The complete range for operator
efficiency in every phase of an auto- ducts for performing technological control and monitoring
mation project tasks
Comprehensive range of hardware The basis for customer-specific, The extensive range of products
and software products for PC-based integrated MES solutions and systems for industrial commu-
Automation nication
The seamless system for safety tech- Sensors for an enormous variety Products for industrial applications
nology that integrates smoothly and of requirements in the production in harsh ambient conditions and
completely into standard automation industry extreme environments
SIMATIC Overview 27
© Siemens AG 2011
www.siemens.com/simatic-panels
SIMATIC contacts:
www.siemens.com/automation/partner
SIMATIC HMI
Answers for industry.
SO_Panels-TD_en-neu_mit-MLFBs.fm Seite 1 Montag, 5. Dezember 2011 11:17 11
© Siemens AG 2011
at a glance
KP300 Basic KTP400 Basic KTP400 Basic KP400 Basic KTP600 Basic KTP600 Basic KTP1000 Basic TP1500 Basic
KP8 PN KP8F PN KP32F PN
mono PN mono PN color PN color PN mono PN color DP / PN color DP / PN color PN
Type of operation 3.6" Key 4" Touch+Key 4" Touch+Key 4" Key 6" Touch+Key 6" Touch+Key 10" Touch+Key 15" Touch
Function keys 8 8 32 Display FSTN LCD STN liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal
(programmable) monochrome display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), display (LCD),
4 gray levels 256 colors 256 colors 256 colors 256 colors 256 colors 256 colors
Output type
Size (in inches) 3.6“ 3.8“ 4.3“ 4.3“ 5.7“ 5.7“ 10.4“ 15.1“
LED color modes 5 (green, red, yellow, blue, white)
Resolution (W x H in pixels) 240 x 80 320 x 240 480 x 272 480 x 272 320 x 240 320 x 240 640 x 480 1024 x 768
Typical service life
MTBF10) of backlighting (in h) 50,000 30,000 50,000 50,000 50,000 50,000 50,000 50,000
Short-stroke keys 1 000 000
(in number of switching cycles) Front dimensions (in mm) 165 x 97 140 x 116 140 x 116 150 x 186 214 x 158 214 x 158 335 x 275 400 x 310
Light emitting diodes 100%
(ON period in %) Operator controls Membrane keypad Touch screen and Touch screen and Membrane keypad and Touch screen and Touch screen and Touch screen and Touch screen
4 tactile keys 4 tactile keys 8 tactile keys 6 tactile keys 6 tactile keys 8 tactile keys
Options, application
Sm@rtServer / Audit / Logon –/–/– –/–/– –/–/– –/–/– –/–/– –/–/– –/–/– –/–/–
OPC server / Internet Explorer –/– –/– –/– –/– –/– –/– –/– –/–
Order No.*) 6AV3688-3AY36- 6AV3688-3AF37- 6AV3688-3EH47- Order No.*) 6AV6647-0AH11-3AX0 6AV6647-0AA11-3AX0 6AV6647... 6AV6647... 6AV6647-0AB11-3AX0 6AV6647-0AC11-3AX0 6AV6647-0AE11-3AX0 6AV6647-0AG11-3AX0
0AX0 0AX0 0AX0 6AV6647-0AD11-3AX0 6AV6647-0AF11-3AX0
*) You will find up-to-date ordering data and prices as well as our terms of sale and 1) user-configurable 2) Device version 3) Device version DP 4) PN/DP version 5) RS232 with adapter 6) Only via PROFIBUS DP 7) Integrated Flash, expandable via memory card
delivery in the Catalog ST 80 / ST PC and on the Internet at
www.siemens.com/industrymall
SO_Panels-TD_en-neu_mit-MLFBs.fm Seite 2 Montag, 5. Dezember 2011 11:17 11
© Siemens AG 2011
