Professional Documents
Culture Documents
SPESIFIKASI TEKNIK
I. MASTER STATION
Server Concentrated with
1 Server Concentrated Server Distributed
DELL PowerEdge R750
8 SFF SAS/SATA
8 SFF SAS/SATA
HDD Bays;
Internal Internal HDD Bays; includes 8 SFF SAS/SATA HDD Bays;
includes 6 SFF
Strorage Strorage 6 SFF hard drive includes 6 SFF
blanks
hard drive blanks
3 PCIe slots (+3 3 PCIe slots (+3 Up to 8 x PCIe Gen4 slots (up to
PCI Express PCI Express
PCI slots available PCI slots available 6 x16) with support for SNAP I/O
Slot Slot
with upgrade option) with upgrade option) modules
Redundancy (2 x
Redundancy (2 x
800 Watt FS
Power 800 Watt FS Redundancy (2 x 800 Watt FS
Power Supply Platinum Hot
Supply Platinum Hot Plug Platinum Hot Plug Power Supply)
Power Supply)
Plug Power Supply)
I. MASTER STATION
2 Dispatcher Workstation DELL Precision 7820
Intel Xeon Silver 4112
Intel® Xeon® 4112, Intel® Xeon® 4112, 2.6GHz,(3.0GHz Turbo, 4C,
Processor Processor
2.6GHz 2.6GHz 9.6GT/s 2UPI, 8.25M Cache, HT
(85W)DDR4-2400)
1x32 GB DDR4 1x32 GB DDR4 32GB (2X16GB) DDR4 3200MHZ
Memory Memory
ECC DDR ECC DDR RDIMM ECC memory
2x10/100/1000Mbps (LAN
Network 2x10/100/1000Mbp Network 2x10/100/1000Mbps
TEAM)
s (LAN TEAM) (LAN TEAM)
Hard Drive 1000GB SATA Hard Drive 1000GB SATA 1TB SATA
NVIDIA NVIDIA
NVIDIA QuadroP1000 4 GB (Up
Graphic Card QuadroP1000 4 GB Graphic Card QuadroP1000 4 GB
to 4 Display)
(Up to 4 Display) (Up to 4 Display)
2x10/100/1000Mbps (LAN
Network 2x10/100/1000Mbp Network 2x10/100/1000Mbps
TEAM)
s (LAN TEAM) (LAN TEAM)
Hard Drive 1000GB SATA Hard Drive 1000GB SATA 1TB SATA
NVIDIA NVIDIA
NVIDIA QuadroP1000 4 GB (Up
Graphic Card QuadroP1000 4 GB Graphic Card QuadroP1000 4 GB
to 4 Display)
(Up to 4 Display) (Up to 4 Display)
8x DVD+/-RW 9.5mm Optical
DVD ROM DVD+/- RW DVD ROM DVD+/- RW
Disk Drive
USB KB/Mouse USB KB/Mouse KB/Mouse
I. MASTER STATION
4 HMI DELL Precision 7820
Processor Core i7-9700 Processor Core i7-9700 Intel Core i7-9700
Memory 8GB DDR4 Memory 8GB DDR4 8GB DDR4
1x10/100/1000Mbps (LAN
Network 1x10/100/1000Mbp Network 1x10/100/1000Mbps
TEAM)
s (LAN TEAM) (LAN TEAM)
Hard Drive 1TB HDD Hard Drive 1TB HDD 1TB HDD
Intel UHD Graphic Intel UHD Graphic
Graphic Card Graphic Card Intel UHD Graphic 630
630 630
8x DVD+/-RW 9.5mm Optical
DVD ROM DVD+/- RW DVD ROM DVD+/- RW
Disk Drive
USB KB/Mouse USB KB/Mouse KB/Mouse
24 x RJ45 24 x RJ45
10/100/1000Base-T 10/100/1000Base-T 24 x RJ45 10/100/1000Base-T (X)
Connector (X) Ethernet 4x Connector (X) Ethernet 4x Ethernet 4x RJ45/SFP combo
RJ45/SFP combo RJ45/SFP combo ports (optional)
ports (optional) ports (optional)
SFP
SFP (optional) Link / Activity Link / Activity Link / Activity
(optional)
Console Port RS-232 ( RJ45 ) Console Port RS-232 ( RJ45 ) RS-232 ( RJ45 )
I. MASTER STATION
IP Access security,
IP Access security,
