You are on page 1of 8
FUJINON FUJIFILM ~ Endoscopic —) Ultrasonography EG-530UT = — . — 6 SU-7000 «4 Endoscopic ‘S Ultrasonography ‘The New Endoscopic Ultrasonography System from Fujinon A system that integrates ultrasonographic diagnosis and treatment, with Fujinon's high quality digital imaging. Fujinon has developed its new endoscopic ultrasonography system to meet the demands of physicians for a better gastrointestinal diagnosis and ultrasound-guided FNA system architecture We started with clear image projection, then we added features which satisfy the most stringent requirements for usability and flexibility. Finally, we combined high-quality video imaging, radial ultrasound scanning and convex ultrasound scanning into a fully integrated system, utilizing the new SU-7000 processor and the new EG-530UR and EG-530UT ultrasound endoscopes. ‘A new age in endoscopic Utrasonogrphy is born. A Compact, High-Quality, Endoscopic Ultrasonography and Video Imaging System th NM = | tu State of the Art Technology and Flexible Operation for Enhanced Diagnostic Accuracy Daevetoped specifically for ultrasonic endoscopes, the SU-7000 allows high-quality ultrasonography to be incorporated with Comprehensive Ineggated Keyboard conventional endoscopy into a single cart, “This well designed keyboard brings one the essential fintiont of the SU-7000 resulting in a highly functional, compact system. Serene Integration of Fujinon’s high-performance endoscopy with a state-of-the-art ultrasonography system allows physicians to make the best use of limited examination space without compromising diagnostic and therapeutic quality. The system offers casy keyboard operation and convenient presentation of endoscopic video and ultrasound images with the Picture-in-Picture display fanction. The SU-7000 allows the use of both radial scope and Fine Needle Aspiration (FNA) convex scope, for unsurpassed observation, diagnosis, and treatment capability. —_— Integrated Compact Flash* Media Card Slot ‘The CF card allows direct ecording and reproduction af images during examination, Post-exam transfer of images to a PC is easily accomplished with no image deterioration, — Endoscopic Ultrasonography Variable Modes The color doppler function provides hemod Imaging of organs surrounding the tegion of i ami information in diseased areas. rest and observation of vascularity, allows safer and more reliable FNA, Image processing (ur proprietary image processing eliminates blur in hyperechoic regions. Unprocessed Image Processed Image Variable Frequency Picture-in-Picture Display Function The system can precisely delineate ultrasound images in a multitude The Picture-in-Pieture display function permits of frequencies ftom 5 to 12 MHz. Thus, finely detailed images of simultaneous presentation of wo image-—an the layers of the gastric wall, as well a organs such atthe pancreas, «endoscopic video image and an ultrasonographic can be clearly delineate. image—ensuting safe opera a Superb Image Quality and Innovative Features for Unsurpassed Operability Fagjinon’s new EG-530UR and EG-530UT endoscopes combine our high-quality video endoscope features with the most advanced ultrasound technology, to create an unsurpassed diagnostic and treatment system. Handling Ability All the handling features and lightweight, ergonomic qualities of our reliable G5 endoscopes, have been incorporated in the EG-530UR and EG-530UT, to case the stress of hours of use on both the practitioner and patient. “The bending radius of these endoscopes is better than any other in theit class Asa result of the increased visualization and observation capacity, ic is possible to detect and examine previously difficule co detect lesions High Resolution Image Our high-resolution