KTP400 Comfort TP700 Comfort TP900 Comfort TP1200 Comfort TP1500 Comfort TP1900 Comfort TP2200 Comfort Mobile Panel 177 Mobile Panel 277 Mobile Panel Mobile Panel 277
KP400 Comfort KP700 Comfort KP 900 Comfort KP1200 Comfort KP1500 Comfort 277 (F) IWLAN V2
4" Touch+Key 7" Touch 9" Touch 12" Touch 15" Touch 19" Touch 22" Touch 6" Touch+Key 8" Touch+Key 8" Touch+Key 10" Touch
4" Key 7" Key 9" Key 12" Key 15" Key
Widescreen TFT, 16 million colors, LED backlighting STN liquid crystal display TFT liquid crystal display TFT liquid crystal display TFT liquid crystal display Display
(LCD), 256 colors (LCD) 64K colors (LCD) 64K colors (LCD) 64K colors
4.3“ 7.0“ 9.0“ 12.1“ 15.4“ 18.5“ 21.5“ 5.7“ 7.5“ 7.5“ 10.4“ Size (in inches)
480 x 272 800 x 480 800 x 480 1280 x 800 1280 x 800 1366 x 768 1920 x 1080 320 x 240 640 x 480 640 x 480 800 x 600 Resolution (W x H in pixels)
80,000 80,000 80,000 80,000 80,000 50,000 30,000 50,000 50,000 50,000 50,000 MTBF10) of backlighting (in h)
140 x 116 214 x 158 274 x 190 330 x 241 415 x 310 483 x 337 560 x 380 Diameter 245 Diameter 290 Diameter 290 Diameter 350 Front dimensions (in mm)
152 x 188 308 x 204 362 x 230 454 x 289 483 x 310
Touch screen and membrane Touch screen or Touch screen or Touch screen or Touch screen or Touch screen Touch screen Membrane keypad and Membrane keypad and Membrane keypad and Touch screen Operator controls
keypad or membrane keypad membrane keypad membrane keypad membrane keypad membrane keypad touch screen touch screen touch screen
8) Configuration with WinCC flexible 2008 or higher 9) Only monitoring mode for Mobile Panel 277F IWLAN 10) Reduction of brightness by 50%, can be extended by dimming and ProfiEnergy.
SO_Panels-TD_en-neu_mit-MLFBs.fm Seite 3 Montag, 5. Dezember 2011 11:29 11
© Siemens AG 2011
TD 200 TD 400C OP 73micro TP 177micro OP 73 OP 77A OP 77B TP 177A TP 177B TP 177B OP 177B TP 277 OP 277
Keys Keys 3" Key 6" Touch 3" Key 4.5" Key 4.5" Key 6" Touch 4" Touch + Key 6" Touch 6" Touch + Key 6" Touch 6" Key
Display STN display, (with STN display, (with STN liquid crystal STN liquid crystal STN liquid crystal STN liquid crystal STN liquid crystal STN liquid crystal TFT widescreen STN liquid crystal STN liquid crystal TFT liquid crystal TFT liquid crystal
backlighting) backlighting) display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), 4 blue display (LCD), 4 blue display (LCD), display (LCD),
monochrome 4 blue levels monochrome monochrome monochrome 4 blue levels 256 colors levels or 256 colors levels or 256 colors 256 colors 256 colors
Size (in inches) 2 lines 4 lines 3" 5.7" 3" 4.5" 4.5" 5.7" 4.3“ 5.7" 5.7" 5.7" 5.7"
Resolution (W x H in pixels) Max. 20 characters/line 16 or 24 characters/ 160 x 48 320 x 240 160 x 48 160 x 64 160 x 64 320 x 240 480 x 272 320 x 240 320 x 240 320 x 240 320 x 240
Character height 5 mm line
MTBF10) of backlighting (in h) 50,000 50,000 100,000 50,000 100,000 100,000 100,000 50,000 30,000 50,000 50,000 50,000 50,000
Signaling system (number 80 80 250 / 32 500 / 32 500 / 32 1000 / 32 1000 / 32 1000 / 32 2000 / 32 2000 / 32 2000 / 32 4000 / 32 4000 / 32
of messages/message classes)
Process pictures 64 64 250 250 500 500 500 250 500 500 500 500 500
Variables 864 864 500 250 1000 1000 1000 500 1000 1000 1000 2048 2048