port security, DHCP IP Access security, port
port security, DHCP
client, Port and IP security, DHCP client, Port and
Security Security client, Port and IP
Binding, 802.1X IP Binding, 802.1X Port Access
Binding, 802.1X Port
Port Access Control,
Access Control,
Control,
I. MASTER STATION
Active cooling by Active cooling by
Active cooling by fans,
fans, temperature- fans, temperature-
Cooling Cooling temperature-controlled. Air inlets
controlled. Air inlets controlled. Air inlets
left/right
left/right left/right
Via keypad and Via keypad and
Via Web, keypad and LCD-
Operation LCD-Display Operation LCD-Display
Display (Illuminated)
(Illuminated) (Illuminated)
GPS Data
L1 frequency L1 frequency
Evaluation Evaluation L1 frequency (1575.42 MHz)
(1575.42 MHz) (1575.42 MHz)
Backup Clock
I. MASTER STATION
Signal Output (External)
Standard/Maximum Standard/Maximum:
Memory Memory Standard/Maximum: 128 MB
: 128 MB 128 MB
Processor Processor
1200 MHz 1200 MHz 1200 MHz
Speed Speed
Function Print,Scan,Copy Function Print,Scan,Copy Print,Scan,Copy
I. MASTER STATION
9 Monitor/VDU Dell 24 Monitor - P2422H
Ukuran 23,8 Ukuran 23,8 24 inch
Tipe Panel IPS Tipe Panel IPS IPS
Aspect Ratio 16.09 Aspect Ratio 16.09 16:09
Resolution 1920 x 1080 Resolution 1920 x 1080 1920 x 1080 at 60 Hz
Brightness 250 Brightness 250 250 cd/m² (typical)
Surface Surface
Anti-Glare, 3H Anti-Glare, 3H Anti-Glare
Treatment Treatment
Height adjustability stand 150
Base Detachable, Base Detachable, mm
Stand Tilt (-5° s.d. 22° Stand Tilt (-5° s.d. 22° Tilt -5° to 21°
Vertical) Vertical) Swivel -45° to 45°
Pivot -90° to 90°
10 Console Desk Local
I. MASTER STATION
13 Rak Server APC NetShelter SX 42U
Maximum Maximum
1991MM, 199.1CM 1991MM, 199.1CM 1991MM, 199.1CM
Height Height
Maximum Maximum
600MM, 60.0CM 600MM, 60.0CM 600MM, 60.0CM
Width Width
Maximum Maximum
1070MM, 107.0CM 1070MM, 107.0CM 1070MM, 107.0CM
Depth Depth
14 Rak Workstation APC NetShelter SX 42U
Maximum Maximum
1991MM, 199.1CM 1991MM, 199.1CM 1991MM, 199.1CM
Height Height
Maximum Maximum
600MM, 60.0CM 600MM, 60.0CM 600MM, 60.0CM
Width Width
Maximum Maximum
1070MM, 107.0CM 1070MM, 107.0CM 1070MM, 107.0CM
Depth Depth
15 Wall Display LG 55SVM5F
INPUT
External RS232C (1), RJ45 External RS232C (1), RJ45 RS232C In/out, RJ45 (LAN)
Control (1), IR Receiver (1) Control (1), IR Receiver (1) In/out, IR In
I. MASTER STATION
16 Video Wall Controller
Input 16 HDMI Input 16 HDMI 16 input HDMI
Output 17 HDMI Output 17 HDMI 20 Out HDMI
18 Backdrop Panel
Bahan HPL Bahan HPL
Motif Serat Kayu Motif Serat Kayu
Warna Gelap Warna Gelap
19 HDMI Kabel 15M Kramer Cable HDMI / 10m
Konektor Male - Male Konektor Male - Male
30+28+26AWG 30+28+26AWG
Fiber Optical (AAZ) Fiber Optical (AAZ)
& Tinned Copper + & Tinned Copper +
Konduktor Fiber Optical (AAY) Konduktor Fiber Optical (AAY)