SUPER CCD chip technology provides the best in high-definition, high-resolution imaging. The real-time image can be frozen and saved asa single high-quality image. This quality is not the result of excellent resolution alone; ic is also che result of the RGB filtering capability of the Super CCD that realizes minute differences in the all-important red spectrum, providing a clear picture of tiny blood vessels. ‘Through attention to detail and the maximization of digital technology, a new era of comfort in ultrasonographic endoscopy is born. Bending Capabilty of the EG-530UR: U/D/AIL 180/90/100/100 degrees Bonding Capabilty of the EG-S00UT: LU/DI AIL. 1601160/120/120 degrees Clinical Data Endoscopic Ultrasonography EG-530UR radial scan ultrasound video endoscope (for observation) ‘The EG-53OUR, with a small outer diameter of 11.4 mm and excellent bending capabilites, allows physicians to perform endoscopic ultrasonography ina similar way ro conventional endoscopy: ‘The scope ip bending angle permite observation of previously difcul to access areas and improves screening efficiency. In combination with ultrasound images, cnndoscopi video images of high quay, capeued with our high-r , realy ad diagnosis A \ olution Super C EG-530UR, EG-530UT convex sean ultrasound video endoscope (for treatment) The thin distal up of the EG-530UT has a large channel (3.8 mm) chat permits EUS-ENA, drug injection, and passage of other therapeutic devices auch asa drainage tube, With excellns ending capabilities comparable to conventional endoscopes, the EG-530UT provides yA access to lesions and greater flexibiligy in ceatmens. EG-530UT SU-7000 Power Vorage Toro Br ‘Consumption carer [18a TOR. a ‘Size WIDE) oa, Wight 2a Crasstieaton Clase Type F Uivassund image dsplay | Probe ype Gorvox Fadl ‘Scanning mda Power Dapper Caer Depot PW Dapper TH mode TB nade THT Scanning method Elbtrons sean Dissay range Zito Frequang ES Signal processing Fae Digial aT ET STC 8 phases Teo Distaico [aren Tlie VooeIy Te Tangle Tae TSS Display Patent inermatin comment eats ime Recording "ise0, VIR, Fling Fomote conta Foot seh ‘Others PRUE PE, Solan of ARG oNASOIRS HAGE Morar card Fare EG-530UR EG-530UT. Viewing arecion Forward viewing | Forward oblique #0” [observation range ‘S=100mm ‘100mm 10 Field of view 140" 140" § [Distal ond cao ai én zis.emm 8 [Flext prton dartae 215mm 2.4mm © [Boncing capably: UPDOWN 180700" 3607160" Z LEFT RIGHT ooo" 1207120" 2 Fercops channel diameter ‘2.2mm 3.8mm 2 [Werkng wnat 125¢mm 7258nm otal erat 154mm 154mm ‘Scanning mode ‘Golo Doppler Power Dapper PW Doppler? 8 B mode M mode! THI ‘Scanning method Elector radial Elocronie convex ‘Seapning angs 10° kre Scanning area 360 inertia ol oward longue 0" the coal ax Frequeney ‘ial 7 SMAa!TOwHE Taz ‘Balloon method dagassed water congestion mathod / ‘contacting method FUJINON CORPORATION 1-324 UETAKE, KITA-KU, SAITAMA CITY, SAITAMA 991-9624, JAPAN E-MAIL: sales@msvtujinon.co,jp URL: hitp:www-tujinon.co.p FUJINON INC. 40 HIGH POINT DRIVE, WAYNE. NU 07470, U.S.A E-MAIL: med.infoafujinon.com URL: hitp/www fulinan.com FUJINON (EUROPE) GmbH TEL: 49-2154-924.0 FAX: 49-2154-924-290 E-MAIL: Fujinon@fujinen.de URL: mitprwww.tujinan.de FUJINON SINGAPORE PTE. LTD. BLK 211 HENDERSON ROAD, #10-04 HENDERSON INOUSTAIAL PARK, SINGAPORE, 159552 E-MAIL: fujinon@tujinon.com.sq URL: hitsrwww.tujinon.com.sg FUJINON AUSTRALIA PTY.LTD. E-MAIL: salos@tuinon-com.au SHANGHAI FUJINON MEDICAL EQUIPMENT CO., LTD. FLAT 8, 6/FL, SHI MEI BLD, 79 RI JING ROAD, WAI GAO GIAG FAEE TRADE ZONE, SHANGHAI, 200191 CHINA TEL 86-21-8424-9262(OHice) TEL 86-21-5866-2151(Servca) FAX: 86-21-5865-2150, E-MAIL tng200%@netmaitcom woment, specications are subject to change without notice. soe-074-00

You might also like