Vector graphics – – – • – – – • • • • • •
Bar graphs / curve diagrams –/– –/– •/– •/• •/– •/– •/– •/• •/• •/• •/• •/• •/•
Faceplates – – – – – – – – – – – – –
Recipes – – – – – 5 100 5 100 100 100 300 300
Archiving – – – – – – – – – – – • •
Visual Basic Scripts – – – – – – – – – – – • •
Programming device functions – – – – – – – – with SIMATIC S5/S7 with SIMATIC S5/S7 with SIMATIC S5/S7 with SIMATIC S5/S7 with SIMATIC S5/S7
Connection to controller
SIMATIC S7 / SIMATIC WinAC S7-200 S7-200 S7-200 S7-200 •/• •/• •/• •/• •/• •/• •/• •/• •/•
SIMATIC S5 / SIMATIC 505 – – – – –/– –/– •/• –/– •6) / • •6) / • •6) / • •6) / • •6) / •
SINUMERIK / SIMOTION – – – – –/– –/– –/– –/– •/• •/• •/• •/• •/•
Allen Bradley / Mitsubishi – – – – –/– •/– •/• •/– •/• •/• •/• •/• •/•
Modicon/Omron – – – – – – •/• – •/• •/• •/• •/• •/•
Engineering software Micro/WIN V4.0 Micro/WIN V4.0 SP 6 WinCC flexible Micro, Compact, Standard, WinCC Comfort V11 or higher, WinCC flexible Compact, Standard, WinCC Comfort V11 or higher, WinCC flexible Compact, Standard, Advanced WinCC Comfort V11 or higher,
Advanced Advanced WinCC flexible Standard, Advanced
Options, application
Sm@rtService / Sm@rtAccess / –/–/–/– –/–/–/– –/–/–/– –/–/–/– –/–/–/– –/–/–/– –/–/–/– –/–/–/– •4)/ •4) / – / • •4)/ •4) / – / • •4)/ •4) / – / • •/•/•/• •/•/•/•
Audit / Logon
OPC server / Internet Explorer –/– –/– –/– –/– –/– –/– –/– –/– –/– –/– –/– –/– –/–
Order No. *) 6ES7272-0AA30- 6AV6640-0AA00- 6AV6640-0BA11- 6AV6640-0CA11- 6AV6641-0AA11- 6AV6641-0BA11- 6AV6641-0CA01- 6AV6642-0AA11- 6AV6642-0BD01- 6AV6642-0BA01-1AX1 6AV6642-0DA01-1AX1 6AV6643-0AA01-1AX0 6AV6643-0BA01-1AX0
0YA1 0AX1 0AX0 0AX1 0AX0 0AX1 0AX1 0AX1 3AX0 6AV6642-0BC01-1AX1 6AV6642-0DC01-1AX1
*) You will find up-to-date ordering data and prices as well as our terms of sale and 1) user-configurable 2) Device version 3) Device version DP 4) PN/DP version 5) RS232 with adapter 6) Only via PROFIBUS DP 7) Integrated Flash, expandable via memory card
delivery in the Catalog ST 80 / ST PC and on the Internet at
www.siemens.com/industrymall
SO_Panels-TD_en-neu_mit-MLFBs.fm Seite 4 Montag, 5. Dezember 2011 11:29 11
© Siemens AG 2011
6" Touch 8" Touch 10" Touch 8" Key 10" Key 12" Touch 12" Key 15" Touch 19" Touch 10" Touch 15" Touch
TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT liquid crystal TFT, 64K colors TFT, 64K colors Display
display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), display (LCD), display (LCD),
64K colors 64K colors 64K colors 64K colors 64K colors 64K colors 64K colors 64K colors 64K colors
5.7" 7.5" 10.4" 7.5" 10.4" 12.1" 12.1" 15" 19" 10" 15" Size (in inches)
320 x 240 640 x 480 640 x 480 640 x 480 640 x 480 800 x 600 800 x 600 1024 x 768 1280 x 1024 325 x 263 400 x 310 Resolution (W x H in pixels)
50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 50,000 MTBF10) of backlighting (in h)
–/– –/– –/– 26 / 38 36 / 38 –/– 36 / 38 –/– –/– –/– –/– Function keys (programmable) /
System keyboard
Usable memory
2 MB 6 MB 6 MB 6 MB 6 MB 12 MB 12 MB 12 MB 12 MB – – User memory
– / 32 KB 1024 KB / 64 KB 1024 KB / 64 KB 1024 KB / 64 KB 1024 KB / 64 KB 12 MB / 128 KB 12 MB / 128 KB 12 MB / 128 KB 12 MB / 128 KB – – Memory for options / recipes