Mengikuti kebutuhan Controller
& Fiber Optical & Fiber Optical
dan wall display
(AAE), Standard (AAE), Standard
19pin 19pin
I. MASTER STATION
Kebutuhan untuk Instalasi Master Kebutuhan untuk Instalasi Master Sesuai Kebutuhan Master
Station Station Station
I. MASTER STATION
24 Grounding dan Accessories
Standart Sesuai SNI Standart Sesuai SNI Sesuai SNI
Lebar Lebar
4 mm 4 mm 4 mm
Penampang Penampang
Grounding
Grounding Rod 1 m (Full Cu) 1 m (Full Cu) 1 m (Full Cu)
Rod
25 LVMDB dan Accessories
Poles 3 Poles Poles 3 Poles
Rated
Rated Current 100A at 65 Degree 100A at 65 Degree 100A at 65 Degree
Current
10 kA at 600 V AC 10 kA at 600 V AC
short-circuit short-circuit
50/60 Hz 50/60 Hz 10 kA at 600 V AC 50/60 Hz
breaking breaking
conforming to UL conforming to UL conforming to UL 508
capacity capacity
508 508
Kebutuhan untuk Instalasi Master Kebutuhan untuk Instalasi Master Kebutuhan untuk Instalasi
Station Station Master Station
1x10/100/1000Mbp 1x10/100/1000Mbps
1x10/100/1000Mbps Ethernet
Network s Ethernet Network Ethernet
I. MASTER STATION
Intel Dual Band Wi- Intel Dual Band Wi-
Intel Dual Band Wi-Fi 6 AX201
Fi 6 AX201 2x2 Fi 6 AX201 2x2
Port Port 2x2 802.11ax 160MHz +
802.11ax 160MHz 802.11ax 160MHz +
Bluetooth 5.1
+ Bluetooth 5.1 Bluetooth 5.1
3Yr 3Yr
ProSupport:Next ProSupport:Next 3Yr ProSupport:Next Business
Garansi Garansi
Business Day Business Day Day Onsite Service
Onsite Service Onsite Service
Firewall Firewall
Throughput Throughput
(1518/512/64 7.4/7.4/4.4 Gbps (1518/512/64 7.4/7.4/4.4 Gbps 7.4/7.4/4.4 Gbps
byte UDP byte UDP
Package) Package)
Firewall Firewall
3 μs 3 μs 3 μs
Latency Latency
Maximum Maximum
number of number of
24 24 24
switches switches
support support
Maximum Maximum
number of number of
600 600 600
registered registered
clients clients
Form Factor Rack Mount (1RU) Form Factor Rack Mount (1RU) Rack Mount (1RU)
I. MASTER STATION
30 Projector EPSON EB-W41
Projection Projection
Up to 320 inch Up to 320 inch Up to 320 inch
Screen Screen
Projection 60" screen 1.68 - Projection 60" screen 1.68 -
60" screen 1.68 - 2.02 m
Distance 2.02 m Distance 2.02 m
Light Output 3600 Lumens Light Output 3600 Lumens 3600 Lumens
JASA
Instalation Instalation
1 Biaya Jasa Instalasi Biaya Jasa Instalasi Biaya Jasa Instalasi
Service Service
Video Wall Biaya Jasa Instalasi Video Wall Biaya Jasa Instalasi
3 Biaya Jasa Instalasi Video Wall
Instalation Video Wall Instalation Video Wall
REMOTE STATION
II. GARDU INDUK
JASA
Testing & Biaya Jasa Testing & Biaya Jasa Testing & Komisioning
1
Commisioning (Sisi TT) Komisioning (Sisi TT) (Sisi TT)
Biaya Jasa Integrasi dan
Biaya Jasa Integrasi dan Mapping
2 Mapping SAS (Sisi TT) Mapping Getaway SAS
Getaway SAS hingga IED
hingga IED
Jaminan ketersediaan peralatan yang Surat Pernyataan Puas dari Comply, refer to SCADA
