You are on page 1of 2
188 BASIC SHOP PR. aia PRACTICAL 8.35 Aim. To control one lamp from two switches in conduit wiring. (Stair case wiring). Introduction. It is for practice in conduit wiring. i is 2m ——}—— .3m_ - snieei| i (ue (/8) | eet 4. i rig. 849, Wing Diagram ‘Tools. 1, Combination pliers-15 cm. 2. Side cutter-10 cm 3. Measuring tape-(scale)-1 metre. 4. Hacksaw frame with blade 30 mm-1. No. 5. Conduit die set 20 mm -1 No. 6. Round and half round file 30 cm-One each 7. Oil cane with oil 8. Pipe wrench 9, Screw driver-15-20 cm. 10. Connector screw driver. ‘Materials. 1. Conduit pipe 10 mm heavy gauige-1.6 metres 2. Junction box three-way 19 mm-1 Nos, 3.Bend 19 mm-1 No. 4. Junction box one-way 19 mm-3 Nos. 5. Bakelite batten holder-1 No. 6, $.P. One Way switch, 5A 250 V-2 Nos. 7. Conduit saddle 19 mm-1.Nos. 8. Machine screw 3/16” x 25 mm_6 Nos. 9. PVC. wire 1.5 mm?§ metres. 10. G.L. wire 1.4 S.W.G.-I metre. 11. Wood screw 12 mm, 20 mm, 30 mm. 12. Electric lamp 100 watt 13, Fish or steel wire. Procedure. 1. Make the circuit diagram and get it checked. 2. Make the layout diagram on the board with chalk. . 3. Make the wooden cleats equal to the size of saddle to be used. 4. Make two holes in them and fix them on the board at the proper place where you want to fix saddles. (t should be at a distance of 30 em on the board only). 5. Cut the pipe into measured pieces (according to the layout scale). Make threads on both sides of each piece. Clean all the pieces with cotton waste. 6. Fix the junction box. Tees and bends. 7. Insert the wires with the help of fish wire, ie, steel wire. Earth wire should also 8. Fix the whole frame with saddles on the gutties already fixed. 9. Fix the necessary switches and holder. 10. Test the supply with sereis testing board. g0 through the pipe. 0989 \WIRING-CLEAT, BATTEN, CASING CAPPING AND CONDUIT Precautions. 1. There should not be any burrs atthe end of the pipe piece. 2. In the pipe there should not be any twist in wires, z . Keep extra allowance of wires in each junction box. x |. Threads on pipe should be only 12 mm in length size so that it may fit it in junction box ete. Full wiring pipe should be well earthed, ‘There should not be any naked wire in the pipe, Examiner may ask you. Same as in Practical 8.34. | PRACTICAL 8.36 } ‘Aim. To control one lamp from three | places by using two ‘two-way switches’ and one intermediate switch in conduit pipe wiring. Introduction. This circuit is used for a3 storied building which has long and straight staircase. OR it is used in a long | corridor OR a godown which has three doors | and a person may come from any door and light the lamps and can go from any door by closing the switch Tools. 1. Combination pliers 15 em-1 No. 2, Side cutter 15 cm-I No, 3 Screw driver 15 em-1 No: 4. Connectors screw driver 10cm-1 No, 5. Electrician knife 10 cm-I No. 6. Drill machine-1. 7. Seale. | 8. Halfround and round file 30 cm-I each 9. ‘Conduit die set with cutters 19 mm-I set. 10. Pipe wrench. 11. Chalk. 12. Hacksaw blade in frame. Materials 1. Conduit pipe 19 mm heavy gauge-I.9 metres. 2. Junction box four way 19 mm= 1 No. 3. 4 s. 6 }. Inspection type Tee 19 mm-1 No, |. Bend 19 mm-1 No. . Junction box one-way ~4 Nos. Conduit saddle 19 mm-14 Nos. . Bakelite batten holder-1 No. SP. one-way switch 5 A 250 Volts -4 Nos. . Intermediate switch-1 No. 10. Machine screw 5 mm x 25 mm-8 Nos. 11. PV.C. wire 1.5 mm? 250 V-6 metres. 12. Wooden bush 19 mm-9 Nos, 13, GL. Wire 16 S.W.G.-1 metre. 14, Wood screw-12 mm, 20 mm, 30 mm, Procedure. As per practical No. 8.34, Precautions. As per practical No. 8.34, Re The Thur

You might also like