• • • • • • • • • – – Message buffer
Interfaces
•5) / • / • / • •5) / • / • / • •5) / • / • / • •5) / • / • / • •5) / • / • / • •5) / • / • / • •5) / • / • / • •5) / • / • / • •5) / • / • / • –/–/–/ –/–/–/ Serial / MPI / PROFIBUS DP/
1 x Ethernet (RJ45) 1 x Ethernet (RJ45) PROFINET (Ethernet)
• • • • • • • • • 1x 1x USB
– /• / • – /• / • –/•/• –/•/• –/•/• •/•/• •/•/• •/•/• •/•/• –/–/– –/–/– Slot for CF / Multi Media / SD
Configuration with WinCC flexible Configuration with Sm@rt Access Functionality
2000 / 32 4000 / 32 4000 / 32 4000 / 32 4000 / 32 4000 / 32 4000 / 32 4000 / 32 4000 / 32 SIMATIC Thin Clients – Low-cost on-site Signaling system (number of
operator stations messages/message classes)
500 500 500 500 500 500 500 500 500 • WinCC, installed on server systems, can be dis- Process pictures
played and operated by means of the Remote
1000 2048 2048 2048 2048 40968) 40968) 40968) 40968) Desktop Protocol (RDP). Thin clients with com- Variables
• • • • • • • • • plete IP65 protection permit operator control Vector graphics
and monitoring outside of the control cabinet.
•/• •/• •/• •/• •/• •/• •/• •/• •/• • WinCC flexible, installed on SIMATIC Multi Bar graphs / curve diagrams
– • • • • • • • • Panels or SIMATIC PCs, can be displayed and Faceplates
operated on site on thin clients by means of the
100 300 300 300 300 500 500 500 500 Sm@rtAccess option. Recipes
– • • • • • • • • • Access to HTML pages on the web is possible by Archiving
means of the integrated browser. Thin clients
– • • • • • • • • can thus be used as additional web terminals for Visual Basic Scripts
with SIMATIC S7 with SIMATIC S5/S7 with SIMATIC S5/S7 with SIMATIC S5/S7 with SIMATIC S5/S7 with SIMATIC S5/S7 with SIMATIC S5/S7 with SIMATIC S5/S7 with SIMATIC S5/S7 Intranet/Internet applications. Programming device functions
Connection to controller
•/• •/• •/• •/• •/• •/• •/• •/• •/• S7 modular embedded Controller SIMATIC S7 / SIMATIC WinAC
•6) / • •6) / • •6) / • •6) / • •6) / • •6) / • •6) / • •6) / • •6) / • – – SIMATIC S5 / SIMATIC 505
•/• •/• •/• •/• •/• •/• •/• •/• •/• •/• •/• SINUMERIK / SIMOTION
•/• •/• •/• •/• •/• •/• •/• •/• •/• – – Allen Bradley / Mitsubishi
•/• •/• •/• •/• •/• •/• •/• •/• •/• – – Modicon/Omron
WinCC Comfort V11 or WinCC Comfort V11 or higher, WinCC flexible Standard, Advanced WinCC Comfort V11 or higher, WinCC flexible Standard, Advanced – – Engineering software
higher, WinCC flexible, Com-
pact, Standard, Advanced
Options, application
•/•/–/• •/•/•/• •/•/•/• •/•/•/• •/•/•/• •/•/•/• •/•/•/• •/•/•/• •/•/ •/• – – Sm@rtService / Sm@rtAccess /
Audit / Logon
–/– •/• •/• •/• •/• •/• •/• •/• •/• – – OPC server / Internet Explorer
6AV6642-0EA01-3AX0 6AV6643-0CB01-1AX1 6AV6643-0CD01-1AX1 6AV6643-0DB01-1AX1 6AV6643-0DD01-1AX1 6AV6644-0AA01-2AX0 6AV6644-0BA01-2AX1 6AV6644-0AB01-2AX0 6AV6644-0AC01-2AX1 6AV6646-0AA21-2AX0 6AV6646-0AB21-2AX0 Order No. *)
8) Configuration with WinCC flexible 2008 or higher 9) Only monitoring mode for Mobile Panel 277F IWLAN 10) Reduction of brightness by 50%, can be extended by dimming and ProfiEnergy.
© Siemens AG 2011
www.siemens.com/simatic-panels
SIMATIC contacts:
www.siemens.com/automation/partner