tinggi User Existing Solutions Brochure
Surat Pernyataan Puas dari Comply, refer to SCADA
Jaminan keandalan yang tinggi
User Existing Solutions Brochure
Surat Pernyataan Puas dari Comply, refer to SCADA
Jaminan kemudahan dalam operasi
User Existing Solutions Brochure
Jaminan kemudahan dalam Surat Pernyataan Puas dari Comply, refer to SCADA
pemasangan dan pemeliharaan User Existing Solutions Brochure
Jaminan keamanan untuk fungsi Surat Pernyataan Puas dari Comply, refer to SCADA
kontrol User Existing Solutions Brochure
Jaminan kemudahan dalam Surat Pernyataan Puas dari Comply, refer to SCADA
modifikasi dan/atau pengembangan User Existing Solutions Brochure
Surat Pernyataan Puas dari Comply
Jaminan Open System
User Existing
Kriteria dasar yang harus
2 dipenuhi minimal adalah sebagai
berikut:
Dilengkapi dengan Real-Time
Database Management System,
dengan :
Comply, dbresize can be
1. Poin tidak terbatas
performed to adjust Point size.
Comply, dbresize can be
2. Pengguna SCADA tidak terbatas
performed to adjust Point size.
Akses dengan data historikal dapat Comply, Historian is based on
dilakukan dengan menggunakan SQL
(Standard Query Language)
Komunikasi dengan RTU Comply, refer to SCADA
Protocol : Solutions Brochure
1. IEC 101
2. IEC 104
3. DNP3
4. Modbus
Komunikasi RTU ke IED Comply
Protocol :
1. IEC 101
2. IEC 104
3. DNP3
4. Modbus
5. IEC 61850
Real-time Database
Comply, refer to SCADA
Untuk keperluan proses dan
Solutions Brochure
penyimpanan data operasioanal
Sistem SCADA digunakan database
real-time. Data hasil akuisisi dari RTU
maupun data-data yang dimasukkan
secara manual kedalam aplikasi
Sistem SCADA disimpan dalam
database real-time untuk dilakukan
pemrosesan. Disain dari database
real-time ini harus dapat memenuhi
kriteria unjuk-kerja (performance)
Pemeliharaan Data
Pemeliharaan data dalam database Comply, refer to SCADA
real-time harus dapat dilakukan Solutions Brochure
secara on-line. Rekanan harus
membuktikan bahwa pada waktu
pemeliharaan database, operasional
Sistem SCADA tidak mengalami
gangguan dan adanya kehilangan
informasi. Untuk keperluan tracing,
maka seluruh aktifitas ini harus di-
audit dan direkam.
PIHAK KEDUA _________________ PIHAK PERTAMA _________________
48 dari 69
No PERSYARATAN KETERANGAN PROPOSED & GUARANTEE
Pengubahan Data
Perubahan data dalam database real- Comply, refer to SCADA
time dapat dilakukan secara on-line Solutions Brochure
tanpa mengganggu proses operasi
SCADA.
Sebagai contoh, pada saat Comply, refer to Database
pemasangan RTU baru maka Update Sequence User Guide
penambahan RTU baru tersebut
kedalam Sistem SCADA dapat
dilakukan secara on-line tanpa
menghentikan (halt) operasi Sistem
SCADA. Jika terjadi kegagalan
validasi data RTU baru, maka data
sebelumnya harus dapat segera
diaktifkan untuk keperluan
operasional.
Struktur Database
Untuk memperoleh keterbukaan Comply, refer to Source
Sistem SCADA, maka seluruh Documentation
database guna keperluan operasi
harus dapat dipelihara dan diubah
melalui SQL.
Comply, refer to Source
Struktur Database dapat
Documentation
dikembangkan melalui SQL, demikian
pula mengedit prosedur yang ada
dalam Sistem SCADA, sehingga file
data, arsip, dan fungsi yang akan
ditambahkan oleh PLN di masa yang
akan datang dapat diintegrasikan
tanpa menuntut persandian (coding)
database tambahan. Rekanan harus
memberikan cara untuk membuat,
memodifikasi, dan menghapus
struktur database secara mudah
kepada PLN. Struktur dan format
database yang akan dibangun dan
diimplementasikan harus dimintakan
persetujuan dan direview oleh PLN.
Historical Data
Semua data hasil perubahan dalam Comply
Sistem SCADA harus disimpan
dalam suatu historical database.
Sebagai contoh, apabila terjadi
perubahan nilai pengukuran suatu
peralatan maka secara otomatis data
lama akan disimpan kedalam
historical database ini. Hal ini sangat
penting dalam melakukan tracing dan
analisa apabila terjadi suatu
gangguan pada jaringan listrik.
22 Alarm Inhibit/Enable
Inhibiting alarm suatu nilai atau Comply
peralatan akan menyebabkan proses
alarm (nilai atau perangkat) yang
bersangkutan dihilangkan. Akan
tetapi scaning (pembacaan) dari nilai
dan perangkat tersebut tetap
dilakukan dan databasenya tetap
diupdate.
Inhibiting alarm akan menyebabkan Comply
hal sebagai berikut:
Peniadaan semua alarm yang Comply
berkaitan dengan nilai dan peralatan
tersebut
Penambahan record pada Alarm Comply
Inhibit Summary Record
Comply
Untuk membedakan alarm
unacknowledge maka alarm ini harus
diberi warna yang berbeda. Dari alarm
summary ini dimungkinkan bagi
operator untuk mencari dan
mendisplaykan peralatan yang
menimbulkan alarm tersebut.
36 Help Displays
Untuk membantu operator, Sistem Comply
SCADA harus dilengkapi dengan
fasilitas offline help. Fasilitas secara
offline akan membantu operator
dalam mengintepretasikan informasi
serta memandu operator melalui
informasi yang diberikan disetiap
tampilan maupun dalam pada waktu
melaksanan proses pengontrolan.
Setiap tampilan mempunyai target- Comply
kursor sehingga operator dapat
dengan mudah memilih target yang
diinginkan di offline Help Display
tersebut. Fasilitas Help Display ini
dapat dengan mudah diubah oleh
Software Engineer.
37 Pelaporan
Sistem SCADA harus dilengkapi Comply
dengan fungsi pembuatan pelaporan
seperti operational report,
performance report dan summary
report. Pembuatan laporan dapat
dilakukan secara periodik maupun
sesuai dengan keinginan operator.
Comply
Periodic reports harus dapat
dilakukan secara berkala untuk setiap
jam, harian, bulanan atau tahunan
sesuai keperluan PLN. Setiap laporan
berkala (periodic report) dapat dicetak
atas permintaan operator.
Comply
Dengan query yang didefinisikan
sebelumnya untuk penyimpanan data
(archive filter), untuk mendefinisikan
pilihan dengan rentang waktu yang
berbeda, siklus penyimpanan dan
nilai penandaan yang berbeda.
47 AM / FM / GIS Interface
Sistem SCADA yang ditawarkan Partialy Comply, supported by
harus mampu meng-import data dari DXF to DDL Tool.
sistem AM/FM/GIS. Data grafis dan
atribut database harus dapat diimport
melalui format standar seperti
Intergraph, ARC / INFO, SICAD,
Autocad, atau DXF format
Proses import data harus secara Comply, database modeling
otomatis dapat dilakukan melalui environment support import from
suatu interface yang disediakan CIM, Excel, and csv Format
sehingga hasil import data tersebut
dapat dibaca secara langsung oleh
sistem SCADA.
49 Rekontruksi Kejadian
Sistem SCADA harus mampu Comply, refer to SCADA
melakukan rekontruksi kejadian pada Solutions Brochure. (Historical
alarm sehingga memudahkan Data Recording)
operator dalam menganalisa suatu
kejadian dalam bentuk Playback
50 Perintah Sequence
Comply, refer to SCADA
Sistem SCADA harus mampu
Solutions Brochure (Control
menjalankan perintah sequence
Sequence Scheduler)
52 Network Colouring
Aplikasi ini akan memudahkan Comply, supported by
operator untuk mengetaui konektifitas SCADATOP Application
kelistrikan jaringan yang menjadi
wilayah kerjanya. Dengan aplikasi ini
operator dengan cepat mengetahui
daerah mana saja yang mengalami
gangguan, atau operator dengan
cepat mengetahui dari feeder mana
daerah tersebut mendapatkan supply
listriknya
Dengan aplikasi ini sistem SCADA Comply, supported by
yang ditawarkan harus mampu SCADATOP Application
menampilkan beberapa warna yang
berbeda sehingga operator dapat
dengan cepat membedakan suatu
konektifitas kelistrikan yang terjadi
baik secara real-time maupun off-line
Network coloring minimal harus Comply, supported by
mampu memberikan ditail pewarnaan SCADATOP Application
kondisi berikut:
Comply, supported by
Energised
PIHAK KEDUA _________________ SCADATOP Application
PIHAK PERTAMA _________________
Comply, supported by
De-energised 67 dari 69
SCADATOP Application
yang ditawarkan harus mampu SCADATOP Application
menampilkan beberapa warna yang
berbeda sehingga operator dapat
dengan cepat membedakan suatu
konektifitas kelistrikan yang terjadi
baik secara real-time maupun off-line
Network coloring minimal harus Comply, supported by
mampu memberikan ditail pewarnaan SCADATOP Application
kondisi berikut:
Comply, supported by
Energised
SCADATOP Application
Comply, supported by
De-energised
SCADATOP Application
Comply, supported by
Earthed
SCADATOP Application
Comply, supported by
Abnormal
SCADATOP Application
III. ADVANCE SCADA
1 Perangkat Lunak Networking
Networking Communications
Software
Sistem yang ditawarkan harus dapat Comply, ICCP Server is not part
dioperasikan menggunakan protokol of the delivery.
standar LAN seperti TCP/IP. Dengan
demikian semua konektifitas
perangkat keras dalam Sistem
SCADA harus melalui LAN. Dimasa
yang akan datang, Sistem SCADA
Untuk Pengembangan
tersebut harus dapat pula
(Termasuk demo Fitur Aplikasi)
diintegrasikan dengan perangkat lain
dengan menggunakan Wide Area
Network (WAN). Untuk koneksi
dengan Pusat Kontrol lain maka
protokol yang digunakan adalah
Protokol DNP3, IEC 101 dan IEC 104,
ICCP atau VRTU
DISPATCHER TRAINING
2
SIMULATOR (DTS)
Comply, refer to AEMS
Untuk keperluan pelatihan dan
Brochure. DTS Server is not part
simulasi penyelesaian gangguan,
of the delivery
sistem SCADA/EMS yang ditawarkan
mampu memenuhi pengembangan
Untuk Pengembangan
fungsi Dispatcher Training Simulator
(Termasuk demo Fitur Aplikasi)
(DTS). DTS ini akan diinstall pada
DTS server yang berada di Pusat
Kontrol RCC dan dilengkapi dengan 2
set DTS